Search results for: dose intensity
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3124

Search results for: dose intensity

2524 [Keynote Speech]: Simulation Studies of Pulsed Voltage Effects on Cells

Authors: Jiahui Song

Abstract:

In order to predict or explain a complicated biological process, it is important first to construct mathematical models that can be used to yield analytical solutions. Through numerical simulation, mathematical model results can be used to test scenarios that might not be easily attained in a laboratory experiment, or to predict parameters or phenomena. High-intensity, nanosecond pulse electroporation has been a recent development in bioelectrics. The dynamic pore model can be achieved by including a dynamic aspect and a dependence on the pore population density into pore formation energy equation to analyze and predict such electroporation effects. For greater accuracy, with inclusion of atomistic details, molecular dynamics (MD) simulations were also carried out during this study. Besides inducing pores in cells, external voltages could also be used in principle to modulate action potential generation in nerves. This could have an application in electrically controlled ‘pain management’. Also a simple model-based rate equation treatment of the various cellular bio-chemical processes has been used to predict the pulse number dependent cell survival trends.

Keywords: model, high-intensity, nanosecond, bioelectrics

Procedia PDF Downloads 223
2523 Comparison of the Effect of Two Rootstocks Citrus Macrophylla and Citrus Volkameriana on Water Productivity of Citrus “Orogrande” Under Three Irrigation Doses

Authors: Hicham Elomari, Absa Fall, Taoufiq Elkrochni

Abstract:

This present work mainly concerns the improvement of citrus water productivity in the Souss Massa region. The objective is to evaluate the effect of deficit irrigation applied during the fruit growth stage on fruit size, quality and yield of the Orogrande variety grafted on Citrus macrophylla and Citrus volkameriana. Three irrigation regimes were adopted, a control D0 of 3.6 l/h and two doses D1 (58% D0 =2.1 l/h) and D2 (236% D0 =8.5 l/h). The experimental design was a randomized complete block while keeping the same spacing between drippers, the same duration of irrigation and the beginning of trials (fruit growth stage). Results showed that at the end of the cycle from October 1, 2020, to September 30, 2021, a total water supply of 732 mm and 785 mm using the D1 dose was provided to trees of Orogrande variety, respectively grafted on Citrus macrophylla and Citrus volkameriana rootstocks. Citrus macrophylla presented largest fruit size of 38 mm compared to Citrus volkameriana (33mm) with a significant difference. Total soluble sugar (8°Brix) and juice content level (40%) were higher with the application of the D1 dose on both rootstocks. Yield of 36 Tons was not affected by the deficit irrigation. Reduction of water supply by 18% increases agronomic productivity (6 MAD/m³) and economic productivity (3 MAD/m³).

Keywords: citrus, irrigation, fruit size, fruit quality, yield

Procedia PDF Downloads 60
2522 Characterization of Pure Nickel Coatings Fabricated under Pulse Current Conditions

Authors: M. Sajjadnejad, H. Omidvar, M. Javanbakht, A. Mozafari

Abstract:

Pure nickel coatings have been successfully electrodeposited on copper substrates by the pulse plating technique. The influence of current density, duty cycle and pulse frequency on the surface morphology, crystal orientation, and microhardness was determined. It was found that the crystallite size of the deposit increases with increasing current density and duty cycle. The crystal orientation progressively changed from a random texture at 1 A/dm2 to (200) texture at 10 A/dm2. Increasing pulse frequency resulted in increased texture coefficient and peak intensity of (111) reflection. An increase in duty cycle resulted in considerable increase in texture coefficient and peak intensity of (311) reflection. Coatings obtained at high current densities and duty cycles present a mixed morphology of small and large grains. Maximum microhardness of 193 Hv was achieved at 4 A/dm2, 10 Hz and duty cycle of 50%. Nickel coatings with (200) texture are ductile while (111) texture improves the microhardness of the coatings.

Keywords: current density, duty cycle, microstructure, nickel, pulse frequency

Procedia PDF Downloads 366
2521 Toxicity of Biopesticide Metarhizium anisopliae var acridium "Green Muscle" on the Cuticle of the Desert Locust Schistocerca gegaria (Forskål, 1775)

Authors: F. Haddadj, F. Acheuk, S. Hamdi, S. Zenia, A. Smai, H. Saadi, B. Doumandji-Mitiche

Abstract:

Locust is causing significant losses in agricultural production in the countries concerned by the invasion. Up to the present control strategy has consisted only of the spreaders chemicals; they have proven harmful to the environment and. For this, a new control method appeared it comes to the biological control based mostly by using microorganism. It is in that sense is we've made our contribution by the use of a biopesticide which is entomopathogenic fungus Metarhizium anisopliae var acridium "Green Muscle" on part of the cuticule the larval of fifth instar locust Schistocerca gregaria (Forskål, 1775). Preliminary test on the study of the pathogenicity of M. anisopliae var acridium biocontrol agent, was conducted in the laboratory on L5 S. gregaria, on which we inoculated treatment in the digestive tract and it administrant 20μl of entomopathogenic solution orally at a dose DL50 = 3.25 x107 sp./ ml (median lethal dose estimated at earlier), 5 days after treatment individuals are sacrificed. After dissection cuticles are recovered and then subjected to histological sections. The histological technique followed is that of Martoja Martoja-Pierson (1967). Microscopic observation revealed alterations in the architecture of the cuticule which leads to disorganization of cell layers.

Keywords: biopesticide, cuticle, desert locust, toxicity

Procedia PDF Downloads 477
2520 In vivo Evidence of Protective Effect of Hyparrhenia Hirta against Nitrate-Induced Genotoxicity

Authors: H. Bouaziz-Ketata, G. Ben Salah, Z. Aidi, C. Kallel, H. Kammoun, F. Fakhfakh, N. Zeghal

Abstract:

The present study was performed to evaluate the potential protective effect of Hyparrhenia hirta methanolic extract in NaNO3-induced genotoxic and hematotoxic effects. Male Wistar rats were randomly divided into three groups: a control group and two treated groups during 50 days with NaNO3 administered at a dose of 400 mg kg-1 bw either alone in drinking water or co-administered with Hyparrhenia hirta at a dose of 200 mg kg-1 bw. NaNO3 treatment showed a significant increase in the frequencies of total chromosomal aberrations, aberrant metaphases and micronucleus in bone-marrow cells. In parallel, the NaNO3-treated group showed a significant decrease in red blood cell count, hemoglobin and hematocrit and a significant increase in total white blood cell, in neutrophil and eosinophil counts. Platelet count, mean corpuscular volume, mean corpuscular hemoglobin, and mean corpuscular hemoglobin concentration remained unchanged in treated groups compared to those of controls. Hyparrhenia hirta methanolic extract appeared to be effective against genotoxic and hematotoxic changes induced by nitrate, as evidenced by the improvement of the markers cited above.

Keywords: Hyparrhenia hirta, sodium nitrate, erythrocytes, genotoxicity

Procedia PDF Downloads 255
2519 The Effect of Pregabalin on Postoperative Pain after Anterior Cruciate Ligament Reconstruction: A Systematic Review of Randomized Clinical Trials

Authors: Emad Kouhestani

Abstract:

Background: Despite the enormous success of anterior cruciate ligament (ACL) reconstruction, acute neuropathic pain can develop postoperatively and is both distressing and difficult to treat once established. Pregabalin, as an anticonvulsant agent that selectively affects the nociceptive process, has been used as a pain relief agent. The purpose of this systematic review of randomized controlled trials (RCTs) was to evaluate the pain control effect of pregabalin versus placebo after ACL reconstruction. Method: A search of the literature was performed from inception to June 2022, using PubMed, Scopus, Google Scholar, Web of Science, Cochrane, and EBSCO. Studies considered for inclusion were RCTs that reported relevant outcomes (postoperative pain scores, or cumulative opioid consumption, adverse events) following the administration of pregabalin in patients undergoing ACL reconstruction. Result: Five placebo-controlled RCTs involving 272 participants met the inclusion criteria. 75 mg and 150 mg of oral pregabalin were used in included trials. Two studies used a single dose of pregabalin one hour before anesthesia induction. Two studies used pregabalin 1 hour before anesthesia induction and 12 hours after. One study used daily pregabalin 7 days before and 7 days after surgery. Out of five papers, three papers found significantly lower pain intensity and cumulative opioid consumption in the pregabalin group compared with the placebo group. However, a decrease in pain scores was found in all trials. Pregabalin administration was associated with dizziness and nausea. Conclusion: The use of pregabalin may be a valuable asset in pain management after ACL reconstruction. However, future studies with larger sample sizes and longer follow-up periods are required.

Keywords: pregabalin, anterior cruciate ligament, postoperative pain, clinical trial

Procedia PDF Downloads 84
2518 The Effect of Vitamin D Supplements and Aerobic Exercise on Hunger and Serum Insulin Levels in Adolescents With Metabolic Syndrome

Authors: Vahab Behmanesh

Abstract:

Metabolic syndrome is defined as having at least three of the five metabolic risk factors, including abdominal obesity, high blood pressure, high triglycerides, low HDL, and insulin resistance. Lifestyle changes towards reducing physical activity, unhealthy eating habits Especially the high-fat and high-carbohydrate diet is directly related to metabolic syndrome, and due to the epidemic of overweight and sedentary life, metabolic syndrome is a serious problem worldwide. On the other hand, vitamin D deficiency is considered as one of the most common problems in the world, which is related to the dysfunction of beta cells and insulin resistance, and therefore, vitamin D deficiency is considered as a factor in the occurrence of metabolic syndrome. 40 subjects (age: 16.12 ± 4.4 years and body mass index 25.61 ± 4.4 kg/m2) were randomly assigned to groups of aerobic exercise and placebo, aerobic exercise and vitamin D and placebo (no exercise) were divided. Vitamin D was taken at a dose of 50,000 units per week in a double-blind format for eight weeks, and the daily aerobic exercise program was performed for 50 to 60 minutes, three doses per week, with an intensity of 50-60% of the maximum heart rate. From one-way analysis of variance, Factorial variance analysis (2x2) repeated measurement and correlated t-test were used for data analysis. Aerobic exercise and vitamin D intake reduced all metabolic risk indicators and blood insulin (P < 0.05). However, the subjective feeling of hunger did not change significantly (P < 0.05). Regarding waist circumference and blood glucose, the effect of exercise combined with vitamin D consumption was greater than the corresponding effect in the vitamin D group (P < 0.05). Aerobic exercises and vitamin D intake are safe and effective for improving cardiometabolic health, Imam adds vitamin D to the exercise program has more benefits for weight and blood sugar control, which suggests prescribing it for patients with metabolic syndrome.

Keywords: vitamin D, aerobic exercise, metabolic control, adolescents

Procedia PDF Downloads 99
2517 Experimental Lead Toxicity in Lohi Sheep: Risks and Impact on Edible Tissues

Authors: Muhammad Younus, Muhammad Sajid, Muti-ur-Rehman Khan, Aftab Ahmad Anjum, Muhammad Asif Idrees, Iahtasham Khan, Aman Ullah Khan, Sajid Umar, Raheela Akhtar

Abstract:

The present study was conducted to investigate the hazardous effects of lead on health and edible organs of Lohi sheep. The adult Lohi sheep (n=48) were randomly divided into two equal groups. The first group was administered lead acetate at dose of 70 mg/kg live body weight daily as 10% solution by oral route for a period of 90 days and the second group served as a negative control. Blood and tissue samples were collected at day 0, 30, 60 and 90 and analyzed for lead concentration by atomic absorption spectrophotometry. The kidney showed the highest lead concentration (p < 0.05) followed by liver and then muscle. Lead acetate treated sheep showed structural and behavioral changes during the last month of trial. Liver showed necrosis, hemorrhages and hyperactivation of macrophages. Kidney showed degenerative and necrotic changes in glomeruli and tubules and the characteristic intranuclear inclusion bodies in tubular epithelial cells on H and E staining. It was concluded that Lohi sheep is affected by lead intoxication at low dose for longer period and hence exhibits lead accumulation in edible tissues.

Keywords: Lohi sheep, lead acetate, edible tissue, histopathology

Procedia PDF Downloads 451
2516 Ameliorating Effects of Rosemary and Costus on Blood-Associated Toxicity in Ehrlich-Bearing Mice Treated with Cisplatin

Authors: Yousry El-Sayed Elbolkiny, Mohamed Labib Salem

Abstract:

Background: Rosemary (ROLE) and costus (SLRE) have been established to show antioxidant effects. Aim: This study aimed to evaluate the ameliorating effects of ROLE and SLRE on the side effects induced by cisplatin (CIS) in tumor-bearing mice. Materials and Methods: Extracts of ROLE and SLRE were examined for their phytochemical activities. To evaluate their anti-tumor effects, mice were inoculated intraperitoneally (i.p.) with 2.5x105 Ehrlich ascites carcinoma (EAC) and then treated i.p. with CIS at days 3-7 and with ROLE (dose) or SLRE (dose) at days 3-14. Mice were sacrificed on day 14 for CBC and T-cell analyses. Results: Phytochemical analysis revealed that both ROLE and SLRE showed similar antioxidant activities. Treatment of EAC-bearing mice with CIS-induced antitumor efficacy of about 90%. Treatment with CIS in combination with ROLE or SLRE did not further enhance the antitumor activity of CIS. However, co-administration of ROLE or SLRE with CIS significantly increased the antitumor efficacy of CIS. Flow cytometric analysis showed that the numbers of CD4+ and CD8+ T cells were decreased in EAC-bearing mice after treatment with CIS. Treatment with both ROLE and SLRE improved the number of these cells. Conclusion: Combinatorial treatment with rosemary and costus can enhance the antitumor activity of CIS

Keywords: CBC, cisplantin, costus, rosemary

Procedia PDF Downloads 41
2515 Photocatalytic Degradation of Gaseous Toluene: Effects of Operational Variables on Efficiency Rate of TiO2 Coated on Nickel Foam

Authors: Jafar Akbari, Masoud Rismanchian, Samira Ramezani

Abstract:

Purpose: The photocatalytic degradation of pollutants is a novel technology with various advantages such as high efficiency and energy saving. In this research, the effects of operational variables on the photocatalytic efficiency of TiO₂ coated on nickel foam in the removal of toluene from the simulated indoor air have been investigated. Methods: TiO₂ film were prepared via the sol-gel method and coated on nickel foam. The characteristics and morphology were found using XRD, SEM, and BET technique. Then, the effects of relative humidity, UV-A intensity, the initial toluene concentration, TiO₂ loading, and the air circulation velocity on the photocatalytic degradation rate have been evaluated. Results: The optimal degradation of toluene has been achieved with loading 4.35 g TiO2 on the foam, 30% RH, 5.4 µW.cm−2 UV-A intensity, and 20 ppm initial concentration in the air circulation velocity of 0.15 fpm. Conclusion: The changes of toluene photocatalytic degradation rate have been studied at various times. Also, the kinetic behavior of toluene photocatalytic degradation has been investigated using Langmuir-Hinshelwood (L-H) model.

Keywords: photocatalytic degradation, operational variables, tio₂, nickel foam, gaseous toluene, nanotechnology

Procedia PDF Downloads 78
2514 Comparative Study Between Two Different Techniques for Postoperative Analgesia in Cesarean Section Delivery

Authors: Nermeen Elbeltagy, Sara Hassan, Tamer Hosny, Mostafa Abdelaziz

Abstract:

Introduction: Adequate postoperative analgesia after caesarean section (CS) is crucial as it impacts the distinct surgical recovery needs of the parturient. Over recent years, there has been increased interest in regional nerve block techniques with promising results on efficacy. These techniques reduce the need for additional analgesia, thereby lowering the incidence of drug-related side effects. As postoperative pain after cesarean is mainly due to abdominal incision, the transverses abdomenis plane ( TAP ) block is a relatively new abdominal nerve block with excellent efficacy after different abdominal surgeries, including cesarean section. Objective: The main objective is to compare ultrasound-guided TAP block provided by the anesthesiologist with TAP provided by the surgeon through a caesarean incision regarding the duration of postoperative analgesia, intensity of analgesia, timing of mobilization, and easiness of the procedure. Method: Ninety pregnant females at term who were scheduled for delivery by elective cesarean section were randomly distributed into two groups. The first group (45) received spinal anesthesia and postoperative ultrasound guided TAP block using 20ml on each side of 0.25% bupivacaine which was provided by the anesthesiologist. The second group (45) received spinal anesthesia plus a TAP block using 20ml on each side of 0.25% bupivacaine, which was provided by the surgeon through the cesarean incision. Visual Analogue Scale (VAS) was used for the comparison between the two groups. Results: VAS score after four hours was higher among the TAP block group provided by the surgeon through the surgical incision than the postoperative analgesic profile using ultrasound-guided TAP block provided by the anesthesiologist (P=0.011). On the contrary, there was no statistical difference in the patient’s dose of analgesia after four hours of the TAP block (P=0.228). Conclusion: TAP block provided through the surgical incision is safe and enhances early patient’s mobilization.

Keywords: TAP block, CS, VAS, analgesia

Procedia PDF Downloads 44
2513 Evaluation of IMERG Performance at Estimating the Rainfall Properties through Convective and Stratiform Rain Events in a Semi-Arid Region of Mexico

Authors: Eric Muñoz de la Torre, Julián González Trinidad, Efrén González Ramírez

Abstract:

Rain varies greatly in its duration, intensity, and spatial coverage, it is important to have sub-daily rainfall data for various applications, including risk prevention. However, the ground measurements are limited by the low and irregular density of rain gauges. An alternative to this problem are the Satellite Precipitation Products (SPPs) that use passive microwave and infrared sensors to estimate rainfall, as IMERG, however, these SPPs have to be validated before their application. The aim of this study is to evaluate the performance of the IMERG: Integrated Multi-satellitE Retrievals for Global Precipitation Measurament final run V06B SPP in a semi-arid region of Mexico, using 4 automatic rain gauges (pluviographs) sub-daily data of October 2019 and June to September 2021, using the Minimum inter-event Time (MIT) criterion to separate unique rain events with a dry period of 10 hrs. for the purpose of evaluating the rainfall properties (depth, duration and intensity). Point to pixel analysis, continuous, categorical, and volumetric statistical metrics were used. Results show that IMERG is capable to estimate the rainfall depth with a slight overestimation but is unable to identify the real duration and intensity of the rain events, showing large overestimations and underestimations, respectively. The study zone presented 80 to 85 % of convective rain events, the rest were stratiform rain events, classified by the depth magnitude variation of IMERG pixels and pluviographs. IMERG showed poorer performance at detecting the first ones but had a good performance at estimating stratiform rain events that are originated by Cold Fronts.

Keywords: IMERG, rainfall, rain gauge, remote sensing, statistical evaluation

Procedia PDF Downloads 64
2512 Effect Of Tephrosia purpurea (Family: Fabaceae) Formulations On Oviposition By The Pulse Beetle Callosobruchus chinensis Linn.

Authors: Priyanka Jain, Meera Srivastava

Abstract:

Among important insect pests of stored grains, the pulse beetle Callosobruchus chinensis Linn. (Coleoptera: Bruchidae) is one such pest causing considerable damage to stored pulses. An effort was made to screen plant Tephrosia purpurea (Family: Fabaceae) for its efficacy against the said pest. The pulse beetle C. chinensis was raised on green gram Vigna radiata in incubators maintained at 28 ± 2°C and 70% RH. Different formulations using plant parts (root, stem, leaf and fruit) were employed in the form of aqueous suspension, aqueous extract and ether extract and the treatments were made using different dose concentrations, namely 1%, 2.5%, 5% and 10%, besides normal and control. Specific number of adult insects were released in muslin cloth covered beakers containing weighed green gram grains and treated with different dose concentrations (w/v). Observations for the number of eggs laid by the pest insect C. chinensis was recorded after three days of treatment and it was observed that in general all the treatments of the plant resulted in significant decrease in the eggs laid (no/pair) by the insect, suggesting that the selected plant has a potential to be used against C. chinensis.

Keywords: Callosobruchus chinensis, egg laying, Tephrosia purpurea, Fabaceae, plant formulations

Procedia PDF Downloads 339
2511 Computer Assisted Strategies Help to Pharmacist

Authors: Komal Fizza

Abstract:

All around the world in every field professionals are taking great support from their computers. Computer assisted strategies not only increase the efficiency of the professionals but also in case of healthcare they help in life-saving interventions. The background of this current research is aimed towards two things; first to find out if computer assisted strategies are useful for Pharmacist for not and secondly how much these assist a Pharmacist to do quality interventions. Shifa International Hospital is a 500 bedded hospital, and it is running Antimicrobial Stewardship, during their stewardship rounds pharmacists observed that a lot of wrong doses of antibiotics were coming at times those were being overlooked by the other pharmacist even. So, with the help of MIS team the patients were categorized into adult and peads depending upon their age. Minimum and maximum dose of every single antibiotic present in the pharmacy that could be dispensed to the patient was developed. These were linked to the order entry window. So whenever pharmacist would type any order and the dose would be below or above the therapeutic limit this would give an alert to the pharmacist. Whenever this message pop-up this was recorded at the back end along with the antibiotic name, pharmacist ID, date, and time. From 14th of January 2015 and till 14th of March 2015 the software stopped different users 350 times. Out of this 300 were found to be major errors which if reached to the patient could have harmed them to the greater extent. While 50 were due to typing errors and minor deviations. The pilot study showed that computer assisted strategies can be of great help to the pharmacist. They can improve the efficacy and quality of interventions.

Keywords: antibiotics, computer assisted strategies, pharmacist, stewardship

Procedia PDF Downloads 485
2510 Effect of High Dose of Black Tea Extract on Physiological Parameters of Mother and Pups in Experimental Albino Rats

Authors: Avijit Dey, Antony Gomes, Subir Chandra Dasgupta

Abstract:

Tea (Camellia sinensis) is the most popular beverages in the world and is ranked second after the water. Tea has been considered as a health promoting beverage since ancient times due to its health-promoting activity. Recently, immunomodulatory, anti-arthritic, antioxidant, anticancer and cardioprotective activity of tea has been established. Very few studies have demonstrated the effect of high dose of black tea on health. The aim of the present study was to evaluate the role of low & high dose of Black Tea Extract (BTE) on the different physiological parameters of mother and pups during prenatal and postnatal developmental period in the experimental rodent. BTE was orally administered in LD (50mg BTE/kg/day) and HD (100mg BTE/kg/day) except control groups of rats (n=6/group) throughout the prenatal (day 0-21) and postnatal (day 21-42) periods. During prenatal period (0, 7th, 14th, 20th days) body weight, urinary calcium, magnesium, urea and creatinine was measured. In postnatal period physical (0, 10th, 21th days) parameters of pups like body weight, cranial length, cranial diameter, neck width, tail length, craniosacral length of pups were analyzed. Liver and lungs from pups and kidney spleen, etc. from mothers were collected on day 42 for histopathological studies. The comparative urine strip and morphology of RBC was also analyzed by SEM from mothers of different groups on day 42. The level of cytokines like IL-1alpha, IL-1beta, IL-6, IL-10, TNF-alpha were analysed by enzyme-linked immunosorbent assay (ELISA) on day 0, day 20 and day 42. The body weight of LD and HD mothers were also significantly (P<0.05) less than control mothers at 20th day of pregnancy and there was also significant changes in urinary calcium, urea, creatinine. The bio morphometric analysis of pups showed significant alteration (P<0.05) in HD groups relative to control. Some histological alterations were also observed in pups and mothers. Comparative urine strip analysis and morphology of RBC showed significant changes in treated groups. LD and HD treated mothers showed an increase in proinflammatory cytokines like IL-1beta, TNF-alpha and decrease in anti-inflammatory cytokine-like IL-10 on day 20 compared to PC mothers. This study clearly indicated that high dose of BTE possesses detrimental effect on pregnant mother and the pup. Further studies are in progress to elucidate the molecular mechanism of actions. This project work has been sponsored by National Tea Research Foundation vide Project Sanction No.: 17 (305)/2013/4423 dated 11th March, 2014. All experimental protocols described in the study were approved by animal ethics committee.

Keywords: black tea extract, pregnancy, prenatal and postnatal development, inflammation

Procedia PDF Downloads 268
2509 Purification of Bilge Water by Adsorption

Authors: Fatiha Atmani, Lamia Djellab, Nacera Yeddou Mezenner, Zohra Bensaadi

Abstract:

Generally, bilge waters can be briefly defined as saline and greasy wastewaters. The oil and grease are mixed with the sea water, which affects many marine species. Bilge water is a complex mixture of various compounds such as solvents, surfactants, fuel, lubricating oils, and hydraulic oils. It is resulted mainly by the leakage from the machinery and fresh water washdowns,which are allowed to drain to the lowest inner part of the ship's hull. There are several physicochemical methods used for bilge water treatment such as biodegradation electrochemical and electro-coagulation/flotation.The research herein presented discusses adsorption as a method to treat bilge water and eggshells were studied as an adsorbent. The influence of operating parameters as contact time, temperature and adsorbent dose (0,2 - 2g/l) on the removal efficiency of Chemical oxygen demand, COD, and turbidity was analyzed. The bilge wastewater used for this study was supplied by Harbour Bouharoune. Chemical oxygen demand removal increased from 26.7% to 68.7% as the adsorbent dose increased from 0.2 to 2 g. The kinetics of adsorption by eggshells were fast, reaching 55 % of the total adsorption capacity in ten minutes (T= 20°C, pH =7.66, m=2g/L). It was found that the turbidity removal efficiency decreased and 95% were achieved at the end of 90 min reaction. The adsorption process was found to be effective for the purification of bilge water and pseudo-second-order kinetic model was fitted for COD removal.

Keywords: adsorption, bilge water, eggshells and kinetics, equilibrium and kinetics

Procedia PDF Downloads 352
2508 A Prospective Audit to Look into Antimicrobial Prescribing in the Clinical Setting: In a Teaching Hospital in the UK

Authors: Richa Sinha, Mohammad Irfan Javed, Sanjay Singh

Abstract:

Introduction: Good antimicrobial prescribing reduces length of stay in hospital, risk of adverse events, antimicrobial resistance, and unnecessary hospital expenditure. The aim of this prospective audit was to identify any problems with antimicrobial prescribing including documentation of the relevant aspects as well as appropriateness of antibiotics use. The audit was conducted on the surgical wards in a teaching hospital in the UK. Methods: Standards included the indication, duration, choice, and prescription of antibiotic should be in line with current Regional Guidelines and should be clearly documented on the prescription chart. There should be an entry in each patients’ medical record of the diagnosis and indication for each acute antibiotic prescription issued. All prescriptions should clearly document the route, frequency and dose of antibiotic. Data collection was done for 2 weeks in the month of March 2014. A proforma including all the questions above was completed for all the patients. The results were analysed using Excel. Results: 35 patients in total were selected for the audit. 85.7% of patients had indication of antibiotic documented on the prescription chart and 68.5% of patients had indication documented in the notes. The antibiotic used was in line with hospital guidelines in 45.7% of patients, however, in a further 28.5% of patients the reason for the antibiotic prescription was microbiology approved. Therefore, in total 74.2% of patients had been prescribed appropriate antibiotics. The duration of antibiotic was documented in 68.6% of patients and the antibiotic was reviewed in 37.1% of patients. The dose, frequency and route was documented clearly in 100% of patients. Conclusion: Overall, prescribing can be improved on the surgical wards in this hospital. Only 37.1% of patients had clear documentation of a review of antibiotics. It may be that antibiotics have been reviewed but this should be clearly highlighted on the prescription chart or the notes. Failure to review antibiotics can lead to poor patient care and antimicrobial resistance and therefore it is important to address this. It is also important to address the appropriateness of antibiotics as inappropriate antibiotic prescription can lead to failure of treatment as well as antimicrobial resistance. The good points from the audit was that all patients had clear documentation of dose, route and frequency which is extremely important in the administration of antibiotics. Recommendations from this audit included to emphasize good antimicrobial prescribing at induction (twice yearly), an antimicrobial handbook for junior doctors, and re-audit in 6 months time.

Keywords: prescribing, antimicrobial, indication, duration

Procedia PDF Downloads 296
2507 Considerations for the Use of High Intensity Interval Training in Secondary Physical Education

Authors: Amy Stringer, Resa Chandler

Abstract:

High Intensity Interval Training (HIIT) involves a 3-10-minute circuit of various exercises which is a viable alternative to a traditional cardiovascular and strength training regimen. Research suggests that measures of health-related fitness can either be maintained or actually improve with the use of this training method. After conducting a 6-week HIIT research study with 10-14 year old children, considerations for using a daily HIIT workout are presented. Is the use of HIIT with children a reasonable consideration for physical education programs? The benefits and challenges of this type of an intervention are identified. This study is significant in that achieving fitness gains in a small amount of daily class time is an attractive concept – especially for physical education teachers who often do not have the time necessary to accomplish all of their curricular goals in the amount of class time assigned. Basic methodologies include students participating in a circuit of exercises for 7-10 minutes at 80-95% of max heart rate as measured by heart rate monitors. Student pre and post fitness test data were collected for cardio-vascular endurance, muscular endurance, and body composition. Research notes as well as commentary by the teachers and researchers who participated in the HIIT study contributed to the understanding of the cost-benefit analysis. Major findings of the study are that HIIT has limited effectiveness but is a good choice for limited class times. Student efficacy of their ability to complete the exercises and visible heart rate data were considered to be significant factors in success of the HIIT study. The effective use of technology promoting positive audience effect during the display of heart rate data was more important at the beginning of the study than at the end. Student ‘buy-in’ and motivation, teacher motivation and ‘buy-in’, the variety of activities in the circuit and the fitness level of the student at the beginning of the study were also findings influencing the fitness outcomes of the study. Concluding Statement: High intensity interval training can be used effectively in a secondary physical education program. It is not a ‘magic bullet’ to produce health-related fitness outcomes in every student but it is an effective tool to enhance student fitness in a limited time and contribute to the goals of the program.

Keywords: cardio vascular fitness, children, high intensity interval training, physical education

Procedia PDF Downloads 112
2506 Genetic Determinants of Ovarian Response to Gonadotropin Stimulation in Women Undergoing Assisted Reproductive Treatment

Authors: D. Tohlob, E. Abo Hashem, N. Ghareeb, M. Ghanem, R. Elfarahaty, S. A. Roberts, P. Pemberton, L. Mohiyiddeen, W. G. Newman

Abstract:

Gonadotropin stimulation is used in females undergoing assisted reproductive treatment for ovulation induction, but ovarian response is variable and unpredictable in these women. More effective protocols and individualization of treatment are needed to increase the success rate of IVF/ICSI cycles. We genotyped seven variants reported in previous studies to be associated with ovarian response (number of ova retrieved and total gonadotropin dose) in women undergoing IVF treatment including FSHR variants Asn 680 Ser (c.2039 A > G), Thr 307 Ala (c. 919 > A), -29 G > A, HRG c.610 C > T gene, BMP15 -9 C > G, AMH Ile 49 Ser (c.146 G > T), and AMHR -489A˃G in 118 Egyptian females attending Mansoura Integrated Fertility Center in Egypt, these females were undergoing their first cycle of controlled ovarian hyper stimulation for IVF/ICSI treatment. They were analyzed by TaqMan allelic discrimination assay in Manchester Center of Genomic Medicine. We found no evidence of any significant difference (p value < 0.05) in the number of eggs retrieved or the gonadotropin dose used between individuals in all genotypes except for HRG c.610 C > T gene polymorphism where regression analysis gives a p value of 0.04 with a fewer eggs number in TT genotyped females. These results indicate that these variants do not provide sufficient clinically relevant data to individualize the treatment protocols.

Keywords: controlled ovarian hyperstimulation, gene variants, ovarian response, assisted reproduction

Procedia PDF Downloads 313
2505 Impact of an Eight-Week High-Intensity Interval Training with Sodium Nitrite Supplementation on TNF-α, MURF1, and PI3K in Type 2 Diabetic Rats

Authors: Samane Eftekhari Ranjbar

Abstract:

Diabetes mellitus, a metabolic disorder characterized by elevated blood glucose levels, ranks among the leading causes of adult mortality. This study investigates the impact of an eight-week high-intensity interval training (HIIT) program combined with sodium nitrite supplementation on TNF- α, MURF1, and PI3K in a type 2 diabetes rodent model. Elevated TNF-α levels have been associated with insulin resistance, while MURF1 and PI3K play roles in muscle atrophy and insulin signaling pathways, respectively. In this experimental study, 15 eight-week-old rats from the Sara Laboratory Center in Tabriz were assigned to one of five groups: healthy control, diabetic control, diabetic with sodium nitrite supplementation, diabetic with eight weeks of intermittent exercise, and diabetic with eight weeks of interval training plus sodium nitrite supplementation. The HIIT protocol was designed to span eight weeks, with five weekly sessions at specified intensities and durations. Sodium nitrite, known for its vasodilatory and cytoprotective properties, was administered via injection. The findings revealed that the HIIT program and sodium nitrite supplementation influenced the examined biomarkers. ANOVA test outcomes indicated statistically significant differences in TNF- α (P=0.001), MURF1 (P=0.001), and PI3K (P=0.001) concentrations among the various groups. The healthy control group exhibited substantially decreased TNF- α, and MURF1 levels, as well as elevated PI3K levels compared to the diabetic control group. The exercise group, in conjunction with sodium nitrite supplementation, demonstrated a significant rise in PI3K levels (P=0.001) and a decline in TNF- α levels (P=0.018) relative to the diabetic control group. These results suggest that the combined intervention may help improve insulin sensitivity and reduce inflammation. However, MURF1 levels, which are related to muscle atrophy, showed no significant difference (P=0.24). In conclusion, in type 2 diabetic rats, an eight-week high-intensity interval training program with sodium nitrite supplementation does not affect MURF1 levels but does influence PI3K and TNF- α levels. This combination may hold potential for improving insulin sensitivity and reducing inflammation in type 2 diabetes patients, warranting further investigation and potential translation to human clinical trials.

Keywords: high-intensity interval training, sodium nitrate supplementation, type 2 diabetes, tumor necrosis factor-alpha, phosphatidylinositol-3-kinase, muscle RING-finger protein-1

Procedia PDF Downloads 79
2504 X-Ray Detector Technology Optimization In CT Imaging

Authors: Aziz Ikhlef

Abstract:

Most of multi-slices CT scanners are built with detectors composed of scintillator - photodiodes arrays. The photodiodes arrays are mainly based on front-illuminated technology for detectors under 64 slices and on back-illuminated photodiode for systems of 64 slices or more. The designs based on back-illuminated photodiodes were being investigated for CT machines to overcome the challenge of the higher number of runs and connection required in front-illuminated diodes. In backlit diodes, the electronic noise has already been improved because of the reduction of the load capacitance due to the routing reduction. This translated by a better image quality in low signal application, improving low dose imaging in large patient population. With the fast development of multi-detector-rows CT (MDCT) scanners and the increasing number of examinations, the clinical community has raised significant concerns on radiation dose received by the patient in both medical and regulatory community. In order to reduce individual exposure and in response to the recommendations of the International Commission on Radiological Protection (ICRP) which suggests that all exposures should be kept as low as reasonably achievable (ALARA), every manufacturer is trying to implement strategies and solutions to optimize dose efficiency and image quality based on x-ray emission and scanning parameters. The added demands on the CT detector performance also comes from the increased utilization of spectral CT or dual-energy CT in which projection data of two different tube potentials are collected. One of the approaches utilizes a technology called fast-kVp switching in which the tube voltage is switched between 80kVp and 140kVp in fraction of a millisecond. To reduce the cross-contamination of signals, the scintillator based detector temporal response has to be extremely fast to minimize the residual signal from previous samples. In addition, this paper will present an overview of detector technologies and image chain improvement which have been investigated in the last few years to improve the signal-noise ratio and the dose efficiency CT scanners in regular examinations and in energy discrimination techniques. Several parameters of the image chain in general and in the detector technology contribute in the optimization of the final image quality. We will go through the properties of the post-patient collimation to improve the scatter-to-primary ratio, the scintillator material properties such as light output, afterglow, primary speed, crosstalk to improve the spectral imaging, the photodiode design characteristics and the data acquisition system (DAS) to optimize for crosstalk, noise and temporal/spatial resolution.

Keywords: computed tomography, X-ray detector, medical imaging, image quality, artifacts

Procedia PDF Downloads 261
2503 Influence of an External Magnetic Field on the Acoustomagnetoelectric Field in a Rectangular Quantum Wire with an Infinite Potential by Using a Quantum Kinetic Equation

Authors: N. Q. Bau, N. V. Nghia

Abstract:

The acoustomagnetoelectric (AME) field in a rectangular quantum wire with an infinite potential (RQWIP) is calculated in the presence of an external magnetic field (EMF) by using the quantum kinetic equation for the distribution function of electrons system interacting with external phonons and electrons scattering with internal acoustic phonon in a RQWIP. We obtained ananalytic expression for the AME field in the RQWIP in the presence of the EMF. The dependence of AME field on the frequency of external acoustic wave, the temperature T of system, the cyclotron frequency of the EMF and the intensity of the EMF is obtained. Theoretical results for the AME field are numerically evaluated, plotted and discussed for a specific RQWIP GaAs/GaAsAl. This result has shown that the dependence of the AME field on intensity of the EMF is nonlinearly and it is many distinct maxima in the quantized magnetic region. We also compared received fields with those for normal bulk semiconductors, quantum well and quantum wire to show the difference. The influence of an EMF on AME field in a RQWIP is newly developed.

Keywords: rectangular quantum wire, acoustomagnetoelectric field, electron-phonon interaction, kinetic equation method

Procedia PDF Downloads 327
2502 Enhancement of X-Rays Images Intensity Using Pixel Values Adjustments Technique

Authors: Yousif Mohamed Y. Abdallah, Razan Manofely, Rajab M. Ben Yousef

Abstract:

X-Ray images are very popular as a first tool for diagnosis. Automating the process of analysis of such images is important in order to help physician procedures. In this practice, teeth segmentation from the radiographic images and feature extraction are essential steps. The main objective of this study was to study correction preprocessing of x-rays images using local adaptive filters in order to evaluate contrast enhancement pattern in different x-rays images such as grey color and to evaluate the usage of new nonlinear approach for contrast enhancement of soft tissues in x-rays images. The data analyzed by using MatLab program to enhance the contrast within the soft tissues, the gray levels in both enhanced and unenhanced images and noise variance. The main techniques of enhancement used in this study were contrast enhancement filtering and deblurring images using the blind deconvolution algorithm. In this paper, prominent constraints are firstly preservation of image's overall look; secondly, preservation of the diagnostic content in the image and thirdly detection of small low contrast details in diagnostic content of the image.

Keywords: enhancement, x-rays, pixel intensity values, MatLab

Procedia PDF Downloads 476
2501 Self-Selected Intensity and Discounting Rates of Exercise in Comparison with Food and Money in Healthy Adults

Authors: Tamam Albelwi, Robert Rogers, Hans-Peter Kubis

Abstract:

Background: Exercise is widely acknowledged as a highly important health behavior, which reduces risks related to lifestyle diseases like type 2 diabetes, cardiovascular disease. However, exercise adherence is low in high-risk groups and sedentary lifestyle is more the norm than the exception. Expressed reasons for exercise participation are often based on delayed outcomes related to health threats and benefits but also enjoyment. Whether exercise is perceived as rewarding is well established in animal literature but the evidence is sparse in humans. Additionally, the question how stable any reward is perceived with time delays is an important question influencing decision-making (in favor or against a behavior). For the modality exercise, this has not been examined before. We, therefore, investigated the discounting of pre-established self-selected exercise compared with established rewards of food and money with a computer-based discounting paradigm. We hypothesized that exercise will be discounted like an established reward (food and money); however, we expect that the discounting rate is similar to a consumable reward like food. Additionally, we expected that individuals’ characteristics like preferred intensity, physical activity and body characteristics are associated with discount rates. Methods: 71 participants took part in four sessions. The sessions were designed to let participants select their preferred exercise intensity on a treadmill. Participants were asked to adjust their speed for optimizing pleasantness over an exercise period of up to 30 minutes, heart rate and pleasantness rating was measured. In further sessions, the established exercise intensity was modified and tested on perceptual validity. In the last exercise session rates of perceived exertion was measured on the preferred intensity level. Furthermore, participants filled in questionnaires related to physical activity, mood, craving, and impulsivity and answered choice questions on a bespoke computer task to establish discounting rates of their preferred exercise (kex), their favorite food (kfood) and a value-matching amount of money (kmoney). Results: Participants self-selected preferred speed was 5.5±2.24 km/h, at a heart rate of 120.7±23.5, and perceived exertion scale of 10.13±2.06. This shows that participants preferred a light exercise intensity with low to moderate cardiovascular strain based on perceived pleasantness. Computer assessment of discounting rates revealed that exercise was quickly discounted like a consumable reward, no significant difference between kfood and kex (kfood =0.322±0.263; kex=0.223±0.203). However, kmoney (kmoney=0.080±0.02) was significantly lower than the rates of exercise and food. Moreover, significant associations were found between preferred speed and kex (r=-0.302) and between physical activity levels and preferred speed (r=0.324). Outcomes show that participants perceived and discounted self-selected exercise like an established reward (food and money) but was discounted more like consumable rewards. Moreover, exercise discounting was quicker in individuals who preferred lower speeds, being less physically active. This may show that in a choice conflict between exercise and food the delay of exercise (because of distance) might disadvantage exercise as the chosen behavior particular in sedentary people. Conclusion: exercise can be perceived as a reward and is discounted quickly in time like food. Pleasant exercise experience is connected to low to moderate cardiovascular and perceptual strain.

Keywords: delay discounting, exercise, temporal discounting, time perspective

Procedia PDF Downloads 268
2500 3D Virtualization through Data Collected from Measurements of Mobile Signal Reception Power Levels (LTE) Band at Escuela Superior Politécnica de Chimborazo in Riobamba-Ecuador

Authors: Sandra Cuenca, Steven Chango, Fabian Chamba, Alexandra Vaca

Abstract:

This project addresses a representation of a virtual environment based on the analysis of the RSRP (Reference Signal Received Power) obtained by the Network Cell Info Lite application at the Escuela Superior Politécnica de Chimborazo (ESPOCH) considering the open areas of the Business Administration Department in the 4G LTE Frequency (band 2) of Claro Telephony at a frequency of 1967. 5 MHz, where measurements were performed from 17:00 UTC-05:00. The indicators required for the simulation of the environment designed in sketchup were focused especially on the power levels obtained where it was possible to represent the scenario with real power values obtained in each concentric radius of a total of 3 campaigns of 200 samples each, where the values vary between 84.6 dBm to 115.5 dBm having average power values for each of the 23 radiuses which are introduced in a virtual environment, allowing users to immerse themselves in it, where they can explore 3D virtual environments, generating a color scale from 0 to 10 with red being the weakest signal and green the signal with the best intensity.

Keywords: virtualization, LTE, radios, power intensity levels colors, mobile signal reception power

Procedia PDF Downloads 82
2499 An Experimental Investigation of the Surface Pressure on Flat Plates in Turbulent Boundary Layers

Authors: Azadeh Jafari, Farzin Ghanadi, Matthew J. Emes, Maziar Arjomandi, Benjamin S. Cazzolato

Abstract:

The turbulence within the atmospheric boundary layer induces highly unsteady aerodynamic loads on structures. These loads, if not accounted for in the design process, will lead to structural failure and are therefore important for the design of the structures. For an accurate prediction of wind loads, understanding the correlation between atmospheric turbulence and the aerodynamic loads is necessary. The aim of this study is to investigate the effect of turbulence within the atmospheric boundary layer on the surface pressure on a flat plate over a wide range of turbulence intensities and integral length scales. The flat plate is chosen as a fundamental geometry which represents structures such as solar panels and billboards. Experiments were conducted at the University of Adelaide large-scale wind tunnel. Two wind tunnel boundary layers with different intensities and length scales of turbulence were generated using two sets of spires with different dimensions and a fetch of roughness elements. Average longitudinal turbulence intensities of 13% and 26% were achieved in each boundary layer, and the longitudinal integral length scale within the three boundary layers was between 0.4 m and 1.22 m. The pressure distributions on a square flat plate at different elevation angles between 30° and 90° were measured within the two boundary layers with different turbulence intensities and integral length scales. It was found that the peak pressure coefficient on the flat plate increased with increasing turbulence intensity and integral length scale. For example, the peak pressure coefficient on a flat plate elevated at 90° increased from 1.2 to 3 with increasing turbulence intensity from 13% to 26%. Furthermore, both the mean and the peak pressure distribution on the flat plates varied with turbulence intensity and length scale. The results of this study can be used to provide a more accurate estimation of the unsteady wind loads on structures such as buildings and solar panels.

Keywords: atmospheric boundary layer, flat plate, pressure coefficient, turbulence

Procedia PDF Downloads 133
2498 A Fuzzy Inference Tool for Assessing Cancer Risk from Radiation Exposure

Authors: Bouharati Lokman, Bouharati Imen, Bouharati Khaoula, Bouharati Oussama, Bouharati Saddek

Abstract:

Ionizing radiation exposure is an established cancer risk factor. Compared to other common environmental carcinogens, it is relatively easy to determine organ-specific radiation dose and, as a result, radiation dose-response relationships tend to be highly quantified. Nevertheless, there can be considerable uncertainty about questions of radiation-related cancer risk as they apply to risk protection and public policy, and the interpretations of interested parties can differ from one person to another. Examples of tools used in the analysis of the risk of developing cancer due to radiation are characterized by uncertainty. These uncertainties are related to the history of exposure and different assumptions involved in the calculation. We believe that the results of statistical calculations are characterized by uncertainty and imprecision. Having regard to the physiological variation from one person to another. In this study, we develop a tool based on fuzzy logic inference. As fuzzy logic deals with imprecise and uncertain, its application in this area is adequate. We propose a fuzzy system with three input variables (age, sex and body attainable cancer). The output variable expresses the risk of infringement rate of each organ. A base rule is established from recorded actual data. After successful simulation, this will instantly predict the risk of infringement rate of each body following chronic exposure to 0.1 Gy.

Keywords: radiation exposure, cancer, modeling, fuzzy logic

Procedia PDF Downloads 305
2497 X-Ray Detector Technology Optimization in Computed Tomography

Authors: Aziz Ikhlef

Abstract:

Most of multi-slices Computed Tomography (CT) scanners are built with detectors composed of scintillator - photodiodes arrays. The photodiodes arrays are mainly based on front-illuminated technology for detectors under 64 slices and on back-illuminated photodiode for systems of 64 slices or more. The designs based on back-illuminated photodiodes were being investigated for CT machines to overcome the challenge of the higher number of runs and connection required in front-illuminated diodes. In backlit diodes, the electronic noise has already been improved because of the reduction of the load capacitance due to the routing reduction. This is translated by a better image quality in low signal application, improving low dose imaging in large patient population. With the fast development of multi-detector-rows CT (MDCT) scanners and the increasing number of examinations, the clinical community has raised significant concerns on radiation dose received by the patient in both medical and regulatory community. In order to reduce individual exposure and in response to the recommendations of the International Commission on Radiological Protection (ICRP) which suggests that all exposures should be kept as low as reasonably achievable (ALARA), every manufacturer is trying to implement strategies and solutions to optimize dose efficiency and image quality based on x-ray emission and scanning parameters. The added demands on the CT detector performance also comes from the increased utilization of spectral CT or dual-energy CT in which projection data of two different tube potentials are collected. One of the approaches utilizes a technology called fast-kVp switching in which the tube voltage is switched between 80 kVp and 140 kVp in fraction of a millisecond. To reduce the cross-contamination of signals, the scintillator based detector temporal response has to be extremely fast to minimize the residual signal from previous samples. In addition, this paper will present an overview of detector technologies and image chain improvement which have been investigated in the last few years to improve the signal-noise ratio and the dose efficiency CT scanners in regular examinations and in energy discrimination techniques. Several parameters of the image chain in general and in the detector technology contribute in the optimization of the final image quality. We will go through the properties of the post-patient collimation to improve the scatter-to-primary ratio, the scintillator material properties such as light output, afterglow, primary speed, crosstalk to improve the spectral imaging, the photodiode design characteristics and the data acquisition system (DAS) to optimize for crosstalk, noise and temporal/spatial resolution.

Keywords: computed tomography, X-ray detector, medical imaging, image quality, artifacts

Procedia PDF Downloads 192
2496 Comparison of Analgesic Efficacy of Paracetamol and Tramadol for Pain Relief in Active Labor

Authors: Krishna Dahiya

Abstract:

Introduction: Labour pain has been described as the most severe pain experienced by women in their lives. Pain management in labour is one of the most important challenges faced by the obstetrician. The opioids are the primary treatment for patients with moderate and severe pain but these drugs are not always tolerated and are associated with dose-dependent side effects. Nonsteroidal anti-inflammatory drugs, too, are associated with variable adverse effects. Considering these factors, our study compared the efficacy and side effect of intravenous tramadol and paracetamol. Objective: To evaluate the efficacy and adverse effects of an intravenous infusion of 1000 mg of paracetamol as compared with an intravenous injection of 50mg of tramadol for intrapartum analgesia. Methods: In a randomized prospective study at Pt. BDS PGIMS, 200 women in active labor were allocated to received either paracetamol (n=100) or tramadol (n=100). The primary outcome was the efficacy of the drug to supply adequate analgesia as measured by a change in the visual analog scale (VAS) pain intensity score at various times after drug administration. The secondary outcomes included the need for additional rescue analgesia and the presence of adverse maternal or fetal events. Results: The mean age of cases were 25.55 ± 3.849 years and 25.60 ± 3.655 years respectively As recorded by the VAS score, there was significant pain reduction at 30 minutes, and at 1 and 2 hours in both groups (P<0.01). In comparison, between group I and II, a significantly higher rate of nausea and vomiting in tramadol group (14% vs 8%; P < 0.03) patients. Similarly, drowsiness (0% vs 11%; P<0.01), dry mouth (0% vs 8%; P<0.04) and dizziness (0% vs 9%; P<0.02) was also significant in group II. Conclusion: Due to difficulty in administering epidural analgesia to all parturients, administration of paracetamol and tramadol infusion for analgesia is simple and less invasive alternative. In the present study, both paracetamol and tramadol were equally effective for labour analgesia but paracetamol has emerged as safe alternative as compared to tramadol due to a low incidence of side effects.

Keywords: paracetamol, tramadol, labor, analgesia

Procedia PDF Downloads 287
2495 Quality Control Assessment of X-Ray Equipment in Hospitals of Katsina State, Nigeria

Authors: Aminu Yakubu Umar

Abstract:

X-ray is the major contributor to the effective dose of both the patient and the personnel. Because of the radiological risks involved, it is usually recommended that dose to patient from X-ray be kept as low as reasonably achievable (ALARA) with adequate image quality. The implementation of quality assurance in diagnostic radiology can help greatly in achieving that, as it is a technique designed to reduce X-ray doses to patients undergoing radiological examination. In this study, quality control was carried out in six hospitals, which involved KVp test, evaluation of total filtration, test for constancy of radiation output, and check for mA linearity. Equipment used include KVp meter, Rad-check meter, aluminum sheets (0.1–1.0 mm) etc. The results of this study indicate that, the age of the X-ray machines in the hospitals ranges from 3-13 years, GHI and GH2 being the oldest and FMC being the newest. In the evaluation of total filtration, the HVL of the X-ray machines in the hospitals varied, ranging from 2.3-5.2 mm. The HVL was found to be highest in AHC (5.2 mm), while it was lowest in GH3 (2.3 mm). All HVL measurements were done at 80 KVp. The variation in voltage accuracy in the hospitals ranges from 0.3%-127.5%. It was only in GH1 that the % variation was below the allowed limit. The test for constancy of radiation output showed that, the coefficient of variation ranges from 0.005–0.550. In GH3, FMC and AHC, the coefficient of linearity were less than the allowed limit, while in GH1, GH2 and GH4 the coefficient of linearity had exceeded the allowed limit. As regard to mA linearity, FMC and AHC had their coefficients of linearity as 0.12 and 0.10 respectively, which were within the accepted limit, while GH1, GH3 and GH4 had their coefficients as 0.16, 0.69 and 0.98 respectively, which exceeded the allowed limit.

Keywords: radiation, X-ray output, quality control, half-value layer, mA linearity, KVp variation

Procedia PDF Downloads 605