Search results for: refractive surgery
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1235

Search results for: refractive surgery

485 Piezosurgery in Periodontics and Oral Implantology

Authors: Neelesh Papineni

Abstract:

Aim: Piezosurgery is a relatively new technique for osteotomy and osteoplasty that uses ultrasonic vibration. The conventional method of treating periodontal cases are by conventional surgeries. However, in this advancing field the use of motor-driven instruments is being considered less invasive. Out of these motor-driven instruments, piezo-electric device has been introduced to the field of periodontics and oral implantology. This article discusses about the wide range of application of piezo-electric device in periodontology, its advantages over conventional surgical therapies and other motor-driven instruments. Results: Piezo- electric has shown better results in aspect of osteotomy, osteoplasty, implants, and any procedure which includes conserving the bone. Also piezo-electric does not cause any kind of damage to the surrounding soft tissue and eliminates the risk of bone necrosis which is a risk factor in other motor driven instruments. Conclusion: In this era of modern dentistry , a successful periodontal and implant surgery requires a sound osseous support. This review gives a pictorial representation about the wide range of application of piezo-electric device in periodontology.

Keywords: piezo-electric, osteotomy, osteoplasty, implantology

Procedia PDF Downloads 371
484 Mental Health and Well-Being: Capacity Building of Community to Respond to Mental Health Needs of Transgender Populations

Authors: Harjyot Khosa

Abstract:

In India and south Asia, stigma and discrimination against transgender community remain disproportionately high. Lack of mental health care restricts effective treatment and care for both physical and mental health. Knowledge assessment of 80 counsellors across India reflected that only 28% counsellors knew about the transgender community. Whereas, only 6% of them felt, that transgender community require a specific mental health support, considering the stigma they face in day to day life. Lastly, 62% did agree that they require specific training to address unmet needs of transgender community. A robust counselling module was developed with focus on technical counselling skills and strategies, specific counselling issues, identity and sexuality, disclosure, hormone therapy and sex reassignment surgery. Mental health related support should be an integral part of government and non-government programs for the overall well-being of transgender community who face stigma and discrimination at every level. Needs based capacity building and technical assistance is required towards providing mental health support for transgender populations and their partners.

Keywords: identity and sexuality, mental health, stigma, transgender

Procedia PDF Downloads 545
483 Experience in Caring for a Patient with Terminal Aortic Dissection of Lung Cancer and Paralysis of the Lower Limbs after Surgery

Authors: Pei-Shan Liang

Abstract:

Objective: This article explores the care experience of a terminal lung cancer patient who developed lower limb paralysis after surgery for aortic dissection. The patient, diagnosed with aortic dissection during chemotherapy for lung cancer, faced post-surgical lower limb paralysis, leading to feelings of helplessness and hopelessness as they approached death with reduced mobility. Methods: The nursing period was from July 19 to July 27, during which the author, alongside the intensive care team and palliative care specialists, conducted a comprehensive assessment through observation, direct care, conversations, physical assessments, and medical record review. Gordon's eleven functional health patterns were used for a holistic evaluation, identifying four nursing health issues: "pain related to terminal lung cancer and invasive procedures," "decreased cardiac tissue perfusion due to hemodynamic instability," "impaired physical mobility related to lower limb paralysis," and "hopelessness due to the unpredictable prognosis of terminal lung cancer." Results: The medical team initially focused on symptom relief, administering Morphine 5mg in 0.9% N/S 50ml IVD q6h for pain management and continuing chemotherapy as prescribed. Open communication was employed to address the patient's physical, psychological, and spiritual concerns. Non-pharmacological interventions, including listening, caring, companionship, opioid medication, and distraction techniques like comfortable positioning and warm foot baths, were used to alleviate pain, reducing the pain score to 3 on the numeric rating scale and easing respiratory discomfort. The palliative care team was also involved, guiding the patient and family through the "Four Paths of Life," helping the patient achieve a good end-of-life experience and the family to experience a peaceful life. This process also served to promote the concept of palliative care, enabling more patients and families to receive high-quality and dignified care. The patient was encouraged to express inner anxiety through drawing or writing, which helped reduce the hopelessness caused by psychological distress and uncertainty about the disease's prognosis, as assessed by the Hospital Anxiety and Depression Scale, reaching a level of mild anxiety but acceptable without affecting sleep. Conclusion: What left a deep impression during the care process was the need for intensive care providers to consider the patient's psychological state, not just their physical condition, when the patient's situation changes. Family support and involvement often provide the greatest solace for the patient, emphasizing the importance of comfort and dignity. This includes oral care to maintain cleanliness and comfort, frequent repositioning to alleviate pressure and discomfort, and timely removal of invasive devices and unnecessary medications to avoid unnecessary suffering. The nursing process should also address the patient's psychological needs, offering comfort and support to ensure that they can face the end of life with peace and dignity.

Keywords: intensive care, lung cancer, aortic dissection, lower limb paralysis

Procedia PDF Downloads 14
482 Clinical Pathway for Postoperative Organ Transplants

Authors: Tahsien Okasha

Abstract:

Transplantation medicine is one of the most challenging and complex areas of modern medicine. Some of the key areas for medical management are the problems of transplant rejection, during which the body has an immune response to the transplanted organ, possibly leading to transplant failure and the need to immediately remove the organ from the recipient. When possible, transplant rejection can be reduced through serotyping to determine the most appropriate donor-recipient match and through the use of immunosuppressant drugs. Postoperative care actually begins before the surgery in terms of education, discharge planning, nutrition, pulmonary rehabilitation, and patient/family education. This also allows for expectations to be managed. A multidisciplinary approach is the key, and collaborative team meetings are essential to ensuring that all team members are "on the same page.". The following clinical pathway map and guidelines with the aim to decrease alteration in clinical practice and are intended for those healthcare professionals who look after organ transplant patients. They are also intended to be useful to both medical and surgical trainees as well as nurse specialists and other associated healthcare professionals involved in the care of organ transplant patients. This pathway is general pathway include the general guidelines that can be applicable for all types of organ transplant with special considerations to each organ.

Keywords: organ transplant, clinical pathway, postoperative care, same page

Procedia PDF Downloads 432
481 The Effect of Exercise Therapy and Electroacupuncture on Some Clinical Outcomes in People with Post Total Hip Arthroplasty

Authors: Marzieh Yassin, Masoud Rashed, Soheil Mansour Sohani, Reza Salehi

Abstract:

Background: Hip arthroplasty is one of the surgical methods to improve symptoms in patients with hip osteoarthritis. The use of electroacupuncture and TENS reduces pain, increases range of motion and improves performance. Methods: In this clinical trial study, 30 patients after hip arthroplasty were randomly divided into two groups: electroacupuncture (n=16) with exercise therapy and TENS with exercise therapy (n=14). Severity of pain, quality of life, range of motion, edema and function were evaluated in two groups before and after the interventions. Interventions of 10 sessions (three sessions per week) were conducted for two groups. The significance level in all tests was below 0.05. Results: The results showed that both groups improved all of the symptoms after the intervention (p≤0.05), although there was no statistically significant difference between the two groups in terms of effectiveness (p≥0.05). Conclusion: The results showed that both methods improve symptoms in patients after surgery. According to this study, electroacupuncture is suggested as a new method effective for the treatment of people with post-Total Hip Arthroplasty.

Keywords: electroacupuncture, physical performance, total hip arthroplasty, TENS

Procedia PDF Downloads 76
480 Clinical Pathway for Postoperative Organ Transplantation

Authors: Tahsien Okasha

Abstract:

Transplantation medicine is one of the most challenging and complex areas of modern medicine. Some of the key areas for medical management are the problems of transplant rejection, during which the body has an immune response to the transplanted organ, possibly leading to transplant failure and the need to immediately remove the organ from the recipient. When possible, transplant rejection can be reduced through serotyping to determine the most appropriate donor-recipient match and through the use of immunosuppressant drugs. Postoperative care actually begins before the surgery in terms of education, discharge planning, nutrition, pulmonary rehabilitation, and patient/family education. This also allows for expectations to be managed. A multidisciplinary approach is the key, and collaborative team meetings are essential to ensuring that all team members are "on the same page." .The following clinical pathway map and guidelines with the aim to decrease alteration in clinical practice and are intended for those healthcare professionals who look after organ transplant patients. They are also intended to be useful to both medical and surgical trainees as well as nurse specialists and other associated healthcare professionals involved in the care of organ transplant patients. This pathway is general pathway include the general guidelines that can be applicable for all types of organ transplant with special considerations to each organ.

Keywords: postoperative care, organ transplant, clinical pathway, patient

Procedia PDF Downloads 451
479 O-(2-18F-Fluoroethyl)-L-Tyrosine Positron Emission Tomography/Computed Tomography in Patients with Suspicious Recurrent Low and High-Grade Glioma

Authors: Mahkameh Asadi, Habibollah Dadgar

Abstract:

The precise definition margin of high and low-grade glioma is crucial for choosing best treatment approach after surgery and radio-chemotherapy. The aim of the current study was to assess the O-(2-18F-fluoroethyl)-L-tyrosine (18F-FET) positron emission tomography (PET)/computed tomography (CT) in patients with low (LGG) and high grade glioma (HGG). We retrospectively analyzed 18F-FET PET/CT of 10 patients (age: 33 ± 12 years) with suspicious for recurrent LGG and HGG. The final decision of recurrence was made by magnetic resonance imaging (MRI) and registered clinical data. While response to radio-chemotherapy by MRI is often complex and sophisticated due to the edema, necrosis, and inflammation, emerging amino acid PET leading to better interpretations with more specifically differentiate true tumor boundaries from equivocal lesions. Therefore, integrating amino acid PET in the management of glioma to complement MRI will significantly improve early therapy response assessment, treatment planning, and clinical trial design.

Keywords: positron emission tomography, amino acid positron emission tomography, magnetic resonance imaging, low and high grade glioma

Procedia PDF Downloads 169
478 Lung Cancer Patients in Eastern Region of Nepal

Authors: Ram Sharan Mehta

Abstract:

The number of new cancer cases annually is estimated to rise from 10.9 million in 2002 to more than 16 million by 2020, if current trends continue. Much of this increase in absolute numbers derives from the ageing of populations worldwide. The objectives of this study were to find out the demographic characteristics of the admitted cancer patients in BPKIHS. It was hospital based descriptive cross-sectional study conducted reviewing all the records of admitted diagnosed cancer patients in BPKIHS from 15th October 2004 to 14th October 2012. Using total enumerative sampling technique all 1379 diagnosed cancer patients record were reviewed after obtaining the permission from concerned authorities. Using SPSS-15 software package data was analyzed. It was found that majority (71%) of cancer patients were of age more than 40 years and equal of both sexes. Most of the clients were form Sunsari (31.1%), Morang (16.6%) and Jhapa (17%) districts. The mean hospitalization day is 8.32 and very few patients (5.2%) were only cured. The numbers of cancer patients are markedly increases in BPKIHS, especially in advanced stage. It is mandatory to start the cancer information and education programme in eastern region of Nepal and proper management of cancer patients using chemotherapy, radiotherapy and surgery at BPKIHS for quality patient care.

Keywords: lung, cancer, patients, Nepal

Procedia PDF Downloads 369
477 Raman Spectral Fingerprints of Healthy and Cancerous Human Colorectal Tissues

Authors: Maria Karnachoriti, Ellas Spyratou, Dimitrios Lykidis, Maria Lambropoulou, Yiannis S. Raptis, Ioannis Seimenis, Efstathios P. Efstathopoulos, Athanassios G. Kontos

Abstract:

Colorectal cancer is the third most common cancer diagnosed in Europe, according to the latest incidence data provided by the World Health Organization (WHO), and early diagnosis has proved to be the key in reducing cancer-related mortality. In cases where surgical interventions are required for cancer treatment, the accurate discrimination between healthy and cancerous tissues is critical for the postoperative care of the patient. The current study focuses on the ex vivo handling of surgically excised colorectal specimens and the acquisition of their spectral fingerprints using Raman spectroscopy. Acquired data were analyzed in an effort to discriminate, in microscopic scale, between healthy and malignant margins. Raman spectroscopy is a spectroscopic technique with high detection sensitivity and spatial resolution of few micrometers. The spectral fingerprint which is produced during laser-tissue interaction is unique and characterizes the biostructure and its inflammatory or cancer state. Numerous published studies have demonstrated the potential of the technique as a tool for the discrimination between healthy and malignant tissues/cells either ex vivo or in vivo. However, the handling of the excised human specimens and the Raman measurement conditions remain challenging, unavoidably affecting measurement reliability and repeatability, as well as the technique’s overall accuracy and sensitivity. Therefore, tissue handling has to be optimized and standardized to ensure preservation of cell integrity and hydration level. Various strategies have been implemented in the past, including the use of balanced salt solutions, small humidifiers or pump-reservoir-pipette systems. In the current study, human colorectal specimens of 10X5 mm were collected from 5 patients up to now who underwent open surgery for colorectal cancer. A novel, non-toxic zinc-based fixative (Z7) was used for tissue preservation. Z7 demonstrates excellent protein preservation and protection against tissue autolysis. Micro-Raman spectra were recorded with a Renishaw Invia spectrometer from successive random 2 micrometers spots upon excitation at 785 nm to decrease fluorescent background and secure avoidance of tissue photodegradation. A temperature-controlled approach was adopted to stabilize the tissue at 2 °C, thus minimizing dehydration effects and consequent focus drift during measurement. A broad spectral range, 500-3200 cm-1,was covered with five consecutive full scans that lasted for 20 minutes in total. The average spectra were used for least square fitting analysis of the Raman modes.Subtle Raman differences were observed between normal and cancerous colorectal tissues mainly in the intensities of the 1556 cm-1 and 1628 cm-1 Raman modes which correspond to v(C=C) vibrations in porphyrins, as well as in the range of 2800-3000 cm-1 due to CH2 stretching of lipids and CH3 stretching of proteins. Raman spectra evaluation was supported by histological findings from twin specimens. This study demonstrates that Raman spectroscopy may constitute a promising tool for real-time verification of clear margins in colorectal cancer open surgery.

Keywords: colorectal cancer, Raman spectroscopy, malignant margins, spectral fingerprints

Procedia PDF Downloads 90
476 Balanced Ischemia Misleading to a False Negative Myocardial Perfusion Imaging (Stress) Test

Authors: Devam Sheth

Abstract:

Nuclear imaging with stress myocardial perfusion (stress test) is the preferred first line investigation for noninvasive evaluation of ischaemic heart condition. The sensitivity of this test is close to 90 % making it a very reliable test. However, rarely it gives a false negative result which can be explained by the phenomenon termed as “balanced ischaemia”. We present the case of a 78 year Caucasian female without any significant past cardiac history, who presents with chest pain and shortness of breath since one day. The initial ECG and cardiac enzymes were non-impressive. Few hours later, she had some substernal chest pain along with some ST segment depression in the lateral leads. Stress test comes back negative for any significant perfusion defects. However, given her typical symptoms, she underwent a cardiac catheterization which revealed significant triple vessel disease mandating her to get a bypass surgery. This unusual phenomenon of false nuclear stress test in the setting of positive ECG changes can be explained only by balanced ischemia wherein due to global myocardial ischemia, the stress test fails to reveal relative perfusion defects in the affected segments.

Keywords: balanced, false positive, ischemia, myocardial perfusion imaging

Procedia PDF Downloads 298
475 Task Evoked Pupillary Response for Surgical Task Difficulty Prediction via Multitask Learning

Authors: Beilei Xu, Wencheng Wu, Lei Lin, Rachel Melnyk, Ahmed Ghazi

Abstract:

In operating rooms, excessive cognitive stress can impede the performance of a surgeon, while low engagement can lead to unavoidable mistakes due to complacency. As a consequence, there is a strong desire in the surgical community to be able to monitor and quantify the cognitive stress of a surgeon while performing surgical procedures. Quantitative cognitiveload-based feedback can also provide valuable insights during surgical training to optimize training efficiency and effectiveness. Various physiological measures have been evaluated for quantifying cognitive stress for different mental challenges. In this paper, we present a study using the cognitive stress measured by the task evoked pupillary response extracted from the time series eye-tracking measurements to predict task difficulties in a virtual reality based robotic surgery training environment. In particular, we proposed a differential-task-difficulty scale, utilized a comprehensive feature extraction approach, and implemented a multitask learning framework and compared the regression accuracy between the conventional single-task-based and three multitask approaches across subjects.

Keywords: surgical metric, task evoked pupillary response, multitask learning, TSFresh

Procedia PDF Downloads 140
474 Engineering Topology of Photonic Systems for Sustainable Molecular Structure: Autopoiesis Systems

Authors: Moustafa Osman Mohammed

Abstract:

This paper introduces topological order in descried social systems starting with the original concept of autopoiesis by biologists and scientists, including the modification of general systems based on socialized medicine. Topological order is important in describing the physical systems for exploiting optical systems and improving photonic devices. The stats of topological order have some interesting properties of topological degeneracy and fractional statistics that reveal the entanglement origin of topological order, etc. Topological ideas in photonics form exciting developments in solid-state materials, that being; insulating in the bulk, conducting electricity on their surface without dissipation or back-scattering, even in the presence of large impurities. A specific type of autopoiesis system is interrelated to the main categories amongst existing groups of the ecological phenomena interaction social and medical sciences. The hypothesis, nevertheless, has a nonlinear interaction with its natural environment 'interactional cycle' for exchange photon energy with molecules without changes in topology. The engineering topology of a biosensor is based on the excitation boundary of surface electromagnetic waves in photonic band gap multilayer films. The device operation is similar to surface Plasmonic biosensors in which a photonic band gap film replaces metal film as the medium when surface electromagnetic waves are excited. The use of photonic band gap film offers sharper surface wave resonance leading to the potential of greatly enhanced sensitivity. So, the properties of the photonic band gap material are engineered to operate a sensor at any wavelength and conduct a surface wave resonance that ranges up to 470 nm. The wavelength is not generally accessible with surface Plasmon sensing. Lastly, the photonic band gap films have robust mechanical functions that offer new substrates for surface chemistry to understand the molecular design structure and create sensing chips surface with different concentrations of DNA sequences in the solution to observe and track the surface mode resonance under the influences of processes that take place in the spectroscopic environment. These processes led to the development of several advanced analytical technologies: which are; automated, real-time, reliable, reproducible, and cost-effective. This results in faster and more accurate monitoring and detection of biomolecules on refractive index sensing, antibody-antigen reactions with a DNA or protein binding. Ultimately, the controversial aspect of molecular frictional properties is adjusted to each other in order to form unique spatial structure and dynamics of biological molecules for providing the environment mutual contribution in investigation of changes due to the pathogenic archival architecture of cell clusters.

Keywords: autopoiesis, photonics systems, quantum topology, molecular structure, biosensing

Procedia PDF Downloads 87
473 Intrathecal Fentanyl with 0.5% Bupivacaine Heavy in Chronic Opium Abusers

Authors: Suneet Kathuria, Shikha Gupta, Kapil Dev, Sunil Katyal

Abstract:

Chronic use of opioids in opium abusers can cause poor pain control and increased analgaesic requirement. We compared the duration of spinal anaesthesia in chronic opium abusers and non-abusers. This prospective randomised study included 60 American Society of Anesthesiologists (ASA) Grade I or II adults undergoing surgery under spinal anaesthesia with 10 mg bupivacaine, and 25 μg fentanyl in non-opium abusers (Group A); and chronic opium abusers (Group B), and 40 μg fentanyl in chronic opium abusers (Group C). Patients were assessed for onset and duration of sensory and motor blockade and duration of effective analgesia. Mean time to onset of adequate analgesia in opium abusers was significantly longer in chronic opium abusers than in opium-naive patients. The duration of sensory block and motor block was significantly less in chronic opium abusers than in non-opium abusers. Duration of effective analgesia in groups A, B and C was 255.55 ± 26.84, 217.85 ± 15.15, and 268.20 ± 18.25 minutes, respectively; this difference was statistically significant. In chronic opium abusers, the duration of spinal anaesthesia is significantly shorter than that in opium nonabusers. The duration of spinal anaesthesia with bupivacaine and fentanyl in chronic opium abusers can be improved by increasing the intrathecal fentanyl dose from 25 μg to 40 μg.

Keywords: bupivacaine, chronic opium abusers, fentanyl, intrathecal

Procedia PDF Downloads 291
472 Waveguiding in an InAs Quantum Dots Nanomaterial for Scintillation Applications

Authors: Katherine Dropiewski, Michael Yakimov, Vadim Tokranov, Allan Minns, Pavel Murat, Serge Oktyabrsky

Abstract:

InAs Quantum Dots (QDs) in a GaAs matrix is a well-documented luminescent material with high light yield, as well as thermal and ionizing radiation tolerance due to quantum confinement. These benefits can be leveraged for high-efficiency, room temperature scintillation detectors. The proposed scintillator is composed of InAs QDs acting as luminescence centers in a GaAs stopping medium, which also acts as a waveguide. This system has appealing potential properties, including high light yield (~240,000 photons/MeV) and fast capture of photoelectrons (2-5ps), orders of magnitude better than currently used inorganic scintillators, such as LYSO or BaF2. The high refractive index of the GaAs matrix (n=3.4) ensures light emitted by the QDs is waveguided, which can be collected by an integrated photodiode (PD). Scintillation structures were grown using Molecular Beam Epitaxy (MBE) and consist of thick GaAs waveguiding layers with embedded sheets of modulation p-type doped InAs QDs. An AlAs sacrificial layer is grown between the waveguide and the GaAs substrate for epitaxial lift-off to separate the scintillator film and transfer it to a low-index substrate for waveguiding measurements. One consideration when using a low-density material like GaAs (~5.32 g/cm³) as a stopping medium is the matrix thickness in the dimension of radiation collection. Therefore, luminescence properties of very thick (4-20 microns) waveguides with up to 100 QD layers were studied. The optimization of the medium included QD shape, density, doping, and AlGaAs barriers at the waveguide surfaces to prevent non-radiative recombination. To characterize the efficiency of QD luminescence, low temperature photoluminescence (PL) (77-450 K) was measured and fitted using a kinetic model. The PL intensity degrades by only 40% at RT, with an activation energy for electron escape from QDs to the barrier of ~60 meV. Attenuation within the waveguide (WG) is a limiting factor for the lateral size of a scintillation detector, so PL spectroscopy in the waveguiding configuration was studied. Spectra were measured while the laser (630 nm) excitation point was scanned away from the collecting fiber coupled to the edge of the WG. The QD ground state PL peak at 1.04 eV (1190 nm) was inhomogeneously broadened with FWHM of 28 meV (33 nm) and showed a distinct red-shift due to self-absorption in the QDs. Attenuation stabilized after traveling over 1 mm through the WG, at about 3 cm⁻¹. Finally, a scintillator sample was used to test detection and evaluate timing characteristics using 5.5 MeV alpha particles. With a 2D waveguide and a small area of integrated PD, the collected charge averaged 8.4 x10⁴ electrons, corresponding to a collection efficiency of about 7%. The scintillation response had 80 ps noise-limited time resolution and a QD decay time of 0.6 ns. The data confirms unique properties of this scintillation detector which can be potentially much faster than any currently used inorganic scintillator.

Keywords: GaAs, InAs, molecular beam epitaxy, quantum dots, III-V semiconductor

Procedia PDF Downloads 253
471 Comparative Analysis of Patent Protection between Health System and Enterprises in Shanghai, China

Authors: Na Li, Yunwei Zhang, Yuhong Niu

Abstract:

The study discussed the patent protections of health system and enterprises in Shanghai. The comparisons of technical distribution and scopes of patent protections between Shanghai health system and enterprises were used by the methods of IPC classification, co-words analysis and visual social network. Results reflected a decreasing order within IPC A61 area, namely A61B, A61K, A61M, and A61F. A61B required to be further investigated. The highest authorized patents A61B17 of A61B of IPC A61 area was found. Within A61B17, fracture fixation, ligament reconstruction, cardiac surgery, and biopsy detection were regarded as common concerned fields by Shanghai health system and enterprises. However, compared with cardiac closure which Shanghai enterprises paid attention to, Shanghai health system was more inclined to blockages and hemostatic tools. The results also revealed that the scopes of patent protections of Shanghai enterprises were relatively centralized. Shanghai enterprises had a series of comprehensive strategies for protecting core patents. In contrast, Shanghai health system was considered to be lack of strategic patent protections for core patents.

Keywords: co-words analysis, IPC classification, patent protection, technical distribution

Procedia PDF Downloads 131
470 Sensitivity Improvement of Optical Ring Resonator for Strain Analysis with the Direction of Strain Recognition Possibility

Authors: Tayebeh Sahraeibelverdi, Ahmad Shirazi Hadi Veladi, Mazdak Radmalekshah

Abstract:

Optical sensors became attractive due to preciseness, low power consumption, and intrinsic electromagnetic interference-free characteristic. Among the waveguide optical sensors, cavity-based ones attended for the high Q-factor. Micro ring resonators as a potential platform have been investigated for various applications as biosensors to pressure sensors thanks to their sensitive ring structure responding to any small change in the refractive index. Furthermore, these small micron size structures can come in an array, bringing the opportunity to have any of the resonance in a specific wavelength and be addressed in this way. Another exciting application is applying a strain to the ring and making them an optical strain gauge where the traditional ones are based on the piezoelectric material. Making them in arrays needs electrical wiring and about fifty times bigger in size. Any physical element that impacts the waveguide cross-section, Waveguide elastic-optic property change, or ring circumference can play a role. In comparison, ring size change has a larger effect than others. Here an engineered ring structure is investigated to study the strain effect on the ring resonance wavelength shift and its potential for more sensitive strain devices. At the same time, these devices can measure any strain by mounting on the surface of interest. The idea is to change the" O" shape ring to a "C" shape ring with a small opening starting from 2π/360 or one degree. We used the Mode solution of Lumbrical software to investigate the effect of changing the ring's opening and the shift induced by applied strain. The designed ring radius is a three Micron silicon on isolator ring which can be fabricated by standard complementary metal-oxide-semiconductor (CMOS) micromachining. The measured wavelength shifts from1-degree opening of the ring to a 6-degree opening have been investigated. Opening the ring for 1-degree affects the ring's quality factor from 3000 to 300, showing an order of magnitude Q-factor reduction. Assuming a strain making the ring-opening from 1 degree to 6 degrees, our simulation results showing negligible Q-factor reduction from 300 to 280. A ring resonator quality factor can reach up to 108 where an order of magnitude reduction is negligible. The resonance wavelength shift showed a blue shift and was obtained to be 1581, 1579,1578,1575nm for 1-, 2-, 4- and 6-degree ring-opening, respectively. This design can find the direction of the strain-induced by applying the opening on different parts of the ring. Moreover, by addressing the specified wavelength, we can precisely find the direction. We can open a significant opportunity to find cracks and any surface mechanical property very specifically and precisely. This idea can be implemented on polymer ring resonators while they can come with a flexible substrate and can be very sensitive to any strain making the two ends of the ring in the slit part come closer or further.

Keywords: optical ring resonator, strain gauge, strain sensor, surface mechanical property analysis

Procedia PDF Downloads 121
469 Air Conditioner Refrigerant and Burn: A Case Report

Authors: Okan Cakir, Ibrahim Arziman, Derya Can, Mete Erkencigil, Murat Durusu, S. Mehmet Yasar

Abstract:

Introduction: Burn injuries from different types and ways commonly seen in emergency departments, approach and treatment varies from outpatient treatment to critical care unit. We wanted to mention a rare burn injury cause of air conditioner refrigerant. Case report: A 22-year-old case admitted to emergency department with a complaint of left hand burn injury and pain. In his history, he said that an accident was occurred before 30 minutes from admission while he had been trying to repair the air conditioner. Air conditioner refrigerant suddenly had erupted from its tank and burned his hand. In physical examination of extremities, second-degree burn bullae on the left hand on second and third proximal phalanx, between first and second phalanx palmar side and on hypothenar region and on third and fourth proximal phalanx and also hyperemia from hand to wrist were seen. There was no motor and sensorial deficiency. As a treatment, local silver sulfadiazine applied to the burn area and analgesic prescribed. The case called for the clinical follow-up to the plastic surgery department. Conclusion: The clinician should take a comprehensive and careful anamnesis for suitable and right management and treatment as in this case in which as well as rare and occurs different way.

Keywords: air conditioner refrigerant, burn, emergency department, rare

Procedia PDF Downloads 339
468 Aristotle University of Thessaloniki

Authors: Ail Akbar Emamverdian, Neriman Özada, Atabak Rahimzadeh Ilkhchi, Zahra Emamverdian

Abstract:

The reverse shoulder prosthesis is an innovative procedure design to treat of (GH) joint problems with severe rotator cuff deficiency. The original reverse shoulder prosthesis was invented by France surgery in1985 and has been in clinical use in the United States in 2004. These prostheses consist of baseplate that attached to the glenoid, in order to hold a spherical component, and humeral part consist of polyethylene insert which is flat. This prosthesis is the ‘reverse’ configuration. The indications for the reverse prosthesis are: (1) treating failed hemi arthroplasty with irrecoverable rotator cuff tears, (2) relief of painful arthritis associated with cuff tear arthropathy, (3) instauration after tumor resection, (4) pseudo paralysis because of irrecoverable rotator cuff tears (5) some fractures of the shoulder which reverse shoulder prostheses is only the option for treatment. This prosthesis resulting in relief of pain and decreasing the range of motion in above indications. However, this prosthesis and its applications such as notching of the scapula, dislocation of the prosthesis parts and acromial stress fractures. In this article the reverse shoulder prostheses, indication has been reviewed. This study can make clear aspect of reverse shoulder prosthesis that can help to find some solution in future.

Keywords: prostheses, complications, reverse shoulder prosthesis, indications

Procedia PDF Downloads 274
467 Thick Data Analytics for Learning Cataract Severity: A Triplet Loss Siamese Neural Network Model

Authors: Jinan Fiaidhi, Sabah Mohammed

Abstract:

Diagnosing cataract severity is an important factor in deciding to undertake surgery. It is usually conducted by an ophthalmologist or through taking a variety of fundus photography that needs to be examined by the ophthalmologist. This paper carries out an investigation using a Siamese neural net that can be trained with small anchor samples to score cataract severity. The model used in this paper is based on a triplet loss function that takes the ophthalmologist best experience in rating positive and negative anchors to a specific cataract scaling system. This approach that takes the heuristics of the ophthalmologist is generally called the thick data approach, which is a kind of machine learning approach that learn from a few shots. Clinical Relevance: The lens of the eye is mostly made up of water and proteins. A cataract occurs when these proteins at the eye lens start to clump together and block lights causing impair vision. This research aims at employing thick data machine learning techniques to rate the severity of the cataract using Siamese neural network.

Keywords: thick data analytics, siamese neural network, triplet-loss model, few shot learning

Procedia PDF Downloads 104
466 Thyroid-Stimulating Hormone as a Stress Biomarker in Thyroidectomy Patients: A Cohort Study

Authors: Jeonghun Lee

Abstract:

In this study, we investigated the relationship between stress and thyroid dysfunction in such patients who underwent thyroidectomy. This study included 101 patients who underwent thyroidectomy from January 2015 to June 2020 and experienced hypothyroidism. The included patients had good drug compliance with the same dosage of levothyroxine (LT4). The male-to-female ratio was 1:4.6, and the mean age was 45.4 years at surgery and 50.2 years at stressful events. Eighteen patients underwent lobectomies and, of these, 12 did not take LT4. The mean follow-up period was 49(8-93) months. Statistical analyses were performed using the paired t-test, Wilcoxon signed-rank test, and McNemer test using PROC MIXED with SAS 9.4. Forty-five patients (44.6%) had hypothyroidism with thyroid-stimulating hormone (TSH) >10 μIU/mL. There was distress in 81 patients and eustress in 10 patients. TSH levels increased during a mean 5.8 months (min 1, max 12) in 24 patients who specified the date of their life events. Even though each patient took the same dose of LT4, when the patients were under stress, both the free T4 and T3 decreased and TSH increased, regardless of whether the patient experienced distress or eustress (P <0.001). While adjusting for the effect of the free T4 and T3, TSH increased significantly in the patients after stress (P <0.001). For patients with thyroid cancer who are simultaneously experiencing life events, TSH may be used as a stress biomarker to enable the implementation of appropriate treatment and counseling strategies.

Keywords: endocrine, thyroid, thyroid function, biomarker, stress

Procedia PDF Downloads 81
465 The Relationship of the Dentate Nucleus with the Pyramid of Vermis: A Microneurosurgical Anatomical Study

Authors: Santhosh K. S. Annayappa, Nupur Pruthi

Abstract:

The region of dentate nucleus is a common site for various pathologies like hematomas, tumours, etc. We aimed to study in detail the relationship of this region with the vermis, especially the pyramid using microscopic fibre dissection technique. To achieve this aim, 20 cerebellar hemispheres were studied from the 11 cerebellums. Dissection was performed using wooden spatulas and micro dissectors under a microscope following Klingler’s preservation technique. The relationship between the pyramid of vermis and the dentate nucleus was studied in detail. A similar relationship was studied on the MRI of randomly selected trigeminal neuralgia patients and correlated with anatomical findings. Results show the mean distance of the lateral margin of the dentate nucleus from the midline on anatomic specimens was 21.4 ± 1.8 mm (19-25 mm) and 23.4 ± 3.4 mm (15-29 mm) on right and left side, respectively. Similar measurements made on the MRI were 22.97 ± 2.0 mm (20.03-26.15 mm) on the right side and 23.98 ± 2.1 mm (21.47-27.67 mm) on the left side. The amount of white matter dissection required to reach the dentate nucleus at the pyramidal attachment area was 7.3 ± 1.0 mm (6-9 mm) on the right side and 6.8 ± 1.4 mm (5-10 mm) on the left side. It was concluded that the pyramid of vermis has a constant relationship with the dentate nucleus and can be used as an excellent landmark during surgery to localise the dentate nucleus on the suboccipital surface.

Keywords: fiber dissection, micro neurosurgery, the dentate nucleus of cerebellum, the pyramid of vermis

Procedia PDF Downloads 151
464 Fracture Dislocation of Upper Sacrum in an Adolescent: Case Report and Review of Literature

Authors: S. Alireza Mirghasemi, Narges Rahimi Gabaran

Abstract:

Although sacral fractures in children are rare due to the fact that the occurrence of pelvic fracture is not common in childhood. Sacral fractures present a high risk of neurological damage. This kind of fracture is often missed because the routine pelvic X-rays imaging scarcely show this fracture. Also, the treatment is controversial, and it ranges from fine reduction to conservative treatments without any try to reduce the dislocation. In this article, a case of fracture dislocation of S1 and S2 along with a suggested diagnostic test and treatment based on similar cases are presented. The case investigates a 14-year-old boy who entered the hospital one week after a car accident that knocked him to the ground in crawling position and a rack fell down on his body. Pain and tenderness in the sacral region and a fracture in the left leg were notable--we detected incomplete bilateral palsy of L5, S1 and S2 roots. In radiographs of the spine fracture dislocation of S1, the sacral fracture was seen. The treatment included a skeletal traction with a halo over the patient’s head and two femoral pins. After one week, another surgery was performed in order to stabilize and reduce the fracture, and we employed a posterior approach with CD and a pedicular screw. After two years of follow-up, the fracture is completely cured without any loss of reduction.

Keywords: adolescent, fracture in adolescent, fracture dislocation, sacrum

Procedia PDF Downloads 286
463 Low Frequency Sound Intervention: Therapeutic Impact and Applications

Authors: Heidi Ahonen

Abstract:

Since antiquity, many cultures have seemingly known the power of low frequencies, incorporating them in healing practices through drumming, singing, humming, etc. Many music therapists recognize there is something in music that is transformative enough to make a difference in people’s lives. This paper summarizes the key findings of several low-frequency research with various client populations conducted by the author. Utilizing low-frequency sound (30 or 40 Hz) may have diverse therapeutic impacts: (1) Calming effect – decreased agitation (autism, brain injury, AD, dementia) (2) Muscle relaxation (CP & spasticity & pain/after surgery patients, MS, fibromyalgia) (3) Relaxation/stress release (anxiety, stress, PTSD, trauma, insomnia) (4) Muscular/motor functioning/ decrease of tremor (CP, MS, Parkinson) (5) Increase in alertness, cognitive awareness & short-term memory function (brain injury, severe global developmental delay, AD) (6) Increased focus (AD, PTSD, trauma). The paper will conclude by presenting ideas informing the clinical practice. Future studies need to investigate what frequencies are effective for particular client populations and why, what theories can explain the effect, and finally, something that has been long debated - is it auditive or kinaesthetic stimulation or the combination of both that is effective?

Keywords: low frequency, 40 Hz, sound, neuro disability

Procedia PDF Downloads 106
462 Surgical Site Infections Post Ventriculoperitoneal (VP) Shunting: A Matched Healthcare Cost and Length of Stay Study

Authors: Issa M. Hweidi, Saba W. Al-Ibraheem

Abstract:

This study aimed to assess the increased hospital length of stay and healthcare costs associated with SSIs among ventriculoperitoneal shunting surgery patients in Jordan. This study adopted a retrospective and nested 1:1 matched case-control design. A non-probability convenient sample of 48 VP shunt patients was recruited for the purpose of the study. The targeted groups of the study basically used to cross-match the variables investigated to minimize the risk of confounding. Information was extracted from the text of patients' electronic health records. As compared to the non-SSI group, the SSI group had an extra mean healthcare cost of $13,696.53 (p=0.001) and longer hospital length of stay (22.64 mean additional days). Furthermore, Acinetobacter baumannii and Klebsiella pneumonia were identified as being the most predominant causative agents of SSIs. The results of this study may provide baseline data for national and regional benchmarking to evaluate the quality of care provided to likewise patients. Adherence to infection control strategies and protocols considering new surveillance methods of SSIs is encouraged.

Keywords: ventriculoperitoneal shunt, health care cost, length of stay, neurosurgery, surgical site infections

Procedia PDF Downloads 71
461 Case Report: A Rare Presentation of Fowler's Syndrome in Pregnancy with Mitrofanoff Procedure

Authors: Humaira Saeed Malik, Salma Saad

Abstract:

Introduction: Fowler's syndrome, first described by Clare Fowler in 1985, is a rare urological condition characterized by difficulty in urination due to the abnormal function of the urethral sphincter. It predominantly affects young women and leads to chronic urinary retention. The main concern in managing this condition is ensuring regular bladder emptying. Clam cystoplasty is a bladder augmentation surgery in which the bladder is clam-shelled open, and a segment of the intestine is used to increase the bladder's capacity and reduce bladder pressure. The Mitrofanoff procedure, a surgical creation of a continent urinary diversion, is often performed in patients with Fowler's syndrome who require long-term catheterization. This procedure involves creating a conduit (from the appendix or a segment of the small intestine) between the bladder and the skin, allowing for intermittent self-catheterization to manage urinary retention. Study: This case study examines a 39-year-old gravida 3, para 0+2 woman with a BMI of 40, Fowler's syndrome, type I diabetes, and post-traumatic stress disorder (PTSD), presenting at Dumfries and Galloway Royal Infirmary at 8 weeks of gestation. Diagnosed with Fowler's syndrome at 23, . A sacral nerve stimulator (SNS) device was initially placed but was subsequently removed after one year due to malfunction caused by trauma, subsequently she had undergone clam cystoplasty and the Mitrofanoff procedure for bladder management. Her pregnancy was complicated by vaginal bleeding at 10 weeks, treated with progesterone pessaries, and a urinary tract infection at 14 weeks, managed with antibiotics. Despite these challenges, she continued self-catheterization through the Mitrofanoff stoma and was placed on prophylactic antibiotics. Her diabetes was well-controlled on insulin, and a 20-week fetal anomaly scan was normal. The multidisciplinary team, including an obstetrician and a urologist, planned for serial growth scans and the initiation of low molecular weight heparin (LMWH) from 28 weeks due to the intermediate risk of venous thromboembolism (VTE) and to continue six weeks after delivery. A planned cesarean delivery at 37 weeks was arranged, with an MRI scan scheduled later in the pregnancy to assist in surgical planning, ensuring the preservation of the Mitrofanoff stoma's function. The surgery will occur in an elective setting and include a consultant urologist. Conclusion: Pregnancy in women with Fowler's syndrome who have undergone Clam cystoplasty and the Mitrofanoff procedure is rare, and management requires careful planning and a multidisciplinary approach. This case highlights the importance of individualized care plans and close monitoring of both mother and fetus. The patient's risk of recurrent UTIs, coupled with her diabetes and high BMI, necessitated coordinated care across specialties to ensure the best possible outcomes. The Mitrofanoff procedure proved effective in managing her urinary retention, allowing her to maintain self-catheterization during pregnancy. The multidisciplinary team approach was crucial in addressing her complex medical needs, involving obstetrics, urology, and endocrinology. This case adds valuable information to the limited literature on pregnancy management in patients with Fowler's syndrome who have undergone the Mitrofanoff procedure, highlighting the need for comprehensive, individualized care and the involvement of a multidisciplinary team to achieve the best results.

Keywords: fowler's syndrome, clam cystoplasty, mitrofanoff procedure, pregnancy

Procedia PDF Downloads 22
460 The Implication of Augmentation Cystoplasty with Mitrofanoff Channel on Reproduction Age Group and Outcome of Pregnancy

Authors: Amal A. Qedrah, Sofia A. Malik, Madiha Akbar

Abstract:

The aim of this article is to share a rare clinical case of pregnancy and surgical delivery in a patient who has undergone augmentation cystoplasty with mitrofanoff channel in the past. Methods: This case report is about a woman who conceived naturally at the age of 27, previously underwent augmentation cystoplasty at the age of 10 years with mitrofanoff procedure using self-clean intermittent catheterization. Furthermore, this pregnancy was complicated by the presence of preeclampsia diagnosed at term and PROM. Following the failure of induction for intrapartum preeclampsia, the patient delivered a healthy baby via low transverse cesarean section at 38 weeks done at Latifa Hospital, Dubai. Conclusion: The procedure is done at a pediatric or young age, after which most patients reach reproductive age. There is no contraindication to pregnancy vaginally or surgically; however, this case was complicated by preeclampsia, due to which this patient was taken for a cesarean section. It is advisable to consult a urologist frequently along with taking regular bacteriological urine samples and blood samples with renal ultrasonography for the evaluation of the kidney. Antibacterial treatment or prophylaxis should be used during pregnancy if necessary and intermittent self-catherization is mostly performed routinely. It is also important to have a urologist on standby during the surgery in order to avoid and/or fix any complications that might come forth.

Keywords: augmentation cystoplasty, cesarean section, delivery, mitrofanoff channel

Procedia PDF Downloads 156
459 Controlled Nano Texturing in Silicon Wafer for Excellent Optical and Photovoltaic Properties

Authors: Deb Kumar Shah, M. Shaheer Akhtar, Ha Ryeon Lee, O-Bong Yang, Chong Yeal Kim

Abstract:

The crystalline silicon (Si) solar cells are highly renowned photovoltaic technology and well-established as the commercial solar technology. Most of the solar panels are globally installed with the crystalline Si solar modules. At the present scenario, the major photovoltaic (PV) market is shared by c-Si solar cells, but the cost of c-Si panels are still very high as compared with the other PV technology. In order to reduce the cost of Si solar panels, few necessary steps such as low-cost Si manufacturing, cheap antireflection coating materials, inexpensive solar panel manufacturing are to be considered. It is known that the antireflection (AR) layer in c-Si solar cell is an important component to reduce Fresnel reflection for improving the overall conversion efficiency. Generally, Si wafer exhibits the 30% reflection because it normally poses the two major intrinsic drawbacks such as; the spectral mismatch loss and the high Fresnel reflection loss due to the high contrast of refractive indices between air and silicon wafer. In recent years, researchers and scientists are highly devoted to a lot of researches in the field of searching effective and low-cost AR materials. Silicon nitride (SiNx) is well-known AR materials in commercial c-Si solar cells due to its good deposition and interaction with passivated Si surfaces. However, the deposition of SiNx AR is usually performed by expensive plasma enhanced chemical vapor deposition (PECVD) process which could have several demerits like difficult handling and damaging the Si substrate by plasma when secondary electrons collide with the wafer surface for AR coating. It is very important to explore new, low cost and effective AR deposition process to cut the manufacturing cost of c-Si solar cells. One can also be realized that a nano-texturing process like the growth of nanowires, nanorods, nanopyramids, nanopillars, etc. on Si wafer can provide a low reflection on the surface of Si wafer based solar cells. The above nanostructures might be enhanced the antireflection property which provides the larger surface area and effective light trapping. In this work, we report on the development of crystalline Si solar cells without using the AR layer. The Silicon wafer was modified by growing nanowires like Si nanostructures using the wet controlled etching method and directly used for the fabrication of Si solar cell without AR. The nanostructures over Si wafer were optimized in terms of sizes, lengths, and densities by changing the etching conditions. Well-defined and aligned wires like structures were achieved when the etching time is 20 to 30 min. The prepared Si nanostructured displayed the minimum reflectance ~1.64% at 850 nm with the average reflectance of ~2.25% in the wavelength range from 400-1000 nm. The nanostructured Si wafer based solar cells achieved the comparable power conversion efficiency in comparison with c-Si solar cells with SiNx AR layer. From this study, it is confirmed that the reported method (controlled wet etching) is an easy, facile method for preparation of nanostructured like wires on Si wafer with low reflectance in the whole visible region, which has greater prospects in developing c-Si solar cells without AR layer at low cost.

Keywords: chemical etching, conversion efficiency, silicon nanostructures, silicon solar cells, surface modification

Procedia PDF Downloads 123
458 The Robotic Factor in Left Atrial Myxoma

Authors: Abraham J. Rizkalla, Tristan D. Yan

Abstract:

Atrial myxoma is the most common primary cardiac tumor, and can result in cardiac failure secondary to obstruction, or systemic embolism due to fragmentation. Traditionally, excision of atrial an myxoma has been performed through median sternotomy, however the robotic approach offers several advantages including less pain, improved cosmesis, and faster recovery. Here, we highlight the less well recognized advantages and technical aspects to robotic myxoma resection. This video-presentation demonstrates the resection of a papillary subtype left atrial myxoma using the DaVinci© Xi surgical robot. The 10x magnification and 3D vision allows for the interface between the tumor and the interatrial septum to be accurately dissected, without the need to patch the interatrial septum. Several techniques to avoid tumor fragmentation and embolization are demonstrated throughout the procedure. The tumor was completely excised with clear margins. There was no atrial septal defect or mitral valve injury on post operative transesophageal echocardiography. The patient was discharged home on the fourth post-operative day. This video-presentation highlights the advantages of the robotic approach in atrial myxoma resection compared with sternotomy, as well as emphasizing several technical considerations to avoid potential complications.

Keywords: cardiac surgery, left atrial myxoma, cardiac tumour, robotic resection

Procedia PDF Downloads 68
457 Electron Microscopical Analysis of Arterial Line Filters During Cardiopulmonary Bypass

Authors: Won-Gon Kim

Abstract:

Introduction: The clinical value of arterial line filters is still a controversial issue. Proponents of arterial line filtration argue that filters remove particulate matter and undissolved gas from circulation, while opponents argue the absence of conclusive clinical data. We conducted scanning electron microscope (SEM) studies of arterial line filters used clinically in the CPB circuits during adult cardiac surgery and analyzed the types and characteristics of materials entrapped in the arterial line filters. Material and Methods: Twelve arterial line filters were obtained during routine hypothermic cardiopulmonary bypass in 12 adult cardiac patients. The arterial line filter was a screen type with a pore size of 40 ㎛ (Baxter Health care corporation Bentley division, Irvine, CA, U.S.A.). After opening the housing, the woven polyester strands were examined with SEM. Results and Conclusion: All segments examined(120 segments, each 2.5 X 2.5 cm in size) contained no embolic particles larger in their cross-sectional area than the pore size of the filter(40 ㎛). The origins of embolic particulates were mostly from environmental foreign bodies. This may suggest a possible need for more aggressive filtration of smaller particulates than is generally carried out at the present time.

Keywords: arterial line filter, tubing wear, scanning electron microscopy, SEM

Procedia PDF Downloads 441
456 Systemic Factors, Intraocular Lens, and Ocular Abnormalities in Patients with Intraocular Lens Glistening at a Tertiary Hospital in Semarang

Authors: Azmi Ilmi Aziz, Wisnu Sadasih, Rizal Fanany

Abstract:

Purpose: This study describes systemic factors, intraocular lens (IOL), and ocular abnormalities in patients with IOL glistening at a tertiary hospital in Semarang. Methods: A retrospective, with a descriptive approach on patients with IOL glistening who visited the eye clinic between August 2019 to June 2023. Results: Twenty-five patients were examined; 11 patients (44%) had IOL glistening in their right eye, 4 patients (16%) in their left eye, and 10 patients (40%) in both eyes. The gender of patients consisted of 12 male patients (48%) and 13 female patients (52%). The median age of the patients was 68 years. The mean onset was 4.44 years after the first cataract surgery. Hypertension was found in 13 patients (52%), and diabetes was found in 9 patients (36%). Nine patients (36%) were identified with a foldable IOL with a closed loop design, and 1 patient (4%) with a PMMA IOL with an iris-fixated IOL design, while 15 other patients’ IOL were unrecorded. Glaucoma was found in 3 patients (12%). Conclusions: The result of this study showed that more than half of the patients were hypertensive, and some were glaucomatous, which had been discussed relevant in previous studies. Most IOL that could be identified was foldable IOL with a closed loop design. To our knowledge, the design of an IOL to glistening had never been explored. A longer study involving larger subjects is needed to better describe the systemic factors, IOL, and ocular abnormalities in patients with IOL glistening.

Keywords: glistening, intraocular lens, foldable IOL, PMMA IOL

Procedia PDF Downloads 82