Search results for: leaflet valve
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 234

Search results for: leaflet valve

114 Sterols Regulate the Activity of Phospholipid Scramblase by Interacting through Putative Cholesterol Binding Motif

Authors: Muhasin Koyiloth, Sathyanarayana N. Gummadi

Abstract:

Biological membranes are ordered association of lipids, proteins, and carbohydrates. Lipids except sterols possess asymmetric distribution across the bilayer. Eukaryotic membranes possess a group of lipid translocators called scramblases that disrupt phospholipid asymmetry. Their action is implicated in cell activation during wound healing and phagocytic clearance of apoptotic cells. Cholesterol is one of the major membrane lipids distributed evenly on both the leaflet and can directly influence the membrane fluidity through the ordering effect. The fluidity has an impact on the activity of several membrane proteins. The palmitoylated phospholipid scramblases localized to the lipid raft which is characterized by a higher number of sterols. Here we propose that cholesterol can interact with scramblases through putative CRAC motif and can modulate their activity. To prove this, we reconstituted phospholipid scramblase 1 of C. elegans (SCRM-1) in proteoliposomes containing different amounts of cholesterol (Liquid ordered/Lo). We noted that the presence of cholesterol reduced the scramblase activity of wild-type SCRM-1. The interaction between SCRM-1 and cholesterol was confirmed by fluorescence spectroscopy using NBD-Chol. Also, we observed loss of such interaction when one of I273 in the CRAC motif mutated to Asp. Interestingly, the point mutant has partially retained scramblase activity in Lo vesicles. The current study elucidated the important interaction between cholesterol and SCRM-1 to fine-tune its activity in artificial membranes.

Keywords: artificial membranes, CRAC motif, plasma membrane, PL scramblase

Procedia PDF Downloads 158
113 Performance Analysis of Vapour Compression Refrigeration System with Alternate Refrigerants

Authors: K. Parthiban, P. Pradeep, I. Pon Surya Prakash, S. Vinoth, A. Murugan

Abstract:

The main aim of this project is to analyze the performance of vapor compression refrigeration system with alternate refrigerants. Currently we are using R134a as refrigerant. It is used in both household and industrial appliances as refrigerant. It has an advantage that the ozone depletion potential is zero i.e. R134a does not affects ozone layer. But its Global warming potential is considerably high. Also the compressor failure occurs frequently. Hence this project deals with how the performance of R134a varies with blended refrigerants such as R416a and R407c. This analysis is based on how much the Co-efficient of Performance (COP) varies with different refrigerants.

Keywords: compressor, condenser, expansion valve, evaporator

Procedia PDF Downloads 299
112 Closed Mitral Valvotomy: A Safe and Promising Procedure

Authors: Sushil Kumar Singh, Kumar Rahul, Vivek Tewarson, Sarvesh Kumar, Shobhit Kumar

Abstract:

Objective: Rheumatic mitral stenosis continues to be a major public health problem in developing countries. When the left atrium (LA) is unable to fill the left ventricle (LV) at normal LA pressures due to impaired relaxation and impaired compliance, diastolic dysfunction occurs. The assessment of left ventricular (LV) diastolic function and filling pressures is of clinical importance to identify underlying cardiac disease, its treatment, and to assess prognosis. 2D echocardiography can detect diastolic dysfunction with excellent sensitivity and minimal risk when compared to the gold standard of invasive pressure-volume measurements. Material and Method: This was a one-year study consisting of twenty-nine patients of isolated rheumatic severe mitral stenosis. Data was analyzed preoperative and post operative (at one month follow-up). Transthoracic 2D echocardiographic parameters of the diastolic function are transmitral flow, pulmonary venous flow, mitral annular tissue doppler, and color M-mode doppler. In our study, mitral valve orifice area, ejection fraction, deceleration time, E/A-wave, E/E’-wave, myocardial performance index of left ventricle (Tei index ), and Mitral inflow propagation velocity were included for echocardiographic evaluation. The statistical analysis was performed on SPSS Version 15.0 statistical analysis software. Result: Twenty-nine patients underwent successful closed mitral commissurotomy for isolated mitral stenosis. The outcome measures were observed pre-operatively and at one-month follow-up. The majority of patients were in NYHA grade III (69.0%) in the preoperative period, which improved to NYHA grade I (48.3%) after closed mitral commissurotomy. Post-surgery mitral valve area increased from 0.77 ± 0.13 to 2.32 ± 0.26 cm, ejection fraction increased from 61.38 ± 4.61 to 64.79 ± 3.22. There was a decrease in deceleration time from 231.55 ± 49.31 to 168.28 ± 14.30 ms, E/A ratio from 1.70 ± 0.54 from 0.89 ± 0.39, E/E’ ratio from 14.59 ± 3.34 to 8.86 ± 3.03. In addition, there was improvement in TIE index from 0.50 ± 0.03 to 0.39 ± 0.06 and mitral inflow propagation velocity from 47.28 ± 3.71 to 57.86 ± 3.19 cm/sec. In peri-operative and follow-up, there was no incidence of severe mitral regurgitation (MR). There was no thromboembolic incident and no mortality.

Keywords: closed mitral valvotomy, mitral stenosis, open mitral commissurotomy, balloon mitral valvotomy

Procedia PDF Downloads 57
111 Modern Cardiac Surgical Outcomes in Nonagenarians: A Multicentre Retrospective Observational Study

Authors: Laurence Weinberg, Dominic Walpole, Dong-Kyu Lee, Michael D’Silva, Jian W. Chan, Lachlan F. Miles, Bradley Carp, Adam Wells, Tuck S. Ngun, Siven Seevanayagam, George Matalanis, Ziauddin Ansari, Rinaldo Bellomo, Michael Yii

Abstract:

Background: There have been multiple recent advancements in the selection, optimization and management of cardiac surgical patients. However, there is limited data regarding the outcomes of nonagenarians undergoing cardiac surgery, despite this vulnerable cohort increasingly receiving these interventions. This study describes the patient characteristics, management and outcomes of a group of nonagenarians undergoing cardiac surgery in the context of contemporary peri-operative care. Methods: A retrospective observational study was conducted of patients 90 to 99 years of age (i.e., nonagenarians) who had undergone cardiac surgery requiring a classic median sternotomy (i.e., open-heart surgery). All operative indications were included. Patients who underwent minimally invasive surgery, transcatheter aortic valve implantation and thoracic aorta surgery were excluded. Data were collected from four hospitals in Victoria, Australia, over an 8-year period (January 2012 – December 2019). The primary objective was to assess six-month mortality in nonagenarians undergoing open-heart surgery and to evaluate the incidence and severity of postoperative complications using the Clavien-Dindo classification system. The secondary objective was to provide a detailed description of the characteristics and peri-operative management of this group. Results: A total of 12,358 adult patients underwent cardiac surgery at the study centers during the observation period, of whom 18 nonagenarians (0.15%) fulfilled the inclusion criteria. The median (IQR) [min-max] age was 91 years (90.0:91.8) [90-94] and 14 patients (78%) were men. Cardiovascular comorbidities, polypharmacy and frailty, were common. The median (IQR) predicted in-hospital mortality by EuroSCORE II was 6.1% (4.1-14.5). All patients were optimized preoperatively by a multidisciplinary team of surgeons, cardiologists, geriatricians and anesthetists. All index surgeries were performed on cardiopulmonary bypass. Isolated coronary artery bypass grafting (CABG) and CABG with aortic valve replacement were the most common surgeries being performed in four and five patients, respectively. Half the study group underwent surgery involving two or more major procedures (e.g. CABG and valve replacement). Surgery was undertaken emergently in 44% of patients. All patients except one experienced at least one postoperative complication. The most common complications were acute kidney injury (72%), new atrial fibrillation (44%) and delirium (39%). The highest Clavien-Dindo complication grade was IIIb occurring once each in three patients. Clavien-Dindo grade IIIa complications occurred in only one patient. The median (IQR) postoperative length of stay was 11.6 days (9.8:17.6). One patient was discharged home and all others to an inpatient rehabilitation facility. Three patients had an unplanned readmission within 30 days of discharge. All patients had follow-up to at least six months after surgery and mortality over this period was zero. The median (IQR) duration of follow-up was 11.3 months (6.0:26.4) and there were no cases of mortality observed within the available follow-up records. Conclusion: In this group of nonagenarians undergoing cardiac surgery, postoperative six-month mortality was zero. Complications were common but generally of low severity. These findings support carefully selected nonagenarian patients being offered cardiac surgery in the context of contemporary, multidisciplinary perioperative care. Further, studies are needed to assess longer-term mortality and functional and quality of life outcomes in this vulnerable surgical cohort.

Keywords: cardiac surgery, mortality, nonagenarians, postoperative complications

Procedia PDF Downloads 93
110 Compressed Natural Gas (CNG) Injector Research for Dual Fuel Engine

Authors: Adam Majczak, Grzegorz Barański, Marcin Szlachetka

Abstract:

Environmental considerations necessitate the search for new energy sources. One of the available solutions is a partial replacement of diesel fuel by compressed natural gas (CNG) in the compression ignition engines. This type of the engines is used mainly in vans and trucks. These units are also gaining more and more popularity in the passenger car market. In Europe, this part of the market share reaches 50%. Diesel engines are also used in industry in such vehicles as ship or locomotives. Diesel engines have higher emissions of nitrogen oxides in comparison to spark ignition engines. This can be currently limited by optimizing the combustion process and the use of additional systems such as exhaust gas recirculation or AdBlue technology. As a result of the combustion process of diesel fuel also particulate matter (PM) that are harmful to the human health are emitted. Their emission is limited by the use of a particulate filter. One of the method for toxic components emission reduction may be the use of liquid gas fuel such as propane and butane (LPG) or compressed natural gas (CNG). In addition to the environmental aspects, there are also economic reasons for the use of gaseous fuels to power diesel engines. A total or partial replacement of diesel gas is possible. Depending on the used technology and the percentage of diesel fuel replacement, it is possible to reduce the content of nitrogen oxides in the exhaust gas even by 30%, particulate matter (PM) by 95 % carbon monoxide and by 20%, in relation to original diesel fuel. The research object is prototype gas injector designed for direct injection of compressed natural gas (CNG) in compression ignition engines. The construction of the injector allows for it positioning in the glow plug socket, so that the gas is injected directly into the combustion chamber. The cycle analysis of the four-cylinder Andoria ADCR engine with a capacity of 2.6 dm3 for different crankshaft rotational speeds allowed to determine the necessary time for fuel injection. Because of that, it was possible to determine the required mass flow rate of the injector, for replacing as much of the original fuel by gaseous fuel. To ensure a high value of flow inside the injector, supply pressure equal to 1 MPa was applied. High gas supply pressure requires high value of valve opening forces. For this purpose, an injector with hydraulic control system, using a liquid under pressure for the opening process was designed. On the basis of air pressure measurements in the flow line after the injector, the analysis of opening and closing of the valve was made. Measurements of outflow mass of the injector were also carried out. The results showed that the designed injector meets the requirements necessary to supply ADCR engine by the CNG fuel.

Keywords: CNG, diesel engine, gas flow, gas injector

Procedia PDF Downloads 467
109 Sterilization Effects of Low Concentration of Hydrogen Peroxide Solution on 3D Printed Biodegradable Polyurethane Nanocomposite Scaffold for Heart Valve Regeneration

Authors: S. E. Mohmad-Saberi, W. Song, N. Oliver, M. Adrian, T.C. Hsu, A. Darbyshire

Abstract:

Biodegradable polyurethane (PU) has emerged as a potential material to promote repair and regeneration of damaged/diseased tissues in heart valve regeneration due to its excellent biomechanical profile. Understanding the effects of sterilization on their properties is vital since they are more sensitive and more critical of porous structures compared to bulk ones. In this study, the effects of low concentration of hydrogen peroxide (H₂O₂) solution sterilization has been investigated to determine whether the procedure would be efficient and non-destructive to porous three-dimensional (3D) elastomeric nanocomposite, polyhedral oligomeric silsesquioxane-terminated poly (ethylene-diethylene glycol succinate-sebacate) urea-urethane (POSS-EDSS-PU) scaffold. All the samples were tested for sterility following sterilization using phosphate buffer saline (PBS) as control and 5 % v/v H₂O₂ solution. The samples were incubated in tryptic soy broth for the cultivation of microorganisms under agitation at 37˚C for 72 hours. The effects of the 5 % v/v H₂O₂ solution sterilization were evaluated in terms of morphology, chemical and mechanical properties using scanning electron microscopy (SEM), Fourier transform infrared (FTIR) and tensile tester apparatus. Toxicity effects of the 5 % v/v H₂O₂ solution decontamination were studied by in vitro cytotoxicity test, where the cellular responses of human dermal fibroblast (HDF) were examined. A clear, uncontaminated broth using 5 % v/v H₂O₂ solution method indicated efficient sterilization after 3 days, while the non-sterilized control shows clouding broth indicated contamination. The morphology of 3D POSS-EDSS-PU scaffold appeared to have similar morphology after sterilization with 5 % v/v H₂O₂ solution regarding of pore size and surface. FTIR results show that the sterilized samples and non-sterilized control share the same spectra pattern, confirming no significant alterations over the surface chemistry. For the mechanical properties of the H₂O₂ solution-treated scaffolds, the tensile strain was not significantly decreased, however, become significantly stiffer after the sterilization. No cytotoxic effects were observed after the 5 % v/v H₂O₂ solution sterilization as confirmed by cell viability assessed by Alamar Blue assay. The results suggest that low concentration of 5 % v/v hydrogen peroxide solution can be used as an alternative method for sterilizing biodegradable 3D porous scaffold with micro/nano-architecture without structural deformation. This study provides the understanding of the sterilization effects on biomechanical profile and cell proliferation of 3D POSS-EDSS-PU scaffolds.

Keywords: biodegradable, hydrogen peroxide solution, POSS-EDSS-PU, sterilization

Procedia PDF Downloads 139
108 Design Development and Qualification of a Magnetically Levitated Blower for C0₂ Scrubbing in Manned Space Missions

Authors: Larry Hawkins, Scott K. Sakakura, Michael J. Salopek

Abstract:

The Marshall Space Flight Center is designing and building a next-generation CO₂ removal system, the Four Bed Carbon Dioxide Scrubber (4BCO₂), which will use the International Space Station (ISS) as a testbed. The current ISS CO2 removal system has faced many challenges in both performance and reliability. Given that CO2 removal is an integral Environmental Control and Life Support System (ECLSS) subsystem, the 4BCO2 Scrubber has been designed to eliminate the shortfalls identified in the current ISS system. One of the key required upgrades was to improve the performance and reliability of the blower that provides the airflow through the CO₂ sorbent beds. A magnetically levitated blower, capable of higher airflow and pressure than the previous system, was developed to meet this need. The design and qualification testing of this next-generation blower are described here. The new blower features a high-efficiency permanent magnet motor, a five-axis, active magnetic bearing system, and a compact controller containing both a variable speed drive and a magnetic bearing controller. The blower uses a centrifugal impeller to pull air from the inlet port and drive it through an annular space around the motor and magnetic bearing components to the exhaust port. Technical challenges of the blower and controller development include survival of the blower system under launch random vibration loads, operation in microgravity, packaging under strict size and weight requirements, and successful operation during 4BCO₂ operational changeovers. An ANSYS structural dynamic model of the controller was used to predict response to the NASA defined random vibration spectrum and drive minor design changes. The simulation results are compared to measurements from qualification testing the controller on a vibration table. Predicted blower performance is compared to flow loop testing measurements. Dynamic response of the system to valve changeovers is presented and discussed using high bandwidth measurements from dynamic pressure probes, magnetic bearing position sensors, and actuator coil currents. The results presented in the paper show that the blower controller will survive launch vibration levels, the blower flow meets the requirements, and the magnetic bearings have adequate load capacity and control bandwidth to maintain the desired rotor position during the valve changeover transients.

Keywords: blower, carbon dioxide removal, environmental control and life support system, magnetic bearing, permanent magnet motor, validation testing, vibration

Procedia PDF Downloads 107
107 Numerical Simulation and Experimental Validation of the Hydraulic L-Shaped Check Ball Behavior

Authors: Shinji Kajiwara

Abstract:

The spring-driven ball-type check valve is one of the most important components of hydraulic systems: it controls the position of the ball and prevents backward flow. To simplify the structure, the spring must be eliminated, and to accomplish this, the flow pattern and the behavior of the check ball in L-shaped pipe must be determined. In this paper, we present a full-scale model of a check ball made of acrylic resin, and we determine the relationship between the initial position of the ball, the position and diameter of the inflow port. The check flow rate increases in a standard center inflow model, and it is possible to greatly decrease the check-flow rate by shifting the inflow from the center.

Keywords: hydraulics, pipe flow, numerical simulation, flow visualization, check ball, L-shaped pipe

Procedia PDF Downloads 273
106 Design and Evaluation of a Pneumatic Muscle Actuated Gripper

Authors: Tudor Deaconescu, Andrea Deaconescu

Abstract:

Deployment of pneumatic muscles in various industrial applications is still in its early days, considering the relative newness of these components. The field of robotics holds particular future potential for pneumatic muscles, especially in view of their specific behaviour known as compliance. The paper presents and discusses an innovative constructive solution for a gripper system mountable on an industrial robot, based on actuation by a linear pneumatic muscle and transmission of motion by gear and rack mechanism. The structural, operational and constructive models of the new gripper are presented, along with some of the experimental results obtained subsequently to the testing of a prototype. Further presented are two control variants of the gripper system, one by means of a 3/2-way fast-switching solenoid valve, the other by means of a proportional pressure regulator. Advantages and disadvantages are discussed for both variants.

Keywords: gripper system, pneumatic muscle, structural modelling, robotics

Procedia PDF Downloads 214
105 Skid-mounted Gathering System Hydrate Control And Process Simulation Optimization

Authors: Di Han, Lingfeng Li, Peixue Zhang, Yuzhuo Zhang

Abstract:

Since natural gas extracted from the wellhead of a gas well, after passing through the throttle valve, causes a rapid decrease in temperature along with a decrease in pressure, which creates conditions for hydrate generation. In order to solve the problem of hydrate generation in the process of wellhead gathering, effective measures should be taken to prevent hydrate generation. In this paper, we firstly introduce the principle of natural gas throttling temperature drop and the theoretical basis of hydrate inhibitor injection calculation, and then use HYSYS software to simulate and calculate the three processes and determine the key process parameters. The hydrate control process applicable to the skid design of natural gas wellhead gathering skids was determined by comparing the hydrate control effect, energy consumption of key equipment and process adaptability.

Keywords: natural gas, hydrate control, skid design, HYSYS

Procedia PDF Downloads 58
104 Combustion Characteristics of Bioethanol-Biodiesel-Diesel Fuel Blends Used in a Common Rail Diesel Engine

Authors: Hasan Aydogan

Abstract:

The changes in the performance, emission and combustion characteristics of bioethanol-safflower biodiesel and diesel fuel blends used in a common rail diesel engine were investigated in this experimental study. E20B20D60 (20% bioethanol, 20% biodiesel, 60% diesel fuel by volume), E30B20D50, E50B20D30 and diesel fuel (D) were used as fuel. The tests were performed at full throttle valve opening and variable engine speeds. The results of the tests showed decreases in engine power, engine torque, carbon monoxide (CO), hydrocarbon (HC) and smoke density values with the use of bioethanol-biodiesel and diesel fuel blends, whereas, increases were observed in nitrogen oxide (NOx) and brake specific fuel consumption (BSFC) values. When combustion characteristics were examined, it was seen that the values were close to one another.

Keywords: bioethanol, biodiesel, safflower, combustion characteristics

Procedia PDF Downloads 499
103 Nonlinear Adaptive PID Control for a Semi-Batch Reactor Based on an RBF Network

Authors: Magdi. M. Nabi, Ding-Li Yu

Abstract:

Control of a semi-batch polymerization reactor using an adaptive radial basis function (RBF) neural network method is investigated in this paper. A neural network inverse model is used to estimate the valve position of the reactor; this method can identify the controlled system with the RBF neural network identifier. The weights of the adaptive PID controller are timely adjusted based on the identification of the plant and self-learning capability of RBFNN. A PID controller is used in the feedback control to regulate the actual temperature by compensating the neural network inverse model output. Simulation results show that the proposed control has strong adaptability, robustness and satisfactory control performance and the nonlinear system is achieved.

Keywords: Chylla-Haase polymerization reactor, RBF neural networks, feed-forward, feedback control

Procedia PDF Downloads 677
102 A Prospective Study on the Evaluation of Statins Usage on HbA1c Control among Type 2 Diabetes Mellitus in an Outpatients Setting

Authors: Mohamed A. Hammad, Dzul Azri Mohamed Noor, Syed Azhar Syed Sulaiman, Abeer Kharshid, Nor Azizah Aziz, Tarek M. Elsayed

Abstract:

Medication safety is always an issue. In 2015, the National Pharmaceutical Control Bureau released a statement requesting all statins manufacturers in Malaysia to include the risk of diabetes information in the drug information leaflet in response to United States Food and Drug Administration (U.S. FDA) report. However, the data regarding this warning label in Malaysia is limited, so there is still some uncertainty whether such risk can also be observed in the Malaysian population or not. The study aims to determine the effect of statins on HbA1c% in type 2 diabetic outpatients in endocrine clinics at Hospital Pulau Pinang between June 2015 and May 2016 in Malaysia. In a prospective cohort study, records of 400 type 2 diabetic patients (control group 104 patients not using statin and treatment group 296 patients using statin) were reviewed to identify demographic criteria and lab tests. The prevalence of glycemic control (Glycated hemoglobin, HbA1C ≤ 7% for patient < 65 years, and < 8% for patient ≥ 65 years) was estimated, according to American Diabetes Association guidelines 2015. The results were presented as descriptive statistics. From 296 patients with Type 2 diabetes using statins cohort with a mean age of 57.52 ± 12.2 years, only 81 (27.4%) cases had controlled glycemia, and 215 (72.6%) had uncontrolled glycemia, CI: 95% (6.3–11.1). While the control group 104 diabetic patients had a mean age 46.1 ± 18 years and distributed among 59 (56.7%) patients with controlled diabetes and 45 (43.3%) cases, had uncontrolled glycemia, CI: 95% (5.2–10.3). The relative risk (RR) of uncontrolled glycemia in diabetic patients used statins was 1.68, and the excessive relative risk (ERR) was 68%. The absolute risk (AR) was 29.3%, and the number needed to harm (NNH) was 4. Diabetic patients using statins have more risk of uncontrolled glycemia than the patients with Type 2 diabetes non-using statins.

Keywords: diabetes mellitus, HbA1c, Malaysia, outpatients, statin, type 2, uncontrolled glycemia

Procedia PDF Downloads 257
101 Service Evaluation of Consent for Hand and Wrist Surgery and Formulation of Evidence-Based Guidelines

Authors: Parsa Keyvani, Alistair Phillips, David Warwick

Abstract:

Background: The current process for gaining patient consent for hand and wrist surgery at University Hospital Southampton (UHS) is paper-based and makes use of generic forms provided by the NHS and no patient information leaflet is available relating to hand and wrist surgery. Aims: To evaluate the process of obtaining clinical consent and suggest ways in which the service can be improved. Methods: A log-book review of four orthopaedic surgeons at UHS was carried out over a three-month period in order to identify the 10 most common types of elective hand and wrist surgeries performed. A literature review was carried out to identify the complications of these surgeries. The surgeries were then divided into 6 types: nerve, bone, ligament, joint, tendon and dupuytren’s surgery. A digitised consent form was created covering the complications of all 6 surgery types. Finally, the surgeons at the orthopaedic department of UHS were asked whether they prefer the old paper-based or the digitised consent form. Results: All of the surgeons felt that the procedure type-based form was easier to read, use and understand. Conclusion: This research highlights a number of problems related to the use of current NHS consent forms. The proposed solution is to use a set of digitised, procedure type-based consent forms. Digital consent forms can be filled in in advance and sent to the patient electronically along with any relevant information leaflets, thus giving them time to absorb the information and come up with any questions before they have their pre-procedure discussion with their doctor. This would allow the doctor to focus the consultation on the patient rather than writing out the consent form and would ultimately be a step forward in making the NHS a global digital leader and fully embrace the opportunity offered by technology.

Keywords: digitised consent form, elective surgery, hand surgery complications, informed consent, procedure type-based consent form

Procedia PDF Downloads 67
100 Utilizing Quantum Chemistry for Nanotechnology: Electron and Spin Movement in Molecular Devices

Authors: Mahsa Fathollahzadeh

Abstract:

The quick advancement of nanotechnology necessitates the creation of innovative theoretical approaches to elucidate complex experimental findings and forecast novel capabilities of nanodevices. Therefore, over the past ten years, a difficult task in quantum chemistry has been comprehending electron and spin transport in molecular devices. This thorough evaluation presents a comprehensive overview of current research and its status in the field of molecular electronics, emphasizing the theoretical applications to various device types and including a brief introduction to theoretical methods and their practical implementation plan. The subject matter includes a variety of molecular mechanisms like molecular cables, diodes, transistors, electrical and visual switches, nano detectors, magnetic valve gadgets, inverse electrical resistance gadgets, and electron tunneling exploration. The text discusses both the constraints of the method presented and the potential strategies to address them, with a total of 183 references.

Keywords: chemistry, nanotechnology, quantum, molecule, spin

Procedia PDF Downloads 15
99 Evaluation of Cryoablation Procedures in Treatment of Atrial Fibrillation from 3 Years' Experiences in a Single Heart Center

Authors: J. Yan, B. Pieper, B. Bucsky, B. Nasseri, S. Klotz, H. H. Sievers, S. Mohamed

Abstract:

Cryoablation is evermore applied for interventional treatment of paroxysmal (PAAF) or persistent atrial fibrillation (PEAF). In the cardiac surgery, this procedure is often combined with coronary arterial bypass graft (CABG) and valve operations. Three different methods are feasible in this sense in respect to practicing extents and mechanisms such as lone left atrial cryoablation, Cox-Maze IV and III in our heart center. 415 patients (68 ± 0.8ys, male 68.2%) with predisposed atrial fibrillation who initially required either coronary or valve operations were enrolled and divided into 3 matched groups according to deployed procedures: CryoLA-group (cryoablation of lone left atrium, n=94); Cox-Maze-IV-group (n=93) and Cox-Maze-III-group (n=8). All patients additionally received closure of the left atrial appendage (LAA) and regularly underwent three-year ambulant follow-up assessments (3, 6, 9, 12, 18, 24, 30 and 36 months). Burdens of atrial fibrillation were assessed directly by means of cardiac monitor (Reveal XT, Medtronic) or of 3-day Holter electrocardiogram. Herewith, attacks frequencies of AF and their circadian patterns were systemically analyzed. Furthermore, anticoagulants and regular rate-/rhythm-controlling medications were evaluated and listed in terms of anti-rate and anti-rhythm regimens. Concerning PAAF treatment, Cox Maze IV procedure provided therapeutically acceptable effect as lone left atrium (LA) cryoablation did (5.25 ± 5.25% vs. 10.39 ± 9.96% AF-burden, p > 0.05). Interestingly, Cox Maze III method presented a better short-term effect in the PEAF therapy in comparison to lone cryoablation of LA and Cox Maze IV (0.25 ± 0.23% vs. 15.31 ± 5.99% and 9.10 ± 3.73% AF-burden within the first year, p < 0.05). But this therapeutic advantage went lost during ongoing follow-ups (26.65 ± 24.50% vs. 8.33 ± 8.06% and 15.73 ± 5.88% in 3rd follow-up year). In this way, lone LA-cryoablation established its antiarrhythmic efficacy and 69.5% patients were released from the Vit-K-antagonists, while Cox Maze IV liberated 67.2% patients from continuous anticoagulant medication. The AF-recurrences mostly performed such attacks property as less than 60min duration for all 3 procedures (p > 0.05). In the sense of the circadian distribution of the recurrence attacks, weighted by ongoing follow-ups, lone LA cryoablation achieved and stabilized the antiarrhythmic effects over time, which was especially observed in the treatment of PEAF, while Cox Maze IV and III had their antiarrhythmic effects weakened progressively. This phenomenon was likewise evaluable in the therapy of circadian rhythm of reverting AF-attacks. Furthermore, the strategy of rate control was much more often applied to support and maintain therapeutic successes obtained than the one of rhythm control. Derived from experiences in our heart center, lone LA cryoablation presented equivalent effects in the treatment of AF in comparison to Cox Maze IV and III procedures. These therapeutic successes were especially investigable in the patients suffering from persistent AF (PEAF). Additional supportive strategies such as rate control regime should be initialized and implemented to improve the therapeutic effects of the cryoablations according to appropriate criteria.

Keywords: AF-burden, atrial fibrillation, cardiac monitor, COX MAZE, cryoablation, Holter, LAA

Procedia PDF Downloads 174
98 Design and Development of Hybrid Rocket Motor

Authors: Aniket Aaba Kadam, Manish Mangesh Panchal, Roushan Ashit Sharma

Abstract:

This project focuses on the design and development of a lab-scale hybrid rocket motor to accurately determine the regression rate of a fuel/oxidizer combination consisting of solid paraffin and gaseous oxygen (GOX). Hybrid motors offer the advantage of on-demand thrust control over both solid and liquid systems in certain applications. The thermodynamic properties of the propellant combination were calculated using NASA CEA at different chamber pressures and corresponding O/F values to determine initial operating conditions with suitable peak temperatures and optimal O/F values. The project also includes the design of the injector orifice and the determination of the final design configurations of the motor casing, pressure control setup, and valve configuration. This research will be valuable in advancing the understanding of paraffin-based propulsion and improving the performance of hybrid rocket motors.

Keywords: hybrid rocket, NASA CEA, injector, thrust control

Procedia PDF Downloads 69
97 Effect of Heat Treatment on the Corrosion Behavior of Stainless Steel

Authors: Altoumi Alndalusi

Abstract:

The work examines the aqueous corrosion behavior of grades of stain less steel which are used as corrosion resistant castings for applications such as valve and pump bodies. The corrosion behavior of steels in the as-cast condition has been examined using potentiostatic studies to illustrate the need for correct thermal treatment. A metallurgical examination and chemical analysis were carried out to establish the morphology of the steel structure. Heat treatment was carried out in order to compare damage in relation to microstructure. Optical and scanning electron microscopy examinations confirmed that the austenitic steels suffers from severe localized inter-dendritic pitting attack, while non homogenized castings highly alloyed duplex steels gave inferior corrosion resistance. Through the heat treatment conditions a significant of phase transformation of the duplex steel C were occurred (from ferrite to austenite and sigma plus carbides) and were gave reduction resistance.

Keywords: cast, corrosion, duplex stainless, heat treatment, material, steel

Procedia PDF Downloads 155
96 Pattern of Valvular Involvement and Demographic Features of Patients on Benzathine Penicillin at Dhulikhel Hospital

Authors: Sanjaya Humagain, Rajendra Koju

Abstract:

Background: Rheumatic heart disease (RHD) is the most common cardiovascular disease in children and young adults. Though declined and almost non-existent in developed nations, RHD is still one of the leading cause for premature death and disability in developing countries. Prevalence of RHD is high in both rural as well as urban area of Nepal. Present study is designed to look at the pattern of valvular involvement and demographic features in RHD. Methods: 326 patients indicated for inj. Benzathine penicillin were selected and echocardiograph performed to see the pattern of vavular involvement. Data analysis was done using SPSS 17. Result: The most common type of lesion was mixed type with mitral valve involvement. MR was the most common isolated lesion. MS was more commonly seen in females whereas AS was more common in males. Secondary prophylaxis was more common than primary prophylaxis. Conclusion: RHD still being a major problem and a preventable disease so extensive screening program is required to identify them early and prevent the complication.

Keywords: acute rheumatic fever, RHD, MS, MR, AS, AR, Inj benzathine penicillin

Procedia PDF Downloads 291
95 Right Atrial Tissue Morphology in Acquired Heart Diseases

Authors: Edite Kulmane, Mara Pilmane, Romans Lacis

Abstract:

Introduction: Acquired heart diseases remain one of the leading health care problems in the world. Changes in myocardium of the diseased hearts are complex and pathogenesis is still not fully clear. The aim of this study was to identify appearance and distribution of apoptosis, homeostasis regulating factors, and innervation and ischemia markers in right atrial tissue in different acquired heart diseases. Methods: During elective open heart surgery were taken right atrial tissue fragments from 12 patients. All patients were operated because of acquired heart diseases- aortic valve stenosis (5 patients), coronary heart disease (5 patients), coronary heart disease and secondary mitral insufficiency (1 patient) and mitral disease (1 patient). The mean age was (mean±SD) 70,2±7,0 years (range 58-83 years). The tissues were stained with haematoxylin and eosin methods for routine light-microscopical examination and for immunohistochemical detection of protein gene peptide 9.5 (PGP 9.5), human atrial natriuretic peptide (hANUP), vascular endothelial growth factor (VEGF), chromogranin A and endothelin. Apoptosis was detected by TUNEL method. Results: All specimens showed degeneration of cardiomyocytes with lysis of myofibrils, diffuse vacuolization especially in perinuclear region, different size of cells and their nuclei. The severe invasion of connective tissue was observed in main part of all fragments. The apoptotic index ranged from 24 to 91%. One specimen showed region of newly performed microvessels with cube shaped endotheliocytes that were positive for PGP 9.5, endothelin, chromogranin A and VEGF. From all fragments, taken from patients with coronary heart disease, there were observed numerous PGP 9.5-containing nerve fibres, except in patient with secondary mitral insufficiency, who showed just few PGP 9.5 positive nerves. In majority of specimens there were regions observed with cube shaped mixed -VEGF immunoreactive endocardial and epicardial cells. Only VEGF positive endothelial cells were observed just in few specimens. There was no significant difference of hANUP secreting cells among all specimens. All patients operated due to the coronary heart disease moderate to numerous number of chromogranin A positive cells were seen while in patients with aortic valve stenosis tissue demonstrated just few factor positive cells. Conclusions: Complex detection of different factors may indicate selectively disordered morphopathogenetical event of heart disease: decrease of PGP 9.5 nerves suggests the decreased innervation of organ; increased apoptosis indicates the cell death without ingrowth of connective tissue; persistent presence of hANUP proves the unchanged homeostasis of cardiomyocytes probably supported by expression of chromogranins. Finally, decrease of VEGF detects the regions of affected blood vessels in heart affected by acquired heart disease.

Keywords: heart, apoptosis, protein-gene peptide 9.5, atrial natriuretic peptide, vascular endothelial growth factor, chromogranin A, endothelin

Procedia PDF Downloads 270
94 Optimal Dynamic Economic Load Dispatch Using Artificial Immune System

Authors: I. A. Farhat

Abstract:

The dynamic economic dispatch (DED) problem is one of the complex, constrained optimization problems that have nonlinear, con-convex and non-smooth objective functions. The purpose of the DED is to determine the optimal economic operation of the committed units while meeting the load demand. Associated to this constrained problem there exist highly nonlinear and non-convex practical constraints to be satisfied. Therefore, classical and derivative-based methods are likely not to converge to an optimal or near optimal solution to such a dynamic and large-scale problem. In this paper, an Artificial Immune System technique (AIS) is implemented and applied to solve the DED problem considering the transmission power losses and the valve-point effects in addition to the other operational constraints. To demonstrate the effectiveness of the proposed technique, two case studies are considered. The results obtained using the AIS are compared to those obtained by other methods reported in the literature and found better.

Keywords: artificial immune system, dynamic economic dispatch, optimal economic operation, large-scale problem

Procedia PDF Downloads 214
93 Oil Producing Wells Using a Technique of Gas Lift on Prosper Software

Authors: Nikhil Yadav, Shubham Verma

Abstract:

Gas lift is a common technique used to optimize oil production in wells. Prosper software is a powerful tool for modeling and optimizing gas lift systems in oil wells. This review paper examines the effectiveness of Prosper software in optimizing gas lift systems in oil-producing wells. The literature review identified several studies that demonstrated the use of Prosper software to adjust injection rate, depth, and valve characteristics to optimize gas lift system performance. The results showed that Prosper software can significantly improve production rates and reduce operating costs in oil-producing wells. However, the accuracy of the model depends on the accuracy of the input data, and the cost of Prosper software can be high. Therefore, further research is needed to improve the accuracy of the model and evaluate the cost-effectiveness of using Prosper software in gas lift system optimization

Keywords: gas lift, prosper software, injection rate, operating costs, oil-producing wells

Procedia PDF Downloads 52
92 Surface Adjustments for Endothelialization of Decellularized Porcine Pericardium

Authors: M. Markova, E. Filova, O. Kaplan, R. Matejka, L. Bacakova

Abstract:

The porcine pericardium is used as a material for cardiac and aortic valves substitutes. Current biological aortic heart valve prosthesis have a limited lifetime period because they undergo degeneration. In order to make them more biocompatible and prolong their lifetime it is necessary to reseed the decellularized prostheses with endothelial cells and with valve interstitial cells. The endothelialization of the prosthesis-surface may be supported by suitable chemical surface modification of the prosthesis. The aim of this study is to prepare bioactive fibrin layers which would both support endothelialization of porcine pericardium and enhance differentiation and maturation of the endothelial cells seeded. As a material for surface adjustments we used layers of fibrin with/without heparin and some of them with adsorbed or chemically bound FGF2, VEGF or their combination. Fibrin assemblies were prepared in 24-well cell culture plate and were seeded with HSVEC (Human Saphenous Vein Endothelial Cells) at a density of 20,000 cells per well in EGM-2 medium with 0.5% FS and without heparin, without FGF2 and without VEGF; medium was supplemented with aprotinin (200 U/mL). As a control, surface polystyrene (PS) was used. Fibrin was also used as homogeneous impregnation of the decellularized porcine pericardium throughout the scaffolds. Morphology, density, and viability of the seeded endothelial cells were observed from micrographs after staining the samples by LIVE/DEAD cytotoxicity/viability assay kit on the days 1, 3, and 7. Endothelial cells were immunocytochemically stained for proteins involved in cell adhesion, i.e. alphaV integrin, vinculin, and VE-cadherin, markers of endothelial cells differentiation and maturation, i.e. von Willebrand factor and CD31, and for extracellular matrix proteins typically produced by endothelial cells, i.e. type IV collagen and laminin. The staining intensities were subsequently quantified using a software. HSVEC cells grew on each of the prepared surfaces better than on control surface. They reached confluency. The highest cell densities were obtained on the surface of fibrin with heparin and both grow factors used together. Intensity of alphaV integrins staining was highest on samples with remained fibrin layer, i.e. on layers with lower cell densities, i.e. on fibrin without heparin. Vinculin staining was apparent, but was rather diffuse, on fibrin with both FGF2 and VEGF and on control PS. Endothelial cells on all samples were positively stained for von Willebrand factor and CD31. VE-cadherin receptors clusters were best developed on fibrin with heparin and growth factors. Significantly stronger staining of type IV collagen was observed on fibrin with heparin and both growth factors. Endothelial cells on all samples produced laminin-1. Decellularized pericardium was homogeneously filled with fibrin structures. These fibrin-modified pericardium samples will be further seeded with cells and cultured in a bioreactor. Fibrin layers with/without heparin and with adsorbed or chemically bound FGF2, VEGF or their combination are good surfaces for endothelialization of cardiovascular prostheses or porcine pericardium based heart valves. Supported by the Ministry of Health, grants No15-29153A and 15-32497A, and the Grant Agency of the Czech Republic, project No. P108/12/G108.

Keywords: aortic valves prosthesis, FGF2, heparin, HSVEC cells, VEGF

Procedia PDF Downloads 239
91 Unauthorized License Verifier and Secure Access to Vehicle

Authors: G. Prakash, L. Mohamed Aasiq, N. Dhivya, M. Jothi Mani, R. Mounika, B. Gomathi

Abstract:

In our day to day life, many people met with an accident due to various reasons like over speed, overload in the vehicle, violation of the traffic rules, etc. Driving license system is difficult task for the government to monitor. To prevent non-licensees from driving who are causing most of the accidents, a new system is proposed. The proposed system consists of a smart card capable of storing the license details of a particular person. Vehicles such as cars, bikes etc., should have a card reader capable of reading the particular license. A person, who wishes to drive the vehicle, should insert the card (license) in the vehicle and then enter the password in the keypad. If the license data stored in the card and database about the entire license holders in the microcontroller matches, he/she can proceed for ignition after the automated opening of the fuel tank valve, otherwise the user is restricted to use the vehicle. Moreover, overload detector in our proposed system verifies and then prompts the user to avoid overload before driving. This increases the security of vehicles and also ensures safe driving by preventing accidents.

Keywords: license, verifier, EEPROM, secure, overload detection

Procedia PDF Downloads 221
90 Control Strategy of Solar Thermal Cooling System under the Indonesia Climate

Authors: Budihardjo Sarwo Sastrosudiro, Arnas Lubis, Muhammad Idrus Alhamid, Nasruddin Jusuf

Abstract:

Solar thermal cooling system was installed on Mechanical Research Center (MRC) Building that is located in Universitas Indonesia, Depok, Indonesia. It is the first cooling system in Indonesia that utilizes solar energy as energy input combined with natural gas; therefore, the control system must be appropriated with the climates. In order to stabilize the cooling capacity and also to maximize the use of solar energy, the system applies some controllers. Constant flow rate and on/off controller are applied for the hot water, chilled water and cooling water pumps. The hot water circulated by pump when the solar radiation is over than 400W/m2, and the chilled water is continually circulated by pump and its temperature is kept constant 7 °C by absorption chiller. The cooling water is also continually circulated until the outlet temperature of cooling tower below than 27 oC. Furthermore, the three-way valve is used to control the hot water for generate vapor on absorption chiller. The system performance using that control system is shown in this study results.

Keywords: absorption chiller, control system, solar cooling, solar energy

Procedia PDF Downloads 244
89 Automation Test Method and HILS Environment Configuration for Hydrogen Storage System Management Unit Verification

Authors: Jaejeogn Kim, Jeongmin Hong, Jungin Lee

Abstract:

The Hydrogen Storage System Management Unit (HMU) is a controller that manages hydrogen charging and storage. It detects hydrogen leaks and tank pressure and temperature, calculates the charging concentration and remaining amount, and controls the opening and closing of the hydrogen tank valve. Since this role is an important part of the vehicle behavior and stability of Fuel Cell Electric Vehicles (FCEV), verifying the HMU controller is an essential part. To perform verification under various conditions, it is necessary to increase time efficiency based on an automated verification environment and increase the reliability of the controller by applying numerous test cases. To this end, we introduce the HMU controller automation verification method by applying the HILS environment and an automation test program with the ASAM XIL standard.

Keywords: HILS, ASAM, fuel cell electric vehicle, automation test, hydrogen storage system

Procedia PDF Downloads 27
88 Hypocalcaemia Inducing Heart Failure: A Rare Presentation

Authors: A. Kherraf, M. Bouziane, L. Azzouzi, R. Habbal

Abstract:

Introduction: Hypocalcaemia is a rare cause of heart failure. We report the clinical case of a young patient with reversible dilated cardiomyopathy secondary to hypocalcaemia in the context of hyperparathyroidism. Clinical case: We report the clinical case of a 23-year-old patient with a history of thyroidectomy for papillary thyroid carcinoma 3 years previously, who presented to the emergency room with a progressive onset dyspnea and edema of the lower limbs. Clinical examination showed hypotension at 90/70 mmHg, tachycardia at 102 bpm, and edema of the lower limbs. The ECG showed a regular sinus rhythm with a prolonged corrected QT interval to 520ms. The chest x-ray showed cardiomegaly. Echocardiography revealed dilated cardiomyopathy with biventricular dysfunction and a left ventricular ejection fraction of 45%, as well as moderate mitral insufficiency by restriction of the posterior mitral leaflet, moderate tricuspid insufficiency, and a dilated inferior vena cava with a pulmonary arterial pressure estimated at 46 mmHg. Blood tests revealed severe hypocalcemia at 38 mg / l with normal albumin and thyroxine levels, as well as hyperphosphatemia and increased TSH. The patient received calcium intake and vitamin D supplementation and was treated with beta blockers, ACE inhibitors, and diuretics with good progress and progressive normalization of cardiac function. Discussion: The cardiovascular manifestations of hypocalcaemia usually appear with deeply low serum calcium levels. This can lead to hypotension, arrhythmias, ventricular fibrillation, prolonged QT interval, or even heart failure. Heart failure is a rare and serious complication of hypocalcemia but most often characterized by complete normalization of myocardial function after treatment. The etiology of the hypocalcaemia, in this case, was probably related to accidental parathyroid removal during thyroidectomy. This is why careful monitoring of calcium levels is recommended after surgery. Conclusion: Hypocalcemic heart failure is rare but reversible heart disease. Systematic monitoring of serum calcium should be performed in all patients after thyroid surgery to avoid any complications related to hypoparathyroidism.

Keywords: hypocalcemia, heart failure, thyroid surgery, hypoparathyroidism

Procedia PDF Downloads 119
87 By-Product Alcohol: Fusel Oil as an Alternative Fuel in Spark Ignition Engine

Authors: Omar Awad, R. Mamat, F. Yusop, M. M. Noor, I. M. Yusri

Abstract:

Fusel oil is a by-product obtained through the fermentation of some agricultural products. The fusel oil properties are closer to other alternative combustible types and the limited number of studies on the use of fusel oil as an alcohol derivative in SI engines constitutes to the base of this study. This paper experimentally examined the impacts of a by-product of alcohol, which is fusel oil by blending it with gasoline, on engine performance, combustion characteristics, and emissions in a 4-cylinder SI engine. The test was achieved at different engine speeds and a 60 % throttle valve (load). As results, brake power, BTE, and BSFC of F10 are higher at all engine speeds. Maximum engine BTE was 33.9%, at the lowest BSFC with F10. Moreover, it is worth seeing that the F10 under rich air-fuel ratio has less variation of COVIMEP compared to the F20 and gasoline. F10 represents shorter combustion duration, thereby, the engine power increased. NOx emission for F10 at 4500 rpm was lower than gasoline. The highest value of HC emission is obtained with F10 compared to gasoline and F20 with an average increase of 11% over the engine speed range. CO and CO2 emissions increased when using fusel oil blends.

Keywords: fusel oil, spark ignition engine, by-product alcohol, combustion characteristics, engine emissions, alternative fuel

Procedia PDF Downloads 452
86 Experimental Investigation on Effect of the Zirconium + Magnesium Coating of the Piston and Valve of the Single-Cylinder Diesel Engine to the Engine Performance and Emission

Authors: Erdinç Vural, Bülent Özdalyan, Serkan Özel

Abstract:

The four-stroke single cylinder diesel engine has been used in this study, the pistons and valves of the engine have been stabilized, the aluminum oxide (Al2O3) in different ratios has been added in the power of zirconium (ZrO2) magnesium oxide (MgO), and has been coated with the plasma spray method. The pistons and valves of the combustion chamber of the engine are coated with 5 different (ZrO2 + MgO), (ZrO2 + MgO + 25% Al2O3), (ZrO2 + MgO + 50% Al2O3), (ZrO2 + MgO + 75% Al2O3), (Al2O3) sample. The material tests have been made for each of the coated engine parts with the scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX) and X-ray diffraction (XRD) using Cu Kα radiation surface analysis methods. The engine tests have been repeated for each sample in any electric dynamometer in full power 1600 rpm, 2000 rpm, 2400 rpm and 2800 rpm engine speeds. The material analysis and engine tests have shown that the best performance has been performed with (ZrO2 + MgO + 50% Al2O3). Thus, there is no significant change in HC and Smoke emissions, but NOx emission is increased, as the engine improves power, torque, specific fuel consumption and CO emissions in the tests made with sample A3.

Keywords: ceramic coating, material characterization, engine performance, exhaust emissions

Procedia PDF Downloads 345
85 Modified Bat Algorithm for Economic Load Dispatch Problem

Authors: Daljinder Singh, J.S.Dhillon, Balraj Singh

Abstract:

According to no free lunch theorem, a single search technique cannot perform best in all conditions. Optimization method can be attractive choice to solve optimization problem that may have exclusive advantages like robust and reliable performance, global search capability, little information requirement, ease of implementation, parallelism, no requirement of differentiable and continuous objective function. In order to synergize between exploration and exploitation and to further enhance the performance of Bat algorithm, the paper proposed a modified bat algorithm that adds additional search procedure based on bat’s previous experience. The proposed algorithm is used for solving the economic load dispatch (ELD) problem. The practical constraint such valve-point loading along with power balance constraints and generator limit are undertaken. To take care of power demand constraint variable elimination method is exploited. The proposed algorithm is tested on various ELD problems. The results obtained show that the proposed algorithm is capable of performing better in majority of ELD problems considered and is at par with existing algorithms for some of problems.

Keywords: bat algorithm, economic load dispatch, penalty method, variable elimination method

Procedia PDF Downloads 443