Search results for: R. Habbal
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4

Search results for: R. Habbal

4 Correlation Between Diastolic Function and Lower GLS in Hypertensive Patients

Authors: A. Kherraf, S. Ouarrak, L. Azzouzi, R. Habbal

Abstract:

Introduction: Preserved LVEF heart failure is an important cause of mortality and morbidity in hypertensive patients. A strong correlation between impaired diastolic function and longitudinal systolic dysfunction. could have several explanations, first, the diastole is an energy dependent process, especially during its first phase, it also includes active systolic components during the phase of iso volumetric relaxation, in addition, the impairment of the intrinsic myocytic function is part of hypertensive pathology as evidenced by recent studies. METHODS AND MATERIALS: This work consists of performing in a series of 333 hypertensive patients (aged 25 to 75 years) a complete echocardiographic study, including LVEF by Simpson biplane method, the calculation of the indexed left ventricular mass, the analysis of the diastolic function, and finally, the study of the longitudinal deformation of the LV by the technique of speckletracking (calculation of the GLS). Patients with secondary hypertension, leaky or stenosing valve disease, arrhythmia, and a history of coronary insufficiency were excluded from this study. RESULTS: Of the 333 hypertensive patients, 225 patients (67.5%) had impaired diastolic function, of which 60 patients (18%) had high filling pressures. 49.39% had echocardigraphic HVG, Almost all of these patients (60 patients) had low GLS. There is a statistically very significant relationship between lower GLS and increased left ventricular filling pressures in hypertensive patients. These results suggest that increased filling pressures are closely associated with atrioventricular interaction in patients with hypertension, with a strong correlation with impairment of longitudinal systolic function and diastolic function CONCLUSION: Overall, a linear relationship is established between increased left ventricular mass, diastolic dysfunction, and longitudinal LV systolic dysfunction

Keywords: hypertension, diastolic function, left ventricle, heart failure

Procedia PDF Downloads 96
3 Pulmonary Embolism Indicative of Myxoma of the Right Atrium

Authors: A. Kherraf, M. Bouziane, A. Drighil, L. Azzouzi, R. Habbal

Abstract:

Objective: Myxomas are rare heart tumors most commonly found in the left atrium. The purpose of this observation is to report a rare case of myxoma of the right atrium revealed by pulmonary embolism. Observation: A 34-year-old patient with no history presented to the emergency room with sudden onset dyspnea. Clinical examination showed arterial pressure at 110/70mmHg, tachycardia at 110bpm, and 90% oxygen saturation. The ECG enrolled in incomplete right bundle branch block. The radio-thorax was normal. Echocardiography revealed the presence of a large homogeneous intra-OD mass, contiguous to the inter-atrial septum, prolapsing through the tricuspid valve, and causing mild tricuspid insufficiency, with dilation of the right ventricle and retained systolic function with PAPs estimated at 45mmHg. A chest scan was performed, revealing the presence of right segmental pulmonary embolism. The patient was put under anticoagulant and underwent surgical resection of the mass; its pathological examination concluded to a myxoma. The post-operative consequences were simple, without recurrence of the mass after one year follow-up. Discussion: Myxomas represent 50% of heart tumors. Most often, they originate in the left atrium, and more rarely in the right atrium or the ventricles. Myxoma of the right atrium can be responsible for life-threatening pulmonary embolism. The most predictive factor for embolization remains the morphology of the myxomas; papillary or villous myxomas are the most friable. Surgery is the standard treatment, with regular postoperative follow-up to detect recurrence. Conclusion: Myxomas of the right atrium are a rare location for these tumors. Pulmonary embolism is the main complication and should routinely involve careful study of the right chambers on echocardiography.

Keywords: pulmonary embolism, myxoma, right atrium, heart tumors

Procedia PDF Downloads 103
2 Hypocalcaemia Inducing Heart Failure: A Rare Presentation

Authors: A. Kherraf, M. Bouziane, L. Azzouzi, R. Habbal

Abstract:

Introduction: Hypocalcaemia is a rare cause of heart failure. We report the clinical case of a young patient with reversible dilated cardiomyopathy secondary to hypocalcaemia in the context of hyperparathyroidism. Clinical case: We report the clinical case of a 23-year-old patient with a history of thyroidectomy for papillary thyroid carcinoma 3 years previously, who presented to the emergency room with a progressive onset dyspnea and edema of the lower limbs. Clinical examination showed hypotension at 90/70 mmHg, tachycardia at 102 bpm, and edema of the lower limbs. The ECG showed a regular sinus rhythm with a prolonged corrected QT interval to 520ms. The chest x-ray showed cardiomegaly. Echocardiography revealed dilated cardiomyopathy with biventricular dysfunction and a left ventricular ejection fraction of 45%, as well as moderate mitral insufficiency by restriction of the posterior mitral leaflet, moderate tricuspid insufficiency, and a dilated inferior vena cava with a pulmonary arterial pressure estimated at 46 mmHg. Blood tests revealed severe hypocalcemia at 38 mg / l with normal albumin and thyroxine levels, as well as hyperphosphatemia and increased TSH. The patient received calcium intake and vitamin D supplementation and was treated with beta blockers, ACE inhibitors, and diuretics with good progress and progressive normalization of cardiac function. Discussion: The cardiovascular manifestations of hypocalcaemia usually appear with deeply low serum calcium levels. This can lead to hypotension, arrhythmias, ventricular fibrillation, prolonged QT interval, or even heart failure. Heart failure is a rare and serious complication of hypocalcemia but most often characterized by complete normalization of myocardial function after treatment. The etiology of the hypocalcaemia, in this case, was probably related to accidental parathyroid removal during thyroidectomy. This is why careful monitoring of calcium levels is recommended after surgery. Conclusion: Hypocalcemic heart failure is rare but reversible heart disease. Systematic monitoring of serum calcium should be performed in all patients after thyroid surgery to avoid any complications related to hypoparathyroidism.

Keywords: hypocalcemia, heart failure, thyroid surgery, hypoparathyroidism

Procedia PDF Downloads 112
1 Collaborative Data Refinement for Enhanced Ionic Conductivity Prediction in Garnet-Type Materials

Authors: Zakaria Kharbouch, Mustapha Bouchaara, F. Elkouihen, A. Habbal, A. Ratnani, A. Faik

Abstract:

Solid-state lithium-ion batteries have garnered increasing interest in modern energy research due to their potential for safer, more efficient, and sustainable energy storage systems. Among the critical components of these batteries, the electrolyte plays a pivotal role, with LLZO garnet-based electrolytes showing significant promise. Garnet materials offer intrinsic advantages such as high Li-ion conductivity, wide electrochemical stability, and excellent compatibility with lithium metal anodes. However, optimizing ionic conductivity in garnet structures poses a complex challenge, primarily due to the multitude of potential dopants that can be incorporated into the LLZO crystal lattice. The complexity of material design, influenced by numerous dopant options, requires a systematic method to find the most effective combinations. This study highlights the utility of machine learning (ML) techniques in the materials discovery process to navigate the complex range of factors in garnet-based electrolytes. Collaborators from the materials science and ML fields worked with a comprehensive dataset previously employed in a similar study and collected from various literature sources. This dataset served as the foundation for an extensive data refinement phase, where meticulous error identification, correction, outlier removal, and garnet-specific feature engineering were conducted. This rigorous process substantially improved the dataset's quality, ensuring it accurately captured the underlying physical and chemical principles governing garnet ionic conductivity. The data refinement effort resulted in a significant improvement in the predictive performance of the machine learning model. Originally starting at an accuracy of 0.32, the model underwent substantial refinement, ultimately achieving an accuracy of 0.88. This enhancement highlights the effectiveness of the interdisciplinary approach and underscores the substantial potential of machine learning techniques in materials science research.

Keywords: lithium batteries, all-solid-state batteries, machine learning, solid state electrolytes

Procedia PDF Downloads 20