Search results for: cigarette smoke.
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 207

Search results for: cigarette smoke.

147 A Comparative Study of Black Carbon Emission Characteristics from Marine Diesel Engines Using Light Absorption Method

Authors: Dongguk Im, Gunfeel Moon, Younwoo Nam, Kangwoo Chun

Abstract:

Recognition of the needs about protecting environment throughout worldwide is widespread. In the shipping industry, International Maritime Organization (IMO) has been regulating pollutants emitted from ships by MARPOL 73/78. Recently, the Marine Environment Protection Committee (MEPC) of IMO, at its 68th session, approved the definition of Black Carbon (BC) specified by the following physical properties (light absorption, refractory, insolubility and morphology). The committee also agreed to the need for a protocol for any voluntary measurement studies to identify the most appropriate measurement methods. Filter Smoke Number (FSN) based on light absorption is categorized as one of the IMO relevant BC measurement methods. EUROMOT provided a FSN measurement data (measured by smoke meter) of 31 different engines (low, medium and high speed marine engines) of member companies at the 3rd International Council on Clean Transportation (ICCT) workshop on marine BC. From the comparison of FSN, the results indicated that BC emission from low speed marine diesel engines was ranged from 0.009 to 0.179 FSN and it from medium and high speed marine diesel engine was ranged 0.012 to 3.2 FSN. In consideration of measured the low FSN from low speed engine, an experimental study was conducted using both a low speed marine diesel engine (2 stroke, power of 7,400 kW at 129 rpm) and a high speed marine diesel engine (4 stroke, power of 403 kW at 1,800 rpm) under E3 test cycle. The results revealed that FSN was ranged from 0.01 to 0.16 and 1.09 to 1.35 for low and high speed engines, respectively. The measurement equipment (smoke meter) ranges from 0 to 10 FSN. Considering measurement range of it, FSN values from low speed engines are near the detection limit (0.002 FSN or ~0.02 mg/m3). From these results, it seems to be modulated the measurement range of the measurement equipment (smoke meter) for enhancing measurement accuracy of marine BC and evaluation on performance of BC abatement technologies.

Keywords: black carbon, filter smoke number, international maritime organization, marine diesel engine (two and four stroke), particulate matter

Procedia PDF Downloads 244
146 An Intercontinental Comparison of Delay Discounting for Real and Hypothetical Money and Cigarettes among Cigarette Smokers

Authors: Steven R. Lawyer, Tereza Prihodova, Katerina Prihodova

Abstract:

Delay discounting (DD) is one of the most frequently used behavioral-economic measures of impulsive choice, but there are few cross-cultural comparisons of discounting, and to the best of our knowledge, none compare patterns of DD across different commodities or compare real and hypothetical rewards across cultures. The purpose of this study was to compare patterns of DD for both real and hypothetical money and cigarettes among participants in the USA and the Czech Republic. Adult smokers from the United States and the Czech Republic completed standard measures of DD for hypothetical and real money (~$10USD) and cigarettes (1 pack, or 20 cigarettes). Contrary to data from the USA sample, Czech Republic participants discounted the value of real money steeper than hypothetical money, though this could be related to the relatively poor fit of the hyperbolic decay function to DD for hypothetical money in the Czech sample. These findings suggest that there might be cultural differences in delay discounting that warrant further attention.

Keywords: delay discounting, temporal discounting, cigarette smoking, real rewards, hypothetical rewards

Procedia PDF Downloads 158
145 A Systematic Review for the Association between Active Smoking and Latent Tuberculosis Infection

Authors: Pui Hong Chung, Wing Chi Ho, Jun Li, Cyrus Leung, Ek Yeoh

Abstract:

Background: Cigarette smoking is associated with poor tuberculosis (TB) outcomes in terms of progression of active TB, relapse of TB and TB-related mortality, but the association with latent tuberculosis infection (LTBI) is unclear. The systematic review conducted aimed at studying the association between active smoking and LTBI, and likelihood of dose-response relationship. Methods: Two independent reviewers searched three electronic databases comprising PudMed, Medline by EBSCOHOST, ExcerptaMedica Database (EMBASE), from inception up to 31st Dec 2015 for studies reporting data on current smoking and the LTBI with tuberculin skin test (TST) or interferon-γ release assays (IGRAs) results, comparing the odds ratios (ORs) of outcome measure of TST or IGRAs among current smokers with 95% confidence intervals (CI). Results: Seven studies were identified, including six cross-sectional studies and one longitudinal cohort study. The outcome measures from three studies were in TST, three studies in IGRAs and one for both tests. For TST, OR ranging from 1.39 to 3.40 (95% CI) with all studies shown positive association between cigarette smoking and LTBI. For IGRAs, OR ranging from 0.47 to 1.89 (95% CI) with one study shown the negative association that might be related to impaired interferon-gamma production in immunosuppressive persons. One identified study demonstrated positive dose-response relationship in TST result. Conclusions: Cigarette smoking is likely to be a risk factor of LTBI. There is the important implication for TB and tobacco control program to halt TB by empowering public health policy. Further study is also needed to provide more evidence of the dose-response model/relationship.

Keywords: latent tuberculosis infection, systematic review, active smoking, model

Procedia PDF Downloads 226
144 Substitution Effects of Baijiu and Cigarette Consumption on Anti-Corruption Campaigns: Evidence from China

Authors: Xiaohan Gu

Abstract:

China is perceived as one of the most politically corrupt countries in the world. The 2021 Transparency International Corruption Perceptions Index China (RPC) ranks the country in 66th place out of 180 countries in the Index, where the 180 countries are perceived to have the most corrupt public sector. This paper proposes a theory on the impact of corruption on the consumption of luxury goods. We test the theory and evaluate the effectiveness of China’s anti-corruption campaign in 2012 by conducting a difference-in-differences analysis of product-city-level alcohol and cigarette consumption from 2013 to 2022. We find that the campaign increased sales of middle-end baijiu and cigarettes but decreased sales of luxury baijiu and cigarettes, contrasting with the trend for low-end products. This substitution pattern may be attributable to decreased public spending on luxury goods. This substitution pattern is moderated by officials’ wages and anti-corruption efforts, which supports the theoretical predictions.

Keywords: substitution effect, baijiu, corruption, anti-corruption, chinese political connection

Procedia PDF Downloads 49
143 Long Distance Aspirating Smoke Detection for Large Radioactive Areas

Authors: Michael Dole, Pierre Ninin, Denis Raffourt

Abstract:

Most of the CERN’s facilities hosting particle accelerators are large, underground and radioactive areas. All fire detection systems installed in such areas, shall be carefully studied to cope with the particularities of this stringent environment. The detection equipment usually chosen by CERN to secure these underground facilities are based on air sampling technology. The electronic equipment is located in non-radioactive areas whereas air sampling networks are deployed in radioactive areas where fire detection is required. The air sampling technology provides very good detection performances and prevent the "radiation-to-electronic" effects. In addition, it reduces the exposure to radiations of maintenance workers and is permanently available during accelerator operation. In order to protect the Super Proton Synchrotron and its 7 km tunnels, a specific long distance aspirating smoke detector has been developed to detect smoke at up to 700 meters between electronic equipment and the last air sampling hole. This paper describes the architecture, performances and return of experience of the long distance fire detection system developed and installed to secure the CERN Super Proton Synchrotron tunnels.

Keywords: air sampling, fire detection, long distance, radioactive areas

Procedia PDF Downloads 129
142 Application of Non-Smoking Areas in Hospitals

Authors: Nur Inayah Ismaniar, Sukri Palutturi, Ansariadi, Atjo Wahyu

Abstract:

Background: In various countries in the world, the problem of smoking is now considered something serious because of the effects of smoking which can not only lead to addiction but also have the potential to harm health. Public health authorities have concluded that one solution that can be done to protect the public from active smokers is to issue a policy that requires public facilities to be completely smoke-free. The hospital is one of the public facilities that has been designated as a smoke-free area. However, the implementation and maintenance of a successful program based on a smoke-free hospital are still considered an ongoing challenge worldwide due to the very low level of adherence. The low level of compliance with this smoke-free policy is also seen in other public facilities. The purpose of the literature review is to review the level of compliance with the application of the Non-Smoking Area policy, how this policy has succeeded in reducing smoking activity in hospitals, and what factors lead to such compliance in each country in the world. Methods: A literature review of articles was carried out on all types of research methods, both qualitative and quantitative. The sample is all subjects who are in the research location, which includes patients, staff and hospital visitors. Results: Various variations in the level of compliance were found in various kinds of literature. The literature with the highest level of compliance is 88.4%. Furthermore, several determinants that are known to affect the compliance of the Non-Smoking Area policies in hospitals include communication, information, knowledge, perceptions, interventions, attitudes and support. Obstacles to its enforcement are the absence of sanctions against violators of the Non-Smoking Area policy, the ineffectiveness of the function of policymakers in hospitals, and negative perceptions of smoking related to mental health. Conclusion: Violations of the Non-Smoking Area policy are often committed by the hospital staff themselves, which makes it difficult for this policy to be fully enforced at various points in the hospital.

Keywords: health policy, non-smoking area, hospital, implementation

Procedia PDF Downloads 61
141 Computational Fluid Dynamics Simulation to Study the Effect of Ambient Temperature on the Ventilation in a Metro Tunnel

Authors: Yousef Almutairi, Yajue Wu

Abstract:

Various large-scale trends have characterized the current century thus far, including increasing shifts towards urbanization and greater movement. It is predicted that there will be 9.3 billion people on Earth in 2050 and that over two-thirds of this population will be city dwellers. Moreover, in larger cities worldwide, mass transportation systems, including underground systems, have grown to account for the majority of travel in those settings. Underground networks are vulnerable to fires, however, endangering travellers’ safety, with various examples of fire outbreaks in this setting. This study aims to increase knowledge of the impacts of extreme climatic conditions on fires, including the role of the high ambient temperatures experienced in Middle Eastern countries and specifically in Saudi Arabia. This is an element that is not always included when assessments of fire safety are made (considering visibility, temperatures, and flows of smoke). This paper focuses on a tunnel within Riyadh’s underground system as a case study and includes simulations based on computational fluid dynamics using ANSYS Fluent, which investigates the impact of various ventilation systems while identifying smoke density, speed, pressure and temperatures within this tunnel.

Keywords: fire, subway tunnel, CFD, mechanical ventilation, smoke, temperature, harsh weather

Procedia PDF Downloads 78
140 Healthcare Fire Disasters: Readiness, Response and Resilience Strategies: A Real-Time Experience of a Healthcare Organization of North India

Authors: Raman Sharma, Ashok Kumar, Vipin Koushal

Abstract:

Healthcare facilities are always seen as places of haven and protection for managing the external incidents, but the situation becomes more difficult and challenging when such facilities themselves are affected from internal hazards. Such internal hazards are arguably more disruptive than external incidents affecting vulnerable ones, as patients are always dependent on supportive measures and are neither in a position to respond to such crisis situation nor do they know how to respond. The situation becomes more arduous and exigent to manage if, in case critical care areas like Intensive Care Units (ICUs) and Operating Rooms (OR) are convoluted. And, due to these complexities of patients’ in-housed there, it becomes difficult to move such critically ill patients on immediate basis. Healthcare organisations use different types of electrical equipment, inflammable liquids, and medical gases often at a single point of use, hence, any sort of error can spark the fire. Even though healthcare facilities face many fire hazards, damage caused by smoke rather than flames is often more severe. Besides burns, smoke inhalation is primary cause of fatality in fire-related incidents. The greatest cause of illness and mortality in fire victims, particularly in enclosed places, appears to be the inhalation of fire smoke, which contains a complex mixture of gases in addition to carbon monoxide. Therefore, healthcare organizations are required to have a well-planned disaster mitigation strategy, proactive and well prepared manpower to cater all types of exigencies resulting from internal as well as external hazards. This case report delineates a true OR fire incident in Emergency Operation Theatre (OT) of a tertiary care multispecialty hospital and details the real life evidence of the challenges encountered by OR staff in preserving both life and property. No adverse event was reported during or after this fire commotion, yet, this case report aimed to congregate the lessons identified of the incident in a sequential and logical manner. Also, timely smoke evacuation and preventing the spread of smoke to adjoining patient care areas by opting appropriate measures, viz. compartmentation, pressurisation, dilution, ventilation, buoyancy, and airflow, helped to reduce smoke-related fatalities. Henceforth, precautionary measures may be implemented to mitigate such incidents. Careful coordination, continuous training, and fire drill exercises can improve the overall outcomes and minimize the possibility of these potentially fatal problems, thereby making a safer healthcare environment for every worker and patient.

Keywords: healthcare, fires, smoke, management, strategies

Procedia PDF Downloads 42
139 Feminist Perspective: Negotiating Subverted Feminine Self in Moth Smoke by Mohsin Hamid

Authors: Sumaira Mukhtar

Abstract:

The present research aims at the discussion of the subversion of the hegemony of the feminine self in the text Moth Smoke by a Pakistani novelist Mohsin Hamid. It presents the notion of the subversion of the grand narratives of the ‘positioning’ of feminine identity in Pakistani patriarchal society by presenting a de-stereotyped personality of Mumtaz, the protagonist in Moth Smoke. The dominant masculine traits in Mumtaz’s personality have been negotiated since she is an untraditional female character in the novel. In this regard, the researcher has taken a feministic stance in this study by presenting the proposition that subaltern can also speak. Mumtaz’s character reminds one of Hedda from Henrik Ibsen’s play Hedda Gabler. So, the masculine traits in Mumtaz’s personality have also been compared with Hedda’s. Besides, the research study will also bring into notice that how that in the postmodern scenario, marginalization of the women have been responded back by women and hereby Mumtaz by uplifting her social status and class. Her de-stereotyped feminine self has been reinforced by the dialogues and incidents in the text. This research is qualitative in design and is based on the textual analysis. An interpretive research method has also been utilized since the researcher has tried to decode the text in supporting the notion of de-stereotyping of feminine self. This research would add to the body of Pakistani literature and Feministic theory.

Keywords: de-stereotyped, feminine identity, marginalization, masculine traits

Procedia PDF Downloads 134
138 Clara Cell Secretory Protein 16 Serum Level Decreases in Patients with Non-Smoking-Related Chronic Obstructive Pulmonary Diseases (COPD)

Authors: Lian Wu, Mervyn Merrilees

Abstract:

Chronic Obstructive Pulmonary Disease (COPD) is a worldwide problem, characterized by irreversible and progressive airflow obstruction. In New Zealand, it is currently the 4th commonest cause of death and exacerbations of COPD are a frequent cause of admission to hospital. Serum levels of Clara cell secretory protein-16 (CC-16) are believed to represent Clara cell toxicity. More recently, CC-16 has been found to be associated with smoker COPD. It is produced almost exclusively by non-ciliated Clara cells in the airways, and its primary function is to protect the lungs against oxidative stress and carcinogenesis. After acute exposure to cigarette smoke, serum levels of CC-16 become elevated. CC16 is a potent natural immune-suppressor and anti-inflammatory agent. In vitro, CC16 inhibits both monocyte and polymorphonuclear neutrophils chemotaxis and phagocytosis. CC16 also inhibits fibroblast chemotaxis. However, the role of CC-16 in non-smoking related COPD is still not clear. In this study, we investigated serum CC-16 levels in non-smoking related COPD. Methods: We compared non-smoker patients with COPD (FEV1<60% of predicted, FEV1/FVC <0.7, n=100) and individuals with normal lung function FEV1≥ 80% of predicted and FEV1/FVC≥ 0.7, n=80). All subjects had no smoking history. CC-16 was measured by ELISA. Results and conclusion: Serum CC-16 levels are reduced in individuals with non-smoking related COPD, and there is a weak correlation with disease severity in non-smoking related COPD group compared to non-smoker controls.

Keywords: COPD, CC-16, ELISA, non-smoking-related COPD

Procedia PDF Downloads 352
137 Tobacco Taxation and the Heterogeneity of Smokers' Responses to Price Increases

Authors: Simone Tedeschi, Francesco Crespi, Paolo Liberati, Massimo Paradiso, Antonio Sciala

Abstract:

This paper aims at contributing to the understanding of smokers’ responses to cigarette prices increases with a focus on heterogeneity, both across individuals and price levels. To do this, a stated preference quasi-experimental design grounded in a random utility framework is proposed to evaluate the effect on smokers’ utility of the price level and variation, along with social conditioning and health impact perception. The analysis is based on individual-level data drawn from a unique survey gathering very detailed information on Italian smokers’ habits. In particular, qualitative information on the individual reactions triggered by changes in prices of different magnitude and composition are exploited. The main findings stemming from the analysis are the following; the average price elasticity of cigarette consumption is comparable with previous estimates for advanced economies (-.32). However, the decomposition of this result across five latent-classes of smokers, reveals extreme heterogeneity in terms of price responsiveness, implying a potential price elasticity that ranges between 0.05 to almost 1. Such heterogeneity is in part explained by observable characteristics such as age, income, gender, education as well as (current and lagged) smoking intensity. Moreover, price responsiveness is far from being independent from the size of the prospected price increase. Finally, by comparing even and uneven price variations, it is shown that uniform across-brand price increases are able to limit the scope of product substitutions and downgrade. Estimated price-response heterogeneity has significant implications for tax policy. Among them, first, it provides evidence and a rationale for why the aggregate price elasticity is likely to follow a strictly increasing pattern as a function of the experienced price variation. This information is crucial for forecasting the effect of a given tax-driven price change on tax revenue. Second, it provides some guidance on how to design excise tax reforms to balance public health and revenue goals.

Keywords: smoking behaviour, preference heterogeneity, price responsiveness, cigarette taxation, random utility models

Procedia PDF Downloads 129
136 Development of a Fire Analysis Drone for Smoke Toxicity Measurement for Fire Prediction and Management

Authors: Gabrielle Peck, Ryan Hayes

Abstract:

This research presents the design and creation of a drone gas analyser, aimed at addressing the need for independent data collection and analysis of gas emissions during large-scale fires, particularly wasteland fires. The analyser drone, comprising a lightweight gas analysis system attached to a remote-controlled drone, enables the real-time assessment of smoke toxicity and the monitoring of gases released into the atmosphere during such incidents. The key components of the analyser unit included two gas line inlets connected to glass wool filters, a pump with regulated flow controlled by a mass flow controller, and electrochemical cells for detecting nitrogen oxides, hydrogen cyanide, and oxygen levels. Additionally, a non-dispersive infrared (NDIR) analyser is employed to monitor carbon monoxide (CO), carbon dioxide (CO₂), and hydrocarbon concentrations. Thermocouples can be attached to the analyser to monitor temperature, as well as McCaffrey probes combined with pressure transducers to monitor air velocity and wind direction. These additions allow for monitoring of the large fire and can be used for predictions of fire spread. The innovative system not only provides crucial data for assessing smoke toxicity but also contributes to fire prediction and management. The remote-controlled drone's mobility allows for safe and efficient data collection in proximity to the fire source, reducing the need for human exposure to hazardous conditions. The data obtained from the gas analyser unit facilitates informed decision-making by emergency responders, aiding in the protection of both human health and the environment. This abstract highlights the successful development of a drone gas analyser, illustrating its potential for enhancing smoke toxicity analysis and fire prediction capabilities. The integration of this technology into fire management strategies offers a promising solution for addressing the challenges associated with wildfires and other large-scale fire incidents. The project's methodology and results contribute to the growing body of knowledge in the field of environmental monitoring and safety, emphasizing the practical utility of drones for critical applications.

Keywords: fire prediction, drone, smoke toxicity, analyser, fire management

Procedia PDF Downloads 55
135 Microbiological Assessment of Fish Sausages Coated with Smoked-Edible Film, and Stored in Room and Refrigerator Temperatures

Authors: Henny A. Dien, Roike I. Montolalu, Feny Mentang, Jupni Keno, Reynerd S. Burdam, Siegfried Berhimpon

Abstract:

Fish Sausages became popular nowadays, because of high nutritious and low in cholesterol. However, this food is also highly perishable and often contaminated by pathogen bacteria. Edible film was made from myofibril of Black Marlin (Makaira indica) waste, with addition of liquid smoke 0.8%. The aim of this study were to determine the TPC, total coliform and Escherichia coli in fish sausages coated with smoked edible film, and stored in room temperature (26-29oC), and refrigerator (5-10oC). Results shown that TPC in fish sausages coated with smoked edible film were lower than that of without coated, both for storage in room temperature and in refrigerator. Total coliform in coated with smoked edible film and stored in room temperature ranged between 7-120 MPN/g (1-4 days), while stored in refrigerator ranged between 7-93 MPN/g (1-6 days); while fish sausages coated with edible film without liquid smoke were 7-240 MPN/g (1-4 days) in room temperature, and 7-150 MPN/g in refrigerator. Total E. coli of fish sausages coated with smoked edible film and stored in room temperature ranged between 3-4 MPN/g (1-4 days), while stored in refrigerator ranged were 3 MPN/g (1-6 days); while fish sausages coated with edible film without smoked both stored in room temperature and in refrigerator, shown total E. coli 3 MPN/g during 4 days in room temperature, and 6 days in refrigerator. Total E. coli of sausages without coated stored in room temperature ranged between 7-24 MPN/g, and that of stored in refrigerator ranged between 3-4 MPN/g.

Keywords: smoke liquid, edible film, coating, sausages

Procedia PDF Downloads 417
134 Fire Smoke Removal over Cu-Mn-Ce Oxide Catalyst with CO₂ Sorbent Addition: Co Oxidation and in-situ CO₂ Sorption

Authors: Jin Lin, Shouxiang Lu, Kim Meow Liew

Abstract:

In a fire accident, fire smoke often poses a serious threat to human safety especially in the enclosed space such as submarine and space-crafts environment. Efficient removal of the hazardous gas products particularly a large amount of CO and CO₂ gases from these confined space is critical for the security of the staff and necessary for the post-fire environment recovery. In this work, Cu-Mn-Ce composite oxide catalysts coupled with CO₂ sorbents were prepared using wet impregnation method, solid-state impregnation method and wet/solid-state impregnation method. The as-prepared samples were tested dynamically and isothermally for CO oxidation and CO₂ sorption and further characterized by the X-ray diffraction (XRD), nitrogen adsorption and desorption, and field emission scanning electron microscopy (FE-SEM). The results showed that all the samples were able to catalyze CO into CO₂ and capture CO₂ in situ by chemisorption. Among all the samples, the sample synthesized by the wet/solid-state impregnation method showed the highest catalytic activity toward CO oxidation and the fine ability of CO₂ sorption. The sample prepared by the solid-state impregnation method showed the second CO oxidation performance, while the coupled sample using the wet impregnation method exhibited much poor CO oxidation activity. The various CO oxidation and CO₂ sorption properties of the samples might arise from the different dispersed states of the CO₂ sorbent in the CO catalyst, owing to the different preparation methods. XRD results confirmed the high-dispersed sorbent phase in the samples prepared by the wet and solid impregnation method, while that of the sample prepared by wet/solid-state impregnation method showed the larger bulk phase as indicated by the high-intensity diffraction peaks. Nitrogen adsorption and desorption results further revealed that the latter sample had a higher surface area and pore volume, which were beneficial for the CO oxidation over the catalyst. Hence, the Cu-Mn-Ce oxide catalyst coupled with CO₂ sorbent using wet/solid-state impregnation method could be a good choice for fire smoke removal in the enclosed space.

Keywords: CO oxidation, CO₂ sorption, preparation methods, smoke removal

Procedia PDF Downloads 110
133 Impact of an Onboard Fire for the Evacuation of a Rolling Stock

Authors: Guillaume Craveur

Abstract:

This study highlights the impact of an onboard fire for the evacuation of a rolling stock. Two fires models are achieved. The first one is a zone model realized with the CFAST software. Then, this fire is imported in a building EXODUS model in order to determine the evacuation time with effects of fire effluents (temperature, smoke opacity, smoke toxicity) on passengers. The second fire is achieved with Fire Dynamics Simulator software. The fire defined is directly imported in the FDS+Evac model which will permit to determine the evacuation time and effects of fire effluents on passengers. These effects will be compared with tenability criteria defined in some standards in order to see if the situation is acceptable. Different power of fire will be underlined to see from what power source the hazard become unacceptable.

Keywords: fire safety engineering, numerical tools, rolling stock, evacuation

Procedia PDF Downloads 174
132 Using the ISO 9705 Room Corner Test for Smoke Toxicity Quantification of Polyurethane

Authors: Gabrielle Peck, Ryan Hayes

Abstract:

Polyurethane (PU) foam is typically sold as acoustic foam that is often used as sound insulation in settings such as night clubs and bars. As a construction product, PU is tested by being glued to the walls and ceiling of the ISO 9705 room corner test room. However, when heat is applied to PU foam, it melts and burns as a pool fire due to it being a thermoplastic. The current test layout is unable to accurately measure mass loss and doesn’t allow for the material to burn as a pool fire without seeping out of the test room floor. The lack of mass loss measurement means gas yields pertaining to smoke toxicity analysis can’t be calculated, which makes data comparisons from any other material or test method difficult. Additionally, the heat release measurements are not representative of the actual measurements taken as a lot of the material seeps through the floor (when a tray to catch the melted material is not used). This research aimed to modify the ISO 9705 test to provide the ability to measure mass loss to allow for better calculation of gas yields and understanding of decomposition. It also aimed to accurately measure smoke toxicity in both the doorway and duct and enable dilution factors to be calculated. Finally, the study aimed to examine if doubling the fuel loading would force under-ventilated flaming. The test layout was modified to be a combination of the SBI (single burning item) test set up inside oof the ISO 9705 test room. Polyurethane was tested in two different ways with the aim of altering the ventilation condition of the tests. Test one was conducted using 1 x SBI test rig aiming for well-ventilated flaming. Test two was conducted using 2 x SBI rigs (facing each other inside the test room) (doubling the fuel loading) aiming for under-ventilated flaming. The two different configurations used were successful in achieving both well-ventilated flaming and under-ventilated flaming, shown by the measured equivalence ratios (measured using a phi meter designed and created for these experiments). The findings show that doubling the fuel loading will successfully force under-ventilated flaming conditions to be achieved. This method can therefore be used when trying to replicate post-flashover conditions in future ISO 9705 room corner tests. The radiative heat generated by the two SBI rigs facing each other facilitated a much higher overall heat release resulting in a more severe fire. The method successfully allowed for accurate measurement of smoke toxicity produced from the PU foam in terms of simple gases such as oxygen depletion, CO and CO2. Overall, the proposed test modifications improve the ability to measure the smoke toxicity of materials in different fire conditions on a large-scale.

Keywords: flammability, ISO9705, large-scale testing, polyurethane, smoke toxicity

Procedia PDF Downloads 43
131 Experimental Investigation of Performance and Emission Characteristics of Using Acetylene Gas in CI Engine

Authors: S. Sivakumar, Ashwin Bala, S. Prithviraj, K. Panthala Rajakumaran, R. Pradeep, J. Udhayakumar

Abstract:

Studies reveal that acetylene gas derived from hydrolysis of calcium carbide has similar properties to that of diesel. However, the self-ignition temperature of acetylene gas is higher than that of diesel. Early investigations reveal that acetylene gas could be used as alternative fuel mode. In the present work, acetylene gas of 31/min were inducted and diesel was injected into the combustion chamber of a single cylinder air cooled diesel engine. It was observed that the higher calorific value of acetylene gas improves the brake thermal efficiency at full load conditions. The CO and HC emissions were higher at part load conditions as compared to conventional diesel. The Nox emission level was higher and smoke emission was lower during dual fuel mode under all operating conditions. It is concluded that dual fuel mode of acetylene gas and diesel improves the brake thermal efficiency and reduces smoke in diesel engine.

Keywords: acetylene gas, diesel engine, Nox emission, CO emission, HC emission

Procedia PDF Downloads 342
130 Experimental Investigation of Boundary Layer Instability and Transition on a Rotating Parabola in Axial Flow

Authors: Ali Kargar, Kamyar Mansour

Abstract:

In this paper the boundary layer instability and transition on a rotating parabola which is sheathed shape on a rotating 30 degrees total apex angle cone have been study by smoke visualization. The rotating cone especially 30 degrees total apex angle is a well-established subject in some previous novel works and also in our previous works. But in this paper a stabilizing effect is detected by the bluntness of nose and also surface curvature. A parabola model which is satisfying those conditions (sheathed parabola of the 30 degrees cone) has been built and studied in the wind tunnel. The results are shown that the boundary layer transition occurs at higher rotational Reynolds number in comparison by the cone. The results are shown in the visualization pictures and also are compared graphically.

Keywords: transitional Reynolds number, wind tunnel, smoke visualization, rotating parabola

Procedia PDF Downloads 393
129 Design, Construction, Validation And Use Of A Novel Portable Fire Effluent Sampling Analyser

Authors: Gabrielle Peck, Ryan Hayes

Abstract:

Current large scale fire tests focus on flammability and heat release measurements. Smoke toxicity isn’t considered despite it being a leading cause of death and injury in unwanted fires. A key reason could be that the practical difficulties associated with quantifying individual toxic components present in a fire effluent often require specialist equipment and expertise. Fire effluent contains a mixture of unreactive and reactive gases, water, organic vapours and particulate matter, which interact with each other. This interferes with the operation of the analytical instrumentation and must be removed without changing the concentration of the target analyte. To mitigate the need for expensive equipment and time-consuming analysis, a portable gas analysis system was designed, constructed and tested for use in large-scale fire tests as a simpler and more robust alternative to online FTIR measurements. The novel equipment aimed to be easily portable and able to run on battery or mains electricity; be able to be calibrated at the test site; be capable of quantifying CO, CO2, O2, HCN, HBr, HCl, NOx and SO2 accurately and reliably; be capable of independent data logging; be capable of automated switchover of 7 bubblers; be able to withstand fire effluents; be simple to operate; allow individual bubbler times to be pre-set; be capable of being controlled remotely. To test the analysers functionality, it was used alongside the ISO/TS 19700 Steady State Tube Furnace (SSTF). A series of tests were conducted to assess the validity of the box analyser measurements and the data logging abilities of the apparatus. PMMA and PA 6.6 were used to assess the validity of the box analyser measurements. The data obtained from the bench-scale assessments showed excellent agreement. Following this, the portable analyser was used to monitor gas concentrations during large-scale testing using the ISO 9705 room corner test. The analyser was set up, calibrated and set to record smoke toxicity measurements in the doorway of the test room. The analyser was successful in operating without manual interference and successfully recorded data for 12 of the 12 tests conducted in the ISO room tests. At the end of each test, the analyser created a data file (formatted as .csv) containing the measured gas concentrations throughout the test, which do not require specialist knowledge to interpret. This validated the portable analyser’s ability to monitor fire effluent without operator intervention on both a bench and large-scale. The portable analyser is a validated and significantly more practical alternative to FTIR, proven to work for large-scale fire testing for quantification of smoke toxicity. The analyser is a cheaper, more accessible option to assess smoke toxicity, mitigating the need for expensive equipment and specialist operators.

Keywords: smoke toxicity, large-scale tests, iso 9705, analyser, novel equipment

Procedia PDF Downloads 46
128 Investigation of Flow Effects of Soundwaves Incident on an Airfoil

Authors: Thirsa Sherry, Utkarsh Shrivastav, Kannan B. T., Iynthezhuton K.

Abstract:

The field of aerodynamics and aeroacoustics remains one of the most poignant and well-researched fields of today. The current paper aims to investigate the predominant problem concerning the effects of noise of varying frequencies and waveforms on airflow surrounding an airfoil. Using a single speaker beneath the airfoil at different positions, we wish to simulate the effects of sound directly impinging on an airfoil and study its direct effects on airflow. We wish to study the same using smoke visualization methods with incense as our smoke-generating material in a variable-speed subsonic wind tunnel. Using frequencies and wavelengths similar to those of common engine noise, we wish to simulate real-world conditions of engine noise interfering with airflow and document the arising trends. These results will allow us to look into the real-world effects of noise on airflow and how to minimize them and expand on the possible relation between waveforms and noise. The parameters used in the study include frequency, Reynolds number, waveforms, angle of attack, and the effects on airflow when varying these parameters.

Keywords: engine noise, aeroacoustics, acoustic excitation, low speed

Procedia PDF Downloads 68
127 Observational Study Reveals Inverse Relationship: Rising PM₂.₅ Concentrations Linked to Decreasing Muon Flux

Authors: Yashas Mattur, Jensen Coonradt

Abstract:

Muon flux, the rate of muons reaching Earth from the atmosphere, is impacted by various factors such as air pressure, temperature, and humidity. However, the influence of concentrations of PM₂.₅ (particulate matter with diameters 2.5 mm or smaller) on muon detection rates remains unexplored. During the summer of 2023, smoke from Canadian wildfires (containing significant amounts of particulate matter) blew over regions in the Northern US, introducing huge fluctuations in PM₂.₅ concentrations, thus inspiring our experiment to investigate the correlation of PM₂.₅ concentrations and muon rates. To investigate this correlation, muon collision rates were measured and analyzed alongside PM₂.₅ concentration data over the periods of both light and heavy smoke. Other confounding variables, including temperature, humidity, and atmospheric pressure, were also considered. The results reveal a statistically significant inverse correlation between muon flux and PM₂.₅ concentrations, indicating that particulate matter has an impact on the rate of muons reaching the earth’s surface.

Keywords: Muon Flux, atmospheric effects on muons, PM₂.₅, airborne particulate matter

Procedia PDF Downloads 42
126 Long-Range Transport of Biomass Burning Aerosols over South America: A Case Study in the 2019 Amazon Rainforest Wildfires Season

Authors: Angel Liduvino Vara-Vela, Dirceu Luis Herdies, Debora Souza Alvim, Eder Paulo Vendrasco, Silvio Nilo Figueroa, Jayant Pendharkar, Julio Pablo Reyes Fernandez

Abstract:

Biomass-burning episodes are quite common in the central Amazon rainforest and represent a dominant source of aerosols during the dry season, between August and October. The increase in the occurrence of fires in 2019 in the world’s largest biomes has captured the attention of the international community. In particular, a rare and extreme smoke-related event occurred in the afternoon of Monday, August 19, 2019, in the most populous city in the Western Hemisphere, the São Paulo Metropolitan Area (SPMA), located in southeastern Brazil. The sky over the SPMA suddenly blackened, with the day turning into night, as reported by several news media around the world. In order to clarify whether or not the smoke that plunged the SPMA into sudden darkness was related to wildfires in the Amazon rainforest region, a set of 48-hour simulations over South America were performed using the Weather Research and Forecasting with Chemistry (WRF-Chem) model at 20 km horizontal resolution, on a daily basis, during the period from August 16 to August 19, 2019. The model results were satisfactorily compared against satellite-based data products and in situ measurements collected from air quality monitoring sites. Although a very strong smoke transport coming from the Amazon rainforest was observed in the middle of the afternoon on August 19, its impact on air quality over the SPMA took place in upper levels far above the surface, where, conversely, low air pollutant concentrations were observed.

Keywords: Amazon rainforest, biomass burning aerosols, São Paulo metropolitan area, WRF-Chem model

Procedia PDF Downloads 108
125 Effect of Smoking on Tear Break-Up Time and Basal Tear Secretion

Authors: Kalsoom Rani

Abstract:

Tobacco contains nicotine, which causes addiction to many toxic chemicals. In the world, people consume it in the form of smoke, chew, and sniffing, smoke of it is composed of almost 7000 active chemicals, which are very harmful to human health as well as for eye health, inhalation of tobacco smoke and fumes can accelerate and cause many blinding eye diseases. Dry eye and smoking have not been covered extensively in researches; more studies are required to unveil the relationship between smoking and dry eye. This study was conducted to determine the quantity and quality of tears in smokers. 60 subjects participated in the study, which was divided into two groups on the basis of consumption of cigarettes per day with age matched non smokers of 15-50 years. All participants have gone through a study based questioner, eye examination, and diagnostic 'Dry Eye Tests' for evaporative tears evaluation and measurement of basal tear secretion. Subjects were included in the criteria of 10 cigarettes per day with a minimum duration of 1 year; passive smokers for control groups were excluded. The study was carried out in a Medina Teaching Hospital, Faisalabad, Pakistan, ophthalmology department for the duration of 8 months. Mean values for tear break up time (TBUT), was reported 10sec with SD of +3.74 in controlled group, 5sec with SD + 2.32 in smokers and 4sec SD +3.77 heavy smokers in right eye (RE) and left eye (LE) 10.35sec with SD of +3.88 in controlled 5sec with SD + 2.3 in smokers and much reduced TBUT in heavy smokers was 3.85sec SD+2.20. Smoking has a very strong association with TRUT with a significance of P=.00 both eyes. Mean Schirmer-I value of the subjects was reported 12.6mm with SD + 8.37 in RE and 12.59mm with SD + 8.96 LE. The mean Schirmer-II test value was reported in the right, and left eye with a mean value for control was 20.23mm with SD + 8.93, 20.75mm with SD + 8.84 respectively, and in Smokers 9.90mm with SD + 5.74, and 10.07mm with SD + 6.98, and in heavy smokers 7.7mm, SD + 3.22 and 6.9, SD + 3.50 mm, association with smoking showed p=.001 in RE and .003 in LE. Smoking has deteriorated effect on both evaporative tear and aqueous tear secretion and causing symptoms of dry eye burning, itching, redness, and watering with epithelial cell damage.

Keywords: tear break-up time, basal tear secretion, smokers, dry eye

Procedia PDF Downloads 99
124 The Association of Smoking and Body Mass Index with Acne Vulgaris in Adolescents and Young Adults

Authors: Almutazballlah Qablan, Jihan M. Muhaidat, Bana Abu Rajab

Abstract:

Background: Acne vulgaris is the most common skin condition that general practitioners and dermatologists encounter. It represents a chronic inflammatory disease affecting the pilosebaceous unit. Although acne vulgaris is not a life-threatening condition, it has a considerable psychological impact on the affected person. Acne patients have poor body image, low self-esteem, social isolation, and restricted activities. As part of the emotional impact, increased levels of anxiety, anger, depression, and frustration have also been observed in acne patients. (1) In this study, we want to assess the association between two modifiable risk factors; BMI and smoking, regarding acne vulgaris. Methods: A case-control study was conducted at King Abdullah University Hospital in Irbid, north Jordan in 2019/2020. A total number of 163 Acne cases were collected and interviewed by the author; on the other hand, there were 162 control cases. Anthropometric measures for Acne patients and control individuals were taken, and BMI was calculated. Both groups were asked about smoking habits. Data on subjects between 14 and 33 years of age were extracted. The characteristics of people who reported acne were compared with those with no acne using univariate and multivariate analysis. The Statistical Package for Social Sciences (SPSS) was relied on to analyze the collected data. The crosstabs methods (chi-square) and odd ratios were relied on to test the study hypothesis. Results: Cigarette smoking was highly associated with no-acne, with an odds ratio of 0.4 (95% CI: 0.2–0.9), P-value = 0.018. BMI and waterpipe smoking were not significantly associated with acne in the multivariate analysis. Conclusion: Cigarette smoking was found to be protective from Acne. No significant relation between BMI nor waterpipe smoking and the development of Acne Vulgaris.

Keywords: acne, BMI, smoking, case-control

Procedia PDF Downloads 62
123 Visualized Flow Patterns around and inside a Two-Sided Wind-Catcher in the Presence of Upstream Structures

Authors: M. Afshin, A. Sohankar, M. Dehghan Manshadi, M. R. Daneshgar, G. R. Dehghan Kamaragi

Abstract:

In this paper, the influence of an upstream structure on the flow pattern within and around the wind-catcher is experimentally investigated by smoke flow visualization techniques. Wind-catchers are an important part of natural ventilation in residential buildings or public places such as shopping centers, libraries, etc. Wind-catchers might be also used in places of high urban densities; hence their potential to provide natural ventilation in this case is dependent on the presence of upstream objects. In this study, the two-sided wind-catcher model was based on a real wind-catcher observed in the city of Yazd, Iran. The present study focuses on the flow patterns inside and outside the isolated two-sided wind-catcher, and on a two-sided wind-catcher in the presence of an upstream structure. The results show that the presence of an upstream structure influences the airflow pattern force and direction. Placing a high upstream object reverses the airflow direction inside the wind-catcher.

Keywords: natural ventilation, smoke flow visualization, two-sided wind-catcher, flow patterns

Procedia PDF Downloads 539
122 Particle Size Characteristics of Aerosol Jets Produced by A Low Powered E-Cigarette

Authors: Mohammad Shajid Rahman, Tarik Kaya, Edgar Matida

Abstract:

Electronic cigarettes, also known as e-cigarettes, may have become a tool to improve smoking cessation due to their ability to provide nicotine at a selected rate. Unlike traditional cigarettes, which produce toxic elements from tobacco combustion, e-cigarettes generate aerosols by heating a liquid solution (commonly a mixture of propylene glycol, vegetable glycerin, nicotine and some flavoring agents). However, caution still needs to be taken when using e-cigarettes due to the presence of addictive nicotine and some harmful substances produced from the heating process. Particle size distribution (PSD) and associated velocities generated by e-cigarettes have significant influence on aerosol deposition in different regions of human respiratory tracts. On another note, low actuation power is beneficial in aerosol generating devices since it exhibits a reduced emission of toxic chemicals. In case of e-cigarettes, lower heating powers can be considered as powers lower than 10 W compared to a wide range of powers (0.6 to 70.0 W) studied in literature. Due to the importance regarding inhalation risk reduction, deeper understanding of particle size characteristics of e-cigarettes demands thorough investigation. However, comprehensive study on PSD and velocities of e-cigarettes with a standard testing condition at relatively low heating powers is still lacking. The present study aims to measure particle number count and size distribution of undiluted aerosols of a latest fourth-generation e-cigarette at low powers, within 6.5 W using real-time particle counter (time-of-flight method). Also, temporal and spatial evolution of particle size and velocity distribution of aerosol jets are examined using phase Doppler anemometry (PDA) technique. To the authors’ best knowledge, application of PDA in e-cigarette aerosol measurement is rarely reported. In the present study, preliminary results about particle number count of undiluted aerosols measured by time-of-flight method depicted that an increase of heating power from 3.5 W to 6.5 W resulted in an enhanced asymmetricity in PSD, deviating from log-normal distribution. This can be considered as an artifact of rapid vaporization, condensation and coagulation processes on aerosols caused by higher heating power. A novel mathematical expression, combining exponential, Gaussian and polynomial (EGP) distributions, was proposed to describe asymmetric PSD successfully. The value of count median aerodynamic diameter and geometric standard deviation laid within a range of about 0.67 μm to 0.73 μm, and 1.32 to 1.43, respectively while the power varied from 3.5 W to 6.5 W. Laser Doppler velocimetry (LDV) and PDA measurement suggested a typical centerline streamwise mean velocity decay of aerosol jet along with a reduction of particle sizes. In the final submission, a thorough literature review, detailed description of experimental procedure and discussion of the results will be provided. Particle size and turbulent characteristics of aerosol jets will be further examined, analyzing arithmetic mean diameter, volumetric mean diameter, volume-based mean diameter, streamwise mean velocity and turbulence intensity. The present study has potential implications in PSD simulation and validation of aerosol dosimetry model, leading to improving related aerosol generating devices.

Keywords: E-cigarette aerosol, laser doppler velocimetry, particle size distribution, particle velocity, phase Doppler anemometry

Procedia PDF Downloads 14
121 Acne Vulgaris Association with Smoking and Body Mass Index in Jordanian Young Adults

Authors: Almutazballlah Bassam Qablan, Jihan M. Muhaidat, bana Abu Rajab

Abstract:

Background: Acne vulgaris is considered one of the most common skin conditions encountered by dermatologists. It is a chronic inflammation affecting the pilosebaceous unit. Although acne vulgaris is not fatal, it leads to permanent scarring and disfigurement, and even without scarring, it has a huge effect on patients, causing negative health outcomes. Acne vulgaris patients experience psychological, and emotional ramifications as those with chronic health problems; they feel depressed, angry, anxious, and confused. Although acne is a popular disease, many thoughts and myths are still discussed about its origins and triggering factors. These myths can make you feel guilt as if you were somehow responsible for your acne. In this case control study, we want to define the relationship between two modifiable risk factors ;BMI and smoking, with acne vulgaris. Methods: A case-control study was conducted at King Abdullah University Hospital in Ramtha, Jordan in 2019/2020. A total number of 325 participants between 14 and 33 years of age were interviewed by the authors; including 163 acne vulgaris cases and 162 controls without acne vulgaris. Anthropometric measures and smoking for Acne patients and control participants were the independent variables used to assess acne. Univariate and multivariate analysis were used to compare the characteristics of people who reported acne with those with no acne. The collected data analyzed by using the Statistical Package for Social Sciences (SPSS). Results: Cigarette smoking was highly associated with controls; odds ratio 0.4 (95% CI: 0.2–0.9) , P-value = 0.018. BMI and waterpipe smoking were statistically insignificant with acne in the multivariate analysis. Conclusion: We found that cigarette smoking was protective against Acne. There was a statistically insignificant relation between BMI, waterpipe smoking and the development of Acne Vulgaris.

Keywords: acne, adolescents, BMI, smoking, case-control, risk factors

Procedia PDF Downloads 62
120 The Impact of Informal Care on Health Behavior among Older People with Chronic Diseases: A Study in China Using Propensity Score Matching

Authors: Hong Wu, Naiji Lu

Abstract:

Improvement of health behavior among people with chronic diseases is vital for increasing longevity and enhancing quality of life. This paper researched the causal effects of informal care on the compliance with doctor’s health advices – smoking control, dietetic regulation, weight control and keep exercising – among older people with chronic diseases in China, which is facing the challenge of aging. We addressed the selection bias by using propensity score matching in the estimation process. We used the 2011-2012 national baseline data of the China Health and Retirement Longitudinal Study. Our results showed informal care can help improve health behavior of older people. First, informal care improved the compliance of smoking controls: whether smoke, frequency of smoking, and the time lag between wake up and the first cigarette was all lower for these older people with informal care; Second, for dietetic regulation, older people with informal care had more meals every day than older people without informal care; Third, three variables: BMI, whether gain weight and whether lose weight were used to measure the outcome of weight control. There were no significant difference between group with informal care and that without for BMI and the possibility of losing weight. Older people with informal care had lower possibility of gain weight than that without; Last, for the advice of keeping exercising, informal care increased the probability of walking exercise, however, the difference between groups for moderate and vigorous exercise were not significant. Our results indicate policy makers who aim to decrease accidents should take informal care to elders into account and provide an appropriate policy to meet the demand of informal care. Our birth policy and postponed retirement policy may decrease the informal caregiving hours, so adjustments of these policies are important and urgent to meet the current situation of aged tendency of population. In addition, government could give more support to develop organizations to provide formal care, such as nursing home. We infer that formal care is also useful for health behavior improvements.

Keywords: chronic diseases, compliance, CHARLS, health advice, informal care, older people, propensity score matching

Procedia PDF Downloads 377
119 Effect of Injection Pressure and Fuel Injection Timing on Emission and Performance Characteristics of Karanja Biodiesel and its Blends in CI Engine

Authors: Mohan H., C. Elajchet Senni

Abstract:

In the present of high energy consumption in every sphere of life, renewable energy sources are emerging as alternative to conventional fuels for energy security, mitigating green house gas emission and climate change. There has been a world wide interest in searching for alternatives to petroleum derived fuels due to their depletion as well as due to the concern for the environment. Vegetable oils have capability to solve this problem because they are renewable and lead to reduction in environmental pollution. But high smoke emission and lower thermal efficiency are the main problems associated with the use of neat vegetable oils in diesel engines. In the present work, performance, combustion and emission characteristics of CI engine fuelled with 20% by vol. methyl esters mixed with Karanja seed Oil, and Fuel injection pressures of 200 bar and 240 bar, injection timings (21°,23° and 25° BTDC) and Proportion B20 diesel respectively. Vegetable oils have capability to solve this problem because they are renewable and lead to reduction in environmental pollution. But, high smoke emission and lower thermal efficiency are the main problems associated with the use of neat vegetable oils in diesel engines. In the present work, performance, combustion and emission characteristics of CI engine fuelled with 20% by vol. methyl esters mixed with Karanja seed Oil, and Fuel injection pressures of 200 bar and 240 bar ,Injection timings (21°,23° and 25° BTDC) and Proportion B20 diesel respectively. Various performance, combustion and emission characteristics such as thermal efficiency, and brake specific fuel consumption, maximum cylinder pressure, instantaneous heat release, cumulative heat release with respect to crank angle, ignition lag, combustion duration, HC, NOx, CO, exhaust temperature and smoke intensity were measured.

Keywords: karanja oil, injection pressure, injection timing, karanja oil methyl ester

Procedia PDF Downloads 262
118 A Smart Monitoring System for Preventing Gas Risks in Indoor

Authors: Gyoutae Park, Geunjun Lyu, Yeonjae Lee, Jaheon Gu, Sanguk Ahn, Hiesik Kim

Abstract:

In this paper, we propose a system for preventing gas risks through the use of wireless communication modules and intelligent gas safety appliances. Our system configuration consists of an automatic extinguishing system, detectors, a wall-pad, and a microcomputer controlled micom gas meter to monitor gas flow and pressure as well as the occurrence of earthquakes. The automatic fire extinguishing system checks for both combustible gaseous leaks and monitors the environmental temperature, while the detector array measures smoke and CO gas concentrations. Depending on detected conditions, the micom gas meter cuts off an inner valve and generates a warning, the automatic fire-extinguishing system cuts off an external valve and sprays extinguishing materials, or the sensors generate signals and take further action when smoke or CO are detected. Information on intelligent measures taken by the gas safety appliances and sensors are transmitted to the wall-pad, which in turn relays this as real time data to a server that can be monitored via an external network (BcN) connection to a web or mobile application for the management of gas safety. To validate this smart-home gas management system, we field-tested its suitability for use in Korean apartments under several scenarios.

Keywords: gas sensor, leak, gas safety, gas meter, gas risk, wireless communication

Procedia PDF Downloads 396