5538 Effects of Hypolipidemic Agents in Aminoglycoside-Induced Experimental Nephrotoxicity in Rats: Biochemical and Histopathological Evidence

Authors: Balakumar Pitchai, Xiang Llan Ang, Sunil Prajapati, Varatharajan Rajavel, Sundram Karupiah, Mohd Baidi Bahari

Abstract:

The study examined the pretreatment and post-treatment effects of low-doses of fenofibrate and rosuvastatin in gentamicin-induced acute nephrotoxicity in rats. Gentamicin (100 mg/kg/day, i.p.) was administered to rats for 8 days. In the pretreatment protocol, low-dose fenofibrate (30 mg/kg/day, p.o.) or low-dose rosuvastatin (2 mg/kg/day, p.o.) treatments were started a day before the administration of gentamicin and continued for 8 days. In the post-treatment protocol, rats administered gentamicin were treated with low-dose fenofibrate (30 mg/kg/day, p.o.) or low-dose rosuvastatin (2 mg/kg/day, p.o.) for 6 days after the completion of 8 days protocol of gentamicin administration. Gentamicin-associated acute nephrotoxicity in rats was assessed in terms of biochemical analysis and renal histopathological studies. Gentamicin-administered rats showed marked renal functional changes as assessed in terms of a significant increase in serum creatinine and urea levels as compared to normal rats. The renal dysfunction noted in gentamicin administered rats was accompanied with elevated serum uric acid level as compared to normal rats while there was no significant change in lipid profile. Low-dose fenofibrate pretreatment in gentamicin-administered rats afforded a significant renal functional improvements and renoprotection while its post-treatment showed no significant renoprotection. On the other hand, pretreatment with low-dose rosuvastatin partially reduced gentamicin-induced increase in serum creatinine level, but its post-treatment did not afford renal functional improvements in gentamicin-administered rats. However, all pre and post-treatments with low-doses of fenofibrate or rosuvastatin significantly reduced the elevated serum uric acid concentration in gentamicin-administered rats. Renal histopathological analysis showed a discernible incidence of acute tubular necrosis in gentamicin-administered rats which were markedly reduced by low-dose fenofibrate or low-dose rosuvastatin pretreatments; but, not by their post-treatments. In conclusion, low-dose fenofibrate pretreatment considerably prevented gentamicin-induced acute tubular necrosis and renal functional abnormalities in rats while its post-treatment resulted in no significant renoprotective action. In spite of effective prevention of gentamicin-induced acute tubular necrosis, the pretreatment with low-dose rosuvastatin had only a partial and fractional protection on renal functional abnormalities. The post-treatment with low-dose rosuvastatin was ineffective in affording a renoprotection in gentamicin-administered rats.

Keywords: gentamicin-nephrotoxicity, low-dose fenofibrate, low-dose rosuvastatin, renoprotection

Procedia PDF Downloads 191
5537 Measurement of IMRT Dose Distribution in Rando Head and Neck Phantom using EBT3 Film

Authors: Pegah Safavi, Mehdi Zehtabian, Mohammad Amin Mosleh-Shirazi

Abstract:

Cancer is one of the leading causes of death in the world. Radiation therapy is one of the main choices for cancer treatment. Intensity-modulated radiation therapy is a new type of radiation therapy technique available for vital structures such as the parathyroid glands. It is very important to check the accuracy of the delivered IMRT treatment because any mistake may lead to more complications for the patient. This paper describes an experiment to determine the accuracy of a dose measured by EBT3 film. To test this method, the EBT3 film on the head and neck of the Rando phantom was irradiated by an IMRT device and the irradiation was repeated twice. Finally, the dose designed by the irradiation system was compared with the dose measured by the EBT3 film. Using this criterion, the accuracy of the EBT3 film was evaluated. When using this criterion, a 95% agreement was reached between the planned treatment and the measured values.

Keywords: EBT3, phantom, accuracy, cancer, IMRT

Procedia PDF Downloads 139
5536 Debating the Role of Patriarchy in the Incidence of Gender-Based Violence in Jordan: Systematic Review of the Literature

Authors: Nour Daoud

Abstract:

Patriarchy continues to thrive in Jordan where male-controlled values are still entrenched in a society that is suffering from upsetting percentages of Gender-based Violence (GBV). This paper is a systematic review of the literature with an attempt to evaluate and interpret all available research evidence relevant to determining the extent to which patriarchy contributes to the occurrence, re-occurrence, and continuation of GBV in Jordan. Twenty-one (21) full-text articles were selected for the in-depth review due to meeting the established criteria for inclusion. 81 percent of articles included primary data while 19 percent included secondary data. Analysis of data was based on a specific extraction form that was developed using the ‘Excel’ to respond to the main goal of the paper. Interpretation of data was in light of the theorization of different feminism schools on the relationship between patriarchy and gender-based violence. Findings show that 33 percent of the selected articles affirm that the patriarchal standpoint best explains the role of patriarchy in the incidence of gender-based violence in Jordan under its three main themes (Honor-based Violence, Intimate Partner Violence and Street Harassment). Apart from the limited number of articles that were found debating this argument and the low percentage of articles that acknowledged the role of patriarchy in the incidence of gender-based violence in Jordan, this paper breaks the ice to implement future empirical studies on this subject. Also, it is an invitation for all Jordanian women to unite their efforts in order to eradicate all forms of victimization against them.

Keywords: honor-based violence, intimate partner violence, middle-east, street harassment

Procedia PDF Downloads 213
5535 Influence of Channel Depth on the Performance of Wavy Fin Absorber Solar Air Heater

Authors: Abhishek Priyam, Prabha Chand

Abstract:

Channel depth is an important design parameter to be fixed in designing a solar air heater. In this paper, a mathematical model has been developed to study the influence of channel duct on the thermal performance of solar air heaters. The channel depth has been varied from 1.5 cm to 3.5 cm for the mass flow range 0.01 to 0.11 kg/s. Based on first law of thermodynamics, the channel depth of 1.5 cm shows better thermal performance for all the mass flow range. Also, better thermohydraulic performance has been found up to 0.05 kg/s, and beyond this, thermohydraulic efficiency starts decreasing. It has been seen that, with the increase in the mass flow rate, the difference between thermal and thermohydraulic efficiency increases because of the increase in pressure drop. At lower mass flow rate, 0.01 kg/s, the thermal and thermohydraulic efficiencies for respective channel depth remain the same.

Keywords: channel depth, thermal efficiency, wavy fin, thermohydraulic efficiency

Procedia PDF Downloads 363
5534 Development of a Laboratory Laser-Produced Plasma “Water Window” X-Ray Source for Radiobiology Experiments

Authors: Daniel Adjei, Mesfin Getachew Ayele, Przemyslaw Wachulak, Andrzej Bartnik, Luděk Vyšín, Henryk Fiedorowicz, Inam Ul Ahad, Lukasz Wegrzynski, Anna Wiechecka, Janusz Lekki, Wojciech M. Kwiatek

Abstract:

Laser produced plasma light sources, emitting high intensity pulses of X-rays, delivering high doses are useful to understand the mechanisms of high dose effects on biological samples. In this study, a desk-top laser plasma soft X-ray source, developed for radio biology research, is presented. The source is based on a double-stream gas puff target, irradiated with a commercial Nd:YAG laser (EKSPLA), which generates laser pulses of 4 ns time duration and energy up to 800 mJ at 10 Hz repetition rate. The source has been optimized for maximum emission in the “water window” wavelength range from 2.3 nm to 4.4 nm by using pure gas (argon, nitrogen and krypton) and spectral filtering. Results of the source characterization measurements and dosimetry of the produced soft X-ray radiation are shown and discussed. The high brightness of the laser produced plasma soft X-ray source and the low penetration depth of the produced X-ray radiation in biological specimen allows a high dose rate to be delivered to the specimen of over 28 Gy/shot; and 280 Gy/s at the maximum repetition rate of the laser system. The source has a unique capability for irradiation of cells with high pulse dose both in vacuum and He-environment. Demonstration of the source to induce DNA double- and single strand breaks will be discussed.

Keywords: laser produced plasma, soft X-rays, radio biology experiments, dosimetry

Procedia PDF Downloads 577
5533 Variation with Depth of Physico-Chemical, Mineralogical and Physical Properties of Overburden over Gneiss Basement Complex in Minna Metropolis, North Central Nigeria

Authors: M. M. Alhaji, M. Alhassan, A. M. Yahaya

Abstract:

Soil engineers pay very little or no attention to variation in the mineralogical and consequently, the geotechnical properties of overburden with depth on basement complexes, a situation which can lead to sudden failure of civil engineering structures. Soil samples collected at depths ranging from 0.5m to 4.0m at 0.5m intervals, from a trial pit dogged manually to depth of 4.0m on an overburden over gneiss basement complex, was evaluated for physico-chemical, mineralogical and physical properties. This is to determine the variation of these properties with depth within the profile of the strata. Results showed that sodium amphibolite and feldspar, which are both primary minerals dominate the overall profile of the overburden. Carbon which dominates the lower profile of the strata was observed to alter to gregorite at upper section of the profile. Organic matter contents and cation exchange capacity reduces with increase in depth while lost on ignition and pH were relatively constant with depth. The index properties, as well as natural moisture contents, increases from 0.5m to between 1.0m to 1.5m depth after which the values reduced to constant values at 3.0m depth. The grain size analysis shows high composition of sand sized particles with silts of low to non-plasticity. The maximum dry density (MDD) values are generally relatively high and increases from 2.262g/cm³ at 0.5m depth to 2.410g/cm³ at 4.0m depth while the optimum moisture content (OMC) reduced from 9.8% at 0.5m depth to 6.7% at 4.0m depth.

Keywords: Gneiss basement complex, mineralogical properties, North Central Nigeria, physico-chemical properties, physical properties, overburden soil

Procedia PDF Downloads 137
5532 Difference between 'HDR Ir-192 and Co-60 Sources' for High Dose Rate Brachytherapy Machine

Authors: Md Serajul Islam

Abstract:

High Dose Rate (HDR) Brachytherapy is used for cancer patients. In our country’s prospect, we are using only cervices and breast cancer treatment by using HDR. The air kerma rate in air at a reference distance of less than a meter from the source is the recommended quantity for the specification of gamma ray source Ir-192 in brachytherapy. The absorbed dose for the patients is directly proportional to the air kerma rate. Therefore the air kerma rate should be determined before the first use of the source on patients by qualified medical physicist who is independent from the source manufacturer. The air kerma rate will then be applied in the calculation of the dose delivered to patients in their planning systems. In practice, high dose rate (HDR) Ir-192 afterloader machines are mostly used in brachytherapy treatment. Currently, HDR-Co-60 increasingly comes into operation too. The essential advantage of the use of Co-60 sources is its longer half-life compared to Ir-192. The use of HDRCo-60 afterloading machines is also quite interesting for developing countries. This work describes the dosimetry at HDR afterloading machines according to the protocols IAEA-TECDOC-1274 (2002) with the nuclides Ir-192 and Co-60. We have used 3 different measurement methods (with a ring chamber, with a solid phantom and in free air and with a well chamber) in dependence of each of the protocols. We have shown that the standard deviations of the measured air kerma rate for the Co-60 source are generally larger than those of the Ir-192 source. The measurements with the well chamber had the lowest deviation from the certificate value. In all protocols and methods, the deviations stood for both nuclides by a maximum of about 1% for Ir-192 and 2.5% for Co-60-Sources respectively.

Keywords: Ir-192 source, cancer, patients, cheap treatment cost

Procedia PDF Downloads 224
5531 Prevalence and Antibiotic Resistance Patterns of Salmonella from Retail Dressed Chickens (Gallus gallus domesticus) in Wet Markets of Cavite, Philippines

Authors: Chester Joshua V. Saldana, Yolanda A. Ilagan

Abstract:

This study determines the prevalence of Salmonella from retail dressed chickens using chicken wings as samples in five wet city markets of Cavite, Philippines, compares the prevalence among the markets' samples and determines the serotypes and antibiotic resistance pattern of Salmonella isolates. The overall prevalence of Salmonella in five wet markets in Cavite was 13.33 percent. Samples from Bacoor yielded the highest prevalence rate of 26.6 percent, followed by Imus (23.3%), Dasmarinas (11.6%), Trece Martires (3.3%) and Tagaytay (1.6%). Seven serotypes (serogroups B, C2, C3, D1 and E1) were isolated which include Salmonella weltevreden, S. derby, S. newport, S. albany, S. typhimurium, and S. enteritidis. Salmonella weltevreden was the predominant serotype while S. typhi and S. albany were the least common. Among the 15 antibiotics tested, resistance to ampicillin, tetracycline, and cephalexin was exhibited by all the isolates while 5 percent showed resistance to gentamicin, 2.5 percent to streptomycin and 12.5 percent to nitrofurantoin. One isolate was resistant to four antibiotics whereas most isolates of S. enteritidis were resistant to 2 to 5 antibiotics. Four resistance patterns were recorded. This study revealed the emergence of multidrug-resistant Salmonella serotypes from chicken meat in Cavite, Philippines.

Keywords: antibiotics, dressed chickens, resistance patterns, Salmonella serovars

Procedia PDF Downloads 316
5530 Calculation of Organ Dose for Adult and Pediatric Patients Undergoing Computed Tomography Examinations: A Software Comparison

Authors: Aya Al Masri, Naima Oubenali, Safoin Aktaou, Thibault Julien, Malorie Martin, Fouad Maaloul

Abstract:

Introduction: The increased number of performed 'Computed Tomography (CT)' examinations raise public concerns regarding associated stochastic risk to patients. In its Publication 102, the ‘International Commission on Radiological Protection (ICRP)’ emphasized the importance of managing patient dose, particularly from repeated or multiple examinations. We developed a Dose Archiving and Communication System that gives multiple dose indexes (organ dose, effective dose, and skin-dose mapping) for patients undergoing radiological imaging exams. The aim of this study is to compare the organ dose values given by our software for patients undergoing CT exams with those of another software named "VirtualDose". Materials and methods: Our software uses Monte Carlo simulations to calculate organ doses for patients undergoing computed tomography examinations. The general calculation principle consists to simulate: (1) the scanner machine with all its technical specifications and associated irradiation cases (kVp, field collimation, mAs, pitch ...) (2) detailed geometric and compositional information of dozens of well identified organs of computational hybrid phantoms that contain the necessary anatomical data. The mass as well as the elemental composition of the tissues and organs that constitute our phantoms correspond to the recommendations of the international organizations (namely the ICRP and the ICRU). Their body dimensions correspond to reference data developed in the United States. Simulated data was verified by clinical measurement. To perform the comparison, 270 adult patients and 150 pediatric patients were used, whose data corresponds to exams carried out in France hospital centers. The comparison dataset of adult patients includes adult males and females for three different scanner machines and three different acquisition protocols (Head, Chest, and Chest-Abdomen-Pelvis). The comparison sample of pediatric patients includes the exams of thirty patients for each of the following age groups: new born, 1-2 years, 3-7 years, 8-12 years, and 13-16 years. The comparison for pediatric patients were performed on the “Head” protocol. The percentage of the dose difference were calculated for organs receiving a significant dose according to the acquisition protocol (80% of the maximal dose). Results: Adult patients: for organs that are completely covered by the scan range, the maximum percentage of dose difference between the two software is 27 %. However, there are three organs situated at the edges of the scan range that show a slightly higher dose difference. Pediatric patients: the percentage of dose difference between the two software does not exceed 30%. These dose differences may be due to the use of two different generations of hybrid phantoms by the two software. Conclusion: This study shows that our software provides a reliable dosimetric information for patients undergoing Computed Tomography exams.

Keywords: adult and pediatric patients, computed tomography, organ dose calculation, software comparison

Procedia PDF Downloads 144
5529 Estimation of Adult Patient Doses for Chest X-Ray Diagnostic Examinations in a Tertiary Institution Health Centre

Authors: G. E. Okungbowa, H. O. Adams, S. E. Eze

Abstract:

This study is on the estimation of adult patient doses for Chest X-ray diagnostic examinations of new admitted undergraduate students attending a tertiary institution health centre as part of their routine clearance and check up on admitted into the institution. A total of 531 newly admitted undergraduate students were recruited for this survey in the first quarter of 2016 (January to March, 2016). CALDOSE_X 5.0 software was used to compute the Entrance Surface Dose (ESD) and Effective Dose (ED); while the Statistical Package for Social Sciences (SPSS) version 21.0 was used to carry out the statistical analyses. The basic patients' data and exposure parameters required for the software are age, sex, examination type, projection posture, tube potential and current-time product. The mean Entrance Surface Dose and Effective Doses of the undergraduate students were calculated using the software, and the values were compared with existing literature and internationally established diagnostic reference levels. The mean ESD calculated is 0.29 mGy, and the mean effective dose is 0.04 mSv. The values of ESD and ED obtained are below the internationally established diagnostic reference levels, which could be attributed to good radiographic techniques employed during the chest X-ray procedure for these students.

Keywords: x-ray, dose, examination, chest

Procedia PDF Downloads 169
5528 Evaluation of the Analgesic Activity of Defatted Methanol Extract of Capparis spinosa L. Root Barks

Authors: Asma Meddour, Mouloud Yahia, Afaf Benhouda, Souhila Benbia, Hachani Khadhraoui

Abstract:

Peripheral analgesic activity of defatted methanol extract of root barks of Capparis spinosa was tested orally at the dose of 100 and 200 mg/kg against pain induced by acetic acid in rats. The dose of 200 mg/kg presents significant analgesic effect with a percentage of inhibition of torsions of 88.51% compared to the positive control which is the acetylsalicylic acid which represents a percentage of inhibition of 92.55%. The dose of 100 mg/kg presents a percentage of inhibition of 81.68%.

Keywords: peripheral analgesic activity, Capparis spinosa, percentage of inhibition of torsions, chemical sciences

Procedia PDF Downloads 280
5527 In vivo Anticandida Activity of Three Traditionally Used Medicinal Plants in East Africa

Authors: Daniel P. Kisangau, Ken M. Hosea, Herbert V. M. Lyaruu, Cosam C. Josep, Zakaria H. Mbwambo, Pax J. Masimba

Abstract:

Crude extracts of Dracaena steudneri bark (DSB), Sapium ellipticum bark (SEB) and Capparis erythrocarpos root (CER) were investigated for their antifungal activity in immunocompromised mice infected with Candida albicans in an in vivo mice infection model. The results revealed a substantial dose dependency in all treatments given, with mice survival to the end of the experiment correlating well to the dose levels. At a dose of 400 mg/kg, C. erythrocarpos was the most effective with mice survival of 60% and organ burden clearance ranging from 64.0%-99.9% (P<0.0001) in all treatments. At the same dose, the least effective plant was S. ellipticum which had a mice survival of 20% and organ burden clearance ranging from 78.0%-96.6 (P>0.05). Mice survival for D. steudneri was 30% with organ burden clearance ranging from 89.0%-99.9% (P<0.05). All mice receiving no active treatment died before ten days post infection. In all treatment groups, there was a steady decline in mean weights of mice immediately after immunosuppression followed by gradual recovery in some cases which appeared to be dose dependent a few days post infection. Thus, extracts of D. steudneri and C. erythrocarpos portrayed the most significant potential as sources of antifungal drugs.

Keywords: antifungal activity, medicinal plants, candida albicans, East Africa

Procedia PDF Downloads 496
5526 Analysis of Teachers' Self Efficacy in Terms of Emotional Intelligence

Authors: Ercan Yilmaz, Ali Murat Sünbül

Abstract:

The aim of the study is to investigate teachers’ self-efficacy with regards to their emotional intelligence. The relational model was used in the study. The participant of the study included 194 teachers from secondary schools in Konya, Turkey. In order to assess teachers’ emotional intelligence, “Trait Emotional Intelligence Questionnaire-short Form was implemented. For teachers’ self-efficacy, “Teachers’ Sense of Self-Efficacy Scale” was used. As a result of the study, a significant relationship is available between teachers’ sense of self-efficacy and their emotional intelligence. Teachers’ emotional intelligence enucleates approximate eighteen percent of the variable in dimension named teachers’ self-efficacy for the students’ involvement. About nineteen percent of the variable in dimension “self-efficacy for teaching strategies is represented through emotional intelligence. Teachers’ emotional intelligence demonstrates about seventeen percent of variable aimed at classroom management.

Keywords: teachers, self-efficacy, emotional intelligence, education

Procedia PDF Downloads 438
5525 Absorbed Dose Estimation of 177Lu-DOTATOC in Adenocarcinoma Breast Cancer Bearing Mice

Authors: S. Zolghadri, M. Mousavi-Daramoroudi, H. Yousefnia, F. Abbasi-Davani

Abstract:

In this study, the absorbed dose of human organs after injection of 177Lu-DOTATOC was studied based on the biodistribution of the complex in adenocarcinoma breast cancer bearing mice. For this purpose, the biodistribution of the radiolabelled complex was studied and compartmental modeling was applied to calculate the absorbed dose with high precision. As expected, 177Lu-DOTATOC illustrated a notable specific uptake in tumor and pancreas, organs with high level of somatostatin receptor on their surface and the effectiveness of the radio-conjugate for targeting of the breast adenocarcinoma tumors was indicated. The elicited results of modeling were the exponential equations, and those are utilized for obtaining the cumulated activity data by taking their integral. The results also exemplified that non-target absorbed-doses such as the liver, spleen and pancreas were approximately 0.008, 0.004, and 0.039, respectively. While these values were so much lower than target (tumor) absorbed-dose, it seems due to this low toxicity, this complex is a good agent for therapy.

Keywords: ¹⁷⁷Lu, breast cancer, compartmental modeling, dosimetry

Procedia PDF Downloads 136
5524 Genotoxicity Induced by Nanoparticles on Human Lymphoblast Cells (TK6)

Authors: Piyaporn Buaklang, Narisa Kengtrong Bordeerat

Abstract:

The use of nanoparticles is increasing worldwide and there are many nanotech-based daily products available in the market. The toxicity of nanoparticles results from their extremely small size which can be transported easily into the blood stream and other organs. We aimed to study the genotoxicity of two nanoparticles, Titanium dioxide (TiO2-NPs) and Zinc oxide (ZnO-NPs), in TK6 cells by micronucleus assay. The cells were tested at 8, 24, and 48 hours after exposed to 0.10, 0.25, 0.50 and 1.00 µg/mL of TiO2-NPs particles size < 25 nm and < 100 nm and to ZnO-NPs at 1, 10, 50, and 100 µg/mL, particles size < 50 nm and < 100 nm. At 24 hours of incubation transmission electron microscope (TEM) revealed that the nanoparticles TiO2-NPs at 1.00 µg/mL and ZnO-NPs at 10 µg/mL were able to be taken into the cells and induced the production of increasing amount of micronucleus in dose-dependent manner. The effect of the two nanoparticles on chromosome aberration indicated that TiO2-NPs and ZnO-NPs are genotoxic. In addition, the toxicity of TiO2-NPs was found to be 10 times more toxic than ZnO-NPs after 24 hours exposure. Analysis showed that the TiO2-NPs induced formation of micronucleus was both time and dose dependent, whereas the genotoxicity of ZnO-NPs was only dose dependent. In conclusion, TiO2-NPs and ZnO-NPs were able to transport through the cells membrane and directly genotoxic to TK6 cells in dose-dependent manner.

Keywords: nanoparticles, genotoxicity, human lymphoblast cells (TK6), micronucleus

Procedia PDF Downloads 292
5523 Impact of the Government Ghana Block Farm Program on Rural Households in Northern Ghana

Authors: Antwi Kwaku Dei, Lyford Conrad Power

Abstract:

This paper investigates the outcome of participating in the government of Ghana block farm program on rural households’ farm productivity, income, food security and nutritional status in Northern Ghana using cross-sectional data. Data analysis was done using the Instrumental Variable and the Heckman Selection Bias procedures. Our analysis indicates that participation in the block farm program significantly increased directly the productivity of maize, rice, and soybean by 21.3 percent, 15.8 percent, and 12.3 percent respectively. Also, the program participation was found to increase households’ farm income by 20 percent in northern Ghana. Furthermore, program participation was found to improve household food security and nutrition by 19 percent and 14 percent respectively through income effect. Based on the benefit-cost ratio of 1.59 the results from the study recommends that the program is expanded to other communities in the northern region. Further analysis indicates that rural households’ decision to participate in food security intervention programs is significantly influenced by factors including the gender of the household head, the age of the household head, and household size. Results of the study further show that gender of household head, household size, household monthly income, household assets, women educational status, the age of women, marital status of women, are significant determinants of food security and nutrition status in Northern Ghana.

Keywords: block farm program, farm productivity, , household food security, Northern Ghana

Procedia PDF Downloads 267
5522 A Study of the Tactile Codification on the Philippine Banknote: Redesigning for the Blind

Authors: Ace Mari S. Simbajon, Rhaella J. Ybañez, Mae G. Nadela, Cherry E. Sagun, Nera Mae A. Puyo

Abstract:

This study determined the usability of the Philippine banknotes. An experimental design was used in the study involving twenty (n=20) randomly selected blind participants. The three aspects of usability were measured: effectiveness, efficiency, and satisfaction. It was found out that the effectiveness rate of the current Philippine Banknotes ranges from 20 percent to 35 percent which means it is not effective basing from Cauro’s threshold of average effectiveness rate which is 78 percent. Its efficiency rate is ranging from 18.06 to 26.22 seconds per denomination. The average satisfaction rate is 1.45 which means the blind are very dissatisfied. These results were used as a guide in making the proposed tactile codification using embossed dots or embossed lines. A round of simulation was conducted with the blind to assess the usability of the two proposals. Results were then statistically treated using t-test. Results show statistically significant difference between the usability of the current banknotes versus the proposed designs. Moreover, it was found out that the use of embossed dots is more effective, more efficient, and more satisfying than the embossed lines with an effectiveness rate ranging from 90 percent to 100 percent, efficiency rate ranging from 6.73 seconds to 12.99 seconds, and satisfaction rate of 3.4 which means the blind are very satisfied.

Keywords: blind, Philippine banknotes, tactile codification, usability

Procedia PDF Downloads 275
5521 Dosimetric Application of α-Al2O3:C for Food Irradiation Using TA-OSL

Authors: A. Soni, D. R. Mishra, D. K. Koul

Abstract:

α-Al2O3:C has been reported to have deeper traps at 600°C and 900°C respectively. These traps have been reported to accessed at relatively earlier temperatures (122 and 322 °C respectively) using thermally assisted OSL (TA-OSL). In this work, the dose response α-Al2O3:C was studied in the dose range of 10Gy to 10kGy for its application in food irradiation in low ( upto 1kGy) and medium(1 to 10kGy) dose range. The TOL (Thermo-optically stimulated luminescence) measurements were carried out on RisØ TL/OSL, TL-DA-15 system having a blue light-emitting diodes (λ=470 ±30nm) stimulation source with power level set at the 90% of the maximum stimulation intensity for the blue LEDs (40 mW/cm2). The observations were carried on commercial α-Al2O3:C phosphor. The TOL experiments were carried out with number of active channel (300) and inactive channel (1). Using these settings, the sample is subjected to linear thermal heating and constant optical stimulation. The detection filter used in all observations was a Hoya U-340 (Ip ~ 340 nm, FWHM ~ 80 nm). Irradiation of the samples was carried out using a 90Sr/90Y β-source housed in the system. A heating rate of 2 °C/s was preferred in TL measurements so as to reduce the temperature lag between the heater plate and the samples. To study the dose response of deep traps of α-Al2O3:C, samples were irradiated with various dose ranging from 10 Gy to 10 kGy. For each set of dose, three samples were irradiated. In order to record the TA-OSL, initially TL was recorded up to a temperature of 400°C, to deplete the signal due to 185°C main dosimetry TL peak in α-Al2O3:C, which is also associated with the basic OSL traps. After taking TL readout, the sample was subsequently subjected to TOL measurement. As a result, two well-defined TA-OSL peaks at 121°C and at 232°C occur in time as well as temperature domain which are different from the main dosimetric TL peak which occurs at ~ 185°C. The linearity of the integrated TOL signal has been measured as a function of absorbed dose and found to be linear upto 10kGy. Thus, it can be used for low and intermediate dose range of for its application in food irradiation. The deep energy level defects of α-Al2O3:C phosphor can be accessed using TOL section of RisØ reader system.

Keywords: α-Al2O3:C, deep traps, food irradiation, TA-OSL

Procedia PDF Downloads 286
5520 An Adaptive Neuro-Fuzzy Inference System (ANFIS) Modelling of Bleeding

Authors: Seyed Abbas Tabatabaei, Fereydoon Moghadas Nejad, Mohammad Saed

Abstract:

The bleeding prediction of the asphalt is one of the most complex subjects in the pavement engineering. In this paper, an Adaptive Neuro Fuzzy Inference System (ANFIS) is used for modeling the effect of important parameters on bleeding is trained and tested with the experimental results. bleeding index based on the asphalt film thickness differential as target parameter,asphalt content, temperature depth of two centemeter, heavy traffic, dust to effective binder, Marshall strength, passing 3/4 sieves, passing 3/8 sieves,passing 3/16 sieves, passing NO8, passing NO50, passing NO100, passing NO200 as input parameters. Then, we randomly divided empirical data into train and test sections in order to accomplish modeling. We instructed ANFIS network by 72 percent of empirical data. 28 percent of primary data which had been considered for testing the approprativity of the modeling were entered into ANFIS model. Results were compared by two statistical criterions (R2, RMSE) with empirical ones. Considering the results, it is obvious that our proposed modeling by ANFIS is efficient and valid and it can also be promoted to more general states.

Keywords: bleeding, asphalt film thickness differential, Anfis Modeling

Procedia PDF Downloads 260
5519 Optimizing Exposure Parameters in Digital Mammography: A Study in Morocco

Authors: Talbi Mohammed, Oustous Aziz, Ben Messaoud Mounir, Sebihi Rajaa, Khalis Mohammed

Abstract:

Background: Breast cancer is the leading cause of death for women around the world. Screening mammography is the reference examination, due to its sensitivity for detecting small lesions and micro-calcifications. Therefore, it is essential to ensure quality mammographic examinations with the most optimal dose. These conditions depend on the choice of exposure parameters. Clinically, practices must be evaluated in order to determine the most appropriate exposure parameters. Material and Methods: We performed our measurements on a mobile mammography unit (PLANMED Sofie-classic.) in Morocco. A solid dosimeter (AGMS Radcal) and a MTM 100 phantom allow to quantify the delivered dose and the image quality. For image quality assessment, scores are defined by the rate of visible inserts (MTM 100 phantom), obtained and compared for each acquisition. Results: The results show that the parameters of the mammography unit on which we have made our measurements can be improved in order to offer a better compromise between image quality and breast dose. The last one can be reduced up from 13.27% to 22.16%, while preserving comparable image quality.

Keywords: Mammography, Breast Dose, Image Quality, Phantom

Procedia PDF Downloads 160
5518 Modeling the Impacts of Road Construction on Lands Values

Authors: Maha Almumaiz, Harry Evdorides

Abstract:

Change in land value typically occurs when a new interurban road construction causes an increase in accessibility; this change in the adjacent lands values differs according to land characteristics such as geographic location, land use type, land area and sale time (appraisal time). A multiple regression model is obtained to predict the percent change in land value (CLV) based on four independent variables namely land distance from the constructed road, area of land, nature of land use and time from the works completion of the road. The random values of percent change in land value were generated using Microsoft Excel with a range of up to 35%. The trend of change in land value with the four independent variables was determined from the literature references. The statistical analysis and model building process has been made by using the IBM SPSS V23 software. The Regression model suggests, for lands that are located within 3 miles as the straight distance from the road, the percent CLV is between (0-35%) which is depending on many factors including distance from the constructed road, land use, land area and time from works completion of the new road.

Keywords: interurban road, land use types, new road construction, percent CLV, regression model

Procedia PDF Downloads 258
5517 Microwave Absorption Properties of Low Density Polyethelene-Cobalt Ferrite Nanocomposite

Authors: Reza Fazaeli, Reza Eslami-Farsani, Hamid Targhagh

Abstract:

Low density polyethylene (LDPE) nanocomposites with 3, 5 and 7 wt. % cobalt ferrite (CoFe2O4) nanopowder fabricated with extrusion mixing and followed up by hot press to reach compact samples. The transmission/reflection measurements were carried out with a network analyzer in the frequency range of 8-12 GHz. By increasing the percent of CoFe2O4 nanopowder, reflection loss (S11) increases, while transferring loss (S21) decreases. Reflectivity (R) calculations made using S11 and S21. Increase in percent of CoFe2O4 nanopowder up to 7 wt. % in composite leaded to higher reflectivity amount, and revealed that increasing the percent of CoFe2O4 nanopowder up to 7 wt. % leads to further microwave absorption in 8-12 GHz range.

Keywords: nanocomposite, cobalt ferrite, low density polyethylene, microwave absorption

Procedia PDF Downloads 270
5516 Influence of Pediococcus Pentasaceus Isolate “Dadih” (Buffalo Milk Fermended in Bamboo) the Bowel Frequence, Secretory Immunoglobulin a Level and Height of Ileum Villi of the Mice EPEC Induced Diarrhea

Authors: Endang Purwati Rahayuningsih

Abstract:

The aim of this study is Enteropathogenic Eschericia coli O157 (EPEC) is one of the pathogen that can cause inflamation and damage intestinal mucosa, which is leading diarrhea. Inflamation in the intestinal mucosa proved by the presence of secretory Immunoglobulin A (sIgA) on the feces. Isolate dadih is Pediococcus pentosaceus (P. pentosaceus) as a probiotic lactic acid bacteria (LAB) is very usefull to improve sIgA and intestinal mucosa. The objective, to determine the dose and duration administration of P. pentosaceus for bowel frequence, sIgA level and height of illeum villi in mice EPEC-induced diarrhea. Method, using Complete Randomized design studies in mice EPEC-induced diarrhea. Mice was classified into 2 factors. A factor (dose of probiotic) and B factor (duration of probiotic observation) consisted of 0 hour, 12 hours, 24 hours and 36 hours. A factor consisted of negative control, positive control (mice induced by EPEC) and 3 different dose experimental mice. The results were a very significant interaction between dose and duration administration of P. pentosaceus. Mean of the most frequent defecation of mice EPEC-induced was 55 graetly reduced into 12 ,after 24 hours administration P. pentosaceus dose 2 x 1010 cfu/g, Mean of sIgA level of mice induced EPEC was 1,60 μg/ml, very significant different (p<0,01). Mean of sIgA level after 24 administration P. pentosaceus dose 2 x 1010cfu/g was 2,65 μg/ml. Mean of height of illeum villi after induced EPEC 53,04 μm with very significant different after 24 hours administration P. pentosaceus dose 2 x 1010cfu/g (142,881μm). This study concluded that P. pentosaceus dose 2 x 1010cfu/g after 24 hours is very beneficial to reduced bowel frequence, increase sIgA level and improve the height illeum villi of mice EPEC-induced diarrhea.

Keywords: Pediococcus pentosaceus, sIgA, enteropathogenic Eschericia coli O157, diarrhea, illeum villi

Procedia PDF Downloads 462
5515 Dosimetric Comparison of Conventional Optimization Methods with Inverse Planning Simulated Annealing Technique

Authors: Shraddha Srivastava, N. K. Painuly, S. P. Mishra, Navin Singh, Muhsin Punchankandy, Kirti Srivastava, M. L. B. Bhatt

Abstract:

Various optimization methods used in interstitial brachytherapy are based on dwell positions and dwell weights alteration to produce dose distribution based on the implant geometry. Since these optimization schemes are not anatomy based, they could lead to deviations from the desired plan. This study was henceforth carried out to compare anatomy-based Inverse Planning Simulated Annealing (IPSA) optimization technique with graphical and geometrical optimization methods in interstitial high dose rate brachytherapy planning of cervical carcinoma. Six patients with 12 CT data sets of MUPIT implants in HDR brachytherapy of cervical cancer were prospectively studied. HR-CTV and organs at risk (OARs) were contoured in Oncentra treatment planning system (TPS) using GYN GEC-ESTRO guidelines on cervical carcinoma. Three sets of plans were generated for each fraction using IPSA, graphical optimization (GrOPT) and geometrical optimization (GOPT) methods. All patients were treated to a dose of 20 Gy in 2 fractions. The main objective was to cover at least 95% of HR-CTV with 100% of the prescribed dose (V100 ≥ 95% of HR-CTV). IPSA, GrOPT, and GOPT based plans were compared in terms of target coverage, OAR doses, homogeneity index (HI) and conformity index (COIN) using dose-volume histogram (DVH). Target volume coverage (mean V100) was found to be 93.980.87%, 91.341.02% and 85.052.84% for IPSA, GrOPT and GOPT plans respectively. Mean D90 (minimum dose received by 90% of HR-CTV) values for IPSA, GrOPT and GOPT plans were 10.19 ± 1.07 Gy, 10.17 ± 0.12 Gy and 7.99 ± 1.0 Gy respectively, while D100 (minimum dose received by 100% volume of HR-CTV) for IPSA, GrOPT and GOPT plans was 6.55 ± 0.85 Gy, 6.55 ± 0.65 Gy, 4.73 ± 0.14 Gy respectively. IPSA plans resulted in lower doses to the bladder (D₂

Keywords: cervical cancer, HDR brachytherapy, IPSA, MUPIT

Procedia PDF Downloads 173
5514 Libido and Semen Quality Characteristics of Post-Pubertal Rabbit Bucks Fed Ginger Rhizome Meal Based Diets

Authors: I. P. Ogbuewu, I. F. Etuk, V. U. Odoemelam, I. C. Okoli, M. U. Iloeje

Abstract:

The effect of dietary ginger rhizome meal on libido and semen characteristics of post-pubertal rabbit bucks was investigated in an experiment that lasted for 12 weeks. Thirty-six post-pubertal bucks were randomly assigned to 4 dietary groups of 9 rabbits each in a completely randomized design. Four experimental diets were formulated to contain ginger rhizome meal at 0 g/kg feed (BT0), 5g/kg feed (BT5), 10 g/kg feed (BT10), and 15g/kg feed (BT15) were fed ad libitum to the experimental animals. Results revealed that semen colour changed from cream milky to milky. Data on semen pH and sperm concentration were similar (p>0.05) among the dietary groups. Semen volume for the bucks in BT0 (0.64 mL) and BT5 (0.60 mL) groups were significantly (p<0.05) higher than those in BT10 (0.44 mL) and BT15 (0.46 mL) groups. Total spermatozoa concentration value was significantly (p<0.05) higher in BT0 and BT5 groups than those in BT10 and BT15 groups. Sperm motility and percent live sperm declined (p<0.05) progressively among the treatment groups. Percent dead sperm were significantly (p<0.05) lower for bucks in BT0 group than in BT10 and BT15 groups. Reaction time had a dose-dependent increase; however, the observed difference was not significant (p>0.05). These results indicate that the inclusion of ginger rhizome meal at 5-15g per kg feed in ration for post-pubertal rabbit bucks could cause mild depressive effect on semen production and quality.

Keywords: rabbits, semen, libido, ginger

Procedia PDF Downloads 548
5513 Gamma Irradiation Effects on the Magnetic Properties of Hard Ferrites

Authors: F. Abbas Pour Khotbehsara, B. Salehpour, A. Kianvash

Abstract:

Many industrial materials like magnets need to be tested for the radiation environment expected at linear colliders (LC) where the accelerator and detectors will be subjected to large influences of beta, neutron and gamma’s over their life Gamma irradiation of the permanent sample magnets using a 60Co source was investigated up to an absorbed dose of 700Mrad shows a negligible effect on some magnetic properties of Nd-Fe-B. In this work, it has been tried to investigate the change of some important properties of Barium hexa ferrite. Results showed little decreases of magnetic properties at doses rang of 0.5 to 2.5 Mrad. But at the gamma irradiation dose up to 10 Mrad it is showed a few increase of properties. Also study of gamma irradiation of Nd-Fe-B showed considerably increase of magnetic properties.

Keywords: gamma ray irradiation, hard ferrite, magnetic coefficient, magnetic material, radiation dose

Procedia PDF Downloads 229
5512 Assessment of Dose: Area Product of Common Radiographic Examinations in Selected Southern Nigerian Hospitals

Authors: Lateef Bamidele

Abstract:

Over the years, radiographic examinations are the most used diagnostic tools in the Nigerian health care system, but most diagnostic examinations carried out do not have records of patient doses. Lack of adequate information on patient doses has been a major hindrance in quantifying the radiological risk associated with radiographic examinations. This study aimed at estimating dose–area product (DAP) of patient examined in X-Ray units in selected hospitals in Southern Nigeria. The standard projections selected are chest posterior-anterior (PA), abdomen anterior-posterior (AP), pelvis AP, pelvis lateral (LAT), skull AP/PA, skull LAT, lumbar spine AP, lumbar spine, LAT. Measurement of entrance surface dose (ESD) was carried out using thermoluminescent dosimeter (TLD). Measured ESDs were converted into DAP using the beam area of patients. The results show that the mean DAP ranged from 0.17 to 18.35 Gycm². The results obtained in this study when compared with those of NRPB-HPE were found to be higher. These are an indication of non optimization of operational conditions.

Keywords: dose–area product, radiographic examinations, patient doses, optimization

Procedia PDF Downloads 166
5511 An Infrared Inorganic Scintillating Detector Applied in Radiation Therapy

Authors: Sree Bash Chandra Debnath, Didier Tonneau, Carole Fauquet, Agnes Tallet, Julien Darreon

Abstract:

Purpose: Inorganic scintillating dosimetry is the most recent promising technique to solve several dosimetric issues and provide quality assurance in radiation therapy. Despite several advantages, the major issue of using scintillating detectors is the Cerenkov effect, typically induced in the visible emission range. In this context, the purpose of this research work is to evaluate the performance of a novel infrared inorganic scintillator detector (IR-ISD) in the radiation therapy treatment to ensure Cerenkov free signal and the best matches between the delivered and prescribed doses during treatment. Methods: A simple and small-scale infrared inorganic scintillating detector of 100 µm diameter with a sensitive scintillating volume of 2x10-6 mm3 was developed. A prototype of the dose verification system has been introduced based on PTIR1470/F (provided by Phosphor Technology®) material used in the proposed novel IR-ISD. The detector was tested on an Elekta LINAC system tuned at 6 MV/15MV and a brachytherapy source (Ir-192) used in the patient treatment protocol. The associated dose rate was measured in count rate (photons/s) using a highly sensitive photon counter (sensitivity ~20ph/s). Overall measurements were performed in IBATM water tank phantoms by following international Technical Reports series recommendations (TRS 381) for radiotherapy and TG43U1 recommendations for brachytherapy. The performance of the detector was tested through several dosimetric parameters such as PDD, beam profiling, Cerenkov measurement, dose linearity, dose rate linearity repeatability, and scintillator stability. Finally, a comparative study is also shown using a reference microdiamond dosimeter, Monte-Carlo (MC) simulation, and data from recent literature. Results: This study is highlighting the complete removal of the Cerenkov effect especially for small field radiation beam characterization. The detector provides an entire linear response with the dose in the 4cGy to 800 cGy range, independently of the field size selected from 5 x 5 cm² down to 0.5 x 0.5 cm². A perfect repeatability (0.2 % variation from average) with day-to-day reproducibility (0.3% variation) was observed. Measurements demonstrated that ISD has superlinear behavior with dose rate (R2=1) varying from 50 cGy/s to 1000 cGy/s. PDD profiles obtained in water present identical behavior with a build-up maximum depth dose at 15 mm for different small fields irradiation. A low dimension of 0.5 x 0.5 cm² field profiles have been characterized, and the field cross profile presents a Gaussian-like shape. The standard deviation (1σ) of the scintillating signal remains within 0.02% while having a very low convolution effect, thanks to lower sensitive volume. Finally, during brachytherapy, a comparison with MC simulations shows that considering energy dependency, measurement agrees within 0.8% till 0.2 cm source to detector distance. Conclusion: The proposed scintillating detector in this study shows no- Cerenkov radiation and efficient performance for several radiation therapy measurement parameters. Therefore, it is anticipated that the IR-ISD system can be promoted to validate with direct clinical investigations, such as appropriate dose verification and quality control in the Treatment Planning System (TPS).

Keywords: IR-Scintillating detector, dose measurement, micro-scintillators, Cerenkov effect

Procedia PDF Downloads 171
5510 The Effect of Parents BMI on Overweight and Obesity Elementary School Students in Behbahan City

Authors: Hosseini Siahi Zohreh, Sana Mohammad Jafar

Abstract:

The prevalence of overweight and obesity in children and adolescents has increased in recent decades in different countries. Childhood obesity, increases the risk of adult obesity and its related diseases. Determine the prevalence of the problem in different populations results to screening and adequate intervention and the effects of early and late complications. Various studies have shown Parents and family environment has a significant impact on the incidence of overweight and obesity in children. As parental obesity is directly related to child obesity. In this study were selected randomly 60 girl students with a BMI above the 95th percentile (as fat) and BMI greater than 85 and less than 95 (overweight). So 60 were selected randomly of girl students with a BMI of between 5 and 85 (normal). In the case of boys was done exactly the same. Case and control groups were matched according to age and grade for statistical analysis of SPPS software version 17. According to results the prevalence of overweight and obesity in girl students respectively is 8.7 percent and 13.76 percent and in boy students 9.9 percent and 10.42 percent. Also was not found in boys group the relationship significant between obesity and overweight with parents BMI. Whereas in girls group was found a significant relationship.

Keywords: parents BMI, overweight, obesity, primary school students

Procedia PDF Downloads 505
5509 Comparison of the Dose Reached to the Rectum and Bladder in Two Treatment Methods by Tandem and Ovoid and Tandem and Ring in the High Dose Rate Brachytherapy of Cervical Cancer

Authors: Akbar Haghzadeh Saraskanroud, Amir Hossein Yahyavi Zanjani, Niloofar Kargar, Hanieh Ahrabi

Abstract:

Cervical cancer refers to an unusual growth of cells in the cervix. The cervix is the lower part of the uterus, which connects to the vagina. Various risk factors such as human papillomavirus (HPV), having a weakened immune system, smoking or breathing in secondhand smoke, reproductive factors, and obesity play important roles in causing most cervical cancers. When cervical cancer happens, surgery is often the first treatment option to remove it. Other treatments might include chemotherapy and targeted therapy medicines. Radiation therapy with high-energy photon beams also may be used. Sometimes combined treatment, including radiation with low-dose chemotherapy, was applied. Intracavitary brachytherapy is an integral part of radiotherapy for locally advanced gynecologic malignancies such as cervical cancer. In the treatment of cervical cancer, there are different tools for doing brachytherapy. Two combinations of different applicators for this purpose are Tandem and Ovoid and Tandem and Ring. This study evaluated the dose differences between these two methods in the organs at risk of the rectum, sigmoid, and bladder. In this study, the treatment planswere simulated by the Oncentra treatment planning system and Tandem, Ovid, and Rings of different sizes. CT scan images of 23 patients were treated with HDR_BT Elekta Flexitron system were used for this study. Contouring of HR-CTV, rectum and bladder was performed for all patients. Then, the received dose of 0.1 and 0.2cc volumes of organs at risk were obtained and compared for these two methods: T-Ovoid and T-Ring. By doing investigations and dose measurements of points A and B and the volumes specified by ICRU, it seems that when comparing ring and ovoid to tandem and ovoid, the total dose to the rectum was lower by about 11%, and the bladder was 7%. In the case of HR CTV, this comparison showed that this ratio is about 7% better. Figure 1 shows the amount of decrease in rectum dose in the T-Ring method compared to T-Ovoid. Figure 2 indicates the amount of decrease in bladder dose in the T-Ring method compared to T-Ovoid. Finally, figure 3 illustrates the amount of HR-CTV coverage in the T-Ring method compared to the T-Ovoid.

Keywords: cervical cancer, brachytherapy, rectum, tandem and ovoid, tandem and ring.

Procedia PDF Downloads 22