Search results for: ultrasensitive detection in blood
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5533

Search results for: ultrasensitive detection in blood

5473 Detection of Intravenous Infiltration Using Impedance Parameters in Patients in a Long-Term Care Hospital

Authors: Ihn Sook Jeong, Eun Joo Lee, Jae Hyung Kim, Gun Ho Kim, Young Jun Hwang

Abstract:

This study investigated intravenous (IV) infiltration using bioelectrical impedance for 27 hospitalized patients in a long-term care hospital. Impedance parameters showed significant differences before and after infiltration as follows. First, the resistance (R) after infiltration significantly decreased compared to the initial resistance. This indicates that the IV solution flowing from the vein due to infiltration accumulates in the extracellular fluid (ECF). Second, the relative resistance at 50 kHz was 0.94 ± 0.07 in 9 subjects without infiltration and was 0.75 ± 0.12 in 18 subjects with infiltration. Third, the magnitude of the reactance (Xc) decreased after infiltration. This is because IV solution and blood components released from the vein tend to aggregate in the cell membrane (and acts analogously to the linear/parallel circuit), thereby increasing the capacitance (Cm) of the cell membrane and reducing the magnitude of reactance. Finally, the data points plotted in the R-Xc graph were distributed on the upper right before infiltration but on the lower left after infiltration. This indicates that the infiltration caused accumulation of fluid or blood components in the epidermal and subcutaneous tissues, resulting in reduced resistance and reactance, thereby lowering integrity of the cell membrane. Our findings suggest that bioelectrical impedance is an effective method for detection of infiltration in a noninvasive and quantitative manner.

Keywords: intravenous infiltration, impedance, parameters, resistance, reactance

Procedia PDF Downloads 151
5472 Detecting the Blood of Femoral and Carotid Artery of Swine Using Photoacoustic Tomography in-vivo

Authors: M. Y. Lee, S. H. Park, S. M. Yu, H. S. Jo, C. G. Song

Abstract:

Photoacoustic imaging is the imaging technology that combines the optical imaging with ultrasound. It also provides the high contrast and resolution due to optical and ultrasound imaging, respectively. For these reasons, many studies take experiment in order to apply this method for many diagnoses. We developed the real-time photoacoustic tomography (PAT) system using linear-ultrasound transducer. In this study, we conduct the experiment using swine and detect the blood of carotid artery and femoral artery. We measured the blood of femoral and carotid artery of swine and reconstructed the image using 950nm due to the HbO₂ absorption coefficient. The photoacoustic image is overlaid with ultrasound image in order to match the position. In blood of artery, major composition of blood is HbO₂. In this result, we can measure the blood of artery.

Keywords: photoacoustic tomography, swine artery, carotid artery, femoral artery

Procedia PDF Downloads 221
5471 Microfluidic Paper-Based Electrochemical Biosensor

Authors: Ahmad Manbohi, Seyyed Hamid Ahmadi

Abstract:

A low-cost paper-based microfluidic device (PAD) for the multiplex electrochemical determination of glucose, uric acid, and dopamine in biological fluids was developed. Using wax printing, PAD containing a central zone, six channels, and six detection zones was fabricated, and the electrodes were printed on detection zones using pre-made electrodes template. For each analyte, two detection zones were used. The carbon working electrode was coated with chitosan-BSA (and enzymes for glucose and uric acid). To detect glucose and uric acid, enzymatic reactions were employed. These reactions involve enzyme-catalyzed redox reactions of the analytes and produce free electrons for electrochemical measurement. Calibration curves were linear (R² > 0.980) in the range of 0-80 mM for glucose, 0.09–0.9 mM for dopamine, and 0–50 mM for uric acid, respectively. Blood samples were successfully analyzed by the proposed method.

Keywords: biological fluids, biomarkers, microfluidic paper-based electrochemical biosensors, Multiplex

Procedia PDF Downloads 257
5470 Securing Web Servers by the Intrusion Detection System (IDS)

Authors: Yousef Farhaoui

Abstract:

An IDS is a tool which is used to improve the level of security. We present in this paper different architectures of IDS. We will also discuss measures that define the effectiveness of IDS and the very recent works of standardization and homogenization of IDS. At the end, we propose a new model of IDS called BiIDS (IDS Based on the two principles of detection) for securing web servers and applications by the Intrusion Detection System (IDS).

Keywords: intrusion detection, architectures, characteristic, tools, security, web server

Procedia PDF Downloads 384
5469 A Preliminary Outcome of the Effect of an Accumulating 10,000 Daily Steps on Blood Pressure and Diabetes in Overweight Thai Participants

Authors: Kornanong Yuenyongchaiwat, Duangnate Pepatsitipong, Panthip Sangprasert

Abstract:

High blood pressure and diabetes have been suggested as being non-communicable disease (NCDs), and there is one of the components of the definition of metabolic syndrome. Therefore, the purpose of this study was to evaluate the effect of a 12-week pedometer based community walking intervention on change in resting blood pressure and blood glucose in participants with overweight in the community setting. Method: Participants were recruited both males and females who had a sedentary lifestyle aged 35-59 years (mean aged 49.67 years). A longitudinal quasi-experimental study was designed with 35 overweight participants who had body mass index ≥ 25 kg/m2. These volunteers were assigned to the 12-week pedometer-based walking program (an accumulated at least 10,000 steps a day). Blood pressure and blood glucose were measured initially before and after 12-week intervention. Results: Systolic blood pressure and heart rate were significantly lower in 30 individuals who had accumulated 10,000 steps d-1 in the intervention group at 12 week follow-up (-13.74 mmHg and 5.3 bpm, respectively). In addition, reduction in blood glucose (-14.89 mmol) in the intervention participants was statistically significant (p < .001). A regression analysis indicated that reductions in systolic blood pressure were significantly related to the increase in steps per day. Conclusion: The accumulation of least 10,000 steps d-1 resulted in decreased resting systolic blood pressure and blood glucose in overweight participants. This has also shown that an increase in physical activity in overweight participants with sedentary lifestyle by accumulating at least 10,000 steps a day can reduce the risk of cardiovascular disease (e.g., hypertension and diabetes).

Keywords: blood glucose, blood pressure, diabetes, hypertension, physical activity, walking

Procedia PDF Downloads 251
5468 Dopamine and Serotonin Levels in Blood Samples of Jordanian Children Who Stutter

Authors: Mazin Alqhazo, Ayat Bani Rashaid

Abstract:

This study examines the levels of dopamine and serotonin in blood samples of children who stutter compared with normal fluent speakers. Blood specimens from 50 children who stutter (6 females, 44 males) and 50 normal children matched age and gender were collected for the purpose of the current study. The concentrations of dopamine and serotonin were measured using the 1100 series high-performance liquid chromatography coupled with ultraviolet detector instrument (HPLC-UV). It was revealed that dopamine level in the blood samples of stuttering group and fluent group was not significant (P = 0.769), whereas the level of serotonin was significantly higher in the blood samples of stuttering group than the blood samples of fluent normal group (P = 0.015). It is concluded that serotonin blockers could be used in future studies to evaluate its role as a medication for the treatment of stuttering.

Keywords: dopamine, serotonin, stuttering, fluent speakers

Procedia PDF Downloads 126
5467 Suggestion for Malware Detection Agent Considering Network Environment

Authors: Ji-Hoon Hong, Dong-Hee Kim, Nam-Uk Kim, Tai-Myoung Chung

Abstract:

Smartphone users are increasing rapidly. Accordingly, many companies are running BYOD (Bring Your Own Device: Policies to bring private-smartphones to the company) policy to increase work efficiency. However, smartphones are always under the threat of malware, thus the company network that is connected smartphone is exposed to serious risks. Most smartphone malware detection techniques are to perform an independent detection (perform the detection of a single target application). In this paper, we analyzed a variety of intrusion detection techniques. Based on the results of analysis propose an agent using the network IDS.

Keywords: android malware detection, software-defined network, interaction environment, android malware detection, software-defined network, interaction environment

Procedia PDF Downloads 402
5466 Improved Skin Detection Using Colour Space and Texture

Authors: Medjram Sofiane, Babahenini Mohamed Chaouki, Mohamed Benali Yamina

Abstract:

Skin detection is an important task for computer vision systems. A good method for skin detection means a good and successful result of the system. The colour is a good descriptor that allows us to detect skin colour in the images, but because of lightings effects and objects that have a similar colour skin, skin detection becomes difficult. In this paper, we proposed a method using the YCbCr colour space for skin detection and lighting effects elimination, then we use the information of texture to eliminate the false regions detected by the YCbCr colour skin model.

Keywords: skin detection, YCbCr, GLCM, texture, human skin

Procedia PDF Downloads 418
5465 Blood Glucose Level Measurement from Breath Analysis

Authors: Tayyab Hassan, Talha Rehman, Qasim Abdul Aziz, Ahmad Salman

Abstract:

The constant monitoring of blood glucose level is necessary for maintaining health of patients and to alert medical specialists to take preemptive measures before the onset of any complication as a result of diabetes. The current clinical monitoring of blood glucose uses invasive methods repeatedly which are uncomfortable and may result in infections in diabetic patients. Several attempts have been made to develop non-invasive techniques for blood glucose measurement. In this regard, the existing methods are not reliable and are less accurate. Other approaches claiming high accuracy have not been tested on extended dataset, and thus, results are not statistically significant. It is a well-known fact that acetone concentration in breath has a direct relation with blood glucose level. In this paper, we have developed the first of its kind, reliable and high accuracy breath analyzer for non-invasive blood glucose measurement. The acetone concentration in breath was measured using MQ 138 sensor in the samples collected from local hospitals in Pakistan involving one hundred patients. The blood glucose levels of these patients are determined using conventional invasive clinical method. We propose a linear regression classifier that is trained to map breath acetone level to the collected blood glucose level achieving high accuracy.

Keywords: blood glucose level, breath acetone concentration, diabetes, linear regression

Procedia PDF Downloads 146
5464 Signal Amplification Using Graphene Oxide in Label Free Biosensor for Pathogen Detection

Authors: Agampodi Promoda Perera, Yong Shin, Mi Kyoung Park

Abstract:

The successful detection of pathogenic bacteria in blood provides important information for early detection, diagnosis and the prevention and treatment of infectious diseases. Silicon microring resonators are refractive-index-based optical biosensors that provide highly sensitive, label-free, real-time multiplexed detection of biomolecules. We demonstrate the technique of using GO (graphene oxide) to enhance the signal output of the silicon microring optical sensor. The activated carboxylic groups in GO molecules bind directly to single stranded DNA with an amino modified 5’ end. This conjugation amplifies the shift in resonant wavelength in a real-time manner. We designed a capture probe for strain Staphylococcus aureus of 21 bp and a longer complementary target sequence of 70 bp. The mismatched target sequence we used was of Streptococcus agalactiae of 70 bp. GO is added after the complementary binding of the probe and target. GO conjugates to the unbound single stranded segment of the target and increase the wavelength shift on the silicon microring resonator. Furthermore, our results show that GO could successfully differentiate between the mismatched DNA sequences from the complementary DNA sequence. Therefore, the proposed concept could effectively enhance sensitivity of pathogen detection sensors.

Keywords: label free biosensor, pathogenic bacteria, graphene oxide, diagnosis

Procedia PDF Downloads 438
5463 Check Red Blood Cells Concentrations of a Blood Sample by Using Photoconductive Antenna

Authors: Ahmed Banda, Alaa Maghrabi, Aiman Fakieh

Abstract:

Terahertz (THz) range lies in the area between 0.1 to 10 THz. The process of generating and detecting THz can be done through different techniques. One of the most familiar techniques is done through a photoconductive antenna (PCA). The process of generating THz radiation at PCA includes applying a laser pump in femtosecond and DC voltage difference. However, photocurrent is generated at PCA, which its value is affected by different parameters (e.g., dielectric properties, DC voltage difference and incident power of laser pump). THz radiation is used for biomedical applications. However, different biomedical fields need new technologies to meet patients’ needs (e.g. blood-related conditions). In this work, a novel method to check the red blood cells (RBCs) concentration of a blood sample using PCA is presented. RBCs constitute 44% of total blood volume. RBCs contain Hemoglobin that transfers oxygen from lungs to body organs. Then it returns to the lungs carrying carbon dioxide, which the body then gets rid of in the process of exhalation. The configuration has been simulated and optimized using COMSOL Multiphysics. The differentiation of RBCs concentration affects its dielectric properties (e.g., the relative permittivity of RBCs in the blood sample). However, the effects of four blood samples (with different concentrations of RBCs) on photocurrent value have been tested. Photocurrent peak value and RBCs concentration are inversely proportional to each other due to the change of dielectric properties of RBCs. It was noticed that photocurrent peak value has dropped from 162.99 nA to 108.66 nA when RBCs concentration has risen from 0% to 100% of a blood sample. The optimization of this method helps to launch new products for diagnosing blood-related conditions (e.g., anemia and leukemia). The resultant electric field from DC components can not be used to count the RBCs of the blood sample.

Keywords: biomedical applications, photoconductive antenna, photocurrent, red blood cells, THz radiation

Procedia PDF Downloads 174
5462 Real-Time Detection of Space Manipulator Self-Collision

Authors: Zhang Xiaodong, Tang Zixin, Liu Xin

Abstract:

In order to avoid self-collision of space manipulators during operation process, a real-time detection method is proposed in this paper. The manipulator is fitted into a cylinder enveloping surface, and then the detection algorithm of collision between cylinders is analyzed. The collision model of space manipulator self-links can be detected by using this algorithm in real-time detection during the operation process. To ensure security of the operation, a safety threshold is designed. The simulation and experiment results verify the effectiveness of the proposed algorithm for a 7-DOF space manipulator.

Keywords: space manipulator, collision detection, self-collision, the real-time collision detection

Procedia PDF Downloads 428
5461 Methane Production from Biomedical Waste (Blood)

Authors: Fatima M. Kabbashi, Abdalla M. Abdalla, Hussam K. Hamad, Elias S. Hassan

Abstract:

This study investigates the production of renewable energy (biogas) from biomedical hazard waste (blood) and eco-friendly disposal. Biogas is produced by the bacterial anaerobic digestion of biomaterial (blood). During digestion process bacterial feeding result in breaking down chemical bonds of the biomaterial and changing its features, by the end of the digestion (biogas production) the remains become manure as known. That has led to the economic and eco-friendly disposal of hazard biomedical waste (blood). The samples (Whole blood, Red blood cells 'RBCs', Blood platelet and Fresh Frozen Plasma ‘FFP’) are collected and measured in terms of carbon to nitrogen C/N ratio and total solid, then filled in connected flasks (three flasks) using water displacement method. The results of trails showed that the platelet and FFP failed to produce flammable gas, but via a gas analyzer, it showed the presence of the following gases: CO, HC, CO₂, and NOX. Otherwise, the blood and RBCs produced flammable gases: Methane-nitrous CH₃NO (99.45%), which has a blue color flame and carbon dioxide CO₂ (0.55%), which has red/yellow color flame. Methane-nitrous is sometimes used as fuel for rockets, some aircraft and racing cars.

Keywords: renewable energy, biogas, biomedical waste, blood, anaerobic digestion, eco-friendly disposal

Procedia PDF Downloads 275
5460 Iris Detection on RGB Image for Controlling Side Mirror

Authors: Norzalina Othman, Nurul Na’imy Wan, Azliza Mohd Rusli, Wan Noor Syahirah Meor Idris

Abstract:

Iris detection is a process where the position of the eyes is extracted from the face images. It is a current method used for many applications such as for security purpose and drowsiness detection. This paper proposes the use of eyes detection in controlling side mirror of motor vehicles. The eyes detection method aims to make driver easy to adjust the side mirrors automatically. The system will determine the midpoint coordinate of eyes detection on RGB (color) image and the input signal from y-coordinate will send it to controller in order to rotate the angle of side mirror on vehicle. The eye position was cropped and the coordinate of midpoint was successfully detected from the circle of iris detection using Viola Jones detection and circular Hough transform methods on RGB image. The coordinate of midpoint from the experiment are tested using controller to determine the angle of rotation on the side mirrors.

Keywords: iris detection, midpoint coordinates, RGB images, side mirror

Procedia PDF Downloads 390
5459 A Study of the Prevalence of Hypertension and Pre Hypertension in Adolescence Age between 10-17 in Ahvaz (2008-2009)

Authors: Armaghan Moravej Aleali, Seyed Mahmoud Latifi, Homeira Rashidi

Abstract:

Objective: High blood pressure in a risk factor for some disease like stroke, coronary heart disease, and renal failure. High blood pressure in children is an increasing health problem. The aim of this present was to determine prevalence of hypertension and pre-hypertension age between 10 to 17 years old. Material & Methods: This descriptive-analytic study was conducted using multiphase sampling method in Ahvaz (Southwest of Iran). A questionnaire include: height, weight, and body mass index, systolic and diastolic blood pressures filled for each participant. Blood pressure was measured twice for each person. For the diagnosis of hypertension, the fourth report of the Diagnosis, Evaluation, and Treatment of High Blood Pressure in Children and Adolescents of the National Health Institute of United States was used. Results: The subject participants of the study were 1707children and adolescents including 922 boys (54%) and 785 girls 46%). The prevalence of high blood pressure was 1.7% (boys 2.5% girls 0.8%). The prevalence of pre-hypertension was 9 % (7.6% in boys, 10.6% in girls). The mean systolic and diastolic blood pressures increased with increasing body mass index. Conclusion: In this study, the prevalence of high blood pressure was found to be lower than other studies in our country. The prevalence of the high blood pressure in boys was significantly higher than girls. This study, like other studies, showed a high correlation between being overweight and an increase in systolic and diastolic blood pressure.

Keywords: hypertension, pre-hypertension, childhood, adolescence

Procedia PDF Downloads 432
5458 To Individualisation of Subject, Donar, by Determination of Serological Markers from Obtain Biological Fluid at Crime Scene

Authors: Arun Kumar, Ravindra Pal Verma, Harsh Sharma, Shani Kumar

Abstract:

For the present study samples was collected from 20 donors with unknown blood group and secretor status had been determined from saliva by using biological fluid. ABO typing on the concentrated samples was successfully performed after 1 month of storage. Urine stained clothing samples are often submitted to forensic science laboratories for ABH blood group antigen determination. The serogenetic markers of semen stains submitted can be used to determine the origin of any of these samples. ABH blood group substances have previously been identified from urine. ABH blood group substance is low in urine in comparison with other body fluids.

Keywords: ABH blood group, crime scene, serological markers, body fluids and urine

Procedia PDF Downloads 548
5457 Molecular Detection of mRNA bcr-abl and Circulating Leukemic Stem Cells CD34+ in Patients with Acute Lymphoblastic Leukemia and Chronic Myeloid Leukemia and Its Association with Clinical Parameters

Authors: B. Gonzalez-Yebra, H. Barajas, P. Palomares, M. Hernandez, O. Torres, M. Ayala, A. L. González, G. Vazquez-Ortiz, M. L. Guzman

Abstract:

Leukemia arises by molecular alterations of the normal hematopoietic stem cell (HSC) transforming it into a leukemic stem cell (LSC) with high cell proliferation, self-renewal, and cell differentiation. Chronic myeloid leukemia (CML) originates from an LSC-leading to elevated proliferation of myeloid cells and acute lymphoblastic leukemia (ALL) originates from an LSC development leading to elevated proliferation of lymphoid cells. In both cases, LSC can be identified by multicolor flow cytometry using several antibodies. However, to date, LSC levels in peripheral blood (PB) are not established well enough in ALL and CML patients. On the other hand, the detection of the minimal residue disease (MRD) in leukemia is mainly based on the identification of the mRNA bcr-abl gene in CML patients and some other genes in ALL patients. There is no a properly biomarker to detect MDR in both types of leukemia. The objective of this study was to determine mRNA bcr-abl and the percentage of LSC in peripheral blood of patients with CML and ALL and identify a possible association between the amount of LSC in PB and clinical data. We included in this study 19 patients with Leukemia. A PB sample was collected per patient and leukocytes were obtained by Ficoll gradient. The immunophenotype for LSC CD34+ was done by flow cytometry analysis with CD33, CD2, CD14, CD16, CD64, HLA-DR, CD13, CD15, CD19, CD10, CD20, CD34, CD38, CD71, CD90, CD117, CD123 monoclonal antibodies. In addition, to identify the presence of the mRNA bcr-abl by RT-PCR, the RNA was isolated using TRIZOL reagent. Molecular (presence of mRNA bcr-abl and LSC CD34+) and clinical results were analyzed with descriptive statistics and a multiple regression analysis was performed to determine statistically significant association. In total, 19 patients (8 patients with ALL and 11 patients with CML) were analyzed, 9 patients with de novo leukemia (ALL = 6 and CML = 3) and 10 under treatment (ALL = 5 and CML = 5). The overall frequency of mRNA bcr-abl was 31% (6/19), and it was negative in ALL patients and positive in 80% in CML patients. On the other hand, LSC was determined in 16/19 leukemia patients (%LSC= 0.02-17.3). The Novo patients had higher percentage of LSC (0.26 to 17.3%) than patients under treatment (0 to 5.93%). The amount of LSC was significantly associated with the amount of LSC were: absence of treatment, the absence of splenomegaly, and a lower number of leukocytes, negative association for the clinical variables age, sex, blasts, and mRNA bcr-abl. In conclusion, patients with de novo leukemia had a higher percentage of circulating LSC than patients under treatment, and it was associated with clinical parameters as lack of treatment, absence of splenomegaly and a lower number of leukocytes. The mRNA bcr-abl detection was only possible in the series of patients with CML, and molecular detection of LSC could be identified in the peripheral blood of all leukemia patients, we believe the identification of circulating LSC may be used as biomarker for the detection of the MRD in leukemia patients.

Keywords: stem cells, leukemia, biomarkers, flow cytometry

Procedia PDF Downloads 331
5456 Automatic Vehicle Detection Using Circular Synthetic Aperture Radar Image

Authors: Leping Chen, Daoxiang An, Xiaotao Huang

Abstract:

Automatic vehicle detection using synthetic aperture radar (SAR) image has been widely researched, as well as using optical remote sensing images. However, most researches treat the detection as an independent problem, failing to make full use of SAR data information. In circular SAR (CSAR), the two long borders of vehicle will shrink if the imaging surface is set higher than the reference one. Based on above variance, an automatic vehicle detection using CSAR image is proposed to enhance detection ability under complex environment, such as vehicles’ closely packing, which confuses the detector. The detection method uses the multiple images generated by different height plane to obtain an energy-concentrated image for detecting and then uses the maximally stable extremal regions method (MSER) to detect vehicles. A result of vehicles’ detection is given to verify the effectiveness and correctness of proposed method.

Keywords: circular SAR, vehicle detection, automatic, imaging

Procedia PDF Downloads 333
5455 Biophysical Features of Glioma-Derived Extracellular Vesicles as Potential Diagnostic Markers

Authors: Abhimanyu Thakur, Youngjin Lee

Abstract:

Glioma is a lethal brain cancer whose early diagnosis and prognosis are limited due to the dearth of a suitable technique for its early detection. Current approaches, including magnetic resonance imaging (MRI), computed tomography (CT), and invasive biopsy for the diagnosis of this lethal disease, hold several limitations, demanding an alternative method. Recently, extracellular vesicles (EVs) have been used in numerous biomarker studies, majorly exosomes and microvesicles (MVs), which are found in most of the cells and biofluids, including blood, cerebrospinal fluid (CSF), and urine. Remarkably, glioma cells (GMs) release a high number of EVs, which are found to cross the blood-brain-barrier (BBB) and impersonate the constituents of parent GMs including protein, and lncRNA; however, biophysical properties of EVs have not been explored yet as a biomarker for glioma. We isolated EVs from cell culture conditioned medium of GMs and regular primary culture, blood, and urine of wild-type (WT)- and glioma mouse models, and characterized by nano tracking analyzer, transmission electron microscopy, immunogold-EM, and differential light scanning. Next, we measured the biophysical parameters of GMs-EVs by using atomic force microscopy. Further, the functional constituents of EVs were examined by FTIR and Raman spectroscopy. Exosomes and MVs-derived from GMs, blood, and urine showed distinction biophysical parameters (roughness, adhesion force, and stiffness) and different from that of regular primary glial cells, WT-blood, and -urine, which can be attributed to the characteristic functional constituents. Therefore, biophysical features can be potential diagnostic biomarkers for glioma.

Keywords: glioma, extracellular vesicles, exosomes, microvesicles, biophysical properties

Procedia PDF Downloads 115
5454 Adaptive CFAR Analysis for Non-Gaussian Distribution

Authors: Bouchemha Amel, Chachoui Takieddine, H. Maalem

Abstract:

Automatic detection of targets in a modern communication system RADAR is based primarily on the concept of adaptive CFAR detector. To have an effective detection, we must minimize the influence of disturbances due to the clutter. The detection algorithm adapts the CFAR detection threshold which is proportional to the average power of the clutter, maintaining a constant probability of false alarm. In this article, we analyze the performance of two variants of adaptive algorithms CA-CFAR and OS-CFAR and we compare the thresholds of these detectors in the marine environment (no-Gaussian) with a Weibull distribution.

Keywords: CFAR, threshold, clutter, distribution, Weibull, detection

Procedia PDF Downloads 548
5453 Intrusion Detection Techniques in Mobile Adhoc Networks: A Review

Authors: Rashid Mahmood, Muhammad Junaid Sarwar

Abstract:

Mobile ad hoc networks (MANETs) use has been well-known from the last few years in the many applications, like mission critical applications. In the (MANETS) prevention method is not adequate as the security concerned, so the detection method should be added to the security issues in (MANETs). The authentication and encryption is considered the first solution of the MANETs problem where as now these are not sufficient as MANET use is increasing. In this paper we are going to present the concept of intrusion detection and then survey some of major intrusion detection techniques in MANET and aim to comparing in some important fields.

Keywords: MANET, IDS, intrusions, signature, detection, prevention

Procedia PDF Downloads 343
5452 Some Reasons for the Pervasiveness of the Blood Feud among Albanians: An Albanian Phenomenon or Lack of Malfunction of the Judicial Structure

Authors: Arburim Iseni, Afrim Aliti, Nagri Rexhepi

Abstract:

The blood feud or blood-taking is a social obligation to commit murder in order to salvage honor questioned by an earlier murder or moral humiliation. This social obligation is still preserved as a stub among Albanians when honor is violated. By the term honor are understood many things, such as honor to the family, house, guest, property, etc. Many Albanian family members are forced to stay locked up at home because of the blood killing, whereas other families abandon their houses and migrate to other places. Nonetheless, Albanians maintain close ties with their extended families, clans, and tribes and thus chances are high that the violence can beget more violence and without reconciliation of the blood these families will always be endangered. One of the reasons for the pervasiveness of the blood feud is the poor social conditions, political imbroglio and the power vacuum which comes from the corrupted and judiciary system of the state. Contrary to this, Albanian blood feud is not a phenomenon present only to the Albanians, but it also takes place in some other cultures and nations, such as: Chechens, Montenegrins, Serbians, and lately more radical one is between Amman and Israel who are at constant feud.

Keywords: honor, blood feud, reconciliation, power vacuum, poor social conditions, political imbroglio

Procedia PDF Downloads 420
5451 Lamb Wave-Based Blood Coagulation Measurement System Using Citrated Plasma

Authors: Hyunjoo Choi, Jeonghun Nam, Chae Seung Lim

Abstract:

Acoustomicrofluidics has gained much attention due to the advantages, such as noninvasiveness and easy integration with other miniaturized systems, for clinical and biological applications. However, a limitation of acoustomicrofluidics is the complicated and costly fabrication process of electrodes. In this study, we propose a low-cost and lithography-free device using Lamb wave for blood analysis. Using a Lamb wave, calcium ion-removed blood plasma and coagulation reagents can be rapidly mixed for blood coagulation test. Due to the coagulation process, the viscosity of the sample increases and the viscosity change can be monitored by internal acoustic streaming of microparticles suspended in the sample droplet. When the acoustic streaming of particles stops by the viscosity increase is defined as the coagulation time. With the addition of calcium ion at 0-25 mM, the coagulation time was measured and compared with the conventional index for blood coagulation analysis, prothrombin time, which showed highly correlated with the correlation coefficient as 0.94. Therefore, our simple and cost-effective Lamb wave-based blood analysis device has the powerful potential to be utilized in clinical settings.

Keywords: acoustomicrofluidics, blood analysis, coagulation, lamb wave

Procedia PDF Downloads 311
5450 A Comparative Study of Virus Detection Techniques

Authors: Sulaiman Al amro, Ali Alkhalifah

Abstract:

The growing number of computer viruses and the detection of zero day malware have been the concern for security researchers for a large period of time. Existing antivirus products (AVs) rely on detecting virus signatures which do not provide a full solution to the problems associated with these viruses. The use of logic formulae to model the behaviour of viruses is one of the most encouraging recent developments in virus research, which provides alternatives to classic virus detection methods. In this paper, we proposed a comparative study about different virus detection techniques. This paper provides the advantages and drawbacks of different detection techniques. Different techniques will be used in this paper to provide a discussion about what technique is more effective to detect computer viruses.

Keywords: computer viruses, virus detection, signature-based, behaviour-based, heuristic-based

Procedia PDF Downloads 441
5449 The Effect of Pixelation on Face Detection: Evidence from Eye Movements

Authors: Kaewmart Pongakkasira

Abstract:

This study investigated how different levels of pixelation affect face detection in natural scenes. Eye movements and reaction times, while observers searched for faces in natural scenes rendered in different ranges of pixels, were recorded. Detection performance for coarse visual detail at lower pixel size (3 x 3) was better than with very blurred detail carried by higher pixel size (9 x 9). The result is consistent with the notion that face detection relies on gross detail information of face-shape template, containing crude shape structure and features. In contrast, detection was impaired when face shape and features are obscured. However, it was considered that the degradation of scenic information might also contribute to the effect. In the next experiment, a more direct measurement of the effect of pixelation on face detection, only the embedded face photographs, but not the scene background, will be filtered.

Keywords: eye movements, face detection, face-shape information, pixelation

Procedia PDF Downloads 287
5448 Performance of Nakagami Fading Channel over Energy Detection Based Spectrum Sensing

Authors: M. Ranjeeth, S. Anuradha

Abstract:

Spectrum sensing is the main feature of cognitive radio technology. Spectrum sensing gives an idea of detecting the presence of the primary users in a licensed spectrum. In this paper we compare the theoretical results of detection probability of different fading environments like Rayleigh, Rician, Nakagami-m fading channels with the simulation results using energy detection based spectrum sensing. The numerical results are plotted as P_f Vs P_d for different SNR values, fading parameters. It is observed that Nakagami fading channel performance is better than other fading channels by using energy detection in spectrum sensing. A MATLAB simulation test bench has been implemented to know the performance of energy detection in different fading channel environment.

Keywords: spectrum sensing, energy detection, fading channels, probability of detection, probability of false alarm

Procedia PDF Downloads 497
5447 Effects of the Non-Newtonian Viscosity of Blood on Flow Field in a Constricted Artery with a Porous Plaque

Authors: Maedeh Shojaeizadeh, Amirreza Yeganegi

Abstract:

Nowadays many people lose their lives due to cardiovascular diseases. Inappropriate food habits and lack of exercise expedite deposit process of fatty substances on inner surface of blood arteries. This abnormal lump disturbs uniform blood flow and reduces oxygen delivery to active organs. This work presents a numerical simulation of Non-Newtonian blood flow in a stenosis vessel. The vessel is considered as two dimensional channel and plaque area is modelled as a homogenous porous medium. To simulate blood flow reaction around stenosis region, we use C++ code and solve coupled Cauchy, Darcy, governing continuity and energy equations. The analyses results show that viscosity power (n) plays an important role in flow separation and the size of the eddy at the downstream edge of the plaque. It is also observed that with increasing (n) value, temperature discontinuity and likelihood of vessel rupture declined.

Keywords: blood flow, computational fluid dynamic, porosity, power law fluid

Procedia PDF Downloads 435
5446 Analysis of Selected Hematological Variables during Three Different Menstrual Phases between Sedentary and Sports Women

Authors: G. Vasanthi

Abstract:

The purpose of the study was to analyse the red blood cells and white blood cells during three different menstrual phases between sedentary and sports women. To achieve this purpose, fifteen female sedentary post graduate students (M.A., M.Sc.) and fifteen students of Master of Physical Education and Sports (M.P.Ed.) women who regularly involved in vigouous sports training and participated in sports competition on different games were selected by adopting random sampling method. All the students were hostelers and their age group was between 20 to 22 years. The blood sample were collected during the mid-period of the three different phases to calculate the red blood cells and white blood cells. The data collected were treated statistically by using analysis of variance. The results reveal that the RBC and WBC is found to be significant between sedentary and sports women during the three different menstrual phases.

Keywords: RBC, WBC, menstrual, proliferative, secretary, sedentary women, sports women

Procedia PDF Downloads 481
5445 The Exact Specification for Consumption of Blood-Pressure Regulating Drugs with a Numerical Model of Pulsatile Micropolar Fluid Flow in Elastic Vessel

Authors: Soroush Maddah, Houra Asgarian, Mahdi Navidbakhsh

Abstract:

In the present paper, the problem of pulsatile micropolar blood flow through an elastic artery has been studied. An arbitrary Lagrangian-Eulerian (ALE) formulation for the governing equations has been produced to model the fully-coupled fluid-structure interaction (FSI) and has been solved numerically using finite difference scheme by exploiting a mesh generation technique which leads to a uniformly spaced grid in the computational plane. Effect of the variations of cardiac output and wall artery module of elasticity on blood pressure with blood-pressure regulating drugs like Atenolol has been determined. Also, a numerical model has been produced to define precisely the effects of various dosages of a drug on blood flow in arteries without the numerous experiments that have many mistakes and expenses.

Keywords: arbitrary Lagrangian-Eulerian, Atenolol, fluid structure interaction, micropolar fluid, pulsatile blood flow

Procedia PDF Downloads 396
5444 Circadian Rhythm of Blood-Sucking Behavior of Female Forcipomyia taiwana

Authors: Chang-Liang Shih, Kuei-Min Liao, Ya-Yuan Wang, Wu-Chun Tu

Abstract:

Forcipomyia taiwana, an important vexing pest, influences the development of the industry of Taiwan tourism and the quality of country life. Using human-attractant method to investigate the blood-sucking behavior of Forcipomyia taiwana in three districts in Taichung, it revealed that female F. taiwana only exhibits blood-sucking behavior in daytime, not in nighttime. The blooding-sucking behavior of female F. taiwana was affected by some factors, i.e., season and atmospheric factors. During 2008 to 2010, our study revealed that blood-sucking behavior commenced from 7:00 to 8:00 in the spring equinox, the summer solstice and the autumnal equinox, but from 8:00 to 9:00 in the winter solstice. However, regardless of any seasons, it revealed that blood-sucking behavior reached the acme between 13:00 and 15:00, and then descending. In those four seasons, the summer solstice had longer lighting and higher temperature, the average sucking activity was around 12 hours, on the contrary, the winter solstice had shorter lighting and lower temperature, the average sucking activity bridled to around 8 hours whilst it retrenched to 11 hours in the spring equinox and the autumnal equinox. To analyze the correlation between blood-sucking behavior and atmospheric factors, it revealed that female blood-sucking behavior was correlated positively to temperature and lighting but negatively to humidity. In addition, our study also showed that there is no blood-sucking behavior under 18ºC.

Keywords: Forcipomyia taiwana, circadian rhythm, blood-sucking behavior, season

Procedia PDF Downloads 400