Search results for: ex-vivo heart perfusion
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1170

Search results for: ex-vivo heart perfusion

930 Sudden Death of a Cocaine Body Packer: An Autopsy Examination Findings

Authors: Parthasarathi Pramanik

Abstract:

Body packing is a way of transfer drugs across the international border or any drug prohibited area. The drugs are usually hidden in body packets inside the anatomical body cavities like mouth, intestines, rectum, ear, vagina etc. Cocaine is a very common drug for body packing across the world. A 48 year old male was reported dead in his hotel after complaining of chest pain and vomiting. At autopsy, there were eighty-two white cylindrical body packs in the stomach, small and large intestines. Seals of few of the packets were opened. Toxicological examination revealed presence of cocaine in the stomach, liver, kidney and hair samples. Microscopically, presence of myocardial necrosis with interstitial oedema along with hypertrophy and fibrosis of the myocardial fibre suggested heart failure due to cocaine cardio toxicity. However, focal lymphocyte infiltration and perivascular fibrosis in the myocardium also indicated chronic cocaine toxicity of the deceased. After careful autopsy examination it was considered the victim was died due congestive heart failure secondary to acute and chronic cocaine poisoning.

Keywords: cardiac failure, cocaine, body packer, sudden death

Procedia PDF Downloads 291
929 Tissue-Specific Distribution of Cytochrome P450 1A1 and 3A in Rainbow Trout (Oncorhynchus mykiss)

Authors: Viktoriia Burkina, Vladimir Zlabek, Galia Zamaratskaia

Abstract:

Cytochromes P450 (CYP) are important family of enzymes in Phase I metabolism. Environmental pollutants often act as inducers of the gene expression and activities CYP1A1 and CYP3A-like isoforms in fish. The activities are generally measured in the fish liver or gills, and less is known about tissue distribution of expression. In present study, the CYP1A1 and CYP3A-like activities were measured in rainbow trout liver, gill, intestine, heart, brain and gonads. The activities of CYP1A1 and CYP3A-like proteins were estimated as the rates of 7-ethoxyresorufin-O-deethylation (EROD) and benzyloxy-4-trifluoromethylcoumarin-O-debenzyloxylation (BFCOD), respectively. The CYP1A1 and CYP3A-like activities were detectable in all investigated fish tissues, with the highest activity in hepatic tissue followed by heart > brain > gill > intestine > gonads. To confirm the presence of CYP1A1 in different tissues, EROD activity was measured in presence of the selective inhibitors ellipticine (CYP1A1), ketoconazole (CYP3A), 8-methoxypsoralen (human CYP2A) and diallyl sulphide (CYP2E1). It was found that ellipticine, ketoconazole and 8-methoxypsoralen inhibited hepatic EROD activity by 88-98%. Ellipticine inhibited gill, intestine, and gonad EROD activity by 50%. In conclusion, EROD and BFCOD activities were detected in rainbow trout liver, gill, intestine, heart, brain and gonads. Further studies are needed to fully identify all CYP450 isoforms responsible for these activities. Acknowledgement: The study was financially supported by the Ministry of Education, Youth and Sports of the Czech Republic - projects „CENAKVA “(No. CZ.1.05/2.1.00/01.0024), “CENAKVA Center Development “(No. CZ.1.05/2.1.00/19.0380), “CENAKVA II “(No. LO1205 under the NPU I program), and "Development of USB - International mobility (No. CZ.02.2.69/0.0/0.0/16_027/0008364).

Keywords: BFCOD, EROD, fish, phase I metabolism, selective inhibitors

Procedia PDF Downloads 128
928 Comparison of Effects over the Autonomic Nervous System When Using Force Training and Interval Training in Indoor Cycling with University Students

Authors: Daniel Botero, Oscar Rubiano, Pedro P. Barragan, Jaime Baron, Leonardo Rodriguez Perdomo, Jaime Rodriguez

Abstract:

In the last decade interval training (IT) has gained importance when is compare with strength training (ST). However, there are few studies analyzing the impact of these training over the autonomic nervous system (ANS). This work has aimed to compare the activity of the autonomic nervous system, when is expose to an IT or ST indoor cycling mode. After approval by the ethics committee, a cross-over clinical trial with 22 healthy participants (age 21 ± 3 years) was implemented. The selection of participants for the groups with sequence force-interval (F-I) and interval-force (I-F) was made randomly with assignation of 11 participants for each group. The temporal series of heart rate was obtained before and after each training using the POLAR TEAM® heart monitor. The evaluation of the ANS was performed with spectral analysis of the heart rate variability (HRV) using the fast Fourier transform (Kubios software). A training of 8 weeks in each sequence (4 weeks with each training) with an intermediate period of two weeks of washout was implemented for each group. The power parameter of the HRV in the low frequency band (LF = 0.04-0.15Hz related to the sympathetic nervous system), high frequency (HF = 0.15-0.4Hz, related to the parasympathetic) and LF/HF (with reference to a modulation of parasympathetic over the sympathetic), were calculated. Afterward, the difference between the parameters before and after was realized. Then, to evaluate statistical differences between each training was implemented the method of Wellek (Wellek and Blettner, 2012, Medicine, 109 (15), 276-81). To determine the difference of effect over parasympathetic when FT and IT are used, the T test is implemented obtaining a T value of 0.73 with p-value ≤ 0.1. For the sympathetic was obtained a T of 0.33 with p ≤ 0.1 and for LF/HF the T was 1.44 with a p ≥ 0.1. Then, the carry over effect was evaluated and was not present. Significant changes over autonomic activity with strength or interval training were not observed. However, a modulation of the parasympathetic over the sympathetic can be observed. Probably, these findings should be explained because the sample is little and/or the time of training was insufficient to generate changes.

Keywords: autonomic nervous, force training, indoor cycling, interval training

Procedia PDF Downloads 192
927 Quality Assurance in Cardiac Disorder Detection Images

Authors: Anam Naveed, Asma Andleeb, Mehreen Sirshar

Abstract:

In the article, Image processing techniques have been applied on cardiac images for enhancing the image quality. Two types of methodologies considers for survey, invasive techniques and non-invasive techniques. Different image processes for improvement of cardiac image quality and reduce the amount of radiation exposure for invasive techniques are explored. Different image processing algorithms for enhancing the noninvasive cardiac image qualities are described. Beside these two methodologies, third methodology has applied on live streaming of heart rate on ECG window for extracting necessary information, removing noise and enhancing quality. Sensitivity analyses have been carried out to investigate the impacts of cardiac images for diagnosis of cardiac arteries disease and how the enhancement on images will help the cardiologist to diagnoses disease. The paper evaluates strengths and weaknesses of different techniques applied for improved the image quality and draw a conclusion. Some specific limitations must be considered for whole survey, like the patient heart beat must be 70-75 beats/minute while doing the angiography, similarly patient weight and exposure radiation amount has some limitation.

Keywords: cardiac images, CT angiography, critical analysis, exposure radiation, invasive techniques, invasive techniques, non-invasive techniques

Procedia PDF Downloads 317
926 Characterization of Coronary Artery Obstruction and Related Findings in Ischemic Heart Patients Using Cardiac Scintigraphy

Authors: Yousif Mohamed Y. Abdallah, Eltayeb Wagi Allah Eltayeb, Mohamed E. Gar-elnabi, Mohamed Ahmed Ali

Abstract:

To characterize coronary artery obstruction and related findings in ischemic heart patients using cardiac scintigraphy for the identification of myocardial ischemia, 146 patients were studied at basal conditions and also asked for fasting after night till the intravenous injection of the radiopharmaceutical. After the injection time about 15 to 20 minutes, the patient should eat a fatty meal and chocolate for the good excretion of the gall bladder, to evaluate the performance and regional wall motion of the left ventricle (LV). The results showed that the body mass index percentage in this sample was in range of 43.05 to 61.05. The number of patients who were catheter candidates were 56 with 43% and the patients that were not candidate to cathode were 74 patients with 57% of all patients. For the group of patients where type of ischemia was assessed, 29.5% of patients had reversible posterior and inferior wall, 15.1% of patients had fixed large from apex to base, 9.6% of patients had mild basal inferior wall, 4.8 % of patients had mild anterior wall, 6.2% of patients had antro-septal and 34.9% of patients had moderate ischemia.

Keywords: myocardial ischemia, myocardial scintigraphy, contrast ventriculography, coronary artery obstruction

Procedia PDF Downloads 539
925 Simplified Measurement of Occupational Energy Expenditure

Authors: J. Wicks

Abstract:

Aim: To develop a simple methodology to allow collected heart rate (HR) data from inexpensive wearable devices to be expressed in a suitable format (METs) to quantitate occupational (and recreational) activity. Introduction: Assessment of occupational activity is commonly done by utilizing questionnaires in combination with prescribed MET levels of a vast range of previously measured activities. However for any individual the intensity of performing a specific activity can vary significantly. Ideally objective measurement of individual activity is preferred. Though there are a wide range of HR recording devices there is a distinct lack methodology to allow processing of collected data to quantitate energy expenditure (EE). The HR index equation expresses METs in relation to relative HR i.e. the ratio of activity HR to resting HR. The use of this equation provides a simple utility for objective measurement of EE. Methods: During a typical occupational work period of approximately 8 hours HR data was recorded using a Polar RS 400 wrist monitor. Recorded data was downloaded to a Windows PC and non HR data was stripped from the ASCII file using ‘Notepad’. The HR data was exported to a spread sheet program and sorted by HR range into a histogram format. Three HRs were determined, namely a resting HR (the HR delimiting the lowest 30 minutes of recorded data), a mean HR and a peak HR (the HR delimiting the highest 30 minutes of recorded data). HR indices were calculated (mean index equals mean HR/rest HR and peak index equals peak HR/rest HR) with mean and peak indices being converted to METs using the HR index equation. Conclusion: Inexpensive HR recording devices can be utilized to make reasonable estimates of occupational (or recreational) EE suitable for large scale demographic screening by utilizing the HR index equation. The intrinsic value of the HR index equation is that it is independent of factors that influence absolute HR, namely fitness, smoking and beta-blockade.

Keywords: energy expenditure, heart rate histograms, heart rate index, occupational activity

Procedia PDF Downloads 269
924 A Study of NT-ProBNP and ETCO2 in Patients Presenting with Acute Dyspnoea

Authors: Dipti Chand, Riya Saboo

Abstract:

OBJECTIVES: Early and correct diagnosis may present a significant clinical challenge in diagnosis of patients presenting to Emergency Department with Acute Dyspnoea. The common cause of acute dyspnoea and respiratory distress in Emergency Department are Decompensated Heart Failure (HF), Chronic Obstructive Pulmonary Disease (COPD), Asthma, Pneumonia, Acute Respiratory Distress Syndrome (ARDS), Pulmonary Embolism (PE), and other causes like anaemia. The aim of the study was to measure NT-pro Brain Natriuretic Peptide (BNP) and exhaled End-Tidal Carbon dioxide (ETCO2) in patients presenting with dyspnoea. MATERIAL AND METHODS: This prospective, cross-sectional and observational study was performed at the Government Medical College and Hospital, Nagpur, between October 2019 and October 2021 in patients admitted to the Medicine Intensive Care Unit. Three groups of patients were compared: (1) HFrelated acute dyspnoea group (n = 52), (2) pulmonary (COPD/PE)-related acute dyspnoea group (n = 31) and (3) sepsis with ARDS-related dyspnoea group (n = 13). All patients underwent initial clinical examination with a recording of initial vital parameters along with on-admission ETCO2 measurement, NT-proBNP testing, arterial blood gas analysis, lung ultrasound examination, 2D echocardiography, chest X-rays, and other relevant diagnostic laboratory testing. RESULTS: 96 patients were included in the study. Median NT-proBNP was found to be high for the Heart Failure group (11,480 pg/ml), followed by the sepsis group (780 pg/ml), and pulmonary group had an Nt ProBNP of 231 pg/ml. The mean ETCO2 value was maximum in the pulmonary group (48.610 mmHg) followed by Heart Failure (31.51 mmHg) and the sepsis group (19.46 mmHg). The results were found to be statistically significant (P < 0.05). CONCLUSION: NT-proBNP has high diagnostic accuracy in differentiating acute HF-related dyspnoea from pulmonary (COPD and ARDS)-related acute dyspnoea. The higher levels of ETCO2 help in diagnosing patients with COPD.

Keywords: NT PRO BNP, ETCO2, dyspnoea, lung USG

Procedia PDF Downloads 51
923 The Convergence of IoT and Machine Learning: A Survey of Real-time Stress Detection System

Authors: Shreyas Gambhirrao, Aditya Vichare, Aniket Tembhurne, Shahuraj Bhosale

Abstract:

In today's rapidly evolving environment, stress has emerged as a significant health concern across different age groups. Stress that isn't controlled, whether it comes from job responsibilities, health issues, or the never-ending news cycle, can have a negative effect on our well-being. The problem is further aggravated by the ongoing connection to technology. In this high-tech age, identifying and controlling stress is vital. In order to solve this health issue, the study focuses on three key metrics for stress detection: body temperature, heart rate, and galvanic skin response (GSR). These parameters along with the Support Vector Machine classifier assist the system to categorize stress into three groups: 1) Stressed, 2) Not stressed, and 3) Moderate stress. Proposed training model, a NodeMCU combined with particular sensors collects data in real-time and rapidly categorizes individuals based on their stress levels. Real-time stress detection is made possible by this creative combination of hardware and software.

Keywords: real time stress detection, NodeMCU, sensors, heart-rate, body temperature, galvanic skin response (GSR), support vector machine

Procedia PDF Downloads 44
922 Portable System for the Acquisition and Processing of Electrocardiographic Signals to Obtain Different Metrics of Heart Rate Variability

Authors: Daniel F. Bohorquez, Luis M. Agudelo, Henry H. León

Abstract:

Heart rate variability (HRV) is defined as the temporary variation between heartbeats or RR intervals (distance between R waves in an electrocardiographic signal). This distance is currently a recognized biomarker. With the analysis of the distance, it is possible to assess the sympathetic and parasympathetic nervous systems. These systems are responsible for the regulation of the cardiac muscle. The analysis allows health specialists and researchers to diagnose various pathologies based on this variation. For the acquisition and analysis of HRV taken from a cardiac electrical signal, electronic equipment and analysis software that work independently are currently used. This complicates and delays the process of interpretation and diagnosis. With this delay, the health condition of patients can be put at greater risk. This can lead to an untimely treatment. This document presents a single portable device capable of acquiring electrocardiographic signals and calculating a total of 19 HRV metrics. This reduces the time required, resulting in a timelier intervention. The device has an electrocardiographic signal acquisition card attached to a microcontroller capable of transmitting the cardiac signal wirelessly to a mobile device. In addition, a mobile application was designed to analyze the cardiac waveform. The device calculates the RR and different metrics. The application allows a user to visualize in real-time the cardiac signal and the 19 metrics. The information is exported to a cloud database for remote analysis. The study was performed under controlled conditions in the simulated hospital of the Universidad de la Sabana, Colombia. A total of 60 signals were acquired and analyzed. The device was compared against two reference systems. The results show a strong level of correlation (r > 0.95, p < 0.05) between the 19 metrics compared. Therefore, the use of the portable system evaluated in clinical scenarios controlled by medical specialists and researchers is recommended for the evaluation of the condition of the cardiac system.

Keywords: biological signal análisis, heart rate variability (HRV), HRV metrics, mobile app, portable device.

Procedia PDF Downloads 150
921 About Multi-Resolution Techniques for Large Eddy Simulation of Reactive Multi-Phase Flows

Authors: Giacomo Rossi, Bernardo Favini, Eugenio Giacomazzi, Franca Rita Picchia, Nunzio Maria Salvatore Arcidiacono

Abstract:

A numerical technique for mesh refinement in the HeaRT (Heat Release and Transfer) numerical code is presented. In the CFD framework, Large Eddy Simulation (LES) approach is gaining in importance as a tool for simulating turbulent combustion processes, also if this approach has an high computational cost due to the complexity of the turbulent modeling and the high number of grid points necessary to obtain a good numerical solution. In particular, when a numerical simulation of a big domain is performed with a structured grid, the number of grid points can increase so much that the simulation becomes impossible: this problem can be overcame with a mesh refinement technique. Mesh refinement technique developed for HeaRT numerical code (a staggered finite difference code) is based on an high order reconstruction of the variables at the grid interfaces by means of a least square quasi-ENO interpolation: numerical code is written in modern Fortran (2003 standard of newer) and is parallelized using domain decomposition and message passing interface (MPI) standard.

Keywords: LES, multi-resolution, ENO, fortran

Procedia PDF Downloads 334
920 Accuracy of Fitbit Charge 4 for Measuring Heart Rate in Parkinson’s Patients During Intense Exercise

Authors: Giulia Colonna, Jocelyn Hoye, Bart de Laat, Gelsina Stanley, Jose Key, Alaaddin Ibrahimy, Sule Tinaz, Evan D. Morris

Abstract:

Parkinson’s disease (PD) is the second most common neurodegenerative disease and affects approximately 1% of the world’s population. Increasing evidence suggests that aerobic physical exercise can be beneficial in mitigating both motor and non-motor symptoms of the disease. In a recent pilot study of the role of exercise on PD, we sought to confirm exercise intensity by monitoring heart rate (HR). For this purpose, we asked participants to wear a chest strap heart rate monitor (Polar Electro Oy, Kempele). The device sometimes proved uncomfortable. Looking forward to larger clinical trials, it would be convenient to employ a more comfortable and user friendly device. The Fitbit Charge 4 (Fitbit Inc) is a potentially comfortable, user-friendly solution since it is a wrist-worn heart rate monitor. Polar H10 has been used in large trials, and for our purposes, we treated it as the gold standard for the beat-to-beat period (R-R interval) assessment. In previous literature, it has been shown that Fitbit Charge 4 has comparable accuracy to Polar H10 in healthy subjects. It has yet to be determined if the Fitbit is as accurate as the Polar H10 in subjects with PD or in clinical populations, generally. Goal: To compare the Fitbit Charge 4 to the Polar H10 for monitoring HR in PD subjects engaging in an intensive exercise program. Methods: A total of 596 exercise sessions from 11 subjects (6 males) were collected simultaneously by both devices. Subjects with early-stage PD (Hoehn & Yahr <=2) were enrolled in a 6 months exercise training program designed for PD patients. Subjects participated in 3 one-hour exercise sessions per week. They wore both Fitbit and Polar H10 during each session. Sessions included rest, warm-up, intensive exercise, and cool-down periods. We calculated the bias in the HR via Fitbit under rest (5min) and intensive exercise (20min) by comparing the mean HR during each of the periods to the respective means measured by the Polar (HRFitbit – HRPolar). We also measured the sensitivity and specificity of Fitbit for detecting HRs that exceed the threshold for intensive exercise, defined as 70% of an individual’s theoretical maximum HR. Different types of correlation between the two devices were investigated. Results: The mean bias was 1.68 bpm at rest and 6.29 bpm during high intensity exercise, with an overestimation by Fitbit in both conditions. The mean bias of Fitbit across both rest and intensive exercise periods was 3.98 bpm. The sensitivity of the device in identifying high intensity exercise sessions was 97.14 %. The correlation between the two devices was non-linear, suggesting a saturation tendency of Fitbit to saturate at high values of HR. Conclusion: The performance of Fitbit Charge 4 is comparable to Polar H10 for assessing exercise intensity in a cohort of PD subjects. The device should be considered a reasonable replacement for the more cumbersome chest strap technology in future similar studies of clinical populations.

Keywords: fitbit, heart rate measurements, parkinson’s disease, wrist-wearable devices

Procedia PDF Downloads 65
919 Formation and Development of Polyspecies Biofilm on the Surface of Ti-7.5Mo Nanotubes Growth

Authors: Escada A. L. A., Pereira C. A., Jorge A. O. C., Alves Claro A. P. R.

Abstract:

In the present work, a susceptibility and efficacy of the Ti–7.5Mo alloy nanotube and Ti–7.5Mo alloy to bacterial biofilm formation after surface treatment was evaluated. The Ti–7.5Mo alloy was obtained in arc furnace under an argon atmosphere. Ingots were then homogenized under vacuum at 1100 ◦C for 86.4 ks to eliminate chemical segregation and after cold worked discs were cutting. Nanotubes were processed using anodic oxidation in 0.25% NH4F electrolyte solution. Biofilms were grown in discs immersed in sterile brain heart infusion broth (BHI) containing 5% sucrose, inoculated with microbial suspension (106 cells/ml) and incubated for 5 days. Next, the discs were placed in tubes with sterile physiological solution 0.9% sodium chloride (NaCl) and sonicated for to disperse the biofilms. Tenfold serial dilutions were carried and aliquots seeded in selective agar, which were then incubated for 48 h. Then, the numbers CFU/ml (log 10) were counted and analyzed statistically. Scanning electron microscopy (SEM) on discs with biofilms groupswas performed, atomic force microscope (AFM) and contact angle. The results show that there is no difference in bacterial adhesion between Ti–7.5Mo alloy nanotube pure titanium and Ti–7.5Mo alloy.

Keywords: biofilm, titanium alloy, brain heart infusion, scanning electron microscopy

Procedia PDF Downloads 293
918 Anomalous Origin of Bilateral Testicular Arteries: A Case Report

Authors: Arthi Ganapathy, Arithra Banerjee, Saroj Kaler

Abstract:

Abdominal aorta is the sole purveyor of all organs in the abdomen. Anomalies of its main trunk or its branches are to be meticulously observed as it effects the perfusion of an organ. Varying patterns of the testicular artery is one of them. The origin and course of testicular arteries have to be identified carefully during various surgical procedures like renal transplant, intra abdominal surgeries and even in orthopedic surgery like spine surgery. With the advent of new intra-abdominal therapeutic and diagnostic techniques, the anatomy of testicular arteries has assumed much more significance. Though the variations of the testicular vein are well documented, the variations of the testicular artery are not so frequent in incidence. We report a case of the bilateral aberrant origin of the testicular artery from polar renal arteries. We also discuss its developmental basis. Such anomalies if left unnoticed will lead to serious intraoperative complications during procedures on retroperitoneal organs. Any damage to testicular arteries will compromise the function of the gonads.

Keywords: cadaver, gonadal, renal, surgery

Procedia PDF Downloads 196
917 Contactless Heart Rate Measurement System based on FMCW Radar and LSTM for Automotive Applications

Authors: Asma Omri, Iheb Sifaoui, Sofiane Sayahi, Hichem Besbes

Abstract:

Future vehicle systems demand advanced capabilities, notably in-cabin life detection and driver monitoring systems, with a particular emphasis on drowsiness detection. To meet these requirements, several techniques employ artificial intelligence methods based on real-time vital sign measurements. In parallel, Frequency-Modulated Continuous-Wave (FMCW) radar technology has garnered considerable attention in the domains of healthcare and biomedical engineering for non-invasive vital sign monitoring. FMCW radar offers a multitude of advantages, including its non-intrusive nature, continuous monitoring capacity, and its ability to penetrate through clothing. In this paper, we propose a system utilizing the AWR6843AOP radar from Texas Instruments (TI) to extract precise vital sign information. The radar allows us to estimate Ballistocardiogram (BCG) signals, which capture the mechanical movements of the body, particularly the ballistic forces generated by heartbeats and respiration. These signals are rich sources of information about the cardiac cycle, rendering them suitable for heart rate estimation. The process begins with real-time subject positioning, followed by clutter removal, computation of Doppler phase differences, and the use of various filtering methods to accurately capture subtle physiological movements. To address the challenges associated with FMCW radar-based vital sign monitoring, including motion artifacts due to subjects' movement or radar micro-vibrations, Long Short-Term Memory (LSTM) networks are implemented. LSTM's adaptability to different heart rate patterns and ability to handle real-time data make it suitable for continuous monitoring applications. Several crucial steps were taken, including feature extraction (involving amplitude, time intervals, and signal morphology), sequence modeling, heart rate estimation through the analysis of detected cardiac cycles and their temporal relationships, and performance evaluation using metrics such as Root Mean Square Error (RMSE) and correlation with reference heart rate measurements. For dataset construction and LSTM training, a comprehensive data collection system was established, integrating the AWR6843AOP radar, a Heart Rate Belt, and a smart watch for ground truth measurements. Rigorous synchronization of these devices ensured data accuracy. Twenty participants engaged in various scenarios, encompassing indoor and real-world conditions within a moving vehicle equipped with the radar system. Static and dynamic subject’s conditions were considered. The heart rate estimation through LSTM outperforms traditional signal processing techniques that rely on filtering, Fast Fourier Transform (FFT), and thresholding. It delivers an average accuracy of approximately 91% with an RMSE of 1.01 beat per minute (bpm). In conclusion, this paper underscores the promising potential of FMCW radar technology integrated with artificial intelligence algorithms in the context of automotive applications. This innovation not only enhances road safety but also paves the way for its integration into the automotive ecosystem to improve driver well-being and overall vehicular safety.

Keywords: ballistocardiogram, FMCW Radar, vital sign monitoring, LSTM

Procedia PDF Downloads 42
916 A Collaborative Approach to Improving Mental and Physical Health-Related Outcomes for a Heart Transplant Patient Through Music and Art Therapy Treatment

Authors: Elizabeth Laguaite, Alexandria Purdy

Abstract:

Heart transplant recipients face psycho-physiological stressors, including pain, lengthy hospitalizations, delirium, and existential crises. They pose an increased risk for Post Traumatic Stress Disorder (PTSD) and can be a predictor of poorer mental and physical Health-Related Quality of Life (HRQOL) outcomes and increased mortality. There is limited research on the prevention of Post Traumatic Stress Symptoms (PTSS) in transplant patients. This case report focuses on a collaborative Music and Art Therapy intervention used to improve outcomes for HMH transplant recipient John (Alias). John, a 58-year-old man with congestive heart failure, was admitted to HMH in February of 2021 with cardiogenic shock, cannulated with an Intra-aortic Balloon Pump, Impella 5.5, and Venoarterial Extracorporeal Membrane Oxygenation (VA-ECMO) as a bridge to heart and kidney transplant. He was listed as status 1 for transplant. Music Therapy and Art Therapy (MT and AT) were ordered by the physician for mood regulation, trauma processing and anxiety management. During MT/AT sessions, John reported a history of anxiety and depression exacerbated by medical acuity, shortness of breath, and lengthy hospitalizations. He expressed difficulty sleeping, pain, and existential questions. Initially seen individually by MT/AT, it was determined he could benefit from a collaborative approach due to similar thematic content within sessions. A Life Review intervention was developed by MT/AT. The purpose was for him to creatively express, reflect and process his medical narrative, including the identification of positive and negative events leading up to admission at HMH, the journey to transplant, and his hope for the future. Through this intervention, he created artworks that symbolized each event and paired them with songs, two of which were composed with the MT during treatment. As of September 2023, John has not been readmitted to the hospital and expressed that this treatment is what “got him through transplant”. MT and AT can provide opportunities for a patient to reminisce through creative expression, leading to a shift in the personal meaning of these experiences, promoting resolution, and ameliorating associated trauma. The closer to trauma it is processed, the less likely to develop PTSD. This collaborative MT/AT approach could improve long-term outcomes by reducing mortality and readmission rates for transplant patients.

Keywords: art therapy, music therapy, critical care, PTSD, trauma, transplant

Procedia PDF Downloads 46
915 Using Virtual Reality Exergaming to Improve Health of College Students

Authors: Juanita Wallace, Mark Jackson, Bethany Jurs

Abstract:

Introduction: Exergames, VR games used as a form of exercise, are being used to reduce sedentary lifestyles in a vast number of populations. However, there is a distinct lack of research comparing the physiological response during VR exergaming to that of traditional exercises. The purpose of this study was to create a foundationary investigation establishing changes in physiological responses resulting from VR exergaming in a college aged population. Methods: In this IRB approved study, college aged students were recruited to play a virtual reality exergame (Beat Saber) on the Oculus Quest 2 (Facebook, 2021) in either a control group (CG) or training group (TG). Both groups consisted of subjects who were not habitual users of virtual reality. The CG played VR one time per week for three weeks and the TG played 150 min/week three weeks. Each group played the same nine Beat Saber songs, in a randomized order, during 30 minute sessions. Song difficulty was increased during play based on song performance. Subjects completed a pre- and posttests at which the following was collected: • Beat Saber Game Metrics: song level played, song score, number of beats completed per song and accuracy (beats completed/total beats) • Physiological Data: heart rate (max and avg.), active calories • Demographics Results: A total of 20 subjects completed the study; nine in the CG (3 males, 6 females) and 11 (5 males, 6 females) in the TG. • Beat Saber Song Metrics: The TG improved performance from a normal/hard difficulty to hard/expert. The CG stayed at the normal/hard difficulty. At the pretest there was no difference in game accuracy between groups. However, at the posttest the CG had a higher accuracy. • Physiological Data (Table 1): Average heart rates were similar between the TG and CG at both the pre- and posttest. However, the TG expended more total calories. Discussion: Due to the lack of peer reviewed literature on c exergaming using Beat Saber, the results of this study cannot be directly compared. However, the results of this study can be compared with the previously established trends for traditional exercise. In traditional exercise, an increase in training volume equates to increased efficiency at the activity. The TG should naturally increase in difficulty at a faster rate than the CG because they played 150 hours per week. Heart rate and caloric responses also increase during traditional exercise as load increases (i.e. speed or resistance). The TG reported an increase in total calories due to a higher difficulty of play. The song accuracy decreases in the TG can be explained by the increased difficulty of play. Conclusion: VR exergaming is comparable to traditional exercise for loads within the 50-70% of maximum heart rate. The ability to use VR for health could motivate individuals who do not engage in traditional exercise. In addition, individuals in health professions can and should promote VR exergaming as a viable way to increase physical activity and improve health in their clients/patients.

Keywords: virtual reality, exergaming, health, heart rate, wellness

Procedia PDF Downloads 154
914 Gender Based Variability Time Series Complexity Analysis

Authors: Ramesh K. Sunkaria, Puneeta Marwaha

Abstract:

Nonlinear methods of heart rate variability (HRV) analysis are becoming more popular. It has been observed that complexity measures quantify the regularity and uncertainty of cardiovascular RR-interval time series. In the present work, SampEn has been evaluated in healthy Normal Sinus Rhythm (NSR) male and female subjects for different data lengths and tolerance level r. It is demonstrated that SampEn is small for higher values of tolerance r. Also SampEn value of healthy female group is higher than that of healthy male group for short data length and with increase in data length both groups overlap each other and it is difficult to distinguish them. The SampEn gives inaccurate results by assigning higher value to female group, because male subject have more complex HRV pattern than that of female subjects. Therefore, this traditional algorithm exhibits higher complexity for healthy female subjects than for healthy male subjects, which is misleading observation. This may be due to the fact that SampEn do not account for multiple time scales inherent in the physiologic time series and the hidden spatial and temporal fluctuations remains unexplored.

Keywords: heart rate variability, normal sinus rhythm group, RR interval time series, sample entropy

Procedia PDF Downloads 248
913 Efficacy of a Zeolite as a Detoxifier in Broiler Feed Contaminated with Aflatoxin B1

Authors: R. Stevens, W.L. Bryden

Abstract:

The objective of this study was to determine the efficacy of zeolite in preventing the adverse effects of aflatoxin B1 (AFB1) in broilers. A total of 540 one-day-old Ross chicks were randomly divided into nine treatments, with four replicate pens per treatment and 15 chicks per pen. The treatments included 3 Levels of AFB1 (0,1and 2 mg/kg diet) and 3 levels of zeolite (0, 1.5 and 3 %) in a 3 ×3 factorial arrangement. The experimental treatments commenced on d 7 post-hatch. A starter diet was provided from d 1 to 14, a grower diet from d 15 to 28 and a finisher diet from d 29 to d 49. Diets were based on corn and soybeans and formulated to meet the bird's requirements. The evaluated parameters were as follows: Bodyweight, daily gain, feed intake (FI), feed conversion (FC), relative weights of organs (carcass, liver, heart and abdominal fat) and clinical biochemistry parameters: alanine aminotransferase (ALT) and aspartate aminotransferase (AST). Bodyweight, daily gain and FC were significantly (P<0.05) impaired by aflatoxin. Relative weights of the liver and heart were also affected. The addition of zeolite (1.5 and 3 %) to the contaminated diets ameliorated the effects of aflatoxin, especially at the higher level of inclusion. These data demonstrate that this specific sorbent (zeolite) can protect against the toxicity of AFB1in young broiler chicks.

Keywords: aflatoxin, broiler, toxicity, zeolite

Procedia PDF Downloads 124
912 Diffusion Dynamics of Leech-Heart Inter-Neuron Model

Authors: Arnab Mondal, Sanjeev Kumar Sharma, Ranjit Kumar Upadhyay

Abstract:

We study the spatiotemporal dynamics of a neuronal cable. The processes of one- dimensional (1D) and 2D diffusion are considered for a single variable, which is the membrane voltage, i.e., membrane voltage diffusively interacts for spatiotemporal pattern formalism. The recovery and other variables interact through the membrane voltage. A 3D Leech-Heart (LH) model is introduced to investigate the nonlinear responses of an excitable neuronal cable. The deterministic LH model shows different types of firing properties. We explore the parameter space of the uncoupled LH model and based on the bifurcation diagram, considering v_k2_ashift as a bifurcation parameter, we analyze the 1D diffusion dynamics in three regimes: bursting, regular spiking, and a quiescent state. Depending on parameters, it is shown that the diffusive system may generate regular and irregular bursting or spiking behavior. Further, it is explored a 2D diffusion acting on the membrane voltage, where different types of patterns can be observed. The results show that the LH neurons with different firing characteristics depending on the control parameters participate in a collective behavior of an information processing system that depends on the overall network.

Keywords: bifurcation, pattern formation, spatio-temporal dynamics, stability analysis

Procedia PDF Downloads 187
911 The Enhancement of Training of Military Pilots Using Psychophysiological Methods

Authors: G. Kloudova, M. Stehlik

Abstract:

Optimal human performance is a key goal in the professional setting of military pilots, which is a highly challenging atmosphere. The aviation environment requires substantial cognitive effort and is rich in potential stressors. Therefore, it is important to analyze variables such as mental workload to ensure safe conditions. Pilot mental workload could be measured using several tools, but most of them are very subjective. This paper details research conducted with military pilots using psychophysiological methods such as electroencephalography (EEG) and heart rate (HR) monitoring. The data were measured in a simulator as well as under real flight conditions. All of the pilots were exposed to highly demanding flight tasks and showed big individual response differences. On that basis, the individual pattern for each pilot was created counting different EEG features and heart rate variations. Later on, it was possible to distinguish the most difficult flight tasks for each pilot that should be more extensively trained. For training purposes, an application was developed for the instructors to decide which of the specific tasks to focus on during follow-up training. This complex system can help instructors detect the mentally demanding parts of the flight and enhance the training of military pilots to achieve optimal performance.

Keywords: cognitive effort, human performance, military pilots, psychophysiological methods

Procedia PDF Downloads 206
910 Signal Estimation and Closed Loop System Performance in Atrial Fibrillation Monitoring with Communication Channels

Authors: Mohammad Obeidat, Ayman Mansour

Abstract:

In this paper a unique issue rising from feedback control of Atrial Fibrillation monitoring system with embedded communication channels has been investigated. One of the important factors to measure the performance of the feedback control closed loop system is disturbance and noise attenuation factor. It is important that the feedback system can attenuate such disturbances on the atrial fibrillation heart rate signals. Communication channels depend on network traffic conditions and deliver different throughput, implying that the sampling intervals may change. Since signal estimation is updated on the arrival of new data, its dynamics actually change with the sampling interval. Consequently, interaction among sampling, signal estimation, and the controller will introduce new issues in remotely controlled Atrial Fibrillation system. This paper treats a remotely controlled atrial fibrillation system with one communication channel which connects between the heart rate and rhythm measurements to the remote controller. Typical and optimal signal estimation schemes is represented by a signal averaging filter with its time constant derived from the step size of the signal estimation algorithm.

Keywords: atrial fibrillation, communication channels, closed loop, estimation

Procedia PDF Downloads 352
909 Internet of Things Based Patient Health Monitoring System

Authors: G. Yoga Sairam Teja, K. Harsha Vardhan, A. Vinay Kumar, K. Nithish Kumar, Ch. Shanthi Priyag

Abstract:

The emergence of the Internet of Things (IoT) has facilitated better device control and monitoring in the modern world. The constant monitoring of a patient would be drastically altered by the usage of IoT in healthcare. As we've seen in the case of the COVID-19 pandemic, it's important to keep oneself untouched while continuously checking on the patient's heart rate and temperature. Additionally, patients with paralysis should be closely watched, especially if they are elderly and in need of special care. Our "IoT BASED PATIENT HEALTH MONITORING SYSTEM" project uses IoT to track patient health conditions in an effort to address these issues. In this project, the main board is an 8051 microcontroller that connects a number of sensors, including a heart rate sensor, a temperature sensor (LM-35), and a saline water measuring circuit. These sensors are connected via an ESP832 (WiFi) module, which enables the sending of recorded data directly to the cloud so that the patient's health status can be regularly monitored. An LCD is used to monitor the data in offline mode, and a buzzer will sound if any variation from the regular readings occurs. The data in the cloud may be viewed as a graph, making it simple for a user to spot any unusual conditions.

Keywords: IoT, ESP8266, 8051 microcontrollers, sensors

Procedia PDF Downloads 59
908 Effect of Tai-Chi and Cyclic Meditation on Hemodynamic Responses of the Prefrontal Cortex: A Functional near Infrared Spectroscopy

Authors: Singh Deepeshwar, N. K. Manjunath, M. Avinash

Abstract:

Meditation is a self-regulated conscious process associated with improved awareness, perception, attention and overall performance. Different traditional origin of meditation technique may have different effects on autonomic activity and brain functions. Based on this quest, the present study evaluated the effect of Tai-Chi Chuan (TCC, a Chines movement based meditation technique) and Cyclic Meditation (CM, an Indian traditional based stimulation and relaxation meditation technique) on the hemodynamic responses of the prefrontal cortex (PFC) and autonomic functions (such as R-R interval of heart rate variability and respiration). These two meditation practices were compared with simple walking. Employing 64 channel near infrared spectroscopy (NIRS), we measured hemoglobin concentration change (i.e., Oxyhemoglobin [ΔHbO], Deoxyhemoglobin [ΔHbR] and Total hemoglobin change [ΔTHC]) in the bilateral PFC before and after TCC, CM and Walking in young college students (n=25; average mean age ± SD; 23.4 ± 3.1 years). We observed the left PFC activity predominantly modulates sympathetic activity effects during the Tai-Chi whereas CM showed changes on right PFC with vagal dominance. However, the changes in oxyhemoglobin and total blood volume change after Tai-Chi was significant higher (p < 0.05, spam t-maps) on the left hemisphere, whereas after CM, there was a significant increase in oxyhemoglobin (p < 0.01) with a decrease in deoxyhemoglobin (p < 0.05) on right PFC. The normal walking showed decrease in Oxyhemoglobin with an increase in deoxyhemoglobin on left PFC. The autonomic functions result showed a significant increase in RR- interval (p < 0.05) along with significant reductions in HR (p < 0.05) in CM, whereas Tai-chi session showed significant increase in HR (p < 0.05) when compared to walking session. Within a group analysis showed a significant reduction in RR-I and significant increase in HR both in Tai-chi and walking sessions. The CM showed there were a significant improvement in the RR - interval of HRV (p < 0.01) with the reduction of heart rate and breath rate (p < 0.05). The result suggested that Tai-Chi and CM both have a positive effect on left and right prefrontal cortex and increase sympathovagal balance (alertful rest) in autonomic nervous system activity.

Keywords: brain, hemodynamic responses, yoga, meditation, Tai-Chi Chuan (TCC), walking, heart rate variability (HRV)

Procedia PDF Downloads 268
907 A Genetic Identification of Candida Species Causing Intravenous Catheter-Associated Candidemia in Heart Failure Patients

Authors: Seyed Reza Aghili, Tahereh Shokohi, Shirin Sadat Hashemi Fesharaki, Mohammad Ali Boroumand, Bahar Salmanian

Abstract:

Introduction: Intravenous catheter-associated fungal infection as nosocomial infection continue to be a deep problem among hospitalized patients, decreasing quality of life and adding healthcare costs. The capacity of catheters in the spread of candidemia in heart failure patients is obvious. The aim of this study was to evaluate the prevalence and genetic identification of Candida species in heart disorder patients. Material and Methods: This study was conducted in Tehran Hospital of Cardiology Center (Tehran, Iran, 2014) during 1.5 years on the patients hospitalized for at least 7 days and who had central or peripheral vein catheter. Culture of catheters, blood and skin of the location of catheter insertion were applied for detecting Candida colonies in 223 patients. Identification of Candida species was made on the basis of a combination of various phenotypic methods and confirmed by sequencing the ITS1-5.8S-ITS2 region amplified from the genomic DNA using PCR and the NCBI BLAST. Results: Of the 223 patients samples tested, we identified totally 15 Candida isolates obtained from 9 (4.04%) catheter cultures, 3 (1.35%) blood cultures and 2 (0.90%) skin cultures of the catheter insertion areas. On the base of ITS region sequencing, out of nine Candida isolates from catheter, 5(55.6%) C. albicans, 2(22.2%) C. glabrata, 1(11.1%) C. membranifiaciens and 1 (11.1%) C. tropicalis were identified. Among three Candida isolates from blood culture, C. tropicalis, C. carpophila and C. membranifiaciens were identified. Non-candida yeast isolated from one blood culture was Cryptococcus albidus. One case of C. glabrata and one case of Candida albicans were isolated from skin culture of the catheter insertion areas in patients with positive catheter culture. In these patients, ITS region of rDNA sequence showed a similarity between Candida isolated from the skin and catheter. However, the blood samples of these patients were negative for fungal growth. We report two cases of catheter-related candidemia caused by C. membranifiaciens and C. tropicalis on the base of genetic similarity of species isolated from blood and catheter which were treated successfully with intravenous fluconazole and catheter removal. In phenotypic identification methods, we could only identify C. albicans and C. tropicalis and other yeast isolates were diagnosed as Candida sp. Discussion: Although more than 200 species of Candida have been identified, only a few cause diseases in humans. There is some evidence that non-albicans infections are increasing. Many risk factors, including prior antibiotic therapy, use of a central venous catheter, surgery, and parenteral nutrition are considered to be associated with candidemia in hospitalized heart failure patients. Identifying the route of infection in candidemia is difficult. Non-albicans candida as the cause of candidemia is increasing dramatically. By using conventional method, many non-albicans isolates remain unidentified. So, using more sensitive and specific molecular genetic sequencing to clarify the aspects of epidemiology of the unknown candida species infections is essential. The positive blood and catheter cultures for candida isolates and high percentage of similarity of their ITS region of rDNA sequence in these two patients confirmed the diagnosis of intravenous catheter-associated candidemia.

Keywords: catheter-associated infections, heart failure patient, molecular genetic sequencing, ITS region of rDNA, Candidemia

Procedia PDF Downloads 301
906 The Effect of Reverse Trendelenburg Position on the Back Pain after Cardiovascular Angiography and Interventions

Authors: Pramote Thangkratok

Abstract:

The aims of this experimental study were to investigate the effect of Reverse Trendelenburg Position on the Back Pain after Cardiovascular Angiography and Interventions. In addition, to compare bleeding and hematoma occurrences at the Access site between experimental and control groups. The randomized controlled trial (RCT) was conducted in 70 patients who underwent Cardiovascular Angiography and Interventions via the femoral artery and received post procedural care at the intermediate cardiac care unit, Bangkok Heart Hospital. From December 2015 to February 2016. The control group (35 patients) was to get standard care after the intervention, whereas the experimental group (35 patients) was Reverse Trendelenburg Position 30-45 degrees. The groups were not significantly different in terms of demographic characteristics, Age, Gender, BMI, blood pressure, heart rate. While not significantly different from each other, the intensity of back pain control group had a significantly higher pain score than experimental group. Vascular complications in terms of bleeding and hematoma were not significantly different between the control and experimental groups. The findings show that Reverse Trendelenburg Position after Cardiovascular Angiography and Interventions would reduce or prevent the back pain without increasing the chance of bleeding and hematoma.

Keywords: reverse trendelenburg position, back pain, cardiovascular angiography, cardiovascular interventions

Procedia PDF Downloads 242
905 Epidemiology of Congenital Heart Defects in Kazakhstan: Data from Unified National Electronic Healthcare System 2014-2020

Authors: Dmitriy Syssoyev, Aslan Seitkamzin, Natalya Lim, Kamilla Mussina, Abduzhappar Gaipov, Dimitri Poddighe, Dinara Galiyeva

Abstract:

Background: Data on the epidemiology of congenital heart defects (CHD) in Kazakhstan is scarce. Therefore, the aim of this study was to describe the incidence, prevalence and all-cause mortality of patients with CHD in Kazakhstan, using national large-scale registry data from the Unified National Electronic Healthcare System (UNEHS) for the period of 2014-2020. Methods: In this retrospective cohort study, the included data pertained to all patients diagnosed with CHD in Kazakhstan and registered in UNEHS between January 2014 and December 2020. CHD was defined based on International Classification of Diseases 10th Revision (ICD-10) codes Q20-Q26. Incidence, prevalence, and all-cause mortality rates were calculated per 100,000 population. Survival analysis was performed using Cox proportional hazards regression modeling and the Kaplan-Meier method. Results: In total, 66,512 patients were identified. Among them, 59,534 (89.5%) were diagnosed with a single CHD, while 6,978 (10.5%) had more than two CHDs. The median age at diagnosis was 0.08 years (interquartile range (IQR) 0.01 – 0.66) for people with multiple CHD types and 0.39 years (IQR 0.04 – 8.38) for those with a single CHD type. The most common CHD types were atrial septal defect (ASD) and ventricular septal defect (VSD), accounting for 25.8% and 21.2% of single CHD cases, respectively. The most common multiple types of CHD were ASD with VSD (23.4%), ASD with patent ductus arteriosus (PDA) (19.5%), and VSD with PDA (17.7%). The incidence rate of CHD decreased from 64.6 to 47.1 cases per 100,000 population among men and from 68.7 to 42.4 among women. The prevalence rose from 66.1 to 334.1 cases per 100,000 population among men and from 70.8 to 328.7 among women. Mortality rates showed a slight increase from 3.5 to 4.7 deaths per 100,000 in men and from 2.9 to 3.7 in women. Median follow-up was 5.21 years (IQR 2.47 – 11.69). Male sex (HR 1.60, 95% CI 1.45 - 1.77), having multiple CHDs (HR 2.45, 95% CI 2.01 - 2.97), and living in a rural area (HR 1.32, 95% CI 1.19 - 1.47) were associated with a higher risk of all-cause mortality. Conclusion: The incidence of CHD in Kazakhstan has shown a moderate decrease between 2014 and 2020, while prevalence and mortality have increased. Male sex, multiple CHD types, and rural residence were significantly associated with a higher risk of all-cause mortality.

Keywords: congenital heart defects (CHD), epidemiology, incidence, Kazakhstan, mortality, prevalence

Procedia PDF Downloads 50
904 Effects of Spectrotemporal Modulation of Music Profiles on Coherence of Cardiovascular Rhythms

Authors: I-Hui Hsieh, Yu-Hsuan Hu

Abstract:

The powerful effect of music is often associated with changes in physiological responses such as heart rate and respiration. Previous studies demonstrate that Mayer waves of blood pressure, the spontaneous rhythm occurring at 0.1 Hz, corresponds to a progressive crescendo of the musical phrase. However, music contain dynamic changes in temporal and spectral features. As such, it remains unclear which aspects of musical structures optimally affect synchronization of cardiovascular rhythms. This study investigates the independent contribution of spectral pattern, temporal pattern, and dissonance level on synchronization of cardiovascular rhythms. The regularity of acoustical patterns occurring at a periodic rhythm of 0.1 Hz is hypothesized to elicit the strongest coherence of cardiovascular rhythms. Music excerpts taken from twelve pieces of Western classical repertoire were modulated to contain varying degrees of pattern regularity of the acoustic envelope structure. Three levels of dissonance were manipulated by varying the harmonic structure of the accompanying chords. Electrocardiogram and photoplethysmography signals were recorded for 5 minutes of baseline and simultaneously while participants listen to music excerpts randomly presented over headphones in a sitting position. Participants were asked to indicate the pleasantness of each music excerpt by adjusting via a slider presented on screen. Analysis of the Fourier spectral power of blood pressure around 0.1 Hz showed a significant difference between music excerpts characterized by spectral and temporal pattern regularity compared to the same content in random pattern. Phase coherence between heart rate and blood pressure increased significantly during listening to spectrally-regular phrases compared to its matched control phrases. The degree of dissonance of the accompanying chord sequence correlated with level of coherence between heart rate and blood pressure. Results suggest that low-level auditory features of music can entrain coherence of autonomic physiological variables. These findings have potential implications for using music as a clinical and therapeutic intervention for regulating cardiovascular functions.

Keywords: cardiovascular rhythms, coherence, dissonance, pattern regularity

Procedia PDF Downloads 124
903 Quality of Life of Patients on Oral Antiplatelet Therapy in Outpatient Cardiac Department Dr. Hasan Sadikin Central General Hospital Bandung

Authors: Andhiani Sharfina Arnellya, Mochammad Indra Permana, Dika Pramita Destiani, Ellin Febrina

Abstract:

Health Research Data, Ministry of Health of Indonesia in 2007, showed coronary heart disease (CHD) or coronary artery disease (CAD) was the third leading cause of death in Indonesia after hypertension and stroke with 7.2% incidence rate. Antiplatelet is one of the important therapy in management of patients with CHD. In addition to therapeutic effect on patients, quality of life is one aspect of another assessment to see the success of antiplatelet therapy. The purpose of this study was to determine the quality of life of patients on oral antiplatelet therapy in outpatient cardiac department Dr. Hasan Sadikin central general hospital, Bandung, Indonesia. This research is a cross sectional by collecting data through quality of life questionnaire of patients which performed prospectively as primary data and secondary data from medical record of patients. The results of this study showed that 54.3% of patients had a good quality of life, 45% had a moderate quality of life, and 0.7% had a poor quality of life. There are no significant differences in quality of life-based on age, gender, diagnosis, and duration of drug use.

Keywords: antiplatelet, quality of life, coronary artery disease, coronary heart disease

Procedia PDF Downloads 293
902 Possibilities of Postmortem CT to Detection of Gas Accumulations in the Vessels of Dead Newborns with Congenital Sepsis

Authors: Uliana N. Tumanova, Viacheslav M. Lyapin, Vladimir G. Bychenko, Alexandr I. Shchegolev, Gennady T. Sukhikh

Abstract:

It is well known that the gas formed as a result of postmortem decomposition of tissues can be detected already 24-48 hours after death. In addition, the conditions of keeping and storage of the corpse (temperature and humidity of the environment) significantly determine the rate of occurrence and development of posthumous changes. The presence of sepsis is accompanied by faster postmortem decomposition and decay of the organs and tissues of the body. The presence of gas in the vessels and cavities can be revealed fully at postmortem CT. Radiologists must certainly report on the detection of intraorganic or intravascular gas, wich was detected at postmortem CT, to forensic experts or pathologists before the autopsy. This gas can not be detected during autopsy, but it can be very important for establishing a diagnosis. To explore the possibility of postmortem CT for the evaluation of gas accumulations in the newborns' vessels, who died from congenital sepsis. Researched of 44 newborns bodies (25 male and 19 female sex, at the age from 6 hours to 27 days) after 6 - 12 hours of death. The bodies were stored in the refrigerator at a temperature of +4°C in the supine position. Grouped 12 bodies of newborns that died from congenital sepsis. The control group consisted of 32 bodies of newborns that died without signs of sepsis. Postmortem CT examination was performed at the GEMINI TF TOF16 device, before the autopsy. The localizations of gas accumulations in the vessels were determined on the CT tomograms. The sepsis diagnosis was on the basis of clinical and laboratory data and autopsy results. Gases in the vessels were detected in 33.3% of cases in the group with sepsis, and in the control group - in 34.4%. A group with sepsis most often the gas localized in the heart and liver vessels - 50% each, of observations number with the detected gas in the vessels. In the heart cavities, aorta and mesenteric vessels - 25% each. In control most often gas was detected in the liver (63.6%) and abdominal cavity (54.5%) vessels. In 45.5% the gas localized in the cavities, and in 36.4% in the vessels of the heart. In the cerebral vessels and in the aorta gas was detected in 27.3% and 9.1%, respectively. Postmortem CT has high diagnostic capabilities to detect free gas in vessels. Postmortem changes in newborns that died from sepsis do not affect intravascular gas production within 6-12 hours. Radiation methods should be used as a supplement to the autopsy, including as a kind of ‘guide’, with the indication to the forensic medical expert of certain changes identified during CT studies, for better definition of pathological processes during the autopsy. Postmortem CT can be recommend as a first stage of autopsy.

Keywords: congenital sepsis, gas, newborn, postmortem CT

Procedia PDF Downloads 122
901 Alternative Epinephrine Injector to Combat Allergy Induced Anaphylaxis

Authors: Jeremy Bost, Matthew Brett, Jacob Flynn, Weihui Li

Abstract:

One response during anaphylaxis is reduced blood pressure due to blood vessels relaxing and dilating. Epinephrine causes the blood vessels to constrict, which raises blood pressure to counteract the symptoms. When going through an allergic reaction, an Epinephrine injector is used to administer a shot of epinephrine intramuscularly. Epinephrine injectors have become an integral part of day-to-day life for people with allergies. Current Epinephrine injectors (EpiPen) are completely mechanical and have no sensors to monitor the vital signs of patients or give suggestions the optimal time for the shot. The EpiPens are also large and inconvenient to carry daily. The current price of an EpiPen is roughly 600$ for a pack of two. This makes carrying an EpiPen very expensive, especially when they need to be switched out when the epinephrine expires. This new design is in the form of a bracelet, which has the ability to inject epinephrine. The bracelet will be equipped with vital signs monitors that can aid the patient to sense the allergic reaction. The vital signs that would be of interest are blood pressure, heart rate and Electrodermal activity (EDA). The heart rate of the patient will be tracked by a photoplethysmograph (PPG) that is incorporated into the sensors. The heart rate is expected to increase during anaphylaxis. Blood pressure will be monitored through a radar sensor, which monitors the phase changes in electromagnetic waves as they reflect off of the blood vessel. EDA is under autonomic control. Allergen-induced anaphylaxis is caused by a release of chemical mediators from mast cells and basophils, thus changes the autonomic activity of the patient. So by measuring EDA, it will give the wearer an alert on how their autonomic nervous system is reacting. After the vital signs are collected, they will be sent to an application on a smartphone to be analyzed, which can then alert an emergency contact if the epinephrine injector on the bracelet is activated. Overall, this design creates a safer system by aiding the user in keeping track of their epinephrine injector, while making it easier to track their vital signs. Also, our design will be more affordable and more convenient to replace. Rather than replacing the entire product, only the needle and drug will be switched out and not the entire design.

Keywords: allergy, anaphylaxis, epinephrine, injector, vital signs monitor

Procedia PDF Downloads 228