Search results for: controlled
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2357

Search results for: controlled

2087 Determination of Critical Period for Weed Control in the Second Crop Forage Maize (454 Cultivar)

Authors: Farhad Farahvash, Parya Mobaseri

Abstract:

Weeds control based on their critical period leads to less production costs and risks of wide chemical application of weeds control methods. The present study considered effect of weeds control time (weeds interference after 20, 40 and 60 days, weeds full control, weeds interference and weeds control after 20, 40 and 60 days) on growth and yield of forage maize 454. The experiment based on full-randomized blocks design with three replications was conducted at research farm of Islamic Azad University of Tabriz located at 15th km of East Tabriz in 2013. According to the results, weeds interference after 40 and 60 days as well as weeds control after 20 days prevented from decrease of maize biomass resulted from weeds presence while weeds interference after 20 days, weeds interference and weeds control after 40 and 60 days led respectively to 41.2%, 35%, 25% and 32.5% decrease of forage maize biomass. The weeds-influenced decrease was manifested at different parts of the plant depending on presence period of weeds. Decrease of fresh weight of ear and fresh weight of leaf and stem was observed due to weeds interference after 20 days and weeds interference. If weeds are controlled after 60 days, decrease of ear weight and fresh weight of stem will lead to biomass decrease. Also, if weeds are controlled after 40 days, decrease of fresh weight of maize stems will result in biomass decrease. Ear traits were affected by weeds control treatment. Being affected by treatments of weeds interference after 20 days, weeds non-interference, weeds control after 40 and 60 days, ear length was shortened 29.9 %, 41.4 %, 27.6 % and 37.2 %, respectively. The stem diameter demonstrated a significant decrease although it was only affected by treatments of weeds interference and weeds control after 60 days. Considering results of the present study, generally, it is suggested to control weeds during initial 20-60 days of maize growth in order to prevent undesirable effect of weeds on growth, production and production biomass of maize and decrease of production costs.

Keywords: maize, competition, weed, biomass

Procedia PDF Downloads 334
2086 Comparison of Efficacy between Low-Residue Diet and Clear-Liquid Diet in Colonoscopic Bowel Preparation at a Surgical Clinic: A Randomized Controlled Trial

Authors: Sopana Wongtawee

Abstract:

Purpose: Adequate bowel cleansing is essential for a high quality, effective and safe colonoscopy. The aims of this study were to compare the efficacy of bowel preparation based on a low-residue diet before 8:00 followed by a clear-liquid diet, and a low-residue diet until 16:00 one day before colonoscopy using sodium phosphate solution (Xubil ®), the side effects of the two protocols and the patient satisfaction with them. Method: This was an endoscopist-blinded, prospective, randomized, controlled trial. A total of 224 patients (112 in each group) scheduled for outpatient colonoscopy met the criteria.They were randomized to either a low-residue diet consisting of white rice porridge with either fish, chicken or eggs before 8:00 followed by a clear-liquid diet (Group 1) or a low-residue diet consisting of the same food and drink, until 16:00 the day before colonoscopy(Group 2). All of them received 45 ml of sodium phosphate solution (Xubil ®) and three glasses of water (300 ml/glass) the evening before and the morning of the procedure. The cleansing efficacy of bowel preparation was rated according to the modified Rajawithi hospital bowel preparation score scale, patient satisfaction with bowel preparation was rated using Likert scale, and side effects of the 2 protocols was assessed using a patient questionnaire. Results: The cleansing efficacy between the two groups was significantly different (p=0.02). Satisfaction with bowel preparation and side effects were not different, except for the feeling of hunger in the first group (p=0.001). Conclusion: The low-residue diet consisting of white rice porridge with fish, chicken or eggs until 16:00 one day before colonoscopy achieved a better bowel-cleansing efficacy than the protocol consisting of clear liquid all day and rice porridge only before 8:00 one day before colonoscopy.

Keywords: bowel preparation, colonoscopy, sodium phosphate solution, nursing management

Procedia PDF Downloads 360
2085 Research of Actuators of Common Rail Injection Systems with the Use of LabVIEW on a Specially Designed Test Bench

Authors: G. Baranski, A. Majczak, M. Wendeker

Abstract:

Currently, the most commonly used solution to provide fuel to the diesel engines is the Common Rail system. Compared to previous designs, as a due to relatively simple construction and electronic control systems, these systems allow achieving favourable engine operation parameters with particular emphasis on low emission of toxic compounds into the atmosphere. In this system, the amount of injected fuel dose is strictly dependent on the course of parameters of the electrical impulse sent by the power amplifier power supply system injector from the engine controller. The article presents the construction of a laboratory test bench to examine the course of the injection process and the expense in storage injection systems. The test bench enables testing of injection systems with electromagnetically controlled injectors with the use of scientific engineering tools. The developed system is based on LabView software and CompactRIO family controller using FPGA systems and a real time microcontroller. The results of experimental research on electromagnetic injectors of common rail system, controlled by a dedicated National Instruments card, confirm the effectiveness of the presented approach. The results of the research described in the article present the influence of basic parameters of the electric impulse opening the electromagnetic injector on the value of the injected fuel dose. Acknowledgement: This work has been realized in the cooperation with The Construction Office of WSK ‘PZL-KALISZ’ S.A.’ and is part of Grant Agreement No. POIR.01.02.00-00-0002/15 financed by the Polish National Centre for Research and Development.

Keywords: fuel injector, combustion engine, fuel pressure, compression ignition engine, power supply system, controller, LabVIEW

Procedia PDF Downloads 99
2084 Trial of Resorbable versus Non-Resorbable Sutures for Traumatic Lacerations of the Face: A Demonstration of Maxillo-Facial Trainee Led Research

Authors: R. Botrugno, S Basyuni, G. Nugent, I. Jenkyn, A. Ferro, H. Bennett, C. Hjalmarsson, J. Chu, V. Santhanam

Abstract:

This trainee led randomised controlled trial (RCT) aims to assess various outcomes for resorbable versus non-resorbable sutures for traumatic lacerations to the face. Within this trial of resorbable versus non-resorbable sutures for traumatic lacerations of the face (TORNFace), patient recruitment was facilitated by trainees who were employed at an NHS University Teaching Hospital in the United Kingdom. The trainees received appropriate training prior to recruiting patients for the trial. This included the completion of a national research e-learning module and face-to-face training that was provided locally. The locally delivered training provided an understanding of the eligibility criteria for the trial and the consent process. Existing trainee skills were utilised involving clinical photography to record baseline data and delivering the intervention based on the treatment arm selected. Eligible patients who required primary closure of traumatic lacerations of the face were randomised into one of two treatment arms. These comprised of resorbable (vicryl rapide) or non-resorbable sutures (ethilon). Primarily the cosmetic outcome was assessed. Secondary outcomes included: complications rates, health care economics, and patient-reported outcomes. Remote follow-up of recruited patients utilised photographs of the facial laceration which had received the intervention. These took place at 1 week, 3 months and 6 months post-intervention. This study aims to demonstrate an example of trainee-led research within the specialty of oral and maxillofacial surgery. The available data for the randomised controlled trial will also be presented.

Keywords: laceration, suture, trauma, trial

Procedia PDF Downloads 105
2083 Perceptions of Research Staff on the Implementation of Each-B Study: A Randomised Controlled Trial

Authors: Laila Khawaja

Abstract:

In recent years, an increasing emphasis has been placed on measuring program implementation, in part because of the great variability in how complex interventions are delivered in real-life settings. There is an increased awareness that while conducting process evaluations, one should aim to identify and understand the complexities of intervention if they are to be used for future intervention development or the strategies needed to implement the same intervention in a different setting. Complex interventions are public health interventions that are not drugs or surgical procedures but have many potential active aspects of intervention. In this paper, process evaluations are aligned with MRC guidelines to identify contextual factors related to outcomes to assess the quality of implementation. This paper briefly discusses the perceptions of research team on the implementation of the intervention of ‘Engaging Adolescents in Changing Behaviour’ (EACH-B), a school-based complex intervention study aiming to improve diet and physical activity among adolescents aged 12-13 years. Through qualitative interviews and focus groups with 10 staff members, we aimed to understand their experiences and reflections on implementing the EACH-B trial delivered in 49 Schools around Hampshire, England. Data were uploaded into NVivo, and analysis was conducted using thematic analysis. The investigation revealed two overarching themes: (a) how the communication patterns with teachers were impacted during the delivery of implementation and (b) what were the team’s strategies to keep logistics aligned with the research process that impacted the overall implementation of the trial. The paper informs adaptation strategies used by the research team to establish and maintain effective communication with the teachers as well as the thoughtfulness of the team’s logistic strategy for the successful delivery of the trial.

Keywords: complex interventions, process evaluation, adaptation strategies, randomised controlled trial

Procedia PDF Downloads 38
2082 A Two Arm Double Parallel Randomized Controlled Trail of the Effects of Health Education Intervention on Insecticide Treated Nets Use and Its Practices among Pregnant Women Attending Antenatal Clinic: Study Protocol

Authors: Opara Monica, Suriani Ismail, Ahmad Iqmer Nashriq Mohd Nazan

Abstract:

The true magnitude of the mortality and morbidity attributable to malaria worldwide is, at best, a scientific guess, although it is not disputable that the greatest burden is in sub-Saharan Africa. Those at highest risk are children younger than 5 years and pregnant women, particularly primigravidae. Nationally, malaria remains the third leading cause of death and is still considered a major public health problem. Therefore, this study is aimed to assess the effectiveness of health education intervention on insecticide-treated net use and its practices among pregnant women attending antenatal clinics. Materials and Methods: This study will be an intervention study with two arms double parallel randomized controlled trial (blinded) to be conducted in 3 stages. The first stage will develop health belief model (HBM) program, while in the second stage, pregnant women will be recruited, assessed (baseline data), randomized into two arms of the study, and follow-up for six months. The third stage will evaluate the impact of the intervention on HBM and disseminate the findings. Data will be collected with the use of a structured questionnaire which will contain validated tools. The main outcome measurement will be the treatment effect using HBM, while data will be analysed using SPSS, version 22. Discussion: The study will contribute to the existing knowledge on hospital-based care programs for pregnant women in developing countries where the literature is scanty. It will generally give insight into the importance of HBM measurement in interventional studies on malaria and other related infectious diseases in this setting.

Keywords: malaria, health education, insecticide-treated nets, sub-Saharan Africa

Procedia PDF Downloads 86
2081 Association between Substance Use Disorder, PTSD and the Effectiveness of Collaborative Care for Depression in Primary Care: A Systematic Literature Search and Narrative Review

Authors: J. Raub, H. Schillok, L. Kaupe, C. Jung-Sievers, G. Pitschel-Walz, M. Bühner, J. Gensichen, F. D. Pokal-Gruppe

Abstract:

Introduction: In Germany, depression ranks among the top ten diseases with the highest disease burden and often occurs with comorbidities. Collaborative Care (CC), a concept developed in the United States for the primary care management of chronic diseases, has been identified as an efficient model for the treatment of depression in general medicine. A recent meta-analysis highlights research gaps regarding CC in patients with psychiatric multimorbidity. The highest prevalence of psychiatric comorbidities in depression is observed in anxiety disorders, post-traumatic stress disorder (PTSD), and substance use disorders. Methods: We conducted a literature search following the PRISMA guidelines with three components: Collaborative Care, Depression and randomized controlled trial on the common databases. We focused on the examination of psychiatric comorbidities in depression, specifically Posttraumatic Stress Disorder (PTSD) and Substance Use Disorder (SUD). Results: During the screening process, we identified nine relevant articles related to PTSD, the number of articles related to Substance Use Disorder (SUD) was ten. We examined a total of 8,634 individuals. Our literature review did not reveal any overall significant superiority of the Collaborative Care model compared to Usual Care in patients with depression with comorbid Substance Use Disorder (SUD) or Posttraumatic Stress Disorder (PTSD). Discussion: Five studies demonstrate a faster and statistically significant improvement in depression outcomes among patients with Substance Use Disorder (SUD) and Posttraumatic Stress Disorder (PTSD). Currently, several randomized controlled trials on the topic of Collaborative Care in depression with psychiatric comorbidity are ongoing, such as miCare, Claro and COMET.

Keywords: Depression, primary care, collaborative care, PTSD, Substance use Disorder

Procedia PDF Downloads 55
2080 Characterization of Tailings From Traditional Panning of Alluvial Gold Ore (A Case Study of Ilesa - Southwestern Nigeria Goldfield Tailings Dumps)

Authors: Olaniyi Awe, Adelana R. Adetunji, Abraham Adeleke

Abstract:

Field observation revealed a lot of artisanal gold mining activities in Ilesa gold belt of southwestern Nigeria. The possibility of alluvial and lode gold deposits in commercial quantities around this location is very high, as there are many resident artisanal gold miners who have been mining and trading alluvial gold ore for decades and to date in the area. Their major process of solid gold recovery from its ore is by gravity concentration using the convectional panning method. This method is simple to learn and fast to recover gold from its alluvial ore, but its effectiveness is based on rules of thumb and the artisanal miners' experience in handling gold ore panning tool while processing the ore. Research samples from five alluvial gold ore tailings dumps were collected and studied. Samples were subjected to particle size analysis and mineralogical and elemental characterization using X-Ray Diffraction (XRD) and Particle-Induced X-ray Emission (PIXE) methods, respectively. The results showed that the tailings were of major quartz in association with albite, plagioclase, mica, gold, calcite and sulphide minerals. The elemental composition analysis revealed a 15ppm of gold concentration in particle size fraction of -90 microns in one of the tailings dumps investigated. These results are significant. It is recommended that heaps of panning tailings should be further reprocessed using other gold recovery methods such as shaking tables, flotation and controlled cyanidation that can efficiently recover fine gold particles that were previously lost into the gold panning tailings. The tailings site should also be well controlled and monitored so that these heavy minerals do not find their way into surrounding water streams and rivers, thereby causing health hazards.

Keywords: gold ore, panning, PIXE, tailings, XRD

Procedia PDF Downloads 54
2079 Effect of Therapeutic Exercises with or without Positional Release Technique in Treatment of Chronic Mechanical Low Back Pain Patients a Randomized Controlled Trial

Authors: Ghada M. R. Koura, Mohamed N. Mohamed, Ahmed M. F. El Shiwi

Abstract:

Chronic mechanical Low back dysfunction (CMLBD) is the most common problem of the working-age population in modern industrial sociaty; it causes a substantial economic burden due to the wide use of medical services and absence from work. Aim of work: the aim of this study was to investigate the effect of positional release technique on patients with chronic mechanical low back pain. Materials and Methods: Thirty two patients from both sexes were diagnosed with CMLBP, aged 20 to 45 years and were divided randomly into two equal groups; sixteen patients each; group A (control group) received therapeutic exercises that include (Stretch and Strength exercises for back and abdominal muscles). Group B (experimental group) received therapeutic exercises with positional release technique; treatment was applied 3 days/week for 4 weeks. Pain was measured by Visual Analogue Scale, Lumbar range of motion was measured by Inclinometer and Functional disability was measured by Oswestry disability scale. Measurements were taken at two intervals pre-treatment and post-treatment. Results: Data obtained was analyzed via paired and unpaired t-Test. There were statistical differences between the 2 groups, where the experimental group showed greater improvement than control group. Conclusion: Positional release technique is considered as an effective treatment for reducing pain, functional disability and increasing lumbar range of motion in individuals with chronic mechanical low back pain.

Keywords: chronic mechanical low back pain, traditional physical therapy program, positional release technique, randomized controlled trial

Procedia PDF Downloads 566
2078 Layer-By-Layer Deposition of Poly(Ethylene Imine) Nanolayers on Polypropylene Nonwoven Fabric: Electrostatic and Thermal Properties

Authors: Dawid Stawski, Silviya Halacheva, Dorota Zielińska

Abstract:

The surface properties of many materials can be readily and predictably modified by the controlled deposition of thin layers containing appropriate functional groups and this research area is now a subject of widespread interest. The layer-by-layer (lbl) method involves depositing oppositely charged layers of polyelectrolytes onto the substrate material which are stabilized due to strong electrostatic forces between adjacent layers. This type of modification affords products that combine the properties of the original material with the superficial parameters of the new external layers. Through an appropriate selection of the deposited layers, the surface properties can be precisely controlled and readily adjusted in order to meet the requirements of the intended application. In the presented paper a variety of anionic (poly(acrylic acid)) and cationic (linear poly(ethylene imine), polymers were successfully deposited onto the polypropylene nonwoven using the lbl technique. The chemical structure of the surface before and after modification was confirmed by reflectance FTIR spectroscopy, volumetric analysis and selective dyeing tests. As a direct result of this work, new materials with greatly improved properties have been produced. For example, following a modification process significant changes in the electrostatic activity of a range of novel nanocomposite materials were observed. The deposition of polyelectrolyte nanolayers was found to strongly accelerate the loss of electrostatically generated charges and to increase considerably the thermal resistance properties of the modified fabric (the difference in T50% is over 20°C). From our results, a clear relationship between the type of polyelectrolyte layer deposited onto the flat fabric surface and the properties of the modified fabric was identified.

Keywords: layer-by-layer technique, polypropylene nonwoven, surface modification, surface properties

Procedia PDF Downloads 410
2077 A Meta-Analysis on the Efficacy and Safety of TRC101/Veverimer 6g/Day in Increasing Serum Bicarbonate Levels of Chronic Kidney Disease Patients with Metabolic Acidosis

Authors: Hazel Ann Gianelli Cu, Stephanie Co, Radcliff Cobankiat

Abstract:

Objectives: TRC101/Veverimer is an orally administered, non absorbed, sodium- and counterion-free hydrochloric acid binder for the treatment of metabolic acidosis associated with chronic kidney disease. The main objective of this study is to determine the efficacy of TRC 101/ Veverimer 6g/day in increasing serum bicarbonate levels of chronic kidney disease patients with metabolic acidosis. In this meta analysis, we also aim to look at safety outcomes, adverse effects and if the level of serum bicarbonate reached metabolic alkalosis when given TRC101/Veverimer. Methodology: Pubmed, Cochrane, Google Scholar and Science direct were used to search for randomized controlled trials about TRC101/Veverimer use in Chronic kidney disease patients with metabolic acidosis. Search strategy according to the Prisma checklist was done with evaluation of biases and synthesis of results using the Cochrane Review Manager software 5.4. Results: Two randomized controlled trials involving 371 chronic kidney disease patients were included in this study. Results show there was a significant increase in the serum bicarbonate level when given TRC101/Veverimer compared to the placebo. Both studies had a significant number of participants who completed the studies until the end. P value of <0.00001 was used in both studies with a confidence interval of 95%. Conclusion: TRC101/Veverimer 6g/day was shown to effectively and safely increase serum bicarbonate or achieve normalization in chronic kidney disease patients with metabolic acidosis as compared with a placebo. This was associated with delayed progression of kidney disease with improvement of physical functioning, however longer duration of future studies is ideal in order to assess further the long advantages and consequences of TRC 101/Veverimer.

Keywords: chronic kidney disease, metabolic acidosis, Veverimer, TRC101

Procedia PDF Downloads 170
2076 An Industrial Steady State Sequence Disorder Model for Flow Controlled Multi-Input Single-Output Queues in Manufacturing Systems

Authors: Anthony John Walker, Glen Bright

Abstract:

The challenge faced by manufactures, when producing custom products, is that each product needs exact components. This can cause work-in-process instability due to component matching constraints imposed on assembly cells. Clearing type flow control policies have been used extensively in mediating server access between multiple arrival processes. Although the stability and performance of clearing policies has been well formulated and studied in the literature, the growth in arrival to departure sequence disorder for each arriving job, across a serving resource, is still an area for further analysis. In this paper, a closed form industrial model has been formulated that characterizes arrival-to-departure sequence disorder through stable manufacturing systems under clearing type flow control policy. Specifically addressed are the effects of sequence disorder imposed on a downstream assembly cell in terms of work-in-process instability induced through component matching constraints. Results from a simulated manufacturing system show that steady state average sequence disorder in parallel upstream processing cells can be balanced in order to decrease downstream assembly system instability. Simulation results also show that the closed form model accurately describes the growth and limiting behavior of average sequence disorder between parts arriving and departing from a manufacturing system flow controlled via clearing policy.

Keywords: assembly system constraint, custom products, discrete sequence disorder, flow control

Procedia PDF Downloads 150
2075 Systematic Review of the Efficacy of Traditional Chinese Medicine in Parkinson Disease

Authors: Catarina Ramos Pereira, Jorge Rodrigues, Natália Oliveira, Jorge Machado, Maria Begoña Criado, Jorge Machado, Henri J. Greten

Abstract:

Background: Parkinson's disease is a multi-system neurodegenerative disorder characterized by motor and non-motor symptoms. To slow disorder progression, different treatment options are now available, but in most cases, these therapeutic strategies also involve the presence of important side effects. This has led many patients to pursue complementary therapies, such as acupuncture, to alleviate PD symptoms. Therefore, an update on the efficacy of this treatment for patients of PD is of great value. This work presents a systematic review of the efficacy of acupuncture treatments in relieving PD symptoms. Methods: EMBASE, Medline, Pubmed, Science Direct, The Cochrane Library, Cochrane Central Register of Controlled Trials (Central), and Scielo databases were systematically searched from January 2011 through July 2021. Randomized controlled trials (RCTs) published in English with all types of acupuncture treatment were included. The selection and analysis of the articles were conducted by two blinding authors through the Rayyan application. Results: 720 potentially relevant articles were identified; 52 RCTs met our inclusion criteria. After the exclusion of 35, we found 17 eligible. The included RCTs reported positive effects for acupuncture plus conventional treatment compared with conventional treatment alone in the UPDRS score. Conclusions: Additional evidence should be supported by rigorous methodological strategies. Although firm conclusions cannot be drawn, acupuncture treatment, in the framework of an interdisciplinary care team, appears to have positive effects on PD symptoms.

Keywords: systematic review, Parkinson disease, acupuncture, traditional Chinese medicine

Procedia PDF Downloads 109
2074 Hearing Conservation Program for Vector Control Workers: Short-Term Outcomes from a Cluster-Randomized Controlled Trial

Authors: Rama Krishna Supramanian, Marzuki Isahak, Noran Naqiah Hairi

Abstract:

Noise-induced hearing loss (NIHL) is one of the highest recorded occupational diseases, despite being preventable. Hearing Conservation Program (HCP) is designed to protect workers hearing and prevent them from developing hearing impairment due to occupational noise exposures. However, there is still a lack of evidence regarding the effectiveness of this program. The purpose of this study was to determine the effectiveness of a Hearing Conservation Program (HCP) in preventing or reducing audiometric threshold changes among vector control workers. This study adopts a cluster randomized controlled trial study design, with district health offices as the unit of randomization. Nine district health offices were randomly selected and 183 vector control workers were randomized to intervention or control group. The intervention included a safety and health policy, noise exposure assessment, noise control, distribution of appropriate hearing protection devices, training and education program and audiometric testing. The control group only underwent audiometric testing. Audiometric threshold changes observed in the intervention group showed improvement in the hearing threshold level for all frequencies except 500 Hz and 8000 Hz for the left ear. The hearing threshold changes range from 1.4 dB to 5.2 dB with largest improvement at higher frequencies mainly 4000 Hz and 6000 Hz. Meanwhile for the right ear, the mean hearing threshold level remained similar at 4000 Hz and 6000 Hz after 3 months of intervention. The Hearing Conservation Program (HCP) is effective in preserving the hearing of vector control workers involved in fogging activity as well as increasing their knowledge, attitude and practice towards noise-induced hearing loss (NIHL).

Keywords: adult, hearing conservation program, noise-induced hearing loss, vector control worker

Procedia PDF Downloads 126
2073 Development of Polylactic Acid Insert with a Cinnamaldehyde-Betacyclodextrin Complex for Cape Gooseberry (Physalis Peruviana L.) Packed

Authors: Gómez S. Jennifer, Méndez V. Camila, Moncayo M. Diana, Vega M. Lizeth

Abstract:

The cape gooseberry is a climacteric fruit; Colombia is one of the principal exporters in the world. The environmental condition of temperature and relative moisture decreases the titratable acidity and pH. These conditions and fruit maturation result in the fungal proliferation of Botrytis cinerea disease. Plastic packaging for fresh cape gooseberries was used for mechanical damage protection but created a suitable atmosphere for fungal growth. Beta-cyclodextrins are currently implemented as coatings for the encapsulation of hydrophobic compounds, for example, with bioactive compounds from essential oils such as cinnamaldehyde, which has a high antimicrobial capacity. However, it is a volatile substance. In this article, the casting method was used to obtain a polylactic acid (PLA) polymer film containing the beta-cyclodextrin-cinnamaldehyde inclusion complex, generating an insert that allowed the controlled release of the antifungal substance in packed cape gooseberries to decrease contamination by Botrytis cinerea in a latent state during storage. For the encapsulation technique, three ratios for the cinnamaldehyde: beta-cyclodextrin inclusion complex were proposed: (25:75), (40:60), and (50:50). Spectrophotometry, colorimetry in L*a*b* coordinate space and scanning electron microscopy (SEM) were made for the complex characterization. Subsequently, two ratios of tween and water (40:60) and (50:50) were used to obtain the polylactic acid (PLA) film. To determine mechanical and physical parameters of colourimetry in L*a*b* coordinate space, atomic force microscopy and stereoscopy were done to determine the transparency and flexibility of the film; for both cases, Statgraphics software was used to determine the best ratio in each of the proposed phases, where for encapsulation it was (50:50) with an encapsulation efficiency of 65,92%, and for casting the ratio (40:60) obtained greater transparency and flexibility that permitted its incorporation into the polymeric packaging. A liberation assay was also developed under ambient temperature conditions to evaluate the concentration of cinnamaldehyde inside the packaging through gas chromatography for three weeks. It was found that the insert had a controlled release. Nevertheless, a higher cinnamaldehyde concentration is needed to obtain the minimum inhibitory concentration for the fungus Botrytis cinerea (0.2g/L). The homogeneity of the cinnamaldehyde gas phase inside the packaging can be improved by considering other insert configurations. This development aims to impact emerging food preservation technologies with the controlled release of antifungals to reduce the affectation of the physico-chemical and sensory properties of the fruit as a result of contamination by microorganisms in the postharvest stage.

Keywords: antifungal, casting, encapsulation, postharvest

Procedia PDF Downloads 46
2072 The Effectiveness of Sleep Behavioral Interventions during the Third Trimester of Pregnancy on Sleep Quality and Postpartum Depression in a Randomized Clinical Controlled Trial

Authors: Somaye Ghafarpour, Kamran Yazdanbakhsh, Mohamad Reza Zarbakhsh, Simin Hosseinian, Samira Ghafarpour

Abstract:

Unsatisfactory sleep quality is one of the most common complications of pregnancy, which can predispose mothers to postpartum depression, requiring implementing effective psychological interventions to prevent and modify behaviors accentuating sleep problems. This study was a randomized clinical controlled trial with a pre-test/post-test design aiming to investigate the effectiveness of sleep behavioral interventions during the third trimester of pregnancy on sleep quality and postpartum depression. A total of 50 pregnant mothers in the 26-30 weeks of pregnancy suffering from sleep problems (based on the score obtained from the Pittsburgh Sleep Questionnaire) were randomized into two groups (control and intervention, n= 25 per group). The data were collected using interviews, the Pittsburgh Sleep Quality Index (PSQI), and the Edinburgh Postnatal Depression Scale (EPDS) were used. The participants in the intervention group received eight 60-minute sessions of combinational training for behavioral therapy techniques. At the end of the intervention and four weeks after delivery, sleep quality and postpartum depression were evaluated. Considering that the Kolmogorov Smirnov test confirmed the normal distribution of the data, the independent t-test and analysis of covariance were used to analyze the data, showing that the behavioral interventions were effective on the overall sleep quality after delivery (p=0.001); however, no statistically significant effects were observed on postpartum depression, the sub-scales of sleep disorders, and daily functioning (p>0.05). Considering the potential effectiveness of behavioral interventions in improving sleep quality and alleviating insomnia symptoms, it is recommended to implement such measures as an effective intervention to prevent or treat these problems during prenatal and postnatal periods.

Keywords: behavioral interventions, sleep quality, postpartum depression, pregnancy, delivery

Procedia PDF Downloads 46
2071 Multi-Objective Optimal Design of a Cascade Control System for a Class of Underactuated Mechanical Systems

Authors: Yuekun Chen, Yousef Sardahi, Salam Hajjar, Christopher Greer

Abstract:

This paper presents a multi-objective optimal design of a cascade control system for an underactuated mechanical system. Cascade control structures usually include two control algorithms (inner and outer). To design such a control system properly, the following conflicting objectives should be considered at the same time: 1) the inner closed-loop control must be faster than the outer one, 2) the inner loop should fast reject any disturbance and prevent it from propagating to the outer loop, 3) the controlled system should be insensitive to measurement noise, and 4) the controlled system should be driven by optimal energy. Such a control problem can be formulated as a multi-objective optimization problem such that the optimal trade-offs among these design goals are found. To authors best knowledge, such a problem has not been studied in multi-objective settings so far. In this work, an underactuated mechanical system consisting of a rotary servo motor and a ball and beam is used for the computer simulations, the setup parameters of the inner and outer control systems are tuned by NSGA-II (Non-dominated Sorting Genetic Algorithm), and the dominancy concept is used to find the optimal design points. The solution of this problem is not a single optimal cascade control, but rather a set of optimal cascade controllers (called Pareto set) which represent the optimal trade-offs among the selected design criteria. The function evaluation of the Pareto set is called the Pareto front. The solution set is introduced to the decision-maker who can choose any point to implement. The simulation results in terms of Pareto front and time responses to external signals show the competing nature among the design objectives. The presented study may become the basis for multi-objective optimal design of multi-loop control systems.

Keywords: cascade control, multi-Loop control systems, multiobjective optimization, optimal control

Procedia PDF Downloads 126
2070 Design of an Automatic Bovine Feeding Machine

Authors: Huseyin A. Yavasoglu, Yusuf Ziya Tengiz, Ali Göksenli

Abstract:

In this study, an automatic feeding machine for different type and class of bovine animals is designed. Daily nutrition of a bovine consists of grass, corn, straw, silage, oat, wheat and different vitamins and minerals. The amount and mixture amount of each of the nutrition depends on different parameters of the bovine. These parameters are; age, sex, weight and maternity of the bovine, also outside temperature. The problem in a farm is to constitute the correct mixture and amount of nutrition for each animal. Faulty nutrition will cause an insufficient feeding of the animal concluding in an unhealthy bovine. To solve this problem, a new automatic feeding machine is designed. Travelling of the machine is performed by four tires, which is pulled by a tractor. The carrier consists of eight bins, which each of them carries a nutrition type. Capacity of each unit is 250 kg. At the bottom of each chamber is a sensor measuring the weight of the food inside. A funnel is at the bottom of each chamber by which open/close function is controlled by a valve. Each animal will carry a RFID tag including ID on its ear. A receiver on the feeding machine will read this ID and by given previous information by the operator (veterinarian), the system will detect the amount of each nutrition unit which will be given to the selected animal for feeding. In the system, each bin will open its exit gate by the help of the valve under the control of PLC (Programmable Logic Controller). The amount of each nutrition type will be controlled by measuring the open/close time. The exit canals of the bins are collected in a reservoir. To achieve a homogenous nitration, the collected feed will be mixed by a worm gear. Further the mixture will be transported by a help of a funnel to the feeding unit of the animal. The feeding process can be performed in 100 seconds. After feeding of the animal, the tractor pulls the travelling machine to the next animal. By the help of this system animals can be feeded by right amount and mixture of nutrition

Keywords: bovine, feeding, nutrition, transportation, automatic

Procedia PDF Downloads 313
2069 Greenhouse Controlled with Graphical Plotting in Matlab

Authors: Bruno R. A. Oliveira, Italo V. V. Braga, Jonas P. Reges, Luiz P. O. Santos, Sidney C. Duarte, Emilson R. R. Melo, Auzuir R. Alexandria

Abstract:

This project aims to building a controlled greenhouse, or for better understanding, a structure where one can maintain a given range of temperature values (°C) coming from radiation emitted by an incandescent light, as previously defined, characterizing as a kind of on-off control and a differential, which is the plotting of temperature versus time graphs assisted by MATLAB software via serial communication. That way it is possible to connect the stove with a computer and monitor parameters. In the control, it was performed using a PIC 16F877A microprocessor which enabled convert analog signals to digital, perform serial communication with the IC MAX232 and enable signal transistors. The language used in the PIC's management is Basic. There are also a cooling system realized by two coolers 12V distributed in lateral structure, being used for venting and the other for exhaust air. To find out existing temperature inside is used LM35DZ sensor. Other mechanism used in the greenhouse construction was comprised of a reed switch and a magnet; their function is in recognition of the door position where a signal is sent to a buzzer when the door is open. Beyond it exist LEDs that help to identify the operation which the stove is located. To facilitate human-machine communication is employed an LCD display that tells real-time temperature and other information. The average range of design operating without any major problems, taking into account the limitations of the construction material and structure of electrical current conduction, is approximately 65 to 70 ° C. The project is efficient in these conditions, that is, when you wish to get information from a given material to be tested at temperatures not as high. With the implementation of the greenhouse automation, facilitating the temperature control and the development of a structure that encourages correct environment for the most diverse applications.

Keywords: greenhouse, microcontroller, temperature, control, MATLAB

Procedia PDF Downloads 376
2068 Antibacterial Nanofibrous Film Encapsulated with 4-terpineol/β-cyclodextrin Inclusion Complexes: Relative Humidity-Triggered Release and Shrimp Preservation Application

Authors: Chuanxiang Cheng, Tiantian Min, Jin Yue

Abstract:

Antimicrobial active packaging enables extensive biological effects to improve food safety. However, the efficacy of antimicrobial packaging hinges on factors including the diffusion rate of the active agent toward the food surface, the initial content in the antimicrobial agent, and the targeted food shelf life. Among the possibilities of antimicrobial packaging design, an interesting approach involves the incorporation of volatile antimicrobial agents into the packaging material. In this case, the necessity for direct contact between the active packaging material and the food surface is mitigated, as the antimicrobial agent exerts its action through the packaging headspace atmosphere towards the food surface. However, it still remains difficult to achieve controlled and precise release of bioactive compounds to the specific target location with required quantity in food packaging applications. Remarkably, the development of stimuli-responsive materials for electrospinning has introduced the possibility of achieving controlled release of active agents under specific conditions, thereby yielding enduring biological effects. Relative humidity (RH) for the storage of food categories such as meat and aquatic products typically exceeds 90%. Consequently, high RH can be used as an abiotic trigger for the release of active agents to prevent microbial growth. Hence, a novel RH - responsive polyvinyl alcohol/chitosan (PVA/CS) composite nanofibrous film incorporated with 4-terpineol/β-cyclodextrin inclusion complexes (4-TA@β-CD ICs) was engineered by electrospinning that can be deposited as a functional packaging materials. The characterization results showed the thermal stability of the films was enhanced after the incorporation due to the hydrogen bonds between ICs and polymers. Remarkably, the 4 wt% 4-TA@β-CD ICs/PVA/CS film exhibited enhanced crystallinity, moderate hydrophilic (Water contact angle of 81.53°), light barrier property (Transparency of 1.96%) and water resistance (Water vapor permeability of 3.17 g mm/m2 h kPa). Moreover, this film also showed optimized mechanical performance with a Young’s modulus of 11.33 MPa, a tensile strength of 19.99 MPa and an elongation at break of 4.44 %. Notably, the antioxidant and antibacterial properties of this packaging material were significantly improved. The film demonstrated the half-inhibitory concentrations (IC50) values of 87.74% and 85.11% for scavenging 2,2-diphenyl-1-picrylhydrazyl (DPPH) and 2, 2′-azinobis (3-ethylbenzothiazoline-6-sulfonic) (ABTS) free radicals, respectively, in addition to an inhibition efficiency of 65% against Shewanella putrefaciens, the characteristic bacteria in aquatic products. Most importantly, the film achieved controlled release of 4-TA under high 98% RH by inducing the plasticization of polymers caused by water molecules, swelling of polymer chains, and destruction of hydrogen bonds within the cyclodextrin inclusion complex. Consequently, low relative humidity is suitable for the preservation of nanofibrous film, while high humidity conditions typical in fresh food packaging environments effectively stimulated the release of active compounds in the film. This film with a long-term antimicrobial effect successfully extended the shelf life of Litopenaeus vannamei shrimp to 7 days at 4 °C. This attractive design could pave the way for the development of new food packaging materials.

Keywords: controlled release, electrospinning, nanofibrous film, relative humidity–responsive, shrimp preservation

Procedia PDF Downloads 31
2067 The Effect of Pregabalin on Postoperative Pain after Anterior Cruciate Ligament Reconstruction: A Systematic Review of Randomized Clinical Trials

Authors: Emad Kouhestani

Abstract:

Background: Despite the enormous success of anterior cruciate ligament (ACL) reconstruction, acute neuropathic pain can develop postoperatively and is both distressing and difficult to treat once established. Pregabalin, as an anticonvulsant agent that selectively affects the nociceptive process, has been used as a pain relief agent. The purpose of this systematic review of randomized controlled trials (RCTs) was to evaluate the pain control effect of pregabalin versus placebo after ACL reconstruction. Method: A search of the literature was performed from inception to June 2022, using PubMed, Scopus, Google Scholar, Web of Science, Cochrane, and EBSCO. Studies considered for inclusion were RCTs that reported relevant outcomes (postoperative pain scores, or cumulative opioid consumption, adverse events) following the administration of pregabalin in patients undergoing ACL reconstruction. Result: Five placebo-controlled RCTs involving 272 participants met the inclusion criteria. 75 mg and 150 mg of oral pregabalin were used in included trials. Two studies used a single dose of pregabalin one hour before anesthesia induction. Two studies used pregabalin 1 hour before anesthesia induction and 12 hours after. One study used daily pregabalin 7 days before and 7 days after surgery. Out of five papers, three papers found significantly lower pain intensity and cumulative opioid consumption in the pregabalin group compared with the placebo group. However, a decrease in pain scores was found in all trials. Pregabalin administration was associated with dizziness and nausea. Conclusion: The use of pregabalin may be a valuable asset in pain management after ACL reconstruction. However, future studies with larger sample sizes and longer follow-up periods are required.

Keywords: pregabalin, anterior cruciate ligament, postoperative pain, clinical trial

Procedia PDF Downloads 57
2066 Prototype Development of ARM-7 Based Embedded Controller for Packaging Machine

Authors: Jeelka Ray

Abstract:

Survey of the papers revealed that there is no practical design available for packaging machine based on Embedded system, so the need arose for the development of the prototype model. In this paper, author has worked on the development of an ARM7 based Embedded Controller for controlling the sequence of packaging machine. The unit is made user friendly with TFT and Touch Screen implementing human machine interface (HMI). The different system components are briefly discussed, followed by a description of the overall design. The major functions which involve bag forming, sealing temperature control, fault detection, alarm, animated view on the home screen when the machine is working as per different parameters set makes the machine performance more successful. LPC2478 ARM 7 Embedded Microcontroller controls the coordination of individual control function modules. In back gone days, these machines were manufactured with mechanical fittings. Later on, the electronic system replaced them. With the help of ongoing technologies, these mechanical systems were controlled electronically using Microprocessors. These became the backbone of the system which became a cause for the updating technologies in which the control was handed over to the Microcontrollers with Servo drives for accurate positioning of the material. This helped to maintain the quality of the products. Including all, RS 485 MODBUS Communication technology is used for synchronizing AC Drive & Servo Drive. These all concepts are operated either manually or through a Graphical User Interface. Automatic tuning of heaters, sealers and their temperature is controlled using Proportional, Integral and Derivation loops. In the upcoming latest technological world, the practical implementation of the above mentioned concepts is really important to be in the user friendly environment. Real time model is implemented and tested on the actual machine and received fruitful results.

Keywords: packaging machine, embedded system, ARM 7, micro controller, HMI, TFT, touch screen, PID

Procedia PDF Downloads 248
2065 Improved Thermal Comfort and Sensation with Occupant Control of Ceiling Personalized Ventilation System: A Lab Study

Authors: Walid Chakroun, Sorour Alotaibi, Nesreen Ghaddar, Kamel Ghali

Abstract:

This study aims at determining the extent to which occupant control of microenvironment influences, improves thermal sensation and comfort, and saves energy in spaces equipped with ceiling personalized ventilation (CPV) system assisted by chair fans (CF) and desk fans (DF) in 2 experiments in a climatic chamber equipped with two-station CPV systems, one that allows control of fan flow rate and the other is set to the fan speed of the selected participant in control. Each experiment included two participants each entering the cooled space from transitional environment at a conventional mixed ventilation (MV) at 24 °C. For CPV diffuser, fresh air was delivered at a rate of 20 Cubic feet per minute (CFM) and a temperature of 16 °C while the recirculated air was delivered at the same temperature but at a flow rate 150 CFM. The macroclimate air of the space was at 26 °C. The full speed flow rates for both the CFs and DFs were at 5 CFM and 20 CFM, respectively. Occupant 1 was allowed to operate the CFs or the DFs at (1/3 of the full speed, 2/3 of the full speed, and the full speed) while occupant 2 had no control on the fan speed and their fan speed was selected by occupant 1. Furthermore, a parametric study was conducted to study the effect of increasing the fresh air flow rate on the occupants’ thermal comfort and whole body sensations. The results showed that most occupants in the CPV+CFs, who did not control the CF flow rate, felt comfortable 6 minutes. The participants, who controlled the CF speeds, felt comfortable in around 24 minutes because they were preoccupied with the CFs. For the DF speed control experiments, most participants who did not control the DFs felt comfortable within the first 8 minutes. Similarly to the CPV+CFs, the participants who controlled the DF flow rates felt comfortable at around 26 minutes. When the CPV system was either supported by CFs or DFs, 93% of participants in both cases reached thermal comfort. Participants in the parametric study felt more comfortable when the fresh air flow rate was low, and felt cold when as the flow rate increased.

Keywords: PMV, thermal comfort, thermal environment, thermal sensation

Procedia PDF Downloads 232
2064 Electrophoretic Deposition of Ultrasonically Synthesized Nanostructured Conducting Poly(o-phenylenediamine)-Co-Poly(1-naphthylamine) Film for Detection of Glucose

Authors: Vaibhav Budhiraja, Chandra Mouli Pandey

Abstract:

The ultrasonic synthesis of nanostructured conducting copolymer is an effective technique to synthesize polymer with desired chemical properties. This tailored nanostructure, shows tremendous improvement in sensitivity and stability to detect a variety of analytes. The present work reports ultrasonically synthesized nanostructured conducting poly(o-phenylenediamine)-co-poly(1-naphthylamine) (POPD-co-PNA). The synthesized material has been characterized using Fourier transform infrared spectroscopy (FTIR), ultraviolet-visible spectroscopy, transmission electron microscopy, X-ray diffraction and cyclic voltammetry. FTIR spectroscopy confirmed random copolymerization, while UV-visible studies reveal the variation in polaronic states upon copolymerization. High crystallinity was achieved via ultrasonic synthesis which was confirmed by X-ray diffraction, and the controlled morphology of the nanostructures was confirmed by transmission electron microscopy analysis. Cyclic voltammetry shows that POPD-co-PNA has rather high electrochemical activity. This behavior was explained on the basis of variable orientations adopted by the conducting polymer chains. The synthesized material was electrophoretically deposited at onto indium tin oxide coated glass substrate which is used as cathode and parallel platinum plate as the counter electrode. The fabricated bioelectrode was further used for detection of glucose by crosslinking of glucose oxidase in the PODP-co-PNA film. The bioelectrode shows a surface-controlled electrode reaction with the electron transfer coefficient (α) of 0.72, charge transfer rate constant (ks) of 21.77 s⁻¹ and diffusion coefficient 7.354 × 10⁻¹⁵ cm²s⁻¹.

Keywords: conducting, electrophoretic, glucose, poly (o-phenylenediamine), poly (1-naphthylamine), ultrasonic

Procedia PDF Downloads 119
2063 Storage System Validation Study for Raw Cocoa Beans Using Minitab® 17 and R (R-3.3.1)

Authors: Anthony Oppong Kyekyeku, Sussana Antwi-Boasiako, Emmanuel De-Graft Johnson Owusu Ansah

Abstract:

In this observational study, the performance of a known conventional storage system was tested and evaluated for fitness for its intended purpose. The system has a scope extended for the storage of dry cocoa beans. System sensitivity, reproducibility and uncertainties are not known in details. This study discusses the system performance in the context of existing literature on factors that influence the quality of cocoa beans during storage. Controlled conditions were defined precisely for the system to give reliable base line within specific established procedures. Minitab® 17 and R statistical software (R-3.3.1) were used for the statistical analyses. The approach to the storage system testing was to observe and compare through laboratory test methods the quality of the cocoa beans samples before and after storage. The samples were kept in Kilner jars and the temperature of the storage environment controlled and monitored over a period of 408 days. Standard test methods use in international trade of cocoa such as the cut test analysis, moisture determination with Aqua boy KAM III model and bean count determination were used for quality assessment. The data analysis assumed the entire population as a sample in order to establish a reliable baseline to the data collected. The study concluded a statistically significant mean value at 95% Confidence Interval (CI) for the performance data analysed before and after storage for all variables observed. Correlational graphs showed a strong positive correlation for all variables investigated with the exception of All Other Defect (AOD). The weak relationship between the before and after data for AOD had an explained variability of 51.8% with the unexplained variability attributable to the uncontrolled condition of hidden infestation before storage. The current study concluded with a high-performance criterion for the storage system.

Keywords: benchmarking performance data, cocoa beans, hidden infestation, storage system validation

Procedia PDF Downloads 143
2062 The Optimization of Topical Antineoplastic Therapy Using Controlled Release Systems Based on Amino-functionalized Mesoporous Silica

Authors: Lacramioara Ochiuz, Aurelia Vasile, Iulian Stoleriu, Cristina Ghiciuc, Maria Ignat

Abstract:

Topical administration of chemotherapeutic agents (eg. carmustine, bexarotene, mechlorethamine etc.) in local treatment of cutaneous T-cell lymphoma (CTCL) is accompanied by multiple side effects, such as contact hypersensitivity, pruritus, skin atrophy or even secondary malignancies. A known method of reducing the side effects of anticancer agent is the development of modified drug release systems using drug incapsulation in biocompatible nanoporous inorganic matrices, such as mesoporous MCM-41 silica. Mesoporous MCM-41 silica is characterized by large specific surface, high pore volume, uniform porosity, and stable dispersion in aqueous medium, excellent biocompatibility, in vivo biodegradability and capacity to be functionalized with different organic groups. Therefore, MCM-41 is an attractive candidate for a wide range of biomedical applications, such as controlled drug release, bone regeneration, protein immobilization, enzymes, etc. The main advantage of this material lies in its ability to host a large amount of the active substance in uniform pore system with adjustable size in a mesoscopic range. Silanol groups allow surface controlled functionalization leading to control of drug loading and release. This study shows (I) the amino-grafting optimization of mesoporous MCM-41 silica matrix by means of co-condensation during synthesis and post-synthesis using APTES (3-aminopropyltriethoxysilane); (ii) loading the therapeutic agent (carmustine) obtaining a modified drug release systems; (iii) determining the profile of in vitro carmustine release from these systems; (iv) assessment of carmustine release kinetics by fitting on four mathematical models. Obtained powders have been described in terms of structure, texture, morphology thermogravimetric analysis. The concentration of the therapeutic agent in the dissolution medium has been determined by HPLC method. In vitro dissolution tests have been done using cell Enhancer in a 12 hours interval. Analysis of carmustine release kinetics from mesoporous systems was made by fitting to zero-order model, first-order model Higuchi model and Korsmeyer-Peppas model, respectively. Results showed that both types of highly ordered mesoporous silica (amino grafted by co-condensation process or post-synthesis) are thermally stable in aqueous medium. In what regards the degree of loading and efficiency of loading with the therapeutic agent, there has been noticed an increase of around 10% in case of co-condensation method application. This result shows that direct co-condensation leads to even distribution of amino groups on the pore walls while in case of post-synthesis grafting many amino groups are concentrated near the pore opening and/or on external surface. In vitro dissolution tests showed an extended carmustine release (more than 86% m/m) both from systems based on silica functionalized directly by co-condensation and after synthesis. Assessment of carmustine release kinetics revealed a release through diffusion from all studied systems as a result of fitting to Higuchi model. The results of this study proved that amino-functionalized mesoporous silica may be used as a matrix for optimizing the anti-cancer topical therapy by loading carmustine and developing prolonged-release systems.

Keywords: carmustine, silica, controlled, release

Procedia PDF Downloads 228
2061 Comparison of Statins Dose Intensity on HbA1c Control in Outpatients with Type 2 Diabetes: A Prospective Cohort Study

Authors: Mohamed A. Hammad, Dzul Azri Mohamed Noor, Syed Azhar Syed Sulaiman, Ahmed A. Khamis, Abeer Kharshid, Nor Azizah Aziz

Abstract:

The effect of statins dose intensity (SDI) on glycemic control in patients with existing diabetes is unclear. Also, there are many contradictory findings were reported in the literature; thus, it is limiting the possibility to draw conclusions. This project was designed to compare the effect of SDI on glycated hemoglobin (HbA1c%) control in outpatients with Type 2 diabetes in the endocrine clinic at Hospital Pulau Pinang, Malaysia, between July 2015 and August 2016. A prospective cohort study was conducted, where records of 345 patients with Type 2 diabetes (Moderate-SDI group 289 patients and high-SDI cohort 56 patients) were reviewed to identify demographics and laboratory tests. The target of glycemic control (HbA1c < 7% for patient < 65 years, and < 8% for patient ≥ 65 years) was estimated, and the results were presented as descriptive statistics. From 289 moderate-SDI cohorts with a mean age of 57.3 ± 12.4 years, only 86 (29.8%) cases were shown to have controlled glycemia, while there were 203 (70.2%) cases with uncontrolled glycemia with confidence interval (CI) of 95% (6.2–10.8). On the other hand, the high-SDI group of 56 patients with Type 2 diabetes with a mean age 57.7±12.4 years is distributed among 11 (19.6%) patients with controlled diabetes, and 45 (80.4%) of them had uncontrolled glycemia, CI: 95% (7.1–11.9). The study has demonstrated that the relative risk (RR) of uncontrolled glycemia in patients with Type 2 diabetes that used high-SDI is 1.15, and the excessive relative risk (ERR) is 15%. The absolute risk (AR) is 10.2%, and the number needed to harm (NNH) is 10. Outpatients with Type 2 diabetes who use high-SDI of statin have a higher risk of uncontrolled glycemia than outpatients who had been treated with a moderate-SDI.

Keywords: cohort study, diabetes control, dose intensity, HbA1c, Malaysia, statin, type 2 diabetes mellitus, uncontrolled glycemia

Procedia PDF Downloads 275
2060 Study on Shifting Properties of CVT Rubber V-belt

Authors: Natsuki Tsuda, Kiyotaka Obunai, Kazuya Okubo, Hideyuki Tashiro, Yoshinori Yamaji, Hideyuki Kato

Abstract:

The objective of this study is to investigate the effect of belt stiffness on the performance of the CVT unit, such as the required pulley thrust force and the ratio coverage. The CVT unit consists of the V-grooved pulleys and the rubber CVT belt. The width of the driving pulley groove was controlled by the stepper motor, while that of the driven pulley was controlled by the hydraulic pressure. The generated mechanical power on the motor was transmitted from the driving axis to the driven axis through the CVT unit. The rotational speed and the transmitting torque of both axes were measured by the tachometers and the torque meters attached with these axes, respectively. The transmitted, mechanical power was absorbed by the magnetic powder brake. The thrust force acting on both pulleys and the force between both shafts were measured by the load cell. The back face profile of the rubber CVT belt along with width direction was measured by the 2-dimensional laser displacement meter. This paper found that when the stiffness of the rubber CVT belt in the belt width direction was reduced, the thrust force required for shifting was reduced. Moreover, when the stiffness of the rubber CVT belt in the belt width direction was reduced, the ratio coverage of the CVT unit was reduced. Due to the decrement of stiffness in belt width direction, the excessive concave deformation of belt in pulley groove was confirmed. Because of this excessive concave deformation, apparent wrapping radius of belt would have been reduced. Proposed model could be effectively estimated the difference of ratio coverage due to concave deformation. The proposed model could also be utilized for designing the rubber CVT belt with optimal bending stiffness in width direction.

Keywords: CVT, countinuously variable transmission, rubber, belt stiffness, transmission

Procedia PDF Downloads 118
2059 Evaluating Structural Crack Propagation Induced by Soundless Chemical Demolition Agent Using an Energy Release Rate Approach

Authors: Shyaka Eugene

Abstract:

The efficient and safe demolition of structures is a critical challenge in civil engineering and construction. This study focuses on the development of optimal demolition strategies by investigating the crack propagation behavior in beams induced by soundless cracking agents. It is commonly used in controlled demolition and has gained prominence due to its non-explosive and environmentally friendly nature. This research employs a comprehensive experimental and computational approach to analyze the crack initiation, propagation, and eventual failure in beams subjected to soundless cracking agents. Experimental testing involves the application of various cracking agents under controlled conditions to understand their effects on the structural integrity of beams. High-resolution imaging and strain measurements are used to capture the crack propagation process. In parallel, numerical simulations are conducted using advanced finite element analysis (FEA) techniques to model crack propagation in beams, considering various parameters such as cracking agent composition, loading conditions, and beam properties. The FEA models are validated against experimental results, ensuring their accuracy in predicting crack propagation patterns. The findings of this study provide valuable insights into optimizing demolition strategies, allowing engineers and demolition experts to make informed decisions regarding the selection of cracking agents, their application techniques, and structural reinforcement methods. Ultimately, this research contributes to enhancing the safety, efficiency, and sustainability of demolition practices in the construction industry, reducing environmental impact and ensuring the protection of adjacent structures and the surrounding environment.

Keywords: expansion pressure, energy release rate, soundless chemical demolition agent, crack propagation

Procedia PDF Downloads 33
2058 Challenging the Traditional Practice of Continuous Abscess Cavity Packing – A Single Center, Single Blind Randomized Controlled Trial

Authors: Lakmali Anthony, Bushra Oathman, Anshini Jain, Raaj Chandra

Abstract:

Introduction: Abscesses are traditionally treated by incision and drainage with the packing of the residual abscess cavity until healing. This method requires regular visits from community nurses for continuous wound packing upon discharge from the hospital and causes considerable patient discomfort. Whether abscess cavity packing offers any advantage over non-packing has not yet been adequately studied to the best of our knowledge. This study aims to determine if there are differences in clinical outcomes of time to healing, fistula formation and recurrence of abscess between abscess cavity packing vs. non-packing groups. Methods: This study was a single-center, single-blind, randomized controlled trial where patients were randomized into packing and non-packing arms. All patients over 18 years presenting to Eastern Health with an abscess requiring incision and drainage in the theatre were invited to participate. Those with underlying conditions that cause recurrent abscesses were excluded. Data were collected from December 2018 to April 2020. Results: There were 63 patients who had abscesses treated with incision and drainage that were enrolled in the study, 52 of which were suitable for analysis. Demographic characteristics were similar in both groups. The packing group had a significantly longer time to heal compared to the non-packing group. Rates of fistula formation and recurrence of abscess were low and there were no statistically significant differences between groups. The packing group had more patients with delayed healing (defined as >60 days) and required more follow-up visits compared to the non-packing group. Conclusion: This pilot study indicates that abscesses can not only be managed safely with incision and drainage alone without the need for continuous abscess cavity packing but also that non-packing may offer clinical benefits to patients with earlier healing of abscesses compared to continuous cavity packing.

Keywords: abscess packing, subcutaneous, perianal, pilonidal

Procedia PDF Downloads 45