25924 Comparison of Radiation Dosage and Image Quality: Digital Breast Tomosynthesis vs. Full-Field Digital Mammography

Authors: Okhee Woo

Abstract:

Purpose: With increasing concern of individual radiation exposure doses, studies analyzing radiation dosage in breast imaging modalities are required. Aim of this study is to compare radiation dosage and image quality between digital breast tomosynthesis (DBT) and full-field digital mammography (FFDM). Methods and Materials: 303 patients (mean age 52.1 years) who studied DBT and FFDM were retrospectively reviewed. Radiation dosage data were obtained by radiation dosage scoring and monitoring program: Radimetrics (Bayer HealthCare, Whippany, NJ). Entrance dose and mean glandular doses in each breast were obtained in both imaging modalities. To compare the image quality of DBT with two-dimensional synthesized mammogram (2DSM) and FFDM, 5-point scoring of lesion clarity was assessed and the better modality between the two was selected. Interobserver performance was compared with kappa values and diagnostic accuracy was compared using McNemar test. The parameters of radiation dosages (entrance dose, mean glandular dose) and image quality were compared between two modalities by using paired t-test and Wilcoxon rank sum test. Results: For entrance dose and mean glandular doses for each breasts, DBT had lower values compared with FFDM (p-value < 0.0001). Diagnostic accuracy did not have statistical difference, but lesion clarity score was higher in DBT with 2DSM and DBT was chosen as a better modality compared with FFDM. Conclusion: DBT showed lower radiation entrance dose and also lower mean glandular doses to both breasts compared with FFDM. Also, DBT with 2DSM had better image quality than FFDM with similar diagnostic accuracy, suggesting that DBT may have a potential to be performed as an alternative to FFDM.

Keywords: radiation dose, DBT, digital mammography, image quality

Procedia PDF Downloads 349
25923 Cardiac Pacemaker in a Patient Undergoing Breast Radiotherapy-Multidisciplinary Approach

Authors: B. Petrović, M. Petrović, L. Rutonjski, I. Djan, V. Ivanović

Abstract:

Objective: Cardiac pacemakers are very sensitive to radiotherapy treatment from two sources: electromagnetic influence from the medical linear accelerator producing ionizing radiation- influencing electronics within the pacemaker, and the absorption of dose to the device. On the other hand, patients with cardiac pacemakers at the place of a tumor are rather rare, and single clinic hardly has experience with the management of such patients. The widely accepted international guidelines for management of radiation oncology patients recommend that these patients should be closely monitored and examined before, during and after radiotherapy treatment by cardiologist, and their device and condition followed up. The number of patients having both cancer and pacemaker, is growing every year, as both cancer incidence, as well as cardiac diseases incidence, are inevitably growing figures. Materials and methods: Female patient, age 69, was diagnozed with valvular cardiomyopathy and got implanted a pacemaker in 2005 and prosthetic mitral valve in 1993 (cancer was diagnosed in 2012). She was stable cardiologically and came to radiation therapy department with the diagnosis of right breast cancer, with the tumor in upper lateral quadrant of the right breast. Since she had all lymph nodes positive (28 in total), she had to have irradiated the supraclavicular region, as well as the breast with the tumor bed. She previously received chemotherapy, approved by the cardiologist. The patient was estimated to be with the high risk as device was within the field of irradiation, and the patient had high dependence on her pacemaker. The radiation therapy plan was conducted as 3D conformal therapy. The delineated target was breast with supraclavicular region, where the pacemaker was actually placed, with the addition of a pacemaker as organ at risk, to estimate the dose to the device and its components as recommended, and the breast. The targets received both 50 Gy in 25 fractions (where 20% of a pacemaker received 50 Gy, and 60% of a device received 40 Gy). The electrode to the heart received between 1 Gy and 50 Gy. Verification of dose planned and delivered was performed. Results: Evaluation of the patient status according to the guidelines and especially evaluation of all associated risks to the patient during treatment was done. Patient was irradiated by prescribed dose and followed up for the whole year, with no symptoms of failure of the pacemaker device during, or after treatment in follow up period. The functionality of a device was estimated to be unchanged, according to the parameters (electrode impedance and battery energy). Conclusion: Patient was closely monitored according to published guidelines during irradiation and afterwards. Pacemaker irradiated with the full dose did not show any signs of failure despite recommendations data, but in correlation with other published data.

Keywords: cardiac pacemaker, breast cancer, radiotherapy treatment planning, complications of treatment

Procedia PDF Downloads 438
25922 Comparative Evaluation of Pharmacologically Guided Approaches (PGA) to Determine Maximum Recommended Starting Dose (MRSD) of Monoclonal Antibodies for First Clinical Trial

Authors: Ibraheem Husain, Abul Kalam Najmi, Karishma Chester

Abstract:

First-in-human (FIH) studies are a critical step in clinical development of any molecule that has shown therapeutic promise in preclinical evaluations, since preclinical research and safety studies into clinical development is a crucial step for successful development of monoclonal antibodies for guidance in pharmaceutical industry for the treatment of human diseases. Therefore, comparison between USFDA and nine pharmacologically guided approaches (PGA) (simple allometry, maximum life span potential, brain weight, rule of exponent (ROE), two species methods and one species methods) were made to determine maximum recommended starting dose (MRSD) for first in human clinical trials using four drugs namely Denosumab, Bevacizumab, Anakinra and Omalizumab. In our study, the predicted pharmacokinetic (pk) parameters and the estimated first-in-human dose of antibodies were compared with the observed human values. The study indicated that the clearance and volume of distribution of antibodies can be predicted with reasonable accuracy in human and a good estimate of first human dose can be obtained from the predicted human clearance and volume of distribution. A pictorial method evaluation chart was also developed based on fold errors for simultaneous evaluation of various methods.

Keywords: clinical pharmacology (CPH), clinical research (CRE), clinical trials (CTR), maximum recommended starting dose (MRSD), clearance and volume of distribution

Procedia PDF Downloads 374
25921 Accuracy of Computed Tomography Dose Monitor Values: A Multicentric Study in India

Authors: Adhimoolam Saravana Kumar, K. N. Govindarajan, B. Devanand, R. Rajakumar

Abstract:

The quality of Computed Tomography (CT) procedures has improved in recent years due to technological developments and increased diagnostic ability of CT scanners. Due to the fact that CT doses are the peak among diagnostic radiology practices, it is of great significance to be aware of patient’s CT radiation dose whenever a CT examination is preferred. CT radiation dose delivered to patients in the form of volume CT dose index (CTDIvol) values, is displayed on scanner monitors at the end of each examination and it is an important fact to assure that this information is accurate. The objective of this study was to estimate the CTDIvol values for great number of patients during the most frequent CT examinations, to study the comparison between CT dose monitor values and measured ones, as well as to highlight the fluctuation of CTDIvol values for the same CT examination at different centres and scanner models. The output CT dose indices measurements were carried out on single and multislice scanners for available kV, 5 mm slice thickness, 100 mA and FOV combination used. The 100 CT scanners were involved in this study. Data with regard to 15,000 examinations in patients, who underwent routine head, chest and abdomen CT were collected using a questionnaire sent to a large number of hospitals. Out of the 15,000 examinations, 5000 were head CT examinations, 5000 were chest CT examinations and 5000 were abdominal CT examinations. Comprehensive quality assurance (QA) was performed for all the machines involved in this work. Followed by QA, CT phantom dose measurements were carried out in South India using actual scanning parameters used clinically by the hospitals. From this study, we have measured the mean divergence between the measured and displayed CTDIvol values were 5.2, 8.4, and -5.7 for selected head, chest and abdomen procedures for protocols as mentioned above, respectively. Thus, this investigation revealed an observable change in CT practices, with a much wider range of studies being performed currently in South India. This reflects the improved capacity of CT scanners to scan longer scan lengths and at finer resolutions as permitted by helical and multislice technology. Also, some of the CT scanners have used smaller slice thickness for routine CT procedures to achieve better resolution and image quality. It leads to an increase in the patient radiation dose as well as the measured CTDIv, so it is suggested that such CT scanners should select appropriate slice thickness and scanning parameters in order to reduce the patient dose. If these routine scan parameters for head, chest and abdomen procedures are optimized than the dose indices would be optimal and lead to the lowering of the CT doses. In South Indian region all the CT machines were routinely tested for QA once in a year as per AERB requirements.

Keywords: CT dose index, weighted CTDI, volumetric CTDI, radiation dose

Procedia PDF Downloads 257
25920 Impact of a Biopesticide Formulated an Entomopathogenic Fungus Metarhizium Anisopliae et Abstracts of Two Different Plants Sage (Salvia officinalis) and American Paper (Schinus molle) on Aphis Fabae (Homoptera - Aphididae)

Authors: Hicham Abidallah

Abstract:

In this work we realized a formulation of an entomopathogenic fungus Metarhizium anisopliae with a dose of 1,7 x 105 spores/ml, and aqueous abstracts of two different plants sage (Salvia officinalis) and American paper (Schinus molle) with they’re full dose and half dose, on a black bean aphid populations (Aphis fabae) on a bean crop planted in pots at semi-controlled conditions. Five formulations were achieved (Met, Fd, F1/2d, Sd et S1/2d) and tested on six blocks each one contained six pots. This study revealed that four (04) formulations exercised an influence over black bean aphid (Met, Fd, F1/2d, Sd), of which Metarhizium marked the most elevated and aggressive toxicity with an efficiency of 99,24%, however, sage formulation with the half dose (S1/2d ) marked a weak toxicity with an efficiency of 18%. Test of Metarhizium anisopliae on bees didn’t show toxicity, and no mortality has been marked, and no trace of green Muscardine observed.

Keywords: Metarhizium anisopliae, salvia officinalis, Schinus molle, Aphis fabae, efficiency degree

Procedia PDF Downloads 372
25919 Efficacy of Gamma Radiation on the Productivity of Bactrocera oleae Gmelin (Diptera: Tephritidae)

Authors: Mehrdad Ahmadi, Mohamad Babaie, Shiva Osouli, Bahareh Salehi, Nadia Kalantaraian

Abstract:

The olive fruit fly, Bactrocera oleae Gmelin (Diptera: Tephritidae), is one of the most serious pests in olive orchards in growing province in Iran. The female lay eggs in green olive fruit and larvae hatch inside the fruit, where they feed upon the fruit matters. One of the main ecologically friendly and species-specific systems of pest control is the sterile insect technique (SIT) which is based on the release of large numbers of sterilized insects. The objective of our work was to develop a SIT against B. oleae by using of gamma radiation for the laboratory and field trial in Iran. Oviposition of female mated by irradiated males is one of the main parameters to determine achievement of SIT. To conclude the sterile dose, pupae were placed under 0 to 160 Gy of gamma radiation. The main factor in SIT is the productivity of females which are mated by irradiated males. The emerged adults from irradiated pupae were mated with untreated adults of the same age by confining them inside the transparent cages. The fecundity of the irradiated males mated with non-irradiated females was decreased with the increasing radiation dose level. It was observed that the number of eggs and also the percentage of the egg hatching was significantly (P < 0.05) affected in either IM x NF crosses compared with NM x NF crosses in F1 generation at all doses. Also, the statistical analysis showed a significant difference (P < 0.05) in the mean number of eggs laid between irradiated and non-irradiated females crossed with irradiated males, which suggests that the males were susceptible to gamma radiation. The egg hatching percentage declined markedly with the increase of the radiation dose of the treated males in mating trials which demonstrated that egg hatch rate was dose dependent. Our results specified that gamma radiation affects the longevity of irradiated B. oleae larvae (established from irradiated pupae) and significantly increased their larval duration. Results show the gamma radiation, and SIT can be used successfully against olive fruit flies.

Keywords: fertility, olive fruit fly, radiation, sterile insect technique

Procedia PDF Downloads 196
25918 Open Fields' Dosimetric Verification for a Commercially-Used 3D Treatment Planning System

Authors: Nashaat A. Deiab, Aida Radwan, Mohamed Elnagdy, Mohamed S. Yahiya, Rasha Moustafa

Abstract:

This study is to evaluate and investigate the dosimetric performance of our institution's 3D treatment planning system, Elekta PrecisePLAN, for open 6MV fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields guided by the recommended QA tests prescribed in AAPM TG53, NCS report 15 test packages, IAEA TRS 430 and ESTRO booklet no.7. The study was performed for Elekta Precise linear accelerator designed for clinical range of 4, 6 and 15 MV photon beams with asymmetric jaws and fully integrated multileaf collimator that enables high conformance to target with sharp field edges. Seven different tests were done applied on solid water equivalent phantom along with 2D array dose detection system, the calculated doses using 3D treatment planning system PrecisePLAN, compared with measured doses to make sure that the dose calculations are accurate for open fields including square, rectangular, variation in SSD, centrally blocked, missing tissue, square MLC and MLC shaped fields. The QA results showed dosimetric accuracy of the TPS for open fields within the specified tolerance limits. However large square (25cm x 25cm) and rectangular fields (20cm x 5cm) some points were out of tolerance in penumbra region (11.38 % and 10.9 %, respectively). For the test of SSD variation, the large field resulted from SSD 125 cm for 10cm x 10cm filed the results recorded an error of 0.2% at the central axis and 1.01% in penumbra. The results yielded differences within the accepted tolerance level as recommended. Large fields showed variations in penumbra. These differences between dose values predicted by the TPS and the measured values at the same point may result from limitations of the dose calculation, uncertainties in the measurement procedure, or fluctuations in the output of the accelerator.

Keywords: quality assurance, dose calculation, 3D treatment planning system, photon beam

Procedia PDF Downloads 517
25917 Empirical Research on Rate of Return, Interest Rate and Mudarabah Deposit

Authors: Inten Meutia, Emylia Yuniarti

Abstract:

The objective of this study is to analyze the effects of interest rate, the rate of return of Islamic banks on the amount of mudarabah deposits in Islamic banks. In analyzing the effect of rate of return in the Islamic banks and interest rate risk in the conventional banks, the 1-month Islamic deposit rate of return and 1 month fixed deposit interest rate of a total Islamic deposit are considered. Using data covering the period from January 2010 to Sepember 2013, the study applies the regression analysis to analyze the effect between variable and independence t-test to analyze the mean difference between rate of return and rate of interest. Regression analysis shows that rate of return have significantly negative influence on mudarabah deposits, while interest rate have negative influence but not significant. The result of independent t test shows that the interest rate is not different from the rate of return in Islamic Bank. It supports the hyphotesis that rate of return in Islamic banking mimic rate of interest in conventional bank. The results of the study have important implications on the risk management practices of the Islamic banks in Indonesia.

Keywords: conventional bank, interest rate, Islamic bank, rate of return

Procedia PDF Downloads 512
25916 Cytotoxic Activity against Hepatocarcinoma and Cholangiocarcinoma Cells of Four Cathartic Herbal Medicines

Authors: Pranporn Kuropakornpong, Srisopa Ruangnoo, Arunporn Itharat

Abstract:

Liver cancer has the highest prevalence rate in the North and Northeast of Thailand. Four Thai medicinal plants such as resin of Ferula asafoetida Regel, latex of Aloe barbadensis Miller leaves, roots of Baliospermum manotanum, and latex of Garcinia hanburyi Hook are used in Thai traditional medicine as cathartic drug and detoxification in liver cancer patients. Thus, this research aimed to evaluate the cytotoxic activity of these plants against hepatocarcinoma (HepG2) and cholangiocarcinoma (KKU-M156) cells by SRB assay. These plants were macerated in 95% ethanol. The results showed that roots of Baliospermum manotanum and latex of Garcinia hanburyi Hook showed the strongest cytotoxicity against HepG2 (IC50 = 3.03+0.91 and 0.62+0.01µg/ml, respectively) and KKU-M156 (IC50 = 0.978+0.663 and 0.006+0.005 µg/ml, respectively). Latex of Garcinia hanburyi Hook also showed high cytotoxicity against normal cell line (IC50=8.86+0.31 µg/ml), and even though its selective values are high, dose of this herb should be limited.

Keywords: cholangiocarcinoma, cytotoxic activity, Garcinia hanburyi Hook, hepatocarcinoma

Procedia PDF Downloads 451
25915 The Use of Brachytherapy in the Treatment of Liver Metastases: A Systematic Review

Authors: Mateusz Bilski, Jakub Klas, Emilia Kowalczyk, Sylwia Koziej, Katarzyna Kulszo, Ludmiła Grzybowska- Szatkowska

Abstract:

Background: Liver metastases are a common complication of primary solid tumors and sig-nificantly reduce patient survival. In the era of increasing diagnosis of oligometastatic disease and oligoprogression, methods of local treatment of metastases, i.e. MDT, are becoming more important. Implementation of such treatment can be considered for liver metastases, which are a common complication of primary solid tumors and significantly reduce patient survival. To date, the mainstay of treatment for oligometastatic disease has been surgical resection, but not all patients qualify for the procedure. As an alternative to surgical resection, radiotherapy techniques have become available, including stereotactic body radiation therapy (SBRT) or high-dose interstitial brachytherapy (iBT). iBT is an invasive method that emits very high doses of radiation from the inside of the tumor to the outside. This technique provides better tumor coverage than SBRT while having little impact on surrounding healthy tissue and elim-inates some concerns involving respiratory motion. Methods: We conducted a systematic re-view of the scientific literature on the use of brachytherapy in the treatment of liver metasta-ses from 2018 - 2023 using PubMed and ResearchGate browsers according to PRISMA rules. Results: From 111 articles, 18 publications containing information on 729 patients with liver metastases were selected. iBT has been shown to provide high rates of tumor control. Among 14 patients with 54 unresectable RCC liver metastases, after iBT LTC was 92.6% during a median follow-up of 10.2 months, PFS was 3.4 months. In analysis of 167 patients after treatment with a single fractional dose of 15-25 Gy with brachytherapy at 6- and 12-month follow-up, LRFS rates of 88,4-88.7% and 70.7 - 71,5%, PFS of 78.1 and 53.8%, and OS of 92.3 - 96.7% and 76,3% - 79.6%, respectively, were achieved. No serious complications were observed in all patients. Distant intrahepatic progression occurred later in patients with unre-sectable liver metastases after brachytherapy (PFS: 19.80 months) than in HCC patients (PFS: 13.50 months). A significant difference in LRFS between CRC patients (84.1% vs. 50.6%) and other histologies (92.4% vs. 92.4%) was noted, suggesting a higher treatment dose is necessary for CRC patients. The average target dose for metastatic colorectal cancer was 40 - 60 Gy (compared to 100 - 250 Gy for HCC). To better assess sensitivity to therapy and pre-dict side effects, it has been suggested that humoral mediators be evaluated. It was also shown that baseline levels of TNF-α, MCP-1 and VEGF, as well as NGF and CX3CL corre-lated with both tumor volume and radiation-induced liver damage, one of the most serious complications of iBT, indicating their potential role as biomarkers of therapy outcome. Con-clusions: The use of brachytherapy methods in the treatment of liver metastases of various cancers appears to be an interesting and relatively safe therapeutic method alternative to sur-gery. An important challenge remains the selection of an appropriate brachytherapy method and radiation dose for the corresponding initial tumor type from which the metastasis origi-nated.

Keywords: liver metastases, brachytherapy, CT-HDRBT, iBT

Procedia PDF Downloads 114
25914 An Criterion to Minimize FE Mesh-Dependency in Concrete Plate Subjected to Impact Loading

Authors: Kwak, Hyo-Gyung, Gang, Han Gul

Abstract:

In the context of an increasing need for reliability and safety in concrete structures under blast and impact loading condition, the behavior of concrete under high strain rate condition has been an important issue. Since concrete subjected to impact loading associated with high strain rate shows quite different material behavior from that in the static state, several material models are proposed and used to describe the high strain rate behavior under blast and impact loading. In the process of modelling, in advance, mesh dependency in the used finite element (FE) is the key problem because simulation results under high strain-rate condition are quite sensitive to applied FE mesh size. It means that the accuracy of simulation results may deeply be dependent on FE mesh size in simulations. This paper introduces an improved criterion which can minimize the mesh-dependency of simulation results on the basis of the fracture energy concept, and HJC (Holmquist Johnson Cook), CSC (Continuous Surface Cap) and K&C (Karagozian & Case) models are examined to trace their relative sensitivity to the used FE mesh size. To coincide with the purpose of the penetration test with a concrete plate under a projectile (bullet), the residual velocities of projectile after penetration are compared. The correlation studies between analytical results and the parametric studies associated with them show that the variation of residual velocity with the used FE mesh size is quite reduced by applying a unique failure strain value determined according to the proposed criterion.

Keywords: high strain rate concrete, penetration simulation, failure strain, mesh-dependency, fracture energy

Procedia PDF Downloads 520
25913 Status of Radiation Protection at Radiation Oncology, BPKM Cancer Hospital, Nepal

Authors: Surendra B. Chand, P. P. Chaurasia, M. P. Adhikari, R. N. Yadav

Abstract:

Objective: The objective of this work was to evaluate all the safety procedures toward the radiation protection for workers in the radiation oncology department. Materials and Methods: The annual thermoluminescent dosimeters (TLDs) reports for five years of the staffs were evaluated, radiation surveys were done in the control consoles, radiotherapy machines room and waiting areas of all machines using Aloka survey meter. Results: The five years TLD reports shows that the whole body dose of the individual staffs is found within the annual dose limit except the accidental exposures. Radiation exposures in the working areas are also safe limits. Conclusion: The radiation safety practices for radiation protection are satisfactory and the radiation workers of the departments are found working within the safe limit.

Keywords: radiation protection, safety, ICRP, dose limits, TLD, radiation devices

Procedia PDF Downloads 570
25912 Comparison of Titanium and Aluminum Functions as Spoilers for Dose Uniformity Achievement in Abutting Oblique Electron Fields: A Monte Carlo Simulation Study

Authors: Faranak Felfeliyan, Parvaneh Shokrani, Maryam Atarod

Abstract:

Introduction Using electron beam is widespread in radiotherapy. The main criteria in radiation therapy is to irradiate the tumor volume with maximum prescribed dose and minimum dose to vital organs around it. Using abutting fields is common in radiotherapy. The main problem in using abutting fields is dose inhomogeneity in the junction region. Electron beam divergence and lateral scattering may lead to hot and cold spots in the junction region. One solution for this problem is using of a spoiler to broaden the penumbra and uniform dose in the junction region. The goal of this research was to compare titanium and aluminum effects as a spoiler for dose uniformity achievement in the junction region of oblique electron fields with Monte Carlo simulation. Dose uniformity in the junction region depends on density, scattering power, thickness of the spoiler and the angle between two fields. Materials and Methods In this study, Monte Carlo model of Siemens Primus linear accelerator was simulated for a 5 MeV nominal energy electron beam using manufacture provided specifications. BEAMnrc and EGSnrc user code were used to simulate the treatment head in electron mode (simulation of beam model). The resulting phase space file was used as a source for dose calculations for 10×10 cm2 field size at SSD=100 cm in a 30×30×45 cm3 water phantom using DOSXYZnrc user code (dose calculations). An automatic MP3-M water phantom tank, MEPHYSTO mc2 software platform and a Semi-Flex Chamber-31010 with sensitive vol­ume of 0.125 cm3 (PTW, Freiburg, Germany) were used for dose distribution measurements. Moreover, the electron field size was 10×10 cm2 and SSD=100 cm. Validation of devel­oped beam model was done by comparing the measured and calculated depth and lateral dose distributions (verification of electron beam model). Simulation of spoilers (using SLAB compo­nent module) placed at the end of the electron applicator, was done using previously vali­dated phase space file for a 5 MeV nominal energy and 10×10 cm2 field size (simulation of spoiler). An in-house routine was developed in order to calculate the combined isodose curves re­sulting from the two simulated abutting fields (calculation of dose distribution in abutting electron fields). Results Verification of the developed 5.9 MeV elec­tron beam model was done by comparing the calculated and measured dose distributions. The maximum percentage difference between calculated and measured PDD was 1%, except for the build-up region in which the difference was 2%. The difference between calculated and measured profile was 2% at the edges of the field and less than 1% in other regions. The effect of PMMA, aluminum, titanium and chromium in dose uniformity achievement in abutting normal electron fields with equivalent thicknesses to 5mm PMMA was evaluated. Comparing R90 and uniformity index of different materials, aluminum was chosen as the optimum spoiler. Titanium has the maximum surface dose. Thus, aluminum and titanium had been chosen to use for dose uniformity achievement in oblique electron fields. Using the optimum beam spoiler, junction dose decreased from 160% to 110% for 15 degrees, from 180% to 120% for 30 degrees, from 160% to 120% for 45 degrees and from 180% to 100% for 60 degrees oblique abutting fields. Using Titanium spoiler, junction dose decreased from 160% to 120% for 15 degrees, 180% to 120% for 30 degrees, 160% to 120% for 45 degrees and 180% to 110% for 60 degrees. In addition, penumbra width for 15 degrees, without spoiler in the surface was 10 mm and was increased to 15.5 mm with titanium spoiler. For 30 degrees, from 9 mm to 15 mm, for 45 degrees from 4 mm to 6 mm and for 60 degrees, from 5 mm to 8 mm. Conclusion Using spoilers, penumbra width at the surface increased, size and depth of hot spots was decreased and dose homogeneity improved at the junc­tion of abutting electron fields. Dose at the junction region of abutting oblique fields was improved significantly by using spoiler. Maximum dose at the junction region for 15⁰, 30⁰, 45⁰ and 60⁰ was decreased about 40%, 60%, 40% and 70% respectively for Titanium and about 50%, 60%, 40% and 80% for Aluminum. Considering significantly decrease in maximum dose using titanium spoiler, unfortunately, dose distribution in the junction region was not decreased less than 110%.

Keywords: abutting fields, electron beam, radiation therapy, spoilers

Procedia PDF Downloads 176
25911 Potential Therapeutic Effect of Obestatin in Oral Mucositis

Authors: Agnieszka Stempniewicz, Piotr Ceranowicz, Wojciech Macyk, Jakub Cieszkowski, Beata Kuśnierz-Cabała, Katarzyna Gałązka, Zygmunt Warzecha

Abstract:

Objectives: There are numerous strategies for the prevention or treatment of oral mucositis. However, their effectiveness is limited and does not correspond to expectations. Recent studies have shown that obestatin exhibits a protective effect and accelerates the healing of gastrointestinal mucosa. The aim of the present study was to examine the influence of obestatin administration on oral ulcers in rats. Methods: lingual ulcers were induced by the use of acetic acid. Rats were treated twice a day intraperitoneally with saline or obestatin(4, 8, or 16 nmol/kg/dose) for five days. The study determined: lingual mucosa morphology, cell proliferation, mucosal blood flow, and mucosal pro-inflammatory interleukin-1β level(IL-1β). Results: In animals without induction of oral ulcers, treatment with obestatin was without any effect. Obestatin administration in rats with lingual ulcers increased the healing rate of these ulcers. Obestatin given at the dose of 8 or 16 nmol/kg/dose caused the strongest and similar therapeutic effect. This result was associated with a significant increase in blood flow and cell proliferation in gingival mucosa, as well as a significant decrease in IL-1β level. Conclusions: Obestatin accelerates the healing of lingual ulcers in rats. This therapeutic effect is well-correlated with an increase in blood flow and cell proliferation in oral mucosa, as well as a decrease in pro-inflammatory IL-1β levels. Obestatin is a potentially useful candidate for the prevention and treatment of oral mucositis. Acknowledgment: Agnieszka Stempniewicz acknowledges the support of InterDokMed project no. POWR.03.02.00- 00-I013/16.

Keywords: oral mucositis, ulcers, obestatin, lingual mucosa

Procedia PDF Downloads 73
25910 Annual Effective Dose Associated with Radon in Groundwater Samples from Mining Communities Within the Ife-Ilesha Schist Belt, Southwestern Nigeria.

Authors: Paulinah Oyindamola Fasanmi, Matthew Omoniyi Isinkaye

Abstract:

In this study, the activity concentration of ²²²Rn in groundwater samples collected from gold and kaolin mining communities within the Ife-Ilesha schist belt, southwestern Nigeria, with their corresponding annual effective doses have been determined using the Durridge RAD-7, radon-in-water detector. The mean concentration of ²²²Rn in all the groundwater samples was 13.83 Bql-¹. In borehole water, ²²²Rn had a mean value of 20.68 Bql-¹, while it had a mean value of 11.67 Bql-¹ in well water samples. The mean activity concentration of radon obtained from the gold mining communities ranged from 1.6 Bql-¹ from Igun town to 4.8 Bql-¹ from Ilesha town. A higher mean value of 41.8 Bql-¹ was, however, obtained from Ijero, which is the kaolin mining community. The mean annual effective dose due to ingestion and inhalation of radon from groundwater samples was obtained to be 35.35 μSvyr-¹ and 34.86 nSvyr-¹, respectively. The mean annual ingestion dose estimated for well water samples was 29.90 μSvyr-¹, while 52.85 μSvyr-¹ was obtained for borehole water samples. On the other hand, the mean annual inhalation dose for well water was 29.49 nSvyr-¹, while for borehole water, 52.13 nSvyr-¹ was obtained. The mean annual effective dose due to ingestion of radon in groundwater from the gold mining communities ranged from 4.10 μSvyr-¹ from Igun to 13.1 μSvyr-¹ from Ilesha, while a mean value of 106.7 μSvyr-¹ was obtained from Ijero kaolin mining community. For inhalation, the mean value varied from 4.0 nSvyr-¹ from Igun to 12.9 nSvyr-¹ from Ilesha, while 105.2 nSvyr-¹ was obtained from the kaolin mining community. The mean annual effective dose due to ingestion and inhalation is lower than the reference level of 100 μSvyr-¹ recommended by World Health Organization except for values obtained from Ijero kaolin mining community, which exceeded the reference levels. It has been concluded that as far as radon-related health risks are concerned, groundwater from gold mining communities is generally safe, while groundwater from kaolin mining communities needs mitigation and monitoring. It has been discovered that Kaolin mining impacts groundwater with ²²²Rn than gold mining. Also, the radon level in borehole water exceeds its level in well water.

Keywords: 222Rn, Groundwater, Radioactivity, Annual Effective Dose, Mining.

Procedia PDF Downloads 69
25909 Larvicidal Activity of Azadirachtin and Essential Oils from Thymus capitatus against Prays oleae Bern (Lepidoptera, Yponomeutidae)

Authors: Imen Blibech, Mohiedine Ksantini, Mohamed Bouaziz

Abstract:

Prays oleae is a major insect of olive in the Mediterranean Region. In an effort to find effective and affordable ways of controlling this pest, larvicidal activity of essential oils from Tunisian Thymus capitatus were analyzed in comparison to Azadirachtin, a biologically active compound insecticide. The essential oils were extracted by hydrodistillation, and their chemical composition was determined by gas liquid-chromatography coupled with mass spectroscopy. The main components of chemical components were oxygenated monoterpenes (60.24%). The most abundant oxygenated monoterpenes were carvacrol (54.11%). Monoterpenes hydrocarbons were much more abundant and dominated by the o-cymene (16.68%). Both active compounds of Azadirachtin and Thymus capitatus oil extracts exhibited significant larvicidal activity against P. oleae with LC50 values 81.30 ppm and 52.49 ppm respectively. Dose-response relationships were established with almost 100% mortality when using the highest dose 100 ppm of T. capitatus oil extracts and 80 ppm of Azadirachtin. At the lowest dose (10 ppm), T. capitatus oil extracts and Azadirachtin caused 60% and 76% larval mortality in 48 hours respectively. The larval mortality rate greatly decreased with increases of the dilution of both oil extract compounds. Larval development duration appeared to be prolonged to about 12 days for larvae feeding on control diet. The maximum antifeedant activity was shown by both T. capitatus oil extract and Azadirachtin at LC90 values (47.5 and 50.1 ppm respectively). Tunisian T. capitatus oil extract used at low concentrations could be considered as eco-friendly promising insecticide similar to Azadirachtin that has significant potential for the biological control of P. oleae.

Keywords: Thymus capitatus, chemical composition, azadirachtin, larvicidal effects, antifeedant activity, Prays oleae

Procedia PDF Downloads 199
25908 Patterns of Self-Medication with Over-the-Counter Pain Relievers (Acetaminophen, Ibuprofen, and Aspirin) among the Kuwaiti Population

Authors: Nabil Ahmed Kamal Badawy, Ali Falah Alhajraf, Mawaheb Falah Alsamdan

Abstract:

Objectives: To estimate the prevalence of self-medication with over-the-counter pain relievers (acetaminophen, ibuprofen, and aspirin) among Kuwaiti citizens above the age of 16 years old and describe their patterns of use, perceived awareness of, and concerns about the drugs’ potential side effects. Design: A descriptive cross-sectional questionnaire-based survey. Setting: Samples were selected from the six Kuwaiti governorates. Subjects: The data were collected over a four-month period in 2012, from 850 subjects who identified as Kuwaiti citizens. These subjects were recruited using stratified random sampling. Results: Overall, a 67% response rate was obtained. In total, 68% (573) of the respondents reported the use of over-the-counter pain relievers. Women, middle-aged or single individuals, and those who had completed higher education used these drugs more than any other subgroup (p<0.05). We found evidence of inappropriate use of these drugs, with 15% (88) of the consumers using them almost daily. Further, 19% (111) of the consumers exceeded the recommended dosage at least once. Not only were 81% of the consumers unaware of the potential side effects, but also more than 61% were not concerned about them. Women were more knowledgeable than men regarding the maximum dose (p=0.036, OR 1.49, CI 1.03–2.17). Consumers with higher levels of education did not show distinct knowledge regarding the maximum allowed dose of the drugs (p=0.252, OR 1.71, CI 0.68-4.25). Conclusion: The results showed a high prevalence of self-medication with over-the-counter pain relievers among Kuwaiti citizens. The subjects showed marked unawareness and a lack of concern regarding the potential complications resulting from the inappropriate use of these analgesics. This demonstrates the need for educational interventions directed toward both patients and health care workers.

Keywords: awareness of side effects, concern, patterns of use, prevalence

Procedia PDF Downloads 500
25907 Method for Targeting Small Volume in Rat Brainby Gamma Knife and Dosimetric Control: Towards a Standardization

Authors: J. Constanzo, B. Paquette, G. Charest, L. Masson-Côté, M. Guillot

Abstract:

Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The first step is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Eleven euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomographic (CT), to estimate positioning variations regarding to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates assessed from CT images, various regions of the brain were delimited and a treatment plan was generated. A dose of 37 Gy at 30% isodose which corresponds to 100 Gy in 100% of the target volume (X = 98.1; Y = 109.1; Z = 100.0) was set by Leksell Gamma Plan using sectors number 4, 5, 7, and 8 of the Gamma Knife unit with the 4-mm diameter collimators. Effects of positioning accuracy of the rat brain on the dose deposition were simulated by Gamma Plan and validated with dosimetric measurements. Our results showed that 90% of the target volume received 110 ± 4.7 Gy and the maximum of deposited dose was 124 ± 0.6 Gy, which corresponds to an excellent relative standard deviation of 0.5%. This dose deposition calculated with the Gamma Plan was validated with the dosimetric films resulting in a dose-profile agreement within 2%, both in X- and Z-axis,. Our results demonstrate the feasibility to standardize the irradiation procedure of a small volume in the rat brain using a Gamma Knife.

Keywords: brain irradiation, dosimetry, gamma knife, small-animal irradiation, stereotactic radiosurgery (SRS)

Procedia PDF Downloads 407
25906 Optimization of the Drinking Water Treatment Process

Authors: M. Farhaoui, M. Derraz

Abstract:

Problem statement: In the water treatment processes, the coagulation and flocculation processes produce sludge according to the level of the water turbidity. The aluminum sulfate is the most common coagulant used in water treatment plants of Morocco as well as many countries. It is difficult to manage the sludge produced by the treatment plant. However, it can be used in the process to improve the quality of the treated water and reduce the aluminum sulfate dose. Approach: In this study, the effectiveness of sludge was evaluated at different turbidity levels (low, medium, and high turbidity) and coagulant dosage to find optimal operational conditions. The influence of settling time was also studied. A set of jar test experiments was conducted to find the sludge and aluminum sulfate dosages in order to improve the produced water quality for different turbidity levels. Results: Results demonstrated that using sludge produced by the treatment plant can improve the quality of the produced water and reduce the aluminum sulfate using. The aluminum sulfate dosage can be reduced from 40 to 50% according to the turbidity level (10, 20 and 40 NTU). Conclusions/Recommendations: Results show that sludge can be used in order to reduce the aluminum sulfate dosage and improve the quality of treated water. The highest turbidity removal efficiency is observed within 6 mg/l of aluminum sulfate and 35 mg/l of sludge in low turbidity, 20 mg/l of aluminum sulfate and 50 mg/l of sludge in medium turbidity and 20 mg/l of aluminum sulfate and 60 mg/l of sludge in high turbidity. The turbidity removal efficiency is 97.56%, 98.96% and 99.47% respectively for low, medium and high turbidity levels.

Keywords: coagulation process, coagulant dose, sludge, turbidity removal

Procedia PDF Downloads 335
25905 The Nutritive Value of Fermented Sago Pith (Metroxylon sago Rottb) Enriched with Micro Nutrients for Poultry Feed

Authors: Wizna, Helmi Muis, Hafil Abbas

Abstract:

An experiment was conducted to improve the nutrient value of sago pith (Metroxylon sago Rottb) supplemented with Zn, Sulfur and urea through fermentation by using cellulolytic bacteria (Bacillus amyloliquefaciens) as inoculums. The experiment was determination of the optimum dose combination (dosage of Zn, S and urea) for sago pith fermentation based on nutrient quality and quantity of these fermented products. The study was conducted in experimental method, using the completely randomized design in factorial with 3 treatments consist of: factor A (Dose of urea: A1 = 2.0%, A2 = 3.0%), factor B (Dose of S: B1 = 0.2%, B2 = 0.4%) and factor C (Dose of Zn: C1 = 0.0025%, C2 = 0.005%). Results of study showed that optimum condition for fermentation process of sago pith with B. amyloliquefaciens caused a change of nutrient content was obtained at urea (3%), S (0,2%), and Zn (0,0025%). This fermentation process was able to increase amino acid average, reduce crude fiber content by 67% and increase crude protein by 433%, which made the nutritional value of the product based on dry matter was 18.22% crude protein, 12.42% crude fiber, 2525 Kcal/kg metabolic energy and 65.73% nitrogen retention.

Keywords: fermentation, sago pith, sulfur, Zn, urea, Bacillus amyloliquefaciens

Procedia PDF Downloads 511
25904 A Prospective Study of a Clinically Significant Anatomical Change in Head and Neck Intensity-Modulated Radiation Therapy Using Transit Electronic Portal Imaging Device Images

Authors: Wilai Masanga, Chirapha Tannanonta, Sangutid Thongsawad, Sasikarn Chamchod, Todsaporn Fuangrod

Abstract:

The major factors of radiotherapy for head and neck (HN) cancers include patient’s anatomical changes and tumour shrinkage. These changes can significantly affect the planned dose distribution that causes the treatment plan deterioration. A measured transit EPID images compared to a predicted EPID images using gamma analysis has been clinically implemented to verify the dose accuracy as part of adaptive radiotherapy protocol. However, a global gamma analysis dose not sensitive to some critical organ changes as the entire treatment field is compared. The objective of this feasibility study is to evaluate the dosimetric response to patient anatomical changes during the treatment course in HN IMRT (Head and Neck Intensity-Modulated Radiation Therapy) using a novel comparison method; organ-of-interest gamma analysis. This method provides more sensitive to specific organ change detection. Random replanned 5 HN IMRT patients with causes of tumour shrinkage and patient weight loss that critically affect to the parotid size changes were selected and evaluated its transit dosimetry. A comprehensive physics-based model was used to generate a series of predicted transit EPID images for each gantry angle from original computed tomography (CT) and replan CT datasets. The patient structures; including left and right parotid, spinal cord, and planning target volume (PTV56) were projected to EPID level. The agreement between the transit images generated from original CT and replanned CT was quantified using gamma analysis with 3%, 3mm criteria. Moreover, only gamma pass-rate is calculated within each projected structure. The gamma pass-rate in right parotid and PTV56 between predicted transit of original CT and replan CT were 42.8%( ± 17.2%) and 54.7%( ± 21.5%). The gamma pass-rate for other projected organs were greater than 80%. Additionally, the results of organ-of-interest gamma analysis were compared with 3-dimensional cone-beam computed tomography (3D-CBCT) and the rational of replan by radiation oncologists. It showed that using only registration of 3D-CBCT to original CT does not provide the dosimetric impact of anatomical changes. Using transit EPID images with organ-of-interest gamma analysis can provide additional information for treatment plan suitability assessment.

Keywords: re-plan, anatomical change, transit electronic portal imaging device, EPID, head, and neck

Procedia PDF Downloads 216
25903 Reduction of Patient’s Dose of I-131 Therapy by Used Local Diuretic Juice

Authors: Mosab kh. A. A. Bashir, E. Mohamed-Ahmed

Abstract:

The aim of the study is to compare the results of the external exposure and the range of the dose spread by the patients, hospitalized in two different groups of 3-5 d receiving radioiodine therapy because of thyroid cancer, and one of group were giving the local diuretic plant (barley) as local juice. The control group was 28 patients they were isolated as international precautions after taken I-131 capsule 100 mCi, and their external exposure was recorded day by day after first 24 hrs. and the distance for external measurement was 1 m at the abdominal level. The mean of external exposure values of patients at fourth day were 30.24±12.92 µSv h−1. The second group after taking I-131 capsule 100 mCi we were given barley juice (250 mL) after every meal three times on day and their external exposure was recorded day by day after first 24 hrs. The mean of external exposure values of patients of this group at third day was 26.92±9.89 (14-55) µSv h−1. It was observed that the external exposure from the second group clearly decreased to low levels which contributed to the decrease in patient dose and also to the decrease in the exposure from the patient to his/her family.

Keywords: local diuretic juice, therapy, radiation medicine, diuretic plant

Procedia PDF Downloads 314
25902 Morroniside Intervention Mechanism of Renal Lesions, a Combination Model of AGEs Exacerbation of STZ-Induced Diabetes Mellitus

Authors: Hui-Qin Xu, Xing Lv, Yu-Han Tao

Abstract:

The depth study aimed on the mechanism of morroniside in protecting diabetic nephropathy. The diabetic mice models with blood glucose above 15mmol/L were divided into model, aminoguanidine, metformin, captopril, morroniside low-dose, and morroniside high-dose groups. And normal group was set simultaneously. All groups were fed with high AGEs food except normal group. Each group was intragastric administration of the corresponding medicine except model and normal groups. After 12 weeks, all the indictors were measured. It showed that the morroniside could reduce blood glucose significantly, urinary protein, serum urea nitrogen, creatine, pathological changes, AGEs levels, renal cortex RAGE mRNA and RAGE protein expression levels; increase food consumption, water intake, urine volume, insulin secretion. As a conclusion, morroniside from cornus officinalis can protect renal in diabetic mice, its mechanism may be related to the proliferation of islet cells, rectify glycometabolism, reduce serum and kidney AGEs content, and descend renal RAGEmRNA and RAGE protein expression levels.

Keywords: cornus officinalis, diabetic nephropathy, morroniside, RAGE protein

Procedia PDF Downloads 450
25901 Evaluation of Naringenin Role in Inhibiton of Lung Tumor Progression in Mice

Authors: Vishnu Varthan Vaithiyalingamjagannathan, M. N. Sathishkumar, K. S. Lakhsmi, D. Satheeshkumar, Srividyaammayappanrajam

Abstract:

Background:Naringenin, aglycone flavonoid possess certain activities like anti-oxidant, anti-estrogenic, anti-diabetic, cardioprotective, anti-obesity,anti-inflammatory, hepatoprotective and also have anti-cancer characteristics like carcinogenic inactivation, cell cycle arrest, anti-proliferation, apoptosis, anti-angiogenesis and enhances anti-oxidant activity. Methodology:The inhibitory effect of Naringenin in lung tumor progression estimated with adenocarcinoma (A549) cell lines (in vitro) and C57BL/6 mice injected with 5 X 106A549 cell lines (in vivo) in a tri-dose manner (Naringenin 100mg/kg,150mg/kg, and 200mg/kg) compared with standard chemotherapy drug cisplatin (7mg/kg). Results:The results of the present study revealed a dose-dependent activity in Naringenin and combination with cisplatin at a higher dose which showed decreased tumor progression in mice. In vitro studies carried out for estimation of cell survival and Nitric Oxide (NO) level, shows dose dependent action of Naringenin with IC50 value of 42µg/ml. In vivo studies were carried out in C57BL/6 mice. Naringenin satisfied the condition of an anti-cancer molecule with its characteristics in fragmentation assay, Zymography assay, anti-oxidant, and myeloperoxidase studies, than cisplatin which failed in anti-oxidant and myeloperoxidase effect. Both in vitro and in vivo establishes dose dependent decrease in NO levels. But whereas, Naringenin showed adverse results in Matrix Metalloproteinase (MMP) enzymatic levels with increase in dose levels. Conclusion:From the present study, Naringenin could suppress the lung tumor progression when given individually and also in combinatorial with standard chemotherapy drug.

Keywords: naringenin, in vitro, cell line, anticancer

Procedia PDF Downloads 435
25900 Determination of the Cooling Rate Dependency of High Entropy Alloys Using a High-Temperature Drop-on-Demand Droplet Generator

Authors: Saeedeh Imani Moqadam, Ilya Bobrov, Jérémy Epp, Nils Ellendt, Lutz Mädler

Abstract:

High entropy alloys (HEAs), having adjustable properties and enhanced stability compared with intermetallic compounds, are solid solution alloys that contain more than five principal elements with almost equal atomic percentage. The concept of producing such alloys pave the way for developing advanced materials with unique properties. However, the synthesis of such alloys may require advanced processes with high cooling rates depending on which alloy elements are used. In this study, the micro spheres of different diameters of HEAs were generated via a drop-on-demand droplet generator and subsequently solidified during free-fall in an argon atmosphere. Such droplet generators can generate individual droplets with high reproducibility regarding droplet diameter, trajectory and cooling while avoiding any interparticle momentum or thermal coupling. Metallography as well as X-ray diffraction investigations for each diameter of the generated metallic droplets where then carried out to obtain information about the microstructural state. To calculate the cooling rate of the droplets, a droplet cooling model was developed and validated using model alloys such as CuSn%6 and AlCu%4.5 for which a correlation of secondary dendrite arm spacing (SDAS) and cooling rate is well-known. Droplets were generated from these alloys and their SDAS was determined using quantitative metallography. The cooling rate was then determined from the SDAS and used to validate the cooling rates obtained from the droplet cooling model. The application of that model on the HEA then leads to the cooling rate dependency and hence to the identification of process windows for the synthesis of these alloys. These process windows were then compared with cooling rates obtained in processes such as powder production, spray forming, selective laser melting and casting to predict if a synthesis is possible with these processes.

Keywords: cooling rate, drop-on-demand, high entropy alloys, microstructure, single droplet generation, X-ray Diffractometry

Procedia PDF Downloads 211
25899 Determination of Strain Rate Sensitivity (SRS) for Grain Size Variants on Nanocrystalline Materials Produced by ARB and ECAP

Authors: P. B. Sob, T. B. Tengen, A. A. Alugongo

Abstract:

Mechanical behavior of 6082T6 aluminum is investigated at different temperatures. The strain rate sensitivity is investigated at different temperatures on the grain size variants. The sensitivity of the measured grain size variants on 3-D grain is discussed. It is shown that the strain rate sensitivities are negative for the grain size variants during the deformation of nanostructured materials. It is also observed that the strain rate sensitivities vary in different ways with the equivalent radius, semi minor axis radius, semi major axis radius and major axis radius. From the obtained results, it is shown that the variation of strain rate sensitivity with temperature suggests that the strain rate sensitivity at the low and the high temperature ends of the 6082T6 aluminum range is different. The obtained results revealed transition at different temperature from negative strain rate sensitivity as temperature increased on the grain size variants.

Keywords: nanostructured materials, grain size variants, temperature, yield stress, strain rate sensitivity

Procedia PDF Downloads 287
25898 Hepatoprotective Assessment of L-Ascorbate 1-(2-Hydroxyethyl)-4,6-Dimethyl-1, 2-Dihydropyrimidine-2-on in Toxic Liver Damage Test

Authors: Vladimir Zobov, Nail Nazarov, Alexandra Vyshtakalyuk, Vyacheslav Semenov, Irina Galyametdinova, Vladimir Reznik

Abstract:

The aim of this study was to investigate hepatoprotective properties of the Xymedon derivative L-ascorbate 1- (2-hydroxyethyl)-4,6-dimethyl-1,2-dihydropyrimidine-2-one (XD), which exhibits high efficiency as actoprotector. The study was carried out on 68 male albino rats weighing 250-400 g using preventive exposure to the test preparation. Effectiveness of XD win comparison with effectiveness of Xymedon (original substance) after administration of the compounds in identical doses. Maximum dose was 20 mg/kg. The animals orally received Xymedon or its derivative in doses of 10 and 20 mg/kg over 4 days. In 1-1.5 h after drug administration, CCl4 in vegetable oil (1:1) in a dose of 2 ml/kg. Controls received CCl4 but without hepatoprotectors. Intact control group consisted of rats, not receiving CCl4 or other compounds. The next day after the last administration of CCl4 and compounds under study animals were dehematized under ether anesthesia, blood and liver samples were taken for biochemical and histological analysis. Xymedon and XD administered according to the preventice scheme, exerted hepatoprotective effects: Xymedon — in the dose of 20 mg/kg, XD — in doses of 10 and 20 mg/kg. The drugs under study had different effects on liver condition, affected by induction with CCl4. Xymedon had a more pronounced effect both on the ALT level, which can be elevated not only due to destructive changes in hepatocytes, but also as a cholestasis manifestation, and on the serum total protein level, which reflects protein synthesis in liver. XD had a more pronounced effect on AST level, which is one of the markers of hepatocyte damage. Lower effective dose of XD — 10 mg/kg, compared to Xymedon effective according to, and its pronounced effect on AST, the hepatocyte cytolysis marker, is indicative of its higher preventive effectiveness, compared to Xymedon. This work was performed with the financial support of Russian Science Foundation (grant No: 14-50-00014).

Keywords: hepatoprotectors, pyrimidine derivatives, toxic liver damage, xymedon

Procedia PDF Downloads 302
25897 Multifunctional Bismuth-Based Nanoparticles as Theranostic Agent for Imaging and Radiation Therapy

Authors: Azimeh Rajaee, Lingyun Zhao, Shi Wang, Yaqiang Liu

Abstract:

In recent years many studies have been focused on bismuth-based nanoparticles as radiosensitizer and contrast agent in radiation therapy and imaging due to the high atomic number (Z = 82), high photoelectric absorption, low cost, and low toxicity. This study aims to introduce a new multifunctional bismuth-based nanoparticle as a theranostic agent for radiotherapy, computed tomography (CT) and magnetic resonance imaging (MRI). We synthesized bismuth ferrite (BFO, BiFeO3) nanoparticles by sol-gel method and surface of the nanoparticles were modified by Polyethylene glycol (PEG). After proved biocompatibility of the nanoparticles, the ability of them as contract agent in Computed tomography (CT) and magnetic resonance imaging (MRI) was investigated. The relaxation time rate (R2) in MRI and Hounsfield unit (HU) in CT imaging were increased with the concentration of the nanoparticles. Moreover, the effect of nanoparticles on dose enhancement in low energy was investigated by clonogenic assay. According to clonogenic assay, sensitizer enhancement ratios (SERs) were obtained as 1.35 and 1.76 for nanoparticle concentrations of 0.05 mg/ml and 0.1 mg/ml, respectively. In conclusion, our experimental results demonstrate that the multifunctional nanoparticles have the ability to employ as multimodal imaging and therapy to enhance theranostic efficacy.

Keywords: molecular imaging, nanomedicine, radiotherapy, theranostics

Procedia PDF Downloads 317
25896 Fluoride Removal from Groundwater in the East Nile Area (Sudan) Using Locally Available Charcoal

Authors: Motwkel M. Alhaj, Bashir M. Elhassan

Abstract:

The East Nile area is located in Khartoum state. The main source of drinking water in the East Nile Area (Sudan) is groundwater. However, fluoride concentration in the water is more than the maximum allowable dose, which is 1.5 mg/l. This study aims to demonstrate and innovative, affordable, and efficient filter to remove fluoride from drinking water. Many researchers have found that aluminum oxide-coated adsorbent is the most affordable technology for fluoride removal. However, adsorption is pH-dependent, and the water pH in the East Nile area is relatively high (around 8), which is hindering the adsorption process. Locally available charcoal was crushed, sieved, and coated with aluminum oxide. Then, different coating configurations were tested in order to produce an adsorbent with a high pH point of zero charge pH PZC in order to overcome the effect of high pH of water. Moreover, different methods were used to characterize the adsorbent, including: Scanning Electron Microscope (SEM), Energy Dispersive X-Ray Spectroscopy (EDX), Brunauer - Emmett - Teller (BET) method, and pH point of zero charge pH PZC. The produced adsorbent has pH PZC of 8.5, which is essential in enhancing the fluoride adsorption process. A pilot household fluoride filter was also designed and installed in a house that has water with 4.34 mg/l F- and pH of 8.4. The filter was operated at a flow rate 250 cm³/min. The total cost of treating one cubic meter was about 0.63$, while the cost for the same water before adsorbent coating modification was 2.33$⁄cm³.

Keywords: water treatment, fluoride, adsorption, charcoal, Sudan

Procedia PDF Downloads 116
25895 Relationship between Food Inflation and Agriculture Lending Rate in Ghana: A Vector Autoregressive Approach

Authors: Raymond K. Dziwornu

Abstract:

Lending rate of agriculture loan has persistently been high and attributed to risk in the sector. This study examined how food inflation and agriculture lending rate react to each other in Ghana using vector autoregressive approach. Quarterly data from 2006 to 2018 was obtained from the Bank of Ghana quarterly bulletin and the Ghana Statistical Service reports. The study found that a positive standard deviation shock to food inflation causes lending rate of agriculture loan to react negatively in the short run, but positively and steadily in the long run. This suggests the need to direct appropriate policy measures to reduce food inflation and consequently, the cost of credit to the agricultural sector for its growth.

Keywords: food inflation, agriculture, lending rate, vector autoregressive, Ghana

Procedia PDF Downloads 149