Search results for: stereotactic radiosurgery (SRS)
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 18

Search results for: stereotactic radiosurgery (SRS)

18 Comparison of Stereotactic Craniotomy for Brain Metastasis, as Compared to Stereotactic Radiosurgery

Authors: Mostafa El Khashab

Abstract:

Our experience with 50 patients with metastatic tumors located in different locations of the brain by a stereotactic-guided craniotomy and total microsurgical resection. Patients ranged in age from 36 to 73 years. There were 28 women and 22 men. Thirty-four patients presented with hemiparesis and 6 with aphasia and the remaining presented with psychological manifestations and memory issues. Gross total resection was accomplished in all cases, with postoperative imaging confirmation of complete removal. Forty patients were subjected to whole brain irradiation. One patient developed a stroke postoperatively and another one had a flap infection. 4 patients developed different postoperative but unrelated morbidities, including pneumonia and DVT. No mortality was encountered. We believe that with the assistance of stereotactic localization, metastases in vital regions of the brain can be removed with very low neurologic morbidity and that, in comparison to other modalities, they fare better regarding their long-term outcome.

Keywords: stereotactic, craniotomy, radiosurgery, patient

Procedia PDF Downloads 50
17 Method for Targeting Small Volume in Rat Brainby Gamma Knife and Dosimetric Control: Towards a Standardization

Authors: J. Constanzo, B. Paquette, G. Charest, L. Masson-Côté, M. Guillot

Abstract:

Targeted and whole-brain irradiation in humans can result in significant side effects causing decreased patient quality of life. To adequately investigate structural and functional alterations after stereotactic radiosurgery, preclinical studies are needed. The first step is to establish a robust standardized method of targeted irradiation on small regions of the rat brain. Eleven euthanized male Fischer rats were imaged in a stereotactic bed, by computed tomographic (CT), to estimate positioning variations regarding to the bregma skull reference point. Using a rat brain atlas and the stereotactic bregma coordinates assessed from CT images, various regions of the brain were delimited and a treatment plan was generated. A dose of 37 Gy at 30% isodose which corresponds to 100 Gy in 100% of the target volume (X = 98.1; Y = 109.1; Z = 100.0) was set by Leksell Gamma Plan using sectors number 4, 5, 7, and 8 of the Gamma Knife unit with the 4-mm diameter collimators. Effects of positioning accuracy of the rat brain on the dose deposition were simulated by Gamma Plan and validated with dosimetric measurements. Our results showed that 90% of the target volume received 110 ± 4.7 Gy and the maximum of deposited dose was 124 ± 0.6 Gy, which corresponds to an excellent relative standard deviation of 0.5%. This dose deposition calculated with the Gamma Plan was validated with the dosimetric films resulting in a dose-profile agreement within 2%, both in X- and Z-axis,. Our results demonstrate the feasibility to standardize the irradiation procedure of a small volume in the rat brain using a Gamma Knife.

Keywords: brain irradiation, dosimetry, gamma knife, small-animal irradiation, stereotactic radiosurgery (SRS)

Procedia PDF Downloads 379
16 Development of Multi-Leaf Collimator-Based Isocenter Verification Tool Using Electrical Portal Imaging Device for Stereotactic Radiosurgery

Authors: Panatda Intanin, Sangutid Thongsawad, Chirapha Tannanonta, Todsaporn Fuangrod

Abstract:

Stereotactic radiosurgery (SRS) is a highly precision delivery technique that requires comprehensive quality assurance (QA) tests prior to treatment delivery. An isocenter of delivery beam plays a critical role that affect the treatment accuracy. The uncertainty of isocenter is traditionally accessed using circular cone equipment, Winston-Lutz (WL) phantom and film. This technique is considered time consuming and highly dependent on the observer. In this work, the development of multileaf collimator (MLC)-based isocenter verification tool using electronic portal imaging device (EPID) was proposed and evaluated. A mechanical isocenter alignment with ball bearing diameter 5 mm and circular cone diameter 10 mm fixed to gantry head defines the radiation field was set as the conventional WL test method. The conventional setup was to compare to the proposed setup; using MLC (10 x 10 mm) to define the radiation filed instead of cone. This represents more realistic delivery field than using circular cone equipment. The acquisition from electronic portal imaging device (EPID) and radiographic film were performed in both experiments. The gantry angles were set as following: 0°, 90°, 180° and 270°. A software tool was in-house developed using MATLAB/SIMULINK programming to determine the centroid of radiation field and shadow of WL phantom automatically. This presents higher accuracy than manual measurement. The deviation between centroid of both cone-based and MLC-based WL tests were quantified. To compare between film and EPID image, the deviation for all gantry angle was 0.26±0.19mm and 0.43±0.30 for cone-based and MLC-based WL tests. For the absolute deviation calculation on EPID images between cone and MLC-based WL test was 0.59±0.28 mm and the absolute deviation on film images was 0.14±0.13 mm. Therefore, the MLC-based isocenter verification using EPID present high sensitivity tool for SRS QA.

Keywords: isocenter verification, quality assurance, EPID, SRS

Procedia PDF Downloads 114
15 Diffusion MRI: Clinical Application in Radiotherapy Planning of Intracranial Pathology

Authors: Pomozova Kseniia, Gorlachev Gennadiy, Chernyaev Aleksandr, Golanov Andrey

Abstract:

In clinical practice, and especially in stereotactic radiosurgery planning, the significance of diffusion-weighted imaging (DWI) is growing. This makes the existence of software capable of quickly processing and reliably visualizing diffusion data, as well as equipped with tools for their analysis in terms of different tasks. We are developing the «MRDiffusionImaging» software on the standard C++ language. The subject part has been moved to separate class libraries and can be used on various platforms. The user interface is Windows WPF (Windows Presentation Foundation), which is a technology for managing Windows applications with access to all components of the .NET 5 or .NET Framework platform ecosystem. One of the important features is the use of a declarative markup language, XAML (eXtensible Application Markup Language), with which you can conveniently create, initialize and set properties of objects with hierarchical relationships. Graphics are generated using the DirectX environment. The MRDiffusionImaging software package has been implemented for processing diffusion magnetic resonance imaging (dMRI), which allows loading and viewing images sorted by series. An algorithm for "masking" dMRI series based on T2-weighted images was developed using a deformable surface model to exclude tissues that are not related to the area of interest from the analysis. An algorithm of distortion correction using deformable image registration based on autocorrelation of local structure has been developed. Maximum voxel dimension was 1,03 ± 0,12 mm. In an elementary brain's volume, the diffusion tensor is geometrically interpreted using an ellipsoid, which is an isosurface of the probability density of a molecule's diffusion. For the first time, non-parametric intensity distributions, neighborhood correlations, and inhomogeneities are combined in one segmentation of white matter (WM), grey matter (GM), and cerebrospinal fluid (CSF) algorithm. A tool for calculating the coefficient of average diffusion and fractional anisotropy has been created, on the basis of which it is possible to build quantitative maps for solving various clinical problems. Functionality has been created that allows clustering and segmenting images to individualize the clinical volume of radiation treatment and further assess the response (Median Dice Score = 0.963 ± 0,137). White matter tracts of the brain were visualized using two algorithms: deterministic (fiber assignment by continuous tracking) and probabilistic using the Hough transform. The proposed algorithms test candidate curves in the voxel, assigning to each one a score computed from the diffusion data, and then selects the curves with the highest scores as the potential anatomical connections. White matter fibers were visualized using a Hough transform tractography algorithm. In the context of functional radiosurgery, it is possible to reduce the irradiation volume of the internal capsule receiving 12 Gy from 0,402 cc to 0,254 cc. The «MRDiffusionImaging» will improve the efficiency and accuracy of diagnostics and stereotactic radiotherapy of intracranial pathology. We develop software with integrated, intuitive support for processing, analysis, and inclusion in the process of radiotherapy planning and evaluating its results.

Keywords: diffusion-weighted imaging, medical imaging, stereotactic radiosurgery, tractography

Procedia PDF Downloads 49
14 Dynamic Conformal Arc versus Intensity Modulated Radiotherapy for Image Guided Stereotactic Radiotherapy of Cranial Lesion

Authors: Chor Yi Ng, Christine Kong, Loretta Teo, Stephen Yau, FC Cheung, TL Poon, Francis Lee

Abstract:

Purpose: Dynamic conformal arc (DCA) and intensity modulated radiotherapy (IMRT) are two treatment techniques commonly used for stereotactic radiosurgery/radiotherapy of cranial lesions. IMRT plans usually give better dose conformity while DCA plans have better dose fall off. Rapid dose fall off is preferred for radiotherapy of cranial lesions, but dose conformity is also important. For certain lesions, DCA plans have good conformity, while for some lesions, the conformity is just unacceptable with DCA plans, and IMRT has to be used. The choice between the two may not be apparent until each plan is prepared and dose indices compared. We described a deviation index (DI) which is a measurement of the deviation of the target shape from a sphere, and test its functionality to choose between the two techniques. Method and Materials: From May 2015 to May 2017, our institute has performed stereotactic radiotherapy for 105 patients treating a total of 115 lesions (64 DCA plans and 51 IMRT plans). Patients were treated with the Varian Clinac iX with HDMLC. Brainlab Exactrac system was used for patient setup. Treatment planning was done with Brainlab iPlan RT Dose (Version 4.5.4). DCA plans were found to give better dose fall off in terms of R50% (R50% (DCA) = 4.75 Vs R50% (IMRT) = 5.242) while IMRT plans have better conformity in terms of treatment volume ratio (TVR) (TVR(DCA) = 1.273 Vs TVR(IMRT) = 1.222). Deviation Index (DI) is proposed to better facilitate the choice between the two techniques. DI is the ratio of the volume of a 1 mm shell of the PTV and the volume of a 1 mm shell of a sphere of identical volume. DI will be close to 1 for a near spherical PTV while a large DI will imply a more irregular PTV. To study the functionality of DI, 23 cases were chosen with PTV volume ranged from 1.149 cc to 29.83 cc, and DI ranged from 1.059 to 3.202. For each case, we did a nine field IMRT plan with one pass optimization and a five arc DCA plan. Then the TVR and R50% of each case were compared and correlated with the DI. Results: For the 23 cases, TVRs and R50% of the DCA and IMRT plans were examined. The conformity for IMRT plans are better than DCA plans, with majority of the TVR(DCA)/TVR(IMRT) ratios > 1, values ranging from 0.877 to1.538. While the dose fall off is better for DCA plans, with majority of the R50%(DCA)/ R50%(IMRT) ratios < 1. Their correlations with DI were also studied. A strong positive correlation was found between the ratio of TVRs and DI (correlation coefficient = 0.839), while the correlation between the ratio of R50%s and DI was insignificant (correlation coefficient = -0.190). Conclusion: The results suggest DI can be used as a guide for choosing the planning technique. For DI greater than a certain value, we can expect the conformity for DCA plans to become unacceptably great, and IMRT will be the technique of choice.

Keywords: cranial lesions, dynamic conformal arc, IMRT, image guided radiotherapy, stereotactic radiotherapy

Procedia PDF Downloads 208
13 Frame to Frameless: Stereotactic Operation Progress in Robot Time

Authors: Zengmin Tian, Bin Lv, Rui Hui, Yupeng Liu, Chuan Wang, Qing Liu, Hongyu Li, Yan Qi, Li Song

Abstract:

Objective Robot was used for replacement of the frame in recent years. The paper is to investigate the safety and effectiveness of frameless stereotactic surgery in the treatment of children with cerebral palsy. Methods Clinical data of 425 children with spastic cerebral palsy were retrospectively analyzed. The patients were treated with robot-assistant frameless stereotactic surgery of nuclear mass destruction. The motor function was evaluated by gross motor function measure-88 (GMFM-88) before the operation, 1 week and 3 months after the operation respectively. The statistical analysis was performed. Results The postoperative CT showed that the destruction area covered the predetermined target in all the patients. Minimal bleeding of puncture channel occurred in 2 patient, and mild fever in 3 cases. Otherwise, there was no severe surgical complication occurred. The GMFM-88 scores were 49.1±22.5 before the operation, 52.8±24.2 and 64.2±21.4 at the time of 1 week and 3 months after the operation, respectively. There was statistical difference between before and after the operation (P<0.01). After 3 months, the total effective rate was 98.1%, and the average improvement rate of motor function was 24.3% . Conclusion Replaced the traditional frame, the robot-assistant frameless stereotactic surgery is safe and reliable for children with spastic cerebral palsy, which has positive significance in improving patients’ motor function.

Keywords: cerebral palsy, robotics, stereotactic techniques, frameless operation

Procedia PDF Downloads 48
12 An Audit of Local Guidance Compliance For Stereotactic Core Biopsy For DCIS In The Breast Screening Programme

Authors: Aisling Eves, Andrew Pieri, Ross McLean, Nerys Forester

Abstract:

Background: The breast unit local guideline recommends that 12 cores should be used in a stereotactic-guided biopsy to diagnose DCIS. Twelve cores are regarded to provide good diagnostic value without removing more breast tissue than necessary. This study aimed to determine compliance with guidelines and investigated how the number of cores impacted upon the re-excision rate and size discrepancies. Methods: This single-centre retrospective cohort study of 72 consecutive breast screened patients with <15mm DCIS on radiological report underwent stereotactic-guided core biopsy and subsequent surgical excision. Clinical, radiological, and histological data were collected over 5 years, and ASCO guidelines for margin involvement of <2mm was used to guide the need for re-excision. Results: Forty-six (63.9%) patients had <12 cores taken, and 26 (36.1%) patients had ≥12 cores taken. Only six (8.3%) patients had 12 cores taken in their stereotactic biopsy. Incomplete surgical excision was seen in 17 patients overall (23.6%), and of these patients, twelve (70.6%) had fewer than 12 cores taken (p=0.55 for the difference between groups). Mammogram and biopsy underestimated the size of the DCIS in this subgroup by a median of 15mm (range: 6-135mm). Re-excision was required in 9 patients (12.5%), and five patients (6.9%) were found to have invasive ductal carcinoma on excision (80% had <12 cores, p=0.43). Discussion: There is poor compliance with the breast unit local guidelines and higher rates of re-excision in patients who did not have ≥12 cores taken. Taking ≥12 cores resulted in fewer missed invasive cancers lower incomplete excision and re-excision rates.

Keywords: stereotactic core biopsy, DCIS, breast screening, Re-excision rates, core biopsy

Procedia PDF Downloads 93
11 Progress Towards Optimizing and Standardizing Fiducial Placement Geometry in Prostate, Renal, and Pancreatic Cancer

Authors: Shiva Naidoo, Kristena Yossef, Grimm Jimm, Mirza Wasique, Eric Kemmerer, Joshua Obuch, Anand Mahadevan

Abstract:

Background: Fiducial markers effectively enhance tumor target visibility prior to Stereotactic Body Radiation Therapy or Proton therapy. To streamline clinical practice, fiducial placement guidelines from a robotic radiosurgery vendor were examined with the goals of optimizing and standardizing feasible geometries for each treatment indication. Clinical examples of prostate, renal, and pancreatic cases are presented. Methods: Vendor guidelines (Accuray, Sunnyvale, Ca) suggest implantation of 4–6 fiducials at least 20 mm apart, with at least a 15-degree angular difference between fiducials, within 50 mm or less from the target centroid, to ensure that any potential fiducial motion (e.g., from respiration or abdominal/pelvic pressures) will mimic target motion. Also recommended is that all fiducials can be seen in 45-degree oblique views with no overlap to coincide with the robotic radiosurgery imaging planes. For the prostate, a standardized geometry that meets all these objectives is a 2 cm-by-2 cm square in the coronal plane. The transperineal implant of two pairs of preloaded tandem fiducials makes the 2 cm-by-2 cm square geometry clinically feasible. This technique may be applied for renal cancer, except repositioned in a sagittal plane, with the retroperitoneal placement of the fiducials into the tumor. Pancreatic fiducial placement via endoscopic ultrasound (EUS) is technically more challenging, as fiducial placement is operator-dependent, and lesion access may be limited by adjacent vasculature, tumor location, or restricted mobility of the EUS probe in the duodenum. Fluoroscopically assisted fiducial placement during EUS can help ensure fiducial markers are deployed with optimal geometry and visualization. Results: Among the first 22 fiducial cases on a newly installed robotic radiosurgery system, live x-ray images for all nine prostatic cases had excellent fiducial visualization at the treatment console. Renal and pancreatic fiducials were not as clearly visible due to difficult target access and smaller caliber insertion needle/fiducial usage. The geometry of the first prostate case was used to ensure accurate geometric marker placement for the remaining 8 cases. Initially, some of the renal and pancreatic fiducials were closer than the 20 mm recommendation, and interactive feedback with the proceduralists led to subsequent fiducials being too far to the edge of the tumor. Further feedback and discussion of all cases are being used to help guide standardized geometries and achieve ideal fiducial placement. Conclusion: The ideal tradeoffs of fiducial visibility versus the thinnest possible gauge needle to avoid complications needs to be systematically optimized among all patients, particularly in regards to body habitus. Multidisciplinary collaboration among proceduralists and radiation oncologists can lead to improved outcomes.

Keywords: fiducial, prostate cancer, renal cancer, pancreatic cancer, radiotherapy

Procedia PDF Downloads 62
10 Diagnostic Efficacy and Usefulness of Digital Breast Tomosynthesis (DBT) in Evaluation of Breast Microcalcifications as a Pre-Procedural Study for Stereotactic Biopsy

Authors: Okhee Woo, Hye Seon Shin

Abstract:

Purpose: To investigate the diagnostic power of digital breast tomosynthesis (DBT) in evaluation of breast microcalcifications and usefulness as a pre-procedural study for stereotactic biopsy in comparison with full-field digital mammogram (FFDM) and FFDM plus magnification image (FFDM+MAG). Methods and Materials: An IRB approved retrospective observer performance study on DBT, FFDM, and FFDM+MAG was done. Image quality was rated in 5-point scoring system for lesion clarity (1, very indistinct; 2, indistinct; 3, fair; 4, clear; 5, very clear) and compared by Wilcoxon test. Diagnostic power was compared by diagnostic values and AUC with 95% confidence interval. Additionally, procedural report of biopsy was analysed for patient positioning and adequacy of instruments. Results: DBT showed higher lesion clarity (median 5, interquartile range 4-5) than FFDM (3, 2-4, p-value < 0.0001), and no statistically significant difference to FFDM+MAG (4, 4-5, p-value=0.3345). Diagnostic sensitivity and specificity of DBT were 86.4% and 92.5%; FFDM 70.4% and 66.7%; FFDM+MAG 93.8% and 89.6%. The AUCs of DBT (0.88) and FFDM+MAG (0.89) were larger than FFDM (0.59, p-values < 0.0001) but there was no statistically significant difference between DBT and FFDM+MAG (p-value=0.878). In 2 cases with DBT, petit needle could be appropriately prepared; and other 3 without DBT, patient repositioning was needed. Conclusion: DBT showed better image quality and diagnostic values than FFDM and equivalent to FFDM+MAG in the evaluation of breast microcalcifications. Evaluation with DBT as a pre-procedural study for breast stereotactic biopsy can lead to more accurate localization and successful biopsy and also waive the need for additional magnification images.

Keywords: DBT, breast cancer, stereotactic biopsy, mammography

Procedia PDF Downloads 269
9 Audit of TPS photon beam dataset for small field output factors using OSLDs against RPC standard dataset

Authors: Asad Yousuf

Abstract:

Purpose: The aim of the present study was to audit treatment planning system beam dataset for small field output factors against standard dataset produced by radiological physics center (RPC) from a multicenter study. Such data are crucial for validity of special techniques, i.e., IMRT or stereotactic radiosurgery. Materials/Method: In this study, multiple small field size output factor datasets were measured and calculated for 6 to 18 MV x-ray beams using the RPC recommend methods. These beam datasets were measured at 10 cm depth for 10 × 10 cm2 to 2 × 2 cm2 field sizes, defined by collimator jaws at 100 cm. The measurements were made with a Landauer’s nanoDot OSLDs whose volume is small enough to gather a full ionization reading even for the 1×1 cm2 field size. At our institute the beam data including output factors have been commissioned at 5 cm depth with an SAD setup. For comparison with the RPC data, the output factors were converted to an SSD setup using tissue phantom ratios. SSD setup also enables coverage of the ion chamber in 2×2 cm2 field size. The measured output factors were also compared with those calculated by Eclipse™ treatment planning software. Result: The measured and calculated output factors are in agreement with RPC dataset within 1% and 4% respectively. The large discrepancies in TPS reflect the increased challenge in converting measured data into a commissioned beam model for very small fields. Conclusion: OSLDs are simple, durable, and accurate tool to verify doses that delivered using small photon beam fields down to a 1x1 cm2 field sizes. The study emphasizes that the treatment planning system should always be evaluated for small field out factors for the accurate dose delivery in clinical setting.

Keywords: small field dosimetry, optically stimulated luminescence, audit treatment, radiological physics center

Procedia PDF Downloads 297
8 Wire Localization Procedures in Non-Palpable Breast Cancers: An Audit Report and Review of Literature

Authors: Waqas Ahmad, Eisha Tahir, Shahper Aqeel, Imran Khalid Niazi, Amjad Iqbal

Abstract:

Background: Breast conservation surgery applies a number of techniques for accurate localization of lesions. Wire localization remains the method of choice in non-palpable breast cancers post-neoadjuvant chemotherapy. Objective: The aim of our study was to determine the accuracy of wire localization procedures in our department and compare it with internationally set protocols as per the Royal College of Radiologists. Post wire mammography, as well as the margin status of the postoperative specimen, assessed the accuracy of the procedure. Methods: We retrospectively reviewed the data of 225 patients who presented to our department from May 2014 to June 2015 post neoadjuvant chemotherapy with non-palpable cancers. These patients are candidates for wire localized lumpectomies either under ultrasound or stereotactic guidance. Metallic marker was placed in all the patients at the time of biopsy. Post wire mammogram was performed in all the patients and the distance of the wire tip from the marker was calculated. The presence or absence of the metallic clip in the postoperative specimen, as well as the marginal status of the postoperative specimen, was noted. Results: 157 sonographic and 68 stereotactic wire localization procedures were performed. 95% of the wire tips were within 1 cm of the metallic marker. Marginal status was negative in 94% of the patients in histopathological specimen. Conclusion: Our audit report declares more than 95% accuracy of image guided wire localization in successful excision of non-palpable breast lesions.

Keywords: breast, cancer, non-palpable, wire localization

Procedia PDF Downloads 281
7 One Year Follow up of Head and Neck Paragangliomas: A Single Center Experience

Authors: Cecilia Moreira, Rita Paiva, Daniela Macedo, Leonor Ribeiro, Isabel Fernandes, Luis Costa

Abstract:

Background: Head and neck paragangliomas are a rare group of tumors with a large spectrum of clinical manifestations. The approach to evaluate and treat these lesions has evolved over the last years. Surgery was the standard for the approach of these patients, but nowadays new techniques of imaging and radiation therapy changed that paradigm. Despite advances in treating, the growth potential and clinical outcome of individual cases remain largely unpredictable. Objectives: Characterization of our institutional experience with clinical management of these tumors. Methods: This was a cross-sectional study of patients followed in our institution between 01 January and 31 December 2017 with paragangliomas of the head and neck and cranial base. Data on tumor location, catecholamine levels, and specific imaging modalities employed in diagnostic workup, treatment modality, tumor control and recurrence, complications of treatment and hereditary status were collected and summarized. Results: A total of four female patients were followed between 01 January and 31 December 2017 in our institution. The mean age of our cohort was 53 (± 16.1) years. The primary locations were at the level of the tympanic jug (n=2, 50%) and carotid body (n=2, 50%), and only one of the tumors of the carotid body presented pulmonary metastasis at the time of diagnosis. None of the lesions were catecholamine-secreting. Two patients underwent genetic testing, with no mutations identified. The initial clinical presentation was variable highlighting the decrease of visual acuity and headache as symptoms present in all patients. In one of the cases, loss of all teeth of the lower jaw was the presenting symptomatology. Observation with serial imaging, surgical extirpation, radiation, and stereotactic radiosurgery were employed as treatment approaches according to anatomical location and resectability of lesions. As post-therapeutic sequels the persistence of tinnitus and disabling pain stands out, presenting one of the patients neuralgia of the glossopharyngeal. Currently, all patients are under regular surveillance with a median follow up of 10 months. Conclusion: Ultimately, clinical management of these tumors remains challenging owing to heterogeneity in clinical presentation, the existence of multiple treatment alternatives, and potential to cause serious detriment to critical functions and consequently interference with the quality of life of the patients.

Keywords: clinical outcomes, head and neck, management, paragangliomas

Procedia PDF Downloads 116
6 The Invaluable Contributions of Radiography and Radiotherapy in Modern Medicine

Authors: Sahar Heidary

Abstract:

Radiography and radiotherapy have emerged as crucial pillars of modern medical practice, revolutionizing diagnostics and treatment for a myriad of health conditions. This abstract highlights the pivotal role of radiography and radiotherapy in favor of healthcare and society. Radiography, a non-invasive imaging technique, has significantly advanced medical diagnostics by enabling the visualization of internal structures and abnormalities within the human body. With the advent of digital radiography, clinicians can obtain high-resolution images promptly, leading to faster diagnoses and informed treatment decisions. Radiography plays a pivotal role in detecting fractures, tumors, infections, and various other conditions, allowing for timely interventions and improved patient outcomes. Moreover, its widespread accessibility and cost-effectiveness make it an indispensable tool in healthcare settings worldwide. On the other hand, radiotherapy, a branch of medical science that utilizes high-energy radiation, has become an integral component of cancer treatment and management. By precisely targeting and damaging cancerous cells, radiotherapy offers a potent strategy to control tumor growth and, in many cases, leads to cancer eradication. Additionally, radiotherapy is often used in combination with surgery and chemotherapy, providing a multifaceted approach to combat cancer comprehensively. The continuous advancements in radiotherapy techniques, such as intensity-modulated radiotherapy and stereotactic radiosurgery, have further improved treatment precision while minimizing damage to surrounding healthy tissues. Furthermore, radiography and radiotherapy have demonstrated their worth beyond oncology. Radiography is instrumental in guiding various medical procedures, including catheter placement, joint injections, and dental evaluations, reducing complications and enhancing procedural accuracy. On the other hand, radiotherapy finds applications in non-cancerous conditions like benign tumors, vascular malformations, and certain neurological disorders, offering therapeutic options for patients who may not benefit from traditional surgical interventions. In conclusion, radiography and radiotherapy stand as indispensable tools in modern medicine, driving transformative improvements in patient care and treatment outcomes. Their ability to diagnose, treat, and manage a wide array of medical conditions underscores their favor in medical practice. As technology continues to advance, radiography and radiotherapy will undoubtedly play an ever more significant role in shaping the future of healthcare, ultimately saving lives and enhancing the quality of life for countless individuals worldwide.

Keywords: radiology, radiotherapy, medical imaging, cancer treatment

Procedia PDF Downloads 36
5 Comparing ITV Definitions From 4D CT-PET and Breath-Hold Technique with Abdominal Compression

Authors: R. D. Esposito, P. Dorado Rodriguez, D. Planes Meseguer

Abstract:

In this work, we compare the contour of Internal Target Volume (ITV), for Stereotactic Body Radiation Therapy (SBRT) of a patient affected by a single liver metastasis, obtained from two different patient data acquisition techniques. The first technique consists in a free breathing Computer Tomography (CT) scan acquisition, followed by exhalation breath-hold and inhalation breath-hold CT scans, all of them applying abdominal compression while the second technique consists in a free breathing 4D CT-PET (Positron Emission Tomography) scan. Results obtained with these two methods are consistent, which demonstrate that at least for this specific case, both techniques are adequate for ITV contouring in SBRT treatments.

Keywords: 4D CT-PET, abdominal compression, ITV, SBRT

Procedia PDF Downloads 414
4 Obsessive-Compulsive Disorder: Development of Demand-Controlled Deep Brain Stimulation with Methods from Stochastic Phase Resetting

Authors: Mahdi Akhbardeh

Abstract:

Synchronization of neuronal firing is a hallmark of several neurological diseases. Recently, stimulation techniques have been developed which make it possible to desynchronize oscillatory neuronal activity in a mild and effective way, without suppressing the neurons' firing. As yet, these techniques are being used to establish demand-controlled deep brain stimulation (DBS) techniques for the therapy of movement disorders like severe Parkinson's disease or essential tremor. We here present a first conceptualization suggesting that the nucleus accumbens is a promising target for the standard, that is, permanent high-frequency, DBS in patients with severe and chronic obsessive-compulsive disorder (OCD). In addition, we explain how demand-controlled DBS techniques may be applied to the therapy of OCD in those cases that are refractory to behavioral therapies and pharmacological treatment.

Keywords: stereotactic neurosurgery, deep brain stimulation, obsessive-compulsive disorder, phase resetting

Procedia PDF Downloads 476
3 Comparison of Stereotactic Body Radiation Therapy Virtual Treatment Plans Obtained With Different Collimators in the Cyberknife System in Partial Breast Irradiation: A Retrospective Study

Authors: Öznur Saribaş, Si̇bel Kahraman Çeti̇ntaş

Abstract:

It is aimed to compare target volume and critical organ doses by using CyberKnife (CK) in accelerated partial breast irradiation (APBI) in patients with early stage breast cancer. Three different virtual plans were made for Iris, fixed and multi-leaf collimator (MLC) for 5 patients who received radiotherapy in the CyberKnife system. CyberKnife virtual plans were created, with 6 Gy per day totaling 30 Gy. Dosimetric parameters for the three collimators were analyzed according to the restrictions in the NSABP-39/RTOG 0413 protocol. The plans ensured critical organs were protected and GTV received 95 % of the prescribed dose. The prescribed dose was defined by the isodose curve of a minimum of 80. Homogeneity index (HI), conformity index (CI), treatment time (min), monitor unit (MU) and doses taken by critical organs were compared. As a result of the comparison of the plans, a significant difference was found for the duration of treatment, MU. However, no significant difference was found for HI, CI. V30 and V15 values of the ipsi-lateral breast were found in the lowest MLC. There was no significant difference between Dmax values for lung and heart. However, the mean MU and duration of treatment were found in the lowest MLC. As a result, the target volume received the desired dose in each collimator. The contralateral breast and contralateral lung doses were the lowest in the Iris. Fixed collimator was found to be more suitable for cardiac doses. But these values did not make a significant difference. The use of fixed collimators may cause difficulties in clinical applications due to the long treatment time. The choice of collimator in breast SBRT applications with CyberKnife may vary depending on tumor size, proximity to critical organs and tumor localization.

Keywords: APBI, CyberKnife, early stage breast cancer, radiotherapy.

Procedia PDF Downloads 96
2 The Use of Brachytherapy in the Treatment of Liver Metastases: A Systematic Review

Authors: Mateusz Bilski, Jakub Klas, Emilia Kowalczyk, Sylwia Koziej, Katarzyna Kulszo, Ludmiła Grzybowska- Szatkowska

Abstract:

Background: Liver metastases are a common complication of primary solid tumors and sig-nificantly reduce patient survival. In the era of increasing diagnosis of oligometastatic disease and oligoprogression, methods of local treatment of metastases, i.e. MDT, are becoming more important. Implementation of such treatment can be considered for liver metastases, which are a common complication of primary solid tumors and significantly reduce patient survival. To date, the mainstay of treatment for oligometastatic disease has been surgical resection, but not all patients qualify for the procedure. As an alternative to surgical resection, radiotherapy techniques have become available, including stereotactic body radiation therapy (SBRT) or high-dose interstitial brachytherapy (iBT). iBT is an invasive method that emits very high doses of radiation from the inside of the tumor to the outside. This technique provides better tumor coverage than SBRT while having little impact on surrounding healthy tissue and elim-inates some concerns involving respiratory motion. Methods: We conducted a systematic re-view of the scientific literature on the use of brachytherapy in the treatment of liver metasta-ses from 2018 - 2023 using PubMed and ResearchGate browsers according to PRISMA rules. Results: From 111 articles, 18 publications containing information on 729 patients with liver metastases were selected. iBT has been shown to provide high rates of tumor control. Among 14 patients with 54 unresectable RCC liver metastases, after iBT LTC was 92.6% during a median follow-up of 10.2 months, PFS was 3.4 months. In analysis of 167 patients after treatment with a single fractional dose of 15-25 Gy with brachytherapy at 6- and 12-month follow-up, LRFS rates of 88,4-88.7% and 70.7 - 71,5%, PFS of 78.1 and 53.8%, and OS of 92.3 - 96.7% and 76,3% - 79.6%, respectively, were achieved. No serious complications were observed in all patients. Distant intrahepatic progression occurred later in patients with unre-sectable liver metastases after brachytherapy (PFS: 19.80 months) than in HCC patients (PFS: 13.50 months). A significant difference in LRFS between CRC patients (84.1% vs. 50.6%) and other histologies (92.4% vs. 92.4%) was noted, suggesting a higher treatment dose is necessary for CRC patients. The average target dose for metastatic colorectal cancer was 40 - 60 Gy (compared to 100 - 250 Gy for HCC). To better assess sensitivity to therapy and pre-dict side effects, it has been suggested that humoral mediators be evaluated. It was also shown that baseline levels of TNF-α, MCP-1 and VEGF, as well as NGF and CX3CL corre-lated with both tumor volume and radiation-induced liver damage, one of the most serious complications of iBT, indicating their potential role as biomarkers of therapy outcome. Con-clusions: The use of brachytherapy methods in the treatment of liver metastases of various cancers appears to be an interesting and relatively safe therapeutic method alternative to sur-gery. An important challenge remains the selection of an appropriate brachytherapy method and radiation dose for the corresponding initial tumor type from which the metastasis origi-nated.

Keywords: liver metastases, brachytherapy, CT-HDRBT, iBT

Procedia PDF Downloads 79
1 Multi-Institutional Report on Toxicities of Concurrent Nivolumab and Radiation Therapy

Authors: Neha P. Amin, Maliha Zainib, Sean Parker, Malcolm Mattes

Abstract:

Purpose/Objectives: Combination immunotherapy (IT) and radiation therapy (RT) is an actively growing field of clinical investigation due to promising findings of synergistic effects from immune-mediated mechanisms observed in preclinical studies and clinical data from case reports of abscopal effects. While there are many ongoing trials of combined IT-RT, there are still limited data on toxicity and outcome optimization regarding RT dose, fractionation, and sequencing of RT with IT. Nivolumab (NIVO), an anti-PD-1 monoclonal antibody, has been rapidly adopted in the clinic over the past 2 years, resulting in more patients being considered for concurrent RT-NIVO. Knowledge about the toxicity profile of combined RT-NIVO is important for both the patient and physician when making educated treatment decisions. The acute toxicity profile of concurrent RT-NIVO was analyzed in this study. Materials/Methods: A retrospective review of all consecutive patients who received NIVO from 1/2015 to 5/2017 at 4 separate centers within two separate institutions was performed. Those patients who completed a course of RT from 1 day prior to initial NIVO infusion through 1 month after last NIVO infusion were considered to have received concurrent therapy and included in the subsequent analysis. Descriptive statistics are reported for patient/tumor/treatment characteristics and observed acute toxicities within 3 months of RT completion. Results: Among 261 patients who received NIVO, 46 (17.6%) received concurrent RT to 67 different sites. The median f/u was 3.3 (.1-19.8) months, and 11/46 (24%) were still alive at last analysis. The most common histology, RT prescription, and treatment site included non-small cell lung cancer (23/46, 50%), 30 Gy in 10 fractions (16/67, 24%), and central thorax/abdomen (26/67, 39%), respectively. 79% (53/67) of irradiated sites were treated with 3D-conformal technique and palliative dose-fractionation. Grade 3, 4, and 5 toxicities were experienced by 11, 1, and 2 patients, respectively. However all grade 4 and 5 toxicities were outside of the irradiated area and attributed to the NIVO alone, and only 4/11 (36%) of the grade 3 toxicities were attributed to the RT-NIVO. The irradiated site in these cases included the brain [2/10 (20%)] and central thorax/abdomen [2/19 (10.5%)], including one unexpected grade 3 pancreatitides following stereotactic body RT to the left adrenal gland. Conclusions: Concurrent RT-NIVO is generally well tolerated, though with potentially increased rates of severe toxicity when irradiating the lung, abdomen, or brain. Pending more definitive data, we recommend counseling patients on the potentially increased rates of side effects from combined immunotherapy and radiotherapy to these locations. Future prospective trials assessing fractionation and sequencing of RT with IT will help inform combined therapy recommendations.

Keywords: combined immunotherapy and radiation, immunotherapy, Nivolumab, toxicity of concurrent immunotherapy and radiation

Procedia PDF Downloads 362