Search results for: Mitral valve surgery
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1250

Search results for: Mitral valve surgery

500 Anterior Chamber Depth Measured with Orbscan and Pentacam Compared with Smith Method in 102 Phakic Eyes

Authors: Mohammad Ghandehari Motlagh

Abstract:

Purpose: Comparing anterior chamber depth (ACD) measured with Orbscan II and Pentacam HR compared with the Smith method results. Methods: Smith method (1979) is a reliable method of measuring ACD only with help of slit lamp. In this study 102 phakic eyes as PRK candidates were imaged with both OrbScan and Pentacam and finally ACD was measured thru Smith method with slit lamp. ACD measured with Smith method was presumed as the gold standard and was compared with ACD of the 2 imaging devices. Contraindication cases for PRK and pseudophakic eyes have been excluded from the study. Results: Mean age of the patients was 35.2 ±14.8 yrs/old including 56 M(54.9%)and 46 F(45.09%).Acceptable correlation of ACD measured thru Smith method with Orbscan and Pentacam are R=0.958 and R=0.942 respectively and so Orbscan results can be used in procedures relying on ACD. Conclusion: ACDs measured with OrbScan is more precise than Pentacam and so can be more useful in some surgery procedures relying ACD results such as phakic IOLs and in cycloplegia contraindications.

Keywords: orbscan, pentacam, anterior chamber depth, slit lamp

Procedia PDF Downloads 356
499 Nano Fat Injection for Scar Treatment and Skin Rejuvenation

Authors: Sokol Isaraj, Lorela Bendo

Abstract:

Scars resulting from surgery, injury, or burns have a physical and psychological impact on the affected patient. Although a number of treatments are available, nano fat grafting is an effective treatment for scars. Nano fat is a liquid suspension rich in stem cells obtained by mechanical emulsification. Nano fat grafting was performed in 10 cases to correct rhytides, surgical scars, and post-burn scars between January 2022 and April 2022. Fat was aspirated from the lower abdomen or trochanteric region. After emulsification and filtration protocol, the resulting nano fat liquid was injected intradermally and subdermally. All patients filled out a questionnaire at three months post-treatment, which consisted of questions regarding the grade of improvement of skin and recommendation of the procedure. The clinical results were apparent between 2 and 3 weeks after the treatment. All patients confirmed an improvement in skin texture and quality. The most significant improvement was seen in pigmentation and pliability. No complications were reported. Nano fat seems to be a safe and effective treatment in scar treatment and skin rejuvenation.

Keywords: fat grafting, fat transfer, micro fat, nano fat

Procedia PDF Downloads 69
498 Evaluation of Cardiac Rhythm Patterns after Open Surgical Maze-Procedures from Three Years' Experiences in a Single Heart Center

Authors: J. Yan, B. Pieper, B. Bucsky, H. H. Sievers, B. Nasseri, S. A. Mohamed

Abstract:

In order to optimize the efficacy of medications, the regular follow-up with long-term continuous monitoring of heart rhythmic patterns has been facilitated since clinical introduction of cardiac implantable electronic monitoring devices (CIMD). Extensive analysis of rhythmic circadian properties is capable to disclose the distributions of arrhythmic events, which may support appropriate medication according rate-/rhythm-control strategy and minimize consequent afflictions. 348 patients (69 ± 0.5ys, male 61.8%) with predisposed atrial fibrillation (AF), undergoing primary ablating therapies combined to coronary or valve operations and secondary implantation of CIMDs, were involved and divided into 3 groups such as PAAF (paroxysmal AF) (n=99, male 68.7%), PEAF (persistent AF) (n=94, male 62.8%), and LSPEAF (long-standing persistent AF) (n=155, male 56.8%). All patients participated in three-year ambulant follow-up (3, 6, 9, 12, 18, 24, 30 and 36 months). Burdens of atrial fibrillation recurrence were assessed using cardiac monitor devices, whereby attacks frequencies and their circadian patterns were systemically analyzed. Anticoagulants and regular anti-arrhythmic medications were evaluated and the last were listed in terms of anti-rate and anti-rhythm regimens. Patients in the PEAF-group showed the least AF-burden after surgical ablating procedures compared to both of the other subtypes (p < 0.05). The AF-recurrences predominantly performed such attacks’ property as shorter than one hour, namely within 10 minutes (p < 0.05), regardless of AF-subtypes. Concerning circadian distribution of the recurrence attacks, frequent AF-attacks were mostly recorded in the morning in the PAAF-group (p < 0.05), while the patients with predisposed PEAF complained less attack-induced discomforts in the latter half of the night and the ones with LSPEAF only if they were not physically active after primary surgical ablations. Different AF-subtypes presented distinct therapeutic efficacies after appropriate surgical ablating procedures and recurrence properties in sense of circadian distribution. An optimization of medical regimen and drug dosages to maintain the therapeutic success needs more attention to detailed assessment of the long-term follow-up. Rate-control strategy plays a much more important role than rhythm-control in the ongoing follow-up examinations.

Keywords: atrial fibrillation, CIMD, MAZE, rate-control, rhythm-control, rhythm patterns

Procedia PDF Downloads 142
497 Recent Advancement in Dendrimer Based Nanotechnology for the Treatment of Brain Tumor

Authors: Nitin Dwivedi, Jigna Shah

Abstract:

Brain tumor is metastatic neoplasm of central nervous system, in most of cases it is life threatening disease with low survival rate. Despite of enormous efforts in the development of therapeutics and diagnostic tools, the treatment of brain tumors and gliomas remain a considerable challenge in the area of neuro-oncology. The most reason behind of this the presence of physiological barriers including blood brain barrier and blood brain tumor barrier, lead to insufficient reach ability of therapeutic agents at the site of tumor, result of inadequate destruction of gliomas. So there is an indeed need empowerment of brain tumor imaging for better characterization and delineation of tumors, visualization of malignant tissue during surgery, and tracking of response to chemotherapy and radiotherapy. Multifunctional different generations of dendrimer offer an improved effort for potentiate drug delivery at the site of brain tumor and gliomas. So this article emphasizes the innovative dendrimer approaches in tumor targeting, tumor imaging and delivery of therapeutic agent.

Keywords: blood brain barrier, dendrimer, gliomas, nanotechnology

Procedia PDF Downloads 545
496 Malpractice Makes Perfect: A Thematic Analysis on How Doctors Handle Medical Errors

Authors: Kathleen Joy Hingan, Jessiraye Luienne Catubigan, Carlo Mercado, Janisse RañEses

Abstract:

In this research, the researchers wanted to explore how specialists and resident doctors in the fields of surgery, and obstetrics and gynecology handle their medical errors. They are interested in understanding the factors that contributed to the disclosure of medical error, the feelings after the occurrence of an error, and the way they coped with it given the power relations in place. The researchers conducted semi-structured interviews, transcribed the recordings, and analyzed the transcripts using thematic analysis. They found that doctors disclosed to their superiors and co-residents to cope with and to learn from the errors. In terms of disclosure to patients, the participants told them about the adverse event, but not about the error because of fear for themselves, their colleagues, their institution, and their patient. Doctors also performed compensatory actions to make up for the error and the nondisclosure of its occurrence. These actions functioned as a form of damage control too. Resident doctors and specialists receive different sanctions because of the power structures in the system.

Keywords: coping, disclosure, doctors, interviews, medical errors, thematic analysis

Procedia PDF Downloads 278
495 Nano Fat Injection for Scar Treatment and Skin Rejuvenation

Authors: Sokol Isaraj, Lorela Bendo

Abstract:

Scars resulting from surgery, injury, or burns have a physical and psychological impact on the affected patient. Although a number of treatments are available, nano fat grafting is an effective treatment for scars. Nano fat is a liquid suspension rich in stem cells obtained by mechanical emulsification. Nano fat grafting was performed in 10 cases to correct rhytides, surgical scars and post-burn scars between January 2022 and April 2022. Fat was aspirated from the lower abdomen or trochanteric region. After emulsification and filtration protocol, the resulting nano fat liquid was injected intradermally and subdermally. All patients filled out a questionnaire at 3 months post-treatment which consisted of questions regarding the grade of improvement of skin and recommendation of the procedure. The clinical results were apparent between 2 and 3 weeks after the treatment. All patients confirmed an improvement in skin texture and quality. The most significant improvement was seen in pigmentation and pliability. No complications were reported. Nano fat seems to be a safe and effective treatment for scar treatment and skin rejuvenation.

Keywords: fat grafting, fat transfer, microfat, nanofat

Procedia PDF Downloads 67
494 Totally Implantable Venous Access Device for Long Term Parenteral Nutrition in a Patient with High Output Enterocutaneous Fistula Due to Advanced Malignancy

Authors: Puneet Goyal, Aarti Agarwal

Abstract:

Background and Objective: Nutritional support is an integral part of palliative care of advanced non-resectable abdominal malignancy patients, though is frequently neglected aspect. Non-Healing high output Entero-cutaneous fistulas sometimes require long term parenteral nutrition, to take care of catabolism and replacement of nutrients. We present a case of inoperable pancreatic malignancy with high output entero-cutaneous fistula, which was provided parenteral nutritional support with the use of Totally Implantable Venous Access Device (TIVAD). Method and Results: 55 year old man diagnosed with carcinoma pancreas had developed high entero-cutaneous fistula. His tumor was found to be inoperable and was on total parenteral nutrition through routine central line. This line was difficult to maintain as he required it for a long term TPN. He was planned to undergo Totally Implantable Venous Access Device (TIVAD) implantation. 8Fr single lumen catheter with Groshong non-return Valve (Bard Access Systems, Inc. USA) was inserted through right internal jugular vein, under fluoroscopic guidance. The catheter was tunneled subcutaneously and brought towards infraclavicular pocket, cut at appropriate length and connected to port and locked. Port was sutured in floor of pocket. Free flow of blood aspirated, flushed with heparinized saline. There was no kink observed in entire length of catheter under fluoroscopy. Skin over infraclavicular pocket was sutured. Long term catheter care and associated risks were explained to patient and relatives. Patient continued to receive total parenteral nutrition as well as other supportive therapy though TIVAD for next 6 weeks, till his demise. Conclusion: TIVADs are standard of care for long term venous access solutions in cancer patients requiring chemotherapy. In this case, we extended its use for providing parenteral nutrition and other supportive therapy. TIVADs can be implanted in advanced cancer patients for providing venous access solution required for various palliative treatments and medications. This will help in improving quality of life and satisfaction amongst terminally ill cancer patients.

Keywords: parenteral nutrition, totally implantable venous access device, long term venous access, interventions in anesthesiology

Procedia PDF Downloads 222
493 Dynamic Simulation of Disintegration of Wood Chips Caused by Impact and Collisions during the Steam Explosion Pre-Treatment

Authors: Muhammad Muzamal, Anders Rasmuson

Abstract:

Wood material is extensively considered as a raw material for the production of bio-polymers, bio-fuels and value-added chemicals. However, the shortcoming in using wood as raw material is that the enzymatic hydrolysis of wood material is difficult because the accessibility of enzymes to hemicelluloses and cellulose is hindered by complex chemical and physical structure of the wood. The steam explosion (SE) pre-treatment improves the digestion of wood material by creating both chemical and physical modifications in wood. In this process, first, wood chips are treated with steam at high pressure and temperature for a certain time in a steam treatment vessel. During this time, the chemical linkages between lignin and polysaccharides are cleaved and stiffness of material decreases. Then the steam discharge valve is rapidly opened and the steam and wood chips exit the vessel at very high speed. These fast moving wood chips collide with each other and with walls of the equipment and disintegrate to small pieces. More damaged and disintegrated wood have larger surface area and increased accessibility to hemicelluloses and cellulose. The energy required for an increase in specific surface area by same value is 70 % more in conventional mechanical technique, i.e. attrition mill as compared to steam explosion process. The mechanism of wood disintegration during the SE pre-treatment is very little studied. In this study, we have simulated collision and impact of wood chips (dimension 20 mm x 20 mm x 4 mm) with each other and with walls of the vessel. The wood chips are simulated as a 3D orthotropic material. Damage and fracture in the wood material have been modelled using 3D Hashin’s damage model. This has been accomplished by developing a user-defined subroutine and implementing it in the FE software ABAQUS. The elastic and strength properties used for simulation are of spruce wood at 12% and 30 % moisture content and at 20 and 160 OC because the impacted wood chips are pre-treated with steam at high temperature and pressure. We have simulated several cases to study the effects of elastic and strength properties of wood, velocity of moving chip and orientation of wood chip at the time of impact on the damage in the wood chips. The disintegration patterns captured by simulations are very similar to those observed in experimentally obtained steam exploded wood. Simulation results show that the wood chips moving with higher velocity disintegrate more. Moisture contents and temperature decreases elastic properties and increases damage. Impact and collision in specific directions cause easy disintegration. This model can be used to efficiently design the steam explosion equipment.

Keywords: dynamic simulation, disintegration of wood, impact, steam explosion pretreatment

Procedia PDF Downloads 388
492 A Flexible Piezoelectric - Polymer Composite for Non-Invasive Detection of Multiple Vital Signs of Human

Authors: Sarah Pasala, Elizabeth Zacharias

Abstract:

Vital sign monitoring is crucial for both everyday health and medical diagnosis. A significant factor in assessing a human's health is their vital signs, which include heart rate, breathing rate, blood pressure, and electrocardiogram (ECG) readings. Vital sign monitoring has been the focus of many system and method innovations recently. Piezoelectrics are materials that convert mechanical energy into electrical energy and can be used for vital sign monitoring. Piezoelectric energy harvesters that are stretchable and flexible can detect very low frequencies like airflow, heartbeat, etc. Current advancements in piezoelectric materials and flexible sensors have made it possible to create wearable and implantable medical devices that can continuously monitor physiological signals in humans. But because of their non-biocompatible nature, they also produce a large amount of e-waste and require another surgery to remove the implant. This paper presents a biocompatible and flexible piezoelectric composite material for wearable and implantable devices that offers a high-performance platform for seamless and continuous monitoring of human physiological signals and tactile stimuli. It also addresses the issue of e-waste and secondary surgery. A Lead-free piezoelectric, SrBi4Ti4O15, is found to be suitable for this application because the properties can be tailored by suitable substitutions and also by varying the synthesis temperature protocols. In the present work, SrBi4Ti4O15 modified by rare-earth has been synthesized and studied. Coupling factors are calculated from resonant (fr) and anti-resonant frequencies (fa). It is observed that Samarium substitution in SBT has increased the Curie temperature, dielectric and piezoelectric properties. From impedance spectroscopy studies, relaxation, and non-Debye type behaviour are observed. The composite of bioresorbable poly(l-lactide) and Lead-free rare earth modified Bismuth Layered Ferroelectrics leads to a flexible piezoelectric device for non-invasive measurement of vital signs, such as heart rate, breathing rate, blood pressure, and electrocardiogram (ECG) readings and also artery pulse signals in near-surface arteries. These composites are suitable to detect slight movement of the muscles and joints. This Lead-free rare earth modified Bismuth Layered Ferroelectrics – polymer composite is synthesized using a ball mill and the solid-state double sintering method. XRD studies indicated the two phases in the composite. SEM studies revealed the grain size to be uniform and in the range of 100 nm. The electromechanical coupling factor is improved. The elastic constants are calculated and the mechanical flexibility is found to be improved as compared to the single-phase rare earth modified Bismuth Latered piezoelectric. The results indicate that this composite is suitable for the non-invasive detection of multiple vital signs of humans.

Keywords: composites, flexible, non-invasive, piezoelectric

Procedia PDF Downloads 17
491 Cystic Ganglionosis in Child: Rare Entity

Authors: Jatinder Pal Singh, Harpreet Singh, Gagandeep Singh Digra, Mandeep Kaur Sidhu, Pawan Kumar

Abstract:

Introduction: Ganglion cyst is a benign condition in which there is a cystic lesion in relation to a joint or a tendon sheath arising from myxoid degeneration of fibrous connective tissue. These can be unilocular or multilocular. In rare cases, there may be multiple ganglion cysts, known as cystic ganglionosis. They can occur at any age but are commonly seen in adults. Clinically they may be asymptomatic or present as swelling or mass effect in adjacent structures. These are common in extremities such as hands and feet. Case Presentation: 11-year-old female child presented with slowly progressive painless swelling of her right hand since the age of 4. Antenatal and perinatal history was unremarkable. Her family history was negative. She denies fever, malaise, morning stiffness, weight loss, fatigue, restriction of joint movements, or any sensory and motor deficit. Lab parameters were negative for inflammatory or infectious etiology. No other joint or extremity involvement was present. On physical examination, the swelling was present on the dorsum and palmer aspect of the right hand and wrist. They were non-tender on palpation without any motor or sensory deficit. MRI hand revealed multiple well-defined fluid signal intensity cystic appearing lesions in periarticular/intraarticular locations in relation to distal radio-ulnar, radio-carpal, intercarpal, carpometacarpal, metacarpophalangeal and interphalangeal joints as well as peritendinous location around flexor tendons more so in the region of wrist, palm, 1st and 5th digit and along extensor tendons in the region of wrist, largest one noted along flexor pollicis longus tendon in thenar region and along 1st digit measuring approx. 4.6 x 1.2 x 1.2 centimeter. Pressure erosions and bone remodelling were noted in the bases of the 2nd to 5th metacarpals, capitate, trapezoid, the distal shaft of 1st metacarpal, and proximal phalanx of 1st digit. Marrow edema was noted in the base and proximal shaft of the 4th metacarpal and proximal shaft of the 3rd metacarpal – likely stress or pressure related. The patient was advised of aspiration, but the family refused the procedure. Therefore the patient was kept on conservative treatment. Conclusion: Cystic ganglionosis is a rare condition with very few cases reported in the medical literature. Its prevalence and association are not known because of the rarity of this condition. It should be considered as an important differential in patients presenting with soft tissue swelling in extremities. Treatment option includes conservative management, aspiration, and surgery. Aspiration has a high recurrence rate. Although surgery has a low recurrence rate, it carries a high rate of complications. Imaging with MRI is essential for confirmation of the cystic nature of lesions and their relation with the joint capsules or tendons. This helps in differentiating from other soft tissue lesions and presurgical planning.

Keywords: radiology, rare, cystic ganglionosis, child

Procedia PDF Downloads 62
490 Case Report on Anaesthesia for Ruptured Ectopic with Severe Pulmonary Hypertension in a Mute Patient

Authors: Pamela Chia, Tay Yoong Chuan

Abstract:

Introduction: Severe pulmonary hypertension (PH) patients requiring non-cardiac surgery risk have increased mortality rates ranging. These patients are plagued with cardiorespiratory failure, dysrhythmias and anticoagulation potentially with concurrent sepsis and renal insufficiency, perioperative morbidity. We present a deaf-mute patient with severe idiopathic PH emergently prepared for ruptured ectopic laparotomy. Case Report: A 20 year-old female, 62kg (BMI 25 kg/m2) with severe idiopathic PH (2DE Ejection Fraction was 41%, Pulmonary Artery Systolic Pressure (PASP) 105 mmHg, Right ventricle strain and hypertrophy) and selective mutism was rushed in for emergency laparotomy after presenting to the emergency department for abdominal pain. The patient had an NYHA Class II with room air SpO2 93-95%. While awaiting lung transplant, the patient takes warfarin, Sildanefil, Macitentan and even Selexipag for rising PASP. At presentation, vital signs: BP 95/63, HR 119 SpO2 88% (room air). Despite decreasing haemoglobin 14 to 10g/dL, INR 2.59 was reversed with prothrombin concentrate, and Vitamin K. ECG revealed Right Bundle Branch Block with right ventricular strain and x-ray showed cardiomegaly, dilated Right Ventricle, Pulmonary Arteries, basal atelectasis. Arterial blood gas showed compensated metabolic acidosis pH 7.4 pCO2 32 pO2 53 HCO3 20 BE -4 SaO2 88%. The cardiothoracic surgeon concluded no role for Extracorporeal Membrane Oxygenation (ECMO). We inserted invasive arterial and central venous lines with blood transfusion via an 18G cannula before the patient underwent a midline laparotomy, haemostasis of ruptured ovarian cyst with 2.4L of clots under general anesthesia and FloTrac cardiac output monitoring. Rapid sequence induction was done with Midazolam/Propofol, remifentanil infusion, and rocuronium. The patient was maintained on Desflurane. Blood products and colloids were transfused for further 1.5L blood loss. Postoperatively, the patient was transferred to the intensive care unit and was extubated uneventfully 7hours later. The patient went home a week later. Discussion: Emergency hemostasis laparotomy in anticoagulated WHO Class I PH patient awaiting lung transplant with no ECMO backup poses tremendous stress on the deaf-mute patient and the anesthesiologist. Balancing hemodynamics avoiding hypotension while awaiting hemostasis in the presence of pulmonary arterial dilators and anticoagulation requires close titration of volatiles, which decreases RV contractility. We review the contraindicated anesthetic agents (ketamine, N2O), choice of vasopressors in hypotension to maintain Aortic-right ventricular pressure gradients and nitric oxide use perioperatively. Conclusion: Interdisciplinary communication with a deaf-mute moribund patient and anesthesia considerations pose many rare challenges worth sharing.

Keywords: pulmonary hypertension, case report, warfarin reversal, emergency surgery

Procedia PDF Downloads 194
489 Influence of Coenzyme as a Corrosion Barrier for Biodegradable Magnesium

Authors: Minjung Park, Jimin Park, Youngwoon Kim, Hyungseop Han, Myoungryul Ok, Hojeong Jeon, Hyunkwang Seok, Yuchan Kim

Abstract:

Magnesium is an essential element in human body and has unique characteristics such as bioabsorbable and biodegradable properties. Therefore, there has been much attention on studies on the implants based on magnesium to avoid subsequent surgery. However, high amount of hydrogen gas is generated by relatively severe corrosion of magnesium especially in aqueous condition with chloride ions. And it contributes to the causes of swelling of skin and causes consequent inflammation of soft tissue where is directly in contact with implants. Therefore, there is still concern about the safety of the using biodegradable magnesium alloys, which is limited to various applications. In this study, we analyzed the influence of coenzyme on corrosion behavior of magnesium. The analysis of corrosion rate was held by using Hanks’ balanced salt solution (HBSS) as a body stimulated fluid and in condition of 37°C. Thus, with deferring the concentration of the coenzyme used in this study, corrosion rates from 0.0654ml/ cm² to 0.0438ml/cm² were observed in immersion tests. Also, comparable results were obtained in electrochemical tests. Results showed that hydrogen gas produced from corrosion of magnesium can be controlled.

Keywords: biodegradable magnesium, biomaterials, coenzyme, corrosion

Procedia PDF Downloads 397
488 Optimization of Artisanal Fishing Waste Fermentation for Volatile Fatty Acids Production

Authors: Luz Stella Cadavid-Rodriguez, Viviana E. Castro-Lopez

Abstract:

Fish waste (FW) has a high content of potentially biodegradable components, so it is amenable to be digested anaerobically. In this line, anaerobic digestion (AD) of FW has been studied for biogas production. Nevertheless, intermediate products such as volatile fatty acids (VFA), generated during the acidogenic stage, have been scarce investigated, even though they have a high potential as a renewable source of carbon. In the literature, there are few studies about the Inoculum-Substrate (I/S) ratio on acidogenesis. On the other hand, it is well known that pH is a critical factor in the production of VFA. The optimum pH for the production of VFA seems to change depending on the substrate and can vary in a range between 5.25 and 11. Nonetheless, the literature about VFA production from protein-rich waste, such as FW, is scarce. In this context, it is necessary to deepen on the determination of the optimal operating conditions of acidogenic fermentation for VFA production from protein-rich waste. Therefore, the aim of this research was to optimize the volatile fatty acid production from artisanal fishing waste, studying the effect of pH and the I/S ratio on the acidogenic process. For this research, the inoculum used was a methanogenic sludge (MS) obtained from a UASB reactor treating wastewater of a slaughterhouse plant, and the FW was collected in the port of Tumaco (Colombia) from the local artisanal fishers. The acidogenic fermentation experiments were conducted in batch mode, in 500 mL glass bottles as anaerobic reactors, equipped with rubber stoppers provided with a valve to release biogas. The effective volume used was 300 mL. The experiments were carried out for 15 days at a mesophilic temperature of 37± 2 °C and constant agitation of 200 rpm. The effect of 3 pH levels: 5, 7, 9, coupled with five I/S ratios, corresponding to 0.20, 0.15, 0.10, 0.05, 0.00 was evaluated taking as a response variable the production of VFA. A complete randomized block design was selected for the experiments in a 5x3 factorial arrangement, with two repetitions per treatment. At the beginning and during the process, pH in the experimental reactors was adjusted to the corresponding values of 5, 7, and 9 using 1M NaOH or 1M H2SO4, as was appropriated. In addition, once the optimum I/S ratio was determined, the process was evaluated at this condition without pH control. The results indicated that pH is the main factor in the production of VFA, obtaining the highest concentration with neutral pH. By reducing the I/S ratio, as low as 0.05, it was possible to maximize VFA production. Thus, the optimum conditions found were natural pH (6.6-7.7) and I/S ratio of 0.05, with which it was possible to reach a maximum total VFA concentration of 70.3 g Ac/L, whose major components were acetic acid (35%) and butyric acid (32%). The findings showed that the acidogenic fermentation of FW is an efficient way of producing VFA and that the operating conditions can be simple and economical.

Keywords: acidogenesis, artisanal fishing waste, inoculum to substrate ratio, volatile fatty acids

Procedia PDF Downloads 102
487 Ambivalence in Embracing Artificial Intelligence in the Units of a Public Hospital in South Africa

Authors: Sanele E. Nene L., Lia M. Hewitt

Abstract:

Background: Artificial intelligence (AI) has a high value in healthcare, various applications have been developed for the efficiency of clinical operations, such as appointment/surgery scheduling, diagnostic image analysis, prognosis, prediction and management of specific ailments. Purpose: The purpose of this study was to explore, describe, contrast, evaluate, and develop the various leadership strategies as a conceptual framework, applied by public health Operational Managers (OMs) to embrace AI benefits, with the aim to improve the healthcare system in a public hospital. Design and Method: A qualitative, exploratory, descriptive and contextual research design was followed and a descriptive phenomenological approach. Five phases were followed to conduct this study. Phenomenological individual interviews and focus groups were used to collect data and a phenomenological thematic data analysis method was used. Findings and conclusion: Three themes surfaced as the experiences of AI by the OMs; Positive experiences related to AI, Management and leadership processes in AI facilitation, and Challenges related to AI.

Keywords: ambivalence, embracing, Artificial intelligence, public hospital

Procedia PDF Downloads 59
486 Early Detection of Lymphedema in Post-Surgery Oncology Patients

Authors: Sneha Noble, Rahul Krishnan, Uma G., D. K. Vijaykumar

Abstract:

Breast-Cancer related Lymphedema is a major problem that affects many women. Lymphedema is the swelling that generally occurs in the arms or legs caused by the removal of or damage to lymph nodes as a part of cancer treatment. Treating it at the earliest possible stage is the best way to manage the condition and prevent it from leading to pain, recurrent infection, reduced mobility, and impaired function. So, this project aims to focus on the multi-modal approaches to identify the risks of Lymphedema in post-surgical oncology patients and prevent it at the earliest. The Kinect IR Sensor is utilized to capture the images of the body and after image processing techniques, the region of interest is obtained. Then, performing the voxelization method will provide volume measurements in pre-operative and post-operative periods in patients. The formation of a mathematical model will help in the comparison of values. Clinical pathological data of patients will be investigated to assess the factors responsible for the development of lymphedema and its risks.

Keywords: Kinect IR sensor, Lymphedema, voxelization, lymph nodes

Procedia PDF Downloads 119
485 A Nanofi Brous PHBV Tube with Schwann Cell as Artificial Nerve Graft Contributing to Rat Sciatic Nerve Regeneration across a 30-Mm Defect Bridge

Authors: Esmaeil Biazar

Abstract:

A nanofibrous PHBV nerve conduit has been used to evaluate its efficiency based on the promotion of nerve regeneration in rats. The designed conduits were investigated by physical, mechanical and microscopic analyses. The conduits were implanted into a 30-mm gap in the sciatic nerves of the rats. Four months after surgery, the regenerated nerves were evaluated by macroscopic assessments and histology. This polymeric conduit had sufficiently high mechanical properties to serve as a nerve guide. The results demonstrated that in the nanofibrous graft with cells, the sciatic nerve trunk had been reconstructed with restoration of nerve continuity and formatted nerve fibers with myelination. For the grafts especially the nanofibrous conduits with cells, muscle cells of gastrocnemius on the operated side were uniform in their size and structures. This study proves the feasibility of artificial conduit with Schwann cells for nerve regeneration by bridging a longer defect in a rat model.

Keywords: sciatic regeneration, Schwann cell, artificial conduit, nanofibrous PHBV, histological assessments

Procedia PDF Downloads 311
484 Influence of Ligature Tightening on Bone Fracture Risk in Interspinous Process Surgery

Authors: Dae Kyung Choi, Won Man Park, Kyungsoo Kim, Yoon Hyuk Kim

Abstract:

The interspinous process devices have been recently used due to its advantages such as minimal invasiveness and less subsidence of the implant to the osteoporotic bone. In this paper, we have analyzed the influences of ligature tightening of several interspinous process devices using finite element analysis. Four types of interspinous process implants were inserted to the L3-4 spinal motion segment based on their surgical protocols. Inferior plane of L4 vertebra was fixed and 7.5 Nm of extension moment were applied on superior plane of L3 vertebra with 400N of compressive load along follower load direction and pretension of the ligature. The stability of the spinal unit was high enough than that of intact model. The higher value of pretension in the ligature led the decrease of dynamic stabilization effect in cases of the WallisTM, DiamTM, Viking, and Spear®. The results of present study could be used to evaluate surgical option and validate the biomechanical characteristics of the spinal implants.

Keywords: interspinous process device, bone fracture risk, lumbar spine, finite element analysis

Procedia PDF Downloads 391
483 A New Second Tier Screening for Congenital Adrenal Hyperplasia Utilizing One Dried Blood Spot

Authors: Engy Shokry, Giancarlo La Marca, Maria Luisa Della Bona

Abstract:

Newborn screening for Congenital Adrenal Hyperplasia (CAH) relies on quantification of 17α-hydroxyprogesterone using enzyme immunoassays. These assays, in spite of being rapid, readily available and easy to perform, its reliability was found questionable due to lack of selectivity and specificity resulting in large number of false-positives, consequently family anxiety and associated hospitalization costs. To improve specificity of conventional 17α-hydroxyprogesterone screening which may experience false transient elevation in preterm, low birth weight or acutely ill neonates, steroid profiling by LC-MS/MS as a second-tier test was implemented. Unlike the previously applied LC-MS/MS methods, with the disadvantage of requiring a relatively high number of blood drops. Since newborn screening tests are increasing, it is necessary to minimize the sample volume requirement to make the maximum use of blood samples collected on filter paper. The proposed new method requires just one 3.2 mm dried blood spot (DBS) punch. Extraction was done using methanol: water: formic acid (90:10:0.1, v/v/v) containing deuterium labelled internal standards. Extracts were evaporated and reconstituted in 10 % acetone in water. Column switching strategy for on-line sample clean-up was applied to improve the chromatographic run. The first separative step retained the investigated steroids and passed through the majority of high molecular weight impurities. After the valve switching, the investigated steroids are back flushed from the POROS® column onto the analytical column and separated using gradient elution. Found quantitation limits were 5, 10 and 50 nmol/L for 17α-hydroxyprogesterone, androstenedione and cortisol respectively with mean recoveries of between 98.31-103.24 % and intra-/ inter-assay CV% < 10 % except at LLOQ. The method was validated using standard addition calibration and isotope dilution strategies. Reference ranges were determined by analysing samples from 896 infants of various ages at the time of sample collection. The method was also applied on patients with confirmed CAH. Our method represents an attractive combination of low sample volume requirement, minimal sample preparation time without derivatization and quick chromatography (5 min). The three steroid profile and the concentration ratios (17OHP + androstenedione/cortisol) allowed better screening outcomes of CAH reducing false positives, associated costs and anxiety.

Keywords: congenital adrenal hyperplasia (CAH), 17α-hydroxyprogesterone, androstenedione, cortisol, LC-MS/MS

Procedia PDF Downloads 424
482 A Prospective Study on the Efficacy of Mesenchymal Stem Cells in Intervertebral Disc Regeneration

Authors: Prabhu Thangaraju, Manoj Deepak, A. Sivakumar

Abstract:

Removal of inter vertebral disc along with spinal fusion has many disadvantages such as causing stress fractures. If it is possible regenerate the spine it would be possible avoid the complications of the surgery and achieve better results. Our study involves the use of mesenchymal stem cells in regenerating the discs. Our study involved 10 patients who presented with degenerative disc disease between 2008-2011 in our hospital. After adequate pre-operative check prepared mesenchymal stem cells were injected into the disc spaces. These patients were subjected to conservative therapy for a minimum of six weeks before they were accepted into the study. They were followed up regularly for a minimum of 2years with serial radiographs and MRI. 8 out of the 10 patients had completed reduction in the pain. The T2 weighted MRI images in 9 out of the 10 patients showed a bright signal compared the previous Images which indicated that there was improvement in the hydration levels. From the case study of 10 patients who were subjected to mesenchymal cell therapy in our hospital, we can conclude that the use of mesenchymal cells in treatment of intervertebral disc degeneration in a safe and effective option.

Keywords: mesenchymal stem cells, intervertebral disc, the spine, disc degeneration

Procedia PDF Downloads 355
481 Palliation of Pain in Pyomyositis: A Case Series and Literature Review

Authors: Katie Jerram, Jacqui Nevols, Rebecca Howes, Hayley Richardson, Debbie Suso, Thomas Batten, Reny Mathai

Abstract:

Pyomyositis is an uncommon acute purulent skeletal muscle infection, usually caused by Staphylococcus aureus, occurring either spontaneously or following local trauma. Immunocompromise is a risk factor. It presents with pyrexia, pain, and tenderness of the affected muscle, which may have a firm ‘woody’ feel. Management usually involves surgery and prolonged courses of antibiotics, but alongside these active treatments, palliation of symptoms such as pain is also a priority. A short case series of diabetic inpatients under the care of the Renal Medicine team with pyomyositis is presented, demonstrating that Hospital Palliative Care Teams may be well placed to provide symptom management advice by working jointly with the patient’s medical or surgical team. A review of the literature on the management of pain in pyomyositis is also presented, and there was no clear consensus on the best strategy. It may be that a combination of analgesics and adjuncts is the most effective strategy, perhaps combined with the holistic approach used within palliative care.

Keywords: pyomyositis, pain, palliation, analgesia

Procedia PDF Downloads 126
480 Chronic Hypertension, Aquaporin and Hydraulic Conductivity: A Perspective on Pathological Connections

Authors: Chirag Raval, Jimmy Toussaint, Tieuvi Nguyen, Hadi Fadaifard, George Wolberg, Steven Quarfordt, Kung-ming Jan, David S. Rumschitzki

Abstract:

Numerous studies examine aquaporins’ role in osmotic water transport in various systems but virtually none focus on aquaporins’ role in hydrostatically-driven water transport involving mammalian cells save for our laboratory’s recent study of aortic endothelial cells. Here we investigate aquaporin-1 expression and function in the aortic endothelium in two high-renin rat models of hypertension, the spontaneously hypertensive genomically altered Wystar-Kyoto rat variant and Sprague-Dawley rats made hypertensive by two kidney, one clip Goldblatt surgery. We measured aquaporin-1 expression in aortic endothelial cells from whole rat aortas by quantitative immunohistochemistry, and function by measuring the pressure driven hydraulic conductivities of excised rat aortas with both intact and denuded endothelia on the same vessel. We use them to calculate the effective intimal hydraulic conductivity, which is a combination of endothelial and subendothelial components. We observed well-correlated enhancements in aquaporin-1 expression and function in both hypertensive rat models as well as in aortas from normotensive rats whose expression was upregulated by 2h forskolin treatment. Upregulated aquaporin-1 expression and function may be a response to hypertension that critically determines conduit artery vessel wall viability and long-term susceptibility to atherosclerosis. Numerous studies examine aquaporins’ role in osmotic water transport in various systems but virtually none focus on aquaporins’ role in hydrostatically-driven water transport involving mammalian cells save for our laboratory’s recent study of aortic endothelial cells. Here we investigate aquaporin-1 expression and function in the aortic endothelium in two high-renin rat models of hypertension, the spontaneously hypertensive genomically altered Wystar-Kyoto rat variant and Sprague-Dawley rats made hypertensive by two kidney, one clip Goldblatt surgery. We measured aquaporin-1 expression in aortic endothelial cells from whole rat aortas by quantitative immunohistochemistry, and function by measuring the pressure driven hydraulic conductivities of excised rat aortas with both intact and denuded endothelia on the same vessel. We use them to calculate the effective intimal hydraulic conductivity, which is a combination of endothelial and subendothelial components. We observed well-correlated enhancements in aquaporin-1 expression and function in both hypertensive rat models as well as in aortas from normotensive rats whose expression was upregulated by 2h forskolin treatment. Upregulated aquaporin-1 expression and function may be a response to hypertension that critically determines conduit artery vessel wall viability and long-term susceptibility to atherosclerosis.

Keywords: acute hypertension, aquaporin-1, hydraulic conductivity, hydrostatic pressure, aortic endothelial cells, transcellular flow

Procedia PDF Downloads 213
479 Ocular Biometry: Common Etiologies of Difference More Than 0.33mm between Axial Lengths of the 2 Eyes

Authors: Ghandehari Motlagh, Mohammad

Abstract:

Purpose: We tried to find the most common etiologies for anisometropia in pre-op cataract cases: axial or refractive. Methods: In this cross-sectional study ,41 pre-op cataract eyes with more than 0.33 difference between axial lengths of 2 eyes were enrolled.Considered for each 1mm difference between axial lengths in long eyes( AXL more than 25):1.75-2.00 D of anisometropia, for normal eyes(AXL: 22- 25):2.50D and for short eyes (AXL less than 22):3.50-3.75 D as axial anisometropia. If there are more or lesser anisometropia, we recorded as refractive anisometropia. Results: Average of anisometropia :4.24 D, prevalence of PK or LK :1 (2.38%), kc:1(2.38%), glaucoma surgery: 1(2.38%), and pseudophakic status of the opposite eye 8(19.04%). Prevalence of axial anisometropia:21 (52.4%) and refractive anisometropia 20(47.6%).Then on basis of this study we can rely on the patient’s refraction exactly before phaco for evaluation of axial length differences between the 2 eyes, because most of the anisometropias are axial. Conclusion: In most cases, cataract does not induce significant change in refractive error (secondary myopia) and AXL difference between the 2 eyes are correlated with anisometropia.so it can be used for cataract patient’s ocular biometry evaluation. Pre-cataract refraction is a valuable variable should be measured and recorded in routin eye examination.

Keywords: ocular axial length, anisometropia, cataract, ophthalmology and optometry

Procedia PDF Downloads 364
478 Quick off the Mark with Achilles Tendon Rupture

Authors: Emily Moore, Andrew Gaukroger, Matthew Solan, Lucy Bailey, Alexandra Boxall, Andrew Carne, Chintu Gadamsetty, Charlotte Morley, Katy Western, Iwona Kolodziejczyk

Abstract:

Introduction: Rupture of the Achilles tendon is common and has a long recovery period. Most cases are managed non-operatively. Foot and Ankle Surgeons advise an ultrasound scan to check the gap between the torn ends. A large gap (with the ankle in equinus) is a relative indication for surgery. The definitive decision regarding surgical versus non-operative management can only be made once an ultrasound scan is undertaken and the patient is subsequently reviewed by a Foot and Ankle surgeon. To get to this point, the patient journey involves several hospital departments. In nearby trusts, patients reattend for a scan and go to the plaster room both before and after the ultrasound for removal and re-application of the cast. At a third visit to the hospital, the surgeon and patient discuss options for definitive treatment. It may take 2-3 weeks from the initial Emergency Department visit before the final treatment decision is made. This “wasted time” is ultimately added to the recovery period for the patient. In this hospital, Achilles rupture patients are seen in a weekly multidisciplinary OneStop Heel Pain clinic. This pathway was already efficient but subject to occasional frustrating delays if a key staff member was absent. A new pathway was introduced with the goal to reduce delays to a definitive treatment plan. Method: A retrospective series of Achilles tendon ruptures managed according to the 2019 protocol was identified. Time taken from the Emergency Department to have both an ultrasound scan and specialist Foot and Ankle surgical review were calculated. 30 consecutive patients were treated with our new pathway and prospectively followed. The time taken for a scan and for specialist review were compared to the 30 consecutive cases from the 2019 (pre-COVID) cohort. The new pathway includes 1. A new contoured splint applied to the front of the injured limb held with a bandage. This can be removed and replaced (unlike a plaster cast) in the ultrasound department, removing the need for plaster room visits. 2. Urgent triage to a Foot and Ankle specialist. 3. Ultrasound scan for assessment of rupture gap and deep vein thrombosis check. 4. Early decision regarding surgery. Transfer to weight bearing in a prosthetic boot in equinuswithout waiting for the once-a-week clinic. 5. Extended oral VTE prophylaxis. Results: The time taken for a patient to have both an ultrasound scan and specialist review fell > 50%. All patients in the new pathway reached a definitive treatment decision within one week. There were no significant differences in patient demographics or rates of surgical vs non-operative treatment. The mean time from Emergency Department visit to specialist review and ultrasound scan fell from 8.7 days (old protocol) to 2.9 days (new pathway). The maximum time for this fell from 23 days (old protocol) to 6 days (new pathway). Conclusion: Teamwork and innovation have improved the experience for patients with an Achilles tendon rupture. The new pathway brings many advantages - reduced time in the Emergency Department, fewer hospital visits, less time using crutches and reduced overall recovery time.

Keywords: orthopaedics, achilles rupture, ultrasound, innovation

Procedia PDF Downloads 100
477 Bone Marrow Edema Syndrome in the Foot and Ankle

Authors: S. Alireza Mirghasemi, Elly Trepman, Mohammad Saleh Sadeghi, Narges Rahimi Gabaran, Shervin Rashidinia

Abstract:

Bone marrow edema syndrome (BMES) is an uncommon and self-limited syndrome characterized by atraumatic extremity pain with unknown of etiology. Symptom onset may include sudden or gradual swelling and pain at rest or during activity, usually at night. This syndrome mostly affects middle-aged men and younger women who have pain in the lower extremities. The most common sites involved with BMES, in decreasing order of frequency, are the bones about the hip, knee, ankle, and foot. The diagnosis of BMES is made with magnetic resonance imaging to exclude other causes of bone marrow edema. The correct diagnosis often is delayed because of the low prevalence and nonspecific signs in the foot and ankle. This delay may intensify bone pain and impair patient function and quality of life. The goal of BMES treatment is to relieve pain and shorten disease duration. Treatment options are limited and may include symptomatic treatment, pharmacologic treatment, and surgery.

Keywords: transient osteoporosis, bone marrow edema syndrome, iloprost, bisphosphonates

Procedia PDF Downloads 349
476 The Effectiveness and Accuracy of the Schulte Holt IOL Toric Calculator Processor in Comparison to Manually Input Data into the Barrett Toric IOL Calculator

Authors: Gabrielle Holt

Abstract:

This paper is looking to prove the efficacy of the Schulte Holt IOL Toric Calculator Processor (Schulte Holt ITCP). It has been completed using manually inputted data into the Barrett Toric Calculator and comparing the number of minutes taken to complete the Toric calculations, the number of errors identified during completion, and distractions during completion. It will then compare that data to the number of minutes taken for the Schulte Holt ITCP to complete also, using the Barrett method, as well as the number of errors identified in the Schulte Holt ITCP. The data clearly demonstrate a momentous advantage to the Schulte Holt ITCP and notably reduces time spent doing Toric Calculations, as well as reducing the number of errors. With the ever-growing number of cataract surgeries taking place around the world and the waitlists increasing -the Schulte Holt IOL Toric Calculator Processor may well demonstrate a way forward to increase the availability of ophthalmologists and ophthalmic staff while maintaining patient safety.

Keywords: Toric, toric lenses, ophthalmology, cataract surgery, toric calculations, Barrett

Procedia PDF Downloads 70
475 Functional Outcome of Speech, Voice and Swallowing Following Excision of Glomus Jugulare Tumor

Authors: B. S. Premalatha, Kausalya Sahani

Abstract:

Background: Glomus jugulare tumors arise within the jugular foramen and are commonly seen in females particularly on the left side. Surgical excision of the tumor may cause lower cranial nerve deficits. Cranial nerve involvement produces hoarseness of voice, slurred speech, and dysphagia along with other physical symptoms, thereby affecting the quality of life of individuals. Though oncological clearance is mainly emphasized on while treating these individuals, little importance is given to their communication, voice and swallowing problems, which play a crucial part in daily functioning. Objective: To examine the functions of voice, speech and swallowing outcomes of the subjects, following excision of glomus jugulare tumor. Methods: Two female subjects aged 56 and 62 years had come with a complaint of change in voice, inability to swallow and reduced clarity of speech following surgery for left glomus jugulare tumor were participants of the study. Their surgical information revealed multiple cranial nerve palsies involving the left facial, left superior and recurrent branches of the vagus nerve, left pharyngeal, left soft palate, left hypoglossal and vestibular nerves. Functional outcomes of voice, speech and swallowing were evaluated by perceptual and objective assessment procedures. Assessment included the examination of oral structures and functions, dysarthria by Frenchey dysarthria assessment, cranial nerve functions and swallowing functions. MDVP and Dr. Speech software were used to evaluate acoustic parameters of voice and quality of voice respectively. Results: The study revealed that both the subjects, subsequent to excision of glomus jugulare tumor, showed a varied picture of affected oral structure and functions, articulation, voice and swallowing functions. The cranial nerve assessment showed impairment of the vagus, hypoglossal, facial and glossopharyngeal nerves. Voice examination indicated vocal cord paralysis associated with breathy quality of voice, weak voluntary cough, reduced pitch and loudness range, and poor respiratory support. Perturbation parameters as jitter, shimmer were affected along with s/z ratio indicative of voice fold pathology. Reduced MPD(Maximum Phonation Duration) of vowels indicated that disturbed coordination between respiratory and laryngeal systems. Hypernasality was found to be a prominent feature which reduced speech intelligibility. Imprecise articulation was seen in both the subjects as the hypoglossal nerve was affected following surgery. Injury to vagus, hypoglossal, gloss pharyngeal and facial nerves disturbed the function of swallowing. All the phases of swallow were affected. Aspiration was observed before and during the swallow, confirming the oropharyngeal dysphagia. All the subsystems were affected as per Frenchey Dysarthria Assessment signifying the diagnosis of flaccid dysarthria. Conclusion: There is an observable communication and swallowing difficulty seen following excision of glomus jugulare tumor. Even with complete resection, extensive rehabilitation may be necessary due to significant lower cranial nerve dysfunction. The finding of the present study stresses the need for involvement of as speech and swallowing therapist for pre-operative counseling and assessment of functional outcomes.

Keywords: functional outcome, glomus jugulare tumor excision, multiple cranial nerve impairment, speech and swallowing

Procedia PDF Downloads 234
474 Correlation of Clinical and Sonographic Findings with Cytohistology for Diagnosis of Ovarian Tumours

Authors: Meenakshi Barsaul Chauhan, Aastha Chauhan, Shilpa Hurmade, Rajeev Sen, Jyotsna Sen, Monika Dalal

Abstract:

Introduction: Ovarian masses are common forms of neoplasm in women and represent 2/3rd of gynaecological malignancies. A pre-operative suggestion of malignancy can guide the gynecologist to refer women with suspected pelvic mass to a gynecological oncologist for appropriate therapy and optimized treatment, which can improve survival. In the younger age group preoperative differentiation into benign or malignant pathology can decide for conservative or radical surgery. Imaging modalities have a definite role in establishing the diagnosis. By using International Ovarian Tumor Analysis (IOTA) classification with sonography, costly radiological methods like Magnetic Resonance Imaging (MRI) / computed tomography (CT) scan can be reduced, especially in developing countries like India. Thus, this study is being undertaken to evaluate the role of clinical methods and sonography for diagnosis of the nature of the ovarian tumor. Material And Methods: This prospective observational study was conducted on 40 patients presenting with ovarian masses, in the Department of Obstetrics and Gynaecology, at a tertiary care center in northern India. Functional cysts were excluded. Ultrasonography and color Doppler were performed on all the cases.IOTA rules were applied, which take into account locularity, size, presence of solid components, acoustic shadow, dopper flow etc . Magnetic Resonance Imaging (MRI) / computed tomography (CT) scans abdomen and pelvis were done in cases where sonography was inconclusive. In inoperable cases, Fine needle aspiration cytology (FNAC) was done. The histopathology report after surgery and cytology report after FNAC was correlated statistically with the pre-operative diagnosis made clinically and sonographically using IOTA rules. Statistical Analysis: Descriptive measures were analyzed by using mean and standard deviation and the Student t-test was applied and the proportion was analyzed by applying the chi-square test. Inferential measures were analyzed by sensitivity, specificity, negative predictive value, and positive predictive value. Results: Provisional diagnosis of the benign tumor was made in 16(42.5%) and of the malignant tumor was made in 24(57.5%) patients on the basis of clinical findings. With IOTA simple rules on sonography, 15(37.5%) were found to be benign, while 23 (57.5%) were found to be malignant and findings were inconclusive in 2 patients (5%). FNAC/Histopathology reported that benign ovarian tumors were 14 (35%) and 26(65%) were malignant, which was taken as the gold standard. The clinical finding alone was found to have a sensitivity of 66.6% and a specificity of 90.9%. USG alone had a sensitivity of 86% and a specificity of 80%. When clinical findings and IOTA simple rules of sonography were combined (excluding inconclusive masses), the sensitivity and specificity were 83.3% and 92.3%, respectively. While including inconclusive masses, sensitivity came out to be 91.6% and specificity was 89.2. Conclusion: IOTA's simple sonography rules are highly sensitive and specific in the prediction of ovarian malignancy and also easy to use and easily reproducible. Thus, combining clinical examination with USG will help in the better management of patients in terms of time, cost and better prognosis. This will also avoid the need for costlier modalities like CT, and MRI.

Keywords: benign, international ovarian tumor analysis classification, malignant, ovarian tumours, sonography

Procedia PDF Downloads 66
473 Model and Neural Control of the Depth of Anesthesia during Surgery

Authors: Javier Fernandez, Mayte Medina, Rafael Fernandez de Canete, Nuria Alcain, Juan Carlos Ramos-Diaz

Abstract:

At present, the experimentation of anesthetic drugs on patients requires a regulation protocol, and the response of each patient to several doses of entry drug must be well known. Therefore, the development of pharmacological dose control systems is a promising field of research in anesthesiology. In this paper, it has been developed a non-linear compartmental the pharmacokinetic-pharmacodynamical model which describes the anesthesia depth effect in a sufficiently reliable way over a set of patients with the depth effect quantified by the Bi-Spectral Index. Afterwards, an Artificial Neural Network (ANN) predictive controller has been designed based on the depth of anesthesia model so as to keep the patient in the optimum condition while he undergoes surgical treatment. For the purpose of quantifying the efficiency of the neural predictive controller, a classical proportional-integral-derivative controller has also been developed to compare both strategies. Results show the superior performance of predictive neural controller during BiSpectral Index reference tracking.

Keywords: anesthesia, bi-spectral index, neural network control, pharmacokinetic-pharmacodynamical model

Procedia PDF Downloads 320
472 Adaptive Environmental Control System Strategy for Cabin Air Quality in Commercial Aircrafts

Authors: Paolo Grasso, Sai Kalyan Yelike, Federico Benzi, Mathieu Le Cam

Abstract:

The cabin air quality (CAQ) in commercial aircraft is of prime interest, especially in the context of the COVID-19 pandemic. Current Environmental Control Systems (ECS) rely on a prescribed fresh airflow per passenger to dilute contaminants. An adaptive ECS strategy is proposed, leveraging air sensing and filtration technologies to ensure a better CAQ. This paper investigates the CAQ level achieved in commercial aircraft’s cabin during various flight scenarios. The modeling and simulation analysis is performed in a Modelica-based environment describing the dynamic behavior of the system. The model includes the following three main systems: cabin, recirculation loop and air-conditioning pack. The cabin model evaluates the thermo-hygrometric conditions and the air quality in the cabin depending on the number of passengers and crew members, the outdoor conditions and the conditions of the air supplied to the cabin. The recirculation loop includes models of the recirculation fan, ordinary and novel filtration technology, mixing chamber and outflow valve. The air-conditioning pack includes models of heat exchangers and turbomachinery needed to condition the hot pressurized air bled from the engine, as well as selected contaminants originated from the outside or bled from the engine. Different ventilation control strategies are modeled and simulated. Currently, a limited understanding of contaminant concentrations in the cabin and the lack of standardized and systematic methods to collect and record data constitute a challenge in establishing a causal relationship between CAQ and passengers' comfort. As a result, contaminants are neither measured nor filtered during flight, and the current sub-optimal way to avoid their accumulation is their dilution with the fresh air flow. However, the use of a prescribed amount of fresh air comes with a cost, making the ECS the most energy-demanding non-propulsive system within an aircraft. In such a context, this study shows that an ECS based on a reduced and adaptive fresh air flow, and relying on air sensing and filtration technologies, provides promising results in terms of CAQ control. The comparative simulation results demonstrate that the proposed adaptive ECS brings substantial improvements to the CAQ in terms of both controlling the asymptotic values of the concentration of the contaminant and in mitigating hazardous scenarios, such as fume events. Original architectures allowing for adaptive control of the inlet air flow rate based on monitored CAQ will change the requirements for filtration systems and redefine the ECS operation.

Keywords: cabin air quality, commercial aircraft, environmental control system, ventilation

Procedia PDF Downloads 84
471 Degradation Kinetics of Cardiovascular Implants Employing Full Blood and Extra-Corporeal Circulation Principles: Mimicking the Human Circulation In vitro

Authors: Sara R. Knigge, Sugat R. Tuladhar, Hans-Klaus HöFfler, Tobias Schilling, Tim Kaufeld, Axel Haverich

Abstract:

Tissue engineered (TE) heart valves based on degradable electrospun fiber scaffold represent a promising approach to overcome the known limitations of mechanical or biological prostheses. But the mechanical stress in the high-pressure system of the human circulation is a severe challenge for the delicate materials. Hence, the prediction of the scaffolds` in vivo degradation kinetics must be as accurate as possible to prevent fatal events in future animal or even clinical trials. Therefore, this study investigates whether long-term testing in full blood provides more meaningful results regarding the degradation behavior than conventional tests in simulated body fluids (SBF) or Phosphate Buffered Saline (PBS). Fiber mats were produced from a polycaprolactone (PCL)/tetrafluoroethylene solution by electrospinning. The morphology of the fiber mats was characterized via scanning electron microscopy (SEM). A maximum physiological degradation environment utilizing a test set-up with porcine full blood was established. The set-up consists of a reaction vessel, an oxygenator unit, and a roller pump. The blood parameters (pO2, pCO2, temperature, and pH) were monitored with an online test system. All tests were also carried out in the test circuit with SBF and PBS to compare conventional degradation media with the novel full blood setting. The polymer's degradation is quantified by SEM picture analysis, differential scanning calorimetry (DSC), and Raman spectroscopy. Tensile and cyclic loading tests were performed to evaluate the mechanical integrity of the scaffold. Preliminary results indicate that PCL degraded slower in full blood than in SBF and PBS. The uptake of water is more pronounced in the full blood group. Also, PCL preserved its mechanical integrity longer when degraded in full blood. Protein absorption increased during the degradation process. Red blood cells, platelets, and their aggregates adhered on the PCL. Presumably, the degradation led to a more hydrophilic polymeric surface which promoted the protein adsorption and the blood cell adhesion. Testing degradable implants in full blood allows for developing more reliable scaffold materials in the future. Material tests in small and large animal trials thereby can be focused on testing candidates that have proven to function well in an in-vivo-like setting.

Keywords: Electrospun scaffold, full blood degradation test, long-term polymer degradation, tissue engineered aortic heart valve

Procedia PDF Downloads 134