Search results for: turbidity removal
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 550

Search results for: turbidity removal

550 Effectiveness of Moringa oleifera Coagulant Protein as Natural Coagulant aid in Removal of Turbidity and Bacteria from Turbid Waters

Authors: B. Bina, M.H. Mehdinejad, Gunnel Dalhammer, Guna RajaraoM. Nikaeen, H. Movahedian Attar

Abstract:

Coagulation of water involves the use of coagulating agents to bring the suspended matter in the raw water together for settling and the filtration stage. Present study is aimed to examine the effects of aluminum sulfate as coagulant in conjunction with Moringa Oleifera Coagulant Protein as coagulant aid on turbidity, hardness, and bacteria in turbid water. A conventional jar test apparatus was employed for the tests. The best removal was observed at a pH of 7 to 7.5 for all turbidities. Turbidity removal efficiency was resulted between % 80 to % 99 by Moringa Oleifera Coagulant Protein as coagulant aid. Dosage of coagulant and coagulant aid decreased with increasing turbidity. In addition, Moringa Oleifera Coagulant Protein significantly has reduced the required dosage of primary coagulant. Residual Al+3 in treated water were less than 0.2 mg/l and meets the environmental protection agency guidelines. The results showed that turbidity reduction of % 85.9- % 98 paralleled by a primary Escherichia coli reduction of 1-3 log units (99.2 – 99.97%) was obtained within the first 1 to 2 h of treatment. In conclusions, Moringa Oleifera Coagulant Protein as coagulant aid can be used for drinking water treatment without the risk of organic or nutrient release. We demonstrated that optimal design method is an efficient approach for optimization of coagulation-flocculation process and appropriate for raw water treatment.

Keywords: MOCP, Coagulant aid, turbidity removal, E.coliremoval, water, treatment

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3479
549 Application of Moringa oleifera Seed in Removing Colloids from Turbid Wastewater

Authors: H. Zemmouri, H. Lounic, N. Mameri

Abstract:

The present study aims to investigate the performance of Moringa oleifera seed extract as natural coagulant in clarification of secondary wastewater treatment plant (MWWTP) located in East of Algiers, Algeria. Coagulation flocculation performance of Moringa oleifera was evaluated through supernatant residual turbidity after jar test trials. Various influence parameters namely Moringa oleifera dosage and pH have been considered. Tests on Reghaia wastewater, having 129 NTU of initial turbidity, showed a removal of 69.45% of residual turbidity with only 1.5 mg/l of Moringa oleifera. This sufficient removal capability encourages the use of this bioflocculant for treatment of turbid waters. Indeed, Moringa oleifera which is a natural resource available locally (South of Algeria) coupled to the non-toxicity, biocompatibility and biodegradability, may be a very interesting alternative to the conventional coagulants used so far.

Keywords: Coagulation flocculation, colloids, Moringa oleifera, secondary wastewater.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2139
548 Pilot Scale Investigation on the Removal of Pollutants from Secondary Effluent to Meet Botswana Irrigation Standards Using Roughing and Slow Sand Filters

Authors: Moatlhodi Wise Letshwenyo, Lesedi Lebogang

Abstract:

Botswana is an arid country that needs to start reusing wastewater as part of its water security plan. Pilot scale slow sand filtration in combination with roughing filter was investigated for the treatment of effluent from Botswana International University of Science and Technology to meet Botswana irrigation standards. The system was operated at hydraulic loading rates of 0.04 m/hr and 0.12 m/hr. The results show that the system was able to reduce turbidity from 262 Nephelometric Turbidity Units to a range between 18 and 0 Nephelometric Turbidity Units which was below 30 Nephelometric Turbidity Units threshold limit. The overall efficacy ranged between 61% and 100%. Suspended solids, Biochemical Oxygen Demand, and Chemical Oxygen Demand removal efficiency averaged 42.6%, 45.5%, and 77% respectively and all within irrigation standards. Other physio-chemical parameters were within irrigation standards except for bicarbonate ion which averaged 297.7±44 mg L-1 in the influent and 196.22±50 mg L-1 in the effluent which was above the limit of 92 mg L-1, therefore averaging a reduction of 34.1% by the system. Total coliforms, fecal coliforms, and Escherichia coli in the effluent were initially averaging 1.1 log counts, 0.5 log counts, and 1.3 log counts respectively compared to corresponding influent log counts of 3.4, 2.7 and 4.1, respectively. As time passed, it was observed that only roughing filter was able to reach reductions of 97.5%, 86% and 100% respectively for faecal coliforms, Escherichia coli, and total coliforms. These organism numbers were observed to have increased in slow sand filter effluent suggesting multiplication in the tank. Water quality index value of 22.79 for the physio-chemical parameters suggests that the effluent is of excellent quality and can be used for irrigation purposes. However, the water quality index value for the microbial parameters (1820) renders the quality unsuitable for irrigation. It is concluded that slow sand filtration in combination with roughing filter is a viable option for the treatment of secondary effluent for reuse purposes. However, further studies should be conducted especially for the removal of microbial parameters using the system.

Keywords: Irrigation, roughing filter, slow sand filter, turbidity, water quality index.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 820
547 Parameter Sensitivity Analysis of Artificial Neural Network for Predicting Water Turbidity

Authors: Chia-Ling Chang, Chung-Sheng Liao

Abstract:

The present study focuses on the discussion over the parameter of Artificial Neural Network (ANN). Sensitivity analysis is applied to assess the effect of the parameters of ANN on the prediction of turbidity of raw water in the water treatment plant. The result shows that transfer function of hidden layer is a critical parameter of ANN. When the transfer function changes, the reliability of prediction of water turbidity is greatly different. Moreover, the estimated water turbidity is less sensitive to training times and learning velocity than the number of neurons in the hidden layer. Therefore, it is important to select an appropriate transfer function and suitable number of neurons in the hidden layer in the process of parameter training and validation.

Keywords: Artificial Neural Network (ANN), sensitivity analysis, turbidity.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2755
546 Effect of a Gravel Bed Flocculator on the Efficiency of a Low Cost Water Treatment Plants

Authors: Alaa Hussein Wadi

Abstract:

The principal objective of a water treatment plant is to produce water that satisfies a set of drinking water quality standards at a reasonable price to the consumers. The gravel-bed flocculator provide a simple and inexpensive design for flocculation in small water treatment plants (less than 5000 m3/day capacity). The packed bed of gravel provides ideal conditions for the formation of compact settleable flocs because of continuous recontact provided by the sinuous flow of water through the interstices formed by the gravel. The field data which were obtained from the operation of the water supply treatment unit cover the physical, chemical and biological water qualities of the raw and settled water as obtained by the operation of the treatment unit. The experiments were carried out with the aim of assessing the efficiency of the gravel filter in removing the turbidity, pathogenic bacteria, from the raw water. The water treatment plant, which was constructed for the treatment of river water, was in principle a rapid sand filter. The results show that the average value of the turbidity level of the settled water was 4.83 NTU with a standard deviation of turbidity 2.893 NTU. This indicated that the removal efficiency of the sedimentation tank (gravel filter) was about 67.8 %. for pH values fluctuated between 7.75 and 8.15, indicating the alkaline nature of the raw water of the river Shatt Al-Hilla, as expected. Raw water pH is depressed slightly following alum coagulation. The pH of the settled water ranged from 7.75 to a maximum of 8.05. The bacteriological tests which were carried out on the water samples were: total coliform test, E-coli test, and the plate count test. In each test the procedure used was as outlined in the Standard Methods for the Examination of Water and Wastewater (APHA, AWWA, and WPCF, 1985). The gravel filter exhibit a low performance in removing bacterial load. The percentage bacterial removal, which is maximum for total plate count (19%) and minimum for total coliform (16.82%).

Keywords: Gravel bed flocculator, turbidity, total coliform.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2613
545 Conditioning Process of Fresh Activated Sludge

Authors: Salam K Al-Dawery, Mustafa S Nasser

Abstract:

The effect of polyelectrolytes; cationic and anionic charges and coagulants have been investigated for fresh activated sludge at different concentrations and pH values in a comparative fashion. The results from the experiments indicate that the cationic polyelectrolytes have a significant effluence on the sludge characteristic, degree of flocculation and water quality such as turbidity and SVI. The results show that the cationic CPAM-80 is the most effective polyelectrolyte used corresponding to turbidity and SVI despite of the variations in feed properties of the fresh activated sludge.

Keywords: Coagulant, Polyelectrolyte, Settling volume index, Turbidity.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1672
544 The role of pH on Cr(VI) Reduction and Removal by Arthrobacter Viscosus

Authors: B. Silva, H. Figueiredo, I. C. Neves, T. Tavares

Abstract:

Arthrobacter viscosus biomass was used for Cr(VI) biosorption. The effect of pH on Cr(VI) reduction and removal from aqueous solution was studied in the range of 1-4. The Cr(VI) removal involves both redox reaction and adsorption of metal ions on biomass surface. The removal rate of Cr(VI) was enhanced by very acid conditions, while higher solution pH values favored the removal of total chromium. The best removal efficiency and uptake were reached at pH 4, 72.5 % and 12.6 mgCr/gbiomass, respectively.

Keywords: Biosorption, chromium, pH, reduction.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1606
543 Groundwater Quality Improvement by Using Aeration and Filtration Methods

Authors: Nik N. Nik Daud, Nur H. Izehar, B. Yusuf, Thamer A. Mohamed, A. Ahsan

Abstract:

An experiment was conducted using two aeration methods (water-into-air and air-into-water) and followed by filtration processes using manganese greensand material. The properties of groundwater such as pH, dissolved oxygen, turbidity and heavy metal concentration (iron and manganese) will be assessed. The objectives of this study are i) to determine the effective aeration method and ii) to assess the effectiveness of manganese greensand as filter media in removing iron and manganese concentration in groundwater. Results showed that final pH for all samples after treatment are in range from 7.40 and 8.40. Both aeration methods increased the dissolved oxygen content. Final turbidity for groundwater samples are between 3 NTU to 29 NTU. Only three out of eight samples achieved iron concentration of 0.3mg/L and less and all samples reach manganese concentration of 0.1mg/L and less. Air-into-water aeration method gives higher percentage of iron and manganese removal compare to water-into-air method.

Keywords: Aeration, filtration, groundwater, water quality.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4050
542 Characterization of Candlenut Shells and Its Application to Remove Oil and Fine Solids of Produced Water in Nutshell Filters of Water Cleaning Plant

Authors: Annur Suhadi, Haris B. Harahap, Zaim Arrosyidi, Epan, Darmapala

Abstract:

Oilfields under waterflood often face the problem of plugging injectors either by internal filtration or external filter cake built up inside pore throats. The content of suspended solids shall be reduced to required level of filtration since corrective action of plugging is costly expensive. The performance of nutshell filters, where filtration takes place, is good using pecan and walnut shells. Candlenut shells were used instead of pecan and walnut shells since they were abundant in Indonesia, Malaysia, and East Africa. Physical and chemical properties of walnut, pecan, and candlenut shells were tested and the results were compared. Testing, using full-scale nutshell filters, was conducted to determine the oil content, turbidity, and suspended solid removal, which was based on designed flux rate. The performance of candlenut shells, which were deeply bedded in nutshell filters for filtration process, was monitored. Cleaned water outgoing nutshell filters had total suspended solids of 17 ppm, while oil content could be reduced to 15.1 ppm. Turbidity, using candlenut shells, was below the specification for injection water, which was less than 10 Nephelometric Turbidity Unit (NTU). Turbidity of water, outgoing nutshell filter, was ranged from 1.7-5.0 NTU at various dates of operation. Walnut, pecan, and candlenut shells had moisture content of 8.98 wt%, 10.95 wt%, and 9.95 wt%, respectively. The porosity of walnut, pecan, and candlenut shells was significantly affected by moisture content. Candlenut shells had property of toluene solubility of 7.68 wt%, which was much higher than walnut shells, reflecting more crude oil adsorption. The hardness of candlenut shells was 2.5-3 Mohs, which was close to walnut shells’ hardness. It was advantage to guarantee the cleaning filter cake by fluidization process during backwashing.

Keywords: Candlenut shells, walnut shells, pecan shells, nutshell filter, filtration.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 391
541 The Effect of Global Solar Variations on the Performance of n-AlGaAs/p-GaAs Solar Cells

Authors: A. Guechi, M. Chegaar

Abstract:

This study investigates how AlGaAs/GaAs thin film solar cells perform under varying global solar spectrum due to the changes of environmental parameters such as the air mass and the atmospheric turbidity. The solar irradiance striking the solar cell is simulated using the spectral irradiance model SMARTS2 (Simple Model of the Atmospheric Radiative Transfer of Sunshine) for clear skies on the site of Setif (Algeria). The results show a reduction in the short circuit current due to increasing atmospheric turbidity, it is 63.09% under global radiation. However increasing air mass leads to a reduction in the short circuit current of 81.73%. The efficiency decreases with increasing atmospheric turbidity and air mass.

Keywords: AlGaAs/GaAs, Solar Cells, Environmental parameters, Spectral Variation, SMARTS.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2161
540 Removal of Heavy Metals from Wastewater by Adsorption and Membrane Processes: a Comparative Study

Authors: Nermen N. Maximous, George F. Nakhla, W. K. Wan

Abstract:

This research aimed at investigating the Cr (III), Cd (II) and Pb (II) removal efficiencies by using the newly synthesized metal oxides/ polyethersulfone (PES), Al2O3/PES and ZrO2/PES, membranes from synthetic wastewater and exploring fouling mechanisms. A Comparative study between the removal efficiencies of Cr (III), Cd (II) and Pb (II) from synthetic and natural wastewater by using adsorption onto agricultural by products and the newly synthesized Al2O3/PES and ZrO2/PES membranes was conducted to assess the advantages and limitations of using the metal oxides/PES membranes for heavy metals removal. The results showed that about 99 % and 88 % removal efficiencies were achieved by the tested membranes for Pb (II) and Cr (III), respectively.

Keywords: Adsorption, metals removal, ultrafiltrationmembranes, wastewater

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 5629
539 Effect of Addition of Separan at Different Concentrations as a Flocculants on Quality of Sugar Cane Juice

Authors: Ghada A. Abdel-Razig , Isam A. Mohamed Ahmed, Elfadil E. Babiker & Abu ElGasim A. Yagoub

Abstract:

The study was designed to evaluate the use of low concentrations of separan flocculent (Less than 3 ppm) on physicochemical properties of sugar cane juice. Colour, pH, purity, turbidity, pol, brix, reducing sugars tannins and polyphenols of crushed cane (green and burned) juice, mixed juice and clarified juice were studied. The results showed that pol, brix, reducing sugar and turbidity are higher in crushed cane juice. Clarified burned juice had low turbidity, reducing sugars, pol and brix but had significantly lower pH, purity and colour when compared to crushed juice. Polyphenols of the crushed juice (1.19%) decreased significantly in the clarified juice to 0.006%. Addition of separan at a concentration of 0.015 ppm reduced significantly colour, polyphenols and tannins and reducing sugar compared to the control.

Keywords: Separan, Sugar cane, Reducing sugar, Polyphenols, Clarified juice.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2889
538 Effects of SRT and HRT on Treatment Performance of MBR and Membrane Fouling

Authors: M. I. Aida Isma, Azni Idris, Rozita Omar, A. R. Putri Razreena

Abstract:

40L of hollow fiber membrane bioreactor with solids retention times (SRT) of 30, 15 and 4 days were setup for treating synthetic wastewater at hydraulic retention times (HRT) of 12, 8 and 4 hours. The objectives of the study were to investigate the effects of SRT and HRT on membrane fouling. A comparative analysis was carried out for physiochemical quality parameters (turbidity, suspended solids, COD, NH3-N and PO43-). Scanning electron microscopy (SEM), energy diffusive X-ray (EDX) analyzer and particle size distribution (PSD) were used to characterize the membrane fouling properties. The influence of SRT on the quality of effluent, activated sludge quality, and membrane fouling were also correlated. Lower membrane fouling and slower rise in trans-membrane pressure (TMP) were noticed at the longest SRT and HRT of 30d and 12h, respectively. Increasing SRT results in noticeable reduction of dissolved organic matters. The best removal efficiencies of COD, TSS, NH3-N and PO43- were 93%, 98%, 80% and 30% respectively. The high HRT with shorter SRT induced faster fouling rate. The main fouling resistance was cake layer. The most severe membrane fouling was observed at SRT and HRT of 4 and 12, respectively with thickness cake layer of 17mm as reflected by higher TMP, lower effluent removal and thick sludge cake layer.

 

Keywords: Membrane bioreactor, SRT, HRT, membrane fouling.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 6163
537 Functionalized Nanoparticles as Sorbents for Removal of Toxic Species

Authors: Jerina Majeed, Jayshree Ramkumar, S. Chandramouleeswaran, A. K. Tyagi

Abstract:

Removal of various toxic species from aqueous streams is of great importance. Sorption is one of the important remediation procedures as it involves the use of cheap and easily available materials. Also the advantage of regeneration of the sorbent involves the possibility of using novel sorbents. Nanosorbents are very important as the removal is based on the surface phenomena and this is greatly affected by surface charge and area. Functionalization has been very important to bring about the removal of metal ions with greater selectivity.

Keywords: Mercury, lead, thiol functionalization, ZnO NPs.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2187
536 Flocculation on the Treatment of Olive Oil Mill Wastewater: Pretreatment

Authors: G. Hodaifa, J. A. Páez, C. Agabo, E. Ramos, J. C. Gutiérrez, A. Rosal

Abstract:

Currently, continuous two-phase decanter process used for olive oil production is the more internationally widespread. The wastewaters generated from this industry (OMW) are a real environmental problem because of its high organic load. Among proposed treatments for these wastewaters, advanced oxidation technologies (Fenton, ozone, photoFenton, etc.) are the most favourable. The direct application of these processes is somewhat expensive. Therefore, the application of a previous stage based on a flocculation-sedimentation operation is of high importance. In this research five commercial flocculants (three cationic, and two anionic) have been used to achieve the separation of phases (liquid clarifiedsludge). For each flocculant, different concentrations (0-1000 mg/L) have been studied. In these experiments, sludge volume formed and the final water quality were determined. The final removal percentages of total phenols (11.3-25.1%), COD (5.6-20.4%), total carbon (2.3-26.5%), total organic carbon (1.50-23.8%), total nitrogen (1.45-24.8%), and turbidity (27.9-61.4%) were determined. The variation on electric conductivity reduction percentage (1-8%) was also determined. Finally, the best flocculants with highest removal percentages have been determined (QG2001 and Flocudex CS49).

Keywords: Flocculants, flocculation, olive oil mill wastewater, water quality.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2502
535 Nutrients Removal Control via an Intermittently Aerated Membrane Bioreactor

Authors: Junior B. N. Adohinzin, Ling Xu

Abstract:

Nitrogen is among the main nutrients encouraging the growth of organic matter and algae which cause eutrophication in water bodies. Therefore, its removal from wastewater has become a worldwide emerging concern. In this research, an innovative Membrane Bioreactor (MBR) system named “moving bed membrane bioreactor (MBMBR)” was developed and investigated under intermittently-aerated mode for simultaneous removal of organic carbon and nitrogen.

Results indicated that the variation of the intermittently aerated duration did not have an apparent impact on COD and NH4+–N removal rate, yielding the effluent with average COD and NH4+–N removal efficiency of more than 92 and 91% respectively. However, in the intermittently aerated cycle of (continuously aeration/0s mix), (aeration 90s/mix 90s) and (aeration 90s/mix 180s); the average TN removal efficiency was 67.6%, 69.5% and 87.8% respectively. At the same time, their nitrite accumulation rate was 4.5%, 49.1% and 79.4% respectively. These results indicate that the intermittently aerated mode is an efficient way to controlling the nitrification to stop at nitrition; and also the length of anoxic duration is a key factor in improving TN removal.

Keywords: Membrane bioreactor (MBR), Moving bed biofilm reactor (MBBR), Nutrients removal, Simultaneous nitrification and denitrification.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2441
534 Arsenate Removal by Nano Zero-valent Iron in the Gas Bubbling System

Authors: V. Tanboonchuy, J.C. Hsu, N. Grisdanurak, C.H. Liao

Abstract:

This study focused on arsenate removal by nano zero-valent iron (NZVI) in the gas-bubbled aqueous solution. It appears that solution acidified by H2SO4 is far more favorable than by CO2-bubbled acidification. In addition, as dissolved oxygen was stripped out of solution by N2 gas bubbling, the arsenate removal dropped significantly. To take advantages of common practice of carbonation and oxic condition, pretreatment of CO2 and air bubbling in sequence are recommended for a better removal of arsenate.

Keywords: Arsenic, arsenate, zero-valent iron.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1653
533 Removal of Iron from Groundwater by Sulfide Precipitation

Authors: H. Jusoh, N. Sapari, R.Z. Raja Azie

Abstract:

Iron in groundwater is one of the problems that render the water unsuitable for drinking. The concentration above 0.3 mg/L is common in groundwater. The conventional method of removal is by precipitation under oxic condition. In this study, iron removal under anaerobic conditions was examined by batch experiment as a main purpose. The process involved by purging of groundwater samples with H2S to form iron sulfide. Removal up to 83% for 1 mg/L iron solution was achieved. The removal efficiency dropped to 82% and 75% for the higher initial iron concentrations 3.55 and 5.01 mg/L, respectively. The average residual sulfide concentration in water after the process was 25*g/L. The Eh level during the process was -272 mV. The removal process was found to follow the first order reaction with average rate constant of 4.52 x 10-3. The half-life for the concentrations to reduce from initial values was 157 minutes.

Keywords: Anaerobic, chemical kinetics, hydrogen sulfide, iron, rate constant

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2667
532 Effect of Influent COD on Biological Ammonia Removal Efficiency

Authors: S. H. Mirhossaini, H. Godini, A. Jafari

Abstract:

Biological Ammonia removal (nitrification), the oxidation of ammonia to nitrate catalyzed by bacteria, is a key part of global nitrogen cycling. In the first step of nitrification, chemolithoautotrophic ammonia oxidizer transform ammonia to nitrite, this subsequently oxidized to nitrate by nitrite oxidizing bacteria. This process can be affected by several factors. In this study the effect of influent COD on biological ammonia removal in a bench-scale biological reactor was investigated. Experiments were carried out using synthetic wastewater. The initial ammonium concentration was 25mgNH4 +-N L-1. The effect of COD between 247.55±1.8 and 601.08±3.24mgL-1 on biological ammonia removal was investigated by varying the COD loading supplied to reactor. From the results obtained in this study it could be concluded in the range of 247.55±1.8 to 351.35±2.05mgL-1, there is a direct relationship between amount of COD and ammonia removal. However more than 351.35±2.05 up to 601.08±3.24mgL-1 were found an indirect relationship between them.

Keywords: Ammonia biological removal, Nitrification, InfluentCOD.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3831
531 Comparison of Chemical Coagulation and Electrocoagulation for Boron Removal from Synthetic Wastewater Using Aluminium

Authors: Kartikaningsih Danis, Yao-Hui Huang

Abstract:

Various techniques including conventional and advanced have been employed for the boron treatment from water and wastewater. The electrocoagulation involves an electrolytic reactor for coagulation/flotation with aluminium as anode and cathode. There is aluminium as coagulant to be used for removal which may induce secondary pollution in chemical coagulation. The purpose of this study is to investigate and compare the performance between electrocoagulation and chemical coagulation on boron removal from synthetic wastewater. The effect of different parameters, such as pH reaction, coagulant dosage, and initial boron concentration were examined. The results show that the boron removal using chemical coagulation was lower. At the optimum condition (e.g. pH 8 and 0.8 mol coagulant dosage), boron removal efficiencies for chemical coagulation and electrocoagulation were 61% and 91%, respectively. In addition, the electrocoagulation needs no chemical reagents and makes the boron treatment easy for application.

Keywords: Electrocoagulation, chemical coagulation, aluminum electrode, boron removal.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1671
530 Biodegradation of Cyanide by a Novel Cyanidedegrading Bacterium

Authors: S. Potivichayanon, R. Kitleartpornpairoat

Abstract:

The objectives were to identify cyanide-degrading bacteria and study cyanide removal efficiency. Agrobacterium tumefaciens SUTS 1 was isolated. This is a new strain of microorganisms for cyanide degradation. The maximum growth rate of SUTS 1 obtained 4.7 × 108 CFU/ml within 4 days. The cyanide removal efficiency was studied at 25, 50, and 150 mg/L cyanide. The residual cyanide, ammonia, nitrate, nitrite, pH, and cell counts were analyzed. At 25 and 50 mg/L cyanide, SUTS 1 obtained similar removal efficiency approximately 87.50%. At 150 mg/L cyanide, SUTS 1 enhanced the cyanide removal efficiency up to 97.90%. Cell counts of SUTS 1 increased when the cyanide concentration was set at lower. The ammonia increased when the removal efficiency increased. The nitrate increased when the ammonia decreased but the nitrite did not detect in all experiments. pH values also increased when the cyanide concentrations were set at higher.

Keywords: Biodegradation, Cyanide-degrading bacteria, Removal efficiency, Residual cyanide

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2471
529 The Removal of As(V) from Drinking Waters by Coagulation Process using Iron Salts

Authors: M. Donmez, F. Akbal

Abstract:

In this study arsenate [As(V)] removal from drinking water by coagulation process was investigated. Ferric chloride (FeCl3.6H2O) and ferrous sulfate (FeSO4.7H2O) were used as coagulant. The effects of major operating variables such as coagulant dose (1–30 mg/L) and pH (5.5–9.5) were investigated. Ferric chloride and ferrous sulfate were found as effective and reliable coagulant due to required dose, residual arsenate and coagulant concentration. Optimum pH values for maximum arsenate removal for ferrous sulfate and ferric chloride were found as 8 and 7.5. The arsenate removal efficiency decreased at neutral and acidic pH values for Fe(II) and at the high acidic and high alkaline pH for Fe(III). It was found that the increase of coagulant dose caused a substantial increase in the arsenate removal. But above a certain ferric chloride and ferrous sulfate dosage, the increase in arsenate removal was not significant. Ferric chloride and ferrous sulfate dose above 8 mg/L slightly increased arsenate removal.

Keywords: Arsenic removal, coagulation, ıron salts, drinking water.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2109
528 Decolorization and COD Removal of Palm Oil Mill Wastewater by Electrocoagulation

Authors: K. Sontaya, B. Pitiyont, V. Punsuvon

Abstract:

The objective of this study is to investigate the performance of the electrocoagulation process for color and COD removal in palm oil wastewater using a 10 L batch reactor. Iron was used as electrodes and the distance between electrodes was 2 cm. The effects of operating parameters: current voltage (6, 12 and 18 volt), reaction time (5, 15, 30, 45 and 60 min) and initial pH (4 and 9) of treatment efficiency were examine. The result showed that decolorization and COD removal efficiency increased with the increase in current voltage and reaction time. The proper condition for decolorization achieved at initial pH 4 and 9 were current voltage of 12 volt, reaction time 30 min. The decolorization efficiency reached 90.4% and 88.9%, respectively. COD removal was achiveved at current voltage 12 volt, reaction time 15 min. COD removal efficiency was 89.2 % and 83.0%, respectively. From the results, to show electrocoagulation process can treat palm oil mill wastewater in both acidic and basic condition at high efficiency for color and COD removal. Consequently, electrocoagulation process can be used or applied as a post-treatment step to improve the quality of the final discharge in term of color and residual COD removal.

Keywords: COD removal, decolorizaton, electrocoagulation, iron electrode, palm oil mill wastewater.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3128
527 New Corneal Reflection Removal Method Used In Iris Recognition System

Authors: Walid Aydi, Nouri Masmoudi, Lotfi Kamoun

Abstract:

Images of human iris contain specular highlights due to the reflective properties of the cornea. This corneal reflection causes many errors not only in iris and pupil center estimation but also to locate iris and pupil boundaries especially for methods that use active contour. Each iris recognition system has four steps: Segmentation, Normalization, Encoding and Matching. In order to address the corneal reflection, a novel reflection removal method is proposed in this paper. Comparative experiments of two existing methods for reflection removal method are evaluated on CASIA iris image databases V3. The experimental results reveal that the proposed algorithm provides higher performance in reflection removal.

Keywords: iris, pupil, specular highlights, reflection removal

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3158
526 Scope of BOD, Nitrogen and Phosphorous Removal through Plant-Soil Interaction in the Wetland

Authors: Debabrata Mazumder

Abstract:

Constructed and natural wetlands are being used extensively to treat different types of wastewater including the domestic one. Considerable removal efficiency has been achieved for a variety of pollutants like BOD, nitrogen and phosphorous in the wetlands. Wetland treatment appears to be the best choice for treatment or pre-treatment of wastewater because of the low maintenance cost and simplicity of operation. Wetlands are the natural exporters of organic carbon on account of decomposition of organic matter. The emergent plants like reeds, bulrushes and cattails are commonly used in constructed wetland for the treatment process providing surface for bacterial growth, filtration of solids, nutrient uptake and oxygenation to promote nitrification as well as denitrification. The present paper explored different scopes of organic matter (BOD), nitrogen and phosphorous removal from wastewater through wetlands. Emphasis is given to look into the soil chemistry for tracing the behavior of carbon, nitrogen and phosphorus in the wetland. Due consideration is also made to see the viability for upgrading the BOD, nitrogen and phosphorus removal efficiency through different classical modifications of wetland.

Keywords: BOD removal, modification, nitrogen removal, phosphorous removal, wetland.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2690
525 Removal of Arsenic (III) from Contaminated Waterby Synthetic Nano Size Zerovalent Iron

Authors: A. R. Rahmani, H. R. Ghaffari, M. T. Samadi

Abstract:

The present work was conducted for Arsenic (III) removal, which one of the most poisonous groundwater pollutants, by synthetic nano size zerovalent iron (nZVI). Batch experiments were performed to investigate the influence of As (III), nZVI concentration, pH of solution and contact time on the efficiency of As (III) removal. nZVI was synthesized by reduction of ferric chloride by sodium borohydrid. SEM and XRD were used to determine particle size and characterization of produced nanoparticles. Up to 99.9% removal efficiency for arsenic (III) was obtained by nZVI dosage of 1 g/L at time equal to 10 min. and pH=7. It could be concluded that the removal efficiency were enhanced with increasing of ZVI dosage and reaction time, but decreased with increasing of arsenic concentration and pH for nano sized ZVI. nZVI presented an outstanding ability to remove As (III) due to not only a high surface area and low particle size but also to high inherent activity.

Keywords: Arsenic removal, aqueous solution, zero valent iron.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2566
524 Investigation of Advanced Oxidation Process for the Removal of Residual Carbaryl from Drinking Water Resources

Authors: Ali Reza Rahmani, Mohamad Taghi Samadi, Maryam Khodadadi

Abstract:

A laboratory set-up was designed to survey the effectiveness of UV/O3 advanced oxidation process (AOP) for the removal of Carbaryl from polluted water in batch reactor. The study was carried out by UV/O3 process for water samples containing 1 to 20 mg/L of Carbaryl in distilled water. Also the range of drinking water resources adjusted in synthetic water and effects of contact time, pH and Carbaryl concentration were studied. The residual pesticide concentration was determined by applying high performance liquid chromatography (HPLC). The results indicated that increasing of retention time and pH, enhances pesticide removal efficiency. The removal efficiency has been affected by pesticide initial concentration. Samples with low pesticide concentration showed a remarkable removal efficiency compared to the samples with high pesticide concentration. AOP method showed the removal efficiencies of 80% to 100%. Although process showed high performance for removal of pesticide from water samples, this process has different disadvantages including complication, intolerability, difficulty of maintenance and equipmental and structural requirements.

Keywords: AOP, Carbaryl, Pesticides, Water treatment.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2321
523 Removal of Elemental Mercury from Dry Methane Gas with Manganese Oxides

Authors: Junya Takenami, Md. Azhar Uddin, Eiji Sasaoka, Yasushi Shioya, Tsuneyoshi Takase

Abstract:

In this study, we sought to investigate the mercury removal efficiency of manganese oxides from natural gas. The fundamental studies on mercury removal with manganese oxides sorbents were carried out in a laboratory scale fixed bed reactor at 30 °C with a mixture of methane (20%) and nitrogen gas laden with 4.8 ppb of elemental mercury. Manganese oxides with varying surface area and crystalline phase were prepared by conventional precipitation method in this study. The effects of surface area, crystallinity and other metal oxides on mercury removal efficiency were investigated. Effect of Ag impregnation on mercury removal efficiency was also investigated. Ag supported on metal oxide such titania and zirconia as reference materials were also used in this study for comparison. The characteristics of mercury removal reaction with manganese oxide was investigated using a temperature programmed desorption (TPD) technique. Manganese oxides showed very high Hg removal activity (about 73-93% Hg removal) for first time use. Surface area of the manganese oxide samples decreased after heat-treatment and resulted in complete loss of Hg removal ability for repeated use after Hg desorption in the case of amorphous MnO2, and 75% loss of the initial Hg removal activity for the crystalline MnO2. Mercury desorption efficiency of crystalline MnO2 was very low (37%) for first time use and high (98%) after second time use. Residual potassium content in MnO2 may have some effect on the thermal stability of the adsorbed Hg species. Desorption of Hg from manganese oxides occurs at much higher temperatures (with a peak at 400 °C) than Ag/TiO2 or Ag/ZrO2. Mercury may be captured on manganese oxides in the form of mercury manganese oxide.

Keywords: Mercury removal, Metal and metal oxide sorbents, Methane, Natural gas.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2053
522 The removal of Ni, Cu and Fe from a Mixed Metal System using Sodium Hypophosphite as a Reducing Agent

Authors: Promise Sethembiso Ngema, Freeman Ntuli, Mohamed Belaid

Abstract:

The main objective of this study was to remove and recover Ni, Cu and Fe from a mixed metal system using sodium hypophosphite as a reducing agent and nickel powder as seeding material. The metal systems studied consisted of Ni-Cu, Ni-Fe and Ni-Cu-Fe solutions. A 5 L batch reactor was used to conduct experiments where 100 mg/l of each respective metal was used. It was found that the metals were reduced to their elemental form with removal efficiencies of over 80%. The removal efficiency decreased in the order Fe>Ni>Cu. The metal powder obtained contained between 97-99% Ni and was almost spherical and porous. Size enlargement by aggregation was the dominant particulate process.

Keywords: crystallization, electroless plating, heavy metal removal, wastewater treatment

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1987
521 Removal of Chromium from Aqueous Solution using Synthesized Polyaniline in Acetonitrile

Authors: Majid Riahi Samani, Seyed Mehdi Borghei

Abstract:

Absorptive characteristics of polyaniline synthesized in mixture of water and acetonitrile in 50/50 volume ratio was studied. Synthesized polyaniline in powder shape is used as an adsorbent to remove toxic hexavalent chromium from aqueous solutions. Experiments were conducted in batch mode with different variables such as agitation time, solution pH and initial concentration of hexavalent chromium. Removal mechanism is the combination of surface adsorption and reduction. The equilibrium time for removal of Cr(T) and Cr(VI) was about 2 and 10 minutes respectively. The optimum pH for total chromium removal occurred at pH 7 and maximum hexavalent chromium removal took place under acidic condition at pH 3. Investigating the isothermal characteristics showed that the equilibrium adsorption data fitted both Freundlich-s and Langmuir-s isotherms. The maximum adsorption of chromium was calculated 36.1 mg/g for polyaniline

Keywords: Polyaniline, Chromium, acetonitrile, Adsorption

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2185