Search results for: blood pressure
1590 White Blood Cells Identification and Counting from Microscopic Blood Image
Authors: Lorenzo Putzu, Cecilia Di Ruberto
Abstract:
The counting and analysis of blood cells allows the evaluation and diagnosis of a vast number of diseases. In particular, the analysis of white blood cells (WBCs) is a topic of great interest to hematologists. Nowadays the morphological analysis of blood cells is performed manually by skilled operators. This involves numerous drawbacks, such as slowness of the analysis and a nonstandard accuracy, dependent on the operator skills. In literature there are only few examples of automated systems in order to analyze the white blood cells, most of which only partial. This paper presents a complete and fully automatic method for white blood cells identification from microscopic images. The proposed method firstly individuates white blood cells from which, subsequently, nucleus and cytoplasm are extracted. The whole work has been developed using MATLAB environment, in particular the Image Processing Toolbox.Keywords: Automatic detection, Biomedical image processing, Segmentation, White blood cell analysis.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 89041589 Hypertension and Its Association with Oral Health Status in Adults: A Pilot Study in Padusunan Adults Community
Authors: Murniwati, Nurul Khairiyah, Putri Ovieza Maizar
Abstract:
The association between general and oral health is clearly important, particularly in adults with medical conditions. Many of the medical systemic conditions are either caused or aggravated by poor oral hygiene and vice versa. Hypertension is one of common medical systemic problem which has been a public health concern worldwide due to its known consequences. Those consequences must be related to oral health status as well, whether it may cause or worsen the oral health conditions. The objective of this study was to find out the association between hypertension and oral health status in adults. This study was an analytical observational study by using cross-sectional method. A total of 42 adults both male and female in Padusunan Village, Pariaman, West Sumatra, Indonesia were selected as subjects by using purposive sampling. Manual sphygmomanometer was used to measure blood pressure and dental examination was performed to calculate the decayed, missing, and filled teeth (DMFT) scores in order to represent oral health status. The data obtained was analyzed statistically using One Way ANOVA to determine the association between hypertensive adults and their oral health status. The result showed that majority age of the subjects was ranging from 51-70 years (40.5%). Based on blood pressure examination, 57.1% of subjects were classified to prehypertension. Overall, the mean of DMFT score calculated in normal, prehypertension and hypertension group was not considered statistically significant. There was no significant association (p>0.05) between hypertension and oral health status in adults.Keywords: Blood pressure, hypertension, DMFT, oral health status.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 17731588 Valuation on MEMS Pressure Sensors and Device Applications
Authors: Nurul Amziah Md Yunus, Izhal Abdul Halin, Nasri Sulaiman, Noor Faezah Ismail, Ong Kai Sheng
Abstract:
The MEMS pressure sensor has been introduced and presented in this paper. The types of pressure sensor and its theory of operation are also included. The latest MEMS technology, the fabrication processes of pressure sensor are explored and discussed. Besides, various device applications of pressure sensor such as tire pressure-monitoring system, diesel particulate filter and others are explained. Due to further miniaturization of the device nowadays, the pressure sensor with nanotechnology (NEMS) is also reviewed. The NEMS pressure sensor is expected to have better performance as well as lower in its cost. It has gained an excellent popularity in many applications.Keywords: Pressure sensor, diaphragm, MEMS, automotive application, biomedical application, NEMS.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 56861587 Non-Invasive Capillary Blood Flow Measurement: Laser Speckle and Laser Doppler
Authors: A.K.Jayanthy, N.Sujatha, M.Ramasubba Reddy
Abstract:
Microcirculation is essential for the proper supply of oxygen and nutritive substances to the biological tissue and the removal of waste products of metabolism. The determination of blood flow in the capillaries is therefore of great interest to clinicians. A comparison has been carried out using the developed non-invasive, non-contact and whole field laser speckle contrast imaging (LSCI) based technique and as well as a commercially available laser Doppler blood flowmeter (LDF) to evaluate blood flow at the finger tip and elbow and is presented here. The LSCI technique gives more quantitative information on the velocity of blood when compared to the perfusion values obtained using the LDF. Measurement of blood flow in capillaries can be of great interest to clinicians in the diagnosis of vascular diseases of the upper extremities.Keywords: Blood flow, Laser Doppler flowmeter, LSCI, speckle
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 25661586 Development of Monitoring Blood Bank Center Based PIC Microcontroller Using CAN Communication
Authors: Kaiwan S. Ismael, Ergun Ercelebi, Majeed Nader
Abstract:
This paper describes the design and implementation of a hardware setup for online monitoring of 24 refrigerators inside blood bank center using the microcontroller and CAN bus for communications between each node. Due to the security of locations in the blood bank hall and difficulty of monitoring of each refrigerator separately, this work proposes a solution to monitor all the blood bank refrigerators in one location. CAN-bus system is used because it has many applications and advantages, especially for this system due to easy in use, low cost, providing a reduction in wiring, fast to repair and easily expanding the project without a problem.
Keywords: Control Area Network (CAN), monitoring blood bank center, PIC microcontroller, MPLAB IDE.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 24831585 Effects of a Nectandra Membranacea Extract on Labeling of Blood Constituents with Technetium-99m and on the Morphology of Red Blood Cells
Authors: Silvana R.F. Moreno, Jorge J. Carvalho, Ana L. Nascimento, Mario Pereira, Luiz Q. A. Caldas, Mário Bernardo-Filho
Abstract:
The aim of this in vitro study was to evaluate the possible interference of a Nectandra membranacea extract (i) on the labeling of blood cells (BC), (ii) on the labeling process of BC and plasma (P) proteins with technetium-99m (Tc-99m) and (iii) on the morphology of red blood cells (RBC). Blood samples were incubated with a Nectandra membranacea crude extract, stannous chloride, Tc- 99m (sodium pertechnetate) was added, and soluble (SF) and insoluble (IF) fractions were isolated. Morphometry studies were performed with blood samples incubated with Nectandra membranacea extract. The results show that the Nectandra membranacea extract does not promote significant alteration of the labeling of BC, IF-P and IF-BC. The Nectandra membranacea extract was able to alter the erythrocyte membrane morphology, but these morphological changes were not capable to interfere on the labeling of blood constituents with Tc-99m.
Keywords: in vitro study, Nectandra membranacea, red bloodcell, technetium-99m
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 16591584 An AFM Approach of RBC Micro and Nanoscale Topographic Features during Storage
Authors: K. Santacruz-Gomez, E. Silva-Campa, S. Álvarez-García, V. Mata-Haro, D. Soto-Puebla, M. Pedroza-Montero
Abstract:
Blood gamma irradiation is the only available method to prevent transfusion associated graft versus host disease (TAGVHD). However, when blood is irradiated, determine blood shelf time is crucial. Non irradiated blood have a self-time from 21 to 35 days when is preserved with anticoagulated solution and stored at 4°C. During their storage, red blood cells (RBC) undergo a series of biochemical, biomechanical and molecular changes involving what is known as storage lesion (SL). SL include loss of structural integrity of RBC, decrease of 2,3-diphosphatidylglyceric acid levels, and increase of both ion potassium concentration and hemoglobin (Hb). On the other hand, Atomic force Microscopy (AFM) represents a versatile tool for a nano-scale high resolution topographic analysis in biological systems. In order to evaluate SL in irradiated and nonirradiated blood, RBC topography and morphometric parameters were obtained from an AFM XE-BIO system. Cell viability was followed using flow cytometry. Our results showed that early markers as nanoscale roughness, allow us to evaluate blood quality since other perspective.
Keywords: AFM, Blood γ-irradiation, roughness, Storage lesion.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 26971583 Blood Cell Dynamics in a Simple Shear Flow using an Implicit Fluid-Structure Interaction Method Based on the ALE Approach
Authors: Choeng-Ryul Choi, Chang-Nyung Kim, Tae-Hyub Hong
Abstract:
A numerical method is developed for simulating the motion of particles with arbitrary shapes in an effectively infinite or bounded viscous flow. The particle translational and angular motions are numerically investigated using a fluid-structure interaction (FSI) method based on the Arbitrary-Lagrangian-Eulerian (ALE) approach and the dynamic mesh method (smoothing and remeshing) in FLUENT ( ANSYS Inc., USA). Also, the effects of arbitrary shapes on the dynamics are studied using the FSI method which could be applied to the motions and deformations of a single blood cell and multiple blood cells, and the primary thrombogenesis caused by platelet aggregation. It is expected that, combined with a sophisticated large-scale computational technique, the simulation method will be useful for understanding the overall properties of blood flow from blood cellular level (microscopic) to the resulting rheological properties of blood as a mass (macroscopic).Keywords: Blood Flow, Fluid-Structure Interaction (FSI), Micro-Channels, Arbitrary Shapes, Red Blood Cells (RBCs)
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 23101582 Kalman Filter Based Adaptive Reduction of Motion Artifact from Photoplethysmographic Signal
Authors: S. Seyedtabaii, L. Seyedtabaii
Abstract:
Artifact free photoplethysmographic (PPG) signals are necessary for non-invasive estimation of oxygen saturation (SpO2) in arterial blood. Movement of a patient corrupts the PPGs with motion artifacts, resulting in large errors in the computation of Sp02. This paper presents a study on using Kalman Filter in an innovative way by modeling both the Artillery Blood Pressure (ABP) and the unwanted signal, additive motion artifact, to reduce motion artifacts from corrupted PPG signals. Simulation results show acceptable performance regarding LMS and variable step LMS, thus establishing the efficacy of the proposed method.Keywords: Kalman filter, Motion artifact, PPG, Photoplethysmography.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 42611581 Design of SiC Capacitive Pressure Sensor with LC-Based Oscillator Readout Circuit
Authors: Azza M. Anis, M. M. Abutaleb, Hani F. Ragai, M. I. Eladawy
Abstract:
This paper presents the characterization and design of a capacitive pressure sensor with LC-based 0.35 µm CMOS readout circuit. SPICE is employed to evaluate the characteristics of the readout circuit and COMSOL multiphysics structural analysis is used to simulate the behavior of the pressure sensor. The readout circuit converts the capacitance variation of the pressure sensor into the frequency output. Simulation results show that the proposed pressure sensor has output frequency from 2.50 to 2.28 GHz in a pressure range from 0.1 to 2 MPa almost linearly. The sensitivity of the frequency shift with respect to the applied pressure load is 0.11 GHz/MPa.
Keywords: CMOS LC-based oscillator, micro pressure sensor, silicon carbide
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 16691580 Blood Elements Activation in Hemodialysis – Animal Model Studies
Authors: Karolina Grzeszczuk-Kuć, Jolanta Bujok, Tomasz Walski, Małgorzata Komorowska
Abstract:
Haemodialysis (HD) is a procedure saving patient lives around the world, unfortunately it brings numerous complications. Oxidative stress is one of the major factors which lead to erythrocytes destruction during extracorporeal circulation. Repeated HD procedures destroy blood elements and the organism is not able to keep up with their production. 30 HD procedures on healthy sheep were performed to evaluate effects of such treatment. Oxidative stress study was performed together with an analysis of basic blood parameters and empirical assessment of dialyzer condition after the procedure. A reversible decline in absolute leukocyte count, during first 30 min of HD, was observed. Blood clots were formed in the area of the blood inlet and outlet of the dialyzer. Our results are consistent with outcomes presented throughout the literature specifically with respect to the effects observed in humans and will provide a basis to evaluate methods for blood protection during haemodialysis.
Keywords: Animal model, blood components, haemodialysis, leukocytes, oxidative stress, sheep.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 23461579 Ultrasensitive Hepatitis B Virus Detection in Blood Using Nano-Porous Silicon Oxide: Towards POC Diagnostics
Authors: N. Das, N. Samanta, L. Pandey, C. Roy Chaudhuri
Abstract:
Early diagnosis of infection like Hep-B virus in blood is important for low cost medical treatment. For this purpose, it is desirable to develop a point of care device which should be able to detect trace quantities of the target molecule in blood. In this paper, we report a nanoporous silicon oxide sensor which is capable of detecting down to 1fM concentration of Hep-B surface antigen in blood without the requirement of any centrifuge or pre-concentration. This has been made possible by the presence of resonant peak in the sensitivity characteristics. This peak is observed to be dependent only on the concentration of the specific antigen and not on the interfering species in blood serum. The occurrence of opposite impedance change within the pores and at the bottom of the pore is responsible for this effect. An electronic interface has also been designed to provide a display of the virus concentration.
Keywords: Impedance spectroscopy, Ultrasensitive detection in blood, Peak frequency, Electronic interface.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 26931578 The Association between C-Reactive Protein and Hypertension of Different United States Participants Categorized by Ethnicity: Applying the National Health and Nutrition Examination Survey from 1999-2010
Authors: Ghada Abo-Zaid
Abstract:
Objectives: The main objective of this study was to examine the association between the elevated level of C-reactive protein (CRP) and incidence of hypertension before and after adjustments for age, BMI, gender, SES, smoking, diabetes, cholesterol LDL and cholesterol HDL, and to determine whether the association differs by race. Method: Cross sectional data for participants from aged 17 years to 74 years, included in The National Health and Nutrition Examination Survey (NHANES) from 1999 to 2010 were analyzed. The CRP level was classified into three categories (> 3 mg/L, between 1 mg/L and 3 mg/L, and < 3 mg/L). Blood pressure categorization was done using JNC 7 indicator. Hypertension is defined as either systolic blood pressure (SBP) of 140 mmHg or more and diastolic blood pressure (DBP) of 90 mmHg or more, otherwise a self-reported prior diagnosis by a physician. Pre-hypertension was defined as 139 ≥ SBP > 120 or 89 ≥ DBP >80. Multinominal regression model was undertaken to measure the association between CRP level and hypertension. Results: In univariable models, CRP concentrations > 3 mg/L were associated with a 73% greater risk of incident hypertension compared with CRP concentrations < 1 mg/L (Hypertension: odds ratio [OR] = 1.73; 95% confidence interval [CI], 1.50-1.99). Ethnic comparisons showed that American Mexicans had the highest risk of incident hypertension (OR = 2.39; 95% CI, 2.21-2.58). This risk was statistically insignificant after controlling by other variables (Hypertension: OR = 0.75; 95% CI, 0.52-1.08), or categorized by race [American Mexican: OR= 1.58; 95% CI, 0.58-4.26, Other Hispanic: OR = 0.87; 95% CI, 0.19-4.42, Non-Hispanic white: OR = 0.90; 95% CI, 0.50-1.59, Non-Hispanic Black: OR = 0.44; 95% CI, 0.22-0.87. The same results were found for pre-hypertension, and the Non-Hispanic black segment showed the highest significant risk for Pre-Hypertension (OR = 1.60; 95% CI, 1.26-2.03). When CRP concentrations were between 1.0 and 3.0 mg/L in unadjusted models, prehypertension was associated with higher likelihood of elevated CRP (OR = 1.37; 95% CI, 1.15-1.62). The same relationship was maintained in Non-Hispanic white, Non-Hispanic black, and other race (Non-Hispanic white: OR = 1.24; 95% CI, 1.03-1.48, Non-Hispanic black: OR = 1.60; 95% CI, 1.27-2.03, other race: OR = 2.50; 95% CI, 1.32-4.74) while the association was insignificant with American Mexican and other Hispanic. In the adjusted model, the relationship between CRP and prehypertension were no longer available. Contrary, hypertension was not independently associated with elevated CRP, and the results were the same after being grouped by race or adjustments for the possible confounder variables. The same results were obtained when SBP or DBP were on a continuous measure. Conclusions: This study confirmed the existence of an association between hypertension, prehypertension and elevated level of CRP, however this association was no longer available after adjusting by other variables. Ethic group differences were statistically significant at the univariable models, while it disappeared after controlling by other variables.Keywords: CRP, hypertension, ethnicity, NHANES, blood pressure.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 13601577 Effect of a Multiple Stenosis on Blood Flow through a Tube
Authors: Vipin Kumar Verma, Praveen Saraswat
Abstract:
The development of double stenosis in an artery can have serious consequences and can disrupt the normal functioning of the circulatory system. It has been realized that various hydrodynamics effects (i.e. wall shear, pressure distribution etc.) play important role in the development of this disease. Generally in the literature, the cross-section of the artery is assumed to be uniform with a single stenosis. However, in real situation the multiple stenosis develops in series along the length of artery whose cross-section varies slowly. Therefore, the flow of blood is laminar through a small diameter artery with axisymmetric identical double stenosis in series.
Keywords: Wall shear, multiple stenosis, artery.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 19001576 A Numerical Model for Simulation of Blood Flow in Vascular Networks
Authors: Houman Tamaddon, Mehrdad Behnia, Masud Behnia
Abstract:
An accurate study of blood flow is associated with an accurate vascular pattern and geometrical properties of the organ of interest. Due to the complexity of vascular networks and poor accessibility in vivo, it is challenging to reconstruct the entire vasculature of any organ experimentally. The objective of this study is to introduce an innovative approach for the reconstruction of a full vascular tree from available morphometric data. Our method consists of implementing morphometric data on those parts of the vascular tree that are smaller than the resolution of medical imaging methods. This technique reconstructs the entire arterial tree down to the capillaries. Vessels greater than 2 mm are obtained from direct volume and surface analysis using contrast enhanced computed tomography (CT). Vessels smaller than 2mm are reconstructed from available morphometric and distensibility data and rearranged by applying Murray’s Laws. Implementation of morphometric data to reconstruct the branching pattern and applying Murray’s Laws to every vessel bifurcation simultaneously, lead to an accurate vascular tree reconstruction. The reconstruction algorithm generates full arterial tree topography down to the first capillary bifurcation. Geometry of each order of the vascular tree is generated separately to minimize the construction and simulation time. The node-to-node connectivity along with the diameter and length of every vessel segment is established and order numbers, according to the diameter-defined Strahler system, are assigned. During the simulation, we used the averaged flow rate for each order to predict the pressure drop and once the pressure drop is predicted, the flow rate is corrected to match the computed pressure drop for each vessel. The final results for 3 cardiac cycles is presented and compared to the clinical data.
Keywords: Blood flow, Morphometric data, Vascular tree, Strahler ordering system.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 21011575 Dopamine and Serotonin Levels in Blood Samples of Jordanian Children Who Stutter
Authors: Mazin Alqhazo, Ayat Bani Rashaid
Abstract:
This study examines the levels of dopamine and serotonin in blood samples of children who stutter compared with normal fluent speakers. Blood specimens from 50 children who stutter (6 females, 44 males) and 50 normal children matched age and gender were collected for the purpose of the current study. The concentrations of dopamine and serotonin were measured using the 1100 series high-performance liquid chromatography coupled with ultraviolet detector instrument (HPLC-UV). It was revealed that dopamine level in the blood samples of stuttering group and fluent group was not significant (P = 0.769), whereas the level of serotonin was significantly higher in the blood samples of stuttering group than the blood samples of fluent normal group (P = 0.015). It is concluded that serotonin blockers could be used in future studies to evaluate its role as a medication for the treatment of stuttering.
Keywords: Dopamine, serotonin, stuttering, fluent.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 8701574 The Applications of Four Fingers Theory: The Proof of 66 Acupoints under the Human Elbow and Knee
Authors: Chih-I. Tsai, Yu-Chien. Lin
Abstract:
Through experiences of clinical practices, it is discovered that locations on the body at a level of four fingerbreadth above and below the joints are the points at which muscles connect to tendons, and since the muscles and tendons possess opposite characteristics, muscles are full of blood but lack qi, while tendons are full of qi but lack blood, these points on our body become easily blocked. It is proposed that through doing acupuncture or creating localized pressure to the areas four fingerbreadths above and below our joints, with an elastic bandage, we could help the energy, also known as qi, to flow smoothly in our body and further improve our health. Based on the Four Fingers Theory, we understand that human height is 22 four fingerbreadths. In addition, qi and blood travel through 24 meridians, 50 times each day, and they flow through 6 cun with every human breath. We can also understand the average number of human heartbeats is 75 times per minute. And the function of qi-blood circulation system in Traditional Chinese Medicine is the same as the blood circulation in Western Medical Science. Informed by Four Fingers Theory, this study further examined its applications in acupuncture practices. The research question is how Four Fingers Theory proves what has been mentioned in Nei Jing that there are 66 acupoints under a human’s elbow and knee. In responding to the research question, there are 66 acupoints under a human’s elbow and knee. Four Fingers Theory facilitated the creation of the acupuncture naming and teaching system. It is expected to serve as an approachable and effective way to deliver knowledge of acupuncture to the public worldwide.
Keywords: Four Fingers theory, Meridians circulation, 66 Acupoints under a human’s elbow and knee, acupuncture.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 15961573 Metal Berthelot Tubes with Windows for Observing Cavitation under Static Negative Pressure
Authors: K. Hiro, Y. Imai, T. Sasayama
Abstract:
Cavitation under static negative pressure is not revealed well. The Berthelot method to generate such negative pressure can be a means to study cavitation inception. In this study, metal Berthelot tubes built in observation windows are newly developed and are checked whether high static negative pressure is generated or not. Negative pressure in the tube with a pair of a corundum plate and an aluminum gasket increased with temperature cycles. The trend was similar to that as reported before.
Keywords: Berthelot method, negative pressure, cavitation.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 10571572 The Effect of Glucogenic and Lipogenic Diets on Blood Metabolites of Baloochi Sheep
Authors: Alireza Vakili, Ali Mortezaee, Mohsen Danesh Mesgaran
Abstract:
The aim of present study was to assess the effect of glucogenic (G) and lipogenic (L) diets on blood metabolites in Baloochi lambs. Three rumen cannulated Baloochi sheep were used as a 3×3 Latin square design with 3 periods (28 days). Experimental diets were a glucogenic, a lipogenic and a mixture of G and L diets (50:50). The animals were fed diets consisted of 50% chopped alfalfa hay and 50% concentrate. Diets were fed once daily ad libitum. Blood samples were taken from jugular vein before the feeding, 2, 4 and 6 hour post feeding at day 27. Results indicated that β- hydroxybutyrate (BHBA), glucose, insulin and aspartate aminotransferase (AST) were not affected by treatments (P > 0.05). However, lipogenic diet increased significantly activity of Alanine aminotransferase (ALT) and concentration of non-esterified fatty acid (NEFA) in blood plasma (P < 0.05)Keywords: glucogenic, lipogenic, blood metabolites
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 22501571 Effects of Dry Period Length on, Milk Production and Composition, Blood Metabolites and Complete Blood Count in Subsequent Lactation of Holstein Dairy Cows
Authors: Akbar Soleimani, Alireza Heravi Moussavi, Mohsen Danesh Mesgaran, Abolqasem Golian
Abstract:
Twenty - nine Holstein cows were used to evaluate the effects of different dry period (DP) lengths on milk yield and composition, some blood metabolites, and complete blood count (CBC). Cows were assigned to one of 2 treatments: 1) 60-d dry period, 2) 35-d DP. Milk yield, from calving to 60 days, was not different for cows on the treatments (p =0.130). Cows in the 35-d DP produced more milk protein and SNF compare with cows in treatment 1 (p ≤ 0.05). Serum glucose, non-esterified fatty acids (NEFA), beta hydroxyl butyrate acid (BHBA), blood urea nitrogen (BUN), urea, and glutamic oxaloacetic transaminase (GOT) were all similar among the treatments. Body condition score (BCS), body weight (BW), complete blood count (CBC) and health problems were similar between the treatments. The results of this study demonstrated we can reduce the dry period length to 35 days with no problems.
Keywords: complete blood count, dairy cows, dry period, milk yield
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 19361570 Blood Glucose Level Measurement from Breath Analysis
Authors: Tayyab Hassan, Talha Rehman, Qasim Abdul Aziz, Ahmad Salman
Abstract:
The constant monitoring of blood glucose level is necessary for maintaining health of patients and to alert medical specialists to take preemptive measures before the onset of any complication as a result of diabetes. The current clinical monitoring of blood glucose uses invasive methods repeatedly which are uncomfortable and may result in infections in diabetic patients. Several attempts have been made to develop non-invasive techniques for blood glucose measurement. In this regard, the existing methods are not reliable and are less accurate. Other approaches claiming high accuracy have not been tested on extended dataset, and thus, results are not statistically significant. It is a well-known fact that acetone concentration in breath has a direct relation with blood glucose level. In this paper, we have developed the first of its kind, reliable and high accuracy breath analyzer for non-invasive blood glucose measurement. The acetone concentration in breath was measured using MQ 138 sensor in the samples collected from local hospitals in Pakistan involving one hundred patients. The blood glucose levels of these patients are determined using conventional invasive clinical method. We propose a linear regression classifier that is trained to map breath acetone level to the collected blood glucose level achieving high accuracy.
Keywords: Blood glucose level, breath acetone concentration, diabetes, linear regression.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 15511569 Design of Saddle Support for Horizontal Pressure Vessel
Authors: Vinod Kumar, Navin Kumar, Surjit Angra, Prince Sharma
Abstract:
This paper presents the design analysis of saddle support of a horizontal pressure vessel. Since saddle have the vital role to support the pressure vessel and to maintain its stability, it should be designed in such a way that it can afford the vessel load and internal pressure of the vessel due to liquid contained in the vessel. A model of horizontal pressure vessel and saddle support is created in ANSYS. Stresses are calculated using mathematical approach and ANSYS software. The analysis reveals the zone of high localized stress at the junction part of the pressure vessel and saddle support due to operating conditions. The results obtained by both the methods are compared with allowable stress value for safe designing.
Keywords: ANSYS, Pressure Vessel, Saddle, Support.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 261431568 A Novel Method for Blood Glucose Measurement by Noninvasive Technique Using Laser
Authors: V.Ashok, A.Nirmalkumar, N.Jeyashanthi
Abstract:
A method and apparatus for noninvasive measurement of blood glucose concentration based on transilluminated laser beam via the Index Finger has been reported in this paper. This method depends on atomic gas (He-Ne) laser operating at 632.8nm wavelength. During measurement, the index finger is inserted into the glucose sensing unit, the transilluminated optical signal is converted into an electrical signal, compared with the reference electrical signal, and the obtained difference signal is processed by signal processing unit which presents the results in the form of blood glucose concentration. This method would enable the monitoring blood glucose level of the diabetic patient continuously, safely and noninvasively.Keywords: Anisotropy factor, Blood glucose, Diabetes Mellitus, Noninvasive method, Photo detectors.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 32951567 The Effect of Angle of Attack on Pressure Drag from a Cam Shaped Tube
Authors: Arash Mir Abdolah Lavasani
Abstract:
The pressure drag from a cam shaped tube in cross flows have been investigated experimentally using pressure distribution measurement. The range of angle of attack and Reynolds number based on an equivalent circular tube are within 0≤α≤360° and 2×104< Reeq < 3.4 ×104, respectively. It is found that the pressure drag coefficient is at its highest at α=90° and 270° over the whole range of Reynolds number. Results show that the pressure drag coefficient of the cam shaped tube is lower than that of circular tube with the same surface area for more of the angles of attack. Furthermore, effects of the diameter ratio and finite length of the cam shaped tube upon the pressure drag coefficient are discussed.
Keywords: Pressure Drag, Cam Shaped, Experimental.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 23801566 Effect of L/D Ratio on the Performance of a Four-Lobe Pressure Dam Bearing
Authors: G. Bhushan, S. S. Rattan, N. P. Mehta
Abstract:
A four-lobe pressure dam bearing which is produced by cutting two pressure dams on the upper two lobes and two relief-tracks on the lower two lobes of an ordinary four-lobe bearing is found to be more stable than a conventional four-lobe bearing. In this paper a four-lobe pressure dam bearing supporting rigid and flexible rotors is analytically investigated to determine its performance when L/D ratio is varied in the range 0.75 to 1.5. The static and dynamic characteristics are studied at various L/D ratios. The results show that the stability of a four-lobe pressure dam bearing increases with decrease in L/D ratios both for rigid as well as flexible rotors.Keywords: Four-lobe pressure dam bearing, finite-elementmethod, L/D ratio.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 26421565 Perception of Predictive Confounders for the Prevalence of Hypertension among Iraqi Population: A Pilot Study
Authors: Zahraa Albasry, Hadeel D. Najim, Anmar Al-Taie
Abstract:
Background: Hypertension is considered as one of the most important causes of cardiovascular complications and one of the leading causes of worldwide mortality. Identifying the potential risk factors associated with this medical health problem plays an important role in minimizing its incidence and related complications. The objective of this study is to explore the prevalence of receptor sensitivity regarding assess and understand the perception of specific predictive confounding factors on the prevalence of hypertension (HT) among a sample of Iraqi population in Baghdad, Iraq. Materials and Methods: A randomized cross sectional study was carried out on 100 adult subjects during their visit to the outpatient clinic at a certain sector of Baghdad Province, Iraq. Demographic, clinical and health records alongside specific screening and laboratory tests of the participants were collected and analyzed to detect the potential of confounding factors on the prevalence of HT. Results: 63% of the study participants suffered from HT, most of them were female patients (P < 0.005). Patients aged between 41-50 years old significantly suffered from HT than other age groups (63.5%, P < 0.001). 88.9% of the participants were obese (P < 0.001) and 47.6% had diabetes with HT. Positive family history and sedentary lifestyle were significantly higher among all hypertensive groups (P < 0.05). High salt and fatty food intake was significantly found among patients suffered from isolated systolic hypertension (ISHT) (P < 0.05). A significant positive correlation between packed cell volume (PCV) and systolic blood pressure (SBP) (r = 0.353, P = 0.048) found among normotensive participants. Among hypertensive patients, a positive significant correlation found between triglycerides (TG) and both SBP (r = 0.484, P = 0.031) and diastolic blood pressure (DBP) (r = 0.463, P = 0.040), while low density lipoprotein-cholesterol (LDL-c) showed a positive significant correlation with DBP (r = 0.443, P = 0.021). Conclusion: The prevalence of HT among Iraqi populations is of major concern. Further consideration is required to detect the impact of potential risk factors and to minimize blood pressure (BP) elevation and reduce the risk of other cardiovascular complications later in life.Keywords: Correlation, hypertension, Iraq, risk factors.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 9241564 Methane Production from Biomedical Waste (Blood)
Authors: Fatima M. Kabbashi, Abdalla M. Abdalla, Hussam K. Hamad, Elias S. Hassan
Abstract:
This study investigates the production of renewable energy (biogas) from biomedical hazard waste (blood) and eco-friendly disposal. Biogas is produced by the bacterial anaerobic digestion of biomaterial (blood). During digestion process bacterial feeding result in breaking down chemical bonds of the biomaterial and changing its features, by the end of the digestion (biogas production) the remains become manure as known. That has led to the economic and eco-friendly disposal of hazard biomedical waste (blood). The samples (Whole blood, Red blood cells 'RBCs', Blood platelet and Fresh Frozen Plasma ‘FFP’) are collected and measured in terms of carbon to nitrogen C/N ratio and total solid, then filled in connected flasks (three flasks) using water displacement method. The results of trails showed that the platelet and FFP failed to produce flammable gas, but via a gas analyzer, it showed the presence of the following gases: CO, HC, CO₂, and NOX. Otherwise, the blood and RBCs produced flammable gases: Methane-nitrous CH₃NO (99.45%), which has a blue color flame and carbon dioxide CO₂ (0.55%), which has red/yellow color flame. Methane-nitrous is sometimes used as fuel for rockets, some aircraft and racing cars.
Keywords: Renewable energy, biogas, biomedical waste, blood, anaerobic digestion, eco-friendly disposal.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 12171563 Modeling the Vapor Pressure of Biodiesel Fuels
Authors: O. Castellanos Díaz, F. Schoeggl, H. W. Yarranton, M. A. Satyro, T. M. Lovestead, T. J. Bruno
Abstract:
The composition, vapour pressure, and heat capacity of nine biodiesel fuels from different sources were measured. The vapour pressure of the biodiesel fuels is modeled assuming an ideal liquid phase of the fatty acid methyl esters constituting the fuel. New methodologies to calculate the vapour pressure and ideal gas and liquid heat capacities of the biodiesel fuel constituents are proposed. Two alternative optimization scenarios are evaluated: 1) vapour pressure only; 2) vapour pressure constrained with liquid heat capacity. Without physical constraints, significant errors in liquid heat capacity predictions were found whereas the constrained correlation accurately fit both vapour pressure and liquid heat capacity.Keywords: Biodiesel fuels, Fatty acid methyl ester, Heat capacity, Modeling, Vapour pressure
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 60101562 Measurement of Reverse Flow Generated at Cold Exit of Vortex Tube
Authors: Mohd Hazwan bin Yusof, Hiroshi Katanoda
Abstract:
In order to clarify the structure of the cold flow discharged from the vortex tube (VT), the pressure of the cold flow was measured, and a simple flow visualization technique using a 0.75mm-diameter needle and an oily paint is made to study the reverse flow at the cold exit. It is clear that a negative pressure and positive pressure region exist at a certain pressure and cold fraction area, and that a reverse flow is observed in the negative pressure region.
Keywords: Flow visualization, Pressure measurement, Reverse flow, Vortex tube.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 19271561 Biosensor Measurement of Urea Coonncentration in Human Blood Serum
Authors: O. L. Kukla, S. V. Marchenko, O. A. Zinchenko, O. S. Pavluchenko, O. M. KKuukla, S. V. Dzyadevych, O. P. Soldatkin
Abstract:
An application of the highly biosensor based on pH-sensitive field immobilized urease for urea analysis was demo The main analytical characteristics of the bios determined; the conditions of urea measureme blood were optimized. A conceptual possibility biosensor for detection of urea concentratio patients suffering from renal insufficiency was sensitive and selective effect transistor and monstrated in this work. iosensor developed were ment in real samples of ility of application of the tion in blood serum of as shown.
Keywords: Biosensor, blood serum, pH transistor, urea, urease, field-effect
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1944