Search results for: Roof top rain water harvesting.
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2584

Search results for: Roof top rain water harvesting.

2164 Effect of Crude Oil on Soil-Water Characteristic Curve of Clayey Soil

Authors: Seyed Abolhasan Naeini, Seyed Mohammad Reza Hosseini

Abstract:

The measured soil suction values when related to water content is called suction-water content relationship (SWR) or soil-water characteristic curve (SWCC) and forms the basis of unsaturated soil behavior assessment. The SWCC can be measured or predicted based on soil index properties such as grain-size distribution and plasticity index. In this paper, the SWCC of clean and contaminated clayey soil classified as clay with low plasticity (CL) are presented. Laboratory studies were conducted on virgin (disturbed-uncontaminated soil collected from vicinity of Tehran oil refinery) soil and soil samples simulated to varying degrees of contamination with crude oil (i.e., 3, 6, and 9% by dry weight of soil) to compare the results before and after contamination. Laboratory tests were conducted using a device which is capable of measuring volume change and pore pressures. The soil matric suction at the ends of samples controlled by using the axis translation technique. The results show that contamination with crude oil facilitates the movement of water and reduces the soil suction.

Keywords: Axis translation technique, clayey soil, contamination, crude oil, soil-water characteristic curve.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1859
2163 Photocatalytic Degradation of Produced Water Hydrocarbon of an Oil Field by Using Ag-Doped TiO2 Nanoparticles

Authors: Hamed Bazrafshan, Saeideh Dabirnia, Zahra Alipour Tesieh, Samaneh Alavi, Bahram Dabir

Abstract:

In this study, the removal of pollutants of a real produced water sample from an oil reservoir (a light oil reservoir), using a photocatalytic degradation process in a cylindrical glass reactor, was investigated. Using TiO2 and Ag-TiO2 in slurry form, the photocatalytic degradation was studied by measuring the Chemical Oxygen Demand (COD) parameter, qualitative analysis, and GC-MS. At first, optimization of the parameters on photocatalytic degradation of hydrocarbon pollutants in real produced water, using TiO2 nanoparticles as photocatalysts under UV light, was carried out applying response surface methodology. The results of the design of the experiment showed that the optimum conditions were at a catalyst concentration of 1.14 g/lit and pH of 2.67, and the percentage of COD removal was 72.65%.

Keywords: Photocatalyst, Ag-doped, TiO2, produced water, nanoparticles.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 517
2162 Allelopathic Effects of Sisymbrium irio L. and Descurainia sophia (L.) Schur on the Germination of Wheat (Triticum aestivum L.)

Authors: Sh. Edrisi, A. Farahbakhsh

Abstract:

An experiment was conducted under controlled conditions to study the effect of water extract of leaves, shoots and roots of either Sisymbrium irio L. =SISIR and/or Descurainia sophia (L.) Schur =DESSO on the germination and primary growth of wheat. A split-split plot experiment in CRD with three replications was used. The main plots were the type of weed: i.e. SISIR and DESSO and the sub-plots were type of organ: i.e. leaf, stem and root and, the sub-sub plots were concentration of the water extract of each organ of the weeds: i.e. 0, 2, 4 and 8 % w/v. The plant materials were cut in 2-3 cm pieces and then were ground in a blender. The crushed materials were weighed according to experimental protocol and the final volume was reached to 100 ml in distilled water in dark bottles. All bottles were put on a shaker for 24 hours. The solutions were filtered by muslin cloth. Whatman paper, 9 cm in diameter, were put in petri dishes and twenty seeds of wheat were put on it and 5 ml distilled water or water extract of weeds were added to each petri dish. All petri dishes were put in constant temperature of 15 0C incubator. The results showed that the SISIR water extract had a greater inhibitory effects on germination and primary growth of wheat than those of DESSO water extract. The water extracts of the leaves of both weeds had the greatest inhibitory effects on germination and primary growth of wheat, compared to those of stems and roots. Increasing the concentration of water extract of leaves, stems and roots of both weeds up to 8 % caused the greatest inhibitory effects to wheat and reduced the germination rate and primary growth of it linearly.

Keywords: Allelopathy, DESSO, SISIR, wheat

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1613
2161 Irrigation Water Quality Evaluation Based on Multivariate Statistical Analysis: A Case Study of Jiaokou Irrigation District

Authors: Panpan Xu, Qiying Zhang, Hui Qian

Abstract:

Groundwater is main source of water supply in the Guanzhong Basin, China. To investigate the quality of groundwater for agricultural purposes in Jiaokou Irrigation District located in the east of the Guanzhong Basin, 141 groundwater samples were collected for analysis of major ions (K+, Na+, Mg2+, Ca2+, SO42-, Cl-, HCO3-, and CO32-), pH, and total dissolved solids (TDS). Sodium percentage (Na%), residual sodium carbonate (RSC), magnesium hazard (MH), and potential salinity (PS) were applied for irrigation water quality assessment. In addition, multivariate statistical techniques were used to identify the underlying hydrogeochemical processes. Results show that the content of TDS mainly depends on Cl-, Na+, Mg2+, and SO42-, and the HCO3- content is generally high except for the eastern sand area. These are responsible for complex hydrogeochemical processes, such as dissolution of carbonate minerals (dolomite and calcite), gypsum, halite, and silicate minerals, the cation exchange, as well as evaporation and concentration. The average evaluation levels of Na%, RSC, MH, and PS for irrigation water quality are doubtful, good, unsuitable, and injurious to unsatisfactory, respectively. Therefore, it is necessary for decision makers to comprehensively consider the indicators and thus reasonably evaluate the irrigation water quality.

Keywords: Irrigation water quality, multivariate statistical analysis, groundwater, hydrogeochemical process.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 569
2160 Numerical Study of Vortex Formation inside a Stirred Tank

Authors: Divya Rajavathsavai, Akhilesh Khapre, Basudeb Munshi

Abstract:

The computational fluid dynamics (CFD) study of stirred tank with the air-water interface are carried out in the presence of different types of the impeller and with or without baffles. A multiple reference frame (MRF) approach with the volume of fluid (VOF) method is used to capture the air-water interface. The RANS (Reynolds Averaged Navier-Stokes) equations with k-ε turbulence model are solved to predict the flow behavior of water and air phase which are treated as a different phases. The predicted results have shown that the VOF method is able to capture the interface in the unbaffled tank. While, the VOF method is showing an unfeasible results in the baffled tank with high rotational impeller speed. For continuous stirred tank, the air-water interface is disturbed by the inflow and the level of water is also increased with time.

Keywords: Computational Fluid Dynamics, stirred tank, airwater interface, multiple reference frame, volume of fluid, Reynolds Averaged Navier-Stokes equations.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4368
2159 Conjunctive Surface Runoff and Groundwater Management in Salinity Soils

Authors: S. Chuenchooklin, T. Ichikawa, P. Mekpruksawong

Abstract:

This research was conducted in the Lower Namkam Irrigation Project situated in the Namkam River Basin in Thailand. Degradation of groundwater quality in some areas is caused by saline soil spots beneath ground surface. However, the tail regulated gate structure on the Namkam River, a lateral stream of the Mekong River. It is aimed for maintaining water level in the river at +137.5 to +138.5 m (MSL) and flow to the irrigation canals based on a gravity system since July 2009. It might leach some saline soil spots from underground to soil surface if lack of understanding of the conjunctive surface water and groundwater behaviors. This research has been conducted by continuously the observing of both shallow and deep groundwater level and quality from existing observation wells. The simulation of surface water was carried out using a hydrologic modeling system (HEC-HMS) to compute the ungauged side flow catchments as the lateral flows for the river system model (HEC-RAS). The constant water levels in the upstream of the operated gate caused a slight rising up of shallow groundwater level when compared to the water table. However, the groundwater levels in the confined aquifers remained less impacted than in the shallow aquifers but groundwater levels in late of wet season in some wells were higher than the phreatic surface. This causes salinization of the groundwater at the soil surface and might affect some crops. This research aims for the balance of water stage in the river and efficient groundwater utilization in this area.

Keywords: Surface water, groundwater observation, irrigation, water balance.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1834
2158 Artificial Neural Network Model for a Low Cost Failure Sensor: Performance Assessment in Pipeline Distribution

Authors: Asar Khan, Peter D. Widdop, Andrew J. Day, Aliaster S. Wood, Steve, R. Mounce, John Machell

Abstract:

This paper describes an automated event detection and location system for water distribution pipelines which is based upon low-cost sensor technology and signature analysis by an Artificial Neural Network (ANN). The development of a low cost failure sensor which measures the opacity or cloudiness of the local water flow has been designed, developed and validated, and an ANN based system is then described which uses time series data produced by sensors to construct an empirical model for time series prediction and classification of events. These two components have been installed, tested and verified in an experimental site in a UK water distribution system. Verification of the system has been achieved from a series of simulated burst trials which have provided real data sets. It is concluded that the system has potential in water distribution network management.

Keywords: Detection, leakage, neural networks, sensors, water distribution networks

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1745
2157 Chemical and Hydro-Geologic Analysis of Ikogosi Warm Spring Water in Nigeria

Authors: Akinola Ikudayisi, Folasade Adeyemo, Josiah Adeyemo

Abstract:

This study focuses on the hydro-geology and chemical constituents analysis of Ikogosi Warm Spring waters in South West Nigeria. Ikogosi warm spring is a global tourist attraction because it has both warm and cold spring sources. Water samples from the cold spring, warm spring and the meeting point were collected, analyzed and the result shows close similarity in temperature, hydrogen iron concentration (pH), alkalinity, hardness, Calcium, Magnesium, Sodium, Iron, total dissolved solid and heavy metals. The measured parameters in the water samples are within World Health Organisation standards for fresh water. The study of the geology of the warm spring reveals that the study area is underlain by a group of slightly migmatised to non-migmatised paraschists and meta-igneous rocks. Also, concentration levels of selected heavy metals, (Copper, Cadmium, Zinc, Arsenic and Cromium) were determined in the water (ppm) samples. Chromium had the highest concentration value of 1.52ppm (an average of 49.67%) and Cadmium had the lowest concentration with value of 0.15ppm (an average of 4.89%). Comparison of these results showed that, their mean levels are within the standard values obtained in Nigeria. It can be concluded that both warm and spring water are safe for drinking.

Keywords: Cold spring, Ikogosi, melting point, warm spring, water samples.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2305
2156 Influence of Silica Surface Hydrophilicity on Adsorbed Water and Isopropanol Studied by in-situ NMR

Authors: Hyung T. Kwak, Jun Gao, Yao An, Alfred Kleinhammes, Yue Wu

Abstract:

Surface wettability is a crucial factor in oil recovery. In oil industry, the rock wettability involves the interplay between water, oil, and solid surface. Therefore, studying the interplay between adsorptions of water and hydrocarbon molecules on solid surface would be very informative for understanding rock wettability. Here we use the in-situ Nuclear Magnetic Resonance (NMR) gas isotherm technique to study competitive adsorptions of water and isopropanol, an intermediate step from hydrocarbons. This in-situ NMR technique obtains information on thermodynamic properties such as the isotherm, molecular dynamics via spin relaxation measurements, and adsorption kinetics such as how fast the system can reach thermal equilibrium after changes of vapor pressures. Using surfaces of silica glass beads, which can be modified from hydrophilic to hydrophobic, we obtained information on the influence of surface hydrophilicity on the state of surface water via obtained thermodynamic and dynamic properties.

Keywords: Competitive adsorption, nuclear magnetic resonance, wettability.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 728
2155 Underwater Interaction of 1064 nm Laser Radiation with Metal Target

Authors: G. Toker, V. Bulatov, T. Kovalchuk, I. Schechter

Abstract:

Dynamics of laser radiation – metal target interaction in water at 1064 nm by applying Mach-Zehnder interference technique was studied. The mechanism of generating the well developed regime of evaporation of a metal surface and a spherical shock wave in water is proposed. Critical intensities of the NIR for the well developed evaporation of silver and gold targets were determined. Dynamics of shock waves was investigated for earlier (dozens) and later (hundreds) nanoseconds of time. Transparent expanding plasma-vapor-compressed water object was visualized and measured. The thickness of compressed layer of water and pressures behind the front of a shock wave for later time delays were obtained from the optical treatment of interferograms.

Keywords: laser, shock wave, metal target, underwater

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1669
2154 Detecting Cavitation in a Vertical Sea water Centrifugal Lift Pump Related to Iran Oil Industry Cooling Water Circulation System

Authors: Omid A. Zargar

Abstract:

Cavitation is one of the most well-known process faults that may occur in different industrial equipment especially centrifugal pumps. Cavitation also may happen in water pumps and turbines. Sometimes cavitation has been severe enough to wear holes in the impeller and damage the vanes to such a degree that the impeller becomes very ineffective. More commonly, the pump efficiency will decrease significantly during cavitation and continue to decrease as damage to the impeller increases. Typically, when cavitation occurs, an audible sound similar to ‘marbles’ or ‘crackling’ is reported to be emitted from the pump. In this paper, the most effective monitoring items and techniques in detecting cavitation discussed in details. Besides, some successful solutions for solving this problem for sea water vertical Centrifugal lift Pump discussed through a case history related to Iran oil industry. Furthermore, balance line modification, strainer choking and random resonance in sea water pumps discussed. In addition, a new Method for diagnosing mechanical conditions of sea water vertical Centrifugal lift Pumps introduced. This method involves disaggregating bus current by device into disaggregated currents having correspondences with operating currents in response to measured bus current. Moreover, some new patents and innovations in mechanical sea water pumping and cooling systems discussed in this paper.

Keywords: Cavitation, Vibration Analysis, Centrifugal Pump, Vertical Pump, Sea Water Pump, Balance Line, Strainer, Time Wave Form (TWF), Fast Fourier Transform (FFT)

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 4161
2153 Error Analysis of Nonconventional Electrical Moisture-meter under Simplified Conditions

Authors: Kamil Ďurana, Robert Černý

Abstract:

An electrical apparatus for measuring moisture content was developed by our laboratory and uses dependence of electrical properties on water content in studied material. Error analysis of the apparatus was run by measuring different volumes of water in a simplified specimen, i.e. hollow plexiglass block, in order to avoid as many side-effects as possible. Obtained data were processed using both basic and advanced statistics and results were compared with each other. The influence of water content on accuracy of measured data was studied as well as the influence of variation of apparatus' proper arrangement or factual methodics of its usage. The overall coefficient of variation was 4%. There was no trend found in results of error dependence on water content. Comparison with current surveys led to a conclusion, that the studied apparatus can be used for indirect measurement of water content in porous materials, with expectable error and under known conditions. Factual experiments with porous materials are not involved, but are currently under investigation.

Keywords: device, capacitance method, error analysis, moisture meter

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1389
2152 Removal of Phenylurea Herbicides from Waters by using Chemical Oxidation Treatments

Authors: F. Javier Benitez, Carolina Garcia, Juan Luis Acero, Francisco J. Real

Abstract:

Four phenylurea herbicides (isoproturon, chlortoluron, diuron and linuron) were dissolved in different water matrices in order to study their chemical degradation by using UV radiation, ozone and some advanced oxidation processes (UV/H2O2, O3/H2O2, Fenton reagent and the photo- Fenton system). The waters used were: ultra-pure water, a commercial mineral water, a groundwater and a surface water taken from a reservoir. Elimination levels were established for each herbicide and for several global quality parameters, and a kinetic study was performed in order to determine basic kinetic parameters of each reaction between the target phenylureas and these oxidizing systems.

Keywords: Phenylurea herbicides, UV radiation; Ozone, Fenton reagent, Hydroxyl radicals, Rate constants, Quantum yields

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1933
2151 50/50 Oil-Water Ratio Invert Emulsion Drilling Mud Using Vegetable Oil as Continuous Phase

Authors: P. C. Ihenacho, M. Burby, G. G. Nasr, G. C. Enyi

Abstract:

Formulation of a low oil-water ratio drilling mud with vegetable oil continuous phase without adversely affecting the mud rheology and stability has been a major challenge. A low oil-water ratio is beneficial in producing low fluid loss which is essential for wellbore stability. This study examined the possibility of 50/50 oil-water ratio invert emulsion drilling mud using a vegetable oil continuous phase. Jatropha oil was used as continuous phase. 12 ml of egg yolk which was separated from the albumen was added as the primary emulsifier additive. The rheological, stability and filtration properties were examined. The plastic viscosity and yield point were found to be 36cp and 17 Ib/100 ft2 respectively. The electrical stability at 48.9ºC was 353v and the 30 minutes fluid loss was 6ml. The results compared favourably with a similar formulation using 70/30 oil - water ratio giving plastic viscosity of 31cp, yield point of 17 Ib/100 ft2, electrical stability value of 480v and 12ml for the 30 minutes fluid loss. This study indicates that with a good mud composition using guided empiricism, 50/50 oil-water ratio invert emulsion drilling mud is feasible with a vegetable oil continuous phase. The choice of egg yolk as emulsifier additive is for compatibility with the vegetable oil and environmental concern. The high water content with no fluid loss additive will also minimise the cost of mud formulation.

Keywords: Environmental compatibility, low cost of mud formulation, low fluid loss, wellbore stability.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2960
2150 Germination of Barley as Affected by the Allelopathy of Sisymbrium irio L. and Descurainiasophia (L.) Schur

Authors: Sh. Edrisi, A. Farahbakhsh

Abstract:

An experiment was conducted under controlled conditions to study the effect of water extract of leaves, shoots and roots of either Sisymbrium irio L. =SISIR and or Descurainia sophia (L.) Schur =DESSO on the germination and primary growth of barley. A split-split plot experiment in CRD with three replications was used. The main plots were the type of weed: i.e. SISIR and DESSO and the sub-plots were type of organ: i.e. leaf, stem and root and, the sub-sub plots were concentration of the water extract of each organ of the weeds: i.e. 0, 2, 4 and 8 % w/v. The results showed that the SISIR water extracts had a greater inhibitory effects on the germination and primary growth of barley than those of DESSO water extracts. The water extracts of the leaves of both weeds had the greatest inhibitory effects on the germination and primary growth of barley, compared to those of stems and roots. Increasing the concentration of water extracts of leaves, stems and roots of both weeds up to 8 % caused the greatest inhibitory effects to barley and reduced the germination rate and primary growth of it linearly.

Keywords: Allelopathy, barley, DESSO, SISIR

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1528
2149 Study of Temperature Changes in Fars Province

Authors: A. Gandomkar, R. Dehghani

Abstract:

Climate change is a phenomenon has been based on the available evidence from a very long time ago and now its existence is very probable. The speed and nature of climate parameters changes at the middle of twentieth century has been different and its quickness more than the before and its trend changed to some extent comparing to the past. Climate change issue now regarded as not only one of the most common scientific topic but also a social political one, is not a new issue. Climate change is a complicated atmospheric oceanic phenomenon on a global scale and long-term. Precipitation pattern change, fast decrease of snowcovered resources and its rapid melting, increased evaporation, the occurrence of destroying floods, water shortage crisis, severe reduction at the rate of harvesting agricultural products and, so on are all the significant of climate change. To cope with this phenomenon, its consequences and events in which public instruction is the most important but it may be climate that no significant cant and effective action has been done so far. The present article is included a part of one surrey about climate change in Fars. The study area having annually mean temperature 14 and precipitation 320 mm .23 stations inside the basin with a common 37 year statistical period have been applied to the meteorology data (1974-2010). Man-kendal and change factor methods are two statistical methods, applying them, the trend of changes and the annual mean average temperature and the annual minimum mean temperature were studied by using them. Based on time series for each parameter, the annual mean average temperature and the mean of annual maximum temperature have a rising trend so that this trend is clearer to the mean of annual maximum temperature.

Keywords: Climate change, Coefficient Variation, Fars province, Man-Kendal method.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1915
2148 Bacteria Flora in the Gut and Respiratory Organs of Clarias gariepinus in Fresh and Brackish Water Habitats of Ondo State, South/West Nigeria

Authors: Nelson R. Osungbemiro, Rafiu O. Sanni, Rotimi F. Olaniyan, Abayomi O. Olajuyigbe

Abstract:

Bacteria flora of Clarias gariepinus collected from two natural habitats namely Owena River (freshwater) and Igbokoda lagoon (brackish water) were examined using standard microbiological procedures. Thirteen bacterial species were identified. The result indicated that from the identified bacteria isolated, Vibrio sp, Proteus sp. Shigella sp. and E. coli were present in both habitats (fresh and brackish waters). Others were habitat-selective such as Salmonella sp., Pseudomonas sp, Enterococcus sp, Staphylococcus sp. that were found only in freshwater habitat. While Branhamella sp, Streptococcus sp. and Micrococcus sp. were found in brackish water habitat. Bacteria load from Owena river (freshwater) was found to be the highest load recorded at 6.21 x 104cfu. T-test analysis also revealed that there was a marked significant difference between bacterial load in guts of sampled Clarias from fresh water and brackish water habitats.

Keywords: Bacteria flora, gut, Clarias gariepinus, Owena river

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2728
2147 Response of King Abdulla Canal Water to the Upgrade of As Samra WWTP

Authors: Abbas S. Al-Omari, Zain M. Al-Houri

Abstract:

The response of King Abdulla Canal (KAC) water to the upgrade of As Samra Wastewater Treatment Plant which discharges its effluent to the Zarqa River is investigated. Time series quality data that extends between October 2005 and December 2009 obtained by a state of the art telemetric monitoring system were analyzed for COD, EC, TP and TN at two monitoring stations located upstream and downstream of the confluence of the Zarqa River with KAC. The samples- means and the t-test showed that there has been significant improvement in the quality of the KAC water for COD, and TP. However, the improvement in the TN was found statistically insignificant, whereas the EC of the KAC was unaffected by the upgrade. Comparing the selected parameters with the standards and guidelines for using treated wastewater in irrigation showed that the KAC water has improved towards meeting the required standards and guidelines for treated wastewater reuse in irrigation.

Keywords: As Samra wastewater treatment plant, Telemetric monitoring system, Treated wastewater, Water quality monitoring, Zarqa River watershed.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1678
2146 Study of Aluminum, Copper and Molybdenum Pollution in Groundwater Sources Surrounding (Miduk) Shahr-E- Babak Copper Complex Tailings Dam

Authors: Maryam Kargar, Neamatolah Khorasani, Mahmoud Karami, Gholam-Reza Rafiee, Reza Naseh

Abstract:

Interpolated contour maps drawn for aluminum, copper and molybdenum in downstream monitoring boreholes of water dam in Miduk Copper Complex and the values of pH, redox potential (Eh) and distance from water dam indicate different trends of variation and behavior of these three elements in downward groundwater resources. As these maps exhibit, aluminum is dominant in the most alkaline (pH = 9-11) borehole (MB5) to water dam. The highest concentration of molybdenum is found in the nearest borehole (MB6) to water dam. Main concentration of copper is observed in the most oxidized borehole (MB3 with Eh=293.2mV). The spatial difference among sampling stations can be attributed to the existence of faults and diaclases in the geologic structure of Miduk region which causes the groundwater sampling sites to be impressed by different contamination sources (toe seepage and upper seepage water originated from different zones of tailings dump).

Keywords: Contour maps, Monitoring borehole, Toe seepage, Upper seepage.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2222
2145 Study of the Quality of Surface Water in the Upper Cheliff Basin

Authors: Touhari Fadhila, Mehaiguene Madjid, Meddi Mohamed

Abstract:

This work aims to assess the quality of water dams based on the monitoring of physical-chemical parameters by the National Agency of Water Resources (ANRH) for a period of 10 years (1999-2008). Quality sheets of surface water for the four dams in the region of upper Cheliff (Ghrib, Deurdeur, Harreza, and Ouled Mellouk) show a degradation of the quality (organic pollution expressed in COD and OM) over time. Indeed, the registered amount of COD often exceeds 50 mg/ l, and the OM exceeds 15 mg/l. This pollution is caused by discharges of wastewater and eutrophication. The waters of dams show a very high salinity (TDS = 2574 mg/l in 2008 for the waters of the dam Ghrib, standard = 1500 mg/l). The concentration of nitrogenous substances (NH4+, NO2-) in water is high in 2008 at Ouled Melloukdam. This pollution is caused by the oxidation of nitrogenous organic matter. On the other hand, we studied the relationship between the evolution of quality parameters and filling dams. We observed a decrease in the salinity and COD following an improvement of the filling state of dams, this resides in the dilution water through the contribution of rainwater. While increased levels of nitrates and phosphorus in the waters of four dams studied during the rainy season is compared to the dry period, this increase may be due to leaching from fertilizers used in agricultural soils situated in watersheds.

Keywords: Surface water quality, pollution, physical-chemical parameters, upper Cheliff basin.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 910
2144 Assessment of Nickel Concentration in Surface and Ground Water of the Kowsar Dam Basin

Authors: Fardin Boustani, M Hojati , S Ebrahimzadeh

Abstract:

The Kowsar dam supply water for different usages such as drinking, industrial, agricultural and aquaculture farms usages and located next to the city of Dehdashat in Kohgiluye and Boyerahmad province in southern Iran. There are some towns and villages on the Kowsar dam watersheds, which Dehdasht and Choram are the most important and populated cities in this area. The study was undertaken to assess the status of water quality in the urban areas of the Kowsar dam. A total of 28 water samples were collected from 6 stations on surface water and 1 station from groundwater on the watershed of the Kowsar dam. All the samples were analyzed for Ni concentration using standard procedures. The results were compared with other national and international standards. Among the analyzed samples, as the maximum value of Nickel (0.01 mg/L) was observed on the station 2 at the autumn 2010, all the samples analyzed were within the maximum admissible limits by the United States Environmental Protection Agency, EU, WHO and the Iranian. In general results of the present study have shown that a Ni mean value of station No. 2 with 0.006 mg/L is higher than the other stations. Ni level of all samples and stations have had normal values and this is an indication of pollution potential and hazards because of human activity and waste water of towns in the areas, which can effect on human health implications in future. This research, therefore, recommends the government and other responsible authorities to take suitable improving measures in the Kowsar dam watersheds.

Keywords: Kowsar dam, Drinking water quality, Nickel, Maximum admissible limit, World health organization

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1990
2143 Can Smart Meters Create Smart Behaviour?

Authors: Candice Moy, Damien Guirco, Thomas Boyle

Abstract:

Intelligent technologies are increasingly facilitating sustainable water management strategies in Australia. While this innovation can present clear cost benefits to utilities through immediate leak detection and deference of capital costs, the impact of this technology on households is less distinct. By offering real-time engagement and detailed end-use consumption breakdowns, there is significant potential for demand reduction as a behavioural response to increased information. Despite this potential, passive implementation without well-planned residential engagement strategies is likely to result in a lost opportunity. This paper begins this research process by exploring the effect of smart water meters through the lens of three behaviour change theories. The Theory of Planned Behaviour (TPB), Belief Revision theory (BR) and Practice Theory emphasise different variables that can potentially influence and predict household water engagements. In acknowledging the strengths of each theory, the nuances and complexity of household water engagement can be recognised which can contribute to effective planning for residential smart meter engagement strategies.

Keywords: Behaviour, information, household, smart meters, water.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1865
2142 Effect of Greywater Irrigation on Air-Water Interfacial area in Porous Medium

Authors: A. H. M. Faisal Anwar

Abstract:

In this study, the effect of greywater irrigation on airwater interfacial area is investigated. Several soil column experiments were conducted for different greywater irrigation to develop the pressure-saturation curves. Surface tension was measured for different greywater concentration and fitted for Gibbs adsorption equation. Pressure-saturation curves show that the reduction of capillary rise stops when it reaches its critical micelle concentration (CMC). A simple theory is derived from pressure-saturation curves for calculating air-water interfacial area in porous medium during greywater irrigation by introducing a term 'hydraulic radius' for the pores. This term diminishes any effect of pore shapes on the air-water interfacial area. The air-water interfacial area was calculated using the pressure-saturation curves and found that it decreases with increasing moisture content. But no significant effect was observed on air-water interfacial area for different greywater irrigation. A maximum of 10% variation in interfacial area was observed at the residual saturation zone.

Keywords: Greywater, Irrigation, Interfacial area, Surface tension, Porous medium.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1703
2141 Numerical Simulation of the Dynamic Behavior of a LaNi5 Water Pumping System

Authors: Miled Amel, Ben Maad Hatem, Askri Faouzi, Ben Nasrallah Sassi

Abstract:

Metal hydride water pumping system uses hydrogen as working fluid to pump water for low head and high discharge. The principal operation of this pump is based on the desorption of hydrogen at high pressure and its absorption at low pressure by a metal hydride. This work is devoted to study a concept of the dynamic behavior of a metal hydride pump using unsteady model and LaNi5 as hydriding alloy. This study shows that with MHP, it is possible to pump 340l/kg-cycle of water in 15 000s using 1 Kg of LaNi5 at a desorption temperature of 360 K, a pumping head equal to 5 m and a desorption gear ratio equal to 33. This study reveals also that the error given by the steady model, using LaNi5 is about 2%.A dimensional mathematical model and the governing equations of the pump were presented to predict the coupled heat and mass transfer within the MHP. Then, a numerical simulation is carried out to present the time evolution of the specific water discharge and to test the effect of different parameters (desorption temperature, absorption temperature, desorption gear ratio) on the performance of the water pumping system (specific water discharge, pumping efficiency and pumping time). In addition, a comparison between results obtained with steady and unsteady model is performed with different hydride mass. Finally, a geometric configuration of the reactor is simulated to optimize the pumping time.

Keywords: Dynamic behavior, unsteady model, LaNi5, performance of the water pumping system.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 771
2140 Breakdown of LDPE Film under Heavy Water Absorption

Authors: Eka PW, T. Okazaki, Y. Murakami, N., Hozumi, M. Nagao

Abstract:

The breakdown strength characteristic of Low Density Polyethylene films (LDPE) under DC voltage application and the effect of water absorption have been studied. Mainly, our experiment was investigated under two conditions; dry and heavy water absorption. Under DC ramp voltage, the result found that the breakdown strength under heavy water absorption has a lower value than dry condition. In order to clarify the effect, the temperature rise of film was observed using non contact thermograph until the occurrence of the electrical breakdown and the conduction current of the sample was also measured in correlation with the thermograph measurement. From the observations, it was shown that under the heavy water absorption, the hot spot in the samples appeared at lower voltage. At the same voltage the temperature of the hot spot and conduction current was higher than that under the dry condition. The measurement result has a good correlation between the existence of a critical field for conduction current and thermograph observation. In case of the heavy water absorption, the occurrence of the threshold field was earlier than the dry condition as result lead to higher of conduction current and the temperature rise appears after threshold field was significantly increased in increasing of field. The higher temperature rise was caused by the higher current conduction as the result the insulation leads to breakdown to the lower field application.

Keywords: Low density polyethylene, heavy water absorption, conduction current, temperature rise.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1880
2139 Mathematical Modeling of the Influence of Hydrothermal Processes in the Water Reservoir

Authors: Alibek Issakhov

Abstract:

In this paper presents the mathematical model of hydrothermal processes in thermal power plant with different wind direction scenarios in the water reservoir, which is solved by the Navier - Stokes and temperature equations for an incompressible fluid in a stratified medium. Numerical algorithm based on the method of splitting by physical parameters. Three dimensional Poisson equation is solved with Fourier method by combination of tridiagonal matrix method (Thomas algorithm).

Keywords: thermal power plant, hydrothermal process, large eddy simulation, water reservoir

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1644
2138 The Gasification of Fructose in Supercritical Water

Authors: Shyh-Ming Chern, H. Y. Cheng

Abstract:

Biomass is renewable and sustainable. As an energy source, it will not release extra carbon dioxide into the atmosphere. Hence, tremendous efforts have been made to develop technologies capable of transforming biomass into suitable forms of bio-fuel. One of the viable technologies is gasifying biomass in supercritical water (SCW), a green medium for reactions. While previous studies overwhelmingly selected glucose as a model compound for biomass, the present study adopted fructose for the sake of comparison. The gasification of fructose in SCW was investigated experimentally to evaluate the applicability of supercritical water processes to biomass gasification. Experiments were conducted with an autoclave reactor. Gaseous product mainly consists of H2, CO, CO2, CH4 and C2H6. The effect of two major operating parameters, the reaction temperature (673-873 K) and the dosage of oxidizing agent (0-0.5 stoichiometric oxygen), on the product gas composition, yield and heating value was also examined, with the reaction pressure fixed at 25 MPa.

Keywords: Biomass, Fructose, Gasification, Supercritical water.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2035
2137 Enhanced Coagulation of Disinfection By-Products Precursors in Porsuk Water Resource, Eskisehir

Authors: Zehra Yigit, Hatice Inan, Guven Seydioglu, Vedat Uyak

Abstract:

Natural organic matter (NOM) is heterogeneous mixture of organic compounds that enter the water media from animal and plant remains, domestic and industrial wastes. Researches showed that NOM is likely precursor material for disinfection by products (DBPs). Chlorine very commenly used for disinfection purposes and NOM and chlorine reacts then Trihalomethane (THM) and Haloacetic acids (HAAs) which are cancerogenics for human health are produced. The aim of the study is to search NOM removal by enhanced coagulation from drinking water source of Eskisehir which is supplied from Porsuk Dam. Recently, Porsuk dam water is getting highly polluted and therefore NOM concentration is increasing. Enhanced coagulation studies were evaluated by measurement of Dissolved Organic Carbon (DOC), UV absorbance at 254 nm (UV254), and different trihalomethane formation potential (THMFP) tests. Results of jar test experiments showed that NOM can be removed from water about 40-50 % of efficiency by enhanced coagulation. Optimum coagulant type and coagulant dosages were determined using FeCl3 and Alum.

Keywords: Chlorination, Disinfection by-products, DOC, Enhanced Coagulation, NOM, Porsuk, UV254.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2218
2136 Modeling of Single-Particle Impact in Abrasive Water Jet Machining

Authors: S. Y. Ahmadi-Brooghani, H. Hassanzadeh, P. Kahhal

Abstract:

This work presents a study on the abrasive water jet (AWJ) machining. An explicit finite element analysis (FEA) of single abrasive particle impact on stainless steel 1.4304 (AISI 304) is conducted. The abrasive water jet machining is modeled by FEA software ABAQUS/CAE. Shapes of craters in FEM simulation results were used and compared with the previous experimental and FEM works by means of crater sphericity. The influence of impact angle and particle velocity was observed. Adaptive mesh domain is used to model the impact zone. Results are in good agreement with those obtained from the experimental and FEM simulation. The crater-s depth is also obtained for different impact angle and abrasive particle velocities.

Keywords: Abrasive water jet machining, Adaptive meshcontrol, Explicit finite elements analysis, Single-particle impact.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2833
2135 Investigating the Transformer Operating Conditions for Evaluating the Dielectric Response

Authors: Jalal M. Abdallah

Abstract:

This paper presents an experimental investigation of transformer dielectric response and solid insulation water content. The dielectric response was carried out on the base of Hybrid Frequency Dielectric Spectroscopy and Polarization Current measurements method (FDS &PC). The calculation of the water content in paper is based on the water content in oil and the obtained equilibrium curves. A reference measurements were performed at equilibrium conditions for water content in oil and paper of transformer at different stable temperatures (25, 50, 60 and 70°C) to prepare references to evaluate the insulation behavior at the not equilibrium conditions. Some measurements performed at the different simulated normal working modes of transformer operation at the same temperature where the equilibrium conditions. The obtained results show that when transformer temperature is mach more than the its ambient temperature, the transformer temperature decreases immediately after disconnecting the transformer from the network and this temperature reduction influences the transformer insulation condition in the measuring process. In addition to the oil temperature at the near places to the sensors, the temperature uniformity in transformer which can be changed by a big change in the load of transformer before the measuring time will influence the result. The investigations have shown that the extremely influence of the time between disconnecting the transformer and beginning the measurements on the results. And the online monitoring for water content in paper measurements, on the basis of the oil water content on line monitoring and the obtained equilibrium curves. The measurements where performed continuously and for about 50 days without any disconnection in the prepared the adiabatic room.

Keywords: Conductivity, Moisture, Temperature, Oil-paperinsulation, Online monitoring, Water content in oil.

Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2647