	%X An electrical apparatus for measuring moisture
content was developed by our laboratory and uses dependence of
electrical properties on water content in studied material. Error
analysis of the apparatus was run by measuring different volumes of
water in a simplified specimen, i.e. hollow plexiglass block, in order
to avoid as many side-effects as possible. Obtained data were
processed using both basic and advanced statistics and results were
compared with each other. The influence of water content on
accuracy of measured data was studied as well as the influence of
variation of apparatus' proper arrangement or factual methodics of its
usage. The overall coefficient of variation was 4%. There was no
trend found in results of error dependence on water content.
Comparison with current surveys led to a conclusion, that the studied
apparatus can be used for indirect measurement of water content in
porous materials, with expectable error and under known conditions.
Factual experiments with porous materials are not involved, but are
currently under investigation.