Search results for: sacroiliac joint MRI
1084 Randomized, Controlled Blind Study Comparing Sacroiliac Intra-Articular Steroid Injection to Radiofrequency Denervation for Management of Sacroiliac Joint Pain
Authors: Ossama Salman
Abstract:
Background and objective: Sacroiliac joint pain is a common cause for chronic axial low back pain, with up to 20% prevalence rate. To date, no effective long-term treatment intervention has been embarked on yet. The aim of our study was to compare steroid block to radiofrequency ablation for SIJ pain conditions. Methods: A randomized, blind, study was conducted in 30 patients with sacroiliac joint pain. Fifteen patients received radiofrequency denervation of L4-5 primary dorsal rami and S1-3 lateral sacral branch, and 15 patients received steroid under fluoroscopy. Those in the steroid group who did not respond to steroid injections were offered to cross over to get radiofrequency ablation. Results: At 1-, 3- and 6-months post-intervention, 73%, 60% and 53% of patients, respectively, gained ≥ 50 % pain relief in the radiofrequency (RF) ablation group. In the steroid group, at one month post intervention follow up, only 20% gained ≥ 50 % pain relief, but failed to show any improvement at 3 months and 6 months follow up. Conclusions: Radiofrequency ablation at L4 and L5 primary dorsal rami and S1-3 lateral sacral branch may provide effective and longer pain relief compared to the classic intra-articular steroid injection, in properly selected patients with suspected sacroiliac joint pain. Larger studies are called for to confirm our results and lay out the optimal patient selection and treatment parameters for this poorly comprehended disorder.Keywords: lateral branch denervation, LBD, radio frequency, RF, sacroiliac joint, SIJ, visual analogue scale, VAS
Procedia PDF Downloads 2191083 Severe Bone Marrow Edema on Sacroiliac Joint MRI Increases the Risk of Low BMD in Patients with Axial Spondyloarthritis
Authors: Kwi Young Kang
Abstract:
Objective: To determine the association between inflammatory and structural lesions on sacroiliac joint (SIJ) MRI and BMD and to identify risk factors for low BMD in patients with axial spondyloarthritis (axSpA). Methods: Seventy-six patients who fulfilled the ASAS axSpA criteria were enrolled. All underwent SIJ MRI and BMD measurement at the lumbar spine, femoral neck, and total hip. Inflammatory and structural lesions on SIJ MRI were scored. Laboratory tests and assessment of radiographic and disease activity were performed at the time of MRI. The association between SIJ MRI findings and BMD was evaluated. Results: Among the 76 patients, 14 (18%) had low BMD. Patients with low BMD showed significantly higher bone marrow edema (BME) and deep BME scores on MRI than those with normal BMD (p<0.047 and 0.007, respectively). Inflammatory lesions on SIJ MRI correlated with BMD at the femoral neck and total hip. Multivariate analysis identified the presence of deep BME on SIJ MRI, increased CRP, and sacroiliitis on X-ray as risk factors for low BMD (OR: 5.6, 14.6, and 2.5, respectively). Conclusion: The presence of deep BME on SIJ MRI, increased CRP levels, and severity of sacroiliitis on X-ray were independent risk factors for low BMD.Keywords: axial spondyloarthritis, sacroiliac joint MRI, bone mineral density, sacroiliitis
Procedia PDF Downloads 5311082 Effectiveness of Myofascial Release Technique in Treatment of Sacroiliac Joint Hypo-Mobility in Postnatal Women
Authors: Ahmed A. Abd El Rahim, Mohamed M. M. Essa, Magdy M. A. Shabana, Said A. Mohamed, Mohamed Ibrahim Mabrouk
Abstract:
Background: Sacroiliac joint (SIJ) dysfunction is considered the main cause of pregnancy-related back pain, which may continue to persist postnatally. Myofascial release technique (MFR) is an application of low-intensity, prolonged stretch to myofascial structures to improve function by increasing the sliding properties of restricted myofascial tissues. Purpose: This study was designed to investigate the effect of MFR on postnatal SIJ hypo-mobility. Materials and Methods: Fifty postnatal women complaining of SIJ hypo-mobility participated in this study. Their ages ranged from 26 to 35 yrs., and their body mass index (BMI) didn`t exceed 30 kg/m2. They were randomly assigned to two equal groups, group A (Gr. A) and group B (Gr. B). Both groups received three sessions per week for eight successive weeks. Gr. A received a traditional physical therapy program, while Gr. B received a traditional physical therapy program in addition to MFR. Doppler imaging of vibration was utilized to measure SIJ mobility pre- and post-intervention, and an electronic digital goniometer was used to measure back flexion and extension Range of motion. Results: Findings revealed a statistical improvement in post-intervention values of SIJ mobility in addition to trunk flexion and extension ROM in Gr. B compared to Gr. A (P<0.001). Conclusion: Adding MFR to traditional physical therapy programs is highly recommended in the treatment of SIJ hypo-mobility in postnatal women.Keywords: sacroiliac hypo-mobility, sacroiliac dysfunction, myofascial release technique, traditional physical therapy, postnatal
Procedia PDF Downloads 991081 Computational Models for Accurate Estimation of Joint Forces
Authors: Ibrahim Elnour Abdelrahman Eltayeb
Abstract:
Computational modelling is a method used to investigate joint forces during a movement. It can get high accuracy in the joint forces via subject-specific models. However, the construction of subject-specific models remains time-consuming and expensive. The purpose of this paper was to identify what alterations we can make to generic computational models to get a better estimation of the joint forces. It appraised the impact of these alterations on the accuracy of the estimated joint forces. It found different strategies of alterations: joint model, muscle model, and an optimisation problem. All these alterations affected joint contact force accuracy, so showing the potential for improving the model predictions without involving costly and time-consuming medical images.Keywords: joint force, joint model, optimisation problem, validation
Procedia PDF Downloads 1681080 Design Modification of Lap Joint of Fiber Metal Laminates (CARALL)
Authors: Shaher Bano, Samia Fida, Asif Israr
Abstract:
The synergistic effect of properties of metals and fibers reinforced laminates has diverted attention of the world towards use of robust composite materials known as fiber-metal laminates in many high performance applications. In this study, modification of an adhesively bonded joint as a single lap joint of carbon fibers based CARALL FML has done to increase interlaminar shear strength of the joint. The effect of different configurations of joint designs such as spews, stepped and modification in adhesive by addition of nano-fillers was studied. Both experimental and simulation results showed that modified joint design have superior properties as maximum force experienced stepped joint was 1.5 times more than the simple lap joint. Addition of carbon nano-tubes as nano-fillers in the adhesive joint increased the maximum force due to crack deflection mechanism.Keywords: adhesive joint, Carbon Reinforced Aluminium Laminate (CARALL), fiber metal laminates, spews
Procedia PDF Downloads 2361079 Joint Physical Custody: Lessons from the European Union
Authors: Katarzyna Kamińska
Abstract:
When thinking about custodial arrangements after divorce or separation, there has been a shift from sole custody, particularly maternal preference, to joint physical custody. In many Western countries, an increasing of children with separated parents have joint physical custody, which is believed to be in the best interests of the child, as children can maintain personal relations and direct contact with both parents on a regular basis. The aim of the article is to examine joint physical custody, both from the perspective of the binding legal instruments that are relevant to joint physical custody, the Principles of European Family Law drafted by the CEFL, as well as the international research on this matter. The thesis underlying this paper is that joint physical custody is in itself neither good nor bad, and it depends on how the arrangements are managed by the parents. The paper includes a reflection on joint physical custody in the face of the COVID-19 crisis. The results indicate that in normal circumstances, joint physical custody demands broad communication, and now it times of crisis, we need over-communication about children and plans. Only a very tight and coordinated co-parenting plan make the whole family safer.Keywords: joint physical custody, co-parenting, child welfare, COVID-19
Procedia PDF Downloads 2431078 Seismic Response Analysis of Frame Structures Based on Super Joint Element Model
Authors: Li Xu, Yang Hong, T. Zhao Wen
Abstract:
Experimental results of many RC beam-column subassemblage indicate that slippage of longitudinal beam rebar within the joint and the shear deformation of joint core have significant influence on seismic behavior of the subassemblage. However, rigid joint assumption has been generally used in the seismic response analysis of RC frames, in which two kinds of inelastic deformation of joint have been ignored. Based on OpenSees platform, ‘Super Joint Element Model’ with more detailed inelastic mechanism is used to simulate the inelastic response of joints. Two finite element models of typical RC plane frame, namely considering or ignoring the inelastic deformation of joint respectively, were established and analyzed under seven strong earthquake waves. The simulated global and local inelastic deformations of the RC plane frame is shown and discussed. The analyses also confirm the security of the earthquake-resistant frame designed according to Chinese codes.Keywords: frame structure, beam-column joint, longitudinal bar slippage, shear deformation, nonlinear analysis
Procedia PDF Downloads 4081077 The Effect of Impact on the Knee Joint Due to the Shocks during Double Impact Phase of Gait Cycle
Authors: Jobin Varghese, V. M. Akhil, P. K. Rajendrakumar, K. S. Sivanandan
Abstract:
The major contributor to the human locomotion is the knee flexion and extension. During heel strike, a huge amount of energy is transmitted through the leg towards knee joint, which in fact is damped at heel and leg muscles. During high shocks, although it is damped to a certain extent, the balance force transmits towards knee joint which could damage the knee. Due to the vital function of the knee joint, it should be protected against damage due to additional load acting on it. This work concentrates on the development of spring mass damper system which exactly replicates the stiffness at the heel and muscles and the objective function is optimized to minimize the force acting at the knee joint. Further, the data collected using force plate are put into the model to verify its integrity and are found to be in good agreement.Keywords: spring, mass, damper, knee joint
Procedia PDF Downloads 2701076 Joint Physical Custody after Divorce and Child Well-Being
Authors: Katarzyna Kamińska
Abstract:
Joint physical custody means that both parents after divorce or separation have the right and responsibility to take care of the child on the daily basis. In a joint physical custody arrangement, the child spends substantial, but not necessarily equal, time with both parents. Joint physical custody can be symmetric care arrangement or not. However, it is accepted in the jurisprudence that the best interests of the child is served when the child spends at least 35% of the time during a two-week period with each parent. Joint physical custody, also known as joint, dual, or shared residence, is a challenge in contemporary family law. It has its supporters and opponents. On the one hand, joint physical custody is beneficial because it provides children with frequent and continuous contact with a mother and father after their divorce or separation. On the other hand, it isn’t good for children to be shuttled back and forth between two residences. Children need a home base. The conclusion is therefore that joint physical custody can’t be seen as a panacea for all post-divorce or post-separation parenting cases and the court shouldn’t automatically make such a determination. The possibility to award this arrangement requires the court to carefully weigh the pros and cons of each individual case. It is difficult to say that joint physical custody is better than single physical custody in any case. It depends on the circumstances and needs of each family. It appears that an individual approach is going to be much better as opposed to a one-size-fits-all idea.Keywords: joint physical custody, shared residence, dual residence, the best interests of the child
Procedia PDF Downloads 921075 The Nonlinear Research on Rotational Stiffness of Cuplock Joint
Authors: Liuyu Zhang, Di Mo, Qiang Yan, Min Liu
Abstract:
As the important equipment in the construction field, cuplock scaffold plays an important role in the construction process. As a scaffold connecting member, cuplock joint is of great importance. In order to explore the rotational stiffness nonlinear characteristics changing features of different structural forms of cuplock joint in different tightening torque condition under different conditions of load, ANSYS is used to establish four kinds of cuplock joint models with different forces to simulate the real force situation. By setting the different load conditions which means the cuplock is loaded at a certain distance from the cuplock joint in a certain direction until the cuplock is damaged and considering the gap between the cross bar joint and the vertical bar, the differences in the influence of the structural form and tightening torque on the rotation stiffness of the cuplock under different load conditions are compared. It is significantly important to improve the accuracy of calculating bearing capacity and stability of the cuplock steel pipe scaffold.Keywords: cuplock joint, highway tunnel, non-linear characteristics, rotational stiffness, scaffold stability, theoretical analysis
Procedia PDF Downloads 1211074 The Problem of Legal Regulation of Joint Physical Custody: The Polish Perspective
Authors: Katarzyna Kamińska
Abstract:
The main purpose of the work is to present the results of the studies regarding joint physical custody in the Polish legal system. The issues addressed fit into the ongoing process of modernising family law regulations and their adaptation to changing social reality in Poland. The Polish legislator now faces a dilemma: whether to introduce into Polish law a developed substantive or procedural regulation of joint physical custody and then whether it should be considered a legal presumption. Joint physical custody after divorce or separation is theoretically possible in Poland. It can either follow from the court’s independent proposal based on the assessment of the circumstances or from the parenting plan submitted by parents wishing to jointly retain full parental authority. However, joint physical custody does not result directly from the Polish Family and Guardianship Code. Therefore, there is real legal uncertainty in this matter, which leads to different treatment of citizens by the public authorities and courts. Another problem is that joint physical custody is misunderstood by the Polish courts. The main thesis of the work is that joint physical custody does not only mean the system of symmetrical child care (50/50), and the possibility to award joint physical custody will require the courts to carefully weigh the pros and cons of such an arrangement in each individual case.Keywords: joint physical custody, shared parenting, divorce, separation, parental authority
Procedia PDF Downloads 821073 The Effect of Tool Type on Surface Morphology of FSJ Joint
Authors: Yongfang Deng, Dunwen Zuo
Abstract:
An attempt is made here to join 2024 aluminum alloy plate by friction stir joining (FSJ) using different types of tools. Joint surface morphology was observed, and both arc line spacing and flash were measured. Study is carried out on the effect of pin, shoulder and eccentricity of the tool on the surface topography of the joint and the formation of the joint surface topography is analyzed. It is found that, eccentric squeezing action of the tool is the mainly motive power to form arc lines contour and flash structure. Little flash appears in the advancing side but with severe deformation, while the flash in the retreating side is heavy but with soft deformation. The pin of tool has a deep impact on the flash on the advancing side of the joints. Shoulder can widen the arc lines, refine arcs structure, reduce flash in the retreat side, but will increase the flash in the advancing side. Increasing the amount of eccentricity, it has litter effect on the arc line spacing but will destroy the arc lines morphology in the joint surface and promote the formation of filamentous flash structure in the joint.Keywords: FSJ, surface morphology, tool, joint
Procedia PDF Downloads 3621072 Development of a New Method for T-Joint Specimens Testing under Shear Loading
Authors: Radek Doubrava, Roman Ruzek
Abstract:
Nonstandard tests are necessary for analyses and verification of new developed structural and technological solutions with application of composite materials. One of the most critical primary structural parts of a typical aerospace structure is T-joint. This structural element is loaded mainly in shear, bending, peel and tension. The paper is focused on the shear loading simulations. The aim of the work is to obtain a representative uniform distribution of shear loads along T-joint during the mechanical testing is. A new design of T-joint test procedure, numerical simulation and optimization of representative boundary conditions are presented. The different conditions and inaccuracies both in simulations and experiments are discussed. The influence of different parameters on stress and strain distributions is demonstrated on T-joint made of CFRP (carbon fiber reinforced plastic). A special test rig designed by VZLU (Aerospace Research and Test Establishment) for T-shear test procedure is presented.Keywords: T-joint, shear, composite, mechanical testing, finite element analysis, methodology
Procedia PDF Downloads 4411071 Short Term Effects of Mobilization with Movement in a Patient with Fibromyalgia: A Case Report
Authors: S. F. Kanaan, Fatima Al-Kadi, H. Khrais
Abstract:
Background: Fibromyalgia is a chronic condition that is characterized by chronic pain that limits physical and functional activities. To our best knowledge, there is currently no key physiotherapy approach recommended to reduce pain and improve function. In addition, there are scarce studies that investigated the effect of manual therapy in the management of Fibromyalgia, and no study investigated the efficacy of Mulligan´s mobilization with movement (MWM) in particular. Methods: A 51-year-old female diagnosed with Fibromyalgia for more than a year. The patient was complaining of generalized pain including neck, lower back, shoulders, elbows, hips, and knees. In addition, the patient reported severe limitation in activities and inability to complete her work as a lawyer. The Intervention provided for the patient consisted of 4 sessions (in two weeks) of MWM for neck, lower back, shoulders, elbows, sacroiliac joint, hips, and knees. The Visual Analogue Scale of pain (VAS), Range of Motion (ROM), 10-minute walk test, Roland Morris Low Back Pain and Disability Questionnaire (RMQ), Disability of the Arm, Shoulder and Hand Score (DASH) were collected at the baseline and at the end of treatment. Results: Average improvement of ROM in the neck, lower back, shoulder, elbows, hips, and knees was 45%. VAS scale changed from pre-treatment to post-treatment as the following: neck pain (9 to 0), lower back pain (8 to 1), shoulders pain (8 to 2), elbows pain (7 to 1), and knees pain (9 to 0). The patient demonstrated improvement in all functional scale from pre-intervention to post-intervention: 10-meter walk test (9.8 to 4.5 seconds), RMQ (21 to 11/24), and DASH (88.7% to 40.5%). The patient did not report any side effect of using this approach. Conclusion: Fibromyalgia can cause joint 'faulty position' leading to pain and dysfunction, which can be reversed by using MWM. MWM showed to have clinically significant improvement in ROM, pain, and ability to walk and a clinically significant reduction in disability in only 4 sessions. This work can be expanded in a larger sample.Keywords: mobilization, fibromyalgia, dysfunction, manual therapy
Procedia PDF Downloads 1731070 Numerical Prediction of Bearing Strength on Composite Bolted Joint Using Three Dimensional Puck Failure Criteria
Authors: M. S. Meon, M. N. Rao, K-U. Schröder
Abstract:
Mechanical fasteners especially bolting is commonly used in joining carbon-fiber reinforced polymer (CFRP) composite structures due to their good joinability and easy for maintenance characteristics. Since this approach involves with notching, a proper progressive damage model (PDM) need to be implemented and verified to capture existence of damages in the structure. A three dimensional (3D) failure criteria of Puck is established to predict the ultimate bearing failure of such joint. The failure criteria incorporated with degradation scheme are coded based on user subroutine executed in Abaqus. Single lap joint (SLJ) of composite bolted joint is used as target configuration. The results revealed that the PDM adopted here could sufficiently predict the behaviour of composite bolted joint up to ultimate bearing failure. In addition, mesh refinement near holes increased the accuracy of predicted strength as well as computational effort.Keywords: bearing strength, bolted joint, degradation scheme, progressive damage model
Procedia PDF Downloads 4991069 Evaluation of Joint Contact Forces and Muscle Forces in the Subjects with Non-Specific Low Back Pain
Authors: Mohammad Taghi Karimi, Maryam Hasan Zahraee
Abstract:
Background: Low back pain (LBP) is a common health and socioeconomic problem, especially the chronic one. The joint contact force is an important parameter during walking which increases the incidence of injury and degenerative joint disease. To our best knowledge, there are not enough evidences in literature on the muscular forces and joint contact forces in subjects with low back pain. Purpose: The main hypothesis associated with this research was that joint contact force of L4/L5 of non-specific chronic low back pain subjects was the same as that of normal. Therefore, the aim of this study was to determine the joint contact force difference between non-specific chronic low back pain and normal subjects. Method: This was an experimental-comparative study. 20 normal subjects and 20 non-specific chronic low back pain patients were recruited in this study. Qualysis motion analysis system and a Kistler force plate were used to collect the motions and the force applied on the leg, respectively. OpenSimm software used to determine joint contact force and muscle forces in this study. Some parameters such as force applied on the legs (pelvis), kinematic of hip and pelvic, peaks of muscles, force of trunk musculature and joint contact force of L5/S1 were used for further analysis. Differences between mean values of all data were measured using two-sample t-test among the subjects. Results: The force produced by Semitendinosus, Biceps Femoris, and Adductor muscles were significantly different between low back pain and normal subjects. Moreover, the mean value of breaking component of the force of the knee joint increased significantly in low back pain subjects, besides a significant decrease in mean value of the vertical component of joint reaction force compared to the normal ones. Conclusions: The forces produced by the trunk and pelvic muscles, and joint contact forces differ significantly between low back pain and normal subjects. It seems that those with non-specific chronic low back pain use trunk muscles more than normal subjects to stabilize the pelvic during walking.Keywords: low back pain, joint contact force, kinetic, muscle force
Procedia PDF Downloads 2371068 Analysis of Artificial Hip Joint Using Finite Element Method
Authors: Syed Zameer, Mohamed Haneef
Abstract:
Hip joint plays very important role in human beings as it takes up the whole body forces generated due to various activities. These loads are repetitive and fluctuating depending on the activities such as standing, sitting, jogging, stair casing, climbing, etc. which may lead to failure of Hip joint. Hip joint modification and replacement are common in old aged persons as well as younger persons. In this research study static and Fatigue analysis of Hip joint model was carried out using finite element software ANSYS. Stress distribution obtained from result of static analysis, material properties and S-N curve data of fabricated Ultra High molecular weight polyethylene / 50 wt% short E glass fibres + 40 wt% TiO2 Polymer matrix composites specimens were used to estimate fatigue life of Hip joint using stiffness Degradation model for polymer matrix composites. The stress distribution obtained from static analysis was found to be within the acceptable range.The factor of safety calculated from linear Palmgren linear damage rule is less than one, which indicates the component is safe under the design.Keywords: hip joint, polymer matrix composite, static analysis, fatigue analysis, stress life approach
Procedia PDF Downloads 3561067 Biomechanical Study of a Type II Superior Labral Anterior to Posterior Lesion in the Glenohumeral Joint Using Finite Element Analysis
Authors: Javier A. Maldonado E., Duvert A. Puentes T., Diego F. Villegas B.
Abstract:
The SLAP lesion (Superior Labral Anterior to Posterior) involves the labrum, causing pain and mobility problems in the glenohumeral joint. This injury is common in athletes practicing sports that requires throwing or those who receive traumatic impacts on the shoulder area. This paper determines the biomechanical behavior of soft tissues of the glenohumeral joint when type II SLAP lesion is present. This pathology is characterized for a tear in the superior labrum which is simulated in a 3D model of the shoulder joint. A 3D model of the glenohumeral joint was obtained using the free software Slice. Then, a Finite Element analysis was done using a general purpose software which simulates a compression test with external rotation. First, a validation was done assuming a healthy joint shoulder with a previous study. Once the initial model was validated, a lesion of the labrum built using a CAD software and the same test was done again. The results obtained were stress and strain distribution of the synovial capsule and the injured labrum. ANOVA was done for the healthy and injured glenohumeral joint finding significant differences between them. This study will help orthopedic surgeons to know the biomechanics involving this type of lesion and also the other surrounding structures affected by loading the injured joint.Keywords: biomechanics, computational model, finite elements, glenohumeral joint, superior labral anterior to posterior lesion
Procedia PDF Downloads 2071066 Neural Networks for Distinguishing the Performance of Two Hip Joint Implants on the Basis of Hip Implant Side and Ground Reaction Force
Authors: L. Parisi
Abstract:
In this research work, neural networks were applied to classify two types of hip joint implants based on the relative hip joint implant side speed and three components of each ground reaction force. The condition of walking gait at normal velocity was used and carried out with each of the two hip joint implants assessed. Ground reaction forces’ kinetic temporal changes were considered in the first approach followed but discarded in the second one. Ground reaction force components were obtained from eighteen patients under such gait condition, half of which had a hip implant type I-II, whilst the other half had the hip implant, defined as type III by Orthoload®. After pre-processing raw gait kinetic data and selecting the time frames needed for the analysis, the ground reaction force components were used to train a MLP neural network, which learnt to distinguish the two hip joint implants in the abovementioned condition. Further to training, unknown hip implant side and ground reaction force components were presented to the neural networks, which assigned those features into the right class with a reasonably high accuracy for the hip implant type I-II and the type III. The results suggest that neural networks could be successfully applied in the performance assessment of hip joint implants.Keywords: kinemic gait data, neural networks, hip joint implant, hip arthroplasty, rehabilitation engineering
Procedia PDF Downloads 3541065 Measuring Audit Quality Using Text Analysis: An Empirical Study of Indian Companies
Authors: Leesa Mohanty, Ashok Banerjee
Abstract:
Better audit quality signifies the financial statements of the auditee firm reflect true and fair view of their actual state of affairs, which reduces information asymmetry between management and shareholders, as a result, helps protect interests of shareholders. This study examines the impact of joint audit on audit quality. It is motivated by the ongoing debate where The Institute of Chartered Accountants of India (ICAI), the regulatory body governing auditors, has advocated the finance ministry and the Reserve Bank of India (RBI) for the mandatory use of joint audit in private banks to enhance the quality of audit. Earlier, the Government of India had rejected the plea by ICAI for mandatory joint audits in large companies stating it is not a viable option for promoting domestic firms. We introduce a new measure of audit quality. Drawing from the domain of text analytics, we use relevant phrases in audit reports to gauge audit quality and demonstrate that joint audit improves audit quality. We also, for robustness, use prevalent proxy for audit quality (Big N Auditor, ratio of audit fees to total fees) and find negative effect of joint audit on audit quality. We, therefore highlight that different proxy for audit quality show opposite effect of joint audit.Keywords: audit fees, audit quality, Big N. Auditor, joint audit
Procedia PDF Downloads 3561064 Organism Profile Causing Prosthetic Joint Infection Continues to Evolve
Authors: Bahaa Eldin Kornah
Abstract:
The organism profile for peri-prosthetic joint infection caused by hematogenous seeding or direct inoculations is changing. The organisms that cause prosthetic joint infections range from normal skin colonizers to highly virulent pathogens. The pathogens continue to evolve. While Staphylococcus aureus continues to be the leading organism, gram-negative bacilli account for approximately 7% of cases and that incidence is increasing. Methicillin-resistant S. aureus(MRSA) accounts for approximately 10% of all infections occurring in the community setting and 20% of those in the health care setting. The list of organisms causing PJI has expanded in recent years. It is important to have an understanding of which organisms may be causing a periprosthetic joint infection based on where the patient contracted it and their recent medical history. Also, recent technology has expanded rapidly and new methods to detect the pathogen and why we failed in detecting it. There are a number of explanations for the latter finding, perhaps the most important reason being the liberal use of antibiotics that interferes with the isolation of the infective organism.Keywords: infection, periprosthetic, hip, organism profile, joint infection, joint infection
Procedia PDF Downloads 841063 A Numerical Study of Adherend Geometry on the Stress Distribution in Adhesively Lap Joint
Authors: Ahmet Calik
Abstract:
In present study, the effect of adherend geometry on the tensile strength of adhesively single lap aluminum structures joint, bonded was numerically studied using by three dimensional finite element model. Six joint model were investigated. Analyses were performed in ANSYS commercial software. The results shows that the adherends shape has the highest effect on peel and shear stresses.Keywords: adhesive, adherend, single lap joints, finite element
Procedia PDF Downloads 2911062 Pushover Experiment of Traditional Dieh-Dou Timber Frame
Authors: Ren Zuo Wang
Abstract:
In this paper, in order to investigate the joint behaviors of the Dieh-Dou structure. A pushover experiment of Dieh-Dou Jia-Dong is implemented. NDI, LVDT and image measurement system are used to measure displacements of joints and deformations of Dieh-Dou Jia-Dong. In addition, joint rotation-moment relationships of column restoring force, purlin-supporting, Dou-Shu, Dou-Gong brackets, primary beam-Gua Tong, secondary beam-Gua Tong, Tertiary beam are builied. From Jia-Dong experiments, formulations of joint rotation are proposed.Keywords: pushover experiment, Dieh-Dou timber frame, image measurement system, joint rotation-moment relationships
Procedia PDF Downloads 4441061 Composite Behavior of Precast Concrete Coping with Internal Connector and Precast Girder
Authors: Junki Min, Heeyoung Lee, Wonseok Chung
Abstract:
Traditional marine concrete structures are difficult to construct and may cause environmental pollution. This study presents new concrete bridge system in the marine. The main feature of the proposed bridge is that precast girders and precast coping are applied to facilitate assembly and to improve constructability. In addition, the moment of the girder is reduced by continuation the joint. In this study, a full-scale joint specimen with a span of 7.0 m was fabricated and tested to evaluate the composite behavior of the joint. A finite element model was also developed and compared against the experimental results. All members of the test specimen behaved stably up to the design load. It was found that the precast joint of the proposed bridge showed the composite behavior efficiently before the failure.Keywords: finite element analysis, full-scale test, coping, joint performance, marine structure, precast
Procedia PDF Downloads 2041060 Experimental Study on Connection Method of Precast Beam-Column Using CFRPS
Authors: Harmonis Rante, Rudy Djamaluddin, Herman Parung, Victor Sampebulu
Abstract:
Many research of FRP strengthening on beam-column joint have been done. They used FRP as a strengthening material but not as a connection method. This paper presents a result of experimental-study on connection method of precast beam-column using CFRP sheet to investigate the possibility of CFRP sheet to be a connecting material. Six specimens were prepared and tested to investigate the behavior of CFRP-s connection capacity. The performance of two-connection method is presented in this paper. Three specimens have been tested so far, they were specimen without belt, specimen using one belt and monolith specimen as a control specimen. Result indicated that FRP joint system without belt reached higher capacity than joint system using one belt, but both are lower than monolith joint. Capacity of joint system without belt is 90.6% and 62.5% for the joint system using one belt, respectively compared to the control specimen.Keywords: belt, CFRP-s, connection method, strengthening
Procedia PDF Downloads 2501059 Testing of the Decreasing Bond Strength of Polyvinyl Acetate Adhesive by Low Temperatures
Authors: Pavel Boška, Jan Bomba, Tomáš Beránek, Jiří Procházka
Abstract:
When using wood products bonded by polyvinyl acetate, glues such as windows are the most limiting element of degradation of the glued joint due to weather changes. In addition to moisture and high temperatures, the joint may damage the low temperature below freezing point, where dimensional changes in the material and distortion of the adhesive film occur. During the experiments, the joints were exposed to several degrees of sub-zero temperatures from 0 °C to -40 °C and then to compare how the decreasing temperature affects the strength of the joint. The experiment was performed on wood beech samples (Fagus sylvatica), bonded with PVAc with D3 resistance and the shear strength of bond was measured. The glued and treated samples were tested on a laboratory testing machine, recording the strength of the joint. The statistical results have given us information that the strength of the joint gradually decreases with decreasing temperature, but a noticeable and statistically significant change is achieved only at very low temperatures.Keywords: adhesives, bond strength, low temperatures, polyvinyl acetate
Procedia PDF Downloads 3481058 Biases in Numerically Invariant Joint Signatures
Authors: Reza Aghayan
Abstract:
This paper illustrates that numerically invariant joint signatures suffer biases in the resulting signatures. Next, we classify the arising biases as Bias Type 1 and Bias Type 2 and show how they can be removed.Keywords: Euclidean and affine geometries, differential invariant signature curves, numerically invariant joint signatures, numerical analysis, numerical bias, curve analysis
Procedia PDF Downloads 5951057 Finite Element Modelling of Log Wall Corner Joints
Authors: Reza Kalantari, Ghazanfarah Hafeez
Abstract:
The paper presents outcomes of the numerical research performed on standard and dovetail corner joints under lateral loads. An overview of the past research on log shear walls is also presented. To the authors’ best knowledge, currently, there are no specific design guidelines available in the code for the design of log shear walls, implying the need to investigate the performance of log shear walls. This research explores the performance of the log shear wall corner joint system of standard joint and dovetail types using numerical methods based on research available in the literature. A parametric study is performed to study the effect of gap size provided between two orthogonal logs and the presence of wood and steel dowels provided as joinery between log courses on the performance of such a structural system. The research outcomes are the force-displacement curves. 8% variability is seen in the reaction forces with the change of gap size for the case of the standard joint, while a variation of 10% is observed in the reaction forces for the dovetail joint system.Keywords: dovetail joint, finite element modelling, log shear walls, standard joint
Procedia PDF Downloads 2131056 Improved Performance Scheme for Joint Transmission in Downlink Coordinated Multi-Point Transmission
Authors: Young-Su Ryu, Su-Hyun Jung, Myoung-Jin Kim, Hyoung-Kyu Song
Abstract:
In this paper, improved performance scheme for joint transmission is proposed in downlink (DL) coordinated multi-point(CoMP) in case of constraint transmission power. This scheme is that serving transmission point (TP) request a joint transmission to inter-TP and selects one pre-coding technique according to channel state information(CSI) from user equipment(UE). The simulation results show that the bit error rate(BER) and throughput performances of the proposed scheme provide high spectral efficiency and reliable data at the cell edge.Keywords: CoMP, joint transmission, minimum mean square error, zero-forcing, zero-forcing dirty paper coding
Procedia PDF Downloads 5511055 Analysis study According Some of Physical and Mechanical Variables for Joint Wrist Injury
Authors: Nabeel Abdulkadhim Athab
Abstract:
The purpose of this research is to conduct a comparative study according analysis of programmed to some of physical and mechanical variables for joint wrist injury. As it can be through this research to distinguish between the amount of variation in the work of the joint after sample underwent rehabilitation program to improve the effectiveness of the joint and naturally restore its effectiveness. Supposed researcher that there is statistically significant differences between the results of the tests pre and post the members research sample, as a result of submission the sample to the program of rehabilitation, which led to the development of muscle activity that are working on wrist joint and this is what led to note the differences between the results of the tests pre and post. The researcher used the descriptive method. The research sample included (6) of injured players in the wrist joint, as the average age (21.68) and standard deviation (1.13) either length average (178cm) and standard deviation (2.08). And the sample as evidenced homogeneous among themselves. And where the data were collected, introduced in program for statistical processing to get to the most important conclusions and recommendations and that the most important: 1-The commitment of the sample program the qualifying process variables studied in the search for the heterogeneity of study activity and effectiveness of wrist joint for injured players. 2-The analysis programmed a high accuracy in the measurement of the research variables, and which led to the possibility of discrimination into account differences in motor ability camel and injured in the wrist joint. To search recommendations including: 1-The use of computer systems in the scientific research for the possibility of obtaining accurate research results. 2-Programming exercises rehabilitation according to an expert system for possible use by patients without reference to the person processor.Keywords: analysis of joint wrist injury, physical and mechanical variables, wrist joint, wrist injury
Procedia PDF Downloads 430