Search results for: contrast sensitivity
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3333

Search results for: contrast sensitivity

2463 Implementing Universal Design for Learning in Social Work Education

Authors: Kaycee Bills

Abstract:

Action research is a method of inquiry useful in solving social problems in social work. This study seeks to address a significant problem: higher education’s use of traditional instructional methods in social work education. Ineffective techniques, such as lecturing, fail to account for students’ variable learning needs. In contrast to traditional pedagogy, universal design for learning (UDL) is a robust framework that '[improves] and [optimizes] teaching and learning for all people' (CAST, 2018), including students with disabilities. For this project, the research team interviewed the UDL and Accessibility Specialist at their institution for two reasons: (1) to learn how to implement UDL practices in their classrooms, and in turn, (2) to motivate other faculty members at their institution to consider enacting UDL principles. A thematic analysis of the interview’s transcript reveals themes relevant to practicing UDL. Implications for future practice, as well as the researcher’s reflections on the research process, are shared in the discussion section.

Keywords: disabilities, higher education, inclusive education, universal design for learning

Procedia PDF Downloads 128
2462 BOX Effect Sensitivity to Fin Width in SOI-Multi-FinFETs

Authors: A. N. Moulai Khatir

Abstract:

SOI-Multifin-FETs are placed to be the workhorse of the industry for the coming few generations, and thus, in a few years because their excellent transistor characteristics, ideal sub-threshold swing, low drain induced barrier lowering (DIBL) without pocket implantation, and negligible body bias dependency. The corner effect may also exist in the two lower corners; this effect is called the BOX effect, which can also occur in the direction X-Z. The electric field lines from the source and drain cross the bottom oxide and arrive in the silicon. This effect is also called DIVSB (Drain Induced Virtual Substrate Basing). The potential in the silicon film in particular near the drain is increased by the drain bias. It is similar to DIBL and result in a decrease of the threshold voltage. This work provides an understanding of the limitation of this effect by reducing the fin width for components with increased fin number.

Keywords: SOI, finFET, corner effect, dual-gate, tri-gate, BOX, multi-finFET

Procedia PDF Downloads 496
2461 Intraventricular Hemorrhage Caused by Subarachnoid Hemorrhage; When Time Is Life

Authors: Devieta Romadhon Saendardy

Abstract:

Introduction: The case of aneurysmal subarachnoid hemorrhage (SAH) associated with intraventricular hemorrhage (IVH) in many way. In general, the anterior communicating artery and posterior circulation aneurysms cause Intraventricular Hemorrhage. The development of intraventricular hemorrhage (IVH) in aneurysmal subarachnoid hemorrhage (aSAH) is linked with higher mortality and poor neurological recovery. Case: This case report presents a 51-year-old female patient who developed IVH following SAH. The patient's Glasgow Coma Scale score was 14, the patient has a severe headache, and there were right extremity hemipharese neurological deficits. A non-contrast head CT scan revealed a massive intraventricular haemorrhage. In an hour, the patient got her headache and pharese worse. Discussion: Intraventricular hemorrhage is a serious complication of subarachnoid hemorrhage, necessitating prompt recognition and management. This case highlights the importance of a time management, medical management and surgical intervention to optimize outcomes in patients with intraventricular hemorrhage caused by subarachnoid hemorrhage. Placement of a shunt system improves clinical outcome in intraventricular hemorrhage.

Keywords: Intraventricular hemorrhage, subarachnoid hemorrhage, shunt, time

Procedia PDF Downloads 71
2460 Ultrasensitive Hepatitis B Virus Detection in Blood Using Nano-Porous Silicon Oxide: Towards POC Diagnostics

Authors: N. Das, N. Samanta, L. Pandey, C. Roy Chaudhuri

Abstract:

Early diagnosis of infection like Hep-B virus in blood is important for low cost medical treatment. For this purpose, it is desirable to develop a point of care device which should be able to detect trace quantities of the target molecule in blood. In this paper, we report a nanoporous silicon oxide sensor which is capable of detecting down to 1fM concentration of Hep-B surface antigen in blood without the requirement of any centrifuge or pre-concentration. This has been made possible by the presence of resonant peak in the sensitivity characteristics. This peak is observed to be dependent only on the concentration of the specific antigen and not on the interfering species in blood serum. The occurrence of opposite impedance change within the pores and at the bottom of the pore is responsible for this effect. An electronic interface has also been designed to provide a display of the virus concentration.

Keywords: impedance spectroscopy, ultrasensitive detection in blood, peak frequency, electronic interface

Procedia PDF Downloads 400
2459 Determine the Optimal Path of Content Adaptation Services with Max Heap Tree

Authors: Shilan Rahmani Azr, Siavash Emtiyaz

Abstract:

Recent development in computing and communicative technologies leads to much easier mobile accessibility to the information. Users can access to the information in different places using various deceives in which the care variety of abilities. Meanwhile, the format and details of electronic documents are changing each day. In these cases, a mismatch is created between content and client’s abilities. Recently the service-oriented content adaption has been developed which the adapting tasks are dedicated to some extended services. In this method, the main problem is to choose the best appropriate service among accessible and distributed services. In this paper, a method for determining the optimal path to the best services, based on the quality control parameters and user preferences, is proposed using max heap tree. The efficiency of this method in contrast to the other previous methods of the content adaptation is related to the determining the optimal path of the best services which are measured. The results show the advantages and progresses of this method in compare of the others.

Keywords: service-oriented content adaption, QoS, max heap tree, web services

Procedia PDF Downloads 259
2458 Functionalization of Nanomaterials for Bio-Sensing Applications: Current Progress and Future Prospective

Authors: Temesgen Geremew Tefery

Abstract:

Nanomaterials, due to their unique properties, have revolutionized the field of biosensing. Their functionalization, or modification with specific molecules, is crucial for enhancing their biocompatibility, selectivity, and sensitivity. This review explores recent advancements in nanomaterial functionalization for biosensing applications. We discuss various strategies, including covalent and non-covalent modifications, and their impact on biosensor performance. The use of biomolecules like antibodies, enzymes, and nucleic acids for targeted detection is highlighted. Furthermore, the integration of nanomaterials with different sensing modalities, such as electrochemical, optical, and mechanical, is examined. The future outlook for nanomaterial-based biosensing is promising, with potential applications in healthcare, environmental monitoring, and food safety. However, challenges related to biocompatibility, scalability, and cost-effectiveness need to be addressed. Continued research and development in this area will likely lead to even more sophisticated and versatile biosensing technologies.

Keywords: biosensing, nanomaterials, biotechnology, nanotechnology

Procedia PDF Downloads 27
2457 Influence of Transformation Leadership Style on Employee Engagement among Generation Y

Authors: Z. D. Mansor, C. P. Mun, B. S. Nurul Farhana, Wan Aisyah Nasuha Wan Mohamed Tarmizi

Abstract:

The aim of this research is to determine the influence of transformation leadership style on employee engagement among Generation Y. The growing of Generation Y employees in Malaysia has raised concerns about how to engage and motivate this cohort. Transformation Leadership style is one of the key factors to increase employee engagement levels in the organization. This study has proven to be important for the researchers and the organization to properly understand the concept of employee engagement, transformation leadership style and their relationship. The samples in this study included 221 respondents of Generation Y who are currently working in Selangor and Klang Valley area in Malaysia. The data were collected using questionnaires and analyzed by using Statistical Package for Social Science (SPSS). The results show that there is a significant relationship between the dimension of intellectual stimulation, inspiration motivation and individual consideration on employee engagement. In contrast, the results have revealed that there is no significant relationship between idealized influences of a leader on employee engagement among Generation Y.

Keywords: employee engagement, transformational leadership styles, gen Y, survey

Procedia PDF Downloads 343
2456 Surveillance of Super-Extended Objects: Bimodal Approach

Authors: Andrey V. Timofeev, Dmitry Egorov

Abstract:

This paper describes an effective solution to the task of a remote monitoring of super-extended objects (oil and gas pipeline, railways, national frontier). The suggested solution is based on the principle of simultaneously monitoring of seismoacoustic and optical/infrared physical fields. The principle of simultaneous monitoring of those fields is not new but in contrast to the known solutions the suggested approach allows to control super-extended objects with very limited operational costs. So-called C-OTDR (Coherent Optical Time Domain Reflectometer) systems are used to monitor the seismoacoustic field. Far-CCTV systems are used to monitor the optical/infrared field. A simultaneous data processing provided by both systems allows effectively detecting and classifying target activities, which appear in the monitored objects vicinity. The results of practical usage had shown high effectiveness of the suggested approach.

Keywords: C-OTDR monitoring system, bimodal processing, LPboost, SVM

Procedia PDF Downloads 469
2455 A Numerical Model Simulation for an Updraft Gasifier Using High-Temperature Steam

Authors: T. M. Ismail, M. A. El-Salam

Abstract:

A mathematical model study was carried out to investigate gasification of biomass fuels using high-temperature air and steam as a gasifying agent using high-temperature air up to 1000°C. In this study, a 2D computational fluid dynamics model was developed to study the gasification process in an updraft gasifier, considering drying, pyrolysis, combustion, and gasification reactions. The gas and solid phases were resolved using a Euler−Euler multiphase approach, with exchange terms for the momentum, mass, and energy. The standard k−ε turbulence model was used in the gas phase, and the particle phase was modeled using the kinetic theory of granular flow. The results show that the present model giving a promising way in its capability and sensitivity for the parameter effects that influence the gasification process.

Keywords: computational fluid dynamics, gasification, biomass fuel, fixed bed gasifier

Procedia PDF Downloads 406
2454 Optimal Rotor Design of an 150kW-Class IPMSM through the 3D Voltage-Inductance Map Analysis Method

Authors: Eung-Seok Park, Tae-Chul Jeong, Hyun-Jong Park, Hyun-Woo Jun, Dong-Woo Kang, Ju Lee

Abstract:

This presents a methodology to determine detail design directions of an 150kW-class IPMSM (interior permanent magnet synchronous motor) and its detail design. The basic design of the stator and rotor was conducted. After dividing the designed models into the best cases and the worst cases based on rotor shape parameters, Sensitivity analysis and 3D Voltage-Inductance Map (3D EL-Map) parameters were analyzed. Then, the design direction for the final model was predicted. Based on the prediction, the final model was extracted with Trend analysis. Lastly, the final model was validated with experiments.

Keywords: PMSM, optimal design, rotor design, voltage-inductance map

Procedia PDF Downloads 673
2453 Nano-Immunoassay for Diagnosis of Active Schistosomal Infection

Authors: Manal M. Kame, Hanan G. El-Baz, Zeinab A.Demerdash, Engy M. Abd El-Moneem, Mohamed A. Hendawy, Ibrahim R. Bayoumi

Abstract:

There is a constant need to improve the performance of current diagnostic assays of schistosomiasis as well as develop innovative testing strategies to meet new testing challenges. This study aims at increasing the diagnostic efficiency of monoclonal antibody (MAb)-based antigen detection assays through gold nanoparticles conjugated with specific anti-Schistosoma mansoni monoclonal antibodies. In this study, several hybidoma cell lines secreting MAbs against adult worm tegumental Schistosoma antigen (AWTA) were produced at Immunology Department of Theodor Bilharz Research Institute and preserved in liquid nitrogen. One MAb (6D/6F) was chosen for this study due to its high reactivity to schistosome antigens with highest optical density (OD) values. Gold nanoparticles (AuNPs) were functionalized and conjugated with MAb (6D/6F). The study was conducted on serum samples of 116 subjects: 71 patients with S. mansoni eggs in their stool samples group (gp 1), 25 with other parasites (gp2) and 20 negative healthy controls (gp3). Patients in gp1 were further subdivided according to egg count in their stool samples into Light infection {≤ 50 egg per gram(epg) (n= 17)}, moderate {51-100 epg (n= 33)} and severe infection {>100 epg(n= 21)}. Sandwich ELISA was performed using (AuNPs -MAb) for detection of circulating schistosomal antigen (CSA) levels in serum samples of all groups and the results were compared with that after using MAb/ sandwich ELISA system. Results Gold- MAb/ ELISA system reached a lower detection limit of 10 ng/ml compared to 85 ng/ml on using MAb/ ELISA and the optimal concentrations of AuNPs -MAb were found to be 12 folds less than that of MAb/ ELISA system for detection of CSA. The sensitivity and specificity of sandwich ELISA for detection of CSA levels using AuNPs -MAb were 100% & 97.8 % respectively compared to 87.3% &93.38% respectively on using MAb/ ELISA system. It was found that CSA was detected in 9 out of 71 S.mansoni infected patients on using AuNPs - MAb/ ELISA system and was not detected by MAb/ ELISA system. All those patients (9) was found to have an egg count below 50 epg feces (patients with light infections). ROC curve analyses revealed that sandwich ELISA using gold-MAb was an excellent diagnostic investigator that could differentiate Schistosoma patients from healthy controls, on the other hand it revealed that sandwich ELISA using MAb was not accurate enough as it could not recognize nine out of 71 patients with light infections. Conclusion Our data demonstrated that: Loading gold nanoparticles with MAb (6D/6F) increases the sensitivity and specificity of sandwich ELISA for detection of CSA, thus active (early) and light infections could be easily detected. Moreover this binding will decrease the amount of MAb consumed in the assay and lower the coast. The significant positive correlation that was detected between ova count (intensity of infection) and OD reading in sandwich ELISA using gold- MAb enables its use to detect the severity of infections and follow up patients after treatment for monitoring of cure.

Keywords: Schistosomiasis, nanoparticles, gold, monoclonal antibodies, ELISA

Procedia PDF Downloads 371
2452 Turbine Engine Performance Experimental Tests of Subscale UAV

Authors: Haluk Altay, Bilal Yücel, Berkcan Ulcay, Yücel Aydın

Abstract:

In this study, the design, integration, and testing of measurement systems required for performance tests of jet engines used in small-scale unmanned aerial vehicles are described. Performance tests are carried out as thrust and fuel consumption. For thrust tests, measurements are made using a load cell. Amplifier and filter designs have been made for the load cell to measure accurately to meet the desired sensitivity. It was calibrated by making multiple measurements at different thrust levels. As a result of these processes, the cycle thrust graph was obtained. For fuel consumption tests, tests are carried out using a flow meter. Performance graphics were obtained by finding the fuel consumption for different RPM levels of the engine.

Keywords: jet engine, UAV, experimental test, loadcell, thrust, fuel consumption

Procedia PDF Downloads 80
2451 Nanocrystalline Na0.1V2O5.nH2Oxerogel Thin Film for Gas Sensing

Authors: M. S. Al-Assiri, M. M. El-Desoky, A. A. Bahgat

Abstract:

Nanocrystalline thin film of Na0.1V2O5.nH2O xerogel obtained by sol-gel synthesis was used as a gas sensor. Gas sensing properties of different gases such as hydrogen, petroleum and humidity were investigated. Applying XRD and TEM the size of the nanocrystals is found to be 7.5 nm. SEM shows a highly porous structure with submicron meter-sized voids present throughout the sample. FTIR measurement shows different chemical groups identifying the obtained series of gels. The sample was n-type semiconductor according to the thermoelectric power and electrical conductivity. It can be seen that the sensor response curves from 130°C to 150°C show a rapid increase in sensitivity for all types of gas injection, low response values for heating period and the rapid high response values for cooling period. This result may suggest that this material is able to act as gas sensor during the heating and cooling process.

Keywords: sol-gel, thermoelectric power, XRD, TEM, gas sensing

Procedia PDF Downloads 303
2450 Quantum Conductance Based Mechanical Sensors Fabricated with Closely Spaced Metallic Nanoparticle Arrays

Authors: Min Han, Di Wu, Lin Yuan, Fei Liu

Abstract:

Mechanical sensors have undergone a continuous evolution and have become an important part of many industries, ranging from manufacturing to process, chemicals, machinery, health-care, environmental monitoring, automotive, avionics, and household appliances. Concurrently, the microelectronics and microfabrication technology have provided us with the means of producing mechanical microsensors characterized by high sensitivity, small size, integrated electronics, on board calibration, and low cost. Here we report a new kind of mechanical sensors based on the quantum transport process of electrons in the closely spaced nanoparticle films covering a flexible polymer sheet. The nanoparticle films were fabricated by gas phase depositing of preformed metal nanoparticles with a controlled coverage on the electrodes. To amplify the conductance of the nanoparticle array, we fabricated silver interdigital electrodes on polyethylene terephthalate(PET) by mask evaporation deposition. The gaps of the electrodes ranged from 3 to 30μm. Metal nanoparticles were generated from a magnetron plasma gas aggregation cluster source and deposited on the interdigital electrodes. Closely spaced nanoparticle arrays with different coverage could be gained through real-time monitoring the conductance. In the film coulomb blockade and quantum, tunneling/hopping dominate the electronic conduction mechanism. The basic principle of the mechanical sensors relies on the mechanical deformation of the fabricated devices which are translated into electrical signals. Several kinds of sensing devices have been explored. As a strain sensor, the device showed a high sensitivity as well as a very wide dynamic range. A gauge factor as large as 100 or more was demonstrated, which can be at least one order of magnitude higher than that of the conventional metal foil gauges or even better than that of the semiconductor-based gauges with a workable maximum applied strain beyond 3%. And the strain sensors have a workable maximum applied strain larger than 3%. They provide the potential to be a new generation of strain sensors with performance superior to that of the currently existing strain sensors including metallic strain gauges and semiconductor strain gauges. When integrated into a pressure gauge, the devices demonstrated the ability to measure tiny pressure change as small as 20Pa near the atmospheric pressure. Quantitative vibration measurements were realized on a free-standing cantilever structure fabricated with closely-spaced nanoparticle array sensing element. What is more, the mechanical sensor elements can be easily scaled down, which is feasible for MEMS and NEMS applications.

Keywords: gas phase deposition, mechanical sensors, metallic nanoparticle arrays, quantum conductance

Procedia PDF Downloads 274
2449 Techno-Economic Analysis of 1,3-Butadiene and ε-Caprolactam Production from C6 Sugars

Authors: Iris Vural Gursel, Jonathan Moncada, Ernst Worrell, Andrea Ramirez

Abstract:

In order to achieve the transition from a fossil to bio-based economy, biomass needs to replace fossil resources in meeting the world’s energy and chemical needs. This calls for development of biorefinery systems allowing cost-efficient conversion of biomass to chemicals. In biorefinery systems, feedstock is converted to key intermediates called platforms which are converted to wide range of marketable products. The C6 sugars platform stands out due to its unique versatility as precursor for multiple valuable products. Among the different potential routes from C6 sugars to bio-based chemicals, 1,3-butadiene and ε-caprolactam appear to be of great interest. Butadiene is an important chemical for the production of synthetic rubbers, while caprolactam is used in production of nylon-6. In this study, ex-ante techno-economic performance of 1,3-butadiene and ε-caprolactam routes from C6 sugars were assessed. The aim is to provide insight from an early stage of development into the potential of these new technologies, and the bottlenecks and key cost-drivers. Two cases for each product line were analyzed to take into consideration the effect of possible changes on the overall performance of both butadiene and caprolactam production. Conceptual process design for the processes was developed using Aspen Plus based on currently available data from laboratory experiments. Then, operating and capital costs were estimated and an economic assessment was carried out using Net Present Value (NPV) as indicator. Finally, sensitivity analyses on processing capacity and prices was done to take into account possible variations. Results indicate that both processes perform similarly from an energy intensity point of view ranging between 34-50 MJ per kg of main product. However, in terms of processing yield (kg of product per kg of C6 sugar), caprolactam shows higher yield by a factor 1.6-3.6 compared to butadiene. For butadiene production, with the economic parameters used in this study, for both cases studied, a negative NPV (-642 and -647 M€) was attained indicating economic infeasibility. For the caprolactam production, one of the cases also showed economic infeasibility (-229 M€), but the case with the higher caprolactam yield resulted in a positive NPV (67 M€). Sensitivity analysis indicated that the economic performance of caprolactam production can be improved with the increase in capacity (higher C6 sugars intake) reflecting benefits of the economies of scale. Furthermore, humins valorization for heat and power production was considered and found to have a positive effect. Butadiene production was found sensitive to the price of feedstock C6 sugars and product butadiene. However, even at 100% variation of the two parameters, butadiene production remained economically infeasible. Overall, the caprolactam production line shows higher economic potential in comparison to that of butadiene. The results are useful in guiding experimental research and providing direction for further development of bio-based chemicals.

Keywords: bio-based chemicals, biorefinery, C6 sugars, economic analysis, process modelling

Procedia PDF Downloads 152
2448 Performance Evaluation of Contemporary Classifiers for Automatic Detection of Epileptic EEG

Authors: K. E. Ch. Vidyasagar, M. Moghavvemi, T. S. S. T. Prabhat

Abstract:

Epilepsy is a global problem, and with seizures eluding even the smartest of diagnoses a requirement for automatic detection of the same using electroencephalogram (EEG) would have a huge impact in diagnosis of the disorder. Among a multitude of methods for automatic epilepsy detection, one should find the best method out, based on accuracy, for classification. This paper reasons out, and rationalizes, the best methods for classification. Accuracy is based on the classifier, and thus this paper discusses classifiers like quadratic discriminant analysis (QDA), classification and regression tree (CART), support vector machine (SVM), naive Bayes classifier (NBC), linear discriminant analysis (LDA), K-nearest neighbor (KNN) and artificial neural networks (ANN). Results show that ANN is the most accurate of all the above stated classifiers with 97.7% accuracy, 97.25% specificity and 98.28% sensitivity in its merit. This is followed closely by SVM with 1% variation in result. These results would certainly help researchers choose the best classifier for detection of epilepsy.

Keywords: classification, seizure, KNN, SVM, LDA, ANN, epilepsy

Procedia PDF Downloads 520
2447 Dissimilar Cu/Al Friction Stir Welding: Sensitivity of the Tool Offset

Authors: Tran Hung Tra, Hao Dinh Duong, Masakazu Okazaki

Abstract:

Copper 1100 and aluminum 1050 plates with a thickness of 5.0 mm are butt-joint using friction stir welding. The tool offset is linearly varied along the welding path. Two welding regimes, using the same linear tool offset but in opposite directions, are applied for fabricating two Cu/Al plates. The material flow is dominated by both tool offset and offset history. The intermetallic compounds layer and interface morphology in each welded plate are formed in a different manner. As a result, the bonding strength and fracture behavior between two welded plates are significantly distinct. The role of interface morphology on fracture behavior is analyzed by the finite element method.

Keywords: Cu/Al dissimilar welding, offset history, interface morphology, intermetallic compounds, strength and fracture

Procedia PDF Downloads 76
2446 A Systematic Review Of Literature On The Importance Of Cultural Humility In Providing Optimal Palliative Care For All Persons

Authors: Roseanne Sharon Borromeo, Mariana Carvalho, Mariia Karizhenskaia

Abstract:

Healthcare providers need to comprehend cultural diversity for optimal patient-centered care, especially near the end of life. Although a universal method for navigating cultural differences would be ideal, culture’s high complexity makes this strategy impossible. Adding cultural humility, a process of self-reflection to understand personal and systemic biases and humbly acknowledging oneself as a learner when it comes to understanding another's experience leads to a meaningful process in palliative care generating respectful, honest, and trustworthy relationships. This study is a systematic review of the literature on cultural humility in palliative care research and best practices. Race, religion, language, values, and beliefs can affect an individual’s access to palliative care, underscoring the importance of culture in palliative care. Cultural influences affect end-of-life care perceptions, impacting bereavement rituals, decision-making, and attitudes toward death. Cultural factors affecting the delivery of care identified in a scoping review of Canadian literature include cultural competency, cultural sensitivity, and cultural accessibility. As the different parts of the world become exponentially diverse and multicultural, healthcare providers have been encouraged to give culturally competent care at the bedside. Therefore, many organizations have made cultural competence training required to expose professionals to the special needs and vulnerability of diverse populations. Cultural competence is easily standardized, taught, and implemented; however, this theoretically finite form of knowledge can dangerously lead to false assumptions or stereotyping, generating poor communication, loss of bonds and trust, and poor healthcare provider-patient relationship. In contrast, Cultural humility is a dynamic process that includes self-reflection, personal critique, and growth, allowing healthcare providers to respond to these differences with an open mind, curiosity, and awareness that one is never truly a “cultural” expert and requires life-long learning to overcome common biases and ingrained societal influences. Cultural humility concepts include self-awareness and power imbalances. While being culturally competent requires being skilled and knowledgeable in one’s culture, being culturally humble involves the sometimes-uncomfortable position of healthcare providers as students of the patient. Incorporating cultural humility emphasizes the need to approach end-of-life care with openness and responsiveness to various cultural perspectives. Thus, healthcare workers need to embrace lifelong learning in individual beliefs and values on suffering, death, and dying. There have been different approaches to this as well. Some adopt strategies for cultural humility, addressing conflicts and challenges through relational and health system approaches. In practice and research, clinicians and researchers must embrace cultural humility to advance palliative care practices, using qualitative methods to capture culturally nuanced experiences. Cultural diversity significantly impacts patient-centered care, particularly in end-of-life contexts. Cultural factors also shape end-of-life perceptions, impacting rituals, decision-making, and attitudes toward death. Cultural humility encourages openness and acknowledges the limitations of expertise in one’s culture. A consistent self-awareness and a desire to understand patients’ beliefs drive the practice of cultural humility. This dynamic process requires practitioners to learn continuously, fostering empathy and understanding. Cultural humility enhances palliative care, ensuring it resonates genuinely across cultural backgrounds and enriches patient-provider interactions.

Keywords: cultural competency, cultural diversity, cultural humility, palliative care, self-awareness

Procedia PDF Downloads 62
2445 The First Step to Standardization of Iranian Buffalo Milk: Physicochemical Characterization

Authors: Farnoosh Attar

Abstract:

Nowadays, buffalo’s milk due to has highly nutritional properties, has a special place among consumers and its application for the production of dairy products due to the high technological properties is increasing day by day. In the present study, the physicochemical characteristics of Iranian buffalo’s milk were compared with cow's milk. According to chemical analysis, the amount of fat, protein, and total solid was higher in buffalo milk than cow's milk (respectively, 8.2%, 4.73%, and 15.92% compared with 3.5%, 3.25%, and 12.5%). Also, the percentage of cholesterol buffalo’s milk was less than in cow's milk. In contrast, no significant difference between the pH, acidity, and specific gravity was observed. The size of buffalo milk fat globules was larger than cow's milk. In addition, the profile of buffalo free fatty acids milk showed the relatively high distribution of long chain saturated fatty acids. The presence of four major bands related to αs casein, β casein, β-lactoglobulin, and α-lactalbumin with quite higher intensity than cow’s milk was also observed. The results obtained will provide a reference investigation to improve the developing of buffalo milk standard.

Keywords: buffalo milk, physicochemical characterization, standardization, dairy products

Procedia PDF Downloads 443
2444 The Effect of Nylon and Kevlar Stitching on the Mode I Fracture of Carbon/Epoxy Composites

Authors: Nisrin R. Abdelal, Steven L. Donaldson

Abstract:

Composite materials are widely used in aviation industry due to their superior properties; however, they are susceptible to delamination. Through-thickness stitching is one of the techniques to alleviate delamination. Kevlar is one of the most common stitching materials; in contrast, it is expensive and presents stitching fabrication challenges. Therefore, this study compares the performance of Kevlar with an inexpensive and easy-to-use nylon fiber in stitching to alleviate delamination. Three laminates of unidirectional carbon fiber-epoxy composites were manufactured using vacuum assisted resin transfer molding process. One panel was stitched with Kevlar, one with nylon, and one unstitched. Mode I interlaminar fracture tests were carried out on specimens from the three composite laminates, and the results were compared. Fractographic analysis using optical and scanning electron microscope were conducted to reveal the differences between stitching with Kevlar and nylon on the internal microstructure of the composite with respect to the interlaminar fracture toughness values.

Keywords: carbon, delamination, Kevlar, mode I, nylon, stitching

Procedia PDF Downloads 287
2443 A Mathematical Optimization Model for Locating and Fortifying Capacitated Warehouses under Risk of Failure

Authors: Tareq Oshan

Abstract:

Facility location and size decisions are important to any company because they affect profitability and success. However, warehouses are exposed to various risks of failure that affect their activity. This paper presents a mixed-integer non-linear mathematical model that can be used to determine optimal warehouse locations and sizes, which warehouses to fortify, and which branches should be assigned to specific warehouses when there is a risk of warehouse failure. Every branch is assigned to a fortified primary warehouse or a nonfortified primary warehouse and a fortified backup warehouse. The standard method and an introduced method, based on the average probabilities, for linearizing this mathematical model were used. A Canadian case study was used to demonstrate the developed mathematical model, followed by some sensitivity analysis.

Keywords: supply chain network design, fortified warehouse, mixed-integer mathematical model, warehouse failure risk

Procedia PDF Downloads 243
2442 Study on Co-Relation of Prostate Specific Antigen with Metastatic Bone Disease in Prostate Cancer on Skeletal Scintigraphy

Authors: Muhammad Waleed Asfandyar, Akhtar Ahmed, Syed Adib-ul-Hasan Rizvi

Abstract:

Objective: To evaluate the ability of serum concentration of prostate specific antigen between two cutting points considering it as a predictor of skeletal metastasis on bone scintigraphy in men with prostate cancer. Settings: This study was carried out in department of Nuclear Medicine at Sindh Institute of Urology and Transplantation (SIUT) Karachi, Pakistan. Materials and Method: From August 2013 to November 2013, forty two (42) consecutive patients with prostate cancer who underwent technetium-99m methylene diphosphonate (Tc-99mMDP) whole body bone scintigraphy were prospectively analyzed. The information was collected from the scintigraphic database at a Nuclear medicine department Sindh institute of urology and transplantation Karachi Pakistan. Patients who did not have a serum PSA concentration available within 1 month before or after the time of performing the Tc-99m MDP whole body bone scintigraphy were excluded from this study. A whole body bone scintigraphy scan (from the toes to top of the head) was performed using a whole-body Moving gamma camera technique (anterior and posterior) 2–4 hours after intravenous injection of 20 mCi of Tc-99m MDP. In addition, all patients necessarily have a pathological report available. Bony metastases were determined from the bone scan studies and no further correlation with histopathology or other imaging modalities were performed. To preserve patient confidentiality, direct patient identifiers were not collected. In all the patients, Prostate specific antigen values and skeletal scintigraphy were evaluated. Results: The mean age, mean PSA, and incidence of bone metastasis on bone scintigraphy were 68.35 years, 370.51 ng/mL and 19/42 (45.23%) respectively. According to PSA levels, patients were divided into 5 groups < 10ng/mL (10/42), 10-20 ng/mL (5/42), 20-50 ng/mL (2/42), 50-100 (3/42), 100- 500ng/mL (3/42) and more than 500ng/mL (0/42) presenting negative bone scan. The incidence of positive bone scan (%) for bone metastasis for each group were O1 patient (5.26%), 0%, 03 patients (15.78%), 01 patient (5.26%), 04 patients (21.05%), and 10 patients (52.63%) respectively. From the 42 patients 19 (45.23%) presented positive scintigraphic examination for the presence of bone metastasis. 1 patient presented bone metastasis on bone scintigraphy having PSA level less than 10ng/mL, and in only 1 patient (5.26%) with bone metastasis PSA concentration was less than 20 ng/mL. therefore, when the cutting point adopted for PSA serum concentration was 10ng/mL, a negative predictive value for bone metastasis was 95% with sensitivity rates 94.74% and the positive predictive value and specificities of the method were 56.53% and 43.48% respectively. When the cutting point of PSA serum concentration was 20ng/mL the observed results for Positive predictive value and specificity were (78.27% and 65.22% respectively) whereas negative predictive value and sensitivity stood (100% and 95%) respectively. Conclusion: Results of our study allow us to conclude that serum PSA concentration of higher than 20ng/mL was the most accurate cutting point than a serum concentration of PSA higher than 10ng/mL to predict metastasis in radionuclide bone scintigraphy. In this way, unnecessary cost can be avoided, since a considerable part of prostate adenocarcinomas present low serum PSA levels less than 20 ng/mL and for these cases radionuclide bone scintigraphy could be unnecessary.

Keywords: bone scan, cut off value, prostate specific antigen value, scintigraphy

Procedia PDF Downloads 319
2441 Interferometric Demodulation Scheme Using a Mode-Locker Fiber Laser

Authors: Liang Zhang, Yuanfu Lu, Yuming Dong, Guohua Jiao, Wei Chen, Jiancheng Lv

Abstract:

We demonstrated an interferometric demodulation scheme using a mode-locked fiber laser. The mode-locked fiber laser is launched into a two-beam interferometer. When the ratio between the fiber path imbalance of interferometer and the laser cavity length is close to an integer, an interferometric fringe emerges as a result of vernier effect, and then the phase shift of the interferometer can be demodulated. The mode-locked fiber laser provides a large bandwidth and reduces the cost for wavelength division multiplexion (WDM). The proposed interferometric demodulation scheme can be further applied in multi-point sensing system such as fiber optics hydrophone array, seismic wave detection network with high sensitivity and low cost.

Keywords: fiber sensing, interferometric demodulation, mode-locked fiber laser, vernier effect

Procedia PDF Downloads 329
2440 Effect of Irradiation on Nano-Indentation Properties and Microstructure of X-750 Ni-Based Superalloy

Authors: Pooyan Changizian, Zhongwen Yao

Abstract:

The purpose of current study is to make an excellent correlation between mechanical properties and microstructures of ion irradiated X-750 Ni-based superalloy. Towards this end, two different irradiation procedures were carried out, including single Ni ion irradiation and pre-helium implantation with subsequent Ni ion irradiation. Nano-indentation technique was employed to evaluate the mechanical properties of irradiated material. The nano-hardness measurements depict highly different results for two irradiation procedures. Single ion irradiated X-750 shows softening behavior; however, pre-helium implanted specimens present significant hardening compared to the un-irradiated material. Cross-section TEM examination demonstrates that softening is attributed to the γ׳-precipitate instability (disordering/dissolution) which overcomes the hardening effect of irradiation-induced defects. In contrast, the presence of cavities or helium bubbles is probably the main cause for irradiation-induced hardening of helium implanted samples.

Keywords: Inconel X-750, nanoindentation, helium bubbles, defects

Procedia PDF Downloads 222
2439 Laser Ultrasonic Diagnostics and Acoustic Emission Technique for Examination of Rock Specimens under Uniaxial Compression

Authors: Elena B. Cherepetskaya, Vladimir A. Makarov, Dmitry V. Morozov, Ivan E. Sas

Abstract:

Laboratory studies of the stress-strain behavior of rocks specimens were conducted by using acoustic emission and laser-ultrasonic diagnostics. The sensitivity of the techniques allowed changes in the internal structure of the specimens under uniaxial compressive load to be examined at micro- and macro scales. It was shown that microcracks appear in geologic materials when the stress level reaches about 50% of breaking strength. Also, the characteristic stress of the main crack formation was registered in the process of single-stage compression of rocks. On the base of laser-ultrasonic echoscopy, 2D visualization of the internal structure of rocky soil specimens was realized, and the microcracks arising during uniaxial compression were registered.

Keywords: acoustic emission, geomaterial, laser ultrasound, uniaxial compression

Procedia PDF Downloads 375
2438 Characterization of the MOSkin Dosimeter for Accumulated Dose Assessment in Computed Tomography

Authors: Lenon M. Pereira, Helen J. Khoury, Marcos E. A. Andrade, Dean L. Cutajar, Vinicius S. M. Barros, Anatoly B. Rozenfeld

Abstract:

With the increase of beam widths and the advent of multiple-slice and helical scanners, concerns related to the current dose measurement protocols and instrumentation in computed tomography (CT) have arisen. The current methodology of dose evaluation, which is based on the measurement of the integral of a single slice dose profile using a 100 mm long cylinder ionization chamber (Ca,100 and CPPMA, 100), has been shown to be inadequate for wide beams as it does not collect enough of the scatter-tails to make an accurate measurement. In addition, a long ionization chamber does not offer a good representation of the dose profile when tube current modulation is used. An alternative approach has been suggested by translating smaller detectors through the beam plane and assessing the accumulated dose trough the integral of the dose profile, which can be done for any arbitrary length in phantoms or in the air. For this purpose, a MOSFET dosimeter of small dosimetric volume was used. One of its recently designed versions is known as the MOSkin, which is developed by the Centre for Medical Radiation Physics at the University of Wollongong, and measures the radiation dose at a water equivalent depth of 0.07 mm, allowing the evaluation of skin dose when placed at the surface, or internal point doses when placed within a phantom. Thus, the aim of this research was to characterize the response of the MOSkin dosimeter for X-ray CT beams and to evaluate its application for the accumulated dose assessment. Initially, tests using an industrial x-ray unit were carried out at the Laboratory of Ionization Radiation Metrology (LMRI) of Federal University of Pernambuco, in order to investigate the sensitivity, energy dependence, angular dependence, and reproducibility of the dose response for the device for the standard radiation qualities RQT 8, RQT 9 and RQT 10. Finally, the MOSkin was used for the accumulated dose evaluation of scans using a Philips Brilliance 6 CT unit, with comparisons made between the CPPMA,100 value assessed with a pencil ionization chamber (PTW Freiburg TW 30009). Both dosimeters were placed in the center of a PMMA head phantom (diameter of 16 cm) and exposed in the axial mode with collimation of 9 mm, 250 mAs and 120 kV. The results have shown that the MOSkin response was linear with doses in the CT range and reproducible (98.52%). The sensitivity for a single MOSkin in mV/cGy was as follows: 9.208, 7.691 and 6.723 for the RQT 8, RQT 9 and RQT 10 beams qualities respectively. The energy dependence varied up to a factor of ±1.19 among those energies and angular dependence was not greater than 7.78% within the angle range from 0 to 90 degrees. The accumulated dose and the CPMMA, 100 value were 3,97 and 3,79 cGy respectively, which were statistically equivalent within the 95% confidence level. The MOSkin was shown to be a good alternative for CT dose profile measurements and more than adequate to provide accumulated dose assessments for CT procedures.

Keywords: computed tomography dosimetry, MOSFET, MOSkin, semiconductor dosimetry

Procedia PDF Downloads 311
2437 Fighting COVID-19: Lessons and Experience from the World’s Largest Economies

Authors: Xiaowen Zhang, Wanda Luen-Wun Siu

Abstract:

The paper reviews the insights gained in combating COVID-19 in the US, Japan, and China. After evaluation and investigation, we found that China’s and Japan’s experience of fighting COVID-19 is commendable. The Chinese government and the Japanese administration have implemented highly effective governance and public health course of action to fight COVID-19. Government-led epidemic control with a staunch belief in science can roll out effective pandemic control strategies. In contrast, the US failed to react to COVID-19 effectively. The relaxed public health measures of ending shutdowns prematurely were not working. When the US keeps business open after the spring shutdown, COVID-19 cases are soaring. Such experiences inform us effective governance and a mandatory and stricter approach can better curb a pandemic than milder measures in handling a public health emergency. And China and Japan, where collectivistic culture reins, can better maneuver a public health crisis with collective efforts.

Keywords: US, China, Japan, COVID-19

Procedia PDF Downloads 191
2436 Multimodal Ophthalmologic Evaluation Can Detect Retinal Injuries in Asymptomatic Patients With Primary Antiphospholipid Syndrome

Authors: Taurino S. R. Neto, Epitácio D. S. Neto, Flávio Signorelli, Gustavo G. M. Balbi, Alex H. Higashi, Mário Luiz R. Monteiro, Eloisa Bonfá, Danieli C. O. Andrade, Leandro C. Zacharias

Abstract:

Purpose: To perform a multimodal evaluation, including the use of Optical Coherence Angiotomography (OCTA), in patients with primary antiphospholipid syndrome (PAPS) without ocular complaints and to compare them with healthy individuals. Methods: A complete structural and functional ophthalmological evaluation using OCTA and microperimetry (MP) exam in patients with PAPS, followed at a tertiary rheumatology outpatient clinic, was performed. All ophthalmologic manifestations were recorded and then statistical analysis was performed for comparative purposes; p <0.05 was considered statistically significant. Results: 104 eyes of 52 subjects (26 patients with PAPS without ocular complaints and 26 healthy individuals) were included. Among PAPS patients, 21 were female (80.8%) and 21 (80.8%) were Caucasians. Thrombotic PAPS was the main clinical criteria manifestation (100%); 65.4% had venous and 34.6% had arterial thrombosis. Obstetrical criteria were present in 34.6% of all thrombotic PAPS patients. Lupus anticoagulant was present in all patients. 19.2% of PAPS patients presented ophthalmologic findings against none of the healthy individuals. The most common retinal change was paracentral acute middle maculopathy (PAMM) (3 patients, 5 eyes), followed by drusen-like deposits (1 patient, 2 eyes) and pachychoroid pigment epitheliopathy (1 patient, 1 eye). Systemic hypertension and hyperlipidaemia were present in 100% of the PAPS patients with PAMM, while only six patients (26.1%) with PAPS without PAMM presented these two risk factors together. In the quantitative OCTA evaluation, we found significant differences between PAPS patients and controls in both the superficial vascular complex (SVC) and deep vascular complex (DVC) in the high-speed protocol, as well as in the SVC in the high-resolution protocol. In the analysis of the foveal avascular zone (FAZ) parameters, the PAPS group had a larger area of FAZ in the DVC using the high-speed method compared to the control group (p=0.047). In the quantitative analysis of the MP, the PAPS group had lower central (p=0.041) and global (p<0.001) retinal sensitivity compared to the control group, as well as in the sector analysis, with the exception of the inferior sector. In the quantitative evaluation of fixation stability, there was a trend towards worse stability in the PAPS subgroup with PAMM in both studied methods. Conclusions: PAMM was observed in 11.5% of PAPS patients with no previous ocular complaints. Systemic hypertension concomitant with hyperlipidemia was the most commonly associated risk factor for PAMM in patients with PAPS. PAPS patients present lower vascular density and retinal sensitivity compared to the control group, even in patients without PAMM.

Keywords: antiphospholipid syndrome, optical coherence angio tomography, optical coherence tomography, retina

Procedia PDF Downloads 80
2435 Determination of the Botanical Origin of Honey by the Artificial Neural Network Processing of PARAFAC Scores of Fluorescence Data

Authors: Lea Lenhardt, Ivana Zeković, Tatjana Dramićanin, Miroslav D. Dramićanin

Abstract:

Fluorescence spectroscopy coupled with parallel factor analysis (PARAFAC) and artificial neural networks (ANN) were used for characterization and classification of honey. Excitation emission spectra were obtained for 95 honey samples of different botanical origin (acacia, sunflower, linden, meadow, and fake honey) by recording emission from 270 to 640 nm with excitation in the range of 240-500 nm. Fluorescence spectra were described with a six-component PARAFAC model, and PARAFAC scores were further processed with two types of ANN’s (feed-forward network and self-organizing maps) to obtain algorithms for classification of honey on the basis of their botanical origin. Both ANN’s detected fake honey samples with 100% sensitivity and specificity.

Keywords: honey, fluorescence, PARAFAC, artificial neural networks

Procedia PDF Downloads 954
2434 New Dynamic Constitutive Model for OFHC Copper Film

Authors: Jin Sung Kim, Hoon Huh

Abstract:

The material properties of OFHC copper film was investigated with the High-Speed Material Micro Testing Machine (HSMMTM) at the high strain rates. The rate-dependent stress-strain curves from the experiment and the Johnson-Cook curve fitting showed large discrepancies as the plastic strain increases since the constitutive model implies no rate-dependent strain hardening effect. A new constitutive model was proposed in consideration of rate-dependent strain hardening effect. The strain rate hardening term in the new constitutive model consists of the strain rate sensitivity coefficients of the yield strength and strain hardening.

Keywords: rate dependent material properties, dynamic constitutive model, OFHC copper film, strain rate

Procedia PDF Downloads 486