Search results for: resonant column test
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 9960

Search results for: resonant column test

9210 Enhancement of Raman Scattering using Photonic Nanojet and Whispering Gallery Mode of a Dielectric Microstructure

Authors: A. Arya, R. Laha, V. R. Dantham

Abstract:

We report the enhancement of Raman scattering signal by one order of magnitude using photonic nanojet (PNJ) of a lollipop shaped dielectric microstructure (LSDM) fabricated by a pulsed CO₂ laser. Here, the PNJ is generated by illuminating sphere portion of the LSDM with non-resonant laser. Unlike the surface enhanced Raman scattering (SERS) technique, this technique is simple, and the obtained results are highly reproducible. In addition, an efficient technique is proposed to enhance the SERS signal with the help of high quality factor optical resonance (whispering gallery mode) of a LSDM. From the theoretical simulations, it has been found that at least an order of magnitude enhancement in the SERS signal could be achieved easily using the proposed technique. We strongly believe that this report will enable the research community for improving the Raman scattering signals.

Keywords: localized surface plasmons, photonic nanojet, SERS, whispering gallery mode

Procedia PDF Downloads 246
9209 Analytical Response Characterization of High Mobility Transistor Channels

Authors: F. Z. Mahi, H. Marinchio, C. Palermo, L. Varani

Abstract:

We propose an analytical approach for the admittance response calculation of the high mobility InGaAs channel transistors. The development of the small-signal admittance takes into account the longitudinal and transverse electric fields through a pseudo two-dimensional approximation of the Poisson equation. The total currents and the potentials matrix relation between the gate and the drain terminals determine the frequency-dependent small-signal admittance response. The analytical results show that the admittance spectrum exhibits a series of resonant peaks corresponding to the excitation of plasma waves. The appearance of the resonance is discussed and analyzed as functions of the channel length and the temperature. The model can be used, on one hand, to control the appearance of plasma resonances, and on the other hand, can give significant information about the admittance phase frequency dependence.

Keywords: small-signal admittance, Poisson equation, currents and potentials matrix, the drain and the gate terminals, analytical model

Procedia PDF Downloads 540
9208 Experimental Study of Different Types of Concrete in Uniaxial Compression Test

Authors: Khashayar Jafari, Mostafa Jafarian Abyaneh, Vahab Toufigh

Abstract:

Polymer concrete (PC) is a distinct concrete with superior characteristics in comparison to ordinary cement concrete. It has become well-known for its applications in thin overlays, floors and precast components. In this investigation, the mechanical properties of PC with different epoxy resin contents, ordinary cement concrete (OCC) and lightweight concrete (LC) have been studied under uniaxial compression test. The study involves five types of concrete, with each type being tested four times. Their complete elastic-plastic behavior was compared with each other through the measurement of volumetric strain during the tests. According to the results, PC showed higher strength, ductility and energy absorption with respect to OCC and LC.

Keywords: polymer concrete, ordinary cement concrete, lightweight concrete, uniaxial compression test, volumetric strain

Procedia PDF Downloads 394
9207 A Change in Psychological Child Development Case Study on Animation Film Tom and Jerry

Authors: Shani Ruri Efendi, Lucky Tio Monika, Prita Esita

Abstract:

Purpose: The purpose of this paper is to know the negative impact of the animated film show Tom & Jerry, how it might affect the changes of psychological child development, if this affects the development growth of children's behaviour and advice from the case of psychology as a solution to such problems Design/methodology/approach: The paper’s findings are based on an experimental method in conducting the test. The experiment lasted for 6 days at elementary school children aged from 6-7 years. Findings: The results of the analysis can be found that pictorial questionnaire which is one of the test tools in the study had no significant effect and also using IQ test is one test tool in the study of positive and significant influence of television has changed the way of thinking in children. Originality/value: This research tries to dig more into the negative influence of animated film Tom and Jerry as a negative influence on the development of children who may have the implementation of the child's behaviour in life.

Keywords: child development, animated film, Tom and Jerry, elementary school children

Procedia PDF Downloads 766
9206 Evaluation of the End Effect Impact on the Torsion Test for Determining the Shear Modulus of a Timber Beam through a Photogrammetry Approach

Authors: Niaz Gharavi, Hexin Zhang, Yanjun Xie

Abstract:

The timber beam end effect in the torsion test is evaluated using binocular stereo vision system. It is recommended by BS EN 408:2010+A1:2012 to exclude a distance of two to three times of cross-sectional thickness (b) from ends to avoid the end effect; whereas, this study indicates that this distance is not sufficiently far enough to remove this effect in slender cross-sections. The shear modulus of six timber beams with different aspect ratios is determined at the various angles and cross-sections. The result of this experiment shows that the end affected span of each specimen varies depending on their aspect ratios. It is concluded that by increasing the aspect ratio this span will increase. However, by increasing the distance from the ends to the values greater than 6b, the shear modulus trend becomes constant and end effect will be negligible. Moreover, it is concluded that end affected span is preferred to be depth-dependent rather than thickness-dependant.

Keywords: end clamp effect, full-size timber test, shear properties, torsion test, wood engineering

Procedia PDF Downloads 282
9205 Effects of Static Stretching Exercises on Flexibility and Sprint Performance in Inactive Healthy Girls

Authors: Gulsun Guven

Abstract:

The aim of this study was to examine the acute effects of static stretching exercises on the flexibility and sprint performance in 10-12 years old inactive healthy girls. A total of 27 girls were randomly divided into control group (n=15) and stretching group (n=12) who performed static stretching. Sit and reach flexibility and 30-meter sprint pre-tests were performed for both groups. Static stretching exercises were performed three times, 30 sec. practice and 15 sec. rest for each leg only on five muscle by stretching group. The post-tests were performed in five minutes after static stretching exercise. Paired t-test was used to analyze differentiations among the group parameters. According to research results, there is a significant difference between pre-test and post-test flexibility (p < 0.05) and sprint test results (p < 0.01). As a conclusion of the study, static stretching exercises improve flexibility but decrease sprint performance in 10-12 years old inactive healthy girls.

Keywords: flexibility, inactive girl, sprint, static stretching

Procedia PDF Downloads 221
9204 The Students' Mathematical Competency and Attitude towards Mathematics Using the Trachtenberg Speed Math System

Authors: Marlone D. Severo

Abstract:

A pre- and post-test quasi-experimental design was used to test the intervention of Trachtenberg Speed Math on the mathematical competency of sixty (60) matched-paired students with a poor performing grade in Mathematics from one of the biggest public national high school at the South of Metro Manila. Both control and experimental group were administered with the Attitude Towards Mathematics Inventory (ATMI) before the pretest were given and both group showed high dislike for Mathematics. Pretest showed a 53 percent accuracy for the control group and 51 percent for the experimental group using a 15-item long multiplication test without any aid of a computing device. The experimental group were taught how to use the Trachtenberg number-keys and techniques in multiplication between October 2014 to March 2015. Post-test showed an improvement in the experimental group with 96 percent accuracy for the control group and a dismal 57 percent for the control group in long-multiplication. Post-test ATMI were administered. The control group showed a great dislike towards Mathematics, while the experimental group showed a positive attitude towards the subject.

Keywords: attitude towards mathematics, mathematical competency, number-keys, trachtenberg speed math

Procedia PDF Downloads 367
9203 Design of Compact Dual-Band Planar Antenna for WLAN Systems

Authors: Anil Kumar Pandey

Abstract:

A compact planar monopole antenna with dual-band operation suitable for wireless local area network (WLAN) application is presented in this paper. The antenna occupies an overall area of 18 ×12 mm2. The antenna is fed by a coplanar waveguide (CPW) transmission line and it combines two folded strips, which radiates at 2.4 and 5.2 GHz. In the proposed antenna, by optimally selecting the antenna dimensions, dual-band resonant modes with a much wider impedance matching at the higher band can be produced. Prototypes of the obtained optimized design have been simulated using EM solver. The simulated results explore good dual-band operation with -10 dB impedance bandwidths of 50 MHz and 2400 MHz at bands of 2.4 and 5.2 GHz, respectively, which cover the 2.4/5.2/5.8 GHz WLAN operating bands. Good antenna performances such as radiation patterns and antenna gains over the operating bands have also been observed. The antenna with a compact size of 18×12×1.6 mm3 is designed on an FR4 substrate with a dielectric constant of 4.4.

Keywords: CPW antenna, dual-band, electromagnetic simulation, wireless local area network (WLAN)

Procedia PDF Downloads 209
9202 Using Metacognitive Strategies in Reading Comprehension by EFL Students

Authors: Simin Sadeghi-Saeb

Abstract:

Metacognitive strategies consistently play important roles in reading comprehension. The metacognitive strategies involve the active monitoring and consequent regulation and orchestration of the cognitive processes in relation to the cognitive objects or data on which they bear. In this paper, the effect of instruction in using metacognitive strategies on reading academic materials, type of metacognitive strategies were mostly used by college university students before and after the instruction and the level they use those strategies before and after the instruction were studied. For these aims, 50 female college students were chosen. Then, they were divided randomly into two groups, experimental and control groups. At first session, students in both groups took the standard TOFEL exam. After the pre-test had been administered, the instruction began. After treatment, a post-test was taken. It is useful to state that after pre-test and post-test the same questionnaire was handed to the students of experimental group. The results of this research show that the instruction of metacognitive strategies has positive effect on the students' scores in reading comprehension tests. Furthermore, it showed that before and after the instruction, the students' usage of metacognitive strategies changed. Also, it demonstrated that the instruction affected the students' level of metacognitive strategies' usage.

Keywords: EFL students, English reading comprehension, instruction, metacognitive strategies

Procedia PDF Downloads 299
9201 Evaluation of High Damping Rubber Considering Initial History through Dynamic Loading Test and Program Analysis

Authors: Kyeong Hoon Park, Taiji Mazuda

Abstract:

High damping rubber (HDR) bearings are dissipating devices mainly used in seismic isolation systems and have a great damping performance. Although many studies have been conducted on the dynamic model of HDR bearings, few models can reflect phenomena such as dependency of experienced shear strain on initial history. In order to develop a model that can represent the dependency of experienced shear strain of HDR by Mullins effect, dynamic loading test was conducted using HDR specimen. The reaction of HDR was measured by applying a horizontal vibration using a hybrid actuator under a constant vertical load. Dynamic program analysis was also performed after dynamic loading test. The dynamic model applied in program analysis is a bilinear type double-target model. This model is modified from typical bilinear model. This model can express the nonlinear characteristics related to the initial history of HDR bearings. Based on the dynamic loading test and program analysis results, equivalent stiffness and equivalent damping ratio were calculated to evaluate the mechanical properties of HDR and the feasibility of the bilinear type double-target model was examined.

Keywords: base-isolation, bilinear model, high damping rubber, loading test

Procedia PDF Downloads 123
9200 Characteristics of Tremella fuciformis and Annulohypoxylon stygium for Optimal Cultivation Conditions

Authors: Eun-Ji Lee, Hye-Sung Park, Chan-Jung Lee, Won-Sik Kong

Abstract:

We analyzed the DNA sequence of the ITS (Internal Transcribed Spacer) region of the 18S ribosomal gene and compared it with the gene sequence of T. fuciformis and Hypoxylon sp. in the BLAST database. The sequences of collected T. fuciformis and Hypoxylon sp. have over 99% homology in the T. fuciformis and Hypoxylon sp. sequence BLAST database. In order to select the optimal medium for T. fuciformis, five kinds of a medium such as Potato Dextrose Agar (PDA), Mushroom Complete Medium (MCM), Malt Extract Agar (MEA), Yeast extract (YM), and Compost Extract Dextrose Agar (CDA) were used. T. fuciformis showed the best growth on PDA medium, and Hypoxylon sp. showed the best growth on MCM. So as to investigate the optimum pH and temperature, the pH range was set to pH4 to pH8 and the temperature range was set to 15℃ to 35℃ (5℃ degree intervals). Optimum culture conditions for the T. fuciformis growth were pH5 at 25℃. Hypoxylon sp. were pH6 at 25°C. In order to confirm the most suitable carbon source, we used fructose, galactose, saccharose, soluble starch, inositol, glycerol, xylose, dextrose, lactose, dextrin, Na-CMC, adonitol. Mannitol, mannose, maltose, raffinose, cellobiose, ethanol, salicine, glucose, arabinose. In the optimum carbon source, T. fuciformis is xylose and Hypoxylon sp. is arabinose. Using the column test, we confirmed sawdust a suitable for T. fuciformis, since the composition of sawdust affects the growth of fruiting bodies of T. fuciformis. The sawdust we used is oak tree, pine tree, poplar, birch, cottonseed meal, cottonseed hull. In artificial cultivation of T. fuciformis with sawdust medium, T. fuciformis and Hypoxylon sp. showed fast mycelial growth on mixture of oak tree sawdust, cottonseed hull, and wheat bran.

Keywords: cultivation, optimal condition, tremella fuciformis, nutritional source

Procedia PDF Downloads 210
9199 The Tribological Behaviors of Vacuum Gas Nitriding Titanium and Steel Substrates at Different Process Temperatures

Authors: Hikmet Cicek

Abstract:

Metal nitrides show excellence tribological properties and they used for especially on machine parts. In this work, the vacuum gas nitriding proses were applied to the titanium, D2 and 52100 steel substrates at three different proses temperatures (500 °C, 600°C and 700 °C). Structural, mechanical and tribological properties of the samples were characterized. X-Ray diffractometer, scanning electron microscope and energy dispersive spectroscopy analyses were conducted to determine structural properties. Microhardness test and pin-on-disc wear test were made to observe tribological properties. Coefficient of friction, wear rate and wear traces were examined comparatively. According to the test results, the process temperature very effective parameter for the vacuum gas nitriding method.

Keywords: gas nitriding, tribology, wear, coating

Procedia PDF Downloads 199
9198 Vibration of Gamma Graphyne with an Attached Mass

Authors: Win-Jin Chang, Haw-Long Lee, Yu-Ching Yang

Abstract:

Atomic finite element simulation is applied to investigate the vibration frequency of a single-layer gamma graphyne with an attached mass for the CCCC, SSSS, CFCF, SFSF boundary conditions using the commercial code ANSYS. The fundamental frequencies of the graphyne sheet are compared with the results of the previous study. The results of the comparison are very good in all considered cases. The attached mass causes a shift in the resonant frequency of the graphyne. The frequencies of the single-layer gamma graphyne with an attached mass for different boundary conditions are obtained, and the order based on the boundary condition is CCCC >SSSS > CFCF> SFSF. The highest frequency shift is obtained when the attached mass is located at the center of the graphyne sheet. This is useful for the design of a highly sensitive graphyne-based mass sensor.

Keywords: graphyne, finite element analysis, vibration analysis, frequency shift

Procedia PDF Downloads 212
9197 Automation Test Method and HILS Environment Configuration for Hydrogen Storage System Management Unit Verification

Authors: Jaejeogn Kim, Jeongmin Hong, Jungin Lee

Abstract:

The Hydrogen Storage System Management Unit (HMU) is a controller that manages hydrogen charging and storage. It detects hydrogen leaks and tank pressure and temperature, calculates the charging concentration and remaining amount, and controls the opening and closing of the hydrogen tank valve. Since this role is an important part of the vehicle behavior and stability of Fuel Cell Electric Vehicles (FCEV), verifying the HMU controller is an essential part. To perform verification under various conditions, it is necessary to increase time efficiency based on an automated verification environment and increase the reliability of the controller by applying numerous test cases. To this end, we introduce the HMU controller automation verification method by applying the HILS environment and an automation test program with the ASAM XIL standard.

Keywords: HILS, ASAM, fuel cell electric vehicle, automation test, hydrogen storage system

Procedia PDF Downloads 70
9196 Developing English L2 Critical Reading and Thinking Skills through the PISA Reading Literacy Assessment Framework: A Case Study of EFL Learners in a Thai University

Authors: Surasak Khamkhong

Abstract:

This study aimed to investigate the use of the PISA reading literacy assessment framework (PRF) to improve EFL learners’ critical reading and thinking skills. The sample group, selected by the purposive sampling technique, included 36 EFL learners from a university in Northeastern Thailand. The instruments consisted of 8 PRF-based reading lessons, a 27-item-PRF-based reading test which was used as a pre-test and a post-test, and an attitude questionnaire toward the designed lessons. The statistics used for data analysis were percentage, mean, standard deviation, and the Wilcoxon signed-rank test. The results revealed that before the intervention, the students’ English reading proficiency were low as is evident from their low pre-test scores (M=14.00). They did fairly well for the access-and-retrieve questions (M=6.11), but poorly for the integrate-and-interpret questions (M=4.89) and the reflect-and-evaluate questions (M=3.00), respectively. This means that the students could comprehend the texts but they could hardly interpret or evaluate them. However, after the intervention, they could do better as their post-test scores were higher (M=18.01). They could comprehend (M=6.78), interpret (M=6.00) and evaluate (M=5.25) well. This means that after the intervention, their critical reading skills had improved. In terms of their attitude towards the designed lessons and instruction, most students were satisfied with the lessons and the instruction. It may thus be concluded that the designed lessons can help improve students’ English critical reading proficiency and may be used as a teaching model for improving EFL learners’ critical reading skills.

Keywords: second language reading, critical reading and thinking skills, PISA reading literacy framework, English L2 reading development

Procedia PDF Downloads 192
9195 A Study on Shear Field Test Method in Timber Shear Modulus Determination Using Stereo Vision System

Authors: Niaz Gharavi, Hexin Zhang

Abstract:

In the structural timber design, the shear modulus of the timber beam is an important factor that needs to be determined accurately. According to BS EN 408, shear modulus can be determined using torsion test or shear field test method. Although torsion test creates pure shear status in the beam, it does not represent the real-life situation when the beam is in the service. On the other hand, shear field test method creates similar loading situation as in reality. The latter method is based on shear distortion measurement of the beam at the zone with the constant transverse load in the standardized four-point bending test as indicated in BS EN 408. Current testing practice code advised using two metallic arms act as an instrument to measure the diagonal displacement of the constructing square. Timber is not a homogenous material, but a heterogeneous and this characteristic makes timber to undergo a non-uniform deformation. Therefore, the dimensions and the location of the constructing square in the area with the constant transverse force might alter the shear modulus determination. This study aimed to investigate the impact of the shape, size, and location of the square in the shear field test method. A binocular stereo vision system was developed to capture the 3D displacement of a grid of target points. This approach is an accurate and non-contact method to extract the 3D coordination of targeted object using two cameras. Two group of three glue laminated beams were produced and tested by the mean of four-point bending test according to BS EN 408. Group one constructed using two materials, laminated bamboo lumber and structurally graded C24 timber and group two consisted only structurally graded C24 timber. Analysis of Variance (ANOVA) was performed on the acquired data to evaluate the significance of size and location of the square in the determination of shear modulus of the beam. The results have shown that the size of the square is an affecting factor in shear modulus determination. However, the location of the square in the area with the constant shear force does not affect the shear modulus.

Keywords: shear field test method, BS EN 408, timber shear modulus, photogrammetry approach

Procedia PDF Downloads 212
9194 Chemical Durability of Textured Glass-coat Suitable for Building Application

Authors: Adejo Andrew Ojonugwa, Jomboh Jeff Kator, Garkida Adele Dzikwi

Abstract:

This study investigates the behaviour of textured glass coat to chemical reactions upon application. Samples of textured glass coat developed from mixed post consumer glass were subjected to pH test (ASTM D5464), Chemical resistance test (ASTM D3260 and D1308), Adhesion test (ASTM D3359), and Abrasion test (ASTM D4060). Results shows a pH of 8.50, Chemical resistance of 5% flick rate when reacted with Sodium hydroxide (NaOH), a 3%, 5%, 10%, and 15% discolouration when reacted with Magnesium hydroxide (Mg(OH)2), Hydrogen fluoride (HF), Potassium hydroxide (KOH) and NaOH respectively, an adhesion of 4A and abrasion of 0.2g. The results confirm that the developed textured glass coat is in line with the standard pH range of 8-9, resistant to acid and base except for HF, NaOH, and Mg(OH)₂, good adhesion and abrasion properties, thereby making the coat resistant to chemical degradation and a good engineering material.

Keywords: chemical durability, glass-coat, building, recycling

Procedia PDF Downloads 113
9193 A Flexible Piezoelectric - Polymer Composite for Non-Invasive Detection of Multiple Vital Signs of Human

Authors: Sarah Pasala, Elizabeth Zacharias

Abstract:

Vital sign monitoring is crucial for both everyday health and medical diagnosis. A significant factor in assessing a human's health is their vital signs, which include heart rate, breathing rate, blood pressure, and electrocardiogram (ECG) readings. Vital sign monitoring has been the focus of many system and method innovations recently. Piezoelectrics are materials that convert mechanical energy into electrical energy and can be used for vital sign monitoring. Piezoelectric energy harvesters that are stretchable and flexible can detect very low frequencies like airflow, heartbeat, etc. Current advancements in piezoelectric materials and flexible sensors have made it possible to create wearable and implantable medical devices that can continuously monitor physiological signals in humans. But because of their non-biocompatible nature, they also produce a large amount of e-waste and require another surgery to remove the implant. This paper presents a biocompatible and flexible piezoelectric composite material for wearable and implantable devices that offers a high-performance platform for seamless and continuous monitoring of human physiological signals and tactile stimuli. It also addresses the issue of e-waste and secondary surgery. A Lead-free piezoelectric, SrBi4Ti4O15, is found to be suitable for this application because the properties can be tailored by suitable substitutions and also by varying the synthesis temperature protocols. In the present work, SrBi4Ti4O15 modified by rare-earth has been synthesized and studied. Coupling factors are calculated from resonant (fr) and anti-resonant frequencies (fa). It is observed that Samarium substitution in SBT has increased the Curie temperature, dielectric and piezoelectric properties. From impedance spectroscopy studies, relaxation, and non-Debye type behaviour are observed. The composite of bioresorbable poly(l-lactide) and Lead-free rare earth modified Bismuth Layered Ferroelectrics leads to a flexible piezoelectric device for non-invasive measurement of vital signs, such as heart rate, breathing rate, blood pressure, and electrocardiogram (ECG) readings and also artery pulse signals in near-surface arteries. These composites are suitable to detect slight movement of the muscles and joints. This Lead-free rare earth modified Bismuth Layered Ferroelectrics – polymer composite is synthesized using a ball mill and the solid-state double sintering method. XRD studies indicated the two phases in the composite. SEM studies revealed the grain size to be uniform and in the range of 100 nm. The electromechanical coupling factor is improved. The elastic constants are calculated and the mechanical flexibility is found to be improved as compared to the single-phase rare earth modified Bismuth Latered piezoelectric. The results indicate that this composite is suitable for the non-invasive detection of multiple vital signs of humans.

Keywords: composites, flexible, non-invasive, piezoelectric

Procedia PDF Downloads 37
9192 Android-Based Edugame Application for Earthquakes Disaster Mitigation Education

Authors: Endina P. Purwandari, Yolanda Hervianti, Feri Noperman, Endang W. Winarni

Abstract:

The earthquakes disaster is an event that can threaten at any moment and cause damage and loss of life. Game earthquake disaster mitigation is a useful educational game to enhance children insight, knowledge, and understanding in the response to the impact of the earthquake. This study aims to build an educational games application on the Android platform as a learning media for earthquake mitigation education and to determine the effect of the application toward children understanding of the earthquake disaster mitigation. The methods were research and development. The development was to develop edugame application for earthquakes mitigation education. The research involved elementary students as a research sample to test the developed application. The research results were valid android-based edugame application, and its the effect of application toward children understanding. The application contains an earthquake simulation video, an earthquake mitigation video, and a game consisting three stages, namely before the earthquake, when the earthquake occur, and after the earthquake. The results of the feasibility test application showed that this application was included in the category of 'Excellent' which the average percentage of the operation of applications by 76%, view application by 67% and contents of application by 74%. The test results of students' responses were 80% that showed that a positive their responses toward the application. The student understanding test results show that the average score of children understanding pretest was 71,33, and post-test was 97,00. T-test result showed that t value by 8,02 more than table t by 2,001. This indicated that the earthquakes disaster mitigation edugame application based on Android platform affects the children understanding about disaster earthquake mitigation.

Keywords: android, edugame, mitigation, earthquakes

Procedia PDF Downloads 364
9191 Validating the Arabic Communicative Development Inventory for Assessing the Development of Language in Arabic-Speaking Children

Authors: Alshaimaa Abdelwahab, Allegra Cattani, Caroline Floccia

Abstract:

Assessing children’s language is fundamental for changing their developmental outcome as it gives a chance for a quick and early intervention with the suitable planning and monitoring program. The importance of language assessment lies in helping to find the right test fit for purpose, in addition to achievement and proficiency. This study examines the validity of a new Arabic assessment tool, the Arabic Communicative Development Inventory ‘Arabic CDI’. It assesses the development of language in Arabic children in different Arabic countries, allowing to detect children with language delay. A concurrent validity is set to compare the Arabic CDI to the Arabic Language test. Twenty-three typically developing Egyptian healthy children and their mothers participated in this study. Their age is 24 months (+ or -) two weeks. The sample included 13 males and 10 females. Mothers completed the Arabic CDI either before or after the Arabic Language Test was conducted with the child. The score for comprehension in the Arabic CDI (M= 52.7, SD= 9.7) and words understood in the Arabic Language Test (M= 59.6, SD= 12.5) were strongly and positively correlated (r= .62, p= .002). At the same time, the scores for production in the Arabic CDI (M= 38.4, SD= 14.8) and words expressed in the Arabic Language Test (M= 52.1, SD= 16.3) were also strongly and positively correlated (r= .82, p= .000). The new Arabic CDI is an adequate tool for assessing the development of comprehension and production at Arabic children. In addition, it could be used for detecting children with language impairment. Standardization of the Arabic CDI across 18 different Arabic dialects in children aged 8 to 30 months is underway.

Keywords: Arabic CDI, assessing children, language development, language impairment

Procedia PDF Downloads 472
9190 A Field Study of Monochromatic Light Effects on Antibody Responses to Newcastle Disease by HI Test and the Correlation with ELISA

Authors: Seyed Mehrzad Pahlavani, Mozaffar Haji Jafari Anaraki, Sayma Mohammadi

Abstract:

A total of 34700 day-old broilers were exposed to green, blue and yellow light using a light-emitting diode system for 6 weeks to investigate the effects of light wave length on antibody responses to Newcastle disease by HI test and the correlation with ELISA. 3 poultry house broiler farms with the same conditions was selected and the lightening system of each was set according to the requirement. Blood samples were taken from 20 chicks on days 1, 24 and 46 and the Newcastle virus specific antibody was titered in serum using HI an ELISA test. On day 24, the probability value of more than 0/05 was observed in HI and ELISA tests of all groups while at the end of breeding period, the average HI serum antibody titer was more in the green light than the yellow one while the blue light was not significantly different from both. At the last titration, the green light has got the highest titer of Newcastle antibodies. There were no significant differences of Newcastle antibody titers between all groups and ages in broiler pullets in ELISA. According to the sampling and analysis of HI and ELISA serum tests, there were no significant relationships between all broiler pullets breeding in green, blue and yellow light on days 24 and 46 and the P-value was more than 0/05. It is suggested that the monochromatic light is effective on broilers immunity against Newcastle disease.

Keywords: monochromatic light, Newcastle disease, HI test, ELISA test

Procedia PDF Downloads 657
9189 The Effect of Core Training on Physical Fitness Characteristics in Male Volleyball Players

Authors: Sibel Karacaoglu, Fatma Ç. Kayapinar

Abstract:

The aim of the study is to investigate the effect of the core training program on physical fitness characteristics and body composition in male volleyball players. 26 male university volleyball team players aged between 19 to 24 years who had no health problems and injury participated in the study. Subjects were divided into training (TG) and control groups (CG) as randomly. Data from twenty-one players who completed all training sessions were used for statistical analysis (TG,n=11; CG,n=10). A core training program was applied to the training group three days a week for 10 weeks. On the other hand, the control group did not receive any training. Before and after the 10-week training program, pre- and post-testing comprised of body composition measurements (weight, BMI, bioelectrical impedance analysis) and physical fitness measurements including flexibility (sit and reach test), muscle strength (back, leg and grip strength by dynamometer), muscle endurance (sit-ups and push-ups tests), power (one-legged jump and vertical jump tests), speed (20m sprint, 30m sprint) and balance tests (one-legged standing test) were performed. Changes of pre- and post- test values of the groups were determined by using dependent t test. According to the statistical analysis of data, no significant difference was found in terms of body composition in the both groups for pre- and post- test values. In the training group, all physical fitness measurements improved significantly after core training program (p<0.05) except 30m speed and handgrip strength (p>0.05). On the hand, only 20m speed test values improved after post-test period (p<0.05), but the other physical fitness tests values did not differ (p>0.05) between pre- and post- test measurement in the control group. The results of the study suggest that the core training program has positive effect on physical fitness characteristics in male volleyball players.

Keywords: body composition, core training, physical fitness, volleyball

Procedia PDF Downloads 346
9188 Non-Invasive Viscosity Determination of Liquid Organic Hydrogen Carriers by Alteration of Temperature and Flow Velocity Using Cavity Based Permittivity Measurement

Authors: I. Wiemann, N. Weiß, E. Schlücker, M. Wensing, A. Kölpin

Abstract:

Chemical storage of hydrogen by liquid organic hydrogen carriers (LOHC) is a very promising alternative to compression or cryogenics. These carriers have high energy density and allow at the same time efficient and safe storage of hydrogen under ambient conditions and without leakage losses. Another benefit of LOHC is the possibility to transport it using already available infrastructure for transport of fossil fuels. Efficient use of LOHC is related to a precise process control, which requires a number of sensors in order to measure all relevant process parameters, for example, to measure the level of hydrogen loading of the carrier. The degree of loading is relevant for the energy content of the storage carrier and represents simultaneously the modification in chemical structure of the carrier molecules. This variation can be detected in different physical properties like viscosity, permittivity or density. Thereby, each degree of loading corresponds to different viscosity values. Conventional measurements currently use invasive viscosity measurements or near-line measurements to obtain quantitative information. Avoiding invasive measurements has several severe advantages. Efforts are currently taken to provide a precise, non-invasive measurement method with equal or higher precision of the obtained results. This study investigates a method for determination of the viscosity of LOHC. Since the viscosity can retroactively derived from the degree of loading, permittivity is a target parameter as it is a suitable for determining the hydrogenation degree. This research analyses the influence of common physical properties on permittivity. The permittivity measurement system is based on a cavity resonator, an electromagnetic resonant structure, whose resonation frequency depends on its dimensions as well as the permittivity of the medium inside. For known resonator dimensions, the resonation frequency directly characterizes the permittivity. In order to determine the dependency of the permittivity on temperature and flow velocity, an experimental setup with heating device and flow test bench was designed. By varying temperature in the range of 293,15 K -393,15 K and flow velocity up to 140 mm/s, corresponding changes in the resonation frequency were measured in the hundredths of the GHz range.

Keywords: liquid organic hydrogen carriers, measurement, permittivity, viscosity., temperature, flow process

Procedia PDF Downloads 100
9187 Student Performance and Confidence Analysis on Education Virtual Environments through Different Assessment Strategies

Authors: Rubén Manrique, Delio Balcázar, José Parrado, Sebastián Rodríguez

Abstract:

Hand in hand with the evolution of technology, education systems have moved to virtual environments to provide increased coverage and facilitate the access to education. However, measuring student performance in virtual environments presents significant challenges to ensure students are acquiring the expected skills. In this study, the confidence and performance of engineering students in virtual environments is analyzed through different evaluation strategies. The effect of the assessment strategy in student confidence is identified using educational data mining techniques. Four assessment strategies were used. First, a conventional multiple choice test; second, a multiple choice test with feedback; third, a multiple choice test with a second chance; and fourth; a multiple choice test with feedback and second chance. Our results show that applying testing with online feedback strategies can influence positively student confidence.

Keywords: assessment strategies, educational data mining, student performance, student confidence

Procedia PDF Downloads 354
9186 Power Transformer Risk-Based Maintenance by Optimization of Transformer Condition and Transformer Importance

Authors: Kitti Leangkrua

Abstract:

This paper presents a risk-based maintenance strategy of a power transformer in order to optimize operating and maintenance costs. The methodology involves the study and preparation of a database for the collection the technical data and test data of a power transformer. An evaluation of the overall condition of each transformer is performed by a program developed as a result of the measured results; in addition, the calculation of the main equipment separation to the overall condition of the transformer (% HI) and the criteria for evaluating the importance (% ImI) of each location where the transformer is installed. The condition assessment is performed by analysis test data such as electrical test, insulating oil test and visual inspection. The condition of the power transformer will be classified from very poor to very good condition. The importance is evaluated from load criticality, importance of load and failure consequence. The risk matrix is developed for evaluating the risk of each power transformer. The high risk power transformer will be focused firstly. The computerized program is developed for practical use, and the maintenance strategy of a power transformer can be effectively managed.

Keywords: asset management, risk-based maintenance, power transformer, health index

Procedia PDF Downloads 306
9185 Diagnostic Accuracy of the Tuberculin Skin Test for Tuberculosis Diagnosis: Interest of Using ROC Curve and Fagan’s Nomogram

Authors: Nouira Mariem, Ben Rayana Hazem, Ennigrou Samir

Abstract:

Background and aim: During the past decade, the frequency of extrapulmonary forms of tuberculosis has increased. These forms are under-diagnosed using conventional tests. The aim of this study was to evaluate the performance of the Tuberculin Skin Test (TST) for the diagnosis of tuberculosis, using the ROC curve and Fagan’s Nomogram methodology. Methods: This was a case-control, multicenter study in 11 anti-tuberculosis centers in Tunisia, during the period from June to November2014. The cases were adults aged between 18 and 55 years with confirmed tuberculosis. Controls were free from tuberculosis. A data collection sheet was filled out and a TST was performed for each participant. Diagnostic accuracy measures of TST were estimated using ROC curve and Area Under Curve to estimate sensitivity and specificity of a determined cut-off point. Fagan’s nomogram was used to estimate its predictive values. Results: Overall, 1053 patients were enrolled, composed of 339 cases (sex-ratio (M/F)=0.87) and 714 controls (sex-ratio (M/F)=0.99). The mean age was 38.3±11.8 years for cases and 33.6±11 years for controls. The mean diameter of the TST induration was significantly higher among cases than controls (13.7mm vs.6.2mm;p=10-6). Area Under Curve was 0.789 [95% CI: 0.758-0.819; p=0.01], corresponding to a moderate discriminating power for this test. The most discriminative cut-off value of the TST, which were associated with the best sensitivity (73.7%) and specificity (76.6%) couple was about 11 mm with a Youden index of 0.503. Positive and Negative predictive values were 3.11% and 99.52%, respectively. Conclusion: In view of these results, we can conclude that the TST can be used for tuberculosis diagnosis with a good sensitivity and specificity. However, the skin induration measurement and its interpretation is operator dependent and remains difficult and subjective. The combination of the TST with another test such as the Quantiferon test would be a good alternative.

Keywords: tuberculosis, tuberculin skin test, ROC curve, cut-off

Procedia PDF Downloads 67
9184 Prevalence, Isolation and Identification of Feline Panleukopaenia Virus from Wild Felids in Nandankanan Zoo, Odisha

Authors: Arun Kharate, Sarata Kumar Sahu, Susen Kumar Panda, Niranjan Sahoo, H. K. Panda

Abstract:

In the present study, an attempt has been made for isolation and identification of feline panleukopaenia virus (FPLV) from wild felids of Nandankanan zoo, Odisha, India, along with prevalence study of FPLV. Fecal samples collected from wild felids (26 tigers, 22 lions, 5 leopards, 3 hyenas, 1 jaguar, 2 foxes and 1 wild cat) were subjected to hemagglutinnation test and fluorescent antibody test. In hemagglutinnation test 13 (50%) samples from tiger, 14 (63.63%) samples from lions, 1 (20%) sample from leopards, 1 (50%) from fox, 3 (100%) samples from hyenas and 1 (100%) sample from wild cat were positive. On fluorescent antibody test (FAT), 15 (57.69%) samples from tiger, 18 (81.81%) from lions, 2 (40%) from leopards, 1 (50%) from fox, 3 (100%) from hyenas and 1 (100%) from wild cat were positive. FPLV was isolated using MDBK cell line and preliminary characterization was done on the basis of characteristic cytopathic effect. The virus samples were quantified through titration in MDBK cells. Serological confirmation of FPLV isolates was carried out by HI test, micro-SNT and indirect-ELISA. Physico-chemical characters like pH and temperature resistance along molecular identification using specific FPLV primers was carried out. Seroprevalence study of 36 serum samples employing HI test, micro SNT and indirect-ELISA revealed prevalence of 38.8, 44.4 and 72.2% respectively. During study period an adult tigress and a tiger cub died suspected of feline panleukopenia. The necropsy findings in both animals showed hemorrhagic gastroenteritis. The cytological examination revealed presence of intranuclear inclusion bodies in the intestinal epithelial cells. Spleen, mesenteric lymph node and intestine were positive for feline panleukopenia by FAT. The investigation revealed that feline panleukopenia was prevalent in wild felines of Nandankanan zoo.

Keywords: Feline panleukopenia, fluorescent antibody test, hemagglutination test, indirect-ELISA, Nandankanan zoo

Procedia PDF Downloads 326
9183 In vivo Antiplatelet Activity Test of Wet Extract of Mimusops elengi L.'s Leaves on DDY Strain Mice as an Effort to Treat Atherosclerosis

Authors: Dewi Tristantini, Jason Jonathan

Abstract:

Coronary Artery Disease (CAD) is one of the deathliest diseases which is caused by atherosclerosis. Atherosclerosis is a disease that plaque builds up inside the arteries. Plaque is made up of fat, cholesterol, calcium, platelet, and other substances found in blood. The current treatment of atherosclerosis is to provide antiplatelet therapy treatment, but such treatments often cause gastrointestinal irritation, muscle pain and hormonal imbalance. Mimusops elengi L.’s leaves can be utilized as a natural and cheap antiplatelet’s source because it contains flavonoids such as quertecin. Antiplatelet aggregation effect of Mimusops elengi L.’s leaves’ wet extract was measured by bleeding time on DDY strain mice with the test substances were given orally during the period of 8 days. The bleeding time was measured on first day and 9th day. Empirically, the dose which is used for humans is 8.5 g of leaves in 600 ml of water. This dose is equivalent to 2.1 g of leaves in 350 ml of water for mice. The extract was divided into 3 doses for mice: 0.05 ml/day; 0.1 ml/day; 0.2 ml/day. After getting the percentage of the increase in bleeding time, data were analyzed by analysis of variance test (Anova), followed by individual comparison within the groups by LSD test. The test substances above respectively increased bleeding time 21%, 62%, and 128%. As the conclusion, the 0.02 ml/day dose of Mimusops elengi L.’s leaves’ wet extract could increase bleeding time better than clopidogrel as positive controls with 110% increase in bleeding time.

Keywords: antiplatelets, atheroschlerosis, bleeding time, Mimusops elengi

Procedia PDF Downloads 264
9182 Diagnostics of Subclinical Mastitis in Dairy Cows

Authors: G. Tanbayeva, Z. Myrzabekov, O. Tagayev, B. Barakhov, M. Tokayeva

Abstract:

Mastitis is widely spread among dairy cows bringing large economic damage resulting in decreased milk yield, deterioration of the milk quality, gastrointestinal tract disorders among young animals, culling of breeding stock, and expenses for sick animal treatment. Up-to-date and accurate diagnostics of subclinical (latent) mastitis in dairy cows has huge practical and economical significance. The aim of the research was to develop a new optimal alternative rapid method for the diagnosis of subclinical mastitis in cows. The study was performed in the laboratory of the Hygiene and Sanitation of Kazakh National Agrarian University. The first stage was to evaluate the different percentages of “Promastit” preparation. It showed that the best diagnostics capacity had 10% dilution. The second stage was to compare “Promastit” with some of the domestic and foreign analogues “Somatic-Test” (Denmark), “MastTest” (Russia), “Mastidin” (Ukraine), “Diagmast” (Kazakhstan). The observation was carried out on 520 dairy cows with subclinical mastitis on farms of Almaty region of Kazakhstan. The effectiveness was checked by milk sedimentation test. Our research tends to show that the diagnostic test "Promastitis" revealed subclinical mastitis in 193 out of 520 lactating cows (37.1% of those examined). At the same time, in the case of using other diagnostic tests, the given index was as follows: 35.5% (mastidin), 34.4% (masttest-AF), 33.8% (somatic-test Ecotest), 30.7% (diagmast).

Keywords: dairy cows, diagnostics, subclinical mastitis, test Promastit

Procedia PDF Downloads 354
9181 Comparison of Visual Field Tests in Glaucoma Patients with a Central Visual Field Defect

Authors: Hye-Young Shin, Hae-Young Lopilly Park, Chan Kee Park

Abstract:

We compared the 24-2 and 10-2 visual fields (VFs) and investigate the degree of discrepancy between the two tests in glaucomatous eyes with central VF defects. In all, 99 eyes of 99 glaucoma patients who underwent both the 24-2 VF and 10-2 VF tests within 6 months were enrolled retrospectively. Glaucomatous eyes involving a central VF defect were divided into three groups based on the average total deviation (TD) of 12 central points in the 24-2 VF test (N = 33, in each group): group 1 (tercile with the highest TD), group 2 (intermediate TD), and group 3 (lowest TD). The TD difference was calculated by subtracting the average TD of the 10-2 VF test from the average TD of 12 central points in the 24-2 VF test. The absolute central TD difference in each quadrant was defined as the absolute value of the TD value obtained by subtracting the average TD of four central points in the 10-2 VF test from the innermost TD in the 24-2 VF test in each quadrant. The TD differences differed significantly between group 3 and groups 1 and 2 (P < 0.001). In the superonasal quadrant, the absolute central TD difference was significantly greater in group 2 than in group 1 (P < 0.05). In the superotemporal quadrant, the absolute central TD difference was significantly greater in group 3 than in groups 1 and 2 (P < 0.001). Our results indicate that the results of VF tests for different VFs can be inconsistent, depending on the degree of central defects and the VF quadrant.

Keywords: central visual field defect, glaucoma, 10-2 visual field, 24-2 visual field

Procedia PDF Downloads 176