Search results for: comfort zones
1213 Energy Refurbishment of University Building in Cold Italian Climate: Energy Audit and Performance Optimization
Authors: Fabrizio Ascione, Martina Borrelli, Rosa Francesca De Masi, Silvia Ruggiero, Giuseppe Peter Vanoli
Abstract:
The Directive 2010/31/EC 'Directive of the European Parliament and of the Council of 19 may 2010 on the energy performance of buildings' moved the targets of the previous version toward more ambitious targets, for instance by establishing that, by 31 December 2020, all new buildings should demand nearly zero-energy. Moreover, the demonstrative role of public buildings is strongly affirmed so that also the target nearly zero-energy buildings is anticipated, in January 2019. On the other hand, given the very low turn-over rate of buildings (in Europe, it ranges between 1-3%/yearly), each policy that does not consider the renovation of the existing building stock cannot be effective in the short and medium periods. According to this proposal, the study provides a novel, holistic approach to design the refurbishment of educational buildings in colder cities of Mediterranean regions enabling stakeholders to understand the uncertainty to use numerical modelling and the real environmental and economic impacts of adopting some energy efficiency technologies. The case study is a university building of Molise region in the centre of Italy. The proposed approach is based on the application of the cost-optimal methodology as it is shown in the Delegate Regulation 244/2012 and Guidelines of the European Commission, for evaluating the cost-optimal level of energy performance with a macroeconomic approach. This means that the refurbishment scenario should correspond to the configuration that leads to lowest global cost during the estimated economic life-cycle, taking into account not only the investment cost but also the operational costs, linked to energy consumption and polluting emissions. The definition of the reference building has been supported by various in-situ surveys, investigations, evaluations of the indoor comfort. Data collection can be divided into five categories: 1) geometrical features; 2) building envelope audit; 3) technical system and equipment characterization; 4) building use and thermal zones definition; 5) energy building data. For each category, the required measures have been indicated with some suggestions for the identifications of spatial distribution and timing of the measurements. With reference to the case study, the collected data, together with a comparison with energy bills, allowed a proper calibration of a numerical model suitable for the hourly energy simulation by means of EnergyPlus. Around 30 measures/packages of energy, efficiency measure has been taken into account both on the envelope than regarding plant systems. Starting from results, two-point will be examined exhaustively: (i) the importance to use validated models to simulate the present performance of building under investigation; (ii) the environmental benefits and the economic implications of a deep energy refurbishment of the educational building in cold climates.Keywords: energy simulation, modelling calibration, cost-optimal retrofit, university building
Procedia PDF Downloads 1781212 Quality Characteristics of Road Runoff in Coastal Zones: A Case Study in A25 Highway, Portugal
Authors: Pedro B. Antunes, Paulo J. Ramísio
Abstract:
Road runoff is a linear source of diffuse pollution that can cause significant environmental impacts. During rainfall events, pollutants from both stationary and mobile sources, which have accumulated on the road surface, are dragged through the superficial runoff. Road runoff in coastal zones may present high levels of salinity and chlorides due to the proximity of the sea and transported marine aerosols. Appearing to be correlated to this process, organic matter concentration may also be significant. This study assesses this phenomenon with the purpose of identifying the relationships between monitored water quality parameters and intrinsic site variables. To achieve this objective, an extensive monitoring program was conducted on a Portuguese coastal highway. The study included thirty rainfall events, in different weather, traffic and salt deposition conditions in a three years period. The evaluations of various water quality parameters were carried out in over 200 samples. In addition, the meteorological, hydrological and traffic parameters were continuously measured. The salt deposition rates (SDR) were determined by means of a wet candle device, which is an innovative feature of the monitoring program. The SDR, variable throughout the year, appears to show a high correlation with wind speed and direction, but mostly with wave propagation, so that it is lower in the summer, in spite of the favorable wind direction in the case study. The distance to the sea, topography, ground obstacles and the platform altitude seems to be also relevant. It was confirmed the high salinity in the runoff, increasing the concentration of the water quality parameters analyzed, with significant amounts of seawater features. In order to estimate the correlations and patterns of different water quality parameters and variables related to weather, road section and salt deposition, the study included exploratory data analysis using different techniques (e.g. Pearson correlation coefficients, Cluster Analysis and Principal Component Analysis), confirming some specific features of the investigated road runoff. Significant correlations among pollutants were observed. Organic matter was highlighted as very dependent of salinity. Indeed, data analysis showed that some important water quality parameters could be divided into two major clusters based on their correlations to salinity (including organic matter associated parameters) and total suspended solids (including some heavy metals). Furthermore, the concentrations of the most relevant pollutants seemed to be very dependent on some meteorological variables, particularly the duration of the antecedent dry period prior to each rainfall event and the average wind speed. Based on the results of a monitoring case study, in a coastal zone, it was proven that SDR, associated with the hydrological characteristics of road runoff, can contribute for a better knowledge of the runoff characteristics, and help to estimate the specific nature of the runoff and related water quality parameters.Keywords: coastal zones, monitoring, road runoff pollution, salt deposition
Procedia PDF Downloads 2391211 Cataloguing Beetle Fauna (Insecta: Coleoptera) of India: Estimating Diversity, Distribution, and Taxonomic Challenges
Authors: Devanshu Gupta, Kailash Chandra, Priyanka Das, Joyjit Ghosh
Abstract:
Beetles, in the insect order Coleoptera are the most species-rich group on this planet today. They represent about 40% of the total insect diversity of the world. With a considerable range of landform types including significant mountain ranges, deserts, fertile irrigational plains, and hilly forested areas, India is one of the mega-diverse countries and includes more than 0.1 million faunal species. Despite having rich biodiversity, the efforts to catalogue the beetle diversity of the extant species/taxa reported from India have been less. Therefore, in this paper, the information on the beetle fauna of India is provided based on the data available with the museum collections of Zoological Survey of India and taxa extracted from zoological records and published literature. The species were listed with their valid names, synonyms, type localities, type depositories, and their distribution in states and biogeographic zones of India. The catalogue also incorporates the bibliography on Indian Coleoptera. The exhaustive species inventory, prepared by us include distributional records from Himalaya, Trans Himalaya, Desert, Semi-Arid, Western Ghats, Deccan Peninsula, Gangetic Plains, Northeast, Islands, and Coastal areas of the country. Our study concludes that many of the species are still known from their type localities only, so there is need to revisit and resurvey those collection localities for the taxonomic evaluation of those species. There are species which exhibit single locality records, and taxa-specific biodiversity assessments are required to be undertaken to understand the distributional range of such species. The primary challenge is taxonomic identifications of the species which were described before independence, and the type materials are present in overseas museums. For such species, taxonomic revisions of the different group of beetles are required to solve the problems of identification and classification.Keywords: checklist, taxonomy, museum collections, biogeographic zones
Procedia PDF Downloads 2741210 Textile-Based Sensing System for Sleep Apnea Detection
Authors: Mary S. Ruppert-Stroescu, Minh Pham, Bruce Benjamin
Abstract:
Sleep apnea is a condition where a person stops breathing and can lead to cardiovascular disease, hypertension, and stroke. In the United States, approximately forty percent of overnight sleep apnea detection tests are cancelled. The purpose of this study was to develop a textile-based sensing system that acquires biometric signals relevant to cardiovascular health, to transmit them wirelessly to a computer, and to quantitatively assess the signals for sleep apnea detection. Patient interviews, literature review and market analysis defined a need for a device that ubiquitously integrated into the patient’s lifestyle. A multi-disciplinary research team of biomedical scientists, apparel designers, and computer engineers collaborated to design a textile-based sensing system that gathers EKG, Sp02, and respiration, then wirelessly transmits the signals to a computer in real time. The electronic components were assembled from existing hardware, the Health Kit which came pre-set with EKG and Sp02 sensors. The respiration belt was purchased separately and its electronics were built and integrated into the Health Kit mother board. Analog ECG signals were amplified and transmitted to the Arduino™ board where the signal was converted from analog into digital. By using textile electrodes, ECG lead-II was collected, and it reflected the electrical activity of the heart. Signals were collected when the subject was in sitting position and at sampling rate of 250 Hz. Because sleep apnea most often occurs in people with obese body types, prototypes were developed for a man’s size medium, XL, and XXL. To test user acceptance and comfort, wear tests were performed on 12 subjects. Results of the wear tests indicate that the knit fabric and t-shirt-like design were acceptable from both lifestyle and comfort perspectives. The airflow signal and respiration signal sensors return good signals regardless of movement intensity. Future study includes reconfiguring the hardware to a smaller size, developing the same type of garment for the female body, and further enhancing the signal quality.Keywords: sleep apnea, sensors, electronic textiles, wearables
Procedia PDF Downloads 2741209 High Impact Biosratigraphic Study Of Amama-1 and Bara-1 Wells In Parts of Anambra Basin
Authors: J. O. Njoku, G. C. Soronnadi-ononiwu, E. J. Acrra, C. C. Agoha, T. C. Anyawu
Abstract:
The High Impact Biostratigrapgic Study of parts of Anambra basin was carried out using samples from two exploration wells (Amama-1 and Bara-1), Amama-1 (219M–1829M) and Bara-1 (317M-1594M). Palynological and Paleontological analyses were carried out on 100 ditch cutting samples. The faunal and floral succession were of terrestrial and marine origin as described and logged. The well penetrated four stratigraphic units in Anambra Basin (the Nkporo, Mamu, Ajali and Nsukka) the wells yielded well preserved formanifera and palynormorphs. The well yielded 53 species of foram and 69 species of palynomorphs, with 12 genera Bara-1 (25 Species of foram and 101 species of palynormorphs). Amama-1permitted the recognition of 21 genera with 31 formainiferal assemblage zones, 32 pollen and 37 spores assemblage zones, and dinoflagellate cyst, biozonation, ranging from late Campanian – early Paleocene. Bara-1 yielded (60 pollen, 41 spore assemblage zone and 18 dinoflagellate cyst).The zones, in stratigraphically ascending order for the foraminifera and palynomorphs are as follows. Amama Biozone A-Globotruncanella havanensis zone: Late Campanian –Maastrichtian (695 – 1829m) Biozone B-Morozovella velascoensis zone: Early Paleocene(165–695m) Bara-1 Biozone A-Globotruncanella havanensis zone: Late Campanian(1512m) Biozone B-Bolivina afra, B. explicate zone: Maastrichtian (634–1204m) Biozone C - Indeterminate (305 – 634m) palynomorphs Amama-1 A.Ctenolophonidites costatus zone:Early Maastrichtian (1829m) B-Retidiporites miniporatus Zone: Late Maastrichtian (1274m) Constructipollenites ineffectus Zone: Early Paleocene(695m) Bara-1 Droseridites senonicus Zone: Late Campanian (994– 1600m) B. Ctenolophonidites costatus Zone: Early Maastrichtian (713–994m) C. Retidiporites miniporatus Zone: Late Maastrichtian (305 –713m) The paleo – environment of deposition were determined to range from non-marine to outer netritic. A detailed categorization of the palynormorphs into terrestrially derived palynormorphs and marine derived palynormorphs based on the distribution of three broad vegetational types; mangrove, fresh water swamps and hintherland communities were used to evaluate sea level fluctuations with respect to sediments deposited in the basins and linked with a particular depositional system tract. Amama-1 recorded 4 maximum flooding surface(MFS) at depth 165-1829, dated b/w 61ma-76ma and three sequence boundary(SB) at depth1048m - 1533m and 1581 dated b/w 634m - 1387m, dated 69.5ma - 82ma and four sequence boundary(SB) at 552m-876m, dated 68ma-77.5ma respectively. The application of ecostratigraphic description is characterised by the prominent expansion of the hinterland component consisting of the Mangrove to Lowland Rainforest and Afromontane – Savannah vegetation.Keywords: formanifera, palynomorphs. campanian, maastritchian, ecostratigraphic, anambra
Procedia PDF Downloads 131208 Experience in Caring for a Patient with Terminal Aortic Dissection of Lung Cancer and Paralysis of the Lower Limbs after Surgery
Authors: Pei-Shan Liang
Abstract:
Objective: This article explores the care experience of a terminal lung cancer patient who developed lower limb paralysis after surgery for aortic dissection. The patient, diagnosed with aortic dissection during chemotherapy for lung cancer, faced post-surgical lower limb paralysis, leading to feelings of helplessness and hopelessness as they approached death with reduced mobility. Methods: The nursing period was from July 19 to July 27, during which the author, alongside the intensive care team and palliative care specialists, conducted a comprehensive assessment through observation, direct care, conversations, physical assessments, and medical record review. Gordon's eleven functional health patterns were used for a holistic evaluation, identifying four nursing health issues: "pain related to terminal lung cancer and invasive procedures," "decreased cardiac tissue perfusion due to hemodynamic instability," "impaired physical mobility related to lower limb paralysis," and "hopelessness due to the unpredictable prognosis of terminal lung cancer." Results: The medical team initially focused on symptom relief, administering Morphine 5mg in 0.9% N/S 50ml IVD q6h for pain management and continuing chemotherapy as prescribed. Open communication was employed to address the patient's physical, psychological, and spiritual concerns. Non-pharmacological interventions, including listening, caring, companionship, opioid medication, and distraction techniques like comfortable positioning and warm foot baths, were used to alleviate pain, reducing the pain score to 3 on the numeric rating scale and easing respiratory discomfort. The palliative care team was also involved, guiding the patient and family through the "Four Paths of Life," helping the patient achieve a good end-of-life experience and the family to experience a peaceful life. This process also served to promote the concept of palliative care, enabling more patients and families to receive high-quality and dignified care. The patient was encouraged to express inner anxiety through drawing or writing, which helped reduce the hopelessness caused by psychological distress and uncertainty about the disease's prognosis, as assessed by the Hospital Anxiety and Depression Scale, reaching a level of mild anxiety but acceptable without affecting sleep. Conclusion: What left a deep impression during the care process was the need for intensive care providers to consider the patient's psychological state, not just their physical condition, when the patient's situation changes. Family support and involvement often provide the greatest solace for the patient, emphasizing the importance of comfort and dignity. This includes oral care to maintain cleanliness and comfort, frequent repositioning to alleviate pressure and discomfort, and timely removal of invasive devices and unnecessary medications to avoid unnecessary suffering. The nursing process should also address the patient's psychological needs, offering comfort and support to ensure that they can face the end of life with peace and dignity.Keywords: intensive care, lung cancer, aortic dissection, lower limb paralysis
Procedia PDF Downloads 251207 Specification Requirements for a Combined Dehumidifier/Cooling Panel: A Global Scale Analysis
Authors: Damien Gondre, Hatem Ben Maad, Abdelkrim Trabelsi, Frédéric Kuznik, Joseph Virgone
Abstract:
The use of a radiant cooling solution would enable to lower cooling needs which is of great interest when the demand is initially high (hot climate). But, radiant systems are not naturally compatibles with humid climates since a low-temperature surface leads to condensation risks as soon as the surface temperature is close to or lower than the dew point temperature. A radiant cooling system combined to a dehumidification system would enable to remove humidity for the space, thereby lowering the dew point temperature. The humidity removal needs to be especially effective near the cooled surface. This requirement could be fulfilled by a system using a single desiccant fluid for the removal of both excessive heat and moisture. This task aims at providing an estimation of the specification requirements of such system in terms of cooling power and dehumidification rate required to fulfill comfort issues and to prevent any condensation risk on the cool panel surface. The present paper develops a preliminary study on the specification requirements, performances and behavior of a combined dehumidifier/cooling ceiling panel for different operating conditions. This study has been carried using the TRNSYS software which allows nodal calculations of thermal systems. It consists of the dynamic modeling of heat and vapor balances of a 5m x 3m x 2.7m office space. In a first design estimation, this room is equipped with an ideal heating, cooling, humidification and dehumidification system so that the room temperature is always maintained in between 21◦C and 25◦C with a relative humidity in between 40% and 60%. The room is also equipped with a ventilation system that includes a heat recovery heat exchanger and another heat exchanger connected to a heat sink. Main results show that the system should be designed to meet a cooling power of 42W.m−2 and a desiccant rate of 45 gH2O.h−1. In a second time, a parametric study of comfort issues and system performances has been achieved on a more realistic system (that includes a chilled ceiling) under different operating conditions. It enables an estimation of an acceptable range of operating conditions. This preliminary study is intended to provide useful information for the system design.Keywords: dehumidification, nodal calculation, radiant cooling panel, system sizing
Procedia PDF Downloads 1751206 High Impact Ecostratigraphic and Biostratigrapgic Study of Amama-1 and Bara-1 Wells in Parts of Anambra Basin
Authors: J. O. Njoku, G. C. Soronnadi-Ononiwu, E. J. Acrra, C. C. Agoha, T. C. Anyawu
Abstract:
The high impact ecostratigraphic and biostratigrapgic study of parts of Anambra basin was carried out using samples from two exploration wells (Amama-1 and Bara-1), Amama-1 (219M–1829M) and Bara-1 (317M-1594M). Palynological and paleontological analyses were carried out on 100 ditch-cutting samples. The faunal and floral succession were of terrestrial and marine origin as described and logged. The well penetrated four stratigraphic units in Anambra Basin (the Nkporo, Mamu, Ajali and Nsukka) the wells yielded well preserved formanifera and palynormorphs. The well yielded 53 species of foram and 69 species of palynomorphs, with 12 genera Bara-1 (25 Species of foram and 101 species of palynormorphs). Amama-1 permitted the recognition of 21 genera with 31 formainiferal assemblage zones, 32 pollen and 37 spores assemblage zones, and dinoflagellate cyst, biozonation, ranging from late Campanian – early Paleocene. Bara-1 yielded (60 pollen, 41 spore assemblage zone and 18 dinoflagellate cyst). The zones, in stratigraphically ascending order for the foraminifera and palynomorphs are as follows: Amama Biozone A-Globotruncanella havanensis zone: Late Campanian –Maastrichtian (695 – 1829m) Biozone B-Morozovella velascoensis zone: Early Paleocene(165–695m) Bara-1 Biozone A-Globotruncanella havanensis zone: Late Campanian(1512m) Biozone B-Bolivina afra, B. explicate zone: Maastrichtian (634–1204m) Biozone C - Indeterminate (305 – 634m) palynomorphs Amama-1 A. Ctenolophonidites costatus zone: Early Maastrichtian (1829m) B-Retidiporites miniporatus Zone: Late Maastrichtian (1274m) Constructipollenites ineffectus Zone: Early Paleocene(695m) Bara-1 Droseridites senonicus Zone: Late Campanian (994– 1600m) B. Ctenolophonidites costatus Zone: Early Maastrichtian (713–994m) C. Retidiporites miniporatus Zone: Late Maastrichtian (305 –713m) The paleo-environment of deposition were determined to range from non-marine to outer netritic. A detailed categorization of the palynormorphs into terrestrially derived palynormorphs and marine derived palynormorphs based on the distribution of three broad vegetational types; mangrove, fresh water swamps and hintherland communities were used to evaluate sea level fluctuations with respect to sediments deposited in the basins and linked with a particular depositional system tract. Amama-1 recorded 4 maximum flooding surface(MFS) at depth 165-1829, dated b/w 61ma-76ma and three sequence boundary(SB) at depth1048m - 1533m and 1581 dated b/w 634m - 1387m, dated 69.5ma - 82ma and four sequence boundary(SB) at 552m-876m, dated 68ma-77.5ma respectively. The application of ecostratigraphic description is characterised by the prominent expansion of the hinterland component consisting of the Mangrove to Lowland Rainforest and Afromontane – Savannah vegetation.Keywords: foraminifera, palynomorphs, Campanian, Maastritchian, ecostratigraphic, Anambra
Procedia PDF Downloads 251205 High Impact Ecostratigraphic and Biostratigrapgic Study of Amama-1 and Bara-1 Wells in Parts of Anambra Basin
Authors: J. O. Njoku, G. C. Soronnadi-ononiwu, E. J. Acrra, C. C. Agoha, T. C. Anyawu
Abstract:
The High Impact Ecostratigraphic And Biostratigrapgic Study of parts of Anambra basin was carried out using samples from two exploration wells (Amama-1 and Bara-1), Amama-1 (219M–1829M) and Bara-1 (317M-1594M). Palynological and Paleontological analyses were carried out on 100 ditch cutting samples. The faunal and floral succession were of terrestrial and marine origin as described and logged. The well penetrated four stratigraphic units in Anambra Basin (the Nkporo, Mamu, Ajali and Nsukka) the wells yielded well preserved formanifera and palynormorphs. The well yielded 53 species of foram and 69 species of palynomorphs, with 12 genera Bara-1 (25 Species of foram and 101 species of palynormorphs). Amama-1permitted the recognition of 21 genera with 31 formainiferal assemblage zones, 32 pollen and 37 spores assemblage zones, and dinoflagellate cyst, biozonation, ranging from late Campanian – early Paleocene. Bara-1 yielded (60 pollen, 41 spore assemblage zone and 18 dinoflagellate cyst).The zones, in stratigraphically ascending order for the foraminifera and palynomorphs are as follows. Amama Biozone A-Globotruncanella havanensis zone: Late Campanian –Maastrichtian (695 – 1829m) Biozone B-Morozovella velascoensis zone: Early Paleocene(165–695m) Bara-1 Biozone A-Globotruncanella havanensis zone: Late Campanian(1512m) Biozone B-Bolivina afra, B. explicate zone: Maastrichtian (634–1204m) Biozone C - Indeterminate (305 – 634m) palynomorphs Amama-1 A.Ctenolophonidites costatus zone:Early Maastrichtian (1829m) B-Retidiporites miniporatus Zone: Late Maastrichtian (1274m) Constructipollenites ineffectus Zone: Early Paleocene(695m) Bara-1 Droseridites senonicus Zone: Late Campanian (994– 1600m) B. Ctenolophonidites costatus Zone: Early Maastrichtian (713–994m) C. Retidiporites miniporatus Zone: Late Maastrichtian (305 –713m) The paleo – environment of deposition were determined to range from non-marine to outer netritic. A detailed categorization of the palynormorphs into terrestrially derived palynormorphs and marine derived palynormorphs based on the distribution of three broad vegetational types; mangrove, fresh water swamps and hintherland communities were used to evaluate sea level fluctuations with respect to sediments deposited in the basins and linked with a particular depositional system tract. Amama-1 recorded 4 maximum flooding surface(MFS) at depth 165-1829, dated b/w 61ma-76ma and three sequence boundary(SB) at depth1048m - 1533m and 1581 dated b/w 634m - 1387m, dated 69.5ma - 82ma and four sequence boundary(SB) at 552m-876m, dated 68ma-77.5ma respectively. The application of ecostratigraphic description is characterised by the prominent expansion of the hinterland component consisting of the Mangrove to Lowland Rainforest and Afromontane – Savannah vegetation.Keywords: formanifera, palynomorphs. Campanian, Maastritchian, Ecostratigraphic, Anambra
Procedia PDF Downloads 181204 A Robust Implementation of a Building Resources Access Rights Management System
Authors: Eugen Neagoe, Victor Balanica
Abstract:
A Smart Building Controller (SBC) is a server software that offers secured access to a pool of building specific resources, executes monitoring tasks and performs automatic administration of a building, thus optimizing the exploitation cost and maximizing comfort. This paper brings to discussion the issues that arise with the secure exploitation of the SBC administered resources and proposes a technical solution to implement a robust secure access system based on roles, individual rights and privileges (special rights).Keywords: smart building controller, software security, access rights, access authorization
Procedia PDF Downloads 4401203 Trends of Conservation and Development in Mexican Biosphere Reserves: Spatial Analysis and Linear Mixed Model
Authors: Cecilia Sosa, Fernanda Figueroa, Leonardo Calzada
Abstract:
Biosphere reserves (BR) are considered as the main strategy for biodiversity and ecosystems conservation. Mexican BR are mainly inhabited by rural communities who strongly depend on forests and their resources. Even though the dual objective of conservation and development has been sought in BR, land cover change is a common process in these areas, while most rural communities are highly marginalized, partly as a result of restrictions imposed by conservation to the access and use of resources. Achieving ecosystems conservation and social development face serious challenges. Factors such as financial support for development projects (public/private), environmental conditions, infrastructure and regional economic conditions might influence both land use change and wellbeing. Examining the temporal trends of conservation and development in BR is central for the evaluation of outcomes for these conservation strategies. In this study, we analyzed changes in primary vegetation cover (as a proxy for conservation) and the index of marginalization (as a proxy for development) in Mexican BR (2000-2015); we also explore the influence of various factors affecting these trends, such as conservation-development projects financial support (public or private), geographical distribution in ecoregions (as a proxy for shared environmental conditions) and in economic zones (as a proxy for regional economic conditions). We developed a spatial analysis at the municipal scale (2,458 municipalities nationwide) in ArcGIS, to obtain road densities, geographical distribution in ecoregions and economic zones, the financial support received, and the percent of municipality area under protection by protected areas and, particularly, by BR. Those municipalities with less than 25% of area under protection were regarded as part of the protected area. We obtained marginalization indexes for all municipalities and, using MODIS in Google Earth Engine, the number of pixels covered by primary vegetation. We used a linear mixed model in RStudio for the analysis. We found a positive correlation between the marginalization index and the percent of primary vegetation cover per year (r=0.49-0.5); i.e., municipalities with higher marginalization also show higher percent of primary vegetation cover. Also, those municipalities with higher area under protection have more development projects (r=0.46) and some environmental conditions were relevant for percent of vegetation cover. Time, economic zones and marginalization index were all important. Time was particularly, in 2005, when both marginalization and deforestation decreased. Road densities and financial support for conservation-development projects were irrelevant as factors in the general correlation. Marginalization is still being affected by the conservation strategies applied in BR, even though that this management category considers both conservation and development of local communities as its objectives. Our results suggest that roads densities and support for conservation-development projects have not been a factor of poverty alleviation. As better conservation is being attained in the most impoverished areas, we face the dilemma of how to improve wellbeing in rural communities under conservation, since current strategies have not been able to leave behind the conservation-development contraposition.Keywords: deforestation, local development, marginalization, protected areas
Procedia PDF Downloads 1361202 3D Modeling of Flow and Sediment Transport in Tanks with the Influence of Cavity
Authors: A. Terfous, Y. Liu, A. Ghenaim, P. A. Garambois
Abstract:
With increasing urbanization worldwide, it is crucial to sustainably manage sediment flows in urban networks and especially in stormwater detention basins. One key aspect is to propose optimized designs for detention tanks in order to best reduce flood peak flows and in the meantime settle particles. It is, therefore, necessary to understand complex flows patterns and sediment deposition conditions in stormwater detention basins. The aim of this paper is to study flow structure and particle deposition pattern for a given tank geometry in view to control and maximize sediment deposition. Both numerical simulation and experimental works were done to investigate the flow and sediment distribution in a storm tank with a cavity. As it can be indicated, the settle distribution of the particle in a rectangular tank is mainly determined by the flow patterns and the bed shear stress. The flow patterns in a rectangular tank differ with different geometry, entrance flow rate and the water depth. With the changing of flow patterns, the bed shear stress will change respectively, which also play an influence on the particle settling. The accumulation of the particle in the bed changes the conditions at the bottom, which is ignored in the investigations, however it worth much more attention, the influence of the accumulation of the particle on the sedimentation should be important. The approach presented here is based on the resolution of the Reynolds averaged Navier-Stokes equations to account for turbulent effects and also a passive particle transport model. An analysis of particle deposition conditions is presented in this paper in terms of flow velocities and turbulence patterns. Then sediment deposition zones are presented thanks to the modeling with particle tracking method. It is shown that two recirculation zones seem to significantly influence sediment deposition. Due to the possible overestimation of particle trap efficiency with standard wall functions and stick conditions, further investigations seem required for basal boundary conditions based on turbulent kinetic energy and shear stress. These observations are confirmed by experimental investigations processed in the laboratory.Keywords: storm sewers, sediment deposition, numerical simulation, experimental investigation
Procedia PDF Downloads 3251201 Implication of Built-Up Area, Vegetation, and Motorized Vehicles to Urban Microclimate in Bandung City Center
Authors: Ira Irawati, Muhammad Rangga Sururi
Abstract:
The expansion of built-up areas in many cities, particularly, as the consequences of urbanization process, is a common phenomenon in our contemporary world. As happened in many cities in developing world, this horizontal expansion let only a handful size of the area left for green open spaces, creating an extreme unbalance between built-up and green spaces. Combined with the high density and variety of human activities with its transportation modes; a process of urban heat island will occur, resulting in an increase in air temperature. This is one of the indicators of decreasing of the quality of urban microclimate. This paper will explore the effect of several variables of built-up areas and open spaces to the increase of air temperature using multiple linear regression analysis. We selected 11 zones within the radius of 1 km in Inner Bandung city center, and each zones measured within 300 m radius to represent the variety of land use, as well as the composition of buildings and green open spaces. By using a quantitative method which is multiple linear regression analysis, six dependent variables which are a) tree density-x1, b) shade level of tree-x2, c) surface area of buildings’ side which are facing west and east-x3, d) surface area of building side material-x4, e) surface area of pathway material, and f) numbers of motorized vehicles-x6; are calculated to find those influence to the air temperature as an independent variable-y. Finally, the relationship between those variables shows in this equation: y = 30.316 - 3.689 X1 – 6.563 X2 + 0.002 X3 – 2,517E6 X4 + 1.919E-9 X5 + 1.952E-4 X6. It shows that the existence of vegetation has a great impact on lowering temperature. In another way around, built up the area and motorized vehicles would increase the temperature. However, one component of built up area, the surface area of buildings’ sides which are facing west and east, has different result due to the building material is classified in low-middle heat capacity.Keywords: built-up area, microclimate, vehicles, urban heat island, vegetation
Procedia PDF Downloads 2591200 Investigating Effects of Vehicle Speed and Road PSDs on Response of a 35-Ton Heavy Commercial Vehicle (HCV) Using Mathematical Modelling
Authors: Amal G. Kurian
Abstract:
The use of mathematical modeling has seen a considerable boost in recent times with the development of many advanced algorithms and mathematical modeling capabilities. The advantages this method has over other methods are that they are much closer to standard physics theories and thus represent a better theoretical model. They take lesser solving time and have the ability to change various parameters for optimization, which is a big advantage, especially in automotive industry. This thesis work focuses on a thorough investigation of the effects of vehicle speed and road roughness on a heavy commercial vehicle ride and structural dynamic responses. Since commercial vehicles are kept in operation continuously for longer periods of time, it is important to study effects of various physical conditions on the vehicle and its user. For this purpose, various experimental as well as simulation methodologies, are adopted ranging from experimental transfer path analysis to various road scenario simulations. To effectively investigate and eliminate several causes of unwanted responses, an efficient and robust technique is needed. Carrying forward this motivation, the present work focuses on the development of a mathematical model of a 4-axle configuration heavy commercial vehicle (HCV) capable of calculating responses of the vehicle on different road PSD inputs and vehicle speeds. Outputs from the model will include response transfer functions and PSDs and wheel forces experienced. A MATLAB code will be developed to implement the objectives in a robust and flexible manner which can be exploited further in a study of responses due to various suspension parameters, loading conditions as well as vehicle dimensions. The thesis work resulted in quantifying the effect of various physical conditions on ride comfort of the vehicle. An increase in discomfort is seen with velocity increase; also the effect of road profiles has a considerable effect on comfort of the driver. Details of dominant modes at each frequency are analysed and mentioned in work. The reduction in ride height or deflection of tire and suspension with loading along with load on each axle is analysed and it is seen that the front axle supports a greater portion of vehicle weight while more of payload weight comes on fourth and third axles. The deflection of the vehicle is seen to be well inside acceptable limits.Keywords: mathematical modeling, HCV, suspension, ride analysis
Procedia PDF Downloads 2591199 Control Algorithm for Home Automation Systems
Authors: Marek Długosz, Paweł Skruch
Abstract:
One of purposes of home automation systems is to provide appropriate comfort to the users by suitable air temperature control and stabilization inside the rooms. The control of temperature level is not a simple task and the basic difficulty results from the fact that accurate parameters of the object of control, that is a building, remain unknown. Whereas the structure of the model is known, the identification of model parameters is a difficult task. In this paper, a control algorithm allowing the present temperature to be reached inside the building within the specified time without the need to know accurate parameters of the building itself is presented.Keywords: control, home automation system, wireless networking, automation engineering
Procedia PDF Downloads 6181198 GIS and Remote Sensing Approach in Earthquake Hazard Assessment and Monitoring: A Case Study in the Momase Region of Papua New Guinea
Authors: Tingneyuc Sekac, Sujoy Kumar Jana, Indrajit Pal, Dilip Kumar Pal
Abstract:
Tectonism induced Tsunami, landslide, ground shaking leading to liquefaction, infrastructure collapse, conflagration are the common earthquake hazards that are experienced worldwide. Apart from human casualty, the damage to built-up infrastructures like roads, bridges, buildings and other properties are the collateral episodes. The appropriate planning must precede with a view to safeguarding people’s welfare, infrastructures and other properties at a site based on proper evaluation and assessments of the potential level of earthquake hazard. The information or output results can be used as a tool that can assist in minimizing risk from earthquakes and also can foster appropriate construction design and formulation of building codes at a particular site. Different disciplines adopt different approaches in assessing and monitoring earthquake hazard throughout the world. For the present study, GIS and Remote Sensing potentials were utilized to evaluate and assess earthquake hazards of the study region. Subsurface geology and geomorphology were the common features or factors that were assessed and integrated within GIS environment coupling with seismicity data layers like; Peak Ground Acceleration (PGA), historical earthquake magnitude and earthquake depth to evaluate and prepare liquefaction potential zones (LPZ) culminating in earthquake hazard zonation of our study sites. The liquefaction can eventuate in the aftermath of severe ground shaking with amenable site soil condition, geology and geomorphology. The latter site conditions or the wave propagation media were assessed to identify the potential zones. The precept has been that during any earthquake event the seismic wave is generated and propagates from earthquake focus to the surface. As it propagates, it passes through certain geological or geomorphological and specific soil features, where these features according to their strength/stiffness/moisture content, aggravates or attenuates the strength of wave propagation to the surface. Accordingly, the resulting intensity of shaking may or may not culminate in the collapse of built-up infrastructures. For the case of earthquake hazard zonation, the overall assessment was carried out through integrating seismicity data layers with LPZ. Multi-criteria Evaluation (MCE) with Saaty’s Analytical Hierarchy Process (AHP) was adopted for this study. It is a GIS technology that involves integration of several factors (thematic layers) that can have a potential contribution to liquefaction triggered by earthquake hazard. The factors are to be weighted and ranked in the order of their contribution to earthquake induced liquefaction. The weightage and ranking assigned to each factor are to be normalized with AHP technique. The spatial analysis tools i.e., Raster calculator, reclassify, overlay analysis in ArcGIS 10 software were mainly employed in the study. The final output of LPZ and Earthquake hazard zones were reclassified to ‘Very high’, ‘High’, ‘Moderate’, ‘Low’ and ‘Very Low’ to indicate levels of hazard within a study region.Keywords: hazard micro-zonation, liquefaction, multi criteria evaluation, tectonism
Procedia PDF Downloads 2661197 Will My Home Remain My Castle? Tenants’ Interview Topics regarding an Eco-Friendly Refurbishment Strategy in a Neighborhood in Germany
Authors: Karin Schakib-Ekbatan, Annette Roser
Abstract:
According to the Federal Government’s plans, the German building stock should be virtually climate neutral by 2050. Thus, the “EnEff.Gebäude.2050” funding initiative was launched, complementing the projects of the Energy Transition Construction research initiative. Beyond the construction and renovation of individual buildings, solutions must be found at the neighborhood level. The subject of the presented pilot project is a building ensemble from the Wilhelminian period in Munich, which is planned to be refurbished based on a socially compatible, energy-saving, innovative-technical modernization concept. The building ensemble, with about 200 apartments, is part of the building cooperative. To create an optimized network and possible synergies between researchers and projects of the funding initiative, a Scientific Accompanying Research was established for cross-project analyses of findings and results in order to identify further research needs and trends. Thus, the project is characterized by an interdisciplinary approach that combines constructional, technical, and socio-scientific expertise based on a participatory understanding of research by involving the tenants at an early stage. The research focus is on getting insights into the tenants’ comfort requirements, attitudes, and energy-related behaviour. Both qualitative and quantitative methods are applied based on the Technology-Acceptance-Model (TAM). The core of the refurbishment strategy is a wall heating system intended to replace conventional radiators. A wall heating provides comfortable and consistent radiant heat instead of convection heat, which often causes drafts and dust turbulence. Besides comfort and health, the advantage of wall heating systems is an energy-saving operation. All apartments would be supplied by a uniform basic temperature control system (around perceived room temperature of 18 °C resp. 64,4 °F), which could be adapted to individual preferences via individual heating options (e. g. infrared heating). The new heating system would affect the furnishing of the walls, in terms of not allowing the wall surface to be covered too much with cupboards or pictures. Measurements and simulations of the energy consumption of an installed wall heating system are currently being carried out in a show apartment in this neighborhood to investigate energy-related, economical aspects as well as thermal comfort. In March, interviews were conducted with a total of 12 people in 10 households. The interviews were analyzed by MAXQDA. The main issue of the interview was the fear of reduced self-efficacy within their own walls (not having sufficient individual control over the room temperature or being very limited in furnishing). Other issues concerned the impact that the construction works might have on their daily life, such as noise or dirt. Despite their basically positive attitude towards a climate-friendly refurbishment concept, tenants were very concerned about the further development of the project and they expressed a great need for information events. The results of the interviews will be used for project-internal discussions on technical and psychological aspects of the refurbishment strategy in order to design accompanying workshops with the tenants as well as to prepare a written survey involving all households of the neighbourhood.Keywords: energy efficiency, interviews, participation, refurbishment, residential buildings
Procedia PDF Downloads 1261196 Optimization of Sucrose Concentration, PH Level and Inoculum Size for Callus Proliferation and Anti-bacterial Potential of Stevia Rebaudiana Bertoni
Authors: Inayat Ur Rahman Arshad
Abstract:
Stevia rebaudiana B. is a shrubby perennial herb of Asteraceae family that possesses the unique ability of accumulative non caloric sweet Steviol Glycosides (SGs). The purpose of the study is to optimize sugar concentration, pH level and inoculum size for inducing the callus with optimum growth and efficient antibacterial potential. Three different experiments were conducted in which Callus explant from three-months-old already established callus of Stevia reabudiana of four different sizes were inoculated on Murashige and Skoog (MS) basal medium supplemented with five different sucrose concentration and pH adjusted at four different levels. Maximum callus induction 100, 87.5 and 85.33% was resulted in the medium supplemented with 30g/l sucrose, pH maintained at 5.5 and inoculated with 1.25g inoculum respectively. Similarly, the highest fresh weight 65.00, 75.50 and 50.53g/l were noted in medium fortified with 40g/l sucrose, inoculated 1.25g inoculum and 6.0 pH level respectively. However, the callus developed in medium containing 50g/l sucrose found highly antibacterial potent with 27.3 and 26.5mm inhibition zone against P. vulgaris and B. subtilize respectively. Similarly, the callus grown on medium inoculated with 1.00g inoculum resulted in maximum antibacterial potential against S. aureus and P. vulgaris with 25 and 23.72mm inhibition zones respectively. However, in the case of pH levels the medium maintained at 6.5pH showed maximum antibacterial activity against P. vulgaris, B.subtilis and E.coli with 27.9, 25 and 23.72mm respectively. The ethyl acetate extract of Stevia callus and leaves did not show antibacterial potential against Xanthomonas campestris and Clavebactor michiganensis. In the entire experiment the standard antibacterial agent Streptomycin showed the highest inhibition zones from the rest of the callus extract, however the pure DMSO (Dimethyl Sulfoxide) caused no inhibitory zone against any bacteria. From these findings it is concluded that among various levels sucrose at the rate of 40g L-1, pH 6.0 and inoculums 0.75g was found best for most of the growth and quality attributes including fresh weight, dry weight and antibacterial activities and therefore can be recommended for callus proliferation and antibacterial potential of Stevia rebaudianaKeywords: Steviol Glycosides, Skoog, Murashige, Clavebactor michiganensis
Procedia PDF Downloads 871195 A Designing 3D Model: Castle of the Mall-Dern
Authors: Nanadcha Sinjindawong
Abstract:
This article discusses the design process of a community mall called Castle of The Mall-dern. The concept behind this mall is to combine elements of a medieval castle with modern architecture. The author aims to create a building that fits into the surroundings while also providing users with the vibes of the ancient era. The total area used for the mall is 4,000 square meters, with three floors. The first floor is 1,500 square meters, the second floor is 1,750 square meters, and the third floor is 750 square meters. Research Aim: The aim of this research is to design a community mall that sells ancient clothes and accessories, and to combine sustainable architectural design with the ideas of ancient architecture in an urban area with convenient transportation. Methodology: The research utilizes qualitative research methods in architectural design. The process begins with calculating the given area and dividing it into different zones. The author then sketches and draws the plan of each floor, adding the necessary rooms based on the floor areas mentioned earlier. The program "SketchUp" is used to create an online 3D model of the community mall, and a physical model is built for presentation purposes on A1 paper, explaining all the details. Findings: The result of this research is a community mall with various amenities. The first floor includes retail shops, clothing stores, a food center, and a service zone. Additionally, there is an indoor garden with a fountain and a tree for relaxation. The second and third floors feature a void in the middle, with a few stores, cafes, restaurants, and studios on the second floor. The third floor is home to the administration and security control room, as well as a community gathering area designed as a public library with a café inside. Theoretical Importance: This research contributes to the field of sustainable architectural design by combining ancient architectural ideas with modern elements. It showcases the potential for creating buildings that blend historical aesthetics with contemporary functionality. Data Collection and Analysis Procedures: The data for this research is collected through a combination of area calculation, sketching, and building a 3D model. The analysis involves evaluating the design based on the allocated area, zoning, and functional requirements for a community mall. Question Addressed: The research addresses the question of how to design a community mall with a theme of ancient Medieval and Victorian eras. It explores how to combine sustainable architectural design principles with historical aesthetics to create a functional and visually appealing space. Conclusion: In conclusion, this research successfully designs a community mall called “Castle of The Mall-dern” that incorporates elements of Medieval and Victorian architecture. The building encompasses various zones, including retail shops, restaurants, community gathering areas, and service zones. It also features an interior garden and a public library within the mall. The research contributes to the field of sustainable architectural design by showcasing the potential for combining ancient architectural ideas with modern elements in an urban setting.Keywords: 3D model, community mall, modern architecture, medieval architecture
Procedia PDF Downloads 1071194 Subtidal Crabs of Oman Sea: New Collections and Biogeographic Considerations
Authors: Negar Ghotbeddin, Seied Mohammad Reza Fatemi, Tooraj Valinassab
Abstract:
The samplings were carried out at 8 stations (Govatr, Pasabandar, Beriss, Ramin, Chabahar, Pozm, Gordim, and Meidani) in subtidal zones of Oman Sea during the year 2009-2010. The specimens were collected by trawl net and preserved in 70% alcohol. A total of 23 species belonged to 9 families and 15 genera were caught. The results of the present study revealed that families Portunidae had the highest species enriched with 9 species. Most of the species had high distribution in the west Indian Ocean (69.56%) and 8.69% of species were endemic. Almost species were similar to those found in the Persian Gulf.Keywords: Brachyura, biogeography, subtidal, Oman Sea
Procedia PDF Downloads 5881193 Study on Natural Light Distribution Inside the Room by Using Sudare as an Outside Horizontal Blind in Tropical Country of Indonesia
Authors: Agus Hariyadi, Hiroatsu Fukuda
Abstract:
In tropical country like Indonesia, especially in Jakarta, most of the energy consumption on building is for the cooling system, the second one is from lighting electric consumption. One of the passive design strategy that can be done is optimizing the use of natural light from the sun. In this area, natural light is always available almost every day around the year. Natural light have many effect on building. It can reduce the need of electrical lighting but also increase the external load. Another thing that have to be considered in the use of natural light is the visual comfort from occupant inside the room. To optimize the effectiveness of natural light need some modification of façade design. By using external shading device, it can minimize the external load that introduces into the room, especially from direct solar radiation which is the 80 % of the external energy load that introduces into the building. It also can control the distribution of natural light inside the room and minimize glare in the perimeter zone of the room. One of the horizontal blind that can be used for that purpose is Sudare. It is traditional Japanese blind that have been used long time in Japanese traditional house especially in summer. In its original function, Sudare is used to prevent direct solar radiation but still introducing natural ventilation. It has some physical characteristics that can be utilize to optimize the effectiveness of natural light. In this research, different scale of Sudare will be simulated using EnergyPlus and DAYSIM simulation software. EnergyPlus is a whole building energy simulation program to model both energy consumption—for heating, cooling, ventilation, lighting, and plug and process loads—and water use in buildings, while DAYSIM is a validated, RADIANCE-based daylighting analysis software that models the annual amount of daylight in and around buildings. The modelling will be done in Ladybug and Honeybee plugin. These are two open source plugins for Grasshopper and Rhinoceros 3D that help explore and evaluate environmental performance which will directly be connected to EnergyPlus and DAYSIM engines. Using the same model will maintain the consistency of the same geometry used both in EnergyPlus and DAYSIM. The aims of this research is to find the best configuration of façade design which can reduce the external load from the outside of the building to minimize the need of energy for cooling system but maintain the natural light distribution inside the room to maximize the visual comfort for occupant and minimize the need of electrical energy consumption.Keywords: façade, natural light, blind, energy
Procedia PDF Downloads 3451192 Dimensions of Public Spaces in Indian Market Places Feelings through Human Senses
Authors: Piyush Hajela
Abstract:
Public spaces in Indian market places are vibrant, colorful and carry latent dimensions that make them attractive and popular gathering spaces. These markets satisfy the household needs of the people and also their social, cultural and traditional aspirations. Going to a market place for shopping in India is a great source of entertainment for the people. They would love to spend as much time as possible and stay for longer durations than otherwise required. It is this desire of the people that generates public spaces. Much of these public spaces emerge as squares, plazas, corners of varied shapes and sizes at different locations, and yet provide a conducive environment. Such public spaces grow organically and are discovered by the people themselves. Indian markets serve people of different culture, religion, caste, age, gender which keeps them alive all the year round. Indian is a diverse country and this diversity is reflected clearly in the market places. They hold the people together and promote harmony across cultures. Free access to these market places makes them magnets for social interaction. Public spaces are spread across a city and more or less have established their existence and prominence in a social set up. While few of them are created, others are discovered by the people themselves in their constant search for desirable interactive public spaces. These are the most sought after gathering spaces that have the quality of promoting social interaction, providing free accessibility, provide desirable scale etc. The paper aims at identifying these freely accessible public spaces and the dimensions within it that make these public spaces hold the people for significant duration of time. The dimensions present shall be judged through collective response of human senses in form of safety, comfort and so on through the expressions of the participants. The aim therefore would be to trace the freely accessible public spaces emerged in Indian markets and evaluate them for human response and behavior. The hierarchy of market places in the city of Bhopal is well established as, city center level, sub city-center level, community level, local and convenient level market places. While many city-centers are still referred to as the old or traditional or the core area of the city, the others are part of the planned city. These different levels of market places are studied for emerged public spaces. These emerged public spaces are then documented in detail for unveiling the dimensions they offer through, photographs, visual observations, questionnaires and response of the participants of these public spaces.Keywords: human comfort, enclosure, safety, social interaction
Procedia PDF Downloads 4171191 The Impact of Water Reservoirs on Biodiversity and Food Security and the Creation of Adaptation Mechanisms
Authors: Inom S. Normatov, Abulqosim Muminov, Parviz I. Normatov
Abstract:
Problems of food security and the preservation of reserved zones in the region of Central Asia under the conditions of the climate change induced by the placement and construction of large reservoirs are considered. The criteria for the optimum placement and construction of reservoirs that entail the minimum impact on the environment are established. The need for the accounting of climatic parameters is shown by the calculation of the water quantity required for the irrigation of agricultural lands.Keywords: adaptation, biodiversity, food security, water reservoir, risk
Procedia PDF Downloads 2561190 Dynamic Facades: A Literature Review on Double-Skin Façade with Lightweight Materials
Authors: Victor Mantilla, Romeu Vicente, António Figueiredo, Victor Ferreira, Sandra Sorte
Abstract:
Integrating dynamic facades into contemporary building design is shaping a new era of energy efficiency and user comfort. These innovative facades, often constructed using lightweight construction systems and materials, offer an opportunity to have a responsive and adaptive nature to the dynamic behavior of the outdoor climate. Therefore, in regions characterized by high fluctuations in daily temperatures, the ability to adapt to environmental changes is of paramount importance and a challenge. This paper presents a thorough review of the state of the art on double-skin facades (DSF), focusing on lightweight solutions for the external envelope. Dynamic facades featuring elements like movable shading devices, phase change materials, and advanced control systems have revolutionized the built environment. They offer a promising path for reducing energy consumption while enhancing occupant well-being. Lightweight construction systems are increasingly becoming the choice for the constitution of these facade solutions, offering benefits such as reduced structural loads and reduced construction waste, improving overall sustainability. However, the performance of dynamic facades based on low thermal inertia solutions in climatic contexts with high thermal amplitude is still in need of research since their ability to adapt is traduced in variability/manipulation of the thermal transmittance coefficient (U-value). Emerging technologies can enable such a dynamic thermal behavior through innovative materials, changes in geometry and control to optimize the facade performance. These innovations will allow a facade system to respond to shifting outdoor temperature, relative humidity, wind, and solar radiation conditions, ensuring that energy efficiency and occupant comfort are both met/coupled. This review addresses the potential configuration of double-skin facades, particularly concerning their responsiveness to seasonal variations in temperature, with a specific focus on addressing the challenges posed by winter and summer conditions. Notably, the design of a dynamic facade is significantly shaped by several pivotal factors, including the choice of materials, geometric considerations, and the implementation of effective monitoring systems. Within the realm of double skin facades, various configurations are explored, encompassing exhaust air, supply air, and thermal buffering mechanisms. According to the review places a specific emphasis on the thermal dynamics at play, closely examining the impact of factors such as the color of the facade, the slat angle's dimensions, and the positioning and type of shading devices employed in these innovative architectural structures.This paper will synthesize the current research trends in this field, with the presentation of case studies and technological innovations with a comprehensive understanding of the cutting-edge solutions propelling the evolution of building envelopes in the face of climate change, namely focusing on double-skin lightweight solutions to create sustainable, adaptable, and responsive building envelopes. As indicated in the review, flexible and lightweight systems have broad applicability across all building sectors, and there is a growing recognition that retrofitting existing buildings may emerge as the predominant approach.Keywords: adaptive, control systems, dynamic facades, energy efficiency, responsive, thermal comfort, thermal transmittance
Procedia PDF Downloads 801189 Fault Diagnosis and Fault-Tolerant Control of Bilinear-Systems: Application to Heating, Ventilation, and Air Conditioning Systems in Multi-Zone Buildings
Authors: Abderrhamane Jarou, Dominique Sauter, Christophe Aubrun
Abstract:
Over the past decade, the growing demand for energy efficiency in buildings has attracted the attention of the control community. Failures in HVAC (heating, ventilation and air conditioning) systems in buildings can have a significant impact on the desired and expected energy performance of buildings and on the user's comfort as well. FTC is a recent technology area that studies the adaptation of control algorithms to faulty operating conditions of a system. The application of Fault-Tolerant Control (FTC) in HVAC systems has gained attention in the last two decades. The objective is to maintain the variations in system performance due to faults within an acceptable range with respect to the desired nominal behavior. This paper considers the so-called active approach, which is based on fault and identification scheme combined with a control reconfiguration algorithm that consists in determining a new set of control parameters so that the reconfigured performance is "as close as possible, "in some sense, to the nominal performance. Thermal models of buildings and their HVAC systems are described by non-linear (usually bi-linear) equations. Most of the works carried out so far in FDI (fault diagnosis and isolation) or FTC consider a linearized model of the studied system. However, this model is only valid in a reduced range of variation. This study presents a new fault diagnosis (FD) algorithm based on a bilinear observer for the detection and accurate estimation of the magnitude of the HVAC system failure. The main contribution of the proposed FD algorithm is that instead of using specific linearized models, the algorithm inherits the structure of the actual bilinear model of the building thermal dynamics. As an immediate consequence, the algorithm is applicable to a wide range of unpredictable operating conditions, i.e., weather dynamics, outdoor air temperature, zone occupancy profile. A bilinear fault detection observer is proposed for a bilinear system with unknown inputs. The residual vector in the observer design is decoupled from the unknown inputs and, under certain conditions, is made sensitive to all faults. Sufficient conditions are given for the existence of the observer and results are given for the explicit computation of observer design matrices. Dedicated observer schemes (DOS) are considered for sensor FDI while unknown input bilinear observers are considered for actuator or system components FDI. The proposed strategy for FTC works as follows: At a first level, FDI algorithms are implemented, making it also possible to estimate the magnitude of the fault. Once the fault is detected, the fault estimation is then used to feed the second level and reconfigure the control low so that that expected performances are recovered. This paper is organized as follows. A general structure for fault-tolerant control of buildings is first presented and the building model under consideration is introduced. Then, the observer-based design for Fault Diagnosis of bilinear systems is studied. The FTC approach is developed in Section IV. Finally, a simulation example is given in Section V to illustrate the proposed method.Keywords: bilinear systems, fault diagnosis, fault-tolerant control, multi-zones building
Procedia PDF Downloads 1721188 An Application-Based Indoor Environmental Quality (IEQ) Calculator for Residential Buildings
Authors: Kwok W. Mui, Ling T. Wong, Chin T. Cheung, Ho C. Yu
Abstract:
Based on an indoor environmental quality (IEQ) index established by previous work that indicates the overall IEQ acceptance from the prospect of an occupant in residential buildings in terms of four IEQ factors - thermal comfort, indoor air quality, visual and aural comforts, this study develops a user-friendly IEQ calculator for iOS and Android users to calculate the occupant acceptance and compare the relative performance of IEQ in apartments. The calculator allows the prediction of the best IEQ scenario on a quantitative scale. Any indoor environments under the specific IEQ conditions can be benchmarked against the predicted IEQ acceptance range. This calculator can also suggest how to achieve the best IEQ acceptance among a group of residents.Keywords: calculator, indoor environmental quality (IEQ), residential buildings, 5-star benchmarks
Procedia PDF Downloads 4741187 Community-Based Palliative Care for Patients with Cerebral Palsy and Developmental Disabilities
Authors: Elizabeth Grier, Meg Gemmill, Mary Martin, Leora Reiter, Herman Tang, Alexandra Donaldson, Isis Lunsky, Mia Wu
Abstract:
Background: Individuals with Cerebral Palsy (CP) and/or IDD face numerous physical and mental health challenges, including difficulty accessing effective palliative care. The aim of this study is to assess the knowledge and comfort of healthcare providers in providing community-based palliative care for patients with Cerebral Palsy (CP) and severe to profound Intellectual and Developmental Disabilities (IDD). Methods: This study includes a mixed methods approach obtaining both quantitative and qualitative data. Quantitative data from palliative care practitioners was obtained through an online survey assessing comfort in symptom management, grief assessment, and goals of care discussion. This survey was distributed to physicians and allied health practitioners across Canada through the College of Family Physicians of Canada Member Interest Groups for Palliative Care and for IDD. Survey results guided the development of a semi-structured interview template, which was used to conduct a focus group on the same topic. Participants were four palliative care providers (3 physicians and one spiritual care practitioner). The focus group transcript is currently undergoing thematic analysis using NVivo 12 software. Results: 57 palliative care practitioners completed the survey. 87% of participants indicated they have provided palliative care services for persons with CP and/or IDD. Findings suggest practitioners are somewhat confident in identifying specific physical symptoms (dyspnea, pressure ulcers) but less confident in identifying physical/emotional pain, addressing grief, and prognosticating life expectancy in this population. 54% of responses indicated they had little/no training on palliating those with CP or IDD, and 45% somewhat or strongly disagree members of their profession can manage symptoms for this population. Focus group analysis is underway, and results will be available at the time of the poster presentation. Conclusion: Persons with CP and IDD are more likely to experience severe health inequities when accessing palliative care. Results of this study suggest further education is needed for palliative care professionals to address the barriers and challenges in providing palliative care to this patient population.Keywords: palliative care, symptom management, health equity, community healthcare, intellectual and developmental disabilities
Procedia PDF Downloads 1421186 Knowledge about Dementia: Why Should Family Caregivers Know that Dementia is a Terminal Disease?
Authors: Elzbieta Sikorska-Simmons
Abstract:
Dementia is a progressive terminal disease. Despite this recognition, research shows that most family caregivers do not know it, and it is unclear how this knowledge affects the quality of patient care. The aim of this qualitative study of 20 family caregivers for patients with advanced dementia is to examine how the caregiver's knowledge about dementia affects the quality of patient care in the context of healthcare decision-making, advanced care planning, and access to adequate support systems. Knowledge about dementia implies family caregivers' understanding of dementia trajectories, common symptoms/complications, and alternative treatment options (e.g., comfort feeding versus tube feeding). Data were collected in semi-structured interviews with 20 family caregivers. The interviews were conducted in person by the author and designed to elicit rich descriptions of family caregivers' experiences with healthcare decision-making and the management of common symptoms/complications of end-stage dementia as patient healthcare proxies. The study findings suggest that caregivers who recognize that dementia is a terminal disease are less likely to opt for life-extending treatments during the advanced stages. They are also more likely to seek palliative/hospice care, and consequently, they are better able to avoid unnecessary hospitalizations or medical procedures. For example, those who know that dementia is a terminal disease tend to opt for "comfort feeding" rather than "tube feeding" in managing the swallowing difficulties that accompany advanced dementia. In the context of advance care planning, family caregivers who know that dementia is a terminal disease tend to have more meaningful advance directives (e.g., Power of Attorney and Do Not Resuscitate orders). They are better prepared to anticipate common problems and pursue treatments that foster the best quality of patient life and care. Greater knowledge about advanced dementia helps them make more informed decisions that focus on enhancing the quality of patient life rather than just survival. In addition, those who know that dementia is a terminal disease are more likely to establish adequate support systems to help them cope with the complex demands of caregiving. For example, they are more likely to seek dementia-oriented primary care programs that offer house visits or respite services. Based on the study findings, knowledge about dementia as a terminal disease is critical in the optimal management of patient care needs and the establishment of adequate support systems. More research is needed to better understand what caregivers need to know to better prepare them for the complex demands of dementia caregiving.Keywords: dementia education, family caregiver, management of dementia, quality of care
Procedia PDF Downloads 1001185 Feasibility and Energy Efficiency Analysis of Chilled Water Radiant Cooling System of Office Apartment in Nigeria’s Tropical Climate City
Authors: Rasaq Adekunle Olabomi
Abstract:
More than 30% of the global building energy consumption is attributed to heating, ventilation and air-conditioning (HVAC) due to increasing urbanization and the need for more personal comfort. While heating is predominant in the temperate regions (especially during winter), comfort cooling is constantly needed in tropical regions such as Nigeria. This makes cooling a major contributor to the peak electrical load in the tropics. Meanwhile, the high solar energy availability in the tropical climate region presents a higher application potentials for solar thermal cooling systems; more so, the need for cooling mostly coincides with the solar energy availability. In addition to huge energy consumption, conventional (compressor type) air-conditioning systems mostly use refrigerants that are regarded as environmental unfriendly because of their ozone depletion potentials; this has made the alternative cooling systems to become popular in the present time. The better thermal capacity and less pumping power requirement of chilled water than chilled air has also made chilled water a preferred option over the chilled air cooling system. Radiant floor chilled water cooling is particularly is also considered suitable for spaces such as meeting room, seminar hall, auditorium, airport arrival and departure halls among others. This study did the analysis of the feasibility and energy efficiency of solar thermal chilled water for radiant flood cooling of an office apartment in a tropical climate city in Nigeria with a view to recommend its up-scaling. The analysis considered the weather parameters including available solar irradiance (kWh/m2-day) as well as the technical details of the solar thermal cooling systems to determine the feasibility. Project cost, its energy savings, emission reduction potentials and cost-to-benefits ration are used to analyze its energy efficiency as well as the viability of the cooling system. The techno-economic analysis of the proposed system, carried out using RETScreen software shows that its viability in but SWOT analysis of policy and institutional framework to promote solar energy utilization for the cooling systems shows weakness such as poor infrastructure and inadequate local capacity for technological development as major challenges.Keywords: cooling load, absorption cooling system, coefficient of performance, radiant floor, cost saving, emission reduction
Procedia PDF Downloads 241184 Softening Finishing: Teaching and Learning Materials
Authors: C.W. Kan
Abstract:
Softening applied on textile products based on several reasons. First, the synthetic detergent removes natural oils and waxes, thus lose the softness. Second, compensate the harsh handle of resin finishing. Also, imitate natural fibres and improve the comfort of fabric are the reasons to apply softening. There are different types of softeners for softening finishing of textiles, nonionic softener, anionic softener, cationic softener and silicone softener. The aim of this study is to illustrate the proper application of different softeners and their final softening effect in textiles. The results could also provide guidance note to the students in learning this topic. Acknowledgment: Authors would like to thank the financial support from the Hong Kong Polytechnic University for this work.Keywords: learning materials, softening, textiles, effect
Procedia PDF Downloads 217