Search results for: mechanical low back pain
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 6020

Search results for: mechanical low back pain

5570 Study on the Morphology and Dynamic Mechanical and Thermal Properties of HIPS/Graphene Nanocomposites

Authors: Amirhosein Rostampour, Mehdi Sharif

Abstract:

In this article, a series of high impact polystyrene/graphene (HIPS/Gr) nanocomposites were prepared by solution mixing method and their morphology and dynamic mechanical properties were investigated as a function of graphene content. SEM images and X-Ray diffraction data confirm that the graphene platelets are well dispersed in HIPS matrix for the nanocomposites with Gr contents up to 5.0 wt%. Mechanical properties analysis demonstrates that yielding strength and initial modulus of HIPS/Gr nanocomposites are highly improved with the increment of Gr content compared to pure HIPS.

Keywords: nanocomposite, graphene, dynamic mechanical properties, morphology

Procedia PDF Downloads 522
5569 Effects of EMS on Foot Drop Associated with Grade III Wound: A Case Report

Authors: Mirza Obaid Baig, MaimoonaYaqub

Abstract:

A 51 year old lady; known case of diabetes mellitus, post wound debridement i.e. 4 open wounds of grade III presented to us with foot drop, with prominent sensory deficit over right lower leg/foot i.e. 0 on Nottingham scale for impaired sensation, marked pedal edema and 5/10 – 6/10 pain on VAS during day and night respectively, Wounds were poorly granulated and foul smelling. Physiotherapy sessions were planned including twice a day electrical muscle stimulation sessions, strategies to decrease edema and improve muscle action which resulted in noticeable improvement in motor and sensory ability, pain levels, edema and psychological status of patient. Thus, this study gives evidence of the effect of Electrical muscle stimulation in grade III open wounds associated with motor/sensory weakness post-surgery.

Keywords: EMS, foot drop, grade III wound, diabetes mellitus

Procedia PDF Downloads 398
5568 Osteoarticular Manifestations and Abnormalities of Bone Metabolism in Celiac Disease

Authors: Soumaya Mrabet, Imen Akkari, Amira Atig, Elhem Ben Jazia

Abstract:

Introduction: Celiac disease (CD) is a chronic autoimmune inflammatory enteropathy caused by gluten. The clinical presentation is very variable. Malabsorption in the MC is responsible for an alteration of the bone metabolism. Our purpose is to study the osteoarticular manifestations related to this condition. Material and methods: It is a retrospective study of 41 cases of CD diagnosed on clinical, immunological, endoscopic and histological arguments, in the Internal Medicine and Gastroenterology Department of Farhat Hached Hospital between September 2005 and January 2016. Results: Osteoarticular manifestations were found in 9 patients (22%) among 41 patients presenting CD. These were 7 women and 2 men with an average age of 35.7 years (25 to 67 years). These manifestations were revelatory of CD in 3 cases. Abdominal pain and diarrhea were present in 6 cases. Inflammatory polyarthralgia of wrists and knees has been reported in 7 patients. Mechanical mono arthralgia was noted in 2 patients. Biological tests revealed microcytic anemia by iron deficiency in 7 cases, hypocalcemia in 5 cases, Hypophosphatemia in 3 cases and elevated alkaline phosphatases in 3 cases. Upper gastrointestinal endoscopy with duodenal biopsy found villous atrophy in all cases. In immunology, Anti-transglutaminase antibodies were positive in all patients, Anti-endomysium in 7 cases. Measurement of bone mineral density (BMD) by biphotonic X-ray absorptiometer with evaluation of the T-score and the Z-score was performed in Twenty patients (48.8%). It was normal in 7 cases (33%) and showed osteopenia in 5 patients (25%) and osteoporosis in 2 patients (10%). All patients were treated with a Gluten-free diet associated with vitamin D and calcium substitution in 5 cases. The evolution was favorable in all cases with reduction of bone pain and normalization of the phosphocalcic balance. Conclusion: The bone impact of CD is frequent but often asymptomatic. Patients with CD should be evaluated by the measurement of bone mineral density and monitored for calcium and vitamin D deficiencies.

Keywords: bone mineral density, celiac disease, osteoarticular manifestations, vitamin D and calcium

Procedia PDF Downloads 310
5567 Comparison of Virtual and Face to Face Training Program in Reducing Pain and Quality of Life of Female Students with Dysmenorrhea

Authors: Nilofar Mohammadi Ahvazi, Somayeh Ansari, Mohammad Hossein Haghighizadeh, Zahra Abbaspoor

Abstract:

Introduction: Dysmenorrhea is one of the common causes of decreased efficiency at work, education and decreased quality of life of women. The aim of this study was to compare virtual and face-to-face training programs in reducing pain and improving the quality of life of female students with primary dysmenorrhea in Ahvaz. Methods: In this quasi-experimental study, 112 female students living in the dormitories of Ahvaz University of Medical Sciences with moderate to severe primary dysmenorrhea were divided into two face-to-face and virtual groups using blocks of size 4. The educational intervention was carried out in two groups at a specific hour before the start of the first menstrual cycle. Data were collected with the help of a quality-of-life questionnaire (Sf-36), visual analog scale (VAS), and McGill questionnaire and were analyzed using descriptive and analytical tests with the help of SPSS version 25 software. Findings: The average age of the research subjects was 25.93±2.00, and the average duration of dysmenorrhea in each period was 2.49 days. There was no statistically significant difference in the quality of life of the students before the intervention, but after the educational intervention, a statistically significant difference was found between the two groups in terms of the quality of life and its dimensions (p<0.001). They were the same before the intervention, But after the intervention, the difference became significant (p<0.001). Conclusion: The virtual training method, like face-to-face training, can improve the quality of life and reduce the severity of primary dysmenorrhea pain in students. Therefore, depending on the conditions, both educational methods can be used.

Keywords: primary dysmenorrhea, face-to-face training, virtual, training

Procedia PDF Downloads 16
5566 Burnback Analysis of Star Grain Using Level-Set Technique

Authors: Ali Yasin, Ali Kamran, Muhammad Safdar

Abstract:

In order to reduce the hefty cost involved in terms of time and project cost, the development and application of advanced numerical tools to address the burn-back analysis problem in solid rocket motor design and development is the need of time. Several advanced numerical schemes have been developed in recent times, but their usage in the design of propellant grain of solid rocket motors is very rare. In this paper, an advanced numerical technique named the Level-Set method has been utilized for the burn-back analysis of star grain to study the effect of geometrical parameters on ballistic performance indicators such as solid loading, neutrality, and sliver percentage. In the level set technique, simple finite difference methods may fail quickly and require more sophisticated non-oscillatory schemes for feasible long-time simulation. For internal ballistic calculations, a simplified equilibrium pressure method is utilized. Preliminary results of the operative conditions, for all the combustion time, of star grain burn-back using level set techniques are compared with published results using CAD technique to test the developed numerical model.

Keywords: solid rocket motor, internal ballistic, level-set technique, star grain

Procedia PDF Downloads 107
5565 Glycosaminoglycan, a Cartilage Erosion Marker in Synovial Fluid of Osteoarthritis Patients Strongly Correlates with WOMAC Function Subscale

Authors: Priya Kulkarni, Soumya Koppikar, Narendrakumar Wagh, Dhanshri Ingle, Onkar Lande, Abhay Harsulkar

Abstract:

Cartilage is an extracellular matrix composed of aggrecan, which imparts it with a great tensile strength, stiffness and resilience. Disruption in cartilage metabolism leading to progressive degeneration is a characteristic feature of Osteoarthritis (OA). The process involves enzymatic depolymerisation of cartilage specific proteoglycan, releasing free glycosaminoglycan (GAG). This released GAG in synovial fluid (SF) of knee joint serves as a direct measure of cartilage loss, however, limited due to its invasive nature. Western Ontario and McMaster Universities Arthritis Index (WOMAC) is widely used for assessing pain, stiffness and physical-functions in OA patients. The scale is comprised of three subscales namely, pain, stiffness and physical-function, intends to measure patient’s perspective of disease severity as well as efficacy of prescribed treatment. Twenty SF samples obtained from OA patients were analysed for their GAG values in SF using DMMB based assay. LK 1.0 vernacular version was used to attain WOMAC scale. The results were evaluated using SAS University software (Edition 1.0) for statistical significance. All OA patients revealed higher GAG values compared to the control value of 78.4±30.1µg/ml (obtained from our non-OA patients). Average WOMAC calculated was 51.3 while pain, stiffness and function estimated were 9.7, 3.9 and 37.7, respectively. Interestingly, a strong statistical correlation was established between WOMAC function subscale and GAG (p = 0.0102). This subscale is based on day-to-day activities like stair-use, bending, walking, getting in/out of car, rising from bed. However, pain and stiffness subscale did not show correlation with any of the studied markers and endorsed the atypical inflammation in OA pathology. On one side, where knee pain showed poor correlation with GAG, it is often noted that radiography is insensitive to cartilage degenerative changes; thus OA remains undiagnosed for long. Moreover, active cartilage degradation phase remains elusive to both, patient and clinician. Through analysis of large number of OA patients we have established a close association of Kellgren-Lawrence grades and increased cartilage loss. A direct attempt to correlate WOMAC and radiographic progression of OA with various biomarkers has not been attempted so far. We found a good correlation in GAG levels in SF and the function subscale.

Keywords: cartilage, Glycosaminoglycan, synovial fluid, western ontario and McMaster Universities Arthritis Index

Procedia PDF Downloads 427
5564 Mechanical Properties of Die-Cast Nonflammable Mg Alloy

Authors: Myoung-Gon Yoon, Jung-Ho Moon, Tae Kwon Ha

Abstract:

Tensile specimens of nonflammable AZ91D Mg alloy were fabricated in this study via cold chamber die-casting process. Dimensions of tensile specimens were 25mm in length, 4mm in width, and 0.8 or 3.0mm in thickness. Microstructure observation was conducted before and after tensile tests at room temperature. In the die casting process, various injection distances from 150 to 260mm were employed to obtain optimum process conditions. Distribution of Al12Mg17 phase was the key factor to determine the mechanical properties of die-cast Mg alloy. Specimens with 3mm of thickness showed superior mechanical properties to those with 0.8mm of thickness. Closed networking of Al12Mg17 phase along grain boundary was found to be detrimental to mechanical properties of die-cast Mg alloy.

Keywords: non-flammable magnesium alloy, AZ91D, die-casting, microstructure, mechanical properties

Procedia PDF Downloads 291
5563 Preserved Relative Differences between Regions of Different Thermal Scans

Authors: Tahir Majeed, Michael Handschuh, René Meier

Abstract:

Rheumatoid arthritis patients have swelling and pain at the joints of the hand. The regions where the patient feels pain also show increased body temperature. Thermal cameras can be used to detect the rise in temperature of the affected regions. To monitor the disease progression of rheumatoid arthritis patients, they must visit the clinic regularly for scanning and examination. After scanning and evaluation, the dosage of the medicine is regulated accordingly. To monitor the disease progression over time, the correlation between the images between different visits must be established. It has been observed that by using low-cost thermal cameras, the thermal measurements do not remain the same over time, even within a single scanning. In some situations, temperatures can vary as much as 2°C within the same scanning sequence. In this paper, it has been shown that although the absolute temperature varies over time, the relative difference between the different regions remains similar. Results have been computed over four scanning sequences and are presented.

Keywords: relative thermal difference, rheumatoid arthritis, thermal imaging, thermal sensors

Procedia PDF Downloads 179
5562 A (Morpho) Phonological Typology of Demonstratives: A Case Study in Sound Symbolism

Authors: Seppo Kittilä, Sonja Dahlgren

Abstract:

In this paper, a (morpho)phonological typology of proximal and distal demonstratives is proposed. Only the most basic proximal (‘this’) and distal (‘that’) forms have been considered, potential more fine-grained distinctions based on proximity are not relevant to our discussion, nor are the other functions the discussed demonstratives may have. The sample comprises 82 languages that represent the linguistic diversity of the world’s languages, although the study is not based on a systematic sample. Four different major types are distinguished; (1) Vowel type: front vs. back; high vs. low vowel (2) Consonant type: front-back consonants (3) Additional element –type (4) Varia. The proposed types can further be subdivided according to whether the attested difference concern only, e.g., vowels, or whether there are also other changes. For example, the first type comprises both languages such as Betta Kurumba, where only the vowel changes (i ‘this’, a ‘that’) and languages like Alyawarra (nhinha vs. nhaka), where there are also other changes. In the second type, demonstratives are distinguished based on whether the consonants are front or back; typically front consonants (e.g., labial and dental) appear on proximal demonstratives and back consonants on distal demonstratives (such as velar or uvular consonants). An example is provided by Bunaq, where bari marks ‘this’ and baqi ‘that’. In the third type, distal demonstratives typically have an additional element, making it longer in form than the proximal one (e.g., Òko òne ‘this’, ònébé ‘that’), but the type also comprises languages where the distal demonstrative is simply phonologically longer (e.g., Ngalakan nu-gaʔye vs. nu-gunʔbiri). Finally, the last type comprises cases that do not fit into the three other types, but a number of strategies are used by the languages of this group. The two first types can be explained by iconicity; front or high phonemes appear on the proximal demonstratives, while back/low phonemes are related to distal demonstratives. This means that proximal demonstratives are pronounced at the front and/or high part of the oral cavity, while distal demonstratives are pronounced lower and more back, which reflects the proximal/distal nature of their referents in the physical world. The first type is clearly the most common in our data (40/82 languages), which suggests a clear association with iconicity. Our findings support earlier findings that proximal and distal demonstratives have an iconic phonemic manifestation. For example, it has been argued that /i/ is related to smallness (small distance). Consonants, however, have not been considered before, or no systematic correspondences have been discovered. The third type, in turn, can be explained by markedness; the distal element is more marked than the proximal demonstrative. Moreover, iconicity is relevant also here: some languages clearly use less linguistic substance for referring to entities close to the speaker, which is manifested in the longer (morpho)phonological form of the distal demonstratives. The fourth type contains different kinds of cases, and systematic generalizations are hard to make.

Keywords: demonstratives, iconicity, language typology, phonology

Procedia PDF Downloads 135
5561 An Extremely Rare Anatomical Vascular Variant of Lower Limb Arterial System - Duplication of Superficial Femoral Artery

Authors: Manik Sharma

Abstract:

Understanding the anatomy and normal anatomical variations of the lower limb arterial system is undeniably important not only to understand the pathology involving the vessels of the lower limb but also as a part of endovascular intervention and surgical planning in cases that demand them as a part of treatment. There have been very few cases of duplication of SFA cited in the literature, close to six worldwide and this being the seventh case in the world and first to be reported in the Indian population. We incidentally came across this normal variant during US lower limb (US-LL) duplex scan in a patient with claudicating pain in bilateral lower limbs hence suspected of having peripheral vascular disease. It was confirmed on CT-Peripheral Angiography (CT-PA), which was done successively.

Keywords: peripheral vascular disease, claudicating pain, normal anatomical variants, endovascular intervention, duplication, CT-peripheral angiography, duplex scan, Iohexol

Procedia PDF Downloads 150
5560 A Study on Improvement of the Electromagnetic Vibration of a Polygon Mirror Scanner Motor

Authors: Yongmin You

Abstract:

Electric machines for office automation device such as printer and scanner have been required the low noise and vibration performance. Many researches about the low noise and vibration of polygon mirror scanner motor have been also progressed. The noise and vibration of polygon mirror scanner motor can be classified by aerodynamic, structural and electromagnetic. Electromagnetic noise and vibration can be occurred by high cogging torque and nonsinusoidal back EMF. To improve the cogging torque and back EMF characteristic, we apply unequal air-gap. To analyze characteristic of a polygon mirror scanner motor, two dimensional finite element method is used. To minimize the cogging torque of a polygon mirror motor, Kriging based on latin hypercube sampling (LHS) is utilized. Compared to the initial model, the torque ripple of the optimized unequal air-gap model was reduced by 23.4 % while maintaining the back EMF and average torque. To verify the optimal design results, the experiment was performed. We measured the vibration in motors at 23,600 rpm which is the rated velocity. The radial and axial gravitational acceleration of the optimal model were declined more than seven times and three times, respectively. From these results, a shape optimized unequal polygon mirror scanner motor has shown the usefulness of an improvement in the torque ripple and electromagnetic vibration characteristic.

Keywords: polygon mirror scanner motor, optimal design, finite element method, vibration

Procedia PDF Downloads 326
5559 Effect of Muscle Energy Technique on Anterior Pelvic Tilt in Lumbar Spondylosis Patients

Authors: Enas El Sayed Abutaleb, Mohamed Taher Eldesoky, Shahenda Abd El Rasol

Abstract:

Background: Muscle energy techniques (MET) have been widely used by manual therapists over the past years, but still limited research validated its use and there was limited evidence to substantiate the theories used to explain its effects. Objective: To investigate the effect of muscle energy technique (MET) on anterior pelvic tilt in patients with lumbar spondylosis. Design: Randomized controlled trial. Subjects: Thirty patients with anterior pelvic tilt from both sexes were involved, aged between 35 to 50 years old and they were divided into MET and control groups with 15 patients in each. Methods: All patients received 3 sessions/week for 4 weeks where the study group received MET, Ultrasound and Infrared, and the control group received U.S and I.R only. Pelvic angle was measured by palpation meter, pain severity by the visual analogue scale and functional disabilities by the Oswestry disability index. Results: Both groups showed significant improvement in all measured variables. The MET group was significantly better than the control group in pelvic angle, pain severity, and functional disability as p-value were (0.001, 0.0001, 0.0001) respectively. Conclusion and implication: The study group fulfilled greater improvement in all measured variables than the control group which implies that application of MET in combination with U.S and I.R were more effective in improving pelvic tilting angle, pain severity and functional disabilities than using electrotherapy only.

Keywords: anterior pelvic tilt, lumbar spondylosis, muscle energy technique exercise, pelvic tilting angle

Procedia PDF Downloads 371
5558 Late Pleistocene Raised Coral Reefs in Rabigh Area, Red Sea: Microfacies and Environmental Interpretation

Authors: Ammar Manaa

Abstract:

The late Pleistocene raised coral reef terraces, 1 to 5 m above present sea level, are distinguished in Rabigh area into two marine terraces at elevations 0.5 m and 3.20 m, in addition to back-reef facies. The lower and upper terraces consist mainly of corals that increased in abundance and distribution in the upper terrace, with a minor occurrence of detrital quartz and feldspar. The back-reef facies consist mainly of coralline algae with a minor occurrence of corals. The upper terrace was interpreted as a reef crest or algal ridge due to the dominance of bindstone facies. The lower terrace indicates an outer reef flat with the occurrence of grainstone and rudstone facies. The coral framework in the upper terrace indicates a low energy environment. Within the back-reef terrace, calcareous mud was dominant, which indicates low energy, lagoon environment. The XRD results for the studied terraces revealed a variable abundance of aragonite, high-Mg calcite, and low-Mg calcite, with a slight increase in calcite and high-Mg calcite in the upper terrace. The dominant diagenetic processes in the terraces are cementation by fibrous and blocky calcite and dissolution that varied slightly between the lower and upper terraces. This study provides a coral reef model relevant to a low energy system in a dry and hot environment.

Keywords: late Pleistocene, Rabigh, reef terraces, Red Sea, Saudi Arabia.

Procedia PDF Downloads 115
5557 Multivariate Analysis on Water Quality Attributes Using Master-Slave Neural Network Model

Authors: A. Clementking, C. Jothi Venkateswaran

Abstract:

Mathematical and computational functionalities such as descriptive mining, optimization, and predictions are espoused to resolve natural resource planning. The water quality prediction and its attributes influence determinations are adopted optimization techniques. The water properties are tainted while merging water resource one with another. This work aimed to predict influencing water resource distribution connectivity in accordance to water quality and sediment using an innovative proposed master-slave neural network back-propagation model. The experiment results are arrived through collecting water quality attributes, computation of water quality index, design and development of neural network model to determine water quality and sediment, master–slave back propagation neural network back-propagation model to determine variations on water quality and sediment attributes between the water resources and the recommendation for connectivity. The homogeneous and parallel biochemical reactions are influences water quality and sediment while distributing water from one location to another. Therefore, an innovative master-slave neural network model [M (9:9:2)::S(9:9:2)] designed and developed to predict the attribute variations. The result of training dataset given as an input to master model and its maximum weights are assigned as an input to the slave model to predict the water quality. The developed master-slave model is predicted physicochemical attributes weight variations for 85 % to 90% of water quality as a target values.The sediment level variations also predicated from 0.01 to 0.05% of each water quality percentage. The model produced the significant variations on physiochemical attribute weights. According to the predicated experimental weight variation on training data set, effective recommendations are made to connect different resources.

Keywords: master-slave back propagation neural network model(MSBPNNM), water quality analysis, multivariate analysis, environmental mining

Procedia PDF Downloads 456
5556 A New Mechanical Architecture Design of a Multifunctional Bed for Bedridden Healthcare

Authors: Rogelio Portillo Vélez, Eduardo Vázquez-Santacruz, Mariano Gamboa-Zúñiga

Abstract:

In this paper a new mechanical architecture design of a multi functional robot bed, is presented. The importance of this design relies on the fact that in next years the need of assistive devices development will increase in such way that elderly patients will use this kind of devices. This mechanical design implies following specific mechanisms which attend Mexican hospital requirements. This design is the base of next step of this kind of development given that it shows all technical details of the mechanical systems which are needed in order to construct the bed. This is first hospital bed design which could responds to the Latin America hospital requirements. We have obtained these hospital requirements using our diagnosis methodology [14]. From these results we have designed the mechanical system. This is the mechanical base of the hospital robotic bed which is being developed in our robotics laboratory. It will be useful in different hospital environments for elderly and disabled patients.

Keywords: assistive robotics, methodology, feasibility analysis, robotics, operational feasibility, assistive technology, viability analysis matrix, social impact

Procedia PDF Downloads 378
5555 Long-Term Mechanical and Structural Properties of Metakaolin-Based Geopolymers

Authors: Lenka Matulova

Abstract:

Geopolymers are alumosilicate materials that have long been studied. Despite this fact, little is known about the long-term stability of geopolymer mechanical and structural properties, so crucial for their successful industrial application. To improve understanding, we investigated the effect of four different types of environments on the mechanical and structural properties of a metakaolin-based geopolymer (MK GP). The MK GP samples were stored in laboratory conditions (control samples), in water at 20 °C, in water at 80 °C, and outside exposed to the weather. Compressive and tensile strengths were measured after 28, 56, 90, and 360 days. In parallel, structural properties were analyzed using XRD, SEM, and mercury intrusion porosimetry. Whereas the mechanical properties of the samples in laboratory conditions and in 20 °C water were stable, the mechanical properties of the outdoor samples and the samples 80 °C water decreased noticeably after 360 days. Structural analyses were focused on changes in sample microstructure (developing microcrack network, porosity) and identifying zeolites, the presence of which would indicate detrimental processes in the structure that can change it from amorphous to crystalline. No zeolites were found during the 360-day period in MK GP samples, but the reduction in mechanical properties coincided with a developing network of microcracks and changes in pore size distribution.

Keywords: geopolymer, long-term properties, mechanical properties, metakaolin, structural properties

Procedia PDF Downloads 217
5554 Effect of Low Level Laser Therapy versus Ultrasound on Musculoskeletal Conditions

Authors: Andrew Anis Fakhrey Mosaad

Abstract:

This Musculoskeletal (MSK) conditions are a major contributing factor in disability. This becomes more challenging as the world population is witnessing an increase in the geriatric population. Various treatment strategies are being researched to provide the most effective and non-invasive approach. To date, low-level laser therapy (LLLT) is one of the emerging modalities to treat different musculoskeletal conditions in physical therapy practice. Physical therapy practice uses different modalities to control pain and inflammation. LLLT has been under research for the last two decades and has shown varying results. This literature review focuses on the effectiveness of LLLT in different musculoskeletal conditions. Using search engines of PubMed and Google Scholar, a number of articles have been reviewed based on the inclusion and exclusion criteria. LLLT shows promising results in treating different musculoskeletal conditions. However, clinicians need to ensure to follow the recommended dosage parameters for specific musculoskeletal conditions.

Keywords: musculoskeletal conditions, low level laser therapy, ultrasound, wavelength, pain and inflammation

Procedia PDF Downloads 86
5553 Individual Actuators of a Car-Like Robot with Back Trailer

Authors: Tarek El-Derini, Ahmed El-Shenawy

Abstract:

This paper presents the hardware implemented and validation for a special system to assist the unprofessional users of car with back trailers. The system consists of two platforms; the front car platform (C) and the trailer platform (T). The main objective is to control the Trailer platform using the actuators found in the front platform (c). The mobility of the platform (C) is investigated and inverse and forward kinematics model is obtained for both platforms (C) and (T). The system is simulated using Matlab M-file and the simulation examples results illustrated the system performance. The system is constructed with a hardware setup for the front and trailer platform. The hardware experimental results and the simulated examples outputs showed the validation of the hardware setup.

Keywords: kinematics, modeling, robot, MATLAB

Procedia PDF Downloads 424
5552 An Unusual Case of Wrist Pain: Idiopathic Avascular Necrosis of the Scaphoid, Preiser’s Disease

Authors: Adae Amoako, Daniel Montero, Peter Murray, George Pujalte

Abstract:

We present a case of a 42-year-old, right-handed Caucasian male who presented to a medical orthopedics clinic with left wrist pain. The patient indicated that the pain started two months prior to the visit. He could only remember helping a friend move furniture prior to the onset of pain. Examination of the left wrist showed limited extension compared to the right. There was clicking with flexion and extension of the wrist on the dorsal aspect. Mild tenderness was noticed over the distal radioulnar joint. There was ulnar and radial deviation on provocation. Initial 4-view x-rays of the left wrist showed mild radiocarpal and scapho-trapezium-trapezoid (ST-T) osteoarthritis, with subchondral cysts seen in the lunate and scaphoid, with no obvious fractures. The patient was initially put in a wrist brace and diclofenac topical gel was prescribed for pain control, as a patient could not take non-steroidal anti-inflammatory drugs (NSAIDs) due to gastritis. Despite diclofenac topical gel use and bracing, symptoms remained, and a steroid injection with 1 mL of lidocaine with 10 mg of triamcinolone acetonide was performed under fluoroscopy. He obtained some relief but after 3 months, the injection had to be repeated. On 2-month follow up after the initial evaluation, symptoms persisted. Magnetic resonance imaging (MRI) was obtained which showed an abnormal T1 hypodense signal involving the proximal pole of the scaphoid and articular collapse proximally of the scaphoid, with marked irregularity of the overlying cartilage, suggesting a remote injury, findings consistent with avascular necrosis of the proximal pole of the scaphoid. A month after that, the patient had the left proximal pole of the scaphoid debrided and an intercompartmental supraretinacular artery vascularized. Pedicle bone graft reconstruction of the proximal pole of the left scaphoid was done. A non-vascularized autograft from the left radius was also applied. He was put in a thumb spica cast with the interphalangeal joint free for 6 weeks. On 6-week follow-up after surgery, the patient was healing well and could make a composite fist with his left hand. The diagnosis of Preiser’s disease is primarily based on radiological findings. Due to the fact that necrosis happens over a period of time, most AVNs are diagnosed at the late stages of the disease. There appear to be no specific guidelines on the management AVN of the scaphoid. In the past, immobilization and arthroscopic debridement had been used. Radial osteotomy has also been tried. Vascularized bone grafts have also been used to treat Preiser’s disease. In our patient, we used three of these treatment modalities, starting with conservative management with topical NSAIDS and immobilization, then debridement with vascularized bone grafts.

Keywords: wrist pain, avascular necrosis of the scaphoid, Preiser’s disease, vascularized bone grafts

Procedia PDF Downloads 279
5551 The Application of Artificial Neural Network for Bridge Structures Design Optimization

Authors: Angga S. Fajar, A. Aminullah, J. Kiyono, R. A. Safitri

Abstract:

This paper discusses about the application of ANN for optimizing of bridge structure design. ANN has been applied in various field of science concerning prediction and optimization. The structural optimization has several benefit including accelerate structural design process, saving the structural material, and minimize self-weight and mass of structure. In this paper, there are three types of bridge structure that being optimized including PSC I-girder superstructure, composite steel-concrete girder superstructure, and RC bridge pier. The different optimization strategy on each bridge structure implement back propagation method of ANN is conducted in this research. The optimal weight and easier design process of bridge structure with satisfied error are achieved.

Keywords: bridge structures, ANN, optimization, back propagation

Procedia PDF Downloads 356
5550 Improving Power Quality in Wind Power Generation System

Authors: A. Omeiri, A. Djellad, P. O. Logerais, O. Riou, J. F. Durastanti

Abstract:

With the growing of electrical energy demand, wind power capacity has experienced tremendous growth in the past decade, thanks to wind power’s environmental benefits. Direct driven permanent magnet synchronous generator (PMSG) with a full size back-to-back converter set is one of the promising technologies employed with wind power generation. Wind grid integration brings the problems of voltage fluctuation and harmonic pollution. In the present study, the filter is placed between the wind system and the network to reduce the total harmonic distortion (THD) and enhance power quality during disturbances. The models of wind turbine, PMSG, power electronic converters and the filter are implemented in MATLAB/SIMULINK environment.

Keywords: wind energy conversion system, PMSG, PWM, THD, power quality, passive filter

Procedia PDF Downloads 627
5549 The Influence of Plyometric Exercises on Biomechanical Factor Front Crawl and Back Crawl Speed in Elite Swimmers

Authors: Gheimati Salar

Abstract:

The objective of conducting this research was to study the influence of plyometric exercises on the biomechanical selected factor of elite teen swimmers and compare the influence of plyometric exercises on the speed of front crawl and back crawl in empirical and control groups of teens. In order to conduct these study 30 swimmers with minimum of 3 years' experience who were 11 or 12 were randomly chosen and divided into 2 groups of 15. The first group was empirical and the second was control group. The speed of the swimmer was analyzed after 25 meters of swimming and their speed were recorded in the last. The researcher was standing stable at the beginning and then started the chronometer and stopped it at the end of the swimming. He repeated the record taking two times and then the average was taken. Before conducting plyometric exercises, a speed test was taken from both groups in both types of swimming. The duration of plyometric exercises was 8 weeks, every week 3 sessions and 24 sessions in total. The exercises in this study were focused on 3 parts of the body. Upper limb part, the lower part of the body and trunk area. Upper limb exercises consisted of four parts. The lower limb exercises consisted of 5 parts, and the trunk exercises consisted of four sections. A Medicine ball, cone and different weights were used in these exercises.

Keywords: plyometric, exercises, front crawl and back crawl, speed

Procedia PDF Downloads 96
5548 Production and Quality Control of a Novel 153Sm-Complex for Radiotherapy of Bone-Metastases

Authors: H. Yousefnia, R. Enayati, M. Hosntalab, S. Zolghadri, A. Bahrami-Samani

Abstract:

Bone metastases occur in many cases at an early stage of the tumour disease, however their symptoms are recognized rather late. The aim of this study was the preparation of 153Sm-(4-{[bis-(phosphonomethyl))carbamoyl]methyl}-7,10-bis(carboxymethyl) 1,4,7,10-tetraazacyclododec-1-yl) acetic acid (BPAMD) for bone pain palliation therapy. 153Sm was produced at Tehran research reactor via 152Sm(n,γ)153Sm reaction. 200 µl of 1mg/ml BPAMD solution was added to the vial containing 1 mCi 153Sm and the mixture was heated up to 90 0C for 1 h. The radiochemical purity of the complex was measured by ITLC method. The final solution with radiochemical purity of more than 95% was injected to BALB mice and bio distribution was determined up to 48 h. SPECT images were acquired after 2 and 24 h post injection. While high bone uptake was confirmed by both the bio distribution studies and SPECT imaging, accumulation in other organs was approximately negligible. The results show that 153Sm-BPAMD can be used as an excellent tracer for bone pain palliation therapy.

Keywords: bone metastases, BPAMD, 153Sm, radiotherapy

Procedia PDF Downloads 583
5547 A Comparison of Kinetic and Mechanical Properties between Graphene Oxide (GO) and Carbon Nanotubes (CNT)-Epoxy Nanocomposites

Authors: Marina Borgert Moraes, Gilmar Patrocinio Thim

Abstract:

It is still unknown how the presence of nanoparticles such as graphene oxide (GO) or carbon nanotubes (CNT) influence the curing process and the final mechanical properties as well. In this work, kinetic and mechanical properties of the nanocomposites were analyzed, where the kinetic process was followed by DSC and the mechanical properties by DMA as well as mechanical tests. Initially, CNT was annealed at high temperature (1800 °C) under vacuum atmosphere, followed by a chemical treatment using acids and ethylenediamine. GO was synthesized through chemical route, washed clean, dried and ground to #200. The presence of functional groups on CNT and GO surface was confirmed by XPS spectra and FT-IR. Then, nanoparticles and acetone were mixed by sonication in order to obtain the composites. DSC analyses were performed on samples with different curing cycles (1h 80 °C + 2h 120 °C; 3h 80 °C + 2h 120 °C; 5h 80 °C) and samples with different times at constant temperature (120 °C). Mechanical tests were performed according to ASTM D638 and D790. Results showed that the kinetic process and the mechanical strength are very dependent on the presence of graphene and functionalized-CNT in the nanocomposites, and the GO reinforced samples had a slightly bigger improvement compared to functionalized CNT.

Keywords: carbon nanotube, epoxy resin, graphene oxide, nanocomposite

Procedia PDF Downloads 247
5546 Systems Contextual Integrated Model for Clinical Psychology and Social Work

Authors: Raymond C. Hawkins II, Catherine A. Hawkins

Abstract:

The System Contextual Integrated Model (SCIM), developed as a trans-theoretical framework for selecting measures for psychotherapy process and outcome, is reformulated for behavioral health applications. The SCIM “healing cycle” is an allostatic hedonic affective-cognitive right-hemisphere–left-hemisphere coordinated process involving positive alliesthesia that mitigates traumatic pain and generates psychological flexibility. The SCIM “trauma cycle” is an allostatic overload alliesthesia opponent process with long-lasting pathology sequelae. The social ecological context moderates the “healing cycle” and the “trauma cycle.” Repeated evocation of the “healing cycle” in a therapeutic relationship can gradually relieve trauma sequelae. The SCIM is applied to pain, obese binge eating, and substance use disorders.

Keywords: allostasis, alliesthesia, opponent process, behavioral health, assessment

Procedia PDF Downloads 127
5545 Effectiveness Evaluation of a Machine Design Process Based on the Computation of the Specific Output

Authors: Barenten Suciu

Abstract:

In this paper, effectiveness of a machine design process is evaluated on the basis of the specific output calculus. Concretely, a screw-worm gear mechanical transmission is designed by using the classical and the 3D-CAD methods. Strength analysis and drawing of the designed parts is substantially aided by employing the SolidWorks software. Quality of the design process is assessed by manufacturing (printing) the parts, and by computing the efficiency, specific load, as well as the specific output (work) of the mechanical transmission. Influence of the stroke, travelling velocity and load on the mechanical output, is emphasized. Optimal design of the mechanical transmission becomes possible by the appropriate usage of the acquired results.

Keywords: mechanical transmission, design, screw, worm-gear, efficiency, specific output, 3D-printing

Procedia PDF Downloads 125
5544 The Effect of Proprioceptive Neuromuscular Facilitation and Lumbar Stabilization Exercises on Muscle Strength and Muscle Endurance in Patients with Lumbar Disc Hernia

Authors: Mustafa Gulsen, Mitat Koz

Abstract:

The aim of this study is to investigate the effect of lumbar stabilisation and proprioceptive neuromuscular facilitation (PNF) training on muscle strength and muscle endurance. The participants were 64 between the ages of 15-69 (53.04 ± 14.59), who were graded protrusion and bulging lumbar herniation according to 'Macnab Classification'. The participants were divided into four groups as each group had 16 participants: lumbar stabilitation training, PNF training, physical therapy and control groups. Sociodemographic features were recorded. Then their muscle strength tests (by isokinetic dynamometer (Cybex 770 Norm Lumex Inc, Ronkonkoma, NY, USA) were recorded. Before and after applications; visual analogue scale (VAS), Oswestry Disability İndex were applied by a physical therapist. The participants in lumbar stabilisation group performed 45 minutes, 5 days in a week for 4 weeks strength training with a physical therapist observation. The participants in PNF group performed 5 days in a week for 4 weeks with pelvic patterns of PNF by a physiotherapist. The participants in physical therapy group underwent Hotpack, Tens and Ultrasound therapy 5 days in a week for 4 weeks. The participants in control group didn’t take any training programme. After 4 weeks, the evaluations were repeated. There were significant increases in muscle strength and muscle endurance in lumbar stabilization training group. Also in pain intensity at rest and during activity in this group and in Oswestry disability index of patients, there were significant improvements (p < 0.05). In PNF training group likewise, there were significant improvements in muscle strength, muscle endurance, pain intensity at rest and with activity and in Oswestry disability index (p < 0.05). But improvements in the Lumbar Stabilization group was better than PNF Group. We found significant differences only in pain intensity at rest and with activity and in Oswestry disability index (p < 0.05). in the patients in Physical Therapy group. We think that appropriate physiotherapy and rehabilitation program which will be prepared for patients, to protect the waist circumference of patients with low muscle strength and low muscle endurance will increase muscle strength and muscle endurance. And it is expected that will reduce pain and will provide advances toward correcting functional disability of the patients.

Keywords: disc herniation, endurance, lumbar stabilitation exercises, PNF, strength

Procedia PDF Downloads 266
5543 Degradation of the Mechanical Properties of the Polypropylene Talc Nanocomposite in Chemical Environment

Authors: Ahmed Ouadah Bouakkaz, Mohamed Elmeguenni, Bel Abbes Bachir Bouiadjra, Mohamed Belhouari, Abdulmohsen Albedah

Abstract:

In this study, the effect of the chemical environment on the mechanical properties of the polypropylene-talc composite was analyzed. The talc proportion was varied in order to highlight the combined effects of time of immersion in the chemical environment 'benzene' and talc concentration on the mechanical properties of the composite. Tensile test was carried out to evaluate the mechanical properties of PP-talc composite and to analyze the effect of the immersion time on the variation of these properties. The obtained results show that increasing the time of immersion has a very negative effect on the mechanical strength of the PP-talc composite, but this effect can be significantly reduced by the augmentation of the talc proportion.

Keywords: polypropylene (PP), talc, nanocomposite, degradation

Procedia PDF Downloads 363
5542 Combined Effect of Therapeutic Exercises and Shock Wave versus Therapeutic Exercises and Phonophoresis in Treatment of Shoulder Impingement Syndrome: A Randomized Controlled Trial

Authors: Mohamed M. Mashaly, Ahmed M. F. El Shiwi

Abstract:

Background: Shoulder impingement syndrome is an encroachment of subacromial tissues, rotator cuff, subacromial bursa, and the long head of the biceps tendon, as a result of narrowing of the subacromial space. Activities requiring repetitive or sustained use of the arms over head often predispose the rotator cuff tendon to injury. Purpose: To compare between Combined effect therapeutic exercises and Shockwave therapy versus therapeutic exercises and phonophoresis in the treatment of shoulder impingement syndrome. Methods: Thirty patients diagnosed as shoulder impingement syndrome stage II Neer classification due to mechanical causes. Patients were randomly distributed into two equal groups. The first group consisted of 15 patients with a mean age of (45.46+8.64) received therapeutic exercises (stretching exercise of posterior shoulder capsule and strengthening exercises of shoulder muscles) and shockwave therapy (6000 shocks, 2000/session, 3 sessions, 2 weeks apart, 0.22mJ/mm^2) years. The second group consisted of 15 patients with a mean age of 46.26 (+ 8.05) received same therapeutic exercises and phonophoresis (3 times per week, each other day, for 4 consecutive weeks). Patients were evaluated pretreatment and post treatment for shoulder pain severity, shoulder functional disability, shoulder flexion, abduction and internal rotation motions. Results: Patients of both groups showed significant improvement in all the measured variables. In between groups difference the shock wave group showed a significant improvement in all measured variables than phonophoresis group. Interpretation/Conclusion: Combined effect of therapeutic exercises and shock wave were more effective than therapeutic exercises and phonophoresis on decreasing shoulder pain severity, shoulder functional disability, increasing in shoulder flexion, abduction, internal rotation in patients with shoulder impingement syndrome.

Keywords: shoulder impingement syndrome, therapeutic exercises, shockwave, phonophoresis

Procedia PDF Downloads 458
5541 Evaluation of the Mechanical Properties of Nano TiO2 and Clay Filler Filled Epoxy Composites

Authors: A. Mimaroglu, H. Unal

Abstract:

In this study, the mechanical properties of nano filled epoxy composites were evaluated. The matrix material is epoxy. nano fillers are Al2O3, TiO2 and clay added in 2.5- 10 wt% by weight ratio. Test samples were prepared using an open mould type die. Mechanical tests were carried out. The tensile strength, elastic modulus, elongation at break and the hardness of the composite materials were obtained and evaluated. It was seen from the results that the filler content had a high influence on the level of the mechanical properties of the epoxy composites.

Keywords: nano, epoxy, composite, fillers, clay

Procedia PDF Downloads 373