Search results for: Biomechanical evaluations
164 Development of a Biomechanical Method for Ergonomic Evaluation: Comparison with Observational Methods
Authors: M. Zare, S. Biau, M. Croq, Y. Roquelaure
Abstract:
A wide variety of observational methods have been developed to evaluate the ergonomic workloads in manufacturing. However, the precision and accuracy of these methods remain a subject of debate. The aims of this study were to develop biomechanical methods to evaluate ergonomic workloads and to compare them with observational methods.
Two observational methods, i.e. SCANIA Ergonomic Standard (SES) and Rapid Upper Limb Assessment (RULA), were used to assess ergonomic workloads at two simulated workstations. They included four tasks such as tightening & loosening, attachment of tubes and strapping as well as other actions. Sensors were also used to measure biomechanical data (Inclinometers, Accelerometers, and Goniometers).
Our findings showed that in assessment of some risk factors both RULA & SES were in agreement with the results of biomechanical methods. However, there was disagreement on neck and wrist postures. In conclusion, the biomechanical approach was more precise than observational methods, but some risk factors evaluated with observational methods were not measurable with the biomechanical techniques developed.
Keywords: Ergonomic, Observational Method, Biomechanical method, Workload.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 5098163 Biomechanical Properties of Hen's Eggshell: Experimental Study and Numerical Modeling
Authors: A. Darvizeh, H. Rajabi, S. Fatahtooei Nejad, A. Khaheshi, P. Haghdoust
Abstract:
In this article, biomechanical aspects of hen-s eggshell as a natural ceramic structure are studied. The images, taken by a scanning electron microscope (SEM), are used to investigate the microscopic aspects of the egg. It is observed that eggshell has a three-layered microstructure with different morphological and structural characteristics. Studies on the eggshell membrane (ESM) as a prosperous tissue suggest that it is placed to prevent the penetration of microorganisms into the egg. Finally, numerical models of the egg are presented to study the stress distribution and its deformation under different loading conditions. The effects of two different types of loading (hydrostatic and point loadings) on two different shell models (with constant and variable thicknesses) are investigated in detail.
Keywords: Eggshell, biomechanical properties, Scanning electron microscope, Numerical Modeling.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2468162 Modeling of Titanium Alloy Implant for Fractured Distal Femur
Authors: Abhishek Soni, Bhagat Singh
Abstract:
In the present work, reverse engineering (RE) approach has been used to create a 3D model of a fractured femur bone using the computed tomography (CT) scan data. Thereafter, counter fit fixation plates of Titanium alloy (Ti6Al4V) have been designed and analyzed considering physiological static loading conditions. From the analysis, it has been inferred that the stresses and deformation developed are quite low. It implies that these designed customized fixation plates are able to provide stable fixation resulting in improved fracture union.Keywords: Biomechanical evaluations, customized implant, reverse engineering, titanium alloy.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 721161 The Effect of Electrical Stimulation Intensity on VEGF Expression and Biomechanical Properties during Wound
Authors: M R Asadi, G Torkaman, M Hedayati
Abstract:
We evaluated the effect of sensory (direct current (DC), 600μA) and motor (monophasic current, pulse duration 300μs, 100 Hz, 2.5-3mA) intensities of cathodal electrical stimulation (ES) current to release VEGF and biomechanical properties of wound. 54 male Sprague-dawley rats were randomly assigned into one control and two experimental groups. A full thickness skin incision was made on animals- dorsal region. The experimental groups received ES for 1h/day and every other day. VEGF expression was measured in skin on the 7th day after surgical incision and tensile strength was measured on 21st day. On the 7th day, the values of skin VEGF in the sensory group were significantly greater than those of the other groups (p < 0.05). Sensory and Motor intensity stimulation, can not improve the biomechanical properties of the repaired wounds. It seems the mechanical environment induced by sensory and motor intensity of electrical stimulation, could not simulate the role of normal daily stress and strain to maturation of collagen fibers and their cross links. Further work is needed to determine the relationship between VEGF expression after ES and its effect on tensile strength of healed wound.Keywords: Biomechanical properties Direct current, Monophasic current, Skin, VEGF
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1603160 Modeling of Cobalt-Chromium-Molybdenum Alloy Implant for Fractured Distal Femur
Authors: Abhishek Soni, Bhagat Singh
Abstract:
Distal femur fractures are the cause of abnormal gloomy. Several types of surgical treatments have been adopted by the practitioners to restore the fractured region of distal femur. Still within this domain of study, unstable fixation remains a challenge for orthopedists. In the present study, a fixation implant is designed and analyzed under physiological loading conditions for cobalt-chromium-molybdenum alloy (Co-Cr-Mo). It has been found that the stresses and deformation developed are quite low. It means that customized fixation plates will provide stable fixation resulting in improved fracture union.
Keywords: Biomechanical evaluations, customized implant, Co-Cr-Mo alloy, reverse engineering.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 766159 Optometric-lab: a Stereophotogrammetry Tool for Eye Movements Records
Authors: E. F. P. Leme, L. J. R. Lopez, D. G. Goroso
Abstract:
In this paper as showed a non-invasive 3D eye tracker for optometry clinical applications. Measurements of biomechanical variables in clinical practice have many font of errors associated with traditional procedments such cover test (CT), near point of accommodation (NPC), eye ductions (ED), eye vergences (EG) and, eye versions (ES). Ocular motility should always be tested but all evaluations have a subjective interpretations by practitioners, the results is based in clinical experiences, repeatability and accuracy don-t exist. Optometric-lab is a tool with 3 (tree) analogical video cameras triggered and synchronized in one acquisition board AD. The variables globe rotation angle and velocity can be quantified. Data record frequency was performed with 27Hz, camera calibration was performed in a know volume and image radial distortion adjustments.Keywords: Eye Tracking, strabismus, eye movements, optometry.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1830158 An Inflatable and Foldable Knee Exosuit Based on Intelligent Management of Biomechanical Energy
Authors: Jing Fang, Yao Cui, Mingming Wang, Shengli She, Jianping Yuan
Abstract:
Wearable robotics is a potential solution in aiding gait rehabilitation of lower limbs dyskinesia patients, such as knee osteoarthritis or stroke afflicted patients. Many wearable robots have been developed in the form of rigid exoskeletons, but their bulk devices, high cost and control complexity hinder their popularity in the field of gait rehabilitation. Thus, the development of a portable, compliant and low-cost wearable robot for gait rehabilitation is necessary. Inspired by Chinese traditional folding fans and balloon inflators, the authors present an inflatable, foldable and variable stiffness knee exosuit (IFVSKE) in this paper. The pneumatic actuator of IFVSKE was fabricated in the shape of folding fans by using thermoplastic polyurethane (TPU) fabric materials. The geometric and mechanical properties of IFVSKE were characterized with experimental methods. To assist the knee joint smartly, an intelligent control profile for IFVSKE was proposed based on the concept of full-cycle energy management of the biomechanical energy during human movement. The biomechanical energy of knee joints in a walking gait cycle of patients could be collected and released to assist the joint motion just by adjusting the inner pressure of IFVSKE. Finally, a healthy subject was involved to walk with and without the IFVSKE to evaluate the assisting effects.
Keywords: Biomechanical energy management, gait rehabilitation, knee exosuit, wearable robotics.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1167157 Design of Stainless Steel Implant for Fractured Distal Femur
Authors: Abhishek Soni, Bhagat Singh
Abstract:
Perfect restoration of fractured distal femur has been a challenging task for the medical practitioners. In the present study, model of a fractured bone has been created using the scan data of the damaged bone. Thereafter, customized implant of Stainless Steel (SS-316L) for this fractured femur bone is modeled using the reverse engineering approach. Clinical set-up is prepared by assembling all the models together. Stress and deformation analysis of this clinical set-up has been performed in order to check the load bearing capacity and intactness of the joint. From this analysis, it has been inferred that the stresses and deformation developed due to the static load of the person is within the permissible limits.
Keywords: Biomechanical evaluations, customized implant, reverse engineering, stainless steel alloy.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 811156 Material Density Mapping on Deformable 3D Models of Human Organs
Authors: Petru Manescu, Joseph Azencot, Michael Beuve, Hamid Ladjal, Jacques Saade, Jean-Michel Morreau, Philippe Giraud, Behzad Shariat
Abstract:
Organ motion, especially respiratory motion, is a technical challenge to radiation therapy planning and dosimetry. This motion induces displacements and deformation of the organ tissues within the irradiated region which need to be taken into account when simulating dose distribution during treatment. Finite element modeling (FEM) can provide a great insight into the mechanical behavior of the organs, since they are based on the biomechanical material properties, complex geometry of organs, and anatomical boundary conditions. In this paper we present an original approach that offers the possibility to combine image-based biomechanical models with particle transport simulations. We propose a new method to map material density information issued from CT images to deformable tetrahedral meshes. Based on the principle of mass conservation our method can correlate density variation of organ tissues with geometrical deformations during the different phases of the respiratory cycle. The first results are particularly encouraging, as local error quantification of density mapping on organ geometry and density variation with organ motion are performed to evaluate and validate our approach.
Keywords: Biomechanical simulation, dose distribution, image guided radiation therapy, organ motion, tetrahedral mesh, 4D-CT.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3010155 Usability in E-Commerce Websites: Results of Eye Tracking Evaluations
Authors: Beste Kaysı, Yasemin Topaloğlu
Abstract:
Usability is one of the most important quality attributes for web-based information systems. Specifically, for e-commerce applications, usability becomes more prominent. In this study, we aimed to explore the features that experienced users seek in e-commerce applications. We used eye tracking method in evaluations. Eye movement data are obtained from the eye-tracking method and analyzed based on task completion time, number of fixations, as well as heat map and gaze plot measures. The results of the analysis show that the eye movements of participants' are too static in certain areas and their areas of interest are scattered in many different places. It has been determined that this causes users to fail to complete their transactions. According to the findings, we outlined the issues to improve the usability of e-commerce websites. Then we propose solutions to identify the issues. In this way, it is expected that e-commerce sites will be developed which will make experienced users more satisfied.
Keywords: E-commerce websites, eye tracking method, usability, website evaluations.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1267154 Different Views and Evaluations of IT Artifacts
Authors: Sameh Al-Natour, Izak Benbasat
Abstract:
The introduction of a multitude of new and interactive e-commerce information technology (IT) artifacts has impacted adoption research. Rather than solely functioning as productivity tools, new IT artifacts assume the roles of interaction mediators and social actors. This paper describes the varying roles assumed by IT artifacts, and proposes and distinguishes between four distinct foci of how the artifacts are evaluated. It further proposes a theoretical model that maps the different views of IT artifacts to four distinct types of evaluations.Keywords: IT adoption, IT artifacts, similarity, social actor.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1352153 Biomechanical Analysis of the Basic Classical Dance Jump – The Grand Jeté
Authors: M. Kalichová
Abstract:
The aim of this study was to analyse the most important parameters determining the quality of the motion structure of the basic classical dance jump – grand jeté.Research sample consisted of 8 students of the Dance Conservatory in Brno. Using the system Simi motion we performed a 3D kinematic analysis of the jump. On the basis of the comparison of structure quality and measured data of the grand jeté, we defined the optimal values of the relevant parameters determining the quality of the performance. The take-off speed should achieve about 2.4 m·s-1, the optimum take-off angle is 28 - 30º. The take-off leg should swing backward at the beginning of the flight phase with the minimum speed of 3.3 m·s-1.If motor abilities of dancers achieve the level necessary for optimal performance of a classical dance jump, there is room for certain variability of the structure of the dance jump.Keywords: biomechanical analysis, classical dance, grand jeté, jump
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 7882152 Influence of Calcium Intake Level to Osteoporptic Vertebral bone and Degenerated Disc in Biomechanical Study
Authors: Dae Gon Woo, Ji Hyung Park, Chi Hoon Kim, Tae Woo Lee, Beob Yi Lee, Han Sung Kim
Abstract:
The aim of the present study is to analyze the generation of osteoporotic vertebral bone induced by lack of calcium during growth period and analyze its effects for disc degeneration, based on biomechanical and histomorphometrical study. Mechanical and histomorphological characteristics of lumbar vertebral bones and discs of rats with calcium free diet (CFD) were detected and tracked by using high resolution in-vivo micro-computed tomography (in-vivo micro-CT), finite element (FE) and histological analysis. Twenty female Sprague-Dawley rats (6 weeks old, approximate weight 170g) were randomly divided into two groups (CFD group: 10, NOR group: 10). The CFD group was maintained on a refmed calcium-controlled semisynthetic diet without added calcium, to induce osteoporosis. All lumbar (L 1-L6) were scanned by using in vivo micro-CT with 35i.un resolution at 0, 4, 8 weeks to track the effects of CFD on the generation of osteoporosis. The fmdings of the present study indicated that calcium insufficiency was the main factor in the generation of osteoporosis and it induced lumbar vertebral disc degeneration. This study is a valuable experiment to firstly evaluate osteoporotic vertebral bone and disc degeneration induced by lack of calcium during growth period from a biomechanical and histomorphometrical point of view.
Keywords: Calcium free diet, Disc degeneration, Osteoporosis, in-vivo micro-CT, Finite element analysis, Histology.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1864151 Optimisation of a Dragonfly-Inspired Flapping Wing-Actuation System
Authors: Jia-Ming Kok, Javaan Chahl
Abstract:
An optimisation method using both global and local optimisation is implemented to determine the flapping profile which will produce the most lift for an experimental wing-actuation system. The optimisation method is tested using a numerical quasi-steady analysis. Results of an optimised flapping profile show a 20% increase in lift generated as compared to flapping profiles obtained by high speed cinematography of a Sympetrum frequens dragonfly. Initial optimisation procedures showed 3166 objective function evaluations. The global optimisation parameters - initial sample size and stage one sample size, were altered to reduce the number of function evaluations. Altering the stage one sample size had no significant effect. It was found that reducing the initial sample size to 400 would allow a reduction in computational effort to approximately 1500 function evaluations without compromising the global solvers ability to locate potential minima. To further reduce the optimisation effort required, we increase the local solver’s convergence tolerance criterion. An increase in the tolerance from 0.02N to 0.05N decreased the number of function evaluations by another 20%. However, this potentially reduces the maximum obtainable lift by up to 0.025N.
Keywords: Flapping wing, Optimisation, Quasi-steady model.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2403150 The Biomechanical Properties of the Different Modalities of Surgically Corrected Coarctation of the Aorta in Neonates and Infants
Authors: Elina Ligere, Valts Ozolins, Lauris Smits, Normunds Sikora, Ivars Melderis, Laila Feldmane, Aris Lacis, Vladimir Kasyanov
Abstract:
Biomechanical properties of infantile aorta in vitro in cases of different standard anastomoses: end-to-end (ETE), extended anastomosis end-to-end (EETE) and subclavian flap aortoplasty (SFA) used for surgical correction of coarctation were analyzed to detect the influence of the method on the biomechanics of infantile aorta and possible changes in haemodinamics. 10 specimens of native aorta, 3 specimens with ETE, 4 EEET and 3 SFA were investigated. The experiments showed a non-linear relationship between stress and strain in the infantile aorta, the modulus of elasticity of the aortic wall increased with the increase of inner pressure. In the case of anastomosis end-to-end the modulus was almost constant, relevant to the modulus of elasticity of the aorta with the inner pressure 100-120 mmHg. The anastomoses EETE and SFA showed elastic properties closer to native aorta, the stiffness of ETE did not change with the changes in inner pressure.Keywords: biomechanics, coarctation, mechanical properties, neonatal aorta
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2009149 Quantitative Indicator of Abdominal Aortic Aneurysm Rupture Risk Based on its Geometric Parameters
Authors: Guillermo Vilalta, Félix Nieto, Carlos Vaquero, José A. Vilalta
Abstract:
Abdominal aortic aneurysms rupture (AAAs) is one of the main causes of death in the world. This is a very complex phenomenon that usually occurs “without previous warning". Currently, criteria to assess the aneurysm rupture risk (peak diameter and growth rate) can not be considered as reliable indicators. In a first approach, the main geometric parameters of aneurysms have been linked into five biomechanical factors. These are combined to obtain a dimensionless rupture risk index, RI(t), which has been validated preliminarily with a clinical case and others from literature. This quantitative indicator is easy to understand, it allows estimating the aneurysms rupture risks and it is expected to be able to identify the one in aneurysm whose peak diameter is less than the threshold value. Based on initial results, a broader study has begun with twelve patients from the Clinic Hospital of Valladolid-Spain, which are submitted to periodic follow-up examinations.
Keywords: AAA, rupture risk prediction, biomechanical factors, AAA geometric characterization.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1531148 Modelling of a Biomechanical Vertebral System for Seat Ejection in Aircrafts Using Lumped Mass Approach
Authors: R. Unnikrishnan, K. Shankar
Abstract:
In the case of high-speed fighter aircrafts, seat ejection is designed mainly for the safety of the pilot in case of an emergency. Strong windblast due to the high velocity of flight is one main difficulty in clearing the tail of the aircraft. Excessive G-forces generated, immobilizes the pilot from escape. In most of the cases, seats are ejected out of the aircrafts by explosives or by rocket motors attached to the bottom of the seat. Ejection forces are primarily in the vertical direction with the objective of attaining the maximum possible velocity in a specified period of time. The safe ejection parameters are studied to estimate the critical time of ejection for various geometries and velocities of flight. An equivalent analytical 2-dimensional biomechanical model of the human spine has been modelled consisting of vertebrae and intervertebral discs with a lumped mass approach. The 24 vertebrae, which consists of the cervical, thoracic and lumbar regions, in addition to the head mass and the pelvis has been designed as 26 rigid structures and the intervertebral discs are assumed as 25 flexible joint structures. The rigid structures are modelled as mass elements and the flexible joints as spring and damper elements. Here, the motions are restricted only in the mid-sagittal plane to form a 26 degree of freedom system. The equations of motions are derived for translational movement of the spinal column. An ejection force with a linearly increasing acceleration profile is applied as vertical base excitation on to the pelvis. The dynamic vibrational response of each vertebra in time-domain is estimated.
Keywords: Biomechanical model, lumped mass, seat ejection, vibrational response.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1051147 Biomechanical Findings in Patients with Bipartite Medial Cuneiforms
Authors: Aliza Lee, Mark Wilt, John Bonk, Scott Floyd, Bradley Hoffman, Karen Uchmanowicz
Abstract:
Bipartite medial cuneiforms are relatively rare but may play a significant role in biomechanical and gait abnormalities. It is believed that a bipartite medial cuneiform may alter the available range of motion due to its larger morphological variant, thus limiting the metatarsal plantarflexion needed to achieve adequate hallux dorsiflexion for normal gait. Radiographic and clinical assessment were performed on two patients who reported with foot pain along the first ray. Both patients had visible bipartite medial cuneiforms on MRI. Using gait plate and Metascan ™ analysis, both were noted to have four measurements far beyond the expected range. Medial and lateral heel peak pressure, hallux peak pressure, and 1st metatarsal peak pressure were all noted to be increased. These measurements are believed to be increased due to the hindrance placed on the available ROM of the first ray by the increased size of the medial cuneiform. A larger patient population would be needed to fully understand this developmental anomaly.
Keywords: Bipartite medial cuneiforms, cuneiform, developmental anomaly, gait abnormality.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 425146 A New SIR-based Model for Influenza Epidemic
Authors: Kang-Hung Yang, Jin-Yuan Hsu
Abstract:
In recent years, several severe large-scale influenza outbreaks happened in many countries, such as SARS in 2005 or H1N1 in 2009. Those influenza Epidemics have greatly impacts not only on people-s life and health, but medical systems in different countries. Although severe diseases are more experienced, they are not fully controlled. Governments have different policies to control the spreads of diseases. However, those policies have both positive and negative social or economical influence on people and society. Therefore, it is necessary and essential to develop an appropriate model for evaluations of policies. Consequently, a proper measure can be implemented to confront the diseases. The main goal of this study is to develop a SIR-based model for the further evaluations of the candidate policies during the influenza outbreaks.Keywords: SIR, influenza, systems dynamic model, H1N1
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2914145 The Impact of Culture on Tourists’ Evaluation of Hotel Service Experiences
Authors: Eid Alotaibi
Abstract:
The purpose of this study is to investigate the impact of tourists’ culture on perception and evaluation of hotel service experience and behavioral intentions. Drawing on Hofested’s cultural dimensions, this study seeks to further contribute towards understanding the effect of culture on perception and evaluation of hotels’ services, and whether there are differences between Saudi and European tourists’ perceptions of hotel services evaluation. A descriptive cross-sectional design was used in this study. Data were collected from tourists staying in five-star hotels in Saudi Arabia using the self-completion technique. The findings show that evaluations of hotel services differ from one culture to another. T-test results reveal that Saudis were more tolerant and reported significantly higher levels of satisfaction, were more likely to return and recommend the hotel, and perceived the price for the hotel stay as being good value for money as compared to their European counterparts. The sample was relatively small and specific to only five-star hotel evaluations. As a result, findings cannot be generalized to the wider tourist population. The results of this research have important implications for management within the Saudi hospitality industry. The study contributes to the tourist cultural theory by emphasizing the relative importance of cultural dimensions in-service evaluation. The author argues that no studies could be identified that compare Saudis and Europeans in their evaluations of their experiences staying at hotels. Therefore, the current study would enhance understanding of the effects of cultural factors on service evaluations and provide valuable input for international market segmentation and resource allocation in the Saudi hotel industry.
Keywords: Culture, tourist, service experience, hotel industry, Hofested’s cultural dimensions.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1099144 Sixth-Order Two-Point Efficient Family of Super-Halley Type Methods
Authors: Ramandeep Behl, S. S. Motsa
Abstract:
The main focus of this manuscript is to provide a highly efficient two-point sixth-order family of super-Halley type methods that do not require any second-order derivative evaluation for obtaining simple roots of nonlinear equations, numerically. Each member of the proposed family requires two evaluations of the given function and two evaluations of the first-order derivative per iteration. By using Mathematica-9 with its high precision compatibility, a variety of concrete numerical experiments and relevant results are extensively treated to confirm t he t heoretical d evelopment. From their basins of attraction, it has been observed that the proposed methods have better stability and robustness as compared to the other sixth-order methods available in the literature.Keywords: Basins of attraction, nonlinear equations, simple roots, Super-Halley.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 699143 An Overview of Evaluations Using Augmented Reality for Assembly Training Tasks
Authors: S. Werrlich, E. Eichstetter, K. Nitsche, G. Notni
Abstract:
Augmented Reality (AR) is a strong growing research topic in different training domains such as medicine, sports, military, education and industrial use cases like assembly and maintenance tasks. AR claims to improve the efficiency and skill-transfer of training tasks. This paper gives a comprehensive overview of evaluations using AR for assembly and maintenance training tasks published between 1992 and 2017. We search in a structured way in four different online databases and get 862 results. We select 17 relevant articles focusing on evaluating AR-based training applications for assembly and maintenance tasks. This paper also indicates design guidelines which are necessary for creating a successful application for an AR-based training. We also present five scientific limitations in the field of AR-based training for assembly tasks. Finally, we show our approach to solve current research problems using Design Science Research (DSR).
Keywords: Assembly, augmented reality, survey, training.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1927142 Usability and Functionality: A Comparison of Key Project Personnel's and Potential Users' Evaluations
Authors: F. Calisir, C. A. Gumussoy, A. E. Bayraktaroglu, E. Saygivar
Abstract:
Meeting users- requirements is one of predictors of project success. There should be a match between the expectations of the users and the perception of key project personnel with respect to usability and functionality. The aim of this study is to make a comparison of key project personnel-s and potential users- (customer representatives) evaluations of the relative importance of usability and functionality factors in a software design project. Analytical Network Process (ANP) was used to analyze the relative importance of the factors. The results show that navigation and interaction are the most significant factors,andsatisfaction and efficiency are the least important factors for both groups. Further, it can be concluded that having similar orders and scores of usability and functionality factors for both groups shows that key project personnel have captured the expectations and requirements of potential users accurately.
Keywords: Functionality, software design, usability.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1651141 A Comparison among Wolf Pack Search and Four other Optimization Algorithms
Authors: Shahla Shoghian, Maryam Kouzehgar
Abstract:
The main objective of this paper is applying a comparison between the Wolf Pack Search (WPS) as a newly introduced intelligent algorithm with several other known algorithms including Particle Swarm Optimization (PSO), Shuffled Frog Leaping (SFL), Binary and Continues Genetic algorithms. All algorithms are applied on two benchmark cost functions. The aim is to identify the best algorithm in terms of more speed and accuracy in finding the solution, where speed is measured in terms of function evaluations. The simulation results show that the SFL algorithm with less function evaluations becomes first if the simulation time is important, while if accuracy is the significant issue, WPS and PSO would have a better performance.Keywords: Wolf Pack Search, Particle Swarm Optimization, Continues Genetic Algorithm, Binary Genetic Algorithm, Shuffled Frog Leaping, Optimization.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3752140 Biomechanical Prediction of Veins and Soft Tissues beneath Compression Stockings Using Fluid-Solid Interaction Model
Authors: Chongyang Ye, Rong Liu
Abstract:
Elastic compression stockings (ECSs) have been widely applied in prophylaxis and treatment of chronic venous insufficiency of lower extremities. The medical function of ECS is to improve venous return and increase muscular pumping action to facilitate blood circulation, which is largely determined by the complex interaction between the ECS and lower limb tissues. Understanding the mechanical transmission of ECS along the skin surface, deeper tissues, and vascular system is essential to assess the effectiveness of the ECSs. In this study, a three-dimensional (3D) finite element (FE) model of the leg-ECS system integrated with a 3D fluid-solid interaction (FSI) model of the leg-vein system was constructed to analyze the biomechanical properties of veins and soft tissues under different ECS compression. The Magnetic Resonance Imaging (MRI) of the human leg was divided into three regions, including soft tissues, bones (tibia and fibula) and veins (peroneal vein, great saphenous vein, and small saphenous vein). The ECSs with pressure ranges from 15 to 26 mmHg (Classes I and II) were adopted in the developed FE-FSI model. The soft tissue was assumed as a Neo-Hookean hyperelastic model with the fixed bones, and the ECSs were regarded as an orthotropic elastic shell. The interfacial pressure and stress transmission were simulated by the FE model, and venous hemodynamics properties were simulated by the FSI model. The experimental validation indicated that the simulated interfacial pressure distributions were in accordance with the pressure measurement results. The developed model can be used to predict interfacial pressure, stress transmission, and venous hemodynamics exerted by ECSs and optimize the structure and materials properties of ECSs design, thus improving the efficiency of compression therapy.Keywords: Elastic compression stockings, fluid-solid interaction, tissue and vein properties, prediction.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 611139 Very-high-Precision Normalized Eigenfunctions for a Class of Schrödinger Type Equations
Authors: Amna Noreen , Kare Olaussen
Abstract:
We demonstrate that it is possible to compute wave function normalization constants for a class of Schr¨odinger type equations by an algorithm which scales linearly (in the number of eigenfunction evaluations) with the desired precision P in decimals.
Keywords: Eigenvalue problems, bound states, trapezoidal rule, poisson resummation.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 2855138 The Effects of Applying Wash and Green-A Syrups as Substitution of Sugar on Dough and Cake Properties
Authors: Banafsheh Aghamohammadi, Masoud Honarvar, Babak Ghiassi Tarzi
Abstract:
Usage of different components has been considered to improve the quality and nutritional properties of cakes in recent years. The effects of applying some sweeteners, instead of sugar, have been evaluated in cakes and many bread formulas up to now; but there has not been any research about the usage of by-products of sugar factories such as Wash and Green-A Syrups in cake formulas. In this research, the effects of substituting 25%, 50%, 75% and 100% of sugar with Wash and Green-A Syrups on some dough and cake properties, such as pH, viscosity, density, volume, weight loss, moisture, water activity, texture, staling, color and sensory evaluations, are studied. The results of these experiments showed that the pH values were not significantly different among any of the all cake batters and also most of the cake samples. Although differences among viscosity and specific gravity of all treatments were both significant and insignificant, these two parameters resulted in higher volume in all samples than the blank one. The differences in weight loss, moisture content and water activity of samples were insignificant. Evaluating of texture showed that the softness of most of samples is increased and the staling is decreased. Crumb color and sensory evaluations of samples were also affected by the replacement of sucrose with Wash and Green-A Syrups. According to the results, we can increase the shelf life and improve the quality and nutritional values of cake by using these kinds of syrups in the formulation.Keywords: Cake, green-A syrup, quality tests, sensory evaluation, wash syrup.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 967137 Relationship between Functional Gastrointestinal Disorders and Risk Factors: A Biomechanical Analysis
Authors: Dae Gon Woo, Han Sung Kim, Dohyung Lim, Dong Jin Seo, In Deok Kong, Chang Yong Ko
Abstract:
Functional gastrointestinal disorders (FGID) affect millions of people spread all age regardless of race and sex. Emotional stress and obesity have been associated with increased reporting of gastrointestinal (GI) symptoms, but the relationship between FGID and risk factors (emotional stress or obesity) is unclear. Our aim was to assess the changes of the mechanical characteristics on the gastrointestinal tracts of the mentally fatigued obese and normal rat models. Finally, using the physical characteristics with micro-indentation test, we made a close investigation into the relation between FGID and risk factors quantitatively.
Keywords: Functional gastrointestinal disorders, Risk Factors, Mechanical Characteristics, Gastrointestinal Tract.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 1618136 Empirical Analysis of Velocity Behavior for Collaborative Robots in Transient Contact Cases
Authors: C. Schneider, M. M. Seizmeir, T. Suchanek, M. Hutter-Mironovová, M. Bdiwi, M. Putz
Abstract:
In this paper, a suitable measurement setup is presented to conduct force and pressure measurements for transient contact cases at the example of lathe machine tending. Empirical measurements were executed on a selected collaborative robot’s behavior regarding allowable operating speeds under consideration of sensor- and workpiece-specific factors. Comparisons between the theoretic calculations proposed in ISO/TS 15066 and the practical measurement results reveal a basis for future research. With the created database, preliminary risk assessment and economic assessment procedures of collaborative machine tending cells can be facilitated.
Keywords: biomechanical thresholds, collaborative robots, force and pressure measurements, machine tending, transient contact
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 592135 Electromyography Activity of the Rectus Femoris and Biceps Femoris Muscles during Prostration and Squat Exercise
Authors: Mohd Safee M. K., Wan Abas W. A. B, Ibrahim F., Abu Osman N. A., Abdul Malik N. A.
Abstract:
This paper investigates the activity of the rectus femoris (RF) and biceps femoris (BF) in healthy subjects during salat (prostration) and specific exercise (squat exercise) using electromyography (EMG). A group of undergraduates aged between 19 to 25 years voluntarily participated in this study. The myoelectric activity of the muscles were recorded and analyzed. The finding indicated that there were contractions of the muscles during the salat and exercise with almost same EMG’s level. From the result, Wilcoxon’s Rank Sum test showed significant difference between prostration and squat exercise (p<0.05) but the differences was very small; RF (8.63%MVC) and BF (11.43%MVC). Therefore, salat may be useful in strengthening exercise and also in rehabilitation programs for lower limb activities. This pilot study conducted initial research into the biomechanical responses of human muscles in various positions of salat.
Keywords: Electromyography, exercise, muscle, salat.
Procedia APA BibTeX Chicago EndNote Harvard JSON MLA RIS XML ISO 690 PDF Downloads 3155