Search results for: robotic resection
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 391

Search results for: robotic resection

331 Safety and Efficacy of Laparoscopic D2 Gastrectomy for Advanced Gastric Cancers Single Unit Experience

Authors: S. M. P Manjula, Ishara Amarathunga, Aryan Nath Koura, Jaideepraj Rao

Abstract:

Background: Laparoscopic D2 Gastrectomy for non metastatic advanced Gastric cancer (AGC) has become a controversial topic as there are confronting ideas from experts in the field. Lack of consensus are mainly due to non feasibility of the dissection and safety and efficacy. Method: Data from all D2 Gastrectomies performed (both Subtotal and Total Gastrectomies) in our unit from 2009 December to 2013 December were retrospectively analysed. Computor database was prospectively maintained. Pathological stage two A (iiA) and above considered advanced Gastric cancers, who underwent curative intent D2 Gastrectomy were included for analysis(n=46). Four patients excluded from the study as peritoneal fluid cytology came positive for cancer cells and one patient exempted as microscopic resection margin positive(R1) after curative resection. Thirty day morbidity and mortality, operative time, lymph nodes harvest and survival (disease free and overall) analyzed. Results: Complete curative resection achieved in 40 patients. Mean age of the study population was 62.2 (32-88) and male to female ratio was 23: 17. Thirty day mortality (1/40) and morbidity (6/40). Average operative time 203.7 minutes (185- 400) and average lymphnodes harvest was 40.5 (18-91). Disease free survival of the AGC in this study population was 16.75 months (1-49). Average hospital stay was 6.8 days (3-31). Conclusion: Laparoscopic dissection is effective feasible and safe in AGC.

Keywords: laparoscopy, advanced gastric cancer, safety, efficacy

Procedia PDF Downloads 307
330 Timing of Ileostomy Closure Following Rectal Cancer Surgery at an Australian Regional Hospital

Authors: Tedman Cheuk-Yiu Chau, Xavier Harvey, Hung Nguyen

Abstract:

Defunctioning ileostomies are frequently used as an adjunct to low anterior resection in the surgical treatment of rectal cancer. Despite reducing the rate of clinically relevant anastomotic leak, the burden of defunctioning ileostomy is significant, with up to two-thirds of patients reporting stoma-related morbidity. International data have demonstrated an increased risk of bowel dysfunction and lower quality of life in patients with delayed closure (greater than six months post-surgery). While timely reversal is safe and cost-effective, the time to the reversal in Australian and New Zealand public hospitals is not described in the published literature. Thus, it is important to assess the current timeliness of ileostomy closure in the Australian regional context and examine the reasons for the delay. A retrospective analysis of ileostomy closure in Launceston General Hospital (LGH) patients treated with low/ultra low anterior resection for rectal cancer between 2012 and 2019 was undertaken. 94 cases of rectal adenocarcinoma undergoing ultralow anterior resection were examined over the years between 2012-2019. Amongst these, 21 cases (22.3%) were not reversed due to disease progress, death prior to reversal, or surgical complication. Demographics, disease status, surgical technique, and hospital inpatient events of these cases were examined. An average waiting time of 213.2 days was noted. Reasons for the delay include non-specified/prolonged hospital waiting time (54%), delayed or complicated chemotherapy course (13%), surgical complication (11%), advanced age, and frailty(5%). Complication of a delayed ileostomy reversal includes post-operation ileus and the development of an incisional hernia. We conclude that a delayed reversal of ileostomy can contribute to a higher incidence of stoma-related co-morbidities and contribute to a longer hospital stay and therefore use of public hospital resources.

Keywords: anterior resection, colorectal surgery, ileostomy reversal, rectal cancer

Procedia PDF Downloads 65
329 A System Architecture for Hand Gesture Control of Robotic Technology: A Case Study Using a Myo™ Arm Band, DJI Spark™ Drone, and a Staubli™ Robotic Manipulator

Authors: Sebastian van Delden, Matthew Anuszkiewicz, Jayse White, Scott Stolarski

Abstract:

Industrial robotic manipulators have been commonplace in the manufacturing world since the early 1960s, and unmanned aerial vehicles (drones) have only begun to realize their full potential in the service industry and the military. The omnipresence of these technologies in their respective fields will only become more potent in coming years. While these technologies have greatly evolved over the years, the typical approach to human interaction with these robots has not. In the industrial robotics realm, a manipulator is typically jogged around using a teach pendant and programmed using a networked computer or the teach pendant itself via a proprietary software development platform. Drones are typically controlled using a two-handed controller equipped with throttles, buttons, and sticks, an app that can be downloaded to one’s mobile device, or a combination of both. This application-oriented work offers a novel approach to human interaction with both unmanned aerial vehicles and industrial robotic manipulators via hand gestures and movements. Two systems have been implemented, both of which use a Myo™ armband to control either a drone (DJI Spark™) or a robotic arm (Stäubli™ TX40). The methodologies developed by this work present a mapping of armband gestures (fist, finger spread, swing hand in, swing hand out, swing arm left/up/down/right, etc.) to either drone or robot arm movements. The findings of this study present the efficacy and limitations (precision and ergonomic) of hand gesture control of two distinct types of robotic technology. All source code associated with this project will be open sourced and placed on GitHub. In conclusion, this study offers a framework that maps hand and arm gestures to drone and robot arm control. The system has been implemented using current ubiquitous technologies, and these software artifacts will be open sourced for future researchers or practitioners to use in their work.

Keywords: human robot interaction, drones, gestures, robotics

Procedia PDF Downloads 128
328 Time-Interval between Rectal Cancer Surgery and Reintervention for Anastomotic Leakage and the Effects of a Defunctioning Stoma: A Dutch Population-Based Study

Authors: Anne-Loes K. Warps, Rob A. E. M. Tollenaar, Pieter J. Tanis, Jan Willem T. Dekker

Abstract:

Anastomotic leakage after colorectal cancer surgery remains a severe complication. Early diagnosis and treatment are essential to prevent further adverse outcomes. In the literature, it has been suggested that earlier reintervention is associated with better survival, but anastomotic leakage can occur with a highly variable time interval to index surgery. This study aims to evaluate the time-interval between rectal cancer resection with primary anastomosis creation and reoperation, in relation to short-term outcomes, stratified for the use of a defunctioning stoma. Methods: Data of all primary rectal cancer patients that underwent elective resection with primary anastomosis during 2013-2019 were extracted from the Dutch ColoRectal Audit. Analyses were stratified for defunctioning stoma. Anastomotic leakage was defined as a defect of the intestinal wall or abscess at the site of the colorectal anastomosis for which a reintervention was required within 30 days. Primary outcomes were new stoma construction, mortality, ICU admission, prolonged hospital stay and readmission. The association between time to reoperation and outcome was evaluated in three ways: Per 2 days, before versus on or after postoperative day 5 and during primary versus readmission. Results: In total 10,772 rectal cancer patients underwent resection with primary anastomosis. A defunctioning stoma was made in 46.6% of patients. These patients had a lower anastomotic leakage rate (8.2% vs. 11.6%, p < 0.001) and less often underwent a reoperation (45.3% vs. 88.7%, p < 0.001). Early reoperations (< 5 days) had the highest complication and mortality rate. Thereafter the distribution of adverse outcomes was more spread over the 30-day postoperative period for patients with a defunctioning stoma. Median time-interval from primary resection to reoperation for defunctioning stoma patients was 7 days (IQR 4-14) versus 5 days (IQR 3-13 days) for no-defunctioning stoma patients. The mortality rate after primary resection and reoperation were comparable (resp. for defunctioning vs. no-defunctioning stoma 1.0% vs. 0.7%, P=0.106 and 5.0% vs. 2.3%, P=0.107). Conclusion: This study demonstrated that early reinterventions after anastomotic leakage are associated with worse outcomes (i.e. mortality). Maybe the combination of a physiological dip in the cellular immune response and release of cytokines following surgery, as well as a release of endotoxins caused by the bacteremia originating from the leakage, leads to a more profound sepsis. Another explanation might be that early leaks are not contained to the pelvis, leading to a more profound sepsis requiring early reoperations. Leakage with or without defunctioning stoma resulted in a different type of reinterventions and time-interval between surgery and reoperation.

Keywords: rectal cancer surgery, defunctioning stoma, anastomotic leakage, time-interval to reoperation

Procedia PDF Downloads 108
327 Piezoelectric Actuator for Controlling Robotics Organs

Authors: Lemoussi Somia, Ouali Mohammed, Zemirline Adel

Abstract:

In precision engineering, including precision positioning, micro-manipulation, robotic systems... a majority of these applications actuated by piezo stack used the compliant amplifier mechanism to amplifying motion and guiding it as needed utilize the flexibility of their components, in this paper, we present a novel approach introducing a symmetric structure comprising three stages, featuring rectangular flexure hinges with a compact size of 77mm×42mm×10mm. This design provides the capability for rotation, translation or a combination of both movements in both directions. The system allows for a displacement of 2107.5 μm when the input displacement of PZT is 50 μm while considering the material constraints of the aluminum alloy (7075 T6) which has a maximum admissible stress of 500 MPa However, our proposed design imposes additional constraints to ensure the stress remains below 361 MPa for optimal performance. These findings were obtained through finite element simulations conducted using ANSYS Workbench. Furthermore, our module facilitates precise control of various components within robotic systems, allowing for adjustable speeds based on specific requirements or desired outcomes.

Keywords: robotic, piezoelectric, compliant mechanism, flexure hinge

Procedia PDF Downloads 51
326 Rehabilitative Walking: The Development of a Robotic Walking Training Device Using Functional Electrical Stimulation for Treating Spinal Cord Injuries and Lower-Limb Paralysis

Authors: Chung Hyun Goh, Armin Yazdanshenas, X. Neil Dong, Yong Tai Wang

Abstract:

Physical rehabilitation is a necessary step in regaining lower body function after a partial paralysis caused by a spinal cord injury or a stroke. The purpose of this paper is to present the development and optimization of a training device that accurately recreates the motions in a gait cycle with the goal of rehabilitation for individuals with incomplete spinal cord injuries or who are victims of a stroke. A functional electrical stimulator was used in conjunction with the training device to stimulate muscle groups pertaining to rehabilitative walking. The feasibility and reliability of the design are presented. To validate the design functionality, motion analyses of the knee and ankle gait paths were made using motion capture systems. Key results indicate that the robotic walking training device provides a viable mode of physical rehabilitation.

Keywords: functional electrical stimulation, rehabilitative walking, robotic walking training device, spinal cord injuries

Procedia PDF Downloads 115
325 Strategy and Coarctation of the Aorta Repair

Authors: Shirin Jalili, Ramin Ghasemi Shayan

Abstract:

Coarctation of the aorta (CoA) may be a common (CHD), which is the seventh most common sort of CHD. Still, this is often likely a think little off since the determination may be deferred, indeed within the pediatric populace. The choice for surgical repair incorporates resection of the contracted section with end-to-end or end-to-side anastomosis, subclavian fold aortoplasty, resection, and join the intervention, or prosthetic fix aortoplasty. Drastically expanded end-to-end repair or switched subclavian fold aortoplasty can be utilized when the coarctation expands to the distal arch. Swell angioplasty can be a palliative choice sometime recently the conclusive redress. Its objective is to stabilize high-risk patients that cannot be submitted to quick surgical intercession, such as untimely newborns. For disconnected and discrete coarctations, it can, as a rule, be drawn nearer and repaired by means of cleared out thoracotomy, extraction of the infected aorta (coarctectomy), and remaking, ordinarily by amplified end-to-end anastomosis. In this article, we need to supply a diagram of current proposals and strategies utilized to picture coarctations of the aorta.

Keywords: coarctation of the aorta, congenital heart disease, strategies, surgical repair

Procedia PDF Downloads 134
324 Multi-objective Rationality Optimisation for Robotic-fabrication-oriented Free-form Timber Structure Morphology Design

Authors: Yiping Meng, Yiming Sun

Abstract:

The traditional construction industry is unable to meet the requirements for novel fabrication and construction. Automated construction and digital design have emerged as industry development trends that compensate for this shortcoming under the backdrop of Industrial Revolution 4.0. Benefitting from more flexible working space and more various end-effector tools compared to CNC methods, robot fabrication and construction techniques have been used in irregular architectural design. However, there is a lack of a systematic and comprehensive design and optimisation workflow considering geometric form, material, and fabrication methods. This paper aims to propose a design optimisation workflow for improving the rationality of a free-form timber structure fabricated by the robotic arm. Firstly, the free-form surface is described by NURBS, while its structure is calculated using the finite element analysis method. Then, by considering the characteristics and limiting factors of robotic timber fabrication, strain energy and robustness are set as optimisation objectives to optimise structural morphology by gradient descent method. As a result, an optimised structure with axial force as the main force and uniform stress distribution is generated after the structure morphology optimisation process. With the decreased strain energy and the improved robustness, the generated structure's bearing capacity and mechanical properties have been enhanced. The results prove the feasibility and effectiveness of the proposed optimisation workflow for free-form timber structure morphology design.

Keywords: robotic fabrication, free-form timber structure, Multi-objective optimisation, Structural morphology, rational design

Procedia PDF Downloads 165
323 An Audit of Restaging Transurethral Resection of Bladder Tumor (Re-TURBT) Quality in a District General Hospital

Authors: Rizwan Iqbal

Abstract:

Introduction: Re-TURBT has been recommended by international guidelines for patients with non-muscle invasive bladder cancer (NMIBC) who are deemed high-risk. Indications for re-TURBTs remain controversial and studies show mixed outcomes. It should be performed when the initial TURBT specimen lacks detrusor muscle, has tumor stage pT1 or G3/high-grade, or where resection is deemed incomplete. This ensures complete resection of tumors that have a high risk of recurrence as well as accurately identifying any tumors which have been upstaged. The aim of this audit was to evaluate the quality of re-TURBTs in a district general hospital. Method: Data were retrospectively collected from 31 patients who had re-TURBTs between April 2021 and September 2022. Data included baseline demographics, time from initial to re-TURBT, quality of operation note, presence of residual tumor, complications, and administration of chemotherapy within 24 hours of the initial TURBT. Data collection remains ongoing at the time of writing. Results: The mean age was 76 years old and 71.0% of patients were male. 32.3% of patients had their re-TURBT within six weeks and 32.3% had intravesical chemotherapy administered within 24 hours of the initial TURBT. 74.2% of initial TURBTs had detrusor muscle present in the specimen. 48.4% of patients had residual disease following re-TURBT. Just one patient had their pathology upstaged at re-TURBT. The use of the TURBT proforma on the operation note was variable, with 51.6% and 38.7% of surgeons using the proforma after the initial and re-TURBT. Conclusion: Re-TURBT improves bladder cancer staging and is necessary in patients who are deemed high-risk in order to identify any upstaging or recurrence of the disease.

Keywords: urology, bladder cancer, turbt, cancer

Procedia PDF Downloads 41
322 Adaptive Control Approach for an Unmanned Aerial Manipulator

Authors: Samah Riache, Madjid Kidouche

Abstract:

In this paper, we propose a nonlinear controller for Aerial Manipulator (AM) consists of a Quadrotor equipped with two degrees of freedom robotic arm. The kinematic and dynamic models were developed by considering the aerial manipulator as a coupled system. The proposed controller was designed using Nonsingular Terminal Sliding Mode Control. The objective of our approach is to improve performances and attenuate the chattering drawback using an adaptive algorithm in the discontinuous control part. Simulation results prove the effectiveness of the proposed control strategy compared with Sliding Mode Controller.

Keywords: adaptive algorithm, quadrotor, robotic arm, sliding mode control

Procedia PDF Downloads 149
321 A609 Modeling of AC Servomotor Using Genetic Algorithm and Tests for Control of a Robotic Joint

Authors: J. G. Batista, T. S. Santiago, E. A. Ribeiro, G. A. P. Thé

Abstract:

This work deals with parameter identification of permanent magnet motors, a class of ac motor which is particularly important in industrial automation due to characteristics like applications high performance, are very attractive for applications with limited space and reducing the need to eliminate because they have reduced size and volume and can operate in a wide speed range, without independent ventilation. By using experimental data and genetic algorithm we have been able to extract values for both the motor inductance and the electromechanical coupling constant, which are then compared to measure and/or expected values.

Keywords: modeling, AC servomotor, permanent magnet synchronous motor-PMSM, genetic algorithm, vector control, robotic manipulator, control

Procedia PDF Downloads 495
320 Why is the Recurrence Rate of Residual or Recurrent Disease Following Endoscopic Mucosal Resection (EMR) of the Oesophageal Dysplasia’s and T1 Tumours Higher in the Greater Midlands Cancer Network?

Authors: Harshadkumar Rajgor, Jeff Butterworth

Abstract:

Background: Barretts oesophagus increases the risk of developing oesophageal adenocarcinoma. Over the last 40 years, there has been a 6 fold increase in the incidence of oesophageal adenocarcinoma in the western world and the incidence rates are increasing at a greater rate than cancers of the colon, breast and lung. Endoscopic mucosal resection (EMR) is a relatively new technique being used by 2 centres in the greater midlands cancer network. EMR can be used for curative or staging purposes, for high-grade dysplasia’s and T1 tumours of the oesophagus. EMR is also suitable for those who are deemed high risk for oesophagectomy. EMR has a recurrence rate of 21% according to the Wiesbaden data. Method: A retrospective study of prospectively collected data was carried out involving 24 patients who had EMR for curative or staging purposes. Complications of residual or recurrent disease following EMR that required further treatment were investigated. Results: In 54% of cases residual or recurrent disease was suspected. 96% of patients were given clear and concise information regarding their diagnosis of high-grade dysplasia or T1 tumours. All 24 patients consulted the same specialist healthcare team. Conclusion: EMR is a safe and effective treatment for patients who have high-grade dysplasia and T1NO tumours. In 54% of cases residual or recurrent disease was suspected. Initially, only single resections were undertaken. Multiple resections are now being carried out to reduce the risk of recurrence. Complications from EMR remain low in this series and consisted of a single episode of post procedural bleeding.

Keywords: endoscopic mucosal resection, oesophageal dysplasia, T1 tumours, cancer network

Procedia PDF Downloads 297
319 A Brain Controlled Robotic Gait Trainer for Neurorehabilitation

Authors: Qazi Umer Jamil, Abubakr Siddique, Mubeen Ur Rehman, Nida Aziz, Mohsin I. Tiwana

Abstract:

This paper discusses a brain controlled robotic gait trainer for neurorehabilitation of Spinal Cord Injury (SCI) patients. Patients suffering from Spinal Cord Injuries (SCI) become unable to execute motion control of their lower proximities due to degeneration of spinal cord neurons. The presented approach can help SCI patients in neuro-rehabilitation training by directly translating patient motor imagery into walkers motion commands and thus bypassing spinal cord neurons completely. A non-invasive EEG based brain-computer interface is used for capturing patient neural activity. For signal processing and classification, an open source software (OpenVibe) is used. Classifiers categorize the patient motor imagery (MI) into a specific set of commands that are further translated into walker motion commands. The robotic walker also employs fall detection for ensuring safety of patient during gait training and can act as a support for SCI patients. The gait trainer is tested with subjects, and satisfactory results were achieved.

Keywords: brain computer interface (BCI), gait trainer, spinal cord injury (SCI), neurorehabilitation

Procedia PDF Downloads 131
318 Laparoscopic Curative Resection for Right-Sided Colonic Tumours: Initial Experience from a Cancer Hospital of a Developing Country

Authors: Awais Naeem, Osama Shakeel, Aamir Ali Syed, Shahid Khattak

Abstract:

Introduction: Laparoscopic right hemicolectomy is an advanced cancer surgery in today's era. The aim of this study was to evaluate the surgical and initial oncological outcomes after curative, laparoscopic resection of right sided colonic tumors. Also to compare our results with those of previous randomized trials. Methods And Procedures: We retrospectively analyzed the medical record files of all the patients who presented to our hospital with the diagnosis of right sided colon carcinoma from January 2012 to December 2017 and underwent laparoscopic right hemicolectomy. Demographics, operative findings and histopathological reports were all recorded on a preformed data sheet. All the analysis was performed on SPSS 20. Results: Total of 48 patients were included. There were 37 male and 11 female patients with mean age of 49.7 (range from 25 – 82). Mean hospital stay was 8.25 ± 3.17 days. Blood loss was 80mls and operative mean time was 240 minutes. Eighteen patients had extended right hemicolectomy. Median length of the specimen retrieved was 31cm (range, 14-59cm). Mean size of tumor was 6.44cm + 2.53. Total number of lymph nodes removed was 20.5 + 8.3. All had R0 resection. Post-operatively 2 patients had pelvic collection and there was no 30 day mortality. In 33 patients there was T3 disease, 5 had T2 and 10 had T4 disease. There was distant recurrence in 4 patients with peritoneal metastasis in 3 and liver metastasis in 1 patient. Forty-six patients are still alive and 44 are disease free. The mean follow-up period was 25.31 (12 to 60) months. Conclusion: Our early experience with Laparascopic Right hemicolectomy as a safe and oncologically feasible surgical option. We attained comparable surgical results with curative intent.

Keywords: right hemicolectomy, right sided colonic tumors, laparoscopic, curative intent

Procedia PDF Downloads 104
317 Effect of Psychosocial, Behavioural and Disease Characteristics on Health-Related Quality of Life after Breast Cancer Surgery: A Cross-Sectional Study of a Regional Australian Population

Authors: Lakmali Anthony, Madeline Gillies

Abstract:

Background Breast cancer (BC) is usually managed with surgical resection. Many outcomes traditionally used to define successful operative management, such as resection margin, do not adequately reflect patients’ experience. Patient-reported outcomes (PRO) such as Health-Related Quality of life (HRQoL) provide a means by which the impact of surgery for cancer can be reported in a patient-centered way. This exploratory cross-sectional study aims to; (1) describe postoperative HRQoL in patients who underwent primary resection in a regional Australian hospital; (2) describe the prevalence of anxiety, depression and clinically significant fear of cancer recurrence (FCR) in this population; and (3) identify demographic, psychosocial, disease and treatment factors associated with poorer self-reported HRQoL. Methods Patients who had resection of BC in a regional Australian hospital between 2015 and 2022 were eligible. Participants were asked to complete a survey designed to assess HRQoL, as well as validated instruments that assess several other psychosocial PROs hypothesized to be associated with HRQoL; emotional distress, fear of cancer recurrence, social support, dispositional optimism, body image and spirituality. Results Forty-six patients completed the survey. Clinically significant levels of FCR and emotional distress were present in this group. Many domains of HRQoL were significantly worse than an Australian reference population for BC. Demographic and disease factors associated with poor HRQoL included smoking and ongoing adjuvant systemic therapy. The primary operation was not associated with HRQoL for breast cancer. All psychosocial factors measured were associated with HRQoL. Conclusion HRQoL is an important outcome in surgery for both research and clinical practice. This study provides an overview of the quality of life in a regional Australian population of postoperative breast cancer patients and the factors that affect it. Understanding HRQoL and awareness of patients particularly vulnerable to poor outcomes should be used to aid the informed consent and shared decision-making process between surgeon and patient.

Keywords: breast cancer, surgery, quality of life, regional population

Procedia PDF Downloads 41
316 Evaluation of Role of Surgery in Management of Pediatric Germ Cell Tumors According to Risk Adapted Therapy Protocols

Authors: Ahmed Abdallatif

Abstract:

Background: Patients with malignant germ cell tumors have age distribution in two peaks, with the first one during infancy and the second after the onset of puberty. Gonadal germ cell tumors are the most common malignant ovarian tumor in females aged below twenty years. Sacrococcygeal and retroperitoneal abdominal tumors usually presents in a large size before the onset of symptoms. Methods: Patients with pediatric germ cell tumors presenting to Children’s Cancer Hospital Egypt and National Cancer Institute Egypt from January 2008 to June 2011 Patients underwent stratification according to risk into low, intermediate and high risk groups according to children oncology group classification. Objectives: Assessment of the clinicopathologic features of all cases of pediatric germ cell tumors and classification of malignant cases according to their stage, and the primary site to low, intermediate and high risk patients. Evaluation of surgical management in each group of patients focusing on surgical approach, the extent of surgical resection according to each site, ability to achieve complete surgical resection and perioperative complications. Finally, determination of the three years overall and disease-free survival in different groups and the relation to different prognostic factors including the extent of surgical resection. Results: Out of 131 cases surgically explored only 26 cases had re exploration with 8 cases explored for residual disease 9 cases for remote recurrence or metastatic disease and the other 9 cases for other complications. Patients with low risk kept under follow up after surgery, out of those of low risk group (48 patients) only 8 patients (16.5%) shifted to intermediate risk. There were 20 patients (14.6%) diagnosed as intermediate risk received 3 cycles of compressed (Cisplatin, Etoposide and Bleomycin) and all high risk group patients 69patients (50.4%) received chemotherapy. Stage of disease was strongly and significantly related to overall survival with a poorer survival in late stages (stage IV) as compared to earlier stages. Conclusion: Overall survival rate at 3 three years was (76.7% ± 5.4, 3) years EFS was (77.8 % ±4.0), however 3 years DFS was much better (89.8 ± 3.4) in whole study group with ovarian tumors had significantly higher Overall survival (90% ± 5.1). Event Free Survival analysis showed that Male gender was 3 times likely to have bad events than females. Patients who underwent incomplete resection were 4 times more than patients with complete resection to have bad events. Disease free survival analysis showed that Patients who underwent incomplete surgery were 18.8 times liable for recurrence compared to those who underwent complete surgery, and patients who were exposed to re-excision were 21 times more prone to recurrence compared to other patients.

Keywords: extragonadal, germ cell tumors, gonadal, pediatric

Procedia PDF Downloads 190
315 A Primary Care Diagnosis of Middle-Aged Men with Oral Cancer Who Underwent Extensive Resection and Flap Repair: A Case Report

Authors: Ching-Yi Huang, Pi-Fen Cheng, Hui-Zhu Chen, Shi Ting Huang, Heng-Hua Wang

Abstract:

This is a case of oral cancer after extensive resection and modified right lateral neck lymph node dissection followed by reconstruction with a skin flap. The nursing period lasted From September 25 to October 3, 2017, through observation, interview, physical assessment, and medical record review, the author identified the following nursing problems: acute pain, impaired oral mucous membrane, and body image change. During the nursing period, the author provided individual and overall nursing care and established mutual trust through the use of empathy. Author listened and eased the patient's physical indisposition, such as wound pain, we use medications and acupuncture massage to relieve pain. However, for oral mucosa change caused by surgery, provide continuous and complete oral care and oral exercise training to improve oral mucosal healing and restore swallowing function. In the body-image changes, guided him to express his feeling after the body-image change, and enhanced support and from the family, and encouraged him to attend head and neck cancer survivor alliance which allowed the patient to accept the altered body image and reaffirm self-worth. Hopefully, through sharing this nursing experience will help to the nursing care quality of nursing care for oral cancer patients after extensive resection and modified right lateral neck lymph node dissection followed by reconstruction with a skin flap.

Keywords: oral cancer, acute pain, impaired oral mucous membrane, body image change

Procedia PDF Downloads 155
314 Visual and Chemical Servoing of a Hexapod Robot in a Confined Environment Using Jacobian Estimator

Authors: Guillaume Morin-Duponchelle, Ahmed Nait Chabane, Benoit Zerr, Pierre Schoesetters

Abstract:

Industrial inspection can be achieved through robotic systems, allowing visual and chemical servoing. A popular scheme for visual servo-controlled robotic is the image-based servoing sys-tems. In this paper, an approach of visual and chemical servoing of a hexapod robot using a visual and chemical Jacobian matrix are proposed. The basic idea behind the visual Jacobian matrix is modeling the differential relationship between the camera system and the robotic control system to detect and track accurately points of interest in confined environments. This approach allows the robot to easily detect and navigates to the QR code or seeks a gas source localization using surge cast algorithm. To track the QR code target, a visual servoing based on Jacobian matrix is used. For chemical servoing, three gas sensors are embedded on the hexapod. A Jacobian matrix applied to the gas concentration measurements allows estimating the direction of the main gas source. The effectiveness of the proposed scheme is first demonstrated on simulation. Finally, a hexapod prototype is designed and built and the experimental validation of the approach is presented and discussed.

Keywords: chemical servoing, hexapod robot, Jacobian matrix, visual servoing, navigation

Procedia PDF Downloads 100
313 A Wearable Fluorescence Imaging Device for Intraoperative Identification of Human Brain Tumors

Authors: Guoqiang Yu, Mehrana Mohtasebi, Jinghong Sun, Thomas Pittman

Abstract:

Malignant glioma (MG) is the most common type of primary malignant brain tumor. Surgical resection of MG remains the cornerstone of therapy, and the extent of resection correlates with patient survival. A limiting factor for resection, however, is the difficulty in differentiating the tumor from normal tissue during surgery. Fluorescence imaging is an emerging technique for real-time intraoperative visualization of MGs and their boundaries. However, most clinical-grade neurosurgical operative microscopes with fluorescence imaging ability are hampered by low adoption rates due to high cost, limited portability, limited operation flexibility, and lack of skilled professionals with technical knowledge. To overcome the limitations, we innovatively integrated miniaturized light sources, flippable filters, and a recording camera to the surgical eye loupes to generate a wearable fluorescence eye loupe (FLoupe) device for intraoperative imaging of fluorescent MGs. Two FLoupe prototypes were constructed for imaging of Fluorescein and 5-aminolevulinic acid (5-ALA), respectively. The wearable FLoupe devices were tested on tumor-simulating phantoms and patients with MGs. Comparable results were observed against the standard neurosurgical operative microscope (PENTERO® 900) with fluorescence kits. The affordable and wearable FLoupe devices enable visualization of both color and fluorescence images with the same quality as the large and expensive stationary operative microscopes. The wearable FLoupe device allows for a greater range of movement, less obstruction, and faster/easier operation. Thus, it reduces surgery time and is more easily adapted to the surgical environment than unwieldy neurosurgical operative microscopes.

Keywords: fluorescence guided surgery, malignant glioma, neurosurgical operative microscope, wearable fluorescence imaging device

Procedia PDF Downloads 27
312 The Application of Robotic Surgical Approaches in the Management of Midgut Neuroendocrine Tumours: A Systematic Review

Authors: Jatin Sridhar Naidu, Aryan Arora, Zainab Shafiq, Reza Mirnezami

Abstract:

Background: Robotic-assisted surgery (RAS) promises good outcomes in midgut adenocarcinoma surgery. However, its effectiveness in midgut neuroendocrine tumours (MNETs) is unknown. This study aimed to assess the current use, user interface, and any emerging developments of RAS in MNET treatment using the literature available. Methods: This review was carried out using PRISMA guidelines. MEDLINE, EMBASE, and Web of Science were searched on 22nd October 2022. All studies reporting primary data on robotic surgery in midgut neuroendocrine tumours or carcinoid tumours were included. The midgut was defined to be from the duodenojejunal flexure to the splenic flexure. Methodological quality was assessed using the Joanna Briggs critical appraisal tool. Results: According to our systematic review protocol, nineteen studies were selected. A total of twenty-six patients were identified. RAS was used for right colectomies, right hemicolectomies, ileal resections, caecal resections, intracorporeal anastomoses, and complete mesocolic excisions. It offered an optimal user-interface with enhanced visuals, fine dexterity, and ergonomic work position. Innovative developments in tumour-healthy tissue boundary and vasculature visualisation were reported. Conclusion: RAS for MNETs is safe and feasible, although the evidence base is limited. We recommend large prospective-randomised controlled trials comparing it with laparoscopy and open surgery. Developments in intraoperative contrast dyes and tumour-specific probes are very promising.

Keywords: robotic surgery, colorectal surgery, neuroendocrine neoplasms, midgut neoplasms

Procedia PDF Downloads 49
311 Design of Ultra-Light and Ultra-Stiff Lattice Structure for Performance Improvement of Robotic Knee Exoskeleton

Authors: Bing Chen, Xiang Ni, Eric Li

Abstract:

With the population ageing, the number of patients suffering from chronic diseases is increasing, among which stroke is a high incidence for the elderly. In addition, there is a gradual increase in the number of patients with orthopedic or neurological conditions such as spinal cord injuries, nerve injuries, and other knee injuries. These diseases are chronic, with high recurrence and complications, and normal walking is difficult for such patients. Nowadays, robotic knee exoskeletons have been developed for individuals with knee impairments. However, the currently available robotic knee exoskeletons are generally developed with heavyweight, which makes the patients uncomfortable to wear, prone to wearing fatigue, shortening the wearing time, and reducing the efficiency of exoskeletons. Some lightweight materials, such as carbon fiber and titanium alloy, have been used for the development of robotic knee exoskeletons. However, this increases the cost of the exoskeletons. This paper illustrates the design of a new ultra-light and ultra-stiff truss type of lattice structure. The lattice structures are arranged in a fan shape, which can fit well with circular arc surfaces such as circular holes, and it can be utilized in the design of rods, brackets, and other parts of a robotic knee exoskeleton to reduce the weight. The metamaterial is formed by continuous arrangement and combination of small truss structure unit cells, which changes the diameter of the pillar section, geometrical size, and relative density of each unit cell. It can be made quickly through additive manufacturing techniques such as metal 3D printing. The unit cell of the truss structure is small, and the machined parts of the robotic knee exoskeleton, such as connectors, rods, and bearing brackets, can be filled and replaced by gradient arrangement and non-uniform distribution. Under the condition of satisfying the mechanical properties of the robotic knee exoskeleton, the weight of the exoskeleton is reduced, and hence, the patient’s wearing fatigue is relaxed, and the wearing time of the exoskeleton is increased. Thus, the efficiency and wearing comfort, and safety of the exoskeleton can be improved. In this paper, a brief description of the hardware design of the prototype of the robotic knee exoskeleton is first presented. Next, the design of the ultra-light and ultra-stiff truss type of lattice structures is proposed, and the mechanical analysis of the single-cell unit is performed by establishing the theoretical model. Additionally, simulations are performed to evaluate the maximum stress-bearing capacity and compressive performance of the uniform arrangement and gradient arrangement of the cells. Finally, the static analysis is performed for the cell-filled rod and the unmodified rod, respectively, and the simulation results demonstrate the effectiveness and feasibility of the designed ultra-light and ultra-stiff truss type of lattice structures. In future studies, experiments will be conducted to further evaluate the performance of the designed lattice structures.

Keywords: additive manufacturing, lattice structures, metamaterial, robotic knee exoskeleton

Procedia PDF Downloads 73
310 IT-Based Global Healthcare Delivery System: An Alternative Global Healthcare Delivery System

Authors: Arvind Aggarwal

Abstract:

We have developed a comprehensive global healthcare delivery System based on information technology. It has medical consultation system where a virtual consultant can give medical consultation to the patients and Doctors at the digital medical centre after reviewing the patient’s EMR file consisting of patient’s history, investigations in the voice, images and data format. The system has the surgical operation system too, where a remote robotic consultant can conduct surgery at the robotic surgical centre. The instant speech and text translation is incorporated in the software where the patient’s speech and text (language) can be translated into the consultant’s language and vice versa. A consultant of any specialty (surgeon or Physician) based in any country can provide instant health care consultation, to any patient in any country without loss of time. Robotic surgeons based in any country in a tertiary care hospital can perform remote robotic surgery, through patient friendly telemedicine and tele-surgical centres. The patient EMR, financial data and data of all the consultants and robotic surgeons shall be stored in cloud. It is a complete comprehensive business model with healthcare medical and surgical delivery system. The whole system is self-financing and can be implemented in any country. The entire system uses paperless, filmless techniques. This eliminates the use of all consumables thereby reduces substantial cost which is incurred by consumables. The consultants receive virtual patients, in the form of EMR, thus the consultant saves time and expense to travel to the hospital to see the patients. The consultant gets electronic file ready for reporting & diagnosis. Hence time spent on the physical examination of the patient is saved, the consultant can, therefore, spend quality time in studying the EMR/virtual patient and give his instant advice. The time consumed per patient is reduced and therefore can see more number of patients, the cost of the consultation per patients is therefore reduced. The additional productivity of the consultants can be channelized to serve rural patients devoid of doctors.

Keywords: e-health, telemedicine, telecare, IT-based healthcare

Procedia PDF Downloads 150
309 Bioarm, a Prothesis without Surgery

Authors: J. Sagouis, A. Chamel, E. Carre, C. Casasreales, G. Rudnik, M. Cerdan

Abstract:

Robotics provides answers to amputees. The most expensive solutions surgically connect the prosthesis to nerve endings. There are also several types of non-invasive technologies that recover nerve messages passing through the muscles. After analyzing these messages, myoelectric prostheses perform the desired movement. The main goal is to avoid all surgeries, which can be heavy and offer cheaper alternatives. For an amputee, we use valid muscles to recover the electrical signal involved in a muscle movement. EMG sensors placed on the muscle allows us to measure a potential difference, which our program transforms into control for a robotic arm with two degrees of freedom. We have shown the feasibility of non-invasive prostheses with two degrees of freedom. Signal analysis and an increase in degrees of freedom is still being improved.

Keywords: prosthesis, electromyography (EMG), robotic arm, nerve message

Procedia PDF Downloads 229
308 Robotic Exoskeleton Response During Infant Physiological Knee Kinematics

Authors: Breanna Macumber, Victor A. Huayamave, Emir A. Vela, Wangdo Kim, Tamara T. Chamber, Esteban Centeno

Abstract:

Spina bifida is a type of neural tube defect that affects the nervous system and can lead to problems such as total leg paralysis. Treatment requires physical therapy and rehabilitation. Robotic exoskeletons have been used for rehabilitation to train muscle movement and assist in injury recovery; however, current models focus on the adult populations and not on the infant population. The proposed framework aims to couple a musculoskeletal infant model with a robotic exoskeleton using vacuum-powered artificial muscles to provide rehabilitation to infants affected by spina bifida. The study that drove the input values for the robotic exoskeleton used motion capture technology to collect data from the spontaneous kicking movement of a 2.4-month-old infant lying supine. OpenSim was used to develop the musculoskeletal model, and Inverse kinematics was used to estimate hip joint angles. A total of 4 kicks (A, B, C, D) were selected, and the selection was based on range, transient response, and stable response. Kicks had at least 5° of range of motion with a smooth transient response and a stable period. The robotic exoskeleton used a Vacuum-Powered Artificial Muscle (VPAM) the structure comprised of cells that were clipped in a collapsed state and unclipped when desired to simulate infant’s age. The artificial muscle works with vacuum pressure. When air is removed, the muscle contracts and when air is added, the muscle relaxes. Bench testing was performed using a 6-month-old infant mannequin. The previously developed exoskeleton worked really well with controlled ranges of motion and frequencies, which are typical of rehabilitation protocols for infants suffering with spina bifida. However, the random kicking motion in this study contained high frequency kicks and was not able to accurately replicate all the investigated kicks. Kick 'A' had a greater error when compared to the other kicks. This study has the potential to advance the infant rehabilitation field.

Keywords: musculoskeletal modeling, soft robotics, rehabilitation, pediatrics

Procedia PDF Downloads 77
307 Concept of a Low Cost Gait Rehabilitation Robot for Children with Neurological Dysfunction

Authors: Mariana Volpini, Volker Bartenbach, Marcos Pinotti, Robert Riener

Abstract:

Restoration of gait ability is an important task in the rehabilitation of people with neurological disorders presenting a great impact in the quality of life of an individual. Based on the motor learning concept, robotic assisted treadmill training has been introduced and found to be a feasible and promising therapeutic option in neurological rehabilitation but unfortunately it is not available for most patients in developing countries due to the high cost. This paper presents the concept of a low cost rehabilitation robot to help consolidate the robotic-assisted gait training as a reality in clinical practice in most countries. This work indicates that it is possible to build a simpler rehabilitation device respecting the physiological trajectory of the ankle.

Keywords: bioengineering, gait therapy, low cost rehabilitation robot, rehabilitation robotics

Procedia PDF Downloads 407
306 Development of 3D Laser Scanner for Robot Navigation

Authors: Ali Emre Öztürk, Ergun Ercelebi

Abstract:

Autonomous robotic systems needs an equipment like a human eye for their movement. Robotic camera systems, distance sensors and 3D laser scanners have been used in the literature. In this study a 3D laser scanner has been produced for those autonomous robotic systems. In general 3D laser scanners are using 2 dimension laser range finders that are moving on one-axis (1D) to generate the model. In this study, the model has been obtained by a one-dimensional laser range finder that is moving in two –axis (2D) and because of this the laser scanner has been produced cheaper. Furthermore for the laser scanner a motor driver, an embedded system control board has been used and at the same time a user interface card has been used to make the communication between those cards and computer. Due to this laser scanner, the density of the objects, the distance between the objects and the necessary path ways for the robot can be calculated. The data collected by the laser scanner system is converted in to cartesian coordinates to be modeled in AutoCAD program. This study shows also the synchronization between the computer user interface, AutoCAD and the embedded systems. As a result it makes the solution cheaper for such systems. The scanning results are enough for an autonomous robot but the scan cycle time should be developed. This study makes also contribution for further studies between the hardware and software needs since it has a powerful performance and a low cost.

Keywords: 3D laser scanner, embedded system, 1D laser range finder, 3D model

Procedia PDF Downloads 248
305 Systematic Review and Meta-Analysis of Mid-Term Survival, and Recurrent Mitral Regurgitation for Robotic-Assisted Mitral Valve Repair

Authors: Ramanen Sugunesegran, Michael L. Williams

Abstract:

Over the past two decades surgical approaches for mitral valve (MV) disease have evolved with the advent of minimally invasive techniques. Robotic mitral valve repair (RMVr) safety and efficacy has been well documented, however, mid- to long-term data are limited. The aim of this review was to provide a comprehensive analysis of the available mid- to long-term term data for RMVr. Electronic searches of five databases were performed to identify all relevant studies reporting minimum 5-year data on RMVr. Pre-defined primary outcomes of interest were overall survival, freedom from MV reoperation and freedom from moderate or worse mitral regurgitation (MR) at 5-years or more post-RMVr. A meta-analysis of proportions or means was performed, utilizing a random effects model, to present the data. Kaplan-Meier curves were aggregated using reconstructed individual patient data. Nine studies totaling 3,300 patients undergoing RMVr were identified. Rates of overall survival at 1-, 5- and 10-years were 99.2%, 97.4% and 92.3%, respectively. Freedom from MV reoperation at 8-years post RMVr was 95.0%. Freedom from moderate or worse MR at 7-years was 86.0%. Rates of early post-operative complications were low with only 0.2% all-cause mortality and 1.0% cerebrovascular accident. Reoperation for bleeding was low at 2.2% and successful RMVr was 99.8%. Mean intensive care unit and hospital stay were 22.4 hours and 5.2 days, respectively. RMVr is a safe procedure with low rates of early mortality and other complications. It can be performed with low complication rates in high volume, experienced centers. Evaluation of available mid-term data post-RMVr suggests favorable rates of overall survival, freedom from MV reoperation and freedom from moderate or worse MR recurrence.

Keywords: mitral valve disease, mitral valve repair, robotic cardiac surgery, robotic mitral valve repair

Procedia PDF Downloads 59
304 Smart Speed Bump

Authors: Mohammad Rahmani Rezaiyeh, Mojtaba Rahmani Rezaiyeh, Mehrdad Rahmani Rezaiyeh

Abstract:

Smart speed bump is a new invention and I am invented it. Smart speed bump is a system that can change the position of speed bumps either active or passive in necessary situations. The basic system of smart speed bumps is based on a robotic system which includes mechanic, electronic and artificial intelligence. The smart speed bump is capable of smart decision making and can change its position by anticipating the peak of terrific hours. It can be noted to the advantages of this system such as preventing the waste of petrol while crossing speed bumps, traffic management, accelerating, flowing and securing traffic, reducing accidents and judicial records.

Keywords: invention, smart, robotic system, speed bump, traffic, management

Procedia PDF Downloads 389
303 Image Segmentation of Visual Markers in Robotic Tracking System Based on Differential Evolution Algorithm with Connected-Component Labeling

Authors: Shu-Yu Hsu, Chen-Chien Hsu, Wei-Yen Wang

Abstract:

Color segmentation is a basic and simple way for recognizing the visual markers in a robotic tracking system. In this paper, we propose a new method for color segmentation by incorporating differential evolution algorithm and connected component labeling to autonomously preset the HSV threshold of visual markers. To evaluate the effectiveness of the proposed algorithm, a ROBOTIS OP2 humanoid robot is used to conduct the experiment, where five most commonly used color including red, purple, blue, yellow, and green in visual markers are given for comparisons.

Keywords: color segmentation, differential evolution, connected component labeling, humanoid robot

Procedia PDF Downloads 574
302 Neuron-Based Control Mechanisms for a Robotic Arm and Hand

Authors: Nishant Singh, Christian Huyck, Vaibhav Gandhi, Alexander Jones

Abstract:

A robotic arm and hand controlled by simulated neurons is presented. The robot makes use of a biological neuron simulator using a point neural model. The neurons and synapses are organised to create a finite state automaton including neural inputs from sensors, and outputs to effectors. The robot performs a simple pick-and-place task. This work is a proof of concept study for a longer term approach. It is hoped that further work will lead to more effective and flexible robots. As another benefit, it is hoped that further work will also lead to a better understanding of human and other animal neural processing, particularly for physical motion. This is a multidisciplinary approach combining cognitive neuroscience, robotics, and psychology.

Keywords: cell assembly, force sensitive resistor, robot, spiking neuron

Procedia PDF Downloads 321