Search results for: dose enhancement effect
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 16204

Search results for: dose enhancement effect

15844 Effect of Modulation Factors on Tomotherapy Plans and Their Quality Analysis

Authors: Asawari Alok Pawaskar

Abstract:

This study was aimed at investigating quality assurance (QA) done with IBA matrix, the discrepan­cies observed for helical tomotherapy plans. A selection of tomotherapy plans that initially failed the with Matrix process was chosen for this investigation. These plans failed the fluence analysis as assessed using gamma criteria (3%, 3 mm). Each of these plans was modified (keeping the planning constraints the same), beamlets rebatched and reoptimized. By increasing and decreasing the modula­tion factor, the fluence in a circumferential plane as measured with a diode array was assessed. A subset of these plans was investigated using varied pitch values. Factors for each plan that were examined were point doses, fluences, leaf opening times, planned leaf sinograms, and uniformity indices. In order to ensure that the treatment constraints remained the same, the dose-volume histograms (DVHs) of all the modulated plans were compared to the original plan. It was observed that a large increase in the modulation factor did not significantly improve DVH unifor­mity, but reduced the gamma analysis pass rate. This also increased the treatment delivery time by slowing down the gantry rotation speed which then increases the maximum to mean non-zero leaf open time ratio. Increasing and decreasing the pitch value did not substantially change treatment time, but the delivery accuracy was adversely affected. This may be due to many other factors, such as the complexity of the treatment plan and site. Patient sites included in this study were head and neck, breast, abdomen. The impact of leaf tim­ing inaccuracies on plans was greater with higher modulation factors. Point-dose measurements were seen to be less susceptible to changes in pitch and modulation factors. The initial modulation factor used by the optimizer, such that the TPS generated ‘actual’ modulation factor within the range of 1.4 to 2.5, resulted in an improved deliverable plan.

Keywords: dose volume histogram, modulation factor, IBA matrix, tomotherapy

Procedia PDF Downloads 151
15843 Green Synthesized Iron Oxide Nanoparticles: A Nano-Nutrient for the Growth and Enhancement of Flax (Linum usitatissimum L.) Plant

Authors: G. Karunakaran, M. Jagathambal, N. Van Minh, E. Kolesnikov, A. Gusev, O. V. Zakharova, E. V. Scripnikova, E. D. Vishnyakova, D. Kuznetsov

Abstract:

Iron oxide nanoparticles (Fe2O3NPs) are widely used in different applications due to its ecofriendly nature and biocompatibility. Hence, in this investigation, biosynthesized Fe2O3NPs influence on flax (Linum usitatissimum L.) plant was examined. The biosynthesized nanoparticles were found to be cubic phase which is confirmed by XRD analysis. FTIR analysis confirmed the presence of functional groups corresponding to the iron oxide nanoparticle. The elemental analysis also confirmed that the obtained nanoparticle is iron oxide nanoparticle. The scanning electron microscopy and the transmission electron microscopy confirm that the average particle size was around 56 nm. The effect of Fe2O3NPs on seed germination followed by biochemical analysis was carried out using standard methods. The results obtained after four days and 11 days of seed vigor studies showed that the seedling length (cm), average number of seedling with leaves, increase in root length (cm) was found to be enhanced on treatment with iron oxide nanoparticles when compared to control. A positive correlation was noticed with the dose of the nanoparticle and plant growth, which may be due to changes in metabolic activity. Hence, to evaluate the change in metabolic activity, peroxidase and catalase activities were estimated. It was clear from the observation that higher concentration of iron oxide nanoparticles (Fe2O3NPs 1000 mg/L) has enhanced peroxidase and catalase activities and in turn plant growth. Thus, this study clearly showed that biosynthesized iron oxide nanoparticles will be an effective nano-nutrient for agriculture applications.

Keywords: catalase, fertilizer, iron oxide nanoparticles, Linum usitatissimum L., nano-nutrient, peroxidase

Procedia PDF Downloads 356
15842 Direct and Moderating Effect of Religious Activities, Sustainability and Peer Support on Job Performance

Authors: Fahad Alam

Abstract:

Work stress directly affects job performance, specifically in a worse environment. Consequently, a social provision plays a crucial part for enhancement. Therefore, the current research investigates the direct and moderating effect between religious activities, sustainability and peer support on job performance at hospitals in Khyber PakhtunKhwa (KPK), Pakistan. Both primary and secondary data are collected through 261 questionnaires of medical employees from four district hospitals in Khyber PakhtunKhwa, Pakistan, in 2018. The analysis was carried out by SPSS16 and SMART PLS3, to test the direct effect of religious activities, sustainability and social support on job performance and the effect of moderating variable 'work environment' on job performance. The finding confirmed that direct and moderating variables play a significant positive effect among religious activities, sustainability and peer support on job performance, the variables help to diminish the strain level or the stress level, consequently helps in the job completed. Affirmative social approaches produce desirable effects on job performance. The research revealed that social provisions are significant triggers for superior practices. Moreover, the results are stimulating because some of the past literature revealed an insignificant correlation between social provision and performance. This study found that there is a significant relationship which persuades health care organizations.

Keywords: job performance, peer’s support, religious activities, sustainability, work environment

Procedia PDF Downloads 95
15841 A Lower Dose of Topiramate with Enough Antiseizure Effect: A Realistic Therapeutic Range of Topiramate

Authors: Seolah Lee, Yoohyk Jang, Soyoung Lee, Kon Chu, Sang Kun Lee

Abstract:

Objective: The International League Against Epilepsy (ILAE) currently suggests a topiramate serum level range of 5-20 mg/L. However, numerous institutions have observed substantial drug response at lower levels. This study aims to investigate the correlation between topiramate serum levels, drug responsiveness, and adverse events to establish a more accurate and tailored therapeutic range. Methods: We retrospectively analyzed topiramate serum samples collected between January 2017 and January 2022 at Seoul National University Hospital. Clinical data, including serum levels, antiseizure regimens, seizure frequency, and adverse events, were collected. Patient responses were categorized as "insufficient" (reduction in seizure frequency <50%) or "sufficient" (reduction ≥ 50%). Within the "sufficient" group, further subdivisions included seizure-free and tolerable seizure subgroups. A population pharmacokinetic model estimated serum levels from spot measurements. ROC curve analysis determined the optimal serum level cut-off. Results: A total of 389 epilepsy patients, with 555 samples, were reviewed, having a mean dose of 178.4±117.9 mg/day and a serum level of 3.9±2.8 mg/L. Out of the samples, only 5.6% (n=31) exhibited insufficient response, with a mean serum level of 3.6±2.5 mg/L. In contrast, 94.4% (n=524) of samples demonstrated sufficient response, with a mean serum level of 4.0±2.8 mg/L. This difference was not statistically significant (p = 0.45). Among the 78 reported adverse events, logistic regression analysis identified a significant association between ataxia and serum concentration (p = 0.04), with an optimal cut-off value of 6.5 mg/L. In the subgroup of patients receiving monotherapy, those in the tolerable seizure group exhibited a significantly higher serum level compared to the seizure-free group (4.8±2.0 mg/L vs 3.4±2.3 mg/L, p < 0.01). Notably, patients in the tolerable seizure group displayed a higher likelihood of progressing into drug-resistant epilepsy during follow-up visits compared to the seizure-free group. Significance: This study proposed an optimal therapeutic concentration for topiramate based on the patient's responsiveness to the drug and the incidence of adverse effects. We employed a population pharmacokinetic model and analyzed topiramate serum levels to recommend a serum level below 6.5 mg/L to mitigate the risk of ataxia-related side effects. Our findings also indicated that topiramate dose elevation is unnecessary for suboptimal responders, as the drug's effectiveness plateaus at minimal doses.

Keywords: topiramate, therapeutic range, low dos, antiseizure effect

Procedia PDF Downloads 33
15840 Synthesis of Flower-Like Silver Nanoarchitectures in Special Shapes and Their Applications in Surface-Enhanced Raman Scattering

Authors: Radka Králová, Libor Kvítek, Václav Ranc, Aleš Panáček, Radek Zbořil

Abstract:

Surface–Enhanced Raman Scattering (SERS) is an optical spectroscopic technique with very good potential for sensitive detection of substances. In this research, active substrates with high enhancement were provided. Novel silver particles (nanostructures) with high roughened, flower–like morphology were prepared by reduction of cation complex [Ag(NH3)2]+ in presence of sodium borohydride as reducing agent and stabilized polyacrylic acid. The products were characterized by UV/VIS absorption spectrophotometry. Special shapes of silver particles were determined by scanning electron microscopy (SEM) and transmission electron spectroscopy (TEM). Dispersions of this particle were put on fixed substrate to producing suitable layer for SERS. Adenine was applied as basic substance whose effect of enhancement on the layer of silver nanostructures was studied. By comparison with our work, the important influence of stabilizers, polyacrylic acid with various molecular weight and concentration, on the transfer of particles and formation of new structure was confirmed.

Keywords: metals, nanostructures, chemical reduction, Raman spectroscopy, optical properties

Procedia PDF Downloads 350
15839 The Effect of Interfacial Chemistry on Mechanical Properties of Epoxy Composites Containing Poly (Ether Ether Ketone) Grafted Multiwall Carbon Nanotubes

Authors: Prajakta Katti, Suryasarathi Bose, S. Kumar

Abstract:

In this work, carboxyl functionalized multiwall carbon nanotubes (a-MWNTs) covalently grafted with hydroxylated functionalized poly (ether ether ketone), HPEEK, which is miscible with the pre-polymer (epoxy) through the esterification reaction. The functionalized MWNTs were systematically characterized using spectroscopic techniques. The epoxy composites containing a-MWNTs and HPEEK grafted multiwall carbon nanotubes (HPEEK-g-MWNTs) were formulated using mechanical stirring coupled with a bath sonicator to improve the dispersion property of the nanoparticles and were subsequently cured at 80 ̊C and post cured at 180 ̊C. With the addition of 0.5 wt% of HPEEK-g-MWNTs, an impressive 44% enhancement in the storage modulus, 22% increase in tensile strength and 38% increase in fracture toughness was observed with respect to neat epoxy. In addition to these mechanical properties, the epoxy composites displayed significant enhancement in the hardness without reducing thermal stability. These improved properties were attributed to the tailored interface between HPEEK-MWNTs and epoxy matrix.

Keywords: epoxy, MWNTs, HPEEK-g-MWNTs, tensile properties, nanoindentation, fracture toughness

Procedia PDF Downloads 281
15838 Impact of Two Xenobiotics in Mosquitofish: Gambusia affinis: Several Approaches

Authors: Chouahda Salima, Soltani Noureddine

Abstract:

The present study is a part of biological control against mosquitoes. It aims to assess the impact of two xenobiotics (a selective insect growth regulator: halofenozide and heavy metals: cadmium, more toxic and widespread in the region) in mosquitofish: Gambusia affinis. Several approaches were examined: Acute toxicity of cadmium and halofenozide: The acute toxicity of cadmium and halofenozide was examined in juvenile and adult males and females of G. affinis at different concentrations, cadmium causes mortality of the species studied with a relation dose-response. In laboratory conditions, the impact of cadmium was determined on two biomarkers of environmental stress: glutathione and acetylcholinesterase. The results show that the juvenile followed by adult males are more susceptible than adult females, while the halofenozide does not have any effect on the mortality of juvenile and adult males and females of G.affinis. Chronic toxicity of cadmium and halofenozide: both xenobiotics were added to the water fish raising at different doses tested in juveniles and adults males and females during two months of experience. Growth and metric indices; results show that halofenozide added to the water juveniles of G. affinis has no effect on their growth (length and weight). On the other side, the cadmium at the dose 5 µg/L shows a higher toxicity against juvenile, where he appears to reduce significantly their linear growth and weight. In females, the both xenobiotics have significant effects on metric indices, but these effects are more important on the hepatosomatic index that the gonadosomatic index and the coefficient of condition. Biomarkers; acetylcholinesterase (AChE), glutathione S-transferase (GST) and glutathione (GSH) used in assessing of environmental stress were measured in juveniles and adults males and females. The response of these biomarkers reveals an inhibition of AChE specific activity, an induction of GST activity, and decrease of GSH rates in juveniles in the end of experiment and during chronic treatment adult males and females. The effect of these biomarkers is more pronounced in females compared to males and juveniles. These different biomarkers have a similar profile for the duration of exposure.

Keywords: gambusia affinis, insecticide, heavy metal, morphology, biomarkers, chronic toxicity, acute toxicity, pollution

Procedia PDF Downloads 286
15837 Numerical Investigation of Phase Change Materials (PCM) Solidification in a Finned Rectangular Heat Exchanger

Authors: Mounir Baccar, Imen Jmal

Abstract:

Because of the rise in energy costs, thermal storage systems designed for the heating and cooling of buildings are becoming increasingly important. Energy storage can not only reduce the time or rate mismatch between energy supply and demand but also plays an important role in energy conservation. One of the most preferable storage techniques is the Latent Heat Thermal Energy Storage (LHTES) by Phase Change Materials (PCM) due to its important energy storage density and isothermal storage process. This paper presents a numerical study of the solidification of a PCM (paraffin RT27) in a rectangular thermal storage exchanger for air conditioning systems taking into account the presence of natural convection. Resolution of continuity, momentum and thermal energy equations are treated by the finite volume method. The main objective of this numerical approach is to study the effect of natural convection on the PCM solidification time and the impact of fins number on heat transfer enhancement. It also aims at investigating the temporal evolution of PCM solidification, as well as the longitudinal profiles of the HTF circling in the duct. The present research undertakes the study of two cases: the first one treats the solidification of PCM in a PCM-air heat exchanger without fins, while the second focuses on the solidification of PCM in a heat exchanger of the same type with the addition of fins (3 fins, 5 fins, and 9 fins). Without fins, the stratification of the PCM from colder to hotter during the heat transfer process has been noted. This behavior prevents the formation of thermo-convective cells in PCM area and then makes transferring almost conductive. In the presence of fins, energy extraction from PCM to airflow occurs at a faster rate, which contributes to the reduction of the discharging time and the increase of the outlet air temperature (HTF). However, for a great number of fins (9 fins), the enhancement of the solidification process is not significant because of the effect of confinement of PCM liquid spaces for the development of thermo-convective flow. Hence, it can be concluded that the effect of natural convection is not very significant for a high number of fins. In the optimum case, using 3 fins, the increasing temperature of the HTF exceeds approximately 10°C during the first 30 minutes. When solidification progresses from the surfaces of the PCM-container and propagates to the central liquid phase, an insulating layer will be created in the vicinity of the container surfaces and the fins, causing a low heat exchange rate between PCM and air. As the solid PCM layer gets thicker, a progressive regression of the field of movements is induced in the liquid phase, thus leading to the inhibition of heat extraction process. After about 2 hours, 68% of the PCM became solid, and heat transfer was almost dominated by conduction mechanism.

Keywords: heat transfer enhancement, front solidification, PCM, natural convection

Procedia PDF Downloads 162
15836 Enhancing Children’s English Vocabulary Acquisition through Digital Storytelling at Happy Kids Kindergarten, Palembang, Indonesia

Authors: Gaya Tridinanti

Abstract:

Enhanching English vocabulary in early childhood is the main problem often faced by teachers. Thus, the purpose of this study was to determine the enhancement of children’s English vocabulary acquisition by using digital storytelling. This type of research was an action research. It consisted of a series of four activities done in repeated cycles: planning, implementation, observation, and reflection. The subject of the study consisted of 30 students of B group (5-6 years old) attending Happy Kids Kindergarten Palembang, Indonesia. This research was conducted in three cycles. The methods used for data collection were observation and documentation. Descriptive qualitative and quantitative methods were also used to analyse the data. The research showed that the digital storytelling learning activities could enhance the children’s English vocabulary acquisition. It is based on the data in which the enhancement in pre-cycle was 37% and 51% in Cycle I. In Cycle II it was 71% and in Cycle III it was 89.3%. The results showed an enhancement of about 14% from the pre-cycle to Cycle I, 20% from Cycle I to Cycle II, and enhancement of about 18.3% from Cycle II to Cycle III. The conclusion of this study suggests that digital storytelling learning method could enhance the English vocabulary acquisition of B group children at the Happy Kids Kindergarten Palembang. Therefore, digital storytelling can be considered as an alternative to improve English language learning in the classroom.

Keywords: acquisition, enhancing, digital storytelling, English vocabulary

Procedia PDF Downloads 240
15835 Dosimetric Analysis of Intensity Modulated Radiotherapy versus 3D Conformal Radiotherapy in Adult Primary Brain Tumors: Regional Cancer Centre, India

Authors: Ravi Kiran Pothamsetty, Radha Rani Ghosh, Baby Paul Thaliath

Abstract:

Radiation therapy has undergone many advancements and evloved from 2D to 3D. Recently, with rapid pace of drug discoveries, cutting edge technology, and clinical trials has made innovative advancements in computer technology and treatment planning and upgraded to intensity modulated radiotherapy (IMRT) which delivers in homogenous dose to tumor and normal tissues. The present study was a hospital-based experience comparing two different conformal radiotherapy techniques for brain tumors. This analytical study design has been conducted at Regional Cancer Centre, India from January 2014 to January 2015. Ten patients have been selected after inclusion and exclusion criteria. All the patients were treated on Artiste Siemens Linac Accelerator. The tolerance level for maximum dose was 6.0 Gyfor lenses and 54.0 Gy for brain stem, optic chiasm and optical nerves as per RTOG criteria. Mean and standard deviation values of PTV98%, PTV 95% and PTV 2% in IMRT were 93.16±2.9, 95.01±3.4 and 103.1±1.1 respectively; for 3DCRT were 91.4±4.7, 94.17±2.6 and 102.7±0.39 respectively. PTV max dose (%) in IMRT and 3D-CRT were 104.7±0.96 and 103.9±1.0 respectively. Maximum dose to the tumor can be delivered with IMRT with acceptable toxicity limits. Variables such as expertise, location of tumor, patient condition, and TPS influence the outcome of the treatment.

Keywords: brain tumors, intensity modulated radiotherapy (IMRT), three dimensional conformal radiotherapy (3D-CRT), radiation therapy oncology group (RTOG)

Procedia PDF Downloads 218
15834 Formulation and Evaluation of Niosomes Containing an Antihypertensive Drug

Authors: Sunil Kamboj, Suman Bala, Vipin Saini

Abstract:

Niosomes were formulated with an aim of enhancing the oral bioavailability of losartan potassium and formulated in different molar ratios of surfactant, cholesterol and dicetyl phosphate. The formulated niosomes were found in range of 54.98 µm to 107.85 µm in size. Formulations with 1:1 ratio of surfactant and cholesterol have shown maximum entrapment efficiencies. Niosomes with sorbitan monostearate showed maximum drug release and zero order release kinetics, at the end of 24 hours. The in vivo study has shown the significant enhancement in oral bioavailability of losartan potassium in rats, after a dose of 10 mg/kg. The average relative bioavailability in relation with pure drug solution was found 2.56, indicates more than two fold increase in oral bioavailability. A significant increment in MRT reflects the release retarding ability of the vesicles. In conclusion, niosomes could be a promising delivery of losartan potassium with improved oral bioavailability and prolonged release profiles.

Keywords: non-ionic surfactant vesicles, losartan potassium, oral bioavailability, controlled release

Procedia PDF Downloads 324
15833 Traditional Medicines Used for the Enhancement of Male Sexual Performance among the Indigenous Populations of Madhya Pradesh, India

Authors: A. N. Sharma

Abstract:

A traditional medicine comprises a knowledge system, practices related to the cure of various ailments that developed over generations by indigenous people or populations. The indigenous populations developed a unique understanding with wild plants, herbs, etc., and earned specialized knowledge of disease pattern and curative therapy-though hard experiences, common sense, trial, and error methods. Here, an attempt has been made to study the possible aspects of traditional medicines for the enhancement of male sexual performance among the indigenous populations of Madhya Pradesh, India. Madhya Pradesh state is situated more or less in the central part of India. The data have been collected from the 305 Bharias of Patalkot, traditional health service providers of Sagar district, and other indigenous populations of Madhya Pradesh. It may be concluded that sizable traditional medicines exist in Madhya Pradesh, India, for the enhancement of male sexual performance, which still awaits for scientific exploration and intensive pharmaceutical investigations.

Keywords: Bharias, indigenous, Madhya Pradesh, sexual performance, traditional medicine

Procedia PDF Downloads 126
15832 Effect Of Tephrosia purpurea (Family: Fabaceae) Formulations On Oviposition By The Pulse Beetle Callosobruchus chinensis Linn.

Authors: Priyanka Jain, Meera Srivastava

Abstract:

Among important insect pests of stored grains, the pulse beetle Callosobruchus chinensis Linn. (Coleoptera: Bruchidae) is one such pest causing considerable damage to stored pulses. An effort was made to screen plant Tephrosia purpurea (Family: Fabaceae) for its efficacy against the said pest. The pulse beetle C. chinensis was raised on green gram Vigna radiata in incubators maintained at 28 ± 2°C and 70% RH. Different formulations using plant parts (root, stem, leaf and fruit) were employed in the form of aqueous suspension, aqueous extract and ether extract and the treatments were made using different dose concentrations, namely 1%, 2.5%, 5% and 10%, besides normal and control. Specific number of adult insects were released in muslin cloth covered beakers containing weighed green gram grains and treated with different dose concentrations (w/v). Observations for the number of eggs laid by the pest insect C. chinensis was recorded after three days of treatment and it was observed that in general all the treatments of the plant resulted in significant decrease in the eggs laid (no/pair) by the insect, suggesting that the selected plant has a potential to be used against C. chinensis.

Keywords: Callosobruchus chinensis, egg laying, Tephrosia purpurea, Fabaceae, plant formulations

Procedia PDF Downloads 318
15831 Gene Expressions in Left Ventricle Heart Tissue of Rat after 150 Mev Proton Irradiation

Authors: R. Fardid, R. Coppes

Abstract:

Introduction: In mediastinal radiotherapy and to a lesser extend also in total-body irradiation (TBI) radiation exposure may lead to development of cardiac diseases. Radiation-induced heart disease is dose-dependent and it is characterized by a loss of cardiac function, associated with progressive heart cells degeneration. We aimed to determine the in-vivo radiation effects on fibronectin, ColaA1, ColaA2, galectin and TGFb1 gene expression levels in left ventricle heart tissues of rats after irradiation. Material and method: Four non-treatment adult Wistar rats as control group (group A) were selected. In group B, 4 adult Wistar rats irradiated to 20 Gy single dose of 150 Mev proton beam locally in heart only. In heart plus lung irradiate group (group C) 4 adult rats was irradiated by 50% of lung laterally plus heart radiation that mentioned in before group. At 8 weeks after radiation animals sacrificed and left ventricle heart dropped in liquid nitrogen for RNA extraction by Absolutely RNA® Miniprep Kit (Stratagen, Cat no. 400800). cDNA was synthesized using M-MLV reverse transcriptase (Life Technologies, Cat no. 28025-013). We used Bio-Rad machine (Bio Rad iQ5 Real Time PCR) for QPCR testing by relative standard curve method. Results: We found that gene expression of fibronectin in group C significantly increased compared to control group, but it was not showed significant change in group B compared to group A. The levels of gene expressions of Cola1 and Cola2 in mRNA did not show any significant changes between normal and radiation groups. Changes of expression of galectin target significantly increased only in group C compared to group A. TGFb1 expressions in group C more than group B showed significant enhancement compared to group A. Conclusion: In summary we can say that 20 Gy of proton exposure of heart tissue may lead to detectable damages in heart cells and may distribute function of them as a component of heart tissue structure in molecular level.

Keywords: gene expression, heart damage, proton irradiation, radiotherapy

Procedia PDF Downloads 461
15830 Proton Irradiation Testing on Commercial Enhancement Mode GaN Power Transistor

Authors: L. Boyaci

Abstract:

Two basic equipment of electrical power subsystem of space satellites are Power Conditioning Unit (PCU) and Power Distribution Unit (PDU). Today, the main switching element used in power equipment in satellites is silicon (Si) based radiation-hardened MOSFET. GaNFETs have superior performances over MOSFETs in terms of their conduction and switching characteristics. GaNFET has started to take MOSFET’s place in many applications in industry especially by virtue of its switching performances. If GaNFET can also be used in equipment for space applications, this would be great revolution for future space power subsystem designs. In this study, the effect of proton irradiation on Gallium Nitride based power transistors was investigated. Four commercial enhancement mode GaN power transistors from Efficient Power Conversion Corporation (EPC) are irradiated with 30MeV protons while devices are switching. Flux of 8.2x10⁹ protons/cm²/s is applied for 12.5 seconds to reach ultimate fluence of 10¹¹ protons/cm². Vgs-Ids characteristics are measured and recorded for each device before, during and after irradiation. It was observed that if there would be destructive events. Proton induced permanent damage on devices is not observed. All the devices remained healthy and continued to operate. For two of these devices, further irradiation is applied with same flux for 30 minutes up to a total fluence level of 1.476x10¹³ protons/cm². We observed that GaNFETs are fully functional under this high level of radiation and no destructive events and irreversible failures took place for transistors. Results reveal that irradiated GaNFET in this experiment has radiation tolerance under proton testing and very important candidate for being one of the future power switching element in space.

Keywords: enhancement mode GaN power transistors, proton irradiation effects, radiation tolerance

Procedia PDF Downloads 126
15829 Radiation Protection Assessment of the Emission of a d-t Neutron Generator: Simulations with MCNP Code and Experimental Measurements in Different Operating Conditions

Authors: G. M. Contessa, L. Lepore, G. Gandolfo, C. Poggi, N. Cherubini, R. Remetti, S. Sandri

Abstract:

Practical guidelines are provided in this work for the safe use of a portable d-t Thermo Scientific MP-320 neutron generator producing pulsed 14.1 MeV neutron beams. The neutron generator’s emission was tested experimentally and reproduced by MCNPX Monte Carlo code. Simulations were particularly accurate, even generator’s internal components were reproduced on the basis of ad-hoc collected X-ray radiographic images. Measurement campaigns were conducted under different standard experimental conditions using an LB 6411 neutron detector properly calibrated at three different energies, and comparing simulated and experimental data. In order to estimate the dose to the operator vs. the operating conditions and the energy spectrum, the most appropriate value of the conversion factor between neutron fluence and ambient dose equivalent has been identified, taking into account both direct and scattered components. The results of the simulations show that, in real situations, when there is no information about the neutron spectrum at the point where the dose has to be evaluated, it is possible - and in any case conservative - to convert the measured value of the count rate by means of the conversion factor corresponding to 14 MeV energy. This outcome has a general value when using this type of generator, enabling a more accurate design of experimental activities in different setups. The increasingly widespread use of this type of device for industrial and medical applications makes the results of this work of interest in different situations, especially as a support for the definition of appropriate radiation protection procedures and, in general, for risk analysis.

Keywords: instrumentation and monitoring, management of radiological safety, measurement of individual dose, radiation protection of workers

Procedia PDF Downloads 109
15828 Survey of Indoor Radon/Thoron Concentrations in High Lung Cancer Incidence Area in India

Authors: Zoliana Bawitlung, P. C. Rohmingliana, L. Z. Chhangte, Remlal Siama, Hming Chungnunga, Vanram Lawma, L. Hnamte, B. K. Sahoo, B. K. Sapra, J. Malsawma

Abstract:

Mizoram state has the highest lung cancer incidence rate in India due to its high-level consumption of tobacco and its products which is supplemented by the food habits. While smoking is mainly responsible for this incidence, the effect of inhalation of indoor radon gas cannot be discarded as the hazardous nature of this radioactive gas and its progenies on human population have been well-established worldwide where the radiation damage to bronchial cells eventually can be the second leading cause of lung cancer next to smoking. It is also known that the effect of radiation, however, small may be the concentration, cannot be neglected as they can bring about the risk of cancer incidence. Hence, estimation of indoor radon concentration is important to give a useful reference against radiation effects as well as establishing its safety measures and to create a baseline for further case-control studies. The indoor radon/thoron concentrations in Mizoram had been measured in 41 dwellings selected on the basis of spot gamma background radiation and construction type of the houses during 2015-2016. The dwellings were monitored for one year, in 4 months cycles to indicate seasonal variations, for the indoor concentration of radon gas and its progenies, outdoor gamma dose, and indoor gamma dose respectively. A time-integrated method using Solid State Nuclear Track Detector (SSNTD) based single entry pin-hole dosimeters were used for measurement of indoor Radon/Thoron concentration. Gamma dose measurements for indoor as well as outdoor were carried out using Geiger Muller survey meters. Seasonal variation of indoor radon/ thoron concentration was monitored. The results show that the annual average radon concentrations varied from 54.07 – 144.72 Bq/m³ with an average of 90.20 Bq/m³ and the annual average thoron concentration varied from 17.39 – 54.19 Bq/m³ with an average of 35.91 Bq/m³ which are below the permissible limit. The spot survey of gamma background radiation level varies between 9 to 24 µR/h inside and outside the dwellings throughout Mizoram which are all within acceptable limits. From the above results, there is no direct indication that radon/thoron is responsible for the high lung cancer incidence in the area. In order to find epidemiological evidence of natural radiations to high cancer incidence in the area, one may need to conduct a case-control study which is beyond this scope. However, the derived data of measurement will provide baseline data for further studies.

Keywords: background gamma radiation, indoor radon/thoron, lung cancer, seasonal variation

Procedia PDF Downloads 118
15827 Dose Saving and Image Quality Evaluation for Computed Tomography Head Scanning with Eye Protection

Authors: Yuan-Hao Lee, Chia-Wei Lee, Ming-Fang Lin, Tzu-Huei Wu, Chih-Hsiang Ko, Wing P. Chan

Abstract:

Computed tomography (CT) scan of the head is a good method for investigating cranial lesions. However, radiation-induced oxidative stress can be accumulated in the eyes and promote carcinogenesis and cataract. In this regard, we aimed to protect the eyes with barium sulfate shield(s) during CT scans and investigate the resultant image quality and radiation dose to the eye. Patients who underwent health examinations were selectively enrolled in this study in compliance with the protocol approved by the Ethics Committee of the Joint Institutional Review Board at Taipei Medical University. Participants’ brains were scanned with a water-based marker simultaneously by a multislice CT scanner (SOMATON Definition Flash) under a fixed tube current-time setting or automatic tube current modulation (TCM). The lens dose was measured by Gafchromic films, whose dose response curve was previously fitted using thermoluminescent dosimeters, with or without barium sulfate or bismuth-antimony shield laid above. For the assessment of image quality CT images at slice planes that exhibit the interested regions on the zygomatic, orbital and nasal bones of the head phantom as well as the water-based marker were used for calculating the signal-to-noise and contrast-to-noise ratios. The application of barium sulfate and bismuth-antimony shields decreased 24% and 47% of the lens dose on average, respectively. Under topogram-based TCM, the dose saving power of bismuth-antimony shield was mitigated whereas that of barium sulfate shield was enhanced. On the other hand, the signal-to-noise and contrast-to-noise ratios of DSCT images were decreased separately by barium sulfate and bismuth-antimony shield, resulting in an overall reduction of the CNR. In contrast, the integration of topogram-based TCM elevated signal difference between the ROIs on the zygomatic bones and eyeballs while preferentially decreasing the signal-to-noise ratios upon the use of barium sulfate shield. The results of this study indicate that the balance between eye exposure and image quality can be optimized by combining eye shields with topogram-based TCM on the multislice scanner. Eye shielding could change the photon attenuation characteristics of tissues that are close to the shield. The application of both shields on eye protection hence is not recommended for seeking intraorbital lesions.

Keywords: computed tomography, barium sulfate shield, dose saving, image quality

Procedia PDF Downloads 245
15826 Assessing Trainee Radiation Exposure in Fluoroscopy-Guided Procedures: An Analysis of Hp(3)

Authors: Ava Zarif Sanayei, Sedigheh Sina

Abstract:

During fluoroscopically guided procedures, healthcare workers, especially radiology trainees, are at risk of exposure to elevated radiation exposure. It is vital to prioritize their safety in such settings. However, there is limited data on their monthly or annual doses. This study aimed to evaluate the equivalent dose to the eyes of the student trainee, utilizing LiF: Mg, Ti (TLD-100) chips at the radiology department of a hospital in Shiraz, Iran. Initially, the dosimeters underwent calibration procedures with the assistance of ISO-PTW calibrated phantoms. Following this, a set of dosimeters was prepared To determine HP(3) value for a trainee involved in the main operation room and controlled area utilized for two months. Three TLD chips were placed in a holder and attached to her eyeglasses. Upon completion of the duration, the TLDs were read out using a Harshaw TLD reader. Results revealed that Hp(3) value was 0.31±0.04 mSv. Based on international recommendations, students in radiology training above 18 have an annual dose limit of 0.6 rem (6 mSv). Assuming a 12-month workload, staff radiation exposure stayed below the annual limit. However, the Trainee workload may vary due to different deeds. This study's findings indicate the need for consistent, precise dose monitoring in IR facilities. Students can undertake supervised internships for up to 500 hours, depending on their institution. These internships take place in health-focused environments offering radiology services, such as clinics, diagnostic imaging centers, and hospitals. Failure to do so might result in exceeding occupational radiation dose limits. A 0.5 mm lead apron effectively absorbs 99% of radiation. To ensure safety, technologists and staff need to wear this protective gear whenever they are in the room during procedures. Furthermore, maintaining a safe distance from the primary beam is crucial. In cases where patients need assistance and must be held for imaging, additional protective equipment, including lead goggles, gloves, and thyroid shields, should be utilized for optimal safety.

Keywords: annual dose limits, Hp(3), individual monitoring, radiation protection, TLD-100

Procedia PDF Downloads 41
15825 Numerical Heat Transfer Performance of Water-Based Graphene Nanoplatelets

Authors: Ahmad Amiri, Hamed K. Arzani, S. N. Kazi, B. T. Chew

Abstract:

Since graphene nanoplatelet (GNP) is a promising material due to desirable thermal properties, this paper is related to the thermophysical and heat transfer performance of covalently functionalized GNP-based water/ethylene glycol nanofluid through an annular channel. After experimentally measuring thermophysical properties of prepared samples, a computational fluid dynamics study has been carried out to examine the heat transfer and pressure drop of well-dispersed and stabilized nanofluids. The effect of concentration of GNP and Reynolds number at constant wall temperature boundary condition under turbulent flow regime on convective heat transfer coefficient has been investigated. Based on the results, for different Reynolds numbers, the convective heat transfer coefficient of the prepared nanofluid is higher than that of the base fluid. Also, the enhancement of convective heat transfer coefficient and thermal conductivity increase with the increase of GNP concentration in base-fluid. Based on the results of this investigation, there is a significant enhancement on the heat transfer rate associated with loading well-dispersed GNP in base-fluid.

Keywords: nanofluid, turbulent flow, forced convection flow, graphene, annular, annulus

Procedia PDF Downloads 334
15824 A Study on the Annual Doses Received by the Workers of Some Medical Practices

Authors: Eltayeb Hamad Elneel Yousif

Abstract:

This paper describes occupational radiation doses of workers in non-destructive testing (NDT) and some medical practices during the year 2007. The annual doses received by the workers of a public hospital are presented in this report. The Department is facilitated with HARSHAW Reader model 6600 and assigned the rule of personal monitoring to contribute in controlling and reducing the doses received by radiation workers. TLD cards with two TLD chips type LiF: Mg, Ti (TLD-100) were calibrated to measure the personal dose equivalent Hp(10). Around 150 medical radiation workers were monitored throughout the year. Each worker received a single TLD card worn on the chest above lead apron and returned for laboratory reading every two months. The average annual doses received by the workers of radiotherapy, nuclear medicine and diagnostic radiology were evaluated. The annual doses for individual radiation workers ranged between 0.55-4.42 mSv, 0.48-1.86 mSv, and 0.48-0.91 mSv for the workers of radiotherapy, nuclear medicine and diagnostic radiology, respectively. The mean dose per worker was 1.29±1, 1.03±0.4, and 0.69±0.2 mSv, respectively. The results showed compliance with international dose limits. Our results reconfirm the importance of personal dosimetry service in assuring the radiation protection of medical staff in developing countries.

Keywords: radiation medicine, non-destructive testing, TLD, public hospital

Procedia PDF Downloads 349
15823 Investigation of Threshold Voltage Shift in Gamma Irradiated N-Channel and P-Channel MOS Transistors of CD4007

Authors: S. Boorboor, S. A. H. Feghhi, H. Jafari

Abstract:

The ionizing radiations cause different kinds of damages in electronic components. MOSFETs, most common transistors in today’s digital and analog circuits, are severely sensitive to TID damage. In this work, the threshold voltage shift of CD4007 device, which is an integrated circuit including P-channel and N-channel MOS transistors, was investigated for low dose gamma irradiation under different gate bias voltages. We used linear extrapolation method to extract threshold voltage from ID-VG characteristic curve. The results showed that the threshold voltage shift was approximately 27.5 mV/Gy for N-channel and 3.5 mV/Gy for P-channel transistors at the gate bias of |9 V| after irradiation by Co-60 gamma ray source. Although the sensitivity of the devices under test were strongly dependent to biasing condition and transistor type, the threshold voltage shifted linearly versus accumulated dose in all cases. The overall results show that the application of CD4007 as an electronic buffer in a radiation therapy system is limited by TID damage. However, this integrated circuit can be used as a cheap and sensitive radiation dosimeter for accumulated dose measurement in radiation therapy systems.

Keywords: threshold voltage shift, MOS transistor, linear extrapolation, gamma irradiation

Procedia PDF Downloads 256
15822 Coagulation-Flocculation of Palm Oil Mill Effluent from Pertubuhan Peladang Negeri Johor, Malaysia

Authors: A. H. Jagaba, Musa Babayo, Ab Aziz Abdul Latiff, Sule Abubakar, I. M. Lawal, Isa Zubairu, M. A. Nasara

Abstract:

Wastewater containing heavy metals is of extreme importance globally because of its potential threat to both the aquatic ecosystem and the soil environment. Heavy metal is hazardous even at low concentration and thereby causing various forms of diseases. One method which has been tested and found to be effective for heavy metals removal is coagulation-flocculation. For the coagulation process of POME obtained from Pertubuhan Peladang Negeri Johor (PPNJ), Oil Palm Mill Company located in Kahang area of Kluang, Johor Darul Takzim, Malaysia, diffèrent coagulants would be used to absorb and then separate the metals from wastewater. The determination of heavy metals concentration in POME was carried out using an inductively coupled plasma (ICP) and an Atomic Absorption Spectrometer (AAS). Results of the study showed that alum coagulant was successful in effectively reducing Cu, Cd, and Mn from 0.840 mg/l, 0.00509 mg/l and 8.191 mg/l to as low as 0.107 mg/l, 0.000270 mg/l and 0.612 mg/l respectively. All were obtained at a dose of 1000 mg/l. 1000 mg/l dose of ferric chloride reduced Pb concentration from 0.0248 mg/l to 0.00151 mg/l. Chitosan was best at reducing Fe and Zn from 62.91 mg/l and 3.616 mg/l to 6.003 mg/l and 0.595 mg/l all at a dose of 400 mg/l.

Keywords: palm oil mill effluent, coagulation, heavy metals, Pertubuhan Peladang Negeri Johor, Malaysia

Procedia PDF Downloads 200
15821 Protective Effect of Hesperidin against Cyclophosphamide Hepatotoxicity in Rats

Authors: Amr A. Fouad, Waleed H. Albuali, Iyad Jresat

Abstract:

The protective effect of hesperidin was investigated in rats exposed to liver injury induced by a single intraperitoneal injection of cyclophosphamide (CYP) at a dose of 150 mg kg-1. Hesperidin treatment (100 mg kg-1/day, orally) was applied for seven days, starting five days before CYP administration. Hesperidin significantly decreased the CYP-induced elevations of serum alanine aminotransferase, and hepatic malondialdehyde and myeloperoxidase activity, significantly prevented the depletion of hepatic glutathione peroxidase activity resulted from CYP administration. Also, hesperidin ameliorated the CYP-induced liver tissue injury observed by histopathological examination. In addition, hesperidin decreased the CYP-induced expression of inducible nitric oxide synthase, tumor necrosis factor-α, cyclooxygenase-2, Fas ligand, and caspase-9 in liver tissue. It was concluded that hesperidin may represent a potential candidate to protect against CYP-induced hepatotoxicity.

Keywords: hesperidin, cyclophosphamide, liver, rats

Procedia PDF Downloads 296
15820 A Study of The Factors Predicting Radiation Exposure to Contacts of Saudi Patients Treated With Low-Dose Radioactive Iodine (I-131)

Authors: Khalid A. Salman, Shereen Wagih, Tariq Munshi, Musaed Almalki, Safwan Zatari, Zahid Khan

Abstract:

Aim: To measure exposure levels to family members and caregivers of Saudi patients treated with low dose I131 therapy, and household radiation exposure rate to predict different factors that can affect radiation exposure. Patients and methods: All adult self dependent patients with hyperthyroidism or cancer thyroid referred for low dose radioactive I131 therapy on outpatient basis are included. Radiation protection procedures are given to the participant and family members in details. TLD’s were dispensed to each participant in sufficient quantity for his/her family members living in the household. TLD’s are collected at fifth days post-dispense from patients who agreed to have a home visit during which the household is inspected and level of radiation contamination of surfaces was measured. Results: Thirty-two patients were enrolled in the current study, with a mean age of 43.1± 17.1 years Out of them 25 patients (78%) are females. I131 therapy was given in twenty patients (63%) for cancer thyroid of and for toxic goiter in the remaining twelve patients (37%), with an overall mean I131 dose of 24.1 ± 7.5mCi that is relatively higher in the former. The overall number of household family members and helpers of patients are 139, out of them77 are females (55.4%) & 62 are males (44.6%) with a mean age of 29.8± 17.6. The mean period of contact with the patient is 7.6 ±5.6hours. The cumulative radiation exposure shows that radiation exposure to all family members is below the exposure constraint (1mSv), with a range of 109 to 503uSv, and a mean value of 220.9±91 uSv. Numerical data shows a little higher exposure rate for family members of those who receive higher dose of I131 (patients with thyroid cancer) and household members who spent longer time with the patient, yet, the difference is statistically insignificant (P>0.05). Besides, no significant correlation was found between the degree of cumulative exposure of the family members to their gender, age, socioeconomic standard, educational level and residential factors. In the 21 home visits all data from bedrooms, reception areas and kitchens are below hazardous limits (0.5uSv/h) apart from bathrooms that give a slightly higher reading of 0.57±0.39 uSv/h in those with cancer thyroid who receive a higher radiation dose. A statistically significant difference was found between radiation exposure rate in bathrooms used by the patient versus those used by family members only, with a mean value of exposure rate of 0.701±0.21 uSv/h and 0.17±0.82 uSv/h respectively, with a p-value of 0.018 (<0.05). Conclusion: Family members of patients treated with low dose I131 on outpatient basis have a good compliance to radiation protection instruction if given properly with a cumulative radiation exposure rate evidently beyond the radiation exposure constraints of 1 mSv. Given I131 dose, hours spent with the patient, age, gender, socioeconomic standard, educational level and residential factors have no significant correlation with the cumulative radiation exposure. The patient bathroom exhibits more radiation exposure rate, needing more strict instructions for patient bathroom use and health hygiene.

Keywords: family members, radiation exposure, radioactive iodine therapy, radiation safety

Procedia PDF Downloads 251
15819 Regression of Fibrosis by Apigenin in Thioacetamide-Induced Liver Fibrosis Rat Model through Suppression of HIF-1/FAK Pathway

Authors: Hany M. Fayed, Rehab F. Abdel-Rahman, Alyaa F. Hessin, Hanan A. Ogaly, Gihan F. Asaad, Abeer A. A. Salama, Sahar Abdelrahman, Mahmoud S. Arbid, Marwan Abd Elbaset Mohamed

Abstract:

Liver fibrosis is a serious global health problem that occurs as a result of a variety of chronic liver disorders. Apigenin, a flavonoid found in many plants, has several pharmacological properties. The aim of this study was to evaluate the antifibrotic efficacy of apigenin (APG) against experimentally induced hepatic fibrosis in rats via using thioacetamide (TAA) and to explore the possible underlying mechanisms. TAA (100 mg/kg, i.p.) was given three times each week for two weeks to induce liver fibrosis. After TAA injections, APG was given orally (5 and 10 mg/kg) daily for two weeks. Biochemical, molecular, histological and immunohistochemical analyses were performed on blood and liver tissue samples. The functioning of the liver, oxidative stress, inflammation, and liver fibrosis indicators were all evaluated. The findings showed that TAA markedly increased the activities of aspartate aminotransferase (AST) and alanine aminotransferase (ALT), as well as the levels of malondialdehyde (MDA), focal adhesion kinase (FAK), hypoxia-inducible factor-1 (HIF-1), nuclear factor-κB (NF-κB), transforming growth factor-beta (TGF-β), tumor necrosis factor-alpha (TNF-α) and interleukin-1β (IL-1β) with a reduction in albumin, total protein, A/G ratio, GSH content and interleukin-10 (IL-10). Moreover, TAA elevated the content of collagen I, α -smooth muscle actin (α-SMA), and hydroxyproline in the liver. The treatment with APG in a dose-dependent manner has obviously prevented these alterations and amended the harmful effects induced by TAA. The histopathological and immunohistochemical observations supported this biochemical evidence. The higher dose of APG produced the most significant antifibrotic effect. As a result of these data, APG appears to be a promising antifibrotic drug and could be used as a new herbal medication or dietary supplement in the future for the treatment of liver fibrosis. This effect might be related to the inhibition of the HIF-1/FAK signaling pathway.

Keywords: apigenin, FAK, HIF-1, liver fibrosis, rat, thioacetamide

Procedia PDF Downloads 100
15818 Evaluation of the Photo Neutron Contamination inside and outside of Treatment Room for High Energy Elekta Synergy® Linear Accelerator

Authors: Sharib Ahmed, Mansoor Rafi, Kamran Ali Awan, Faraz Khaskhali, Amir Maqbool, Altaf Hashmi

Abstract:

Medical linear accelerators (LINAC’s) used in radiotherapy treatments produce undesired neutrons when they are operated at energies above 8 MeV, both in electron and photon configuration. Neutrons are produced by high-energy photons and electrons through electronuclear (e, n) a photonuclear giant dipole resonance (GDR) reactions. These reactions occurs when incoming photon or electron incident through the various materials of target, flattening filter, collimators, and other shielding components in LINAC’s structure. These neutrons may reach directly to the patient, or they may interact with the surrounding materials until they become thermalized. A work has been set up to study the effect of different parameter on the production of neutron around the room by photonuclear reactions induced by photons above ~8 MeV. One of the commercial available neutron detector (Ludlum Model 42-31H Neutron Detector) is used for the detection of thermal and fast neutrons (0.025 eV to approximately 12 MeV) inside and outside of the treatment room. Measurements were performed for different field sizes at 100 cm source to surface distance (SSD) of detector, at different distances from the isocenter and at the place of primary and secondary walls. Other measurements were performed at door and treatment console for the potential radiation safety concerns of the therapists who must walk in and out of the room for the treatments. Exposures have taken place from Elekta Synergy® linear accelerators for two different energies (10 MV and 18 MV) for a given 200 MU’s and dose rate of 600 MU per minute. Results indicates that neutron doses at 100 cm SSD depend on accelerator characteristics means jaw settings as jaws are made of high atomic number material so provides significant interaction of photons to produce neutrons, while doses at the place of larger distance from isocenter are strongly influenced by the treatment room geometry and backscattering from the walls cause a greater doses as compare to dose at 100 cm distance from isocenter. In the treatment room the ambient dose equivalent due to photons produced during decay of activation nuclei varies from 4.22 mSv.h−1 to 13.2 mSv.h−1 (at isocenter),6.21 mSv.h−1 to 29.2 mSv.h−1 (primary wall) and 8.73 mSv.h−1 to 37.2 mSv.h−1 (secondary wall) for 10 and 18 MV respectively. The ambient dose equivalent for neutrons at door is 5 μSv.h−1 to 2 μSv.h−1 while at treatment console room it is 2 μSv.h−1 to 0 μSv.h−1 for 10 and 18 MV respectively which shows that a 2 m thick and 5m longer concrete maze provides sufficient shielding for neutron at door as well as at treatment console for 10 and 18 MV photons.

Keywords: equivalent doses, neutron contamination, neutron detector, photon energy

Procedia PDF Downloads 430
15817 Influence of Gamma-Radiation Dosimetric Characteristics on the Stability of the Persistent Organic Pollutants

Authors: Tatiana V. Melnikova, Lyudmila P. Polyakova, Alla A. Oudalova

Abstract:

As a result of environmental pollution, the production of agriculture and foodstuffs inevitably contain residual amounts of Persistent Organic Pollutants (POP). The special attention must be given to organic pollutants, including various organochlorinated pesticides (OCP). Among priorities, OCP is DDT (and its metabolite DDE), alfa-HCH, gamma-HCH (lindane). The control of these substances spends proceeding from requirements of sanitary norms and rules. During too time often is lost sight of that the primary product can pass technological processing (in particular irradiation treatment) as a result of which transformation of physicochemical forms of initial polluting substances is possible. The goal of the present work was to study the OCP radiation degradation at a various gamma-radiation dosimetric characteristics. The problems posed for goal achievement: to evaluate the content of the priority of OCPs in food; study the character the degradation of OCP in model solutions (with micro concentrations commensurate with the real content of their agricultural and food products) depending upon dosimetric characteristics of gamma-radiation. Qualitative and quantitative analysis of OCP in food and model solutions by gas chromatograph Varian 3400 (Varian, Inc. (USA)); chromatography-mass spectrometer Varian Saturn 4D (Varian, Inc. (USA)) was carried out. The solutions of DDT, DDE, alpha- and gamma- isomer HCH (0.01, 0.1, 1 ppm) were irradiated on "Issledovatel" (60Co) and "Luch - 1" (60Co) installations at a dose 10 kGy with a variation of dose rate from 0.0083 up to 2.33 kGy/sec. It was established experimentally that OCP residual concentration in individual samples of food products (fish, milk, cereal crops, meat, butter) are evaluated as 10-1-10-4 mg/kg, the value of which depends on the factor-sensations territory and natural migration processes. The results were used in the preparation of model solutions OCP. The dependence of a degradation extent of OCP from a dose rate gamma-irradiation has complex nature. According to our data at a dose 10 kGy, the degradation extent of OCP at first increase passes through a maximum (over the range 0.23 – 0.43 Gy/sec), and then decrease with the magnification of a dose rate. The character of the dependence of a degradation extent of OCP from a dose rate is kept for various OCP, in polar and nonpolar solvents and does not vary at the change of concentration of the initial substance. Also in work conditions of the maximal radiochemical yield of OCP which were observed at having been certain: influence of gamma radiation with a dose 10 kGy, in a range of doses rate 0.23 – 0.43 Gy/sec; concentration initial OCP 1 ppm; use of solvent - 2-propanol after preliminary removal of oxygen. Based on, that at studying model solutions of OCP has been established that the degradation extent of pesticides and qualitative structure of OCP radiolysis products depend on a dose rate, has been decided to continue researches radiochemical transformations OCP into foodstuffs at various of doses rate.

Keywords: degradation extent, dosimetric characteristics, gamma-radiation, organochlorinated pesticides, persistent organic pollutants

Procedia PDF Downloads 224
15816 Emblica officinalis Fruit Extract Ameliorates Cisplatin-Induced Nephrotoxicity in Experimental Rats

Authors: Prerna Kalra, Surender Singh

Abstract:

Cisplatin is the most common chemotherapeutic agent used in different solid tumors, but its main limiting factor is dose-dependent nephrotoxicity by generating reactive oxygen species, by stimulating inflammatory and apoptotic pathways. Additional adjuvant therapies to decrease the toxicity of this chemotherapeutic drug are essential. This study was designed to evaluate the protective role of Emblica officinalis Geartn (Indian gooseberry) against cisplatin induced nephrotoxicity. Emblica officinalis was orally administered to Wistar rats (n=6) for 10 days in 50, 100 and 200mg/kg body weight. On day 7, 8mg/kg of cisplatin was administered intra-peritoneally to rats in all groups. Serum creatinine, blood urea nitrogen and antioxidant levels were measured on day10. The renal damage was evaluated by histopathological and transmission electron microscopy. We found that 200mg/kg dose of Emblica officinalis significantly inhibited the elevation of biochemical parameters i.e. serum creatinine, blood urea nitrogen, oxidant stress marker (malondialdehyde) and increased the reduced levels of antioxidant marker (endogenous glutathione and superoxide dismutase). Cisplatin treated rats have shown acute tubular necrosis and infiltration of inflammatory cells in rat kidney which was reversed after treating the animals with Emblica officinalis in the treatment group. In ultrastructural changes cisplatin treated group showed the damaged mitochondria (M) with dissolved cristae and large number of lysosomes (L) and vacuole (V) formation in tubular epithelial cells. EOE administered group showed visible cristae formation and sign of autophagy vacuoles at a dose of 200mg/kg. Further in-silico studies revealed that ellagic acid is responsible for its nephroprotective effect. The above findings conclude that the Emblica officinalis may be used as an adjuvant therapy in cisplatin induced nephrotoxicity.

Keywords: antioxidant, cisplatin, Emblica officinalis, in silico, nephrotoxicity

Procedia PDF Downloads 263
15815 Reduction of the Risk of Secondary Cancer Induction Using VMAT for Head and Neck Cancer

Authors: Jalil ur Rehman, Ramesh C, Tailor, Isa Khan, Jahanzeeb Ashraf, Muhammad Afzal, Geofferry S. Ibbott

Abstract:

The purpose of this analysis is to estimate secondary cancer risks after VMAT compared to other modalities of head and neck radiotherapy (IMRT, 3DCRT). Computer tomography (CT) scans of Radiological Physics Center (RPC) head and neck phantom were acquired with CT scanner and exported via DICOM to the treatment planning system (TPS). Treatment planning was done using four arc (182-178 and 180-184, clockwise and anticlockwise) for volumetric modulated arc therapy (VMAT) , Nine fields (200, 240, 280, 320,0,40,80,120 and 160), which has been commonly used at MD Anderson Cancer Center Houston for intensity modulated radiation therapy (IMRT) and four fields for three dimensional radiation therapy (3DCRT) were used. True beam linear accelerator of 6MV photon energy was used for dose delivery, and dose calculation was done with CC convolution algorithm with prescription dose of 6.6 Gy. Primary Target Volume (PTV) coverage, mean and maximal doses, DVHs and volumes receiving more than 2 Gy and 3.8 Gy of OARs were calculated and compared. Absolute point dose and planar dose were measured with thermoluminescent dosimeters (TLDs) and GafChromic EBT2 film, respectively. Quality Assurance of VMAT and IMRT were performed by using ArcCHECK method with gamma index criteria of 3%/3mm dose difference to distance to agreement (DD/DTA). PTV coverage was found 90.80 %, 95.80 % and 95.82 % for 3DCRT, IMRT and VMAT respectively. VMAT delivered the lowest maximal doses to esophagus (2.3 Gy), brain (4.0 Gy) and thyroid (2.3 Gy) compared to all other studied techniques. In comparison, maximal doses for 3DCRT were found higher than VMAT for all studied OARs. Whereas, IMRT delivered maximal higher doses 26%, 5% and 26% for esophagus, normal brain and thyroid, respectively, compared to VMAT. It was noted that esophagus volume receiving more than 2 Gy was 3.6 % for VMAT, 23.6 % for IMRT and up to 100 % for 3DCRT. Good agreement was observed between measured doses and those calculated with TPS. The averages relative standard errors (RSE) of three deliveries within eight TLD capsule locations were, 0.9%, 0.8% and 0.6% for 3DCRT, IMRT and VMAT, respectively. The gamma analysis for all plans met the ±5%/3 mm criteria (over 90% passed) and results of QA were greater than 98%. The calculations for maximal doses and volumes of OARs suggest that the estimated risk of secondary cancer induction after VMAT is considerably lower than IMRT and 3DCRT.

Keywords: RPC, 3DCRT, IMRT, VMAT, EBT2 film, TLD

Procedia PDF Downloads 483