Search results for: blood loss
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 5581

Search results for: blood loss

5581 Tranexamic Acid in Prevention of Postpartum Haemorrhage in Elective Cesarean Section

Authors: Ajay Agrawal, Pravin Shah, Shailaja Chhetri, Pappu Rijal

Abstract:

Background and Objectives: Postpartum hemorrhage (PPH) is a common and occasionally life-threatening complication of labour. Cesarean section (CS) is associated with more blood loss than vaginal delivery. There is a trend for increasing CS rates in both developed and developing countries. This could increase the risk of morbidity and mortality, especially among anemic women. The objective of this study was to evaluate the effect of preoperative administration of Intravenous Tranexamic Acid (TA) on blood loss during and after elective CS delivery. Materials and Methods: It is a prospective, randomized controlled study. 160 eligible pregnant women of 37 or more POG planned for CS were randomized into two groups either to receive 10ml(1gm) of tranexamic acid intravenously or 10ml of normal saline. Blood loss was measured during and for 24 hours after operation. Results: The mean estimated blood loss was significantly lower in women treated with TA compared with women in the placebo group (392.13 ml ± 10.06 versus 498.69 ml ± 15.87, respectively; p < 0.001). The mean difference in pre-operative and post-operative hemoglobin levels was statistically significant in the tranexamic acid group than in the control group (0.31 ± 0.18 versus 0.79 ± 0.23, respectively; p < 0.001). Conclusion: Pre-operative use of tranexamic acid is associated with reduced blood loss during and after elective cesarean section. In a developing country like ours where PPH is a major threat to the life of the mothers, it seems to be a promising option.

Keywords: blood loss, cesarean section, postpartum hemorrhage, tranexamic acid

Procedia PDF Downloads 248
5580 Myomectomy and Blood Loss: A Quality Improvement Project

Authors: Ena Arora, Rong Fan, Aleksandr Fuks, Kolawole Felix Akinnawonu

Abstract:

Introduction: Leiomyomas are benign tumors that are derived from the overgrowth of uterine smooth muscle cells. Women with symptomatic leiomyomas who desire future fertility, myomectomy should be the standard surgical treatment. Perioperative hemorrhage is a common complication in myomectomy. We performed the study to investigate blood transfusion rate in abdominal myomectomies, risk factors influencing blood loss and modalities to improve perioperative blood loss. Methods: Retrospective chart review was done for patients who underwent myomectomy from 2016 to 2022 at Queens hospital center, New York. We looked at preoperative patient demographics, clinical characteristics, intraoperative variables, and postoperative outcomes. Mann-Whitney U test were used for parametric and non-parametric continuous variable comparisons, respectively. Results: A total of 159 myomectomies were performed between 2016 and 2022, including 1 laparoscopic, 65 vaginal and 93 abdominal. 44 patients received blood transfusion during or within 72 hours of abdominal myomectomy. The blood transfusion rate was 47.3%. Blood transfusion rate was found to be twice higher than the average documented rate in literature which is 20%. Risk factors identified were black race, preoperative hematocrit<30%, preoperative blood transfusion within 72 hours, large fibroid burden, prolonged surgical time, and abdominal approach. Conclusion: Preoperative optimization with iron supplements or GnRH agonists is important for patients undergoing myomectomy. Interventions to decrease intra operative blood loss should include cell saver, tourniquet, vasopressin, misoprostol, tranexamic acid and gelatin-thrombin matrix hemostatic sealant.

Keywords: myomectomy, perioperative blood loss, cell saver, tranexamic acid

Procedia PDF Downloads 55
5579 An AFM Approach of RBC Micro and Nanoscale Topographic Features During Storage

Authors: K. Santacruz-Gomez, E. Silva-Campa, S. Álvarez-García, V. Mata-Haro, D. Soto-Puebla, M. Pedroza-Montero

Abstract:

Blood gamma irradiation is the only available method to prevent transfusion-associated graft versus host disease (TA-GVHD). However, when blood is irradiated, determine blood shelf time is crucial. Non-irradiated blood has a self-time from 21 to 35 days when is preserved with an anticoagulated solution and stored at 4°C. During their storage, red blood cells (RBC) undergo a series of biochemical, biomechanical and molecular changes involving what is known as storage lesion (SL). SL include loss of structural integrity of RBC, a decrease of 2,3-diphosphatidylglyceric acid levels, and an increase of both ion potassium concentration and hemoglobin (Hb). On the other hand, Atomic force Microscopy (AFM) represents a versatile tool for a nano-scale high-resolution topographic analysis in biological systems. In order to evaluate SL in irradiated and non-irradiated blood, RBC topography and morphometric parameters were obtained from an AFM XE-BIO system. Cell viability was followed using flow cytometry. Our results showed that early markers as nanoscale roughness, allow us to evaluate blood quality since another perspective.

Keywords: AFM, blood γ-irradiation, roughness, storage lesion

Procedia PDF Downloads 506
5578 EhfadHaya (SaveLife) / AateHayah (GiveLife) Blood Donor Website

Authors: Sameer Muhammad Aslam, Nura Said Mohsin Al-Saifi

Abstract:

This research shows the process of creating a blood donation website for Oman. Blood donation is a widespread, crucial, ongoing process, so it is important that this website is easy to use. Several automated blood management systems are available, but none provides an effective algorithm that takes into account variables such as frequency of donation, donation date, and gender. In Oman, the Ministry of Health maintains a blood bank and keeps donors informed about the need for blood through a website. They also inform donors and the wider public where and when is their next blood donation event. The website's main goals are to educate the community about the benefits of blood donation. It also manages donor and receiver documentation and encourages voluntary blood donation by providing easy access to information about blood types and blood distribution in various hospitals in Oman, based on hospital needs.

Keywords: Oman, blood bank, blood donors, donor website

Procedia PDF Downloads 183
5577 Signal Processing of the Blood Pressure and Characterization

Authors: Hadj Abd El Kader Benghenia, Fethi Bereksi Reguig

Abstract:

In clinical medicine, blood pressure, raised blood hemodynamic monitoring is rich pathophysiological information of cardiovascular system, of course described through factors such as: blood volume, arterial compliance and peripheral resistance. In this work, we are interested in analyzing these signals to propose a detection algorithm to delineate the different sequences and especially systolic blood pressure (SBP), diastolic blood pressure (DBP), and the wave and dicrotic to do their analysis in order to extract the cardiovascular parameters.

Keywords: blood pressure, SBP, DBP, detection algorithm

Procedia PDF Downloads 409
5576 Efficacy Of Tranexamic Acid On Blood Loss After Primary Total Hip Replacement : A Case-control Study In 154 Patients

Authors: Fedili Benamar, Belloulou Mohamed Lamine, Ouahes Hassane, Ghattas Samir

Abstract:

Introduction: Perioperative blood loss is a frequent cause of complications in total hip replacement (THR). The present prospective study assessed the efficacy of tranexamic acid (Exacyl(®)) in reducing blood loss in primary THR. Hypothesis: Tranexamic acid reduces blood loss in THR. Material and method: -This is a prospective randomized study on the effectiveness of Exacyl (tranexamic acid) in total hip replacement surgery performed on a standardized technique between 2019 and September 2022. -It involved 154 patients, of which 84 received a single injection of Exacyl (group 1) at a dosage of 10 mg/kg over 20 minutes during the perioperative period. -All patients received postoperative thromboprophylaxis with enoxaparin 0.4 ml subcutaneously. -All patients were admitted to the post-interventional intensive care unit for a duration of 24 hours for monitoring and pain management as per the service protocol. Results: 154 patients, of which 84 received a single injection of Exacyl (group 1) and 70 patients patients who did not receive Exacyl perioperatively : (Group 2 ) The average age is 57 +/- 15 years The distribution by gender was nearly equal with 56% male and 44% female; "The distribution according to the ASA score was as follows: 20.2% ASA1, 82.3% ASA2, and 17.5% ASA3. "There was a significant difference in the average volume of intraoperative and postoperative bleeding during the 48 hours." The average bleeding volume for group 1 (received Exacyl) was 614 ml +/- 228, while the average bleeding volume for group 2 was 729 +/- 300, with a chi-square test of 6.35 and a p-value < 0.01, which is highly significant. The ANOVA test showed an F-statistic of 7.11 and a p-value of 0.008. A Bartlett test revealed a chi-square of 6.35 and a p-value < 0.01." "In Group 1 (patients who received Exacyl), 73% had bleeding less than 750 ml (Group A), and 26% had bleeding exceeding 750 ml (Group B). In Group 2 (patients who did not receive Exacyl perioperatively), 52% had bleeding less than 750 ml (Group A), and 47% had bleeding exceeding 750 ml (Group B). "Thus, the use of Exacyl reduced perioperative bleeding and specifically decreased the risk of severe bleeding exceeding 750 ml by 43% with a relative risk (RR) of 1.37 and a p-value < 0.01. The transfusion rate was 1.19% in the population of Group 1 (Exacyl), whereas it was 10% in the population of Group 2 (no Exacyl). It can be stated that the use of Exacyl resulted in a reduction in perioperative blood transfusion with an RR of 0.1 and a p-value of 0.02. Conclusions: The use of Exacyl significantly reduced perioperative bleeding in this type of surgery.

Keywords: acid tranexamic, blood loss, anesthesia, total hip replacement, surgery

Procedia PDF Downloads 44
5575 Simulation of Remove the Fouling on the in vivo By Using MHD

Authors: Farhad Aalizadeh, Ali Moosavi

Abstract:

When a blood vessel is injured, the cells of your blood bond together to form a blood clot. The blood clot helps you stop bleeding. Blood clots are made of a combination of blood cells, platelets(small sticky cells that speed up the clot-making process), and fibrin (protein that forms a thread-like mesh to trap cells). Doctors call this kind of blood clot a “thrombus.”We study the effects of different parameters on the deposition of Nanoparticles on the surface of a bump in the blood vessels by the magnetic field. The Maxwell and the flow equations are solved for this purpose. It is assumed that the blood is non-Newtonian and the number of particles has been considered enough to rely on the results statistically. Using MHD and its property it is possible to control the flow velocity, remove the fouling on the walls and return the system to its original form.

Keywords: MHD, fouling, in-vivo, blood clots, simulation

Procedia PDF Downloads 441
5574 Improving the Design of Blood Pressure and Blood Saturation Monitors

Authors: L. Parisi

Abstract:

A blood pressure monitor or sphygmomanometer can be either manual or automatic, employing respectively either the auscultatory method or the oscillometric method. The manual version of the sphygmomanometer involves an inflatable cuff with a stethoscope adopted to detect the sounds generated by the arterial walls to measure blood pressure in an artery. An automatic sphygmomanometer can be effectively used to monitor blood pressure through a pressure sensor, which detects vibrations provoked by oscillations of the arterial walls. The pressure sensor implemented in this device improves the accuracy of the measurements taken.

Keywords: blood pressure, blood saturation, sensors, actuators, design improvement

Procedia PDF Downloads 429
5573 A Comparison of Three Protocols Weight-Loss Interventions for Obese Females

Authors: Nayera E. Hassan, Sahar A. El-Masry, Rokia El-Banna, Mohamed S. El Hussieny

Abstract:

There are several different modalities for treatment of obesity. Common intervention methods for obesity include low-calorie diet, exercise. Also acupuncture has shown good therapeutic results in the treatment of obesity. A recent clinical observation showed that laser acupuncture could reduce body weight and body mass index in obese persons. So, the aim of this research is focused on body composition changes as related to type of intervention, before and after intentional weight loss in overweight and obesity. 76 subjects were included in the study analysis. The present study recommended that every obese female must do lipid profile and fasting blood sugar analysis before weight-loss intervention to take the decision of which method should be used.

Keywords: obesity, weight-loss, body composition, modalities

Procedia PDF Downloads 454
5572 Tranexamic Acid in Orthopedic Surgery in Children

Authors: K. Amanzoui, A. Erragh, M. Elharit, A. Afif, K. Elfakhr, S. Kalouch, A. Chlilek

Abstract:

Orthopedic surgery is a provider of pre and postoperative bleeding; patients are exposed to several risks, and different measures are proposed to reduce bleeding during surgery, called the transfusion-sparing method, including tranexamic acid, which has shown its effectiveness in numerous studies. A prospective analytical study in 50 children was carried out in the orthopedic traumatology operating room of the EL HAROUCHI hospital of the CHU IBN ROCHD in Casablanca over a period of six months (April to October 2022). Two groups were randomized: one receiving tranexamic acid (Group A) and a non-receiving control group (Group B). The average age was 10.3 years, of which 58.8% were female. The first type of surgery was thoracolumbar scoliosis (52%). The average preoperative hemoglobin was 12.28 g/dl in group A, against 12.67 g/dl in the control group. There was no significant difference between the two groups (p=0.148). Mean intraoperative bleeding was 396.29 ml in group A versus 412 ml in the control group. No significant difference was observed for this parameter (p=0.632). The average hemoglobin level in the immediate postoperative period in our patients is 10.2 g/dl. In group A, it was 10.95 g/dl versus 10.93 g/dl in group B. At H24 postoperative, the mean hemoglobin value was 10.29 g/dl in group A against 9.5 g/dl in group B. For group A, the blood loss recorded during the first 24 hours was 209.43 ml, against 372 ml in group B, with a significant difference between the two groups (p=0.001). There is no statistically significant difference between the 2 groups in terms of the use of fillers, ephedrine or intraoperative transfusion. While for postoperative transfusion, we note the existence of a statistically significant difference between group A and group B. It is suggested that the use of tranexamic acid is an effective, simple, and low-cost way to limit postoperative blood loss and the need for transfusion.

Keywords: tranexamic acid, blood loss, orthopedic surgery, children

Procedia PDF Downloads 46
5571 A New Manoeuvre for Prevention of Post-Partum Haemorrhage

Authors: Amr Hamdy

Abstract:

Background: Postpartum haemorrhage (PPH) is the leading cause of maternal mortality worldwide. Many methods have been developed to decrease its rate. The aim of this study was to evaluate the applicability of a new non-pharmacologic maneuver in decreasing its rate. Methods: This case series study was conducted in one centre in Cairo, Egypt, from January-2010 to June-2013. 400 pregnant–women aged 18 years or more and candidate for normal labour; were enrolled to this study. High-risk subjects for PPH were excluded. After placental delivery, the new maneuver was done by sustained traction of the anterior and posterior lips of the cervix by two ovum forceps for duration of 90 seconds. The amount of blood loss was estimated by standardized visual estimation after removal of the forceps. All subjects were followed up for 6 hours. Results: The rate of PPH, defined as more than 500 ml, was 8 cases (2%) with 95% CI (0.63-3.37%). The rate of PPH was not affected by parity, gestational age, episiotomy or the presence of tears. PPH is more in cases with anemia (p 0.032). It occurred in all cases with uterine atony (p <0.001). The range of estimated blood loss was 550-600ml in cases with PPH and 150-450ml in cases without PPH. Severe PPH more than 1000 ml, did not occur. Conclusion: This pilot study introduced a novel maneuver that can be helpful in decreasing the rate of PPH and reducing the amount of post partum blood loss.Despite the low rate of PPH showed in this study, the need for conducting a randomized controlled study is at its highest level before further inclusion of such manoeuvre to be a part of the current medical practice and before considering it as an evident tool to decrease the burden of PPH.

Keywords: maternal mortality, new manoeuvre, post-partum haemorrhage, uterine atony

Procedia PDF Downloads 169
5570 The Amount of Organic Phosphates (Like DPG) Existing in Blood is Determining Factor of Mammal’s Bulk

Authors: Ramin Amirmardfar

Abstract:

Throughout Necessary oxygen should be supplied for all cells of a mammal at any moment through blood to make it possible remain alive all cells the mammal’s body. In case a mammal’s bulk is large, there is a farther distance between cells in different tissues and mammals’ heart. Therefore red blood cells in bulky mammal’s body should be capable of conveying oxygen to farther distances. To make it practical, oxygen should be glued red blood cells tenaciously. In other words, cohesion strength of oxygen to red blood cell of bulky mammal’s blood should be much more than the same of small mammal’s blood. In mammal’s bodies, the controlling factor of amount of cohesion of oxygen to red blood cell, are organic phosphates (like DPG). The less DPG in red blood cells of a mammal, the more cohesion of oxygen to red blood cell (at the same rate). As much as oxygen is glued more tenacious to red blood cells, oxygen could been carried to farther distance and as much as oxygen could be conveyed to farther points of heart, bulk of mammal could be larger at the same rate.

Keywords: mammals size, animals size, organic phosphates, DPG, red blood cell, metabolism

Procedia PDF Downloads 327
5569 Evaluation of the Safety and Performance of Blood Culture Practices Using BD Safety-Lokᵀᴹ Blood Collection Sets in the Emergency Room

Authors: Jeonghyun Chang, Taegeun Lee, Heungsup Sung, Yoon-Seon Lee, Youn-Jung Kim, Mi-Na Kim

Abstract:

Background: Safety device has been applied to improve safety and performance of blood culture practice. BD vacutainer® Safety-Lokᵀᴹ blood collection sets with pre-attached holder (Safety-Lok) (BD, USA) was evaluated in the emergency room (ER) of a tertiary care hospital. Methods: From April to June 2017, interns and nurses in ER were surveyed for blood culture practices with a questionnaire before and after 2 or 3 weeks of experience of Safety-Lok. All of them participated in exercise workshop for 1 hour combined with video education prior to the initial survey. The blood volume, positive and contamination rates of Safety-Lok-drawn (SD) blood cultures were compared to those of overall blood cultures. Results: Eighteen interns and 30 nurses were enrolled. As a result of the initial survey, interns had higher rates of needlestick incidence (27.8%), carriage of the blood-filled syringe with needle (88.9%) and lower rates of vacutainer use (38.9%) than nurses (13.3%, 53.3%, and 60.0%). Interns preferred to use safety devices (88.9%) rather than nurses (40.0%). The number of overall blood cultures and SD blood cultures was 9,053 and 555, respectively. While the overall blood volume of aerobic bottles was 2.6±2.1 mL, those of SD blood cultures were 5.0±3.0 mL in aerobic bottles and 6.0±3.0 mL in anaerobic bottles. Positive and contamination rates were 6.5% and 0.72% with SD blood cultures and 6.2% and 0.3% with overall blood cultures. Conclusions: The introduction of the safety device would encourage healthcare workers to collect adequate blood volume as well as lead to safer practices in the ER.

Keywords: blood culture, needlestick, safety device, volume

Procedia PDF Downloads 176
5568 Microfluidic Method for Measuring Blood Viscosity

Authors: Eunseop Yeom

Abstract:

Many cardiovascular diseases, such as thrombosis and atherosclerosis, can change biochemical molecules in plasma and red blood cell. These alterations lead to excessive increase of blood viscosity contributing to peripheral vascular diseases. In this study, a simple microfluidic-based method is used to measure blood viscosity. Microfluidic device is composed of two parallel side channels and a bridge channel. To estimate blood viscosity, blood samples and reference fluid are separately delivered into each inlet of two parallel side channels using pumps. An interfacial line between blood samples and reference fluid occurs by blocking the outlet of one side-channel. Since width for this interfacial line is determined by pressure ratio between blood and reference flows, blood viscosity can be estimated by measuring width for this interfacial line. This microfluidic-based method can be used for evaluating variations in the viscosity of animal models with cardiovascular diseases under flow conditions.

Keywords: blood viscosity, microfluidic chip, pressure, shear rate

Procedia PDF Downloads 340
5567 Direct Cost of Anesthesia in Traumatic Patients with Massive Bleeding: A Prospective Micro-Costing Study

Authors: Asamaporn Puetpaiboon, Sunisa Chatmongkolchart, Nalinee Kovitwanawong, Osaree Akaraborworn

Abstract:

Traumatic patients with massive bleeding require intensive resuscitation. The actual cost of anesthesia per case has never been clarified, so our study aimed to quantify the direct cost, and cost-to-charge ratio of anesthetic care in traumatic patients with intraoperative massive bleeding. This study was a prospective, observational, cost analysis study, conducted in Prince of Songkla University hospital, Thailand, with traumatic patients, of any mechanisms being recruited. Massive bleeding was defined as estimated blood loss of at least one blood volume in 24 hours, or a half of blood volume in 3 hours. The cost components were identified by the micro-costing method, and valued by the bottom-up approach. The direct cost was divided into 4 categories: the labor cost, the capital cost, the material cost and the cost of drugs. From September 2017 to August 2018, 10 patients with multiple injuries were included. Seven patients had motorcycle accidents, two patients fell from a height and another one was in a minibus accident. Two patients died on the operating table, and another two died within 48 hours. The median Sequential Organ Failure Assessment (SOFA) score was 8. The median intraoperative blood loss was 3,500 ml. The median direct cost, per case, was 250 United States Dollars (2017 exchange rate), and the cost-to-charge ratio was 0.53. In summary, the direct cost was nearly half of the hospital charge, for these traumatic patients with massive bleeding. However, our study did not analyze the indirect cost.

Keywords: cost, cost-to-charge ratio, micro-costing, trauma

Procedia PDF Downloads 119
5566 Effect of Hypertension Exercise and Slow Deep Breathing Combination to Blood Pressure: A Mini Research in Elderly Community

Authors: Prima Khairunisa, Febriana Tri Kusumawati, Endah Luthfiana

Abstract:

Background: Hypertension in elderly, caused by cardiovascular system cannot work normally, because the valves thickened and inelastic blood vessels. It causes vasoconstriction of the blood vessels. Hypertension exercise, increase cardiovascular function and the elasticity of the blood vessels. While slow deep breathing helps the body and mind feel relax. Combination both of them will decrease the blood pressure. Objective: To know the effect of hypertension exercise and slow deep breathing combination to blood pressure in elderly. Method: The study conducted with one group pre-post test experimental design. The samples were 10 elderly both male and female in a Village in Semarang, Central Java, Indonesia. The tool was manual sphygmomanometer to measure blood pressure. Result: Based on paired t-test between hypertension exercise and slow deep breathing with systole blood pressure showed sig (2-tailed) was 0.045, while paired t-test between hypertension exercise hypertension exercise and slow deep breathing with diastole blood pressure showed sig (2-tailed) was 0,343. The changes of systole blood pressure were 127.5 mmHg, and diastole blood pressure was 80 mmHg. Systole blood pressure decreases significantly because the average of systole blood pressure before implementation was 135-160 mmHg. While diastole blood pressure was not decreased significantly. It was influenced by the average of diastole blood pressure before implementation of hypertension exercise was not too high. It was between 80- 90 mmHg. Conclusion: There was an effect of hypertension exercise and slow deep breathing combination to the blood pressure in elderly after 6 times implementations.

Keywords: hypertension exercise, slow deep breathing, elderly, blood pressure

Procedia PDF Downloads 315
5565 Blood Clot Emulsification via Ultrasonic Thrombolysis Device

Authors: Sun Tao, Lou Liang, Tan Xing Haw Marvin, Gu Yuandong Alex

Abstract:

Patients with blood clots in their brains can experience problems with their vision or speech, seizures and general weakness. To treat blood clots, clinicians presently have two options. The first involves drug therapy to thin the blood and thus reduce the clot. The second choice is to invasively remove the clot using a plastic tube called a catheter. Both approaches carry a high risk of bleeding, and invasive procedures, such as catheter intervention, can also damage the blood vessel wall and cause infection. Ultrasonic treatment as a potential alternative therapy to break down clots is attracting growing interests due to the reduced adverse effects. To demonstrate the concept, in this investigation a microfabricated ultrasonic device was electrically packaged with printed circuit board to treat healthy human blood. The red blood cells could be broken down after 3-hour ultrasonic treatment.

Keywords: microfabrication, blood clot, ultrasonic thrombolysis device, ultrasonic device

Procedia PDF Downloads 421
5564 Prevalence and Patterns of Hearing Loss among the Elderly with Hypertension in Southwest, Nigeria

Authors: Ayo Osisanya, Promise Ebuka Okonkwo

Abstract:

Reduced hearing sensitivity among the elderly has been attributed to some risk factors and influence of age-related degenerative conditions such as diabetes, cardiovascular disease, Alzheimer’s disease, bipolar disorder, and hypertension. Hearing loss; especially the age-related type (presbycusis), has been reported as one of the global burden affecting the general well-being and quality of life of the elderly with hypertension. Thus, hearing loss has been observed to be associated with hypertension and functional decline in elderly, as this condition makes them experience poor communication, fatigue, reduced social functions, mood-swing, and withdrawal syndrome. Emerging research outcomes indicate a strong relationship between hypertension and reduced auditory performance among the elderly. Therefore, this study determined the prevalence, types, and patterns of hearing loss associated with hypertension, with a bid to suggesting comprehensive management strategies and a model of creating awareness towards promoting good healthy living among the elderly in Nigeria. One hundred and seventy-two elderly, aged 65–85 with hypertension were purposively selected from patients undergoing treatment for hypertension in some tertiary hospitals in southwest Nigeria for the study. Participants were suggested to Pure-Tone Audiometry (PTA) through the use of Maico 53 Diagnostic Audiometer to determine the degree, types ad patterns of hearing loss among the elderly with hypertension. Results showed that 148 (86.05%) elderly with hypertension presented with different degrees, types, and patterns of hearing loss. Out of this number, 123 (83.11%) presented with bilateral hearing loss, while 25 (16.89%) had unilateral hearing loss. Degree of hearing loss, 74 moderate hearing loss, 118 moderately severe and 50 severe hearing loss. 36% of the hearing loss appeared as flat audiometric configuration, 24% were slopping, 19% were rising, while 21% were tough-shaped audiometric configurations. The findings showed high prevalence of hearing loss among the elderly with hypertension in Southwest, Nigeria. Based on the findings, management of elderly with hypertension should include regular audiological rehabilitation and total adherence to hearing conservation principles, otological management, regulation of blood pressure and adequate counselling / follow-up services.

Keywords: auditory performance, elderly, hearing loss, hypertension

Procedia PDF Downloads 269
5563 Therapeutic Efficacy and Safety Profile of Tolvaptan Administered in Hyponatremia Patients

Authors: Sree Vennela P., V. Samyuktha Bhardwaj

Abstract:

Hyponatremia is an electrolyte disturbance in which the sodium ion concentration in the serum is lower than normal. Sodium is the dominant extracellular cation (positive ion) and cannot freely cross from the interstitial space through the cell membrane, into the cell. Its homeostasis (stability of concentration) inside the cell is vital to the normal function of any cell. Normal serum sodium levels are between 135 and 145 mEq/L. Hyponatremia is defined as a serum level of less than 135 mEq/L and is considered severe when the serum level is below 125 mEq/L. In the vast majority of cases, Hyponatremia occurs as a result of excess body water diluting the serum sodium (salt level in the blood). Hyponatremia is often a complication of other medical illnesses in which excess water accumulates in the body at a higher rate than can be excreted (for example in congestive heart failure, syndrome of inappropriate antidiuretic hormone, SIADH, or polydipsia). Sometimes it may be a result of over-hydration (drinking too much water).Lack of sodium (salt) is very rarely the cause of Hyponatremia, although it can promote Hyponatremia indirectly. In particular, sodium loss can lead to a state of volume depletion (loss of blood volume in the body), with volume depletion serving as a signal for the release of ADH (anti-diuretic hormone). As a result of ADH-stimulated water retention (too much water in the body), blood sodium becomes diluted and Hyponatremia results.

Keywords: Tolvaptan, hyponatremia, syndrome of insufficient anti diuretic hormone (SIADH), euvolemic hyponatremia

Procedia PDF Downloads 238
5562 The Prevalence of X-Chromosome Aneuploidy in Recurrent Pregnancy Loss

Authors: Rim Frikha, Nouha Bouayed, Afifa Sellami, Nozha Chakroun, Salima Douad, Leila Keskes, Tarek Rebai

Abstract:

Recurrent pregnancy loss (RPL), classically defined as the occurrence of two or more failed pregnancies, is a serious reproductive problem, in which, chromosomal rearrangements in either carrier are a major cause; mainly the chromosome aneuploidy. This study was conducted to determine the frequency and contribution of X-chromosome aneuploidy in recurrent pregnancy loss. A retrospective study was carried out among 100 couples with more than 2 miscarriages, referred to our genetic counseling. In all the cases the detailed reproductive histories were taken. Chromosomal analysis was performed using RHG banding in peripheral blood. Of a total of 100 couples; 3 patients with a detected X-chromosome aneuploidy were identified with an overall frequency of 3%. Chromosome abnormalities are as below: a Turner syndrome with 45, X/46, XX mosaicism, a 47, XXX, and a Klinefelter syndrome with 46, XY/47, XXY. These data show a high incidence of X-chromosome aneuploidy; mainly with mosaicism; in RPL. Thus, couples with such chromosomal abnormality should be referred to a clinical geneticist with whom the option of pre-implantation genetic diagnosis in subsequent pregnancy should be discussed.

Keywords: aneuploidy, genetic testing, recurrent pregnancy loss, X-chromosome

Procedia PDF Downloads 337
5561 Development of Monitoring Blood Bank Center Based PIC Microcontroller Using CAN Communication

Authors: Kaiwan S. Ismael, Ergun Ercelebi, Majeed Nader

Abstract:

This paper describes the design and implementation of a hardware setup for online monitoring of 24 refrigerators inside blood bank center using the microcontroller and CAN bus for communications between each node. Due to the security of locations in the blood bank hall and difficulty of monitoring of each refrigerator separately, this work proposes a solution to monitor all the blood bank refrigerators in one location. CAN-bus system is used because it has many applications and advantages, especially for this system due to easy in use, low cost, providing a reduction in wiring, fast to repair and easily expanding the project without a problem.

Keywords: control area network (CAN), monitoring blood bank center, PIC microcontroller, MPLAB IDE

Procedia PDF Downloads 444
5560 Lead in The Blood and Hypertension in Indonesia: A Systematic Review

Authors: Ainia Nurul Aqida

Abstract:

Lead is one of the sources of air pollution. The use of lead on motor vehicle fuels resulted in the increasing contamination of lead in the air. The polluted air that has been inhaled by many people, especially guards and sellers of retail gasoline filling stations. The impact is increased levels of lead in blood. One result is an increase in blood pressure that causes hypertension. This research would like to know the relationship between blood lead levels in the incidence of hypertension in Indonesia. The method used in this study is a systematic review of the three journals have been published in the year 2007 to the year 2010 with the total sample is 312 samples. Odd ratio values obtained in the first article was OR = 6.50 pvalue = 0.000, CI = 95 % (2.89 to 14.60), and the second article was obtained OR 2.619 (95 % CI: 0.944 to 7.625) pvalue = 0.028, and the third article was obtained 0.002 r = 0.324 R2 = 10.5 %. Over all, there is a relationship between blood lead levels with the incidence of hypertension in Indonesia.

Keywords: lead, blood, air pollution, hypertension

Procedia PDF Downloads 298
5559 Monitoring Blood Pressure Using Regression Techniques

Authors: Qasem Qananwah, Ahmad Dagamseh, Hiam AlQuran, Khalid Shaker Ibrahim

Abstract:

Blood pressure helps the physicians greatly to have a deep insight into the cardiovascular system. The determination of individual blood pressure is a standard clinical procedure considered for cardiovascular system problems. The conventional techniques to measure blood pressure (e.g. cuff method) allows a limited number of readings for a certain period (e.g. every 5-10 minutes). Additionally, these systems cause turbulence to blood flow; impeding continuous blood pressure monitoring, especially in emergency cases or critically ill persons. In this paper, the most important statistical features in the photoplethysmogram (PPG) signals were extracted to estimate the blood pressure noninvasively. PPG signals from more than 40 subjects were measured and analyzed and 12 features were extracted. The features were fed to principal component analysis (PCA) to find the most important independent features that have the highest correlation with blood pressure. The results show that the stiffness index means and standard deviation for the beat-to-beat heart rate were the most important features. A model representing both features for Systolic Blood Pressure (SBP) and Diastolic Blood Pressure (DBP) was obtained using a statistical regression technique. Surface fitting is used to best fit the series of data and the results show that the error value in estimating the SBP is 4.95% and in estimating the DBP is 3.99%.

Keywords: blood pressure, noninvasive optical system, principal component analysis, PCA, continuous monitoring

Procedia PDF Downloads 132
5558 Improvement of Vascular Oxidative Stress in Diabetic Rats by Supplementation with a Wine Pomace Product

Authors: P. Muñiz, R. Del Pino-García , M.D. Rivero-Pérez, J. García-Lomillo, M. L. González-SanJosé

Abstract:

Grape, wine and wine pomace could improve the antioxidant status in the vasculature in terms of plasma antioxidant capacity and oxidation biomarkers, partly due to their high content in polyphenols. The current study aimed to evaluate the protection of a powdered product obtained from wine pomace (WPP) against oxidative damage associated to diabetes. Streptozotocin-induced diabetic (STZ) male Wistar rats and non-diabetic control (C) rats initially weighting 300±10 mg were supplemented with 100 mg of WPP or vehicle for 4 weeks. Blood glucose levels and body weight (BW) were measured weekly. Total antioxidant capacity (TAC) assessed using the ABTS method, and F2α-Isoprostanes (F2-IsoPs) quantified by GC-MS were measured in plasma collected at the end of this experiment. Blood glucose levels tended to increase in the STZ group along the study. Supplementation maintained relatively stable during the whole experiment the blood glucose values in STZ+WPP rats. A weight loss of BW in STZ rats respect to C rats was observed after 4 weeks, whereas the decrease in BW of STZ+WPP group showed a tendency to improve at the end of the study. TAC values significantly decreased around 11% only in plasma of STZ rats. The rest of groups showed plasma TAC values about 8 mM Trolox. Increased levels of F2-IsoPs (around 25%) were also observed in plasma of STZ rats compared to the supplemented rats, revealing a protective effect of WPP against lipid peroxidation. In conclusion, 4-week supplementation with a product derived from winery by-products improved weight loss, plasma TAC, and lipid oxidation biomarkers in Type I diabetic rats.

Keywords: blood glucose, grape polyphenols, F2α-isoprostanes, type I diabetes, oxidative stress

Procedia PDF Downloads 446
5557 Evaluation of Different Anticoagulant Effects on Flow Properties of Human Blood Using Falling Needle Rheometer

Authors: Hiroki Tsuneda, Takamasa Suzuki, Hideki Yamamoto, Kimito Kawamura, Eiji Tamura, Katharina Wochner, Roberto Plasenzotti

Abstract:

Flow property of human blood is one of the important factors on the prevention of the circulatory condition such as a high blood pressure, a diabetes mellitus, and a cardiac infarction. However, the measurement of flow property of human blood, especially blood viscosity, is not so easy, because of their coagulation or aggregation behaviors after taking a sample from blood vessel. In the experiment, some kinds of anticoagulant were added into the human blood to avoid its solidification. Anticoagulant used in the blood test has been chosen for each purpose of blood test, for anticoagulant effect on blood is different mechanism for each. So that, there is a problem that the evaluation of measured blood property with different anticoagulant is so difficult. Therefore, it is so important to make clear the difference of anticoagulant effect on the blood property. In the previous work, a compact-size falling needle rheometer (FNR) has been developed in order to measure the flow property of human blood such as a flow curve, an apparent viscosity. It was found that FNR system can apply to a rheometer or a viscometry for various experimental conditions for not only human blood but also mammalians blood. In this study, the measurements of human blood viscosity with different anticoagulant (EDTA and Heparin) were carried out using newly developed FNR system. The effect of anticoagulant on blood viscosity was also tested by using the standard liquid for each. The accuracy on the viscometry was also tested by using the standard liquid for calibrating materials (JS-10, JS-20) and observed data have satisfactory agreement with reference data around 1.0% at 310K. The flow curve of six males and females with different anticoagulant were measured using FNR. In this experiment, EDTA and Heparin were chosen as anticoagulant for blood. Heparin can inhibit the coagulation of human blood by activating the body of anti-thrombin. To examine the effect of human blood viscosity on anticoagulant, flow curve was measured at high shear rate (>350s-1), and apparent viscosity of each person were determined with different anticoagulant. The apparent viscosity of human blood with heparin was 2%-9% higher than that with EDTA. However, the difference of blood viscosity for two anticoagulants for same blood was different for each. Further discussion, we need the consideration of effect on other physical property, such as cellular component and plasma component.

Keywords: falling-needle rheometer, human blood, viscosity, anticoagulant

Procedia PDF Downloads 415
5556 Blood Pressure and Anthropometric Measurements: A Correlational Study

Authors: Abdul-Monim Batiha, Manar AlAzzam, Mohammed ALBashtawy, Loai Tawalbeh, Ahmad Tubaishat, Fadwa N. Alhalaiqa

Abstract:

Background: Obesity is the major modifiable risk factor for many chronic illnesses especially high blood pressure. Objectives: To evaluate the relationship between anthropometric indices and high blood pressure, and which one was most strongly correlated with high blood pressure in Jordanian population. Methods: A cross-sectional study was conducted with a total 622 students and workers from three Jordanian universities. Results: Nearly half of the participant are overweight (34.7%) and obese (15.4%) and hypertension was detected among 138 (22.2%) of the participants. Linear correlation was significant (p<0.01) between both systolic blood pressure and diastolic blood pressure for all anthropometric indices, except for A body shape index and diastolic blood pressure was significant at p< 0.05. Stepwise multiple linear regression analysis was used to assess the influence of age and anthropometric measurements. Conclusions: The waist circumference was the only independent predictor of hypertension, showing that this simple measurement may be an importance marker of high blood pressure in Jordanian population.

Keywords: anthropometric indices, Jordan, blood pressure, cross-sectional study, obesity, hypertension, waist circumference

Procedia PDF Downloads 264
5555 A Physiological Approach for Early Detection of Hemorrhage

Authors: Rabie Fadil, Parshuram Aarotale, Shubha Majumder, Bijay Guargain

Abstract:

Hemorrhage is the loss of blood from the circulatory system and leading cause of battlefield and postpartum related deaths. Early detection of hemorrhage remains the most effective strategy to reduce mortality rate caused by traumatic injuries. In this study, we investigated the physiological changes via non-invasive cardiac signals at rest and under different hemorrhage conditions simulated through graded lower-body negative pressure (LBNP). Simultaneous electrocardiogram (ECG), photoplethysmogram (PPG), blood pressure (BP), impedance cardiogram (ICG), and phonocardiogram (PCG) were acquired from 10 participants (age:28 ± 6 year, weight:73 ± 11 kg, height:172 ± 8 cm). The LBNP protocol consisted of applying -20, -30, -40, -50, and -60 mmHg pressure to the lower half of the body. Beat-to-beat heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean aerial pressure (MAP) were extracted from ECG and blood pressure. Systolic amplitude (SA), systolic time (ST), diastolic time (DT), and left ventricle Ejection time (LVET) were extracted from PPG during each stage. Preliminary results showed that the application of -40 mmHg i.e. moderate stage simulated hemorrhage resulted significant changes in HR (85±4 bpm vs 68 ± 5bpm, p < 0.01), ST (191 ± 10 ms vs 253 ± 31 ms, p < 0.05), LVET (350 ± 14 ms vs 479 ± 47 ms, p < 0.05) and DT (551 ± 22 ms vs 683 ± 59 ms, p < 0.05) compared to rest, while no change was observed in SA (p > 0.05) as a consequence of LBNP application. These findings demonstrated the potential of cardiac signals in detecting moderate hemorrhage. In future, we will analyze all the LBNP stages and investigate the feasibility of other physiological signals to develop a predictive machine learning model for early detection of hemorrhage.

Keywords: blood pressure, hemorrhage, lower-body negative pressure, LBNP, machine learning

Procedia PDF Downloads 141
5554 Rapid Weight Loss in Athletes: A Look at Suppressive Effects on Immune System

Authors: Nazari Maryam, Gorji Saman

Abstract:

For most competitions, athletes usually engage in a process called rapid weight loss (RWL) and subsequent rapid weight gain (RWG) in the days preceding the event. Besides the perfection of performance, weight regulation mediates a self-image of being “a real athlete” which is mentally important as a part of the pre-competition preparation. This feeling enhances the focus and commitment of the athlete. There is a large body of evidence that weight loss, particularly in combat sports, results in several health benefits. However, intentional weight loss beyond normal levels might have unknown negative special effects on the immune system. As the results show, a high prevalence (50%) of RWL is happening among combat athletes. It seems that energy deprivation and intense exercise to reach RWL results in altered blood cell distribution through modification of body composition that, in turn, changes B and T-Lymphocyte and/or CD4 T-Helper response. Moreover, it may diminish IgG antibody levels and modulate IgG glycosylation after this course. On the other hand, some studies show suppression of signaling and regulation of IgE antibody and chemokine production are responsible for immunodeficiency following a period of low-energy availability. Some researchers hypothesize that severe glutamine depletion, which occurs during exercise and calorie restriction, is responsible for this immune system weakness. However, supplementation by this amino acid is not prescribed yet. Therefore, weight loss is achieved not only through chronic strategies (body fat losses) but also through acute manipulations prior to competition should be supervised by a sports nutritionist to minimize side effects on the immune system and other body systems.

Keywords: athletes, immune system, rapid weight loss, weight loss strategies

Procedia PDF Downloads 86
5553 Comparative Antihyperglycemic Activity of Serpentina (Andrographis paniculata) and Papait (Mollugo oppositifolia linn) Aqueous Extracts in Alloxan-Induced Diabetic Mice

Authors: Karina Marie G. Nicolas, Kimberly M. Visaya, Emmanuel R. Cauinian

Abstract:

A comparative study on the antihyperglycemic activity of aqueous extracts of Serpentina (Andrographis paniculata) and Papait (Mollugo oppositifolia linn) administered at 400mg/kg body weight per orem twice daily for 14 days was investigated using 24 alloxan-induced diabetic male, 6-8 weeks old ICR mice and Metformin as standard control. The blood glucose levels of all the animals in the treatment groups were not reduced to < 200mg/dl so as to consider them as non-diabetic but Papait showed a consistent blood glucose lowering effect from day 0 to 14 causing 36.07% reduction as compared to Serpentina which was observed to cause a fluctuating effect on blood glucose levels and a reduction of only 22.53% while the Metformin treated animals exhibited the highest reduction at 45.29%. The blood glucose levels at day 14 of animals treated with Papait (322.93 mg/dl) had comparable blood glucose levels (p<0.05) with the Metformin treated groups (284.50 mg/dl). Also, all the animals in the three treatment groups were still hypercholesterolemic with an observed consistent weight loss and a decrease in feed intake except for Serpentina which recorded a slight increase. Results of the study showed a superior antihyperglycemic activity of Papait compared with Serpentina.

Keywords: antihyperglycemic, diabetes, hypercholesterolemic, papait, serpentina

Procedia PDF Downloads 335
5552 Ultrasensitive Hepatitis B Virus Detection in Blood Using Nano-Porous Silicon Oxide: Towards POC Diagnostics

Authors: N. Das, N. Samanta, L. Pandey, C. Roy Chaudhuri

Abstract:

Early diagnosis of infection like Hep-B virus in blood is important for low cost medical treatment. For this purpose, it is desirable to develop a point of care device which should be able to detect trace quantities of the target molecule in blood. In this paper, we report a nanoporous silicon oxide sensor which is capable of detecting down to 1fM concentration of Hep-B surface antigen in blood without the requirement of any centrifuge or pre-concentration. This has been made possible by the presence of resonant peak in the sensitivity characteristics. This peak is observed to be dependent only on the concentration of the specific antigen and not on the interfering species in blood serum. The occurrence of opposite impedance change within the pores and at the bottom of the pore is responsible for this effect. An electronic interface has also been designed to provide a display of the virus concentration.

Keywords: impedance spectroscopy, ultrasensitive detection in blood, peak frequency, electronic interface

Procedia PDF Downloads 374