Search results for: core needle biopsy
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2275

Search results for: core needle biopsy

2095 Preparing a Library of Abnormal Masses for Designing a Long-Lasting Anatomical Breast Phantom for Ultrasonography Training

Authors: Nasibullina A., Leonov D.

Abstract:

The ultrasonography method is actively used for the early diagnosis of various le-sions in the human body, including the mammary gland. The incidence of breast cancer has increased by more than 20%, and mortality by 14% since 2008. The correctness of the diagnosis often directly depends on the qualifications and expe-rience of a diagnostic medical sonographer. That is why special attention should be paid to the practical training of future specialists. Anatomical phantoms are ex-cellent teaching tools because they accurately imitate the characteristics of real hu-man tissues and organs. The purpose of this work is to create a breast phantom for practicing ultrasound diagnostic skills in grayscale and elastography imaging, as well as ultrasound-guided biopsy sampling. We used silicone-like compounds ranging from 3 to 17 on the Shore scale hardness units to simulate soft tissue and lesions. Impurities with experimentally selected concentrations were added to give the phantom the necessary attenuation and reflection parameters. We used 3D modeling programs and 3D printing with PLA plastic to create the casting mold. We developed a breast phantom with inclusions of varying shape, elasticity and echogenicity. After testing the created phantom in B-mode and elastography mode, we performed a survey asking 19 participants how realistic the sonograms of the phantom were. The results showed that the closest to real was the model of the cyst with 9.5 on the 0-10 similarity scale. Thus, the developed breast phantom can be used for ultrasonography, elastography, and ultrasound-guided biopsy training.

Keywords: breast ultrasound, mammary gland, mammography, training phantom, tissue-mimicking materials

Procedia PDF Downloads 95
2094 Prevalence of Lupus Glomerulonephritis in Renal Biopsies in an Eastern Region of the Arab World

Authors: M. Fayez Al Homsi, Reem Al Homsi

Abstract:

Renal disease is a major cause of morbidity and mortality. Glomerular diseases make a small portion of the renal disease. Lupus glomerulonephritis (GN) is the commonest among the GN of systemic diseases. More than a hundred and eighty-eight consecutive renal biopsies are performed and evaluated for clinically suspected glomerular diseases over a period of two years. As in a standard practice after receiving the ultrasound-guided renal biopsies, the fresh biopsy is divided to three parts, one part is frozen for immunofluorescence evaluation, the second part is placed in 4% glutaraldehyde for electron microscopic evaluation, and the third part is placed in 10% buffered formalin for light microscopic evaluation. Primary glomerular diseases are detected in 83 biopsies; glomerulonephritis (GN) of systemic diseases are identified in 88, glomerular lesions in vascular diseases in 3, glomerular lesions in metabolic diseases in 7, hereditary nephropathies in 2, end-stage kidney in 2, and glomerular lesions in transplantation in 3 biopsies. Among the primary lesions, focal segmental glomerulosclerosis (28) and mesangial proliferative GN (26) were the most common. Lupus GN (67) and Ig A nephropathy (20) were the most common of the GN of systemic diseases. Lupus nephritis biopsies included one biopsy diagnosed as class 1 (normal), 17 biopsies class 2 (mesangial proliferation), 5 biopsies class 3 (focal proliferative GN), 39 biopsies class 4 diffuse proliferative GN), 3 biopsies class 5 (membranous GN), and 2 biopsies class 6 (crescentic GN). Lupus GN is the most common among GN of systemic diseases. While diabetes is very common here, diabetic GN (3 biopsies) is not as common as might one expects. Most likely this is due to sampling and reluctance on part of nephrologists and patients in sampling the kidney in diabetes mellitus.

Keywords: diabetes, glomerulonephritis, lupus, mesangial proliferation, nephropathy

Procedia PDF Downloads 133
2093 Human Rights as Part of the Core Values System of International Organisations: A Comparative Study

Authors: Ayyoub Jamali, Jennie Edlund, Alena Kozlová

Abstract:

This paper evaluates the monitoring, prevention, and enforcing mechanisms of the core values of international organisations (IOs) in a comparative human rights perspective. The IOs in focus are the European Union, the Council of Europe, the African Union, and the Organization of American States. The paper will take the founding treaties of these IOs and their relevant protocols as a starting point to identify the values and the mechanisms used for their implementation. It will explore the scope of violations, the procedures in place and evaluate what type of response to those breaches seems to work best in terms of achieving its declared objectives. The study will identify and compare the weaknesses and strengths of each mechanism used by the IOs and recognize common challenges and means, thereby drawing inter-organizational comparisons. Consequently, the findings of this paper can be used among the IOs to improve their system and thus enhance their effectiveness.

Keywords: international organizations, core values, human rights, enforcement mechanism, compliance

Procedia PDF Downloads 183
2092 Evaluation of 18F Fluorodeoxyglucose Positron Emission Tomography, MRI, and Ultrasound in the Assessment of Axillary Lymph Node Metastases in Patients with Early Stage Breast Cancer

Authors: Wooseok Byon, Eunyoung Kim, Junseong Kwon, Byung Joo Song, Chan Heun Park

Abstract:

Purpose: 18F Fluorodeoxyglucose Positron Emission Tomography (FDG-PET) is a noninvasive imaging modality that can identify nodal metastases in women with primary breast cancer. The aim of this study was to compare the accuracy of FDG-PET with MRI and sonography scanning to determine axillary lymph node status in patients with breast cancer undergoing sentinel lymph node biopsy or axillary lymph node dissection. Patients and Methods: Between January and December 2012, ninety-nine patients with breast cancer and clinically negative axillary nodes were evaluated. All patients underwent FDG-PET, MRI, ultrasound followed by sentinel lymph node biopsy (SLNB) or axillary lymph node dissection (ALND). Results: Using axillary lymph node assessment as the gold standard, the sensitivity and specificity of FDG-PET were 51.4% (95% CI, 41.3% to 65.6%) and 92.2% (95% CI, 82.7% to 97.4%) respectively. The sensitivity and specificity of MRI and ultrasound were 57.1% (95% CI, 39.4% to 73.7%), 67.2% (95% CI, 54.3% to 78.4%) and 42.86% (95% CI, 26.3% to 60.7%), 92.2% (95% CI, 82.7% to 97.4%). Stratification according to hormone receptor status showed an increase in specificity when negative (FDG-PET: 42.3% to 77.8%, MRI 50% to 77.8%, ultrasound 34.6% to 66.7%). Also, positive HER2 status was associated with an increase in specificity (FDG-PET: 42.9% to 85.7%, MRI 50% to 85.7%, ultrasound 35.7% to 71.4%). Conclusions: The sensitivity and specificity of FDG-PET compared with MRI and ultrasound was high. However, FDG-PET is not sufficiently accurate to appropriately identify lymph node metastases. This study suggests that FDG-PET scanning cannot replace histologic staging in early-stage breast cancer, but might have a role in evaluating axillary lymph node status in hormone receptor negative or HER-2 overexpressing subtypes.

Keywords: axillary lymph node metastasis, FDG-PET, MRI, ultrasound

Procedia PDF Downloads 376
2091 Effect of Core Stability Exercises on Trunk Muscle Balance in Healthy Adult Individuals

Authors: Amira A. A. Abdallah, Amir A. Beltagi

Abstract:

Background: Core stability training has recently attracted attention for improving muscle balance and optimizing performance in healthy and unhealthy individuals. Purpose: This study investigated the effect of beginner’s core stability exercises on trunk flexors’/extensors’ peak torque ratio and trunk flexors’ and extensors’ peak torques. Methods: Thirty five healthy individuals participated in the study. They were randomly assigned to two groups; experimental “group I, n=20” and control “group II, n=15”. Their mean age, weight and height were 20.7±2.4 vs. 20.3±0.61 years, 66.5±12.1 vs. 68.57±12.2 kg and 166.7±7.8 vs. 164.28 ±7.59 cm. for group I vs. group II. Data were collected using the Biodex Isokinetic system. The participants were tested twice; before and after a 6-week period during which group I performed a core stability training program. Results: The 2x2 Mixed Design ANOVA revealed that there were no significant differences (p>0.025) in the trunk flexors’/extensors’ peak torque ratio between the pre-test and post-test conditions for either group. Moreover, there were no significant differences (p>0.025) in the trunk flexion/extension ratios between both groups at either condition. However, the 2x2 Mixed Design MANOVA revealed significant increases (p<0.025) in the trunk flexors’ and extensors’ peak torques in the post-test condition compared with the pre-test in group I with no significant differences (p>0.025) in group II. Moreover, there was a significant increase (p<0.025) in the trunk flexors’ peak torque only in group I compared with group II in the post-test condition with no significant differences in the other conditions. Interpretation/Conclusion: The improvement in muscle performance indicated by the increase in the trunk flexors’ and extensors’ peak torques in the experimental group recommends including core stability training in the exercise programs that aim to improve muscle performance.

Keywords: core stability, isokinetic, trunk muscles, muscle balance

Procedia PDF Downloads 262
2090 Human Par14 and Par17 Isomerases Bind Hepatitis B Virus Components Inside and Out

Authors: Umar Saeed

Abstract:

Peptidyl-prolyl cis/trans isomerases Par14 and Par17 in humans play crucial roles in diverse cellular processes, including protein folding, chromatin remodeling, DNA binding, ribosome biogenesis, and cell cycle progression. However, the effects of Par14 and Par17 on viral replication have been explored to a limited extent. We first time discovered their influential roles in promoting Hepatitis B Virus replication. In this study, we observed that in the presence of HBx, either Par14 or Par17 could upregulate HBV replication. However, in the absence of HBx, neither Par14 nor Par17 had any effect on replication. Their mechanism of action involves binding to specific motifs within HBc and HBx proteins. Notably, they target the conserved 133Arg-Pro134 (RP) motif of HBc and the 19RP20-28RP29 motifs of HBx. This interaction is fundamental for the stability of HBx, core particles, and HBc. Par14 and Par17 exhibit versatility by binding both outside and inside core particles, thereby facilitating core particle assembly through their participation in HBc dimer-dimer interactions. NAGE and immunoblotting analyses unveiled the binding of Par14/Par17 to core particles. Co-immunoprecipitation experiments further demonstrated the interaction of Par14/Par17 with core particle assembly-defective and dimer-positive HBc-Y132A. It's essential to emphasize that R133 is the key residue in the HBc RP motif that governs their interaction with Par14/Par17. Chromatin immunoprecipitation conducted on HBV-infected cells elucidated the participation of residues S19 and E46/D74 in Par14 and S44 and E71/D99 in Par17 in the recruitment of 133RP134 motif-containing HBc into cccDNA. Depleting PIN4 in liver cell lines results in a significant reduction in cccDNA levels, pgRNA, sgRNAs, HBc, core particle assembly, and HBV DNA synthesis. Notably, parvulin inhibitors like juglone and PiB have proven to be effective in substantially reducing HBV replication. These inhibitors weaken the interaction between HBV core particles and Par14/Par17, underscoring the dynamic nature of this interaction. It's also worth noting that specific Par14/Par17 inhibitors hold promise as potential therapeutic options for chronic hepatitis B.

Keywords: Par14Par17, HBx, HBc, cccDNA, HBV

Procedia PDF Downloads 74
2089 Evaluation of Diagnostic Values of Culture, Rapid Urease Test, and Histopathology in the Diagnosis of Helicobacter pylori Infection and in vitro Effects of Various Antimicrobials against Helicobacter pylori

Authors: Recep Kesli, Huseyin Bilgin, Yasar Unlu, Gokhan Gungor

Abstract:

Aim: The aim of this study, was to investigate the presence of Helicobacter pylori (H. pylori) infection by culture, histology, and RUT (Rapid Urease Test) in gastric antrum biopsy samples taken from patients presented with dyspeptic complaints and to determine resistance rates of amoxicillin, clarithromycin, levofloxacin and metronidazole against the H. pylori strains by E-test. Material and Methods: A total of 278 patients who admitted to Konya Education and Research Hospital Department of Gastroenterology with dyspeptic complaints, between January 2011-July 2013, were included in the study. Microbiological and histopathological examinations of biopsy specimens taken from antrum and corpus regions were performed. The presence of H. pylori in biopsy samples was investigated by culture (Portagerm pylori-PORT PYL, Pylori agar-PYL, GENbox microaer, bioMerieux, France), histology (Giemsa, Hematoxylin and Eosin staining), and RUT(CLOtest, Cimberly-Clark, USA). Antimicrobial resistance of isolates against amoxicillin, clarithromycin, levofloxacin, and metronidazole was determined by E-test method (bioMerieux, France). As a gold standard in the diagnosis of H. pylori; it was accepted that the culture method alone was positive or both histology and RUT were positive together. Sensitivity and specificity for histology and RUT were calculated by taking the culture as a gold standard. Sensitivity and specificity for culture were also calculated by taking the co-positivity of both histology and RUT as a gold standard. Results: H. pylori was detected in 140 of 278 of patients with culture and 174 of 278 of patients with histology in the study. H. pylori positivity was also found in 191 patients with RUT. According to the gold standard criteria, a false negative result was found in 39 cases by culture method, 17 cases by histology, and 8 cases by RUT. Sensitivity and specificity of the culture, histology, and RUT methods of the patients were 76.5 % and 88.3 %, 87.8 % and 63 %, 94.2 % and 57.2 %, respectively. Antibiotic resistance was investigated by E-test in 140 H. pylori strains isolated from culture. The resistance rates of H. pylori strains to the amoxicillin, clarithromycin, levofloxacin, and metronidazole was detected as 9 (6.4 %), 22 (15.7 %), 17 (12.1 %), 57 (40.7 %), respectively. Conclusion: In our study, RUT was found to be the most sensitive, culture was the most specific test between culture, histology, and RUT methods. Although we detected the specificity of the culture method as high, its sensitivity was found to be quite low compared to other methods. The low sensitivity of H. pylori culture may be caused by the factors affect the chances of direct isolation such as spoild bacterium, difficult-to-breed microorganism, clinical sample retrieval, and transport conditions.

Keywords: antimicrobial resistance, culture, histology, H. pylori, RUT

Procedia PDF Downloads 165
2088 Incidence of Idiopathic Inflammatory Myopathies and Their Risk of Cancer in Leeds, UK: An 11-year Epidemiological Study

Authors: Benoit Jauniaux, Azzam Ismail

Abstract:

Objectives: The aims were to identify all incident adult cases of idiopathic inflammatory myopathies (IIMs) in the City of Leeds, UK, and to estimate the risk of cancer in IIMs as compared with the general population. Methods: Cases of IIMs were ascertained by review of all muscle biopsy reports from the Neuropathology Laboratory. A review of medical records was undertaken for each case to review the clinical diagnosis and collect epidemiological data such as age, ethnicity, sex, and comorbidities, including cancer. Leeds denominator population numbers were publicly obtainable. Results: Two hundred and six biopsy reports were identified, and after review, 50 incident cases were included in the study between June 2010 and January 2021. Out of the 50 cases, 27 were male, and 23 were female. The mean incidence rate of IIMs in Leeds throughout the study period was 7.42/1 000 000 person years. The proportion of IIMs cases with a confirmed malignancy was 22%. Compared to the general population, the relative risk of cancer was significantly greater in the IIMs population(31.56, P < 0.01). Conclusions: The incidence rate of IIMs in Leeds was consistent with data from previous literature, however, disagreement exists between different methods of IIMs case inclusion due to varying clinical criteria and definitions. IIMs are associated with increased risk of cancer however, the pathogenesis of this relationship still requires investigating. This study supports the practice of malignancy screening and long-term surveillance in patients with IIMs.

Keywords: idiopathic inflammatory myopathies, myositis, polymyositis, dermatomyositis, malignancy, epidemiology, incidence rate, relative risk

Procedia PDF Downloads 178
2087 Neural Network Supervisory Proportional-Integral-Derivative Control of the Pressurized Water Reactor Core Power Load Following Operation

Authors: Derjew Ayele Ejigu, Houde Song, Xiaojing Liu

Abstract:

This work presents the particle swarm optimization trained neural network (PSO-NN) supervisory proportional integral derivative (PID) control method to monitor the pressurized water reactor (PWR) core power for safe operation. The proposed control approach is implemented on the transfer function of the PWR core, which is computed from the state-space model. The PWR core state-space model is designed from the neutronics, thermal-hydraulics, and reactivity models using perturbation around the equilibrium value. The proposed control approach computes the control rod speed to maneuver the core power to track the reference in a closed-loop scheme. The particle swarm optimization (PSO) algorithm is used to train the neural network (NN) and to tune the PID simultaneously. The controller performance is examined using integral absolute error, integral time absolute error, integral square error, and integral time square error functions, and the stability of the system is analyzed by using the Bode diagram. The simulation results indicated that the controller shows satisfactory performance to control and track the load power effectively and smoothly as compared to the PSO-PID control technique. This study will give benefit to design a supervisory controller for nuclear engineering research fields for control application.

Keywords: machine learning, neural network, pressurized water reactor, supervisory controller

Procedia PDF Downloads 159
2086 The Diverse and Flexible Coping Strategies Simulation for Maanshan Nuclear Power Plant

Authors: Chin-Hsien Yeh, Shao-Wen Chen, Wen-Shu Huang, Chun-Fu Huang, Jong-Rong Wang, Jung-Hua Yang, Yuh-Ming Ferng, Chunkuan Shih

Abstract:

In this research, a Fukushima-like conditions is simulated with TRACE and RELAP5. Fukushima Daiichi Nuclear Power Plant (NPP) occurred the disaster which caused by the earthquake and tsunami. This disaster caused extended loss of all AC power (ELAP). Hence, loss of ultimate heat sink (LUHS) happened finally. In order to handle Fukushima-like conditions, Taiwan Atomic Energy Council (AEC) commanded that Taiwan Power Company should propose strategies to ensure the nuclear power plant safety. One of the diverse and flexible coping strategies (FLEX) is a different water injection strategy. It can execute core injection at 20 Kg/cm2 without depressurization. In this study, TRACE and RELAP5 were used to simulate Maanshan nuclear power plant, which is a three loops PWR in Taiwan, under Fukushima-like conditions and make sure the success criteria of FLEX. Reducing core cooling ability is due to failure of emergency core cooling system (ECCS) in extended loss of all AC power situation. The core water level continues to decline because of the seal leakage, and then FLEX is used to save the core water level and make fuel rods covered by water. The result shows that this mitigation strategy can cool the reactor pressure vessel (RPV) as soon as possible under Fukushima-like conditions, and keep the core water level higher than Top of Active Fuel (TAF). The FLEX can ensure the peak cladding temperature (PCT) below than the criteria 1088.7 K. Finally, the FLEX can provide protection for nuclear power plant and make plant safety.

Keywords: TRACE, RELAP5/MOD3.3, ELAP, FLEX

Procedia PDF Downloads 252
2085 The Effect of Exercise, Reflexology and Chrome on Metabolic Syndrome

Authors: F. Arslan, S.D. Guven, A. Özcan, H. Vatansev, Ö. Taşgin

Abstract:

Weight, hypertension and dyslipidemia control and increased physical activity are required for the treatment of metabolic syndrome (METS). The purpose of this study was to investigate the effect of core exercise, reflexology and intake chrome picolinate on METS. This study comprised a twelve-week randomized controlled trial. A total of 25 university workers with metabolic risk factors participated in this study voluntarily. They were randomly divided into three groups: Those undertaking a core exercise program (n=7), reflexology intervention group (n=8) and intake chrome group (n=10). The subjects took part in a core exercise program for one hour per day, three days a week and a reflexology interfered for thirty minutes per day, one days a week and chrome group took chrome picolinate every day in week for twelve weeks. The components of metabolic syndrome were analyzed before and after the completion of all the intervention. There were significant differences at pre-prandial blood glucose in the core exercise group and at systolic blood pressure in chrome group after the twelve week interventions (p < 0.005). While High Density Lipoprotein (HDL) excluding the components of METS decreased after the interventions on the all groups; levels of HDL and the other components of METS decreased in reflexology group. There was a clear response to the twelve-week interventions in terms of METS control. Besides, the reflexology intervention should not be applied to individuals with low HDL levels and core exercise and intake chrome picolinate suggested to improve the components of METS.

Keywords: blood pressure, body mass index, exercise, METS, pre-prandial blood glucose

Procedia PDF Downloads 446
2084 International Criminal Prosecution and Core International Crimes

Authors: Ikediobi Lottanna Samuel

Abstract:

Days are gone when perpetrators of core international crimes hide under the cloak of sovereignty to go with impunity. The principle of international criminal responsibility is a reality. This move to end impunity for violation of human rights has led to the creation of international and hybrid tribunals, a permanent international criminal court, and increased prosecution of human rights violations in domestic courts. This article examines the attempts by the international community to bring perpetrators of heinous crimes to book. The work reveals the inadequacy of the current international mechanism for prosecuting core international crimes in order to end the culture of impunity and entrench the culture of accountability. It also identifies that ad hoc international criminal tribunals and the international criminal court face similar challenges ranging from lack of cooperation by nation states, non-existence of hierarchy of crimes, lack of effective enforcement mechanism, limited prosecutorial capacity and agenda, difficulty in apprehending suspects, difficulty in blending different legal tradition, absence of a coherent sentencing guideline, distant location of courts, selective indictment, etc. These challenges adversely affect the functioning of these courts. It is suggested that a more helpful way to end impunity would be to have a more robust and synergistic relationship between national, regional, and international approaches to prosecuting core international crimes.

Keywords: prosecution, criminal, international, tribunal, justice, ad hoc

Procedia PDF Downloads 218
2083 Measurements of Flow Mixing Behaviors Using a Wire-Mesh Sensor in a Wire-Wrapped 37-Pin Rod Assembly

Authors: Hyungmo Kim, Hwang Bae, Seok-Kyu Chang, Dong Won Lee, Yung Joo Ko, Sun Rock Choi, Hae Seob Choi, Hyeon Seok Woo, Dong-Jin Euh, Hyeong-Yeon Lee

Abstract:

Flow mixing characteristics in the wire-wrapped 37-pin rod bundle were measured by using a wire-mesh sensing system for a sodium-cooled fast reactor (SFR). The subchannel flow mixing in SFR core subchannels was an essential characteristic for verification of a core thermal design and safety analysis. A dedicated test facility including the wire-mesh sensor system and tracing liquid injection system was developed, and the conductivity fields at the end of 37-pin rod bundle were visualized in several different flow conditions. These experimental results represented the reasonable agreements with the results of CFD, and the uncertainty of the mixing experiments has been conducted to evaluate the experimental results.

Keywords: core thermal design, flow mixing, a wire-mesh sensor, a wire-wrap effect

Procedia PDF Downloads 633
2082 Investigation of Resistive Switching in CsPbCl₃ / Cs₄PbCl₆ Core-Shell Nanocrystals Using Scanning Tunneling Spectroscopy: A Step Towards High Density Memory-based Applications

Authors: Arpan Bera, Rini Ganguly, Raja Chakraborty, Amlan J. Pal

Abstract:

To deal with the increasing demands for the high-density non-volatile memory devices, we need nano-sites with efficient and stable charge storage capabilities. We prepared nanocrystals (NCs) of inorganic perovskite, CsPbCl₃ coated with Cs₄PbCl₆, by colloidal synthesis. Due to the type-I band alignment at the junction, this core-shell composite is expected to behave as a charge trapping site. Using Scanning Tunneling Spectroscopy (STS), we investigated voltage-controlled resistive switching in this heterostructure by tracking the change in its current-voltage (I-V) characteristics. By applying voltage pulse of appropriate magnitude on the NCs through this non-invasive method, different resistive states of this system were systematically accessed. For suitable pulse-magnitude, the response jumped to a branch with enhanced current indicating a high-resistance state (HRS) to low-resistance state (LRS) switching in the core-shell NCs. We could reverse this process by using a pulse of opposite polarity. These two distinct resistive states can be considered as two logic states, 0 and 1, which are accessible by varying voltage magnitude and polarity. STS being a local probe in space enabled us to capture this switching at individual NC site. Hence, we claim a bright prospect of these core-shell NCs made of inorganic halide perovskites in future high density memory application.

Keywords: Core-shell perovskite, CsPbCl₃-Cs₄PbCl₆, resistive switching, Scanning Tunneling Spectroscopy

Procedia PDF Downloads 90
2081 Comparison of Pbs/Zns Quantum Dots Synthesis Methods

Authors: Mahbobeh Bozhmehrani, Afshin Farah Bakhsh

Abstract:

Nanoparticles with PbS core of 12 nm and shell of approximately 3 nm were synthesized at PbS:ZnS ratios of 1.01:0.1 using Merca Ptopropionic Acid as stabilizing agent. PbS/ZnS nanoparticles present a dramatically increase of Photoluminescence intensity, confirming the confinement of the PbS core by increasing the Quantum Yield from 0.63 to 0.92 by the addition of the ZnS shell. In this case, the synthesis by microwave method allows obtaining nanoparticles with enhanced optical characteristics than those of nanoparticles synthesized by colloidal method.

Keywords: Pbs/Zns, quantum dots, colloidal method, microwave

Procedia PDF Downloads 290
2080 Dynamic Stability of a Wings for Drone Aircraft Subjected to Parametric Excitation

Authors: Iyd Eqqab Maree, Habil Jurgen Bast

Abstract:

Vibration control of machines and structures incorporating viscoelastic materials in suitable arrangement is an important aspect of investigation. The use of viscoelastic layers constrained between elastic layers is known to be effective for damping of flexural vibrations of structures over a wide range of frequencies. The energy dissipated in these arrangements is due to shear deformation in the viscoelastic layers, which occurs due to flexural vibration of the structures. Multilayered cantilever sandwich beam like structures can be used in aircrafts and other applications such as robot arms for effective vibration control. These members may experience parametric instability when subjected to time dependant forces. The theory of dynamic stability of elastic systems deals with the study of vibrations induced by pulsating loads that are parametric with respect to certain forms of deformation. The purpose of the present work is to investigate the dynamic stability of a three layered symmetric sandwich beam (Drone Aircraft wings ) subjected to an end periodic axial force . Equations of motion are derived using finite element method (MATLAB software). It is observed that with increase in core thickness parameter fundamental buckling load increases. The fundamental resonant frequency and second mode frequency parameter also increase with increase in core thickness parameter. Fundamental loss factor and second mode loss factor also increase with increase in core thickness parameter. Increase in core thickness parameter enhances the stability of the beam. With increase in core loss factor also the stability of the beam enhances. There is a very good agreement of the experimental results with the theoretical findings.

Keywords: steel cantilever beam, viscoelastic material core, loss factor, transition region, MATLAB R2011a

Procedia PDF Downloads 478
2079 Hydraulic Studies on Core Components of PFBR

Authors: G. K. Pandey, D. Ramadasu, I. Banerjee, V. Vinod, G. Padmakumar, V. Prakash, K. K. Rajan

Abstract:

Detailed thermal hydraulic investigations are very essential for safe and reliable functioning of liquid metal cooled fast breeder reactors. These investigations are further more important for components with complex profile, since there is no direct correlation available in literature to evaluate the hydraulic characteristics of such components directly. In those cases available correlations for similar profile or geometries may lead to significant uncertainty in the outcome. Hence experimental approach can be adopted to evaluate these hydraulic characteristics more precisely for better prediction in reactor core components. Prototype Fast Breeder Reactor (PFBR), a sodium cooled pool type reactor is under advanced stage of construction at Kalpakkam, India. Several components of this reactor core require hydraulic investigation before its usage in the reactor. These hydraulic investigations on full scale models, carried out by experimental approaches using water as simulant fluid are discussed in the paper.

Keywords: fast breeder reactor, cavitation, pressure drop, reactor components

Procedia PDF Downloads 465
2078 Meaningful General Education Reform: Integrating Core Curricula and Institutional Values

Authors: Michael W. Markowitz

Abstract:

A central element of higher education today is the “core” or “general education” curriculum: that configuration of courses that often encompasses the essence of liberal arts education. Ensuring that such offerings reflect the mission and values of the institution is a challenge faced by most college and universities, often more than once. This paper presents an action model of program planning designed to structure the processes of developing, implementing and revising core curricula in a manner consistent with key institutional goals and objectives. Through presentation of a case study from a university in the United States, the elements of needs assessment, stakeholder investment and collaborative compromise are shown as key components of a planning strategy that can produce a general education program that is comprehensive, academically rigorous, assessable and mission consistent. The paper concludes with recommendations for both the implementation and evaluation of such programs in practice.

Keywords: academic assessment, academic program planning, curriculum development, general education reform

Procedia PDF Downloads 321
2077 Numerical Investigation of Fiber-Reinforced Polymer (FRP) Panels Resistance to Blast Loads

Authors: Sameh Ahmed, Khaled Galal

Abstract:

Fiber-reinforced polymer (FRP) sandwich panels are increasingly making their way into structural engineering applications. One of these applications is the blast mitigation. This is attributed to FRP ability of absorbing considerable amount of energy relative to their low density. In this study, FRP sandwich panels are numerically studied using an explicit finite element code ANSYS AUTODYN. The numerical model is then validated with the experimental field tests in the literature. The inner core configurations that have been studied in the experimental field tests were formed from different orientations of the honeycomb shape. On the other hand, the conducted numerical study has proposed a new core configuration. The new core configuration is formulated from a combination of woven and honeycomb shapes. Throughout this study, two performance parameters are considered; the amount of the energy absorbed by the panels and the peak deformation of the panels. Following, a parametric study has been conducted with more variations of the studied parameters to examine the enhancement of the panels' performance. It is found that the numerical results have shown a good agreement with the experimental measurements. Furthermore, the analyses have revealed that using the proposed core configuration obviously enhances the FRP panels’ behavior when subjected to blast loads.

Keywords: blast load, fiber reinforced polymers, finite element modeling, sandwich panels

Procedia PDF Downloads 313
2076 An Audit on the Role of Sentinel Node Biopsy in High-Risk Ductal Carcinoma in Situ and Intracystic Papillary Carcinoma

Authors: M. Sulieman, H. Arabiyat, H. Ali, K. Potiszil, I. Abbas, R. English, P. King, I. Brown, P. Drew

Abstract:

Introduction: The incidence of breast ductal Carcinoma in Situ (DCIS) has been increasing; it currently represents up 20-25% of all breast carcinomas. Some aspects of DCIS management are still controversial, mainly due to the heterogeneity of its clinical presentation and of its biological and pathological characteristics. In DCIS, histological diagnosis obtained preoperatively, carries the risk of sampling error if the presence of invasive cancer is subsequently diagnosed. The mammographic extent over than 4–5 cm and the presence of architectural distortion, focal asymmetric density or mass on mammography are proven important risk factors of preoperative histological under staging. Intracystic papillary cancer (IPC) is a rare form of breast carcinoma. Despite being previously compared to DCIS it has been shown to present histologically with invasion of the basement membrane and even metastasis. SLNB – Carries the risk of associated comorbidity that should be considered when planning surgery for DCIS and IPC. Objectives: The aim of this Audit was to better define a ‘high risk’ group of patients with pre-op diagnosis of non-invasive cancer undergoing breast conserving surgery, who would benefit from sentinel node biopsy. Method: Retrospective data collection of all patients with ductal carcinoma in situ over 5 years. 636 patients identified, and after exclusion criteria applied: 394 patients were included. High risk defined as: Extensive micro-calcification >40mm OR any mass forming DCIS. IPC: Winpath search from for the term ‘papillary carcinoma’ in any breast specimen for 5 years duration;.29 patients were included in this group. Results: DCIS: 188 deemed high risk due to >40mm calcification or a mass forming (radiological or palpable) 61% of those had a mastectomy and 32% BCS. Overall, in that high-risk group - the number with invasive disease was 38%. Of those high-risk DCIS pts 85% had a SLN - 80% at the time of surgery and 5% at a second operation. For the BCS patients - 42% had SLN at time of surgery and 13% (8 patients) at a second operation. 15 (7.9%) pts in the high-risk group had a positive SLNB, 11 having a mastectomy and 4 having BCS. IPC: The provisional diagnosis of encysted papillary carcinoma is upgraded to an invasive carcinoma on final histology in around a third of cases. This has may have implications when deciding whether to offer sentinel node removal at the time of therapeutic surgery. Conclusions: We have defined a ‘high risk’ group of pts with pre-op diagnosis of non-invasive cancer undergoing BCS, who would benefit from SLNB at the time of the surgery. In patients with high-risk features; the risk of invasive disease is up to 40% but the risk of nodal involvement is approximately 8%. The risk of morbidity from SLN is up to about 5% especially the risk of lymphedema.

Keywords: breast ductal carcinoma in Situ (DCIS), intracystic papillary carcinoma (IPC), sentinel node biopsy (SLNB), high-risk, non-invasive, cancer disease

Procedia PDF Downloads 112
2075 Highly Sensitive Fiber-Optic Curvature Sensor Based on Four Mode Fiber

Authors: Qihang Zeng, Wei Xu, Ying Shen, Changyuan Yu

Abstract:

In this paper, a highly sensitive fiber-optic curvature sensor based on four mode fiber (FMF) is presented and investigated. The proposed sensing structure is constructed by fusing a section of FMF into two standard single mode fibers (SMFs) concatenated with two no core fiber (NCF), i.e., SMF-NCF-FMF-NCF-SMF structure is fabricated. The length of the NCF is very short about 1 millimeter acting as exciting/recoupling the light from/into the core of the SMF, while the FMF is with 3 centimeters long supporting four eigenmodes including LP₀₁, LP₁₁, LP₂₁ and LP₀₂. High core modes in FMF can be effectively stimulated owing to mismatched mode field distribution and the mainly sensing principle is based on modal interferometer spectrum analysis. Different curvatures induce different strains on the FMF such that affecting the modal excitation, resulting spectrum shifts. One can get the curvature value by tracking the wavelength shifting. Experiments have been done to address the sensing performance, which is about 7.8 nm/m⁻¹ within a range of 1.90 m⁻¹~3.18 m⁻¹.

Keywords: curvature, four mode fiber, highly sensitive, modal interferometer

Procedia PDF Downloads 194
2074 Numerical Study of Modulus of Subgrade Reaction in Eccentrically Loaded Circular Footing Resting

Authors: Seyed Abolhasan Naeini, Mohammad Hossein Zade

Abstract:

This article is an attempt to present a numerically study of the behaviour of an eccentrically loaded circular footing resting on sand to determine ‎its ultimate bearing capacity. A surface circular footing of diameter 12 cm (D) was used as ‎shallow foundation. For this purpose, three dimensional models consist of foundation, and medium sandy soil was modelled by ABAQUS software. Bearing capacity of footing was evaluated and the ‎effects of the load eccentricity on bearing capacity, its settlement, and modulus of subgrade reaction were studied. Three different values of load eccentricity with equal space from inside the core on the core boundary and outside the core boundary, which were respectively e=0.75, 1.5, and 2.25 cm, were considered. The results show that by increasing the load eccentricity, the ultimate load and the ‎modulus of subgrade reaction decreased.

Keywords: circular foundation, sand, eccentric loading, modulus of subgrade reaction

Procedia PDF Downloads 350
2073 Inducible Trans-Encapsidation System for Temporal Separation of Hepatitis C Virus Life Cycle

Authors: Ovidiu Vlaicu, Leontina Banica, Dan Otelea, Andrei-Jose Petrescu, Costin-Ioan Popescu

Abstract:

Hepatitis C Virus (HCV) infects 170 million peoples worldwide. Major advances have been made recently in HCV standard of care with interferon-free therapy being already approved. Despite major progress in HCV therapy, the genotype associated treatment efficacy and toxicity still represent issues to address. To identify endogenous factors involved in different stages of HCV life cycle, we have developed a trans-packaging system for HCV subgenomic replicons lacking core protein gene. Huh7 cells were used to generate a packaging cell line expressing the core protein in an inducible manner. The core packaging cell line was able to trans-complemented various subgenomic replicons to secret infectious trans-complemented HCV particles (HCV-TCP). Further, we constructed subgenomic replicons with foreign epitopes suitable for immunoaffinity purification or fluorescence microscopy studies. We have shown that the insertion has not effects on the efficacy of trans-complementation yielding similar titers to the control subgenomic replicon. This system will be a valuable tool in studying pre- and post-assembly events in HCV life cycle and for the fast identification of HCV assembly inhibitors.

Keywords: assembly inhibitors, core protein, HCV, trans-complementation

Procedia PDF Downloads 293
2072 The Effect of Core Training on Physical Fitness Characteristics in Male Volleyball Players

Authors: Sibel Karacaoglu, Fatma Ç. Kayapinar

Abstract:

The aim of the study is to investigate the effect of the core training program on physical fitness characteristics and body composition in male volleyball players. 26 male university volleyball team players aged between 19 to 24 years who had no health problems and injury participated in the study. Subjects were divided into training (TG) and control groups (CG) as randomly. Data from twenty-one players who completed all training sessions were used for statistical analysis (TG,n=11; CG,n=10). A core training program was applied to the training group three days a week for 10 weeks. On the other hand, the control group did not receive any training. Before and after the 10-week training program, pre- and post-testing comprised of body composition measurements (weight, BMI, bioelectrical impedance analysis) and physical fitness measurements including flexibility (sit and reach test), muscle strength (back, leg and grip strength by dynamometer), muscle endurance (sit-ups and push-ups tests), power (one-legged jump and vertical jump tests), speed (20m sprint, 30m sprint) and balance tests (one-legged standing test) were performed. Changes of pre- and post- test values of the groups were determined by using dependent t test. According to the statistical analysis of data, no significant difference was found in terms of body composition in the both groups for pre- and post- test values. In the training group, all physical fitness measurements improved significantly after core training program (p<0.05) except 30m speed and handgrip strength (p>0.05). On the hand, only 20m speed test values improved after post-test period (p<0.05), but the other physical fitness tests values did not differ (p>0.05) between pre- and post- test measurement in the control group. The results of the study suggest that the core training program has positive effect on physical fitness characteristics in male volleyball players.

Keywords: body composition, core training, physical fitness, volleyball

Procedia PDF Downloads 348
2071 Increase of the Nanofiber Degradation Rate Using PCL-PEO and PCL-PVP as a Shell in the Electrospun Core-Shell Nanofibers Using the Needleless Blades

Authors: Matej Buzgo, Erico Himawan, Ksenija JašIna, Aiva Simaite

Abstract:

Electrospinning is a versatile and efficient technology for producing nanofibers for biomedical applications. One of the most common polymers used for the preparation of nanofibers for regenerative medicine and drug delivery applications is polycaprolactone (PCL). PCL is a biocompatible and bioabsorbable material that can be used to stimulate the regeneration of various tissues. It is also a common material used for the development of drug delivery systems by blending the polymer with small active molecules. However, for many drug delivery applications, e.g. cancer immunotherapy, PCL biodegradation rate that may exceed 9 months is too long, and faster nanofiber dissolution is needed. In this paper, we investigate the dissolution and small molecule release rates of PCL blends with two hydrophilic polymers: polyethylene oxide (PEO) or polyvinylpyrrolidone (PVP). We show that adding hydrophilic polymer to the PCL reduces the water contact angle, increases the dissolution rate, and strengthens the interactions between the hydrophilic drug and polymer matrix that further sustain its release. Finally using this method, we were also able to increase the nanofiber degradation rate when PCL-PEO and PCL-PVP were used as a shell in the electrospun core-shell nanofibers and spread up the release of active proteins from their core. Electrospinning can be used for the preparation of the core-shell nanofibers, where active ingredients are encapsulated in the core and their release rate is regulated by the shell. However, such fibers are usually prepared by coaxial electrospinning that is an extremely low-throughput technique. An alternative is emulsion electrospinning that could be upscaled using needleless blades. In this work, we investigate the possibility of using emulsion electrospinning for encapsulation and sustained release of the growth factors for the development of the organotypic skin models. The core-shell nanofibers were prepared using the optimized formulation and the release rate of proteins from the fibers was investigated for 2 weeks – typical cell culture conditions.

Keywords: electrospinning, polycaprolactone (PCL), polyethylene oxide (PEO), polyvinylpyrrolidone (PVP)

Procedia PDF Downloads 277
2070 Differential Expression of GABA and Its Signaling Components in Ulcerative Colitis and Irritable Bowel Syndrome Pathogenesis

Authors: Surbhi Aggarwal, Jaishree Paul

Abstract:

Background: Role of GABA has been implicated in autoimmune diseases like multiple sclerosis, type1 diabetes and rheumatoid arthritis where they modulate the immune response but role in gut inflammation has not been defined. Ulcerative colitis (UC) and diarrhoeal predominant irritable bowel syndrome (IBS-D) both involve inflammation of gastrointestinal tract. UC is a chronic, relapsing and idiopathic inflammation of gut. IBS is a common functional gastrointestinal disorder characterised by abdominal pain, discomfort and alternating bowel habits. Mild inflammation is known to occur in IBS-D. Aim: Aim of this study was to investigate the role of GABA in UC as well as in IBS-D. Materials and methods: Blood and biopsy samples from UC, IBS-D and controls were collected. ELISA was used for measuring level of GABA in serum of UC, IBS-D and controls. RT-PCR analysis was done to determine GABAergic signal system in colon biopsy of UC, IBS-D and controls. RT-PCR was done to check the expression of proinflammatory cytokines. CurveExpert 1.4, Graphpad prism-6 software were used for data analysis. Statistical analysis was done by unpaired, two-way student`s t-test. All sets of data were represented as mean± SEM. A probability level of p < 0.05 was considered statistically significant. Results and conclusion: Significantly decreased level of GABA and altered GABAergic signal system was detected in UC and IBS-D as compared to controls. Significantly increased expression of proinflammatory cytokines was also determined in UC and IBS-D as compared to controls. Hence we conclude that insufficient level of GABA in UC and IBS-D leads to overproduction of proinflammatory cytokines which further contributes to inflammation. GABA may be used as a promising therapeutic target for treatment of gut inflammation or other inflammatory diseases.

Keywords: diarrheal predominant irritable bowel syndrome, γ-aminobutyric acid (GABA), inflammation, ulcerative colitis

Procedia PDF Downloads 226
2069 Effect of Different Ground Motion Scaling Methods on Behavior of 40 Story RC Core Wall Building

Authors: Muhammad Usman, Munir Ahmed

Abstract:

The demand of high-rise buildings has grown fast during the past decades. The design of these buildings by using RC core wall have been widespread nowadays in many countries. The RC core wall (RCCW) buildings encompasses central core wall and boundary columns joined through post tension slab at different floor levels. The core wall often provides greater stiffness as compared to the collective stiffness of the boundary columns. Hence, the core wall dominantly resists lateral loading i.e. wind or earthquake load. Non-linear response history analysis (NLRHA) procedure is the finest seismic design procedure of the times for designing high-rise buildings. The modern design tools for nonlinear response history analysis and performance based design has provided more confidence to design these structures for high-rise buildings. NLRHA requires selection and scaling of ground motions to match design spectrum for site specific conditions. Designers use several techniques for scaling ground motion records (time series). Time domain and frequency domain scaling are most commonly used which comprises their own benefits and drawbacks. Due to lengthy process of NLRHA, application of only one technique is conceivable. To the best of author’s knowledge, no consensus on the best procedures for the selection and scaling of the ground motions is available in literature. This research aims to provide the finest ground motion scaling technique specifically for designing 40 story high-rise RCCW buildings. Seismic response of 40 story RCCW building is checked by applying both the frequency domain and time domain scaling. Variable sites are selected in three critical seismic zones of Pakistan. The results indicates that there is extensive variation in seismic response of building for these scaling. There is still a need to build a consensus on the subjected research by investigating variable sites and buildings heights.

Keywords: 40-storied RC core wall building, nonlinear response history analysis, ground motions, time domain scaling, frequency domain scaling

Procedia PDF Downloads 135
2068 The Utility of Sonographic Features of Lymph Nodes during EBUS-TBNA for Predicting Malignancy

Authors: Atefeh Abedini, Fatemeh Razavi, Mihan Pourabdollah Toutkaboni, Hossein Mehravaran, Arda Kiani

Abstract:

In countries with the highest prevalence of tuberculosis, such as Iran, the differentiation of malignant tumors from non-malignant is very important. In this study, which was conducted for the first time among the Iranian population, the utility of the ultrasonographic morphological characteristics in patients undergoing EBUS was used to distinguish the non-malignant versus malignant lymph nodes. The morphological characteristics of lymph nodes, which consist of size, shape, vascular pattern, echogenicity, margin, coagulation necrosis sign, calcification, and central hilar structure, were obtained during Endobronchial Ultrasound-Guided Trans-Bronchial Needle Aspiration and were compared with the final pathology results. During this study period, a total of 253 lymph nodes were evaluated in 93 cases. Round shape, non-hilar vascular pattern, heterogeneous echogenicity, hyperechogenicity, distinct margin, and the presence of necrosis sign were significantly higher in malignant nodes. On the other hand, the presence of calcification and also central hilar structure were significantly higher in the benign nodes (p-value ˂ 0.05). Multivariate logistic regression showed that size>1 cm, heterogeneous echogenicity, hyperechogenicity, the presence of necrosis signs and, the absence of central hilar structure are independent predictive factors for malignancy. The accuracy of each of the aforementioned factors is 42.29 %, 71.54 %, 71.90 %, 73.51 %, and 65.61 %, respectively. Of 74 malignant lymph nodes, 100% had at least one of these independent factors. According to our results, the morphological characteristics of lymph nodes based on Endobronchial Ultrasound-Guided Trans-Bronchial Needle Aspiration can play a role in the prediction of malignancy.

Keywords: EBUS-TBNA, malignancy, nodal characteristics, pathology

Procedia PDF Downloads 138
2067 Effect of Core Stability Exercises on Balance between Trunk Muscles in Healthy Adult Subjects

Authors: Amir A. Beltagi, Ahmed R. Abdelbaki

Abstract:

Background: Core stability training has recently attracted attention for optimizing performance and improving muscle balance for healthy and unhealthy individuals. The purpose of this study was to investigate the effect of beginner’s core stability exercises on the trunk flexors’/extensors’ peak torque ratio and trunk flexors’ and extensors’ peak torques. Methods: Thirty five healthy individuals, randomly assigned into two groups; experimental (group I) and control (group II), participated in the study. Group I involved 20 participants (10 male & 10 female) with mean ±SD age, weight, and height of 20.7±2.4 years, 66.5±12.1 kg and 166.7±7.8 cm respectively. Group II involved 15 participants (6 male & 9 female) with mean ±SD age, weight, and height of 20.3±0.61 years, 68.57±12.2 kg and 164.28 ±7.59 cm respectively. Data were collected using the Biodex Isokinetic system. The participants were tested twice; before and after a 6-week period during which the experimental group performed a core stability training program. Findings: Statistical analysis using the 2x2 Mixed Design ANOVA revealed that there were no significant differences in the trunk flexors’/extensors’ peak torque ratio between the ‘pre’ and ‘post’ tests for either group (p > 0.025). Moreover, there were no significant differences in the trunk flexors’/extensors’ ratios between both groups at either test (p > 0.025). Meanwhile, the 2x2 Mixed Design MANOVA revealed that there were significant differences in the trunk flexors’ and extensors’ peak torques between the ‘pre’ and ‘post’ tests for group I (p < 0.025), while there were no significant differences inbetween for group II (p > 0.025). Moreover, there were no significant differences between both groups for the tested muscles’ peak torques at either test except for that of the trunk flexors at the ‘post’ test only (p < 0.025). Interpretation: The improvement in muscle performance indicated by the increase in the trunk flexors’ and extensors’ peak torques in the experimental group recommends including core stability training in the exercise programs that aim to improve muscle performance.

Keywords: core stability, isokinetic, trunk muscles, muscle balance

Procedia PDF Downloads 316
2066 The Core Obstacles of Continuous Improvement Implementation: Some Key Findings from Health and Education Sectors

Authors: Abdullah Alhaqbani

Abstract:

Purpose: Implementing continuous improvement is a challenge that public sector organisations face in becoming successful. Many obstacles hinder public organisations from successfully implementing continuous improvement. This paper aims to highlight the key core obstacles that face public organisations to implement continuous improvement programmes. Approach: Based on the literature, this paper reviews 66 papers that were published between 2000 and 2013 and that focused on the concept of continuous improvement and improvement methodologies in the context of public sector organisations. The methodologies for continuous improvement covered in these papers include Total Quality Management, Six Sigma, process re-engineering, lean thinking and Kaizen. Findings: Of the 24 obstacles found in the literature, 11 barriers were seen as core barriers that frequently occurred in public sector organisations. The findings indicate that lack of top management commitment; organisational culture and political issues and resistance to change are significant obstacles for improvement programmes. Moreover, this review found that improvement methodologies share some core barriers to successful implementation within public organisations. These barriers as well are common in the different geographic area. For instance lack of top management commitment and training that found in the education sector in Albanian are common barriers of improvement studies in Kuwait, Saudi Arabia, Spain, UK and US. Practical implications: Understanding these core issues and barriers will help managers of public organisations to improve their strategies with respect to continuous improvement. Thus, this review highlights the core issues that prevent a successful continuous improvement journey within the public sector. Value: Identifying and understanding the common obstacles to successfully implementing continuous improvement in the public sector will help public organisations to learn how to improve in launching and successfully sustaining such programmes. However, this is not the end; rather, it is just the beginning of a longer improvement journey. Thus, it is intended that this review will identify key learning opportunities for public sector organisations in developing nations which will then be tested via further research.

Keywords: continuous improvement, total quality management, obstacles, public sector

Procedia PDF Downloads 352