Search results for: diagnostic error
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2868

Search results for: diagnostic error

2748 Analysis of an Error Estimate for the Asymptotic Solution of the Heat Conduction Problem in a Dilated Pipe

Authors: E. Marušić-Paloka, I. Pažanin, M. Prša

Abstract:

Subject of this study is the stationary heat conduction problem through a pipe filled with incompressible viscous fluid. In previous work, we observed the existence and uniqueness theorems for the corresponding boundary-value problem and within we have taken into account the effects of the pipe's dilatation due to the temperature of the fluid inside of the pipe. The main difficulty comes from the fact that flow domain changes depending on the solution of the observed heat equation leading to a non-standard coupled governing problem. The goal of this work is to find solution estimate since the exact solution of the studied problem is not possible to determine. We use an asymptotic expansion in order of a small parameter which is presented as a heat expansion coefficient of the pipe's material. Furthermore, an error estimate is provided for the mentioned asymptotic approximation of the solution for inner area of the pipe. Close to the boundary, problem becomes more complex so different approaches are observed, mainly Theory of Perturbations and Separations of Variables. In view of that, error estimate for the whole approximation will be provided with additional software simulations of gotten situation.

Keywords: asymptotic analysis, dilated pipe, error estimate, heat conduction

Procedia PDF Downloads 208
2747 Investigating the Causes of Human Error-Induced Incidents in the Maintenance Operations of Petrochemical Industry by Using Human Factors Analysis and Classification System

Authors: Omid Kalatpour, Mohammadreza Ajdari

Abstract:

This article studied the possible causes of human error-induced incidents in the petrochemical industry maintenance activities by using Human Factors Analysis and Classification System (HFACS). The purpose of the study was anticipating and identifying these causes and proposing corrective and preventive actions. Maintenance department in a petrochemical company was selected for research. A checklist of human error-induced incidents was developed based on four HFACS main levels and nineteen sub-groups. Hierarchical task analysis (HTA) technique was used to identify maintenance activities and tasks. The main causes of possible incidents were identified by checklist and recorded. Corrective and preventive actions were defined depending on priority. Analyzing the worksheets of 444 activities in four levels of HFACS showed 37.6% of the causes were at the level of unsafe actions, 27.5% at the level of unsafe supervision, 20.9% at the level of preconditions for unsafe acts and 14% of the causes were at the level of organizational effects. The HFACS sub-groups showed errors (24.36%) inadequate supervision (14.89%) and violations (13.26%) with the most frequency. According to findings of this study, increasing the training effectiveness of operators and supervision improvement respectively are the most important measures in decreasing the human error-induced incidents in petrochemical industry maintenance.

Keywords: human error, petrochemical industry, maintenance, HFACS

Procedia PDF Downloads 209
2746 A Mathematical Model for 3-DOF Rotary Accuracy Measurement Method Based on a Ball Lens

Authors: Hau-Wei Lee, Yu-Chi Liu, Chien-Hung Liu

Abstract:

A mathematical model is presented for a system that measures rotational errors in a shaft using a ball lens. The geometric optical characteristics of the ball lens mounted on the shaft allows the measurement of rotation axis errors in both the radial and axial directions. The equipment used includes two quadrant detectors (QD), two laser diodes and a ball lens that is mounted on the rotating shaft to be evaluated. Rotational errors in the shaft cause changes in the optical geometry of the ball lens. The resulting deflection of the laser beams is detected by the QDs and their output signals are used to determine rotational errors. The radial and the axial rotational errors can be calculated as explained by the mathematical model. Results from system calibration show that the measurement error is within ±1 m and resolution is about 20 nm. Using a direct drive motor (DD motor) as an example, experimental results show a rotational error of less than 20 m. The most important features of this system are that it does not require the use of expensive optical components, it is small, very easy to set up, and measurements are highly accurate.

Keywords: ball lens, quadrant detector, axial error, radial error

Procedia PDF Downloads 441
2745 Diagnostic Value of CT Scan in Acute Appendicitis

Authors: Maria Medeiros, Suren Surenthiran, Abitha Muralithar, Soushma Seeburuth, Mohammed Mohammed

Abstract:

Introduction: Appendicitis is the most common surgical emergency globally and can have devastating consequences. Diagnostic imaging in acute appendicitis has become increasingly common in aiding the diagnosis of acute appendicitis. Computerized tomography (CT) and ultrasound (US) are the most commonly used imaging modalities for diagnosing acute appendicitis. Pre-operative imaging has contributed to a reduction of negative appendicectomy rates from between 10-29% to 5%. Literature report CT scan has a diagnostic sensitivity of 94% in acute appendicitis. This clinical audit was conducted to establish if the CT scan's diagnostic yield for acute appendicitis matches the literature. CT scan has a high sensitivity and specificity for diagnosing acute appendicitis and its use can result in a lower negative appendicectomy rate. The aim of this study is to compare the pre-operative imaging findings from CT scans to the histopathology results post-operatively and establish the accuracy of CT scans in aiding the diagnosis of acute appendicitis. Methods: This was a retrospective study focusing on adult presentations to the general surgery department in a district general hospital in central London with an impression of acute appendicitis. We analyzed all patients from July 2022 to December 2022 who underwent a CT scan preceding appendicectomy. Pre-operative CT findings and post-operative histopathology findings were compared to establish the efficacy of CT scans in diagnosing acute appendicitis. Our results were also cross-referenced with pre-existing literature. Data was collected and anonymized using CERNER and analyzed in Microsoft Excel. Exclusion criteria: Children, age <16. Results: 65 patients had CT scans in which the report stated acute appendicitis. Of those 65 patients, 62 patients underwent diagnostic laparoscopies. 100% of patients who underwent an appendicectomy with a pre-operative CT scan showing acute appendicitis had acute appendicitis in histopathology analysis. 3 of the 65 patients who had a CT scan showing appendicitis received conservative treatment. Conclusion: CT scans positive for acute appendicitis had 100% sensitivity and a positive predictive value, which matches published research studies (sensitivity of 94%). The use of CT scans in the diagnostic work-up for acute appendicitis can be extremely helpful in a) confirming the diagnosis and b) reducing the rates of negative appendicectomies and consequently reducing unnecessary operative-associated risks for patients, reducing costs and reducing pressure on emergency theatre lists.

Keywords: acute apendicitis, CT scan, general surgery, imaging

Procedia PDF Downloads 57
2744 Designing a Cyclic Redundancy Checker-8 for 32 Bit Input Using VHDL

Authors: Ankit Shai

Abstract:

CRC or Cyclic Redundancy Check is one of the most common, and one of the most powerful error-detecting codes implemented on modern computers. Most of the modern communication protocols use some error detection algorithms in digital networks and storage devices to detect accidental changes to raw data between transmission and reception. Cyclic Redundancy Check, or CRC, is the most popular one among these error detection codes. CRC properties are defined by the generator polynomial length and coefficients. The aim of this project is to implement an efficient FPGA based CRC-8 that accepts a 32 bit input, taking into consideration optimal chip area and high performance, using VHDL. The proposed architecture is implemented on Xilinx ISE Simulator. It is designed while keeping in mind the hardware design, complexity and cost factor.

Keywords: cyclic redundancy checker, CRC-8, 32-bit input, FPGA, VHDL, ModelSim, Xilinx

Procedia PDF Downloads 270
2743 Diagnosis of Choledocholithiasis with Endosonography

Authors: A. Kachmazova, A. Shadiev, Y. Teterin, P. Yartcev

Abstract:

Introduction: Biliary calculi disease (LCS) still occupies the leading position among urgent diseases of the abdominal cavity, manifesting itself from asymptomatic course to life-threatening states. Nowadays arsenal of diagnostic methods for choledocholithiasis is quite wide: ultrasound, hepatobiliscintigraphy (HBSG), magnetic resonance imaging (MRI), endoscopic retrograde cholangiography (ERCP). Among them, transabdominal ultrasound (TA ultrasound) is the most accessible and routine diagnostic method. Nowadays ERCG is the "gold" standard in diagnosis and one-stage treatment of biliary tract obstruction. However, transpapillary techniques are accompanied by serious postoperative complications (postmanipulative pancreatitis (3-5%), endoscopic papillosphincterotomy bleeding (2%), cholangitis (1%)), the lethality being 0.4%. GBSG and MRI are also quite informative methods in the diagnosis of choledocholithiasis. Small size of concrements, their localization in intrapancreatic and retroduodenal part of common bile duct significantly reduces informativity of all diagnostic methods described above, that demands additional studying of this problem. Materials and Methods: 890 patients with the diagnosis of cholelithiasis (calculous cholecystitis) were admitted to the Sklifosovsky Scientific Research Institute of Hospital Medicine in the period from August, 2020 to June, 2021. Of them 115 people with mechanical jaundice caused by concrements in bile ducts. Results: Final EUS diagnosis was made in all patients (100,0%). In all patients in whom choledocholithiasis diagnosis was revealed or confirmed after EUS, ERCP was performed urgently (within two days from the moment of its detection) as the X-ray operation room was provided; it confirmed the presence of concrements. All stones were removed by lithoextraction using Dormia basket. The postoperative period in these patients had no complications. Conclusions: EUS is the most informative and safe diagnostic method, which allows to detect choledocholithiasis in patients with discrepancies between clinical-laboratory and instrumental methods of diagnosis in shortest time, that in its turn will help to decide promptly on the further tactics of patient treatment. We consider it reasonable to include EUS in the diagnostic algorithm for choledocholithiasis. Disclosure: Nothing to disclose.

Keywords: endoscopic ultrasonography, choledocholithiasis, common bile duct, concrement, ERCP

Procedia PDF Downloads 64
2742 Studies on Affecting Factors of Wheel Slip and Odometry Error on Real-Time of Wheeled Mobile Robots: A Review

Authors: D. Vidhyaprakash, A. Elango

Abstract:

In real-time applications, wheeled mobile robots are increasingly used and operated in extreme and diverse conditions traversing challenging surfaces such as a pitted, uneven terrain, natural flat, smooth terrain, as well as wet and dry surfaces. In order to accomplish such tasks, it is critical that the motion control functions without wheel slip and odometry error during the navigation of the two-wheeled mobile robot (WMR). Wheel slip and odometry error are disrupting factors on overall WMR performance in the form of deviation from desired trajectory, navigation, travel time and budgeted energy consumption. The wheeled mobile robot’s ability to operate at peak performance on various work surfaces without wheel slippage and odometry error is directly connected to four main parameters, which are the range of payload distribution, speed, wheel diameter, and wheel width. This paper analyses the effects of those parameters on overall performance and is concerned with determining the ideal range of parameters for optimum performance.

Keywords: wheeled mobile robot, terrain, wheel slippage, odometryerror, trajectory

Procedia PDF Downloads 254
2741 Evaluation of Apolipoprotein Profile in HIV/Aids Subjects in Pre and Post 12 Months Antiretroviral Therapy Using 1.5 NG/ML Troponin Diagnostic Cut-off for Myocardial Infarction in Nauth Nnewi, South Eastern Nigeria

Authors: I. P. Ezeugwunne, C. C. Onyenekwe, J. E. Ahaneku, G. I. Ahaneku

Abstract:

Introduction: It has been reported that acute myocardial infarction (AMI) might occur at 1.5 ng/ml troponin level. HIV infection has been documented to influence antiviral drugs, stimulate the production of proteins that enhance fatty acids synthesis. Information on cardiac status in HIV-infected subjects in Nigeria is scanty. Aim: To evaluate the Apolipoprotein profile of HIV subjects in pre-and-post 12 months of antiretroviral therapy (ART) using 1.5 ng/ml troponin diagnostic cut-off for myocardial infarction (MI) in Nnewi, South Eastern, Nigeria. Methodology: A total of 30 symptomatic HIV subjects without malaria co-infection with a mean age of 40.70 ±10.56 years were randomly recruited for this prospective case-controlled study. Serum apolipoproteins (Apo A1, A2, B, C2,C3 and Apo E), troponin and CD4 counts were measured using standard laboratory methods. Parameters were re-classified based on 1.5 ng/ml troponin diagnostic cut-off for MI. Analysis of variance and student paired t-tests were used for data analyses. Results: paired-wise comparison showed that there were significantly higher levels of CD4 counts, Apo A2, Apo C2, Apo E but lower levels of ApoA1, ApoB and ApoC3 in symptomatic HIV subjects before antiretroviral therapy (ART) when compared with after therapy at p<0.05 respectively. The troponin value was significantly higher amongst the group studied at p<0.05, respectively. Conclusion: The increased values of troponin observed among the groups were higher than the diagnostic cut-off for AMI. This may imply that AMI may occur at any group of studies. But the significant reduction in the serum levels of Apo A2, Apo B, Apo C3, Apo E and a significant increase in serum levels of Apo A1, Apo C2 and blood CD4 counts as the length of therapy lengthened may indicate possible cardio-protective effects of the ART on the heart, which may connote recovery.

Keywords: ART, apolipoprotein, HIV, myocardial infarction

Procedia PDF Downloads 130
2740 Malay ESL (English as a Second Language) Students' Difficulties in Using English Prepositions

Authors: Chek Kim Loi

Abstract:

The study attempts to undertake an error analysis of prepositions employed in the written work of Form 4 Malay ESL (English as a Second Language) students in Malaysia. The error analysis is undertaken using Richards’s (1974) framework of intralingual and interlingual errors and Bennett’s (1975) framework in identifying prepositional concepts found in the sample. The study first identifies common prepositional errors in the written texts of 150 student participants. It then measures the relative intensities of these errors and finds out the possible causes for the occurrences of these errors. In this study, one significant finding is that among the nine concepts of prepositions examined, the participant students tended to make errors in the use of prepositions of time and place. The present study has pedagogical implications in teaching English prepositions to Malay ESL students.

Keywords: error, interlingual, intralingual, preposition

Procedia PDF Downloads 172
2739 Coronin 1C and miR-128A as Potential Diagnostic Biomarkers for Glioblastoma Multiform

Authors: Denis Mustafov, Emmanouil Karteris, Maria Braoudaki

Abstract:

Glioblastoma multiform (GBM) is a heterogenous primary brain tumour that kills most affected patients. To the authors best knowledge, despite all research efforts there is no early diagnostic biomarker for GBM. MicroRNAs (miRNAs) are short non-coding RNA molecules which are deregulated in many cancers. The aim of this research was to determine miRNAs with a diagnostic impact and to potentially identify promising therapeutic targets for glioblastoma multiform. In silico analysis was performed to identify deregulated miRNAs with diagnostic relevance for glioblastoma. The expression profiles of the chosen miRNAs were then validated in vitro in the human glioblastoma cell lines A172 and U-87MG. Briefly, RNA extraction was carried out using the Trizol method, whilst miRNA extraction was performed using the mirVANA miRNA isolation kit. Quantitative Real-Time Polymerase Chain Reaction was performed to verify their expression. The presence of five target proteins within the A172 cell line was evaluated by Western blotting. The expression of the CORO1C protein within 32 GBM cases was examined via immunohistochemistry. The miRNAs identified in silico included miR-21-5p, miR-34a and miR-128a. These miRNAs were shown to target deregulated GBM genes, such as CDK6, E2F3, BMI1, JAG1, and CORO1C. miR-34a and miR-128a showed low expression profiles in comparison to a control miR-RNU-44 in both GBM cell lines suggesting tumour suppressor properties. Opposing, miR-21-5p demonstrated greater expression indicating that it could potentially function as an oncomiR. Western blotting revealed expression of all five proteins within the A172 cell line. In silico analysis also suggested that CORO1C is a target of miR-128a and miR-34a. Immunohistochemistry demonstrated that 75% of the GBM cases showed moderate to high expression of CORO1C protein. Greater understanding of the deregulated expression of miR-128a and the upregulation of CORO1C in GBM could potentially lead to the identification of a promising diagnostic biomarker signature for glioblastomas.

Keywords: non-coding RNAs, gene expression, brain tumours, immunohistochemistry

Procedia PDF Downloads 61
2738 The Use of PD and Tanδ Characteristics as Diagnostic Technique for the Insulation Integrity of XLPE Insulated Cable Joints

Authors: Mazen Al-Bulaihed, Nissar Wani, Abdulrahman Al-Arainy, Yasin Khan

Abstract:

Partial Discharge (PD) measurements are widely used for diagnostic purposes in electrical equipment used in power systems. The main cause of these measurements is to prevent large power failures as cables are prone to aging, which usually results in embrittlement, cracking and eventual failure of the insulating and sheathing materials, exposing the conductor and risking a potential short circuit, a likely cause of the electrical fire. Many distribution networks rely heavily on medium voltage (MV) power cables. The presence of joints in these networks is a vital part of serving the consumer demand for electricity continuously. Such measurements become even more important when the extent of dependence increases. Moreover, it is known that the partial discharge in joints and termination are difficult to track and are the most crucial point of failures in large power systems. This paper discusses the diagnostic techniques of four samples of XLPE insulated cable joints, each included with a different type of defect. Experiments were carried out by measuring PD and tanδ at very low frequency applied high voltage. The results show the importance of combining PD and tanδ for effective cable assessment.

Keywords: partial discharge, tan delta, very low frequency, XLPE cable

Procedia PDF Downloads 132
2737 Modified Lot Quality Assurance Sampling (LQAS) Model for Quality Assessment of Malaria Parasite Microscopy and Rapid Diagnostic Tests in Kano, Nigeria

Authors: F. Sarkinfada, Dabo N. Tukur, Abbas A. Muaz, Adamu A. Yahuza

Abstract:

Appropriate Quality Assurance (QA) of parasite-based diagnosis of malaria to justify Artemisinin-based Combination Therapy (ACT) is essential for Malaria Programmes. In Low and Middle Income Countries (LMIC), resource constrain appears to be a major challenge in implementing the conventional QA system. We designed and implemented a modified LQAS model for QA of malaria parasite (MP) microscopy and RDT in a State Specialist Hospital (SSH) and a University Health Clinic (UHC) in Kano, Nigeria. The capacities of both facilities for MP microscopy and RDT were assessed before implementing a modified LQAS over a period of 3 months. Quality indicators comprising the qualities of blood film and staining, MP positivity rates, concordance rates, error rates (in terms of false positives and false negatives), sensitivity and specificity were monitored and evaluated. Seventy one percent (71%) of the basic requirements for malaria microscopy was available in both facilities, with the absence of certifies microscopists, SOPs and Quality Assurance mechanisms. A daily average of 16 to 32 blood samples were tested with a blood film staining quality of >70% recorded in both facilities. Using microscopy, the MP positivity rates were 50.46% and 19.44% in SSH and UHS respectively, while the MP positivity rates were 45.83% and 22.78% in SSH and UHS when RDT was used. Higher concordance rates of 88.90% and 93.98% were recorded in SSH and UHC respectively using microscopy, while lower rates of 74.07% and 80.58% in SSH and UHC were recorded when RDT was used. In both facilities, error rates were higher when RDT was used than with microscopy. Sensitivity and specificity were higher when microscopy was used (95% and 84% in SSH; 94% in UHC) than when RDT was used (72% and 76% in SSH; 78% and 81% in UHC). It could be feasible to implement an integrated QA model for MP microscopy and RDT using modified LQAS in Malaria Control Programmes in Low and Middle Income Countries that might have resource constrain for parasite-base diagnosis of malaria to justify ACT treatment.

Keywords: malaria, microscopy, quality assurance, RDT

Procedia PDF Downloads 200
2736 Tests for Zero Inflation in Count Data with Measurement Error in Covariates

Authors: Man-Yu Wong, Siyu Zhou, Zhiqiang Cao

Abstract:

In quality of life, health service utilization is an important determinant of medical resource expenditures on Colorectal cancer (CRC) care, a better understanding of the increased utilization of health services is essential for optimizing the allocation of healthcare resources to services and thus for enhancing the service quality, especially for high expenditure on CRC care like Hong Kong region. In assessing the association between the health-related quality of life (HRQOL) and health service utilization in patients with colorectal neoplasm, count data models can be used, which account for over dispersion or extra zero counts. In our data, the HRQOL evaluation is a self-reported measure obtained from a questionnaire completed by the patients, misreports and variations in the data are inevitable. Besides, there are more zero counts from the observed number of clinical consultations (observed frequency of zero counts = 206) than those from a Poisson distribution with mean equal to 1.33 (expected frequency of zero counts = 156). This suggests that excess of zero counts may exist. Therefore, we study tests for detecting zero-inflation in models with measurement error in covariates. Method: Under classical measurement error model, the approximate likelihood function for zero-inflation Poisson regression model can be obtained, then Approximate Maximum Likelihood Estimation(AMLE) can be derived accordingly, which is consistent and asymptotically normally distributed. By calculating score function and Fisher information based on AMLE, a score test is proposed to detect zero-inflation effect in ZIP model with measurement error. The proposed test follows asymptotically standard normal distribution under H0, and it is consistent with the test proposed for zero-inflation effect when there is no measurement error. Results: Simulation results show that empirical power of our proposed test is the highest among existing tests for zero-inflation in ZIP model with measurement error. In real data analysis, with or without considering measurement error in covariates, existing tests, and our proposed test all imply H0 should be rejected with P-value less than 0.001, i.e., zero-inflation effect is very significant, ZIP model is superior to Poisson model for analyzing this data. However, if measurement error in covariates is not considered, only one covariate is significant; if measurement error in covariates is considered, only another covariate is significant. Moreover, the direction of coefficient estimations for these two covariates is different in ZIP regression model with or without considering measurement error. Conclusion: In our study, compared to Poisson model, ZIP model should be chosen when assessing the association between condition-specific HRQOL and health service utilization in patients with colorectal neoplasm. and models taking measurement error into account will result in statistically more reliable and precise information.

Keywords: count data, measurement error, score test, zero inflation

Procedia PDF Downloads 263
2735 Forecast Based on an Empirical Probability Function with an Adjusted Error Using Propagation of Error

Authors: Oscar Javier Herrera, Manuel Angel Camacho

Abstract:

This paper addresses a cutting edge method of business demand forecasting, based on an empirical probability function when the historical behavior of the data is random. Additionally, it presents error determination based on the numerical method technique ‘propagation of errors’. The methodology was conducted characterization and process diagnostics demand planning as part of the production management, then new ways to predict its value through techniques of probability and to calculate their mistake investigated, it was tools used numerical methods. All this based on the behavior of the data. This analysis was determined considering the specific business circumstances of a company in the sector of communications, located in the city of Bogota, Colombia. In conclusion, using this application it was possible to obtain the adequate stock of the products required by the company to provide its services, helping the company reduce its service time, increase the client satisfaction rate, reduce stock which has not been in rotation for a long time, code its inventory, and plan reorder points for the replenishment of stock.

Keywords: demand forecasting, empirical distribution, propagation of error, Bogota

Procedia PDF Downloads 598
2734 Assessment of Intern Students' Attitudes towards Medical Errors

Authors: Nilgün Katrancı, Pınar Göv

Abstract:

With the acceleration and assessment of quality and patient safety works in healthcare services in the 21st century, activities to reduce errors have gained importance. The prevention and reduction of unintended consequences related to healthcare services and errors made during the delivery of healthcare services can be achieved by understanding the causes of the errors. Communication is the basic reason most frequently seen in such cases. Nurses who communicate with patients more closely and for longer time play a more critical role in ensuring patient safety compared to other healthcare professionals. To reduce the risk of medical errors and increase the quality of care, it is important to raise the awareness of nurses about patient safety in training period. This descriptive study was conducted between February 2017 and May 2017 to assess intern students' attitudes towards and knowledge of patient safety and medical errors. The target population of the study consists of intern students at the Faculty of Nursing in Gaziantep University (N=180). The study did not apply any sample selection method, and the research group consisted of 90 female and 37 male senior students who were available and accepted to take part in the study (N=127). The study used personal information form and medical error attitude scale to collect data. The medical error attitude scale consists of 16 items and 3 sub-dimensions. The most frequently seen medical error in the clinics the interns worked at was found as ‘Failure to comply with asepsis rules’ with a rate of 67,7%. The most frequent case among reasons for not disclosing an error is ‘noticing and correcting the error before affecting the patient’ with the rate of 70,9%. The most frequently expressed implications of disclosing a serious error for the intern students participating in the study are ‘harming patient trust (78%)’ and ‘possibility of overreaction by patient (62,2%)’. According to the results of the study, the awareness of the students about the importance of medical errors and error reporting was found high (3,48 ± 0,49). Consequently, it is important to assess and positively improve the attitudes of nurses and other healthcare professionals towards medical errors for the determination of causes of medical errors and their prevention.

Keywords: healthcare service, intern student, medical error, patient safety

Procedia PDF Downloads 180
2733 Development of a Pain Detector Using Microwave Radiometry Method

Authors: Nanditha Rajamani, Anirudhaa R. Rao, Divya Sriram

Abstract:

One of the greatest difficulties in treating patients with pain is the highly subjective nature of pain sensation. The measurement of pain intensity is primarily dependent on the patient’s report, often with little physical evidence to provide objective corroboration. This is also complicated by the fact that there are only few and expensive existing technologies (Functional Magnetic Resonance Imaging-fMRI). The need is thus clear and urgent for a reliable, non-invasive, non-painful, objective, readily adoptable, and coefficient diagnostic platform that provides additional diagnostic information to supplement its current regime with more information to assist doctors in diagnosing these patients. Thus, our idea of developing a pain detector was conceived to take a step further the detection and diagnosis of chronic and acute pain.

Keywords: pain sensor, microwave radiometery, pain sensation, fMRI

Procedia PDF Downloads 426
2732 Dynamic Compensation for Environmental Temperature Variation in the Coolant Refrigeration Cycle as a Means of Increasing Machine-Tool Precision

Authors: Robbie C. Murchison, Ibrahim Küçükdemiral, Andrew Cowell

Abstract:

Thermal effects are the largest source of dimensional error in precision machining, and a major proportion is caused by ambient temperature variation. The use of coolant is a primary means of mitigating these effects, but there has been limited work on coolant temperature control. This research critically explored whether CNC-machine coolant refrigeration systems adapted to actively compensate for ambient temperature variation could increase machining accuracy. Accuracy data were collected from operators’ checklists for a CNC 5-axis mill and statistically reduced to bias and precision metrics for observations of one day over a sample period of 27 days. Temperature data were collected using three USB dataloggers in ambient air, the chiller inflow, and the chiller outflow. The accuracy and temperature data were analysed using Pearson correlation, then the thermodynamics of the system were described using system identification with MATLAB. It was found that 75% of thermal error is reflected in the hot coolant temperature but that this is negligibly dependent on ambient temperature. The effect of the coolant refrigeration process on hot coolant outflow temperature was also found to be negligible. Therefore, the evidence indicated that it would not be beneficial to adapt coolant chillers to compensate for ambient temperature variation. However, it is concluded that hot coolant outflow temperature is a robust and accessible source of thermal error data which could be used for prevention strategy evaluation or as the basis of other thermal error strategies.

Keywords: CNC manufacturing, machine-tool, precision machining, thermal error

Procedia PDF Downloads 61
2731 Modelling Volatility of Cryptocurrencies: Evidence from GARCH Family of Models with Skewed Error Innovation Distributions

Authors: Timothy Kayode Samson, Adedoyin Isola Lawal

Abstract:

The past five years have shown a sharp increase in public interest in the crypto market, with its market capitalization growing from $100 billion in June 2017 to $2158.42 billion on April 5, 2022. Despite the outrageous nature of the volatility of cryptocurrencies, the use of skewed error innovation distributions in modelling the volatility behaviour of these digital currencies has not been given much research attention. Hence, this study models the volatility of 5 largest cryptocurrencies by market capitalization (Bitcoin, Ethereum, Tether, Binance coin, and USD Coin) using four variants of GARCH models (GJR-GARCH, sGARCH, EGARCH, and APARCH) estimated using three skewed error innovation distributions (skewed normal, skewed student- t and skewed generalized error innovation distributions). Daily closing prices of these currencies were obtained from Yahoo Finance website. Finding reveals that the Binance coin reported higher mean returns compared to other digital currencies, while the skewness indicates that the Binance coin, Tether, and USD coin increased more than they decreased in values within the period of study. For both Bitcoin and Ethereum, negative skewness was obtained, meaning that within the period of study, the returns of these currencies decreased more than they increased in value. Returns from these cryptocurrencies were found to be stationary but not normality distributed with evidence of the ARCH effect. The skewness parameters in all best forecasting models were all significant (p<.05), justifying of use of skewed error innovation distributions with a fatter tail than normal, Student-t, and generalized error innovation distributions. For Binance coin, EGARCH-sstd outperformed other volatility models, while for Bitcoin, Ethereum, Tether, and USD coin, the best forecasting models were EGARCH-sstd, APARCH-sstd, EGARCH-sged, and GJR-GARCH-sstd, respectively. This suggests the superiority of skewed Student t- distribution and skewed generalized error distribution over the skewed normal distribution.

Keywords: skewed generalized error distribution, skewed normal distribution, skewed student t- distribution, APARCH, EGARCH, sGARCH, GJR-GARCH

Procedia PDF Downloads 71
2730 On Constructing a Cubically Convergent Numerical Method for Multiple Roots

Authors: Young Hee Geum

Abstract:

We propose the numerical method defined by xn+1 = xn − λ[f(xn − μh(xn))/]f'(xn) , n ∈ N, and determine the control parameter λ and μ to converge cubically. In addition, we derive the asymptotic error constant. Applying this proposed scheme to various test functions, numerical results show a good agreement with the theory analyzed in this paper and are proven using Mathematica with its high-precision computability.

Keywords: asymptotic error constant, iterative method, multiple root, root-finding

Procedia PDF Downloads 196
2729 SSRUIC Students’ Attitude and Preference toward Error Corrections

Authors: Papitchaya Papangkorn

Abstract:

Matching the expectations of teachers and learners is significant for successful language learning. Moreover, teachers should discover what their learners think and feel about what and how they want to learn. Therefore, this study investigates International College, Suan Sunandha Rajabhat University students’ preferences toward error corrections in order to help SSRUIC teachers match their expectations and their learners because it is important for successful language learning. This study examined the learners’ attitude and preference toward error correction through 50 first year SSRUIC students both male (25) and female (25) in Bangkok, Thailand. The data were collected from a questionnaire and interviews to investigate the necessity and frequency, timing, type of errors, method of corrective feedback, and person who gives error correction in order to answer the overall research question and sub-questions. The findings indicate five suggestions regarding the overall research question. Firstly, errors should be treated, and always be treated. Secondly, treating errors after finish speaking is the most appropriate time. Thirdly, “errors that may cause problems in an understanding of listener” and “frequent spoken errors” should be treated. Fourthly, repetition and explicit feedback were the most popular types of feedback among males, whereas metalinguistic feedback was the most favoured types amongst females. Finally, teachers were the most preferred person to deliver corrective feedback for the learners. Although the results of the study are difficult to generalize to a larger population, which are Thai EFL learners because of the small sample, the findings provide useful information that may contribute to understanding of SSRUIC learners’ preferences toward error corrections and it might reduce the gap between what teachers employ and what students expect when receiving corrective feedback. The reduction of this gap may be useful for the learning process and could enhance the efforts of both teachers and learners in a Thai context.

Keywords: attitude, corrective feedback, error, preference

Procedia PDF Downloads 343
2728 Channel Estimation for LTE Downlink

Authors: Rashi Jain

Abstract:

The LTE systems employ Orthogonal Frequency Division Multiplexing (OFDM) as the multiple access technology for the Downlink channels. For enhanced performance, accurate channel estimation is required. Various algorithms such as Least Squares (LS), Minimum Mean Square Error (MMSE) and Recursive Least Squares (RLS) can be employed for the purpose. The paper proposes channel estimation algorithm based on Kalman Filter for LTE-Downlink system. Using the frequency domain pilots, the initial channel response is obtained using the LS criterion. Then Kalman Filter is employed to track the channel variations in time-domain. To suppress the noise within a symbol, threshold processing is employed. The paper draws comparison between the LS, MMSE, RLS and Kalman filter for channel estimation. The parameters for evaluation are Bit Error Rate (BER), Mean Square Error (MSE) and run-time.

Keywords: LTE, channel estimation, OFDM, RLS, Kalman filter, threshold

Procedia PDF Downloads 334
2727 Evaluating the Implementation of a Quality Management System in the COVID-19 Diagnostic Laboratory of a Tertiary Care Hospital in Delhi

Authors: Sukriti Sabharwal, Sonali Bhattar, Shikhar Saxena

Abstract:

Introduction: COVID-19 molecular diagnostic laboratory is the cornerstone of the COVID-19 disease diagnosis as the patient’s treatment and management protocol depend on the molecular results. For this purpose, it is extremely important that the laboratory conducting these results adheres to the quality management processes to increase the accuracy and validity of the reports generated. We started our own molecular diagnostic setup at the onset of the pandemic. Therefore, we conducted this study to generate our quality management data to help us in improving on our weak points. Materials and Methods: A total of 14561 samples were evaluated by the retrospective observational method. The quality variables analysed were classified into pre-analytical, analytical, and post-analytical variables, and the results were presented in percentages. Results: Among the pre-analytical variables, sample leaking was the most common cause of the rejection of samples (134/14561, 0.92%), followed by non-generation of SRF ID (76/14561, 0.52%) and non-compliance to triple packaging (44/14561, 0.3%). The other pre-analytical aspects assessed were incomplete patient identification (17/14561, 0.11%), insufficient quantity of samples (12/14561, 0.08%), missing forms/samples (7/14561, 0.04%), samples in the wrong vials/empty VTM tubes (5/14561, 0.03%) and LIMS entry not done (2/14561, 0.01%). We are unable to obtain internal quality control in 0.37% of samples (55/14561). We also experienced two incidences of cross-contamination among the samples resulting in false-positive results. Among the post-analytical factors, a total of 0.07% of samples (11/14561) could not be dispatched within the stipulated time frame. Conclusion: Adherence to quality control processes is foremost for the smooth running of any diagnostic laboratory, especially the ones involved in critical reporting. Not only do the indicators help in keeping in check the laboratory parameters but they also allow comparison with other laboratories.

Keywords: laboratory quality management, COVID-19, molecular diagnostics, healthcare

Procedia PDF Downloads 130
2726 Usability Evaluation of Rice Doctor as a Diagnostic Tool for Agricultural Extension Workers in Selected Areas in the Philippines

Authors: Jerome Cayton Barradas, Rowely Parico, Lauro Atienza, Poornima Shankar

Abstract:

The effective agricultural extension is essential in facilitating improvements in various agricultural areas. One way of doing this is through Information and communication technologies (ICTs) like Rice Doctor (RD), an app-based diagnostic tool that provides accurate and timely diagnosis and management recommendations for more than 80 crop problems. This study aims to evaluate the RD usability by determining the effectiveness, efficiency, and user satisfaction of RD in making an accurate and timely diagnosis. It also aims to identify other factors that affect RD usability. This will be done by comparing RD with two other diagnostic methods: visual identification-based diagnosis and reference-guided diagnosis. The study was implemented in three rice-producing areas and has involved 96 extension workers. Respondents accomplished a self-administered survey and participated in group discussions. Data collected was then subjected to qualitative and quantitative analysis. Most of the respondents were satisfied with RD and believed that references are needed in assuring the accuracy of diagnosis. The majority found it efficient and easy to use. Some found it confusing and complicated, but this is because of their unfamiliarity with RD. Most users were also able to achieve accurate diagnosis proving effectiveness. Lastly, although users have reservations, they are satisfied and open to using RD. The study also found out the importance of visual identification skills in using RD and the need for capacity development and improvement of access to RD devices. From these results, the following are recommended to improve RD usability: review and upgrade diagnostic keys, expand further RD content, initiate capacity development for AEWs, and prepare and implement an RD communication plan.

Keywords: agricultural extension, crop protection, information and communication technologies, rice doctor

Procedia PDF Downloads 230
2725 A Novel Approach to Design of EDDR Architecture for High Speed Motion Estimation Testing Applications

Authors: T. Gangadhararao, K. Krishna Kishore

Abstract:

Motion Estimation (ME) plays a critical role in a video coder, testing such a module is of priority concern. While focusing on the testing of ME in a video coding system, this work presents an error detection and data recovery (EDDR) design, based on the residue-and-quotient (RQ) code, to embed into ME for video coding testing applications. An error in processing Elements (PEs), i.e. key components of a ME, can be detected and recovered effectively by using the proposed EDDR design. The proposed EDDR design for ME testing can detect errors and recover data with an acceptable area overhead and timing penalty.

Keywords: area overhead, data recovery, error detection, motion estimation, reliability, residue-and-quotient (RQ) code

Procedia PDF Downloads 405
2724 Uncertainty Quantification of Corrosion Anomaly Length of Oil and Gas Steel Pipelines Based on Inline Inspection and Field Data

Authors: Tammeen Siraj, Wenxing Zhou, Terry Huang, Mohammad Al-Amin

Abstract:

The high resolution inline inspection (ILI) tool is used extensively in the pipeline industry to identify, locate, and measure metal-loss corrosion anomalies on buried oil and gas steel pipelines. Corrosion anomalies may occur singly (i.e. individual anomalies) or as clusters (i.e. a colony of corrosion anomalies). Although the ILI technology has advanced immensely, there are measurement errors associated with the sizes of corrosion anomalies reported by ILI tools due limitations of the tools and associated sizing algorithms, and detection threshold of the tools (i.e. the minimum detectable feature dimension). Quantifying the measurement error in the ILI data is crucial for corrosion management and developing maintenance strategies that satisfy the safety and economic constraints. Studies on the measurement error associated with the length of the corrosion anomalies (in the longitudinal direction of the pipeline) has been scarcely reported in the literature and will be investigated in the present study. Limitations in the ILI tool and clustering process can sometimes cause clustering error, which is defined as the error introduced during the clustering process by including or excluding a single or group of anomalies in or from a cluster. Clustering error has been found to be one of the biggest contributory factors for relatively high uncertainties associated with ILI reported anomaly length. As such, this study focuses on developing a consistent and comprehensive framework to quantify the measurement errors in the ILI-reported anomaly length by comparing the ILI data and corresponding field measurements for individual and clustered corrosion anomalies. The analysis carried out in this study is based on the ILI and field measurement data for a set of anomalies collected from two segments of a buried natural gas pipeline currently in service in Alberta, Canada. Data analyses showed that the measurement error associated with the ILI-reported length of the anomalies without clustering error, denoted as Type I anomalies is markedly less than that for anomalies with clustering error, denoted as Type II anomalies. A methodology employing data mining techniques is further proposed to classify the Type I and Type II anomalies based on the ILI-reported corrosion anomaly information.

Keywords: clustered corrosion anomaly, corrosion anomaly assessment, corrosion anomaly length, individual corrosion anomaly, metal-loss corrosion, oil and gas steel pipeline

Procedia PDF Downloads 286
2723 An Error Analysis of English Communication of Suan Sunandha Rajabhat University Students

Authors: Chantima Wangsomchok

Abstract:

The main purposes of this study are (1) to test the students’ communicative competence within six main functions: greeting, parting, thanking, offering, requesting and suggesting, (2) to employ error analysis in the students’ communicative competence within those functions, and (3) to compare the characteristics of the error found from the investigation. The subjects of the study is 328 first-year undergraduates taking the Foundation English course in the first semester of the 2008 academic year at Suan Sunandha Rajabhat University. This study found that while the subjects showed high communicative competence in the use of the following three functions: greeting, thanking, and offering, they seemed to show poor communicative competence in suggesting, requesting and parting instead. In addition, this study found that the grammatical errors were likely to be most frequently found in the parting function. In the same way, the type of errors which were less frequently found was in the functions of thanking and requesting respectively. Instead, the students tended to have high pragmatic failure in the use of greeting and suggesting functions.

Keywords: error analysis, functions of English language, communicative competence, cognitive science

Procedia PDF Downloads 404
2722 Development of Elementary Literacy in the Czech Republic

Authors: Iva Košek Bartošová

Abstract:

There is great attention being paid in the field of development of first reading, thus early literacy skills in the Czech Republic. Yet inconclusive results of PISA and PIRLS force us to think over the teacher´s work, his/her roles in the education process and methods and forms used in lessons. There is also a significant importance to monitor the family environment and the pupil, themselves. The aim of the publishing output is to focus on one side dealing with methods of practicing reading technique and their results in the process of comprehension. In the first part of the contribution there are the goals of development of reading literacy and the methods used in reading practice in some EU countries and a follow-up comparison of research implemented by the help of modern technology of an eye tracker device in the year 2015 and a research conducted at the Institute of Education and Psychological Counselling of the Czech Republic in the year 2011/12. These are the results of a diagnostic test of reading in first classes of primary schools, taught by the genetic method and analytic-synthetic method. The results show that in the first stage of practice there are no statistically significant differences between any researched subjects taught by different methods of reading practice (with the use of several diagnostic texts focused on reading technique and its comprehension). Different results are shown at the end of Grade One and during Grade Two of primary school.

Keywords: elementary literacy, eye tracker device, diagnostic reading tests, reading teaching method

Procedia PDF Downloads 166
2721 Exploring Bidirectional Encoder Representations from the Transformers’ Capabilities to Detect English Preposition Errors

Authors: Dylan Elliott, Katya Pertsova

Abstract:

Preposition errors are some of the most common errors created by L2 speakers. In addition, improving error correction and detection methods remains an open issue in the realm of Natural Language Processing (NLP). This research investigates whether the bidirectional encoder representations from the transformers model (BERT) have the potential to correct preposition errors accurately enough to be useful in error correction software. This research finds that BERT performs strongly when the scope of its error correction is limited to preposition choice. The researchers used an open-source BERT model and over three hundred thousand edited sentences from Wikipedia, tagged for part of speech, where only a preposition edit had occurred. To test BERT’s ability to detect errors, a technique known as multi-level masking was used to generate suggestions based on sentence context for every prepositional environment in the test data. These suggestions were compared with the original errors in the data and their known corrections to evaluate BERT’s performance. The suggestions were further analyzed to determine if BERT more often agreed with the judgements of the Wikipedia editors. Both the untrained and fined-tuned models were compared. Finetuning led to a greater rate of error-detection which significantly improved recall, but lowered precision due to an increase in false positives or falsely flagged errors. However, in most cases, these false positives were not errors in preposition usage but merely cases where more than one preposition was possible. Furthermore, when BERT correctly identified an error, the model largely agreed with the Wikipedia editors, suggesting that BERT’s ability to detect misused prepositions is better than previously believed. To evaluate to what extent BERT’s false positives were grammatical suggestions, we plan to do a further crowd-sourcing study to test the grammaticality of BERT’s suggested sentence corrections against native speakers’ judgments.

Keywords: BERT, grammatical error correction, preposition error detection, prepositions

Procedia PDF Downloads 120
2720 Urinary Neutrophil Gelatinase Associated Lipocalin as Diagnostic Biomarkers for Lupus Nephritis

Authors: Lorena GóMez Escorcia, Gustavo Aroca MartíNez, Jose Luiz Villarreal, Elkin Navarro Quiroz

Abstract:

Lupus nephritis (LN) is a high-cost disease, occurring in about half of patients with Systemic Lupus Erythematosus (SLE). Renal biopsy constitutes the only protocol that, to date, allows a correct diagnosis of the level of renal involvement in these patients. However, this procedure can have various adverse effects such as kidney bleeding, muscle bleeding, infection, pain, among others. Therefore, the development of new diagnostic alternatives is required. The neutrophil gelatinase-associated lipocalin (NGAL) has been emerging as a novel biomarker of acute kidney injury. The aim of this study was to assess urinary NGAL levels as a marker for disease activity in patients with lupus nephritis. For this work included 50 systemic lupus erythematosus (SLE) patients, 50 with active lupus nephritis (LN), and 50 without autoimmune and renal disease as controls. TNGAL in urine samples was measured by enzyme-linked immunosorbent assay (ELISA). The results revealed that patients with kidney damage had an elevated urinary NGAL as compared to patients with lupus without kidney damage and controls (p <0.005), and the mean of uNGAL was (28.72 ± 4.53), (19.51 ± 4.72), (8.91 ± 3.37) respectively. Measurement of urinary NGAL levels showed a very good diagnostic performance for discriminating patients with Lupus nephritis from SLE without renal damage and of control individuals.

Keywords: lupus nephritis, biomarker, NGAL, urine samples

Procedia PDF Downloads 184
2719 The Influence of Students’ Race and Socioeconomic Status on Teachers’ Assessment of ADHD: Implications for Educational Inequalities

Authors: Justine McKay

Abstract:

Implicit Bias and its impact on the schooling experience of racial minorities with ADHD is significant. ADHD has become a globally diagnosed disorder. The lack of an objective diagnostic tool for ADHD has created controversy over the disease and its validity. ADHD is referred to as a social construct or a suburban problem related to active white boys who disrupt classrooms. The subjectivity of an ADHD diagnosis and the diagnostic process is based on norm-referenced checklists of behaviours completed by the student, caregiver, teachers, clinicians, and other community members. Teachers' perceptions of classroom behaviours are influenced by implicit bias related to race and socioeconomic status. The same behaviours displayed by white and marginalized or low-income students are perceived differently. The white student is perceived to be struggling academically and needing support, while the marginalized or lower-income student's behaviour is seen as disruptive or criminal. The presence of teacher implicit bias results in the inequity of diagnosis, and academic support, which has long-term implications for these students. The subjectivity of the diagnostic process socially reproduces the systemic injustice of opportunity for marginalized youth within the education system.

Keywords: ADHD, education, equity, implicit bias, subjectivity

Procedia PDF Downloads 51