Search results for: inappropriate installation
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 791

Search results for: inappropriate installation

251 Environmental Justice and Citizenship Rights in the Tehran Health Plan

Authors: Mohammad Parvaresh, Mahdi Babaee, Bahareh Arghand, Davood Nourmohammadi

Abstract:

Environmental degradation is caused by social inequalities and the inappropriate use of nature and a factor in the violation of human rights. Indeed, the right to a safe, healthy and ecologically-balanced environment is an independent human right. Therefore, the relationship between human rights and environmental protection is crucial for the study of social justice and sustainable development, and environmental problems are a result of the failure to realize social and economic justice. In this regard, 'article 50 of the constitution of the Islamic Republic of Iran as a general principle have many of the concepts of sustainable development, including: the growth and improvement of human life, the rights of present and future generations, and the integrity of the inner and outer generation, the prohibition of any environmental degradation'. Also, Charter on Citizen’s Rights, which was conveyed by the President of the Islamic Republic of Iran, Mr. Rouhani refers to the right to a healthy environment and sustainable development. In this regard in 2013, Tehran Province Water and Wastewater Co. defined a plan called 'Tehran’s Health Line' was includes Western and Eastern part by about 26 kilometers of water transferring pipelines varied 1000 to 2000 mm diameters. This project aims to: (1) Transfer water from the northwest water treatment plant to the southwest areas, which suffer from qualitative and quantitative water, in order to mix with the improper wells’ water; (2) Reducing the water consumption provided by harvesting from wells which results in improving the underground water resources, causing the large settlements and stopping the immigrating slums into the center or north side of the city. All of the financial resources accounted for 53,000,000 US$ which is mobilized by Tehran Province Water and Wastewater Co. to expedite the work. The present study examines the Tehran Health Line plan and the purpose of implementation of this plan to achieve environmental protection, environmental justice and citizenship rights for all people who live in Tehran.

Keywords: environmental justice, international environmental law, erga omnes, charter on citizen's rights, Tehran health line

Procedia PDF Downloads 268
250 Energy Consumption Estimation for Hybrid Marine Power Systems: Comparing Modeling Methodologies

Authors: Kamyar Maleki Bagherabadi, Torstein Aarseth Bø, Truls Flatberg, Olve Mo

Abstract:

Hydrogen fuel cells and batteries are one of the promising solutions aligned with carbon emission reduction goals for the marine sector. However, the higher installation and operation costs of hydrogen-based systems compared to conventional diesel gensets raise questions about the appropriate hydrogen tank size, energy, and fuel consumption estimations. Ship designers need methodologies and tools to calculate energy and fuel consumption for different component sizes to facilitate decision-making regarding feasibility and performance for retrofits and design cases. The aim of this work is to compare three alternative modeling approaches for the estimation of energy and fuel consumption with various hydrogen tank sizes, battery capacities, and load-sharing strategies. A fishery vessel is selected as an example, using logged load demand data over a year of operations. The modeled power system consists of a PEM fuel cell, a diesel genset, and a battery. The methodologies used are: first, an energy-based model; second, considering load variations during the time domain with a rule-based Power Management System (PMS); and third, a load variations model and dynamic PMS strategy based on optimization with perfect foresight. The errors and potentials of the methods are discussed, and design sensitivity studies for this case are conducted. The results show that the energy-based method can estimate fuel and energy consumption with acceptable accuracy. However, models that consider time variation of the load provide more realistic estimations of energy and fuel consumption regarding hydrogen tank and battery size, still within low computational time.

Keywords: fuel cell, battery, hydrogen, hybrid power system, power management system

Procedia PDF Downloads 29
249 Ironic Historiography: On Art, Nationality and In-Between Identities

Authors: Sigal Barkai

Abstract:

'Ironic Historiography' is a hybrid notion combining criticism of historical narratives concerning the Israeli state with ironic artistic expression. The paper will deal with questions of identities of native Israeli visual artists who chose to live out of the country, or to move back and forth to and from it. It will examine the ways these wanderings are reflected in their work. The paper discusses the work of 4 contemporary artists who produce artworks in diverse techniques and media, such as video, performance and installation art. Yael Bartana, Erez Israeli and Tamir Zadok are artists who constantly deal with Israeli nationality and history in their artwork, using ironic components. In comparison, the paper will review the works of Mika Rottenberg, who is now a New York based artist. She is concerned with global social issues and neglected specific national identity altogether. All of them use visual irony as a means of reflecting and criticizing society. The analysis was done in awareness of the life stories of the artists, in an attempt to trace the ways they establish their identities through their art. It was pre-supposed that these identities will be shaped in the in-between space of being an Israeli citizen and a citizen of the world. The study asks how ironic expression appears in their work, what kind of irony do they use and in what ways does it serves them. The methodology combined visual analysis, interviews with the artists, and analyzation of secondary discourses in the media. As theoretical background various fields of knowledge were used, such as literature and language studies, Sociology, and Visual Culture studies. The findings point out that visual and artistic irony has many different goals in the use of historiographic fiction. It can bind an artist to his homeland and native society, or it can help her to detach. It helps healing breaches in the in-between space, or it can be used as a means to completely detach from any identification with a native origin.

Keywords: visual art, irony, identities, Israel

Procedia PDF Downloads 249
248 Morphological Variation of the Mesenteric Lymph Node in Dromedary Camels: The Impact of Rearing Systems

Authors: Khenenou Tarek, Mohamed Amine Fares, Djallal Eddine Rahmoun

Abstract:

The study intends to evaluate the morphological changes in the mesenteric lymph nodes of dromedaries in different rearing systems. we aimed to evaluate the adaptative behavior of the animal’s immune system with environmental variations, and to conduct a comparative analysis on the morphological features of the mesenteric lymph node of the one-humped camel (Camelus dromedarius) in the region of El Oued, with two different rearing systems, with different practices and different purposes. The study was conducted using histo-morphometric techniques to analyze the morphological features of the mesenteric lymph node of the one-humped camel (Camelus dromedarius) in the region of El Oued. Two groups of dromedaries were used in the study, one group raised in a free-roaming housing system and another group raised in a restricted-roaming housing system. The results revealed that there were significant differences between the two groups in terms of active follicle ratio and size and also the cellular population of functional zones. Animals living and roaming outside the farm barriers were more exposed to pathogens, which leads to the installation of an adaptative process, whereas the animals living under restricted-roaming housing system were not exposed to pathogens. This study indicated that the adaptative behavior of the animal’s immune system with environmental variations is the functional translation of morphological changes. The obtained findings revealed that the morphological features of the mesenteric lymph node of the one-humped camel (Camelus dromedarius) in the region of El Oued are directly linked to the rearing system practices

Keywords: adaptative behavior, dromedary, lymph node, morphology, rearing systems

Procedia PDF Downloads 14
247 Hybrid Renewable Power Systems

Authors: Salman Al-Alyani

Abstract:

In line with the Kingdom’s Vision 2030, the Saudi Green initiative was announced aimed at reducing carbon emissions by more than 4% of the global contribution. The initiative included plans to generate 50% of its energy from renewables by 2030. The geographical location of Saudi Arabia makes it among the best countries in terms of solar irradiation and has good wind resources in many areas across the Kingdom. Saudi Arabia is a wide country and has many remote locations where it is not economically feasible to connect those loads to the national grid. With the improvement of battery innovation and reduction in cost, different renewable technologies (primarily wind and solar) can be integrated to meet the need for energy in a more effective and cost-effective way. Saudi Arabia is famous for high solar irradiations in which solar power generation can extend up to six (6) hours per day (25% capacity factor) in some locations. However, the net present value (NPV) falls down to negative in some locations due to distance and high installation costs. Wind generation in Saudi Arabia is a promising technology. Hybrid renewable generation will increase the net present value and lower the payback time due to additional energy generated by wind. The infrastructure of the power system can be capitalized to contain solar generation and wind generation feeding the inverter, controller, and load. Storage systems can be added to support the hours that have an absence of wind or solar energy. Also, the smart controller that can help integrate various renewable technologies primarily wind and solar, to meet demand considering load characteristics. It could be scalable for grid or off-grid applications. The objective of this paper is to study the feasibility of introducing a hybrid renewable system in remote locations and the concept for the development of a smart controller.

Keywords: battery storage systems, hybrid power generation, solar energy, wind energy

Procedia PDF Downloads 176
246 Empirical Analysis of the Effect of Cloud Movement in a Basic Off-Grid Photovoltaic System: Case Study Using Transient Response of DC-DC Converters

Authors: Asowata Osamede, Christo Pienaar, Johan Bekker

Abstract:

Mismatch in electrical energy (power) or outage from commercial providers, in general, does not promote development to the public and private sector, these basically limit the development of industries. The necessity for a well-structured photovoltaic (PV) system is of importance for an efficient and cost-effective monitoring system. The major renewable energy potential on earth is provided from solar radiation and solar photovoltaics (PV) are considered a promising technological solution to support the global transformation to a low-carbon economy and reduction on the dependence on fossil fuels. Solar arrays which consist of various PV module should be operated at the maximum power point in order to reduce the overall cost of the system. So power regulation and conditioning circuits should be incorporated in the set-up of a PV system. Power regulation circuits used in PV systems include maximum power point trackers, DC-DC converters and solar chargers. Inappropriate choice of power conditioning device in a basic off-grid PV system can attribute to power loss, hence the need for a right choice of power conditioning device to be coupled with the system of the essence. This paper presents the design and implementation of a power conditioning devices in order to improve the overall yield from the availability of solar energy and the system’s total efficiency. The power conditioning devices taken into consideration in the project includes the Buck and Boost DC-DC converters as well as solar chargers with MPPT. A logging interface circuit (LIC) is designed and employed into the system. The LIC is designed on a printed circuit board. It basically has DC current signalling sensors, specifically the LTS 6-NP. The LIC is consequently required to program the voltages in the system (these include the PV voltage and the power conditioning device voltage). The voltage is structured in such a way that it can be accommodated by the data logger. Preliminary results which include availability of power as well as power loss in the system and efficiency will be presented and this would be used to draw the final conclusion.

Keywords: tilt and orientation angles, solar chargers, PV panels, storage devices, direct solar radiation

Procedia PDF Downloads 133
245 Experience of Continuous Ambulatory Peritoneal Dialysis in Remote Area of Southeast Bangladesh

Authors: Rafiqul Hasan, A. S. M. Tanim Anwar, Mohammad Azizul Hakim

Abstract:

Background: Chronic kidney disease (CKD) is a major public health problem that continues to increase in prevalence globally. The prevalence of chronic kidney disease is increasing day by day in low to middle income countries (LMICs). People living in LMICs have the highest need for renal replacement therapy (RRT) despite they have lowest access to various modalities of treatment. As continuous ambulatory peritoneal dialysis (CAPD) does not require advanced technologies, very much infrastructure, dialysis staff support, it should be an ideal form of RRT in LMICs, particularly for those living in remote areas. To authors knowledge there was scarcity of data regarding CAPD performance in remote area of Bangladesh. This study was aimed to report the characteristics and outcomes of CAPD in ESRD patients lived in least developed area of Bangladesh. Methods: This prospective study was conducted in Cox’sbazar Medical College Hospital, Cox’sbazar and Parkview hospital Ltd, Chattogram, Bangladesh. Data were collected by questionnaire from the patients of any age with end-stage renal disease (ESRD) who underwent CAPD in 2018–2021. The baseline characteristics, PD-related complication as well as patient and technique survivals were analyzed. Results: Out of 31 patients who underwent CAPD, 18 (58%) were male on the age range of 15–79 years. The mean follow-up duration was 18 months. Mortality was inversely related with the EF of echocardiography. The peritonitis rate was 0.48 episodes per patient per year. The 1, 3 and 4-year patient survival rates were 64.34% (95% CI = 52.5–81.5), 23.79% (95% CI = 17.9 – 57.4) and 3.22% (95% CI = 31.2–77.5) respectively. Conclusions: In this study, CAPD performance was poorer than usual reference. Cardiac compromised patient and inappropriate dwell might be the main contributing factors behind this scenario. The peritonitis rate was nearly similar to that of developed countries. CAPD was cost effective than HD in remote area. Some accessible measures may be taken to make CAPD a more acceptable RRT modality with improved outcomes in poor socioeconomic backgrounds.

Keywords: dialysis cost, peritoneal dialysis, peritonitis, CAPD, least developed area, remote area, Bangladesh

Procedia PDF Downloads 57
244 Medication Errors in Neonatal Intensive Care Unit

Authors: Ramzi Shawahna

Abstract:

Background: Neonatal intensive care units are high-risk settings where medication errors can occur and cause harm to this fragile segment of patients. This multicenter qualitative study was conducted to describe medication errors that occurred in neonatal intensive care units in Palestine from the perspectives of healthcare providers. Methods: This exploratory multicenter qualitative study was conducted and reported in adherence to the consolidated criteria for reporting qualitative research checklist. Semi-structured in-depth interviews were conducted with healthcare professionals (4 pediatricians/neonatologists and 11 intensive care unit nurses) who provided care services for patients admitted to neonatal intensive care units in Palestine. An interview schedule guided the semi-structured in-depth interviews. The qualitative interpretive description approach was used to thematically analyze the data. Results: The total duration of the interviews was 282 min. The healthcare providers described their experiences with 41 different medication errors. These medication errors were categorized under 3 categories and 10 subcategories. Errors that occurred while preparing/diluting/storing medications were related to calculations, using a wrong solvent/diluent, dilution errors, failure to adhere to guidelines while preparing the medication, failure to adhere to storage/packaging guidelines, and failure to adhere to labeling guidelines. Errors that occurred while prescribing/administering medications were related to inappropriate medication for the neonate, using a different administration technique from the one that was intended and administering a different dose from the one that was intended. Errors that occurred after administering the medications were related to failure to adhere to monitoring guidelines. Conclusion: In this multicenter study, pediatricians/neonatologists and neonatal intensive care unit nurses described medication errors occurring in intensive care units in Palestine. Medication errors occur in different stages of the medication process: preparation/dilution/storage, prescription/administration, and monitoring. Further studies are still needed to quantify medication errors occurring in neonatal intensive care units and investigate if the designed strategies could be effective in minimizing medication errors.

Keywords: medication errors, pharmacist, pharmacology, neonates

Procedia PDF Downloads 76
243 Typification and Determination of Antibiotic Resistance Rates of Stenotrophomonas Maltophilia Strains Isolated from Intensive Care Unit Patients in a University Practice and Research Hospital

Authors: Recep Kesli, Gulsah Asik, Cengiz Demir, Onur Turkyilmaz

Abstract:

Objective: Stenotrophomonas maltophilia (S. maltophilia) has recently emerged as an important nosocomial microorganism. Treatment of invasive infections caused by this organism is problematic because this microorganism is usually resistant to a wide range of commonly used antimicrobials. We aimed to evaluate clinical isolates of S. maltophilia in respect to sampling sites and antimicrobial resistant. Method: During a two years period (October 2013 and September 2015) eighteen samples collected from the intensive care unit (ICU) patients hospitalized in Afyon Kocatepe University, ANS Practice and Research Hospital. Identification of the bacteria was determined by conventional methods and automated identification system-VITEK 2 (bio-Mérieux, Marcy l’toile, France). Antibacterial resistance tests were performed by Kirby Bauer disc (Oxoid, England) diffusion method following the recommendations of CLSI. Results: Eighteen S. maltophilia strains were identified as the causative agents of different infections. The main type of infection was lower respiratory tract infection (83,4 %); three patients (16,6 %) had bloodstream infection. While, none of the 18 S. maltophilia strains were found to be resistant against to trimethoprim sulfametaxasole (TMP-SXT) and levofloxacine, eight strains 66.6 % were found to be resistant against ceftazidim. Conclusion: The isolation of S.maltophilia starains resistant to TMP-SXT is vital. In order to prevent or minimize infections due to S. maltophilia such precuations should be utilized: Avoidance of inappropriate antibiotic use, prolonged implementation of foreign devices, reinforcement of hand hygiene practices and the application of appropriate infection control practices. Microbiology laboratories also may play important roles in controlling S. maltophilia infections by monitoring the prevalence, continuously, the provision of local antibiotic resistance paterns data and the performance of synergistic studies also may help to guide appropirate antimicrobial therapy choices.

Keywords: Stenotrophomonas maltophilia, trimethoprim-sulfamethoxazole, antimicrobial resistance, Stenotrophomonas spp.

Procedia PDF Downloads 246
242 Ultra-High Voltage Energization of Electrostatic Precipitators for Coal Fired Boilers

Authors: Mads Kirk Larsen

Abstract:

Strict air pollution control is today high on the agenda world-wide. By reducing the particular emission, not only the mg/Nm3 will be reduced – also parts of mercury and other hazardous matters attached to the particles will be reduced. Furthermore, it is possible to catch the fine particles (PM2.5). For particulate control, the precipitators are still the preferred choice and much efforts have been done to improve the efficiencies. Many ESP’s have seen electrical upgrading by changing the traditional 1 phase power system into either 3 phase or SMPS (High Frequency) units. However, there exist a 4th type of power supply – the pulse type. This is unfortunately widely unknown, but may be of great benefit to power plants. The FLSmidth type is called COROMAX® and it is a high voltage pulse generator for precipitators using a semiconductor switch operating at medium potential. The generated high voltage pulses have rated amplitude of 80 kV and duration of 75 μs and are superimposed on a variable base voltage of 60 kV rated voltage. Hereby, achieving a peak voltage of 140 kV. COROMAX® has the ability to increase the voltage beyond the natural spark limit inside the precipitator. Voltage levels may often be twice as high after installation of COROMAX®. Hereby also the migration velocity increases and thereby the efficiency. As the collection efficiency is proportional to the voltage peak and mean values, this also increases the collection efficiency of the fine particles where test has shown 80% removal of particles less than 0.07 micron. Another great advantage is the indifference to back-corona. Simultaneously with emission reduction, the power consumption will also be reduced. Another great advantage of the COROMAX® system is that the emission can be improved without the need to change the internal parts or enlarge the ESP. Recently, more than 150 units have been installed in China, where emissions have been reduced to ultra-low levels.

Keywords: eleectrostatic precipitator, high resistivity dust, micropulse energization, particulate removal

Procedia PDF Downloads 297
241 First Breeding Populations of The Glossy Ibis (Plegadis falcinellus) in a Peri-Urban Wetland Areas (Marsh of Boussedra; North-East of Algeria)

Authors: Boudraa Wahiba, Chettibi Farah, Lahlah Naouel, Bouslama Zihad, Houhamdi Moussa

Abstract:

The marsh of Boussedra (55 ha) is a peri-urban wetland, located in the city of El - Bouni, wilaya of Annaba (North-east of the Algeria). This city hosts every year, 53 species of waterfowl, belonging to 15 different families, of which the most represented family is the Anatidae with almost 12 species. The Glossy ibis (Plegadis falcinellus) is the only representative of the family of the threskiornithidae. After a total absence for almost a decade, this species has established in North Africa and started breeding since 2000. The Glossy ibis (plegadis falcinellus), breeds with low numbers in distant areas. At the wetland of Boussedra, the population of this species was observed with numbers approaching 160 individuals. During the breeding season of 2014 (between march and july), this species bred in mixed heronries (Cattle egret Bubulcus ibis , Little egret Egretta garzetta, The black-crowned night heron Nycticorax nycticorax , Squacco heron Ardeola ralloides and Little bittern Ixobrychus minutus), where a total of 120 nests were counted. This represents the largest colony observed in North Africa. The reproduction of the studied species took place on a Tamaricaceae (Tamarix gallica), where more than 2000 nest were constructed. During this breeding season, we have monitored the colony's installation and evolution and tried to characterize the reproduction, at the urban water plan of Boussedra (measurements of nests, measurements of eggs and monitoring the growing rate and weight gaining of the chicks, since their birth until their flight).

Keywords: glossy ibis, reproduction, peri-urban wetland, mixed heronry, Boussedra, Algeria

Procedia PDF Downloads 326
240 Small Scale Waste to Energy Systems: Optimization of Feedstock Composition for Improved Control of Ash Sintering and Quality of Generated Syngas

Authors: Mateusz Szul, Tomasz Iluk, Aleksander Sobolewski

Abstract:

Small-scale, distributed energy systems enabling cogeneration of heat and power based on gasification of sewage sludge, are considered as the most efficient and environmentally friendly ways of their treatment. However, economic aspects of such an investment are very demanding; therefore, for such a small scale sewage sludge gasification installation to be profitable, it needs to be efficient and simple at the same time. The article presents results of research on air gasification of sewage sludge in fixed bed GazEla reactor. Two of the most important aspects of the research considered the influence of the composition of sewage sludge blends with other feedstocks on properties of generated syngas and ash sintering problems occurring at the fixed bed. Different means of the fuel pretreatment and blending were proposed as a way of dealing with the above mentioned undesired characteristics. Influence of RDF (Refuse Derived Fuel) and biomasses in the fuel blends were evaluated. Ash properties were assessed based on proximate, ultimate, and ash composition analysis of the feedstock. The blends were specified based on complementary characteristics of such criteria as C content, moisture, volatile matter, Si, Al, Mg, and content of basic metals in the ash were analyzed, Obtained results were assessed with use of experimental gasification tests and laboratory ISO-procedure for analysis of ash characteristic melting temperatures. Optimal gasification process conditions were determined by energetic parameters of the generated syngas, its content of tars and lack of ash sinters within the reactor bed. Optimal results were obtained for co-gasification of herbaceous biomasses with sewage sludge where LHV (Lower Heating Value) of the obtained syngas reached a stable value of 4.0 MJ/Nm3 for air/steam gasification.

Keywords: ash fusibility, gasification, piston engine, sewage sludge

Procedia PDF Downloads 192
239 The Climate Change and Soil Degradation in the Czech Republic

Authors: Miroslav Dumbrovsky

Abstract:

The paper deals with impacts of climate change with the main emphasis on land degradation, agriculture and forestry management in the landscape. Land degradation, due to adverse effect of farmers activities, as a result of inappropriate conventional technologies, was a major issue in the Czech Republic during the 20th century and will remain for solving in the 21st century. The importance of land degradation is very high because of its impact on crop productivity and many other adverse effects. Land degradation through soil degradation is causing losses on crop productivity and quality of the environment, through decreasing quality of soil and water (especially water resources). Negative effects of conventional farming practices are increased water erosion, as well as crusting and compaction of the topsoil and subsoil. Soil erosion caused by water destructs the soil’s structure, reduces crop productivity due to deterioration in soil physical and chemical properties such as infiltration rate, water-holding capacity, loss of nutrients needed for crop production, and loss of soil carbon. Water erosion occurs on fields with row crops (maize, sunflower), especially during the rainfall period from April to October. Recently there is a serious problem of greatly expanded production of biofuels and bioenergy from field crops. The result is accelerated soil degradation. The damages (on and off- site) are greater than the benefits. An effective soil conservation requires an appropriate complex system of measures in the landscape. They are also important to continue to develop new sophisticated methods and technologies for decreasing land degradation. The system of soil conservation solving land degradation depend on the ability and the willingness of land users to apply them. When we talk about land degradation, it is not just a technical issue but also an economic and political issue. From a technical point of view, we have already made many positive steps, but for successful solving the problem of land degradation is necessary to develop suitable economic and political tools to increase the willingness and ability of land users to adopt conservation measures.

Keywords: land degradation, soil erosion, soil conservation, climate change

Procedia PDF Downloads 372
238 Dynamic Analysis and Clutch Adaptive Prefill in Dual Clutch Transmission

Authors: Bin Zhou, Tongli Lu, Jianwu Zhang, Hongtao Hao

Abstract:

Dual clutch transmissions (DCT) offer a high comfort performance in terms of the gearshift. Hydraulic multi-disk clutches are the key components of DCT, its engagement determines the shifting comfort. The prefill of the clutches requests an initial engagement which the clutches just contact against each other but not transmit substantial torque from the engine, this initial clutch engagement point is called the touch point. Open-loop control is typically implemented for the clutch prefill, a lot of uncertainties, such as oil temperature and clutch wear, significantly affects the prefill, probably resulting in an inappropriate touch point. Underfill causes the engine flaring in gearshift while overfill arises clutch tying up, both deteriorating the shifting comfort of DCT. Therefore, it is important to enable an adaptive capacity for the clutch prefills regarding the uncertainties. In this paper, a dynamic model of the hydraulic actuator system is presented, including the variable force solenoid and clutch piston, and validated by a test. Subsequently, the open-loop clutch prefill is simulated based on the proposed model. Two control parameters of the prefill, fast fill time and stable fill pressure is analyzed with regard to the impact on the prefill. The former has great effects on the pressure transients, the latter directly influences the touch point. Finally, an adaptive method is proposed for the clutch prefill during gear shifting, in which clutch fill control parameters are adjusted adaptively and continually. The adaptive strategy is changing the stable fill pressure according to the current clutch slip during a gearshift, improving the next prefill process. The stable fill pressure is increased by means of the clutch slip while underfill and decreased with a constant value for overfill. The entire strategy is designed in the Simulink/Stateflow, and implemented in the transmission control unit with optimization. Road vehicle test results have shown the strategy realized its adaptive capability and proven it improves the shifting comfort.

Keywords: clutch prefill, clutch slip, dual clutch transmission, touch point, variable force solenoid

Procedia PDF Downloads 307
237 Prescription of Lubricating Eye Drops in the Emergency Eye Department: A Quality Improvement Project

Authors: Noorulain Khalid, Unsaar Hayat, Muhammad Chaudhary, Christos Iosifidis, Felipe Dhawahir-Scala, Fiona Carley

Abstract:

Dry eye disease (DED) is a common condition seen in the emergency eye department (EED) at Manchester Royal Eye Hospital (MREH). However, there is variability in the prescription of lubricating eye drops among different healthcare providers. The aim of this study was to develop an up-to-date, standardized algorithm for the prescription of lubricating eye drops in the EED at MREH based on international and national guidelines. The study also aimed to assess the impact of implementing the guideline on the rate of inappropriate lubricant prescriptions. Primarily, the impact was to be assessed in the form of the appropriateness of prescriptions for patients’ DED. The impact was secondary to be assessed through analysis of the cost to the hospital. Data from 845 patients who attended the EED over a 3-month period were analyzed, and 157 patients met the inclusion and exclusion criteria. After conducting a review of the literature and collaborating with the corneal team, an algorithm for the prescription of lubricants in the EED was developed. Three plan-do-study-act (PDSA) cycles were conducted, with interventions such as emails, posters, in-person reminders, and education for incoming trainees. The appropriateness of prescriptions was evaluated against the guidelines. Data were collected from patient records and analyzed using statistical methods. The appropriateness of prescriptions was assessed by comparing them to the guidelines and by clinical correlation with a specialized registrar. The study found a substantial improvement in the number of appropriate prescriptions, with an increase from 55% to 93% over the three PDSA cycles. There was additionally a 51% reduction in expenditure on lubricant prescriptions, resulting in cost savings for the hospital (approximate saving of £50/week). Theoretical importance: Appropriate prescription of lubricating eye drops improves disease management for patients and reduces costs for the hospital. The development and implementation of a standardized guideline facilitate the achievement of these goals. Conclusion: This study highlights the inconsistent management of DED in the EED and the potential lack of training in this area for healthcare providers. The implementation of a standardized, easy-to-follow guideline for lubricating eye drops can help to improve disease management while also resulting in cost savings for the hospital.

Keywords: lubrication, dry eye disease, guideline, prescription

Procedia PDF Downloads 68
236 Evaluation of Automated Analyzers of Polycyclic Aromatic Hydrocarbons and Black Carbon in a Coke Oven Plant by Comparison with Analytical Methods

Authors: L. Angiuli, L. Trizio, R. Giua, A. Digilio, M. Tutino, P. Dambruoso, F. Mazzone, C. M. Placentino

Abstract:

In the winter of 2014 a series of measurements were performed to evaluate the behavior of real-time PAHs and black carbon analyzers in a coke oven plant located in Taranto, a city of Southern Italy. Data were collected both insides than outside the plant, at air quality monitoring sites. Contemporary measures of PM2.5 and PM1 were performed. Particle-bound PAHs were measured by two methods: (1) aerosol photoionization using an Ecochem PAS 2000 analyzer, (2) PM2.5 and PM1 quartz filter collection and analysis by gas chromatography/mass spectrometry (GC/MS). Black carbon was determined both in real-time by Magee Aethalometer AE22 analyzer than by semi-continuous Sunset Lab EC/OC instrument. Detected PM2.5 and PM1 levels were higher inside than outside the plant while PAHs real-time values were higher outside than inside. As regards PAHs, inside the plant Ecochem PAS 2000 revealed concentrations not significantly different from those determined on the filter during low polluted days, but at increasing concentrations the automated instrument underestimated PAHs levels. At the external site, Ecochem PAS 2000 real-time concentrations were steadily higher than those on the filter. In the same way, real-time black carbon values were constantly lower than EC concentrations obtained by Sunset EC/OC in the inner site, while outside the plant real-time values were comparable to Sunset EC values. Results showed that in a coke plant real-time analyzers of PAHs and black carbon in the factory configuration provide qualitative information, with no accuracy and leading to the underestimation of the concentration. A site specific calibration is needed for these instruments before their installation in high polluted sites.

Keywords: black carbon, coke oven plant, PAH, PAS, aethalometer

Procedia PDF Downloads 340
235 Data Centers’ Temperature Profile Simulation Optimized by Finite Elements and Discretization Methods

Authors: José Alberto García Fernández, Zhimin Du, Xinqiao Jin

Abstract:

Nowadays, data center industry faces strong challenges for increasing the speed and data processing capacities while at the same time is trying to keep their devices a suitable working temperature without penalizing that capacity. Consequently, the cooling systems of this kind of facilities use a large amount of energy to dissipate the heat generated inside the servers, and developing new cooling techniques or perfecting those already existing would be a great advance in this type of industry. The installation of a temperature sensor matrix distributed in the structure of each server would provide the necessary information for collecting the required data for obtaining a temperature profile instantly inside them. However, the number of temperature probes required to obtain the temperature profiles with sufficient accuracy is very high and expensive. Therefore, other less intrusive techniques are employed where each point that characterizes the server temperature profile is obtained by solving differential equations through simulation methods, simplifying data collection techniques but increasing the time to obtain results. In order to reduce these calculation times, complicated and slow computational fluid dynamics simulations are replaced by simpler and faster finite element method simulations which solve the Burgers‘ equations by backward, forward and central discretization techniques after simplifying the energy and enthalpy conservation differential equations. The discretization methods employed for solving the first and second order derivatives of the obtained Burgers‘ equation after these simplifications are the key for obtaining results with greater or lesser accuracy regardless of the characteristic truncation error.

Keywords: Burgers' equations, CFD simulation, data center, discretization methods, FEM simulation, temperature profile

Procedia PDF Downloads 163
234 A Prospective Audit to Look into Antimicrobial Prescribing in the Clinical Setting: In a Teaching Hospital in the UK

Authors: Richa Sinha, Mohammad Irfan Javed, Sanjay Singh

Abstract:

Introduction: Good antimicrobial prescribing reduces length of stay in hospital, risk of adverse events, antimicrobial resistance, and unnecessary hospital expenditure. The aim of this prospective audit was to identify any problems with antimicrobial prescribing including documentation of the relevant aspects as well as appropriateness of antibiotics use. The audit was conducted on the surgical wards in a teaching hospital in the UK. Methods: Standards included the indication, duration, choice, and prescription of antibiotic should be in line with current Regional Guidelines and should be clearly documented on the prescription chart. There should be an entry in each patients’ medical record of the diagnosis and indication for each acute antibiotic prescription issued. All prescriptions should clearly document the route, frequency and dose of antibiotic. Data collection was done for 2 weeks in the month of March 2014. A proforma including all the questions above was completed for all the patients. The results were analysed using Excel. Results: 35 patients in total were selected for the audit. 85.7% of patients had indication of antibiotic documented on the prescription chart and 68.5% of patients had indication documented in the notes. The antibiotic used was in line with hospital guidelines in 45.7% of patients, however, in a further 28.5% of patients the reason for the antibiotic prescription was microbiology approved. Therefore, in total 74.2% of patients had been prescribed appropriate antibiotics. The duration of antibiotic was documented in 68.6% of patients and the antibiotic was reviewed in 37.1% of patients. The dose, frequency and route was documented clearly in 100% of patients. Conclusion: Overall, prescribing can be improved on the surgical wards in this hospital. Only 37.1% of patients had clear documentation of a review of antibiotics. It may be that antibiotics have been reviewed but this should be clearly highlighted on the prescription chart or the notes. Failure to review antibiotics can lead to poor patient care and antimicrobial resistance and therefore it is important to address this. It is also important to address the appropriateness of antibiotics as inappropriate antibiotic prescription can lead to failure of treatment as well as antimicrobial resistance. The good points from the audit was that all patients had clear documentation of dose, route and frequency which is extremely important in the administration of antibiotics. Recommendations from this audit included to emphasize good antimicrobial prescribing at induction (twice yearly), an antimicrobial handbook for junior doctors, and re-audit in 6 months time.

Keywords: prescribing, antimicrobial, indication, duration

Procedia PDF Downloads 298
233 The Effect of Foot Progression Angle on Human Lower Extremity

Authors: Sungpil Ha, Ju Yong Kang, Sangbaek Park, Seung-Ju Lee, Soo-Won Chae

Abstract:

The growing number of obese patients in aging societies has led to an increase in the number of patients with knee medial osteoarthritis (OA). Artificial joint insertion is the most common treatment for knee medial OA. Surgery is effective for patients with serious arthritic symptoms, but it is costly and dangerous. It is also inappropriate way to prevent a disease as an early stage. Therefore Non-operative treatments such as toe-in gait are proposed recently. Toe-in gait is one of non-surgical interventions, which restrain the progression of arthritis and relieves pain by reducing knee adduction moment (KAM) to facilitate lateral distribution of load on to knee medial cartilage. Numerous studies have measured KAM in various foot progression angle (FPA), and KAM data could be obtained by motion analysis. However, variations in stress at knee cartilage could not be directly observed or evaluated by these experiments of measuring KAM. Therefore, this study applied motion analysis to major gait points (1st peak, mid –stance, 2nd peak) with regard to FPA, and to evaluate the effects of FPA on the human lower extremity, the finite element (FE) method was employed. Three types of gait analysis (toe-in, toe-out, baseline gait) were performed with markers placed at the lower extremity. Ground reaction forces (GRF) were obtained by the force plates. The forces associated with the major muscles were computed using GRF and marker trajectory data. MRI data provided by the Visible Human Project were used to develop a human lower extremity FE model. FE analyses for three types of gait simulations were performed based on the calculated muscle force and GRF. We observed the maximum stress point during toe-in gait was lower than the other types, by comparing the results of FE analyses at the 1st peak across gait types. This is the same as the trend exhibited by KAM, measured through motion analysis in other papers. This indicates that the progression of knee medial OA could be suppressed by adopting toe-in gait. This study integrated motion analysis with FE analysis. One advantage of this method is that re-modeling is not required even with changes in posture. Therefore another type of gait simulation or various motions of lower extremity can be easily analyzed using this method.

Keywords: finite element analysis, gait analysis, human model, motion capture

Procedia PDF Downloads 327
232 The Study of Heat and Mass Transfer for Ferrous Materials' Filtration Drying

Authors: Dmytro Symak

Abstract:

Drying is a complex technologic, thermal and energy process. Energy cost of drying processes in many cases is the most costly stage of production, and can be over 50% of total costs. As we know, in Ukraine over 85% of Portland cement is produced moist, and the finished product energy costs make up to almost 60%. During the wet cement production, energy costs make up over 5500 kJ / kg of clinker, while during the dry only 3100 kJ / kg, that is, switching to a dry Portland cement will allow result into double cutting energy costs. Therefore, to study raw materials drying process in the manufacture of Portland cement is very actual task. The fine ferrous materials drying (small pyrites, red mud, clay Kyoko) is recommended to do by filtration method, that is one of the most intense. The essence of filtration method drying lies in heat agent filtering through a stationary layer of wet material, which is located on the perforated partition, in the "layer-dispersed material - perforated partition." For the optimum drying purposes, it is necessary to establish the dependence of pressure loss in the layer of dispersed material, and the values of heat and mass transfer, depending on the speed of the gas flow filtering. In our research, the experimentally determined pressure loss in the layer of dispersed material was generalized based on dimensionless complexes in the form and coefficients of heat exchange. We also determined the relation between the coefficients of mass and heat transfer. As a result of theoretic and experimental investigations, it was possible to develop a methodology for calculating the optimal parameters for the thermal agent and the main parameters for the filtration drying installation. The comparison of calculated by known operating expenses methods for the process of small pyrites drying in a rotating drum and filtration method shows to save up to 618 kWh per 1,000 kg of dry material and 700 kWh during filtration drying clay.

Keywords: drying, cement, heat and mass transfer, filtration method

Procedia PDF Downloads 258
231 A Comparative Understanding of Critical Problems Faced by Pakistani and Indian Transportation Industry

Authors: Fawad Hussain, Saleh Abdullah Saleh, Mohammad Basir B Saud, Mohd Azwardi Md. Isa

Abstract:

It is very important for a developing nation to develop their infrastursture on the prime priority because their infrastursture particularly their roads and transporation functions as a blood in the system. Almost 1.1 billion populations share the travel and transportation industry in India. On the other hand, the Pakistan transportation industry is also extensive and elevating about 170 million users of transportation. Indian and Pakistani specifically within bus industry have good interconnectivity within and between the urban and rural areas as well as connectivity between the two countries, which is dramatically helping the economic alleviation of both countries. Due to high economic instability, unemployment and poverty rate are among the reasons why both the governments are very committed and seriously taken further action to help boost their economy. They believe that any form of transportation development would play a vital role in the development of land, infrastructure which could indirectly support many other industries’ development, such as tourism, freighting and shipping businesses, just to mention a few. However, it seems that their previous transportation planning in the due course has failed to meet the fast growing demand. As with the spin of time, both the countries are looking forward for a reasonable, safe and economical long term solutions, which is from time to time keep appreciating and reacting according to other key economic drivers. Content analysis method and case study approach is used in this paper and secondary data from the bureau of statistic is used for case analysis. The paper centered on the mobility concerns of the lower and middle income people in India and Pakistan. The paper is aimed to highlight the weaknesses, opportunities and limitations resulting from low priority industry for government, which is making the either country's public suffer. The paper has concluded that the main issue is identified as the slow, inappropriate and unfavorable decisions which are not in favor of long term country’s economic development and public welfare as well as interest. The paper also recommends to future market sense public and private transportation, which has failed to meet the public expectations.

Keywords: bus transportation industries, transportation demand, government parallel initiatives, road and traffic congestions

Procedia PDF Downloads 272
230 Structural Design for Effective Load Balancing of the Iron Frame in Manhole Lid

Authors: Byung Il You, Ryun Oh, Gyo Woo Lee

Abstract:

Manhole refers to facilities that are accessible to the people cleaning and inspection of sewer, and its covering is called manhole lid. Manhole lid is typically made of a cast iron material. Due to the heavy weight of the cast iron manhole lids their installation and maintenance are not easy, and an electrical shock and corrosion aging of them can cause critical problems. The manhole body and the lid manufacturing using the fiber-reinforced composite material can reduce the weight considerably compared to the cast iron manhole. But only the fiber reinforcing is hard to maintain the heavy load, and the method of the iron frame with double injection molding of the composite material has been proposed widely. In this study reflecting the situation of this market, the structural design of the iron frame for the composite manhole lid was carried out. Structural analysis with the computer simulation for the effectively distributed load on the iron frame was conducted. In addition, we want to assess manufacturing costs through the comparing of weights and number of welding spots of the frames. Despite the cross-sectional area is up to 38% compared with the basic solid form the maximum von Mises stress is increased at least about 7 times locally near the rim and the maximum strain in the central part of the lid is about 5.5 times. The number of welding points related to the manufacturing cost was increased gradually with the more complicated shape. Also, the higher the height of the arch in the center of the lid the better result might be obtained. But considering the economic aspect of the composite fabrication we determined the same thickness as the frame for the height of the arch at the center of the lid. Additionally in consideration of the number of the welding points we selected the hexagonal as the optimal shape. Acknowledgment: These are results of a study on the 'Leaders Industry-university Cooperation' Project, supported by the Ministry of Education (MOE).

Keywords: manhole lid, iron frame, structural design, computer simulation

Procedia PDF Downloads 271
229 Work-Related Risk Factors and Preventive Measures among Nurses and Dentists at Faculty of Oral and Dental Medicine

Authors: Marwa Mamdouh Shaban, Nagat Saied Habib, Shireen Ezz El-Din Taha, Eman Mahmoud Seif El-Naser

Abstract:

Background: Dental nurses and dentists were constantly exposed to a number of specific work related health risk factors which develop and intensify with years. Awareness regarding these work-related health risk factors and implementation of preventive health care measures could provide a safe work environment for all dental nurses and dentists. Aim of the study: to assess the work-related health risk factors among dental nurses and dentists and preventive health care measures applied among dental nurses and dentists. Research design: A descriptive design was utilized. Sample: Convenience sample of 50 dental nurses and 150 dentists were included in the current study. Setting: This study was conducted at the dental clinics at faculty of oral and dental medicine, Al-Kasr Al Ainy Hospital. Tools of data collection: Three tools were developed, tested for clarity, and feasibility: a-Socio-demographic data sheet, b-Work-related health risk factors questionnaire, and c-structured observational checklist. Results: The most common work risk factors prevailing among dental nurses were emotional exhaustion (82%), low back pain (76%) and latex allergy (62%) and the most common work risk factors prevailing among dentists were percutaneous exposure incident (100%), emotional exhaustion (100%) and low back pain (93.3%). Also, statistically significant negative correlation (r=-0.274, at p = 0.045) between the incidence of chemical health risk factors and application of chemical preventive measures among dental nurses. A statistically significant negative correlation (r=-0.177, at p = 0.030) between the incidences of mechanical health risk factors among dentists and application of mechanical preventive measures. Conclusion: The studied dental nurses and dentists exposed to many work related health risk factors as latex allergy, percutaneous exposure incidents, low back pain and emotional exhaustion related to inappropriate application of preventive health care measures. Recommendation: Raise awareness of dental nurses and dentists about work-related health risk factors, design and implement health education program for preventive health care measures.

Keywords: work-related risk factors, preventive measures, nurses, dentists

Procedia PDF Downloads 395
228 Minimizing Ship’S Breakdown Maintenance Due to Rope Entangled In Propeller With “Si Kuman” On Mooring Boat PSC I in Surabaya

Authors: Jogi Prayogo, Dwi Qaqa Prasetyatama, Rahmad Dwi Afandi, Kunto Arief Prasetyo, Viorel Herniza Leksono

Abstract:

PT. Pertamina Trans Kontinental managed a fleet of 364 ships in 2018 - 2020. In that period, there were 8 incidents of ship damage, causing breakdown maintenance on 6 ships belonging to PT Pertamina Trans Kontinental throughout Indonesia's operational areas due to ropes entangled in propellers. The company's losses that were caused by the fouled propellers amounted to 306.35 Million Rupiah. Of the 8 incidents, Mooring Boat PSC I was taken as a pilot project for further analysis considering the location of the ship which is in Surabaya and Mooring Boat PSC I has experienced 2 incidents of rope entanglement that caused the company's losses due to the largest Breakdown Maintenance amounted to 200.99 Million Rupiah. After analyzing the rope entanglement in the ship's propeller based on the data of Mooring Boat PSC I related to the location of propellers that are often fouled in the conventional propulsion system, it was found that there is a suitable location for the implementation of SI KUMAN tool that serves to cut ropes to prevent the occurrence of rope entangled in ship propellers. The determination of SI KUMAN tool is based on the strength of the ship's material to be installed and a suitable design to prevent the occurrence of ropes being entangled in propellers. After the installation of the "SI KUMAN" tool and monitoring carried out for 1 year period (August 2020 - August 2021), it was found that SI KUMAN tool can eliminate the risk of fouled propeller incidents which previously occurred twice in one year so that the company's loss amounted to 200.99 Million Rupiah can be eliminated and SI KUMAN tool can still operate optimally.

Keywords: breakdown maintenance, mooring boat, fleet, fouled propeller, rope entangled, cut

Procedia PDF Downloads 178
227 The Prevalence of Organized Retail Crime in Riyadh, Saudi Arabia

Authors: Saleh Dabil

Abstract:

This study investigates the level of existence of organized retail crime in supermarkets of Riyadh, Saudi Arabia. The store managers, security managers and general employees were asked about the types of retail crimes occur in the stores. Three independent variables were related to the report of organized retail theft. The independent variables are: (1) the supermarket profile (volume, location, standard and type of the store), (2) the social physical environment of the store (maintenance, cleanness and overall organizational cooperation), (3) the security techniques and loss prevention electronics techniques used. The theoretical framework of this study based on the social disorganization theory. This study concluded that the organized retail theft, in specific, organized theft is moderately apparent in Riyadh stores. The general result showed that the environment of the stores has an effect on the prevalence of organized retail theft with relation to the gender of thieves, age groups, working shift, type of stolen items as well as the number of thieves in one case. Among other reasons, some factors of the organized theft are: economic pressure of customers based on the location of the store. The dealing of theft also was investigated to have a clear picture of stores dealing with organized retail theft. The result showed that mostly, thieves sent without any action and sometimes given written warning. Very few cases dealt with by police. There are other factors in the study can be looked up in the text. This study suggests solving the problem of organized theft; first is ‘the well distributing of the duties and responsibilities between the employees especially for security purposes’. Second is ‘installation of strong security system’ and ‘making well-designed store layout’. Third is ‘giving training for general employees’ and ‘to give periodically security skills training of employees’. There are other suggestions in the study can be looked up in the text.

Keywords: organized crime, retail, theft, loss prevention, store environment

Procedia PDF Downloads 195
226 Increasing Power Transfer Capacity of Distribution Networks Using Direct Current Feeders

Authors: Akim Borbuev, Francisco de León

Abstract:

Economic and population growth in densely-populated urban areas introduce major challenges to distribution system operators, planers, and designers. To supply added loads, utilities are frequently forced to invest in new distribution feeders. However, this is becoming increasingly more challenging due to space limitations and rising installation costs in urban settings. This paper proposes the conversion of critical alternating current (ac) distribution feeders into direct current (dc) feeders to increase the power transfer capacity by a factor as high as four. Current trends suggest that the return of dc transmission, distribution, and utilization are inevitable. Since a total system-level transformation to dc operation is not possible in a short period of time due to the needed huge investments and utility unreadiness, this paper recommends that feeders that are expected to exceed their limits in near future are converted to dc. The increase in power transfer capacity is achieved through several key differences between ac and dc power transmission systems. First, it is shown that underground cables can be operated at higher dc voltage than the ac voltage for the same dielectric stress in the insulation. Second, cable sheath losses, due to induced voltages yielding circulation currents, that can be as high as phase conductor losses under ac operation, are not present under dc. Finally, skin and proximity effects in conductors and sheaths do not exist in dc cables. The paper demonstrates that in addition to the increased power transfer capacity utilities substituting ac feeders by dc feeders could benefit from significant lower costs and reduced losses. Installing dc feeders is less expensive than installing new ac feeders even when new trenches are not needed. Case studies using the IEEE 342-Node Low Voltage Networked Test System quantify the technical and economic benefits of dc feeders.

Keywords: DC power systems, distribution feeders, distribution networks, power transfer capacity

Procedia PDF Downloads 121
225 Antibiotic Prescribing in the Acute Care in Iraq

Authors: Ola A. Nassr, Ali M. Abd Alridha, Rua A. Naser, Rasha S. Abbas

Abstract:

Background: Excessive and inappropriate use of antimicrobial agents among hospitalized patients remains an important patient safety and public health issue worldwide. Not only does this behavior incur unnecessary cost but it is also associated with increased morbidity and mortality. The objective of this study is to obtain an insight into the prescribing patterns of antibiotics in surgical and medical wards, to help identify a scope for improvement in service delivery. Method: A simple point prevalence survey included a convenience sample of 200 patients admitted to medical and surgical wards in a government teaching hospital in Baghdad between October 2017 and April 2018. Data were collected by a trained pharmacy intern using a standardized form. Patient’s demographics and details of the prescribed antibiotics, including dose, frequency of dosing and route of administration, were reported. Patients were included if they had been admitted at least 24 hours before the survey. Patients under 18 years of age, having a diagnosis of cancer or shock, or being admitted to the intensive care unit, were excluded. Data were checked and entered by the authors into Excel and were subjected to frequency analysis, which was carried out on anonymized data to protect patient confidentiality. Results: Overall, 88.5% of patients (n=177) received 293 antibiotics during their hospital admission, with a small variation between wards (80%-97%). The average number of antibiotics prescribed per patient was 1.65, ranging from 1.3 for medical patients to 1.95 for surgical patients. Parenteral third-generation cephalosporins were the most commonly prescribed at a rate of 54.3% (n=159) followed by nitroimidazole 29.4% (n=86), quinolones 7.5% (n=22) and macrolides 4.4% (n=13), while carbapenems and aminoglycosides were the least prescribed together accounting for only 4.4% (n=13). The intravenous route was the most common route of administration, used for 96.6% of patients (n=171). Indications were reported in only 63.8% of cases. Culture to identify pathogenic organisms was employed in only 0.5% of cases. Conclusion: Broad-spectrum antibiotics are prescribed at an alarming rate. This practice may provoke antibiotic resistance and adversely affect the patient outcome. Implementation of an antibiotic stewardship program is warranted to enhance the efficacy, safety and cost-effectiveness of antimicrobial agents.

Keywords: Acute care, Antibiotic misuse, Iraq, Prescribing

Procedia PDF Downloads 121
224 Climate Change Impact on Slope Stability: A Study of Slope Drainage Design and Operation

Authors: Elena Mugarza, Stephanie Glendinning, Ross Stirling, Colin Davies

Abstract:

The effects of climate change and increased rainfall events on UK-based infrastructure are observable, with an increasing number being reported on in the national press. The fatal derailment at Stonehaven in 2020 prompted a wider review of Network Rail-owned earthworks assets. The event was indicated by the Rail Accident Investigation Branch (RAIB) to be caused by mis-installed drainage on the adjacent cutting. The slope failure on Snake Pass (public highway A57) was reportedly caused by significant water ingress following numerous storm events and resulted in the road’s closure for several months. This problem is only projected to continue with greater intensity and more prolonged rainfall events forecasted in the future. Subsequently, this project is designed to evaluate effective drainage trench design within infrastructure embankments, considering the capillary barrier phenomenon that may govern their deterioration and resultant failure. Theoretically, the differential between grain sizes of the embankment clays and gravels, customarily used in drainage trenches, would have a limiting effect on infiltration. As such, it is anticipated that the inclusion of an additional material with an intermediate grain size should improve the hydraulic conductivity across the drainage boundary. Multiple drainage designs will be studied using instrumentation within the drain and surrounding clays. Data from the real-world installation at the BIONICS embankment will be collected and compared with laboratory and Finite Element (FE) simulations. This research aims to reduce the risk of infrastructure slope failures by improving the resilience of earthwork drainage and lessening the consequential impact on transportation networks.

Keywords: earthworks, slope drainage, transportation slopes, deterioration, capillary barriers, field study

Procedia PDF Downloads 49
223 Prediction Study of a Corroded Pressure Vessel Using Evaluation Measurements and Finite Element Analysis

Authors: Ganbat Danaa, Chuluundorj Puntsag

Abstract:

The steel structures of the Oyu-Tolgoi mining Concentrator plant are corroded during operation, which raises doubts about the continued use of some important structures of the plant, which is one of the problems facing the plant's regular operation. As a part of the main operation of the plant, the bottom part of the pressure vessel, which plays an important role in the reliable operation of the concentrate filter-drying unit, was heavily corroded, so it was necessary to study by engineering calculations, modeling, and simulation using modern advanced engineering programs and methods. The purpose of this research is to investigate whether the corroded part of the pressure vessel can be used normally in the future using advanced engineering software and to predetermine the remaining life of the time of the pressure vessel based on engineering calculations. When the thickness of the bottom part of the pressure vessel was thinned by 0.5mm due to corrosion detected by non-destructive testing, finite element analysis using ANSYS WorkBench software was used to determine the mechanical stress, strain and safety factor in the wall and bottom of the pressure vessel operating under 2.2 MPa working pressure, made conclusions on whether it can be used in the future. According to the recommendations, by using sand-blast cleaning and anti-corrosion paint, the normal, continuous and reliable operation of the Concentrator plant can be ensured, such as ordering new pressure vessels and reducing the installation period. By completing this research work, it will be used as a benchmark for assessing the corrosion condition of steel parts of pressure vessels and other metallic and non-metallic structures operating under severe conditions of corrosion, static and dynamic loads, and other deformed steels to make analysis of the structures and make it possible to evaluate and control the integrity and reliable operation of the structures.

Keywords: corrosion, non-destructive testing, finite element analysis, safety factor, structural reliability

Procedia PDF Downloads 61
222 Associations between Metabolic Syndrome and Bone Mineral Density and Trabecular Bone Score in Postmenopausal Women with Non-Vertebral Fractures

Authors: Vladyslav Povoroznyuk, Larysa Martynyuk, Iryna Syzonenko, Liliya Martynyuk

Abstract:

Medical, social, and economic relevance of osteoporosis is caused by reducing quality of life, increasing disability and mortality of the patients as a result of fractures due to the low-energy trauma. This study is aimed to examine the associations of metabolic syndrome components, bone mineral density (BMD) and trabecular bone score (TBS) in menopausal women with non-vertebral fractures. 1161 menopausal women aged 50-79 year-old were examined and divided into three groups: A included 419 women with increased body weight (BMI - 25.0-29.9 kg/m2), B – 442 females with obesity (BMI >29.9 kg/m2)i and C – 300 women with metabolic syndrome (diagnosis according to IDF criteria, 2005). BMD of lumbar spine (L1-L4), femoral neck, total body and forearm was investigated with usage of dual-energy X-ray absorptiometry. The bone quality indexes were measured according to Med-Imaps installation. All analyses were performed using Statistical Package 6.0. BMD of lumbar spine (L1-L4), femoral neck, total body, and ultradistal radius was significant higher in women with obesity and metabolic syndrome compared to the pre-obese ones (p<0.001). TBS was significantly higher in women with increased body weight compared to obese and metabolic syndrome patients. Analysis showed significant positive correlation between waist circumference, triglycerides level and BMD of lumbar spine and femur. Significant negative association between serum HDL level and BMD of investigated sites was established. The TBS (L1-L4) indexes positively correlated with HDL (high-density lipoprotein) level. Despite the fact that BMD indexes were better in women with metabolic syndrome, the frequency of non-vertebral fractures was significantly higher in this group of patients.

Keywords: bone mineral density, trabecular bone score, metabolic syndrome, fracture

Procedia PDF Downloads 203