Search results for: effective dose
10376 Identifying Knowledge Gaps in Incorporating Toxicity of Particulate Matter Constituents for Developing Regulatory Limits on Particulate Matter
Authors: Ananya Das, Arun Kumar, Gazala Habib, Vivekanandan Perumal
Abstract:
Regulatory bodies has proposed limits on Particulate Matter (PM) concentration in air; however, it does not explicitly indicate the incorporation of effects of toxicities of constituents of PM in developing regulatory limits. This study aimed to provide a structured approach to incorporate toxic effects of components in developing regulatory limits on PM. A four-step human health risk assessment framework consists of - (1) hazard identification (parameters: PM and its constituents and their associated toxic effects on health), (2) exposure assessment (parameters: concentrations of PM and constituents, information on size and shape of PM; fate and transport of PM and constituents in respiratory system), (3) dose-response assessment (parameters: reference dose or target toxicity dose of PM and its constituents), and (4) risk estimation (metric: hazard quotient and/or lifetime incremental risk of cancer as applicable). Then parameters required at every step were obtained from literature. Using this information, an attempt has been made to determine limits on PM using component-specific information. An example calculation was conducted for exposures of PM2.5 and its metal constituents from Indian ambient environment to determine limit on PM values. Identified data gaps were: (1) concentrations of PM and its constituents and their relationship with sampling regions, (2) relationship of toxicity of PM with its components.Keywords: air, component-specific toxicity, human health risks, particulate matter
Procedia PDF Downloads 31110375 Treatment of Type 2 Diabetes Mellitus: Physicians’ Adherence to the American Diabetes Association Guideline in Central Region, Saudi Arabia
Authors: Ibrahim Mohammed
Abstract:
Background: Diabetes mellitus is a chronic disease that can cause devastating secondary complications, reducing the quality and length of life as well as increasing medical costs for the patient and society. The guidelines recommend both clinical and preventive strategies for diabetes management and are regularly updated. The aim of the study is to assess the level of adherence of physicians to American Diabetes Association Guidelines. Method: Observational multicenter retrospective study will be conducted among different hospitals in the central region. Patient data will be collected from the records of the last three years (2017- 2020). Records will be selected randomly after a complete randomized design. The study focuses on the management of type 2 according to ADA not changed in the last three updating; those standards; all patients should be taking Metformin 1500 to 2000 mg/day as recommended dose and should be received a high dose of statin if the high risk to ASCVD or moderate statin if not at risk, patients with hypertension and diabetes should taking ACE or ARBS. Result: The study aimed to evaluate the commitment of physicians in the central region to the ADA. Out of the 153 selected patients, only 17 % were able to control their diabetes with an average A1c below 7. ADA stated that to reach the minimum benefit of using Metformin, the daily dose should be between 1500 and 2000 mg. Results showed that 110 patients were on Metformin, where 68% of them were on the recommended dose. ADA recommended the intake of high statin for diabetic patients with ASCVD risk, while diabetic patients without ASCVD risk should be on a moderate statin. Results showed that 61.5% of patients with ASCVD risk were at high statin while only 36% of patients without ASCVD risk were at moderate statin. Results showed that 89 patients have hypertension, and 80% of them are getting ACE/ARBs as recommended by the ADA. Recommendation: It is necessary to implement periodic training courses for some physicians to enhance and update their knowledge.Keywords: American Diabetic Association, diabetes mellitus, atherosclerotic cardiovascular disease, ACE inhibitors
Procedia PDF Downloads 8510374 The acute effects caffeine on testosterone and cortisol in young football players after One Session Anaerobic exercise
Authors: S. Rostami, S. H. Hosseini, A. A. Torabi, M. Bekhradi
Abstract:
Introduction: Interest in the use of caffeine as an ergogenic aid has increased since the International Olympic Committee lifted the partial ban on its use. Caffeine has beneficial effects on various aspects of athletic performance, but its effects on training have been neglected. The purpose of this study was to investigate the acute effect of caffeine on testosterone and cortisole in young futsal players. Methods: Twenty-four professional futsal players with 18.3± 1.9 years ingested caffeine doses of 0, 200 and 800 mg in random order 1 hr before an anaerobic-exercise session (RAST test). Samples were taken at the time of caffeine ingestion and 30 min after the session. Data were log-transformed to estimate percent effects with mixed modeling, and effects were standardized to assess magnitudes. fects on training have been neglected. Results: Testosterone concentration showed a small increase of 15% (90% confidence limits, ± 19%) during exercise. Caffeine raised this concentration in a dose-dependent manner by a further small 21% (± 24%) at the highest dose. The 800-mg dose also produced a moderate 52% (± 44%) increase in cortisol. The effect of caffeine on the testosterone: cortisol ratio was a small decline (14%; ± 21%). Discussion and Conclusion: Caffeine has some potential to benefit training outcomes via the anabolic effects of the increase in testosterone concentration, but this benefit might be counteracted by the opposing catabolic effects of the increase in cortisol and resultant decline in the testosterone: cortisol ratio.Keywords: anabolic, catabolic, performance, testosterone, cortisol ratio, RAST test
Procedia PDF Downloads 44010373 High-Dose-Rate Brachytherapy for Cervical Cancer: The Effect of Total Reference Air Kerma on the Results of Single-Channel and Tri-Channel Applicators
Authors: Hossain A., Miah S., Ray P. K.
Abstract:
Introduction: Single channel and tri-channel applicators are used in the traditional treatment of cervical cancer. Total reference air kerma (TRAK) and treatment outcomes in high-dose-rate brachytherapy for cervical cancer using single-channel and tri-channel applicators were the main objectives of this retrospective study. Material and Methods: Patients in the radiotherapy division who received brachytherapy, chemotherapy, and external radiotherapy (EBRT) using single and tri-channel applicators were the subjects of a retrospective cohort study from 2016 to 2020. All brachytherapy parameters, including TRAK, were calculated in accordance with the international protocol. The Kaplan Meier method was used to analyze survival rates using a log-rank test. Results and Discussions: Based on treatment times of 15.34 (10-20) days and 21.35 (6.5-28) days, the TRAK for the tri-channel applicator was 0.52 cGy.m² and for the single-channel applicator was 0.34 cGy.m². Based on TRAK, the rectum, bladder, and tumor had respective Pearson correlations of 0.082, 0.009, and 0.032. The 1-specificity and sensitivity were 0.70 and 0.30, respectively. At that time, AUC was 0.71. The log-rank test showed that tri-channel applicators had a survival rate of 95% and single-channel applicators had a survival rate of 85% (p=0.565). Conclusions: The relationship between TRAK and treatment duration and Pearson correlation for the tumor, rectum, and bladder suggests that TRAK should be taken into account for the proper operation of single channel and tri-channel applicators.Keywords: single-channel, tri-channel, high dose rate brachytherapy, cervical cancer
Procedia PDF Downloads 10110372 Case Report: Opioid Sparing Anaesthesia with Dexmedetomidine in General Surgery
Authors: Shang Yee Chong
Abstract:
Perioperative pain is a complex mechanism activated by various nociceptive, neuropathic, and inflammatory pathways. Opioids have long been a mainstay for analgesia in this period, even as we are continuously moving towards a multimodal model to improve pain control while minimising side effects. Dexmedetomidine, a potent alpha-2 agonist, is a useful sedative and hypnotic agent. Its use in the intensive care unit has been well described, and it is increasingly an adjunct intraoperatively for its opioid sparing effects and to decrease pain scores. We describe a case of a general surgical patient in whom minimal opioids was required with dexmedetomidine use. The patient was a 61-year-old Indian gentleman with a history of hyperlipidaemia and type 2 diabetes mellitus, presenting with rectal adenocarcinoma detected on colonoscopy. He was scheduled for a robotic ultra-low anterior resection. The patient was induced with intravenous fentanyl 75mcg, propofol 160mg and atracurium 40mg. He was intubated conventionally and mechanically ventilated. Anaesthesia was maintained with inhalational desflurane and anaesthetic depth was measured with the Masimo EEG Sedline brain function monitor. An initial intravenous dexmedetomidine dose (bolus) of 1ug/kg for 10 minutes was given prior to anaesthetic induction and thereafter, an infusion of 0.2-0.4ug/kg/hr to the end of surgery. In addition, a bolus dose of intravenous lignocaine 1.5mg/kg followed by an infusion at 1mg/kg/hr throughout the surgery was administered. A total of 10mmol of magnesium sulphate and intravenous paracetamol 1000mg were also given for analgesia. There were no significant episodes of bradycardia or hypotension. A total of intravenous phenylephrine 650mcg was given throughout to maintain the patient’s mean arterial pressure within 10-15mmHg of baseline. The surgical time lasted for 5 hours and 40minutes. Postoperatively the patient was reversed and extubated successfully. He was alert and comfortable and pain scores were minimal in the immediate post op period in the postoperative recovery unit. Time to first analgesia was 4 hours postoperatively – with paracetamol 1g administered. This was given at 6 hourly intervals strictly for 5 days post surgery, along with celecoxib 200mg BD as prescribed by the surgeon regardless of pain scores. Oral oxycodone was prescribed as a rescue analgesic for pain scores > 3/10, but the patient did not require any dose. Neither was there nausea or vomiting. The patient was discharged on postoperative day 5. This case has reinforced the use of dexmedetomidine as an adjunct in general surgery cases, highlighting its excellent opioid-sparing effects. In the entire patient’s hospital stay, the only dose of opioid he received was 75mcg of fentanyl at the time of anaesthetic induction. The patient suffered no opioid adverse effects such as nausea, vomiting or postoperative ileus, and pain scores varied from 0-2/10. However, intravenous lignocaine infusion was also used in this instance, which would have helped improve pain scores. Paracetamol, lignocaine, and dexmedetomidine is thus an effective, opioid-sparing combination of multi-modal analgesia for major abdominal surgery cases.Keywords: analgesia, dexmedetomidine, general surgery, opioid sparing
Procedia PDF Downloads 13510371 Evaluating Radiation Dose for Interventional Radiologists Performing Spine Procedures
Authors: Kholood A. Baron
Abstract:
While radiologist numbers specialized in spine interventional procedures are limited in Kuwait, the number of patients demanding these procedures is increasing rapidly. Due to this high demand, the workload of radiologists is increasing, which might represent a radiation exposure concern. During these procedures, the doctor’s hands are in very close proximity to the main radiation beam/ if not within it. The aim of this study is to measure the radiation dose for radiologists during several interventional procedures for the spine. Methods: Two doctors carrying different workloads were included. (DR1) was performing procedures in the morning and afternoon shifts, while (DR2) was performing procedures in the morning shift only. Comparing the radiation exposures that the hand of each doctor is receiving will assess radiation safety and help to set up workload regulations for radiologists carrying a heavy schedule of such procedures. Entrance Skin Dose (ESD) was measured via TLD (ThermoLuminescent Dosimetry) placed at the right wrist of the radiologists. DR1 was covering the morning shift in one hospital (Mubarak Al-Kabeer Hospital) and the afternoon shift in another hospital (Dar Alshifa Hospital). The TLD chip was placed in his gloves during the 2 shifts for a whole week. Since DR2 was covering the morning shift only in Al Razi Hospital, he wore the TLD during the morning shift for a week. It is worth mentioning that DR1 was performing 4-5 spine procedures/day in the morning and the same number in the afternoon and DR2 was performing 5-7 procedures/day. This procedure was repeated for 4 consecutive weeks in order to calculate the ESD value that a hand receives in a month. Results: In general, radiation doses that the hand received in a week ranged from 0.12 to 1.12 mSv. The ESD values for DR1 for the four consecutive weeks were 1.12, 0.32, 0.83, 0.22 mSv, thus for a month (4 weeks), this equals 2.49 mSv and calculated to be 27.39 per year (11 months-since each radiologist have 45 days of leave in each year). For DR2, the weekly ESD values are 0.43, 0.74, 0.12, 0.61 mSv, and thus, for a month, this equals 1.9 mSv, and for a year, this equals 20.9 mSv /year. These values are below the standard level and way below the maximum limit of 500 mSv per year (set by ICRP = International Council of Radiation Protection). However, it is worth mentioning that DR1 was a senior consultant and hence needed less fluoro-time during each procedure. This is evident from the low ESD values of the second week (0.32) and the fourth week (0.22), even though he was performing nearly 10-12 procedures in a day /5 days a week. These values were lower or in the same range as those for DR2 (who was a junior consultant). This highlighted the importance of increasing the radiologist's skills and awareness of fluoroscopy time effect. In conclusion, the radiation dose that radiologists received during spine interventional radiology in our setting was below standard dose limits.Keywords: radiation protection, interventional radiology dosimetry, ESD measurements, radiologist radiation exposure
Procedia PDF Downloads 5810370 Analysis of Cell Cycle Status in Radiation Non-Targeted Hepatoma Cells Using Flow Cytometry: Evidence of Dose Dependent Response
Authors: Sharmi Mukherjee, Anindita Chakraborty
Abstract:
Cellular irradiation incites complex responses including arrest of cell cycle progression. This article accentuates the effects of radiation on cell cycle status of radiation non-targeted cells. Human Hepatoma HepG2 cells were exposed to increasing doses of γ radiations (1, 2, 4, 6 Gy) and their cell culture media was transferred to non-targeted HepG2 cells cultured in other Petri plates. These radiation non-targeted cells cultured in the ICCM (Irradiated cell conditioned media) were the bystander cells on which cell cycle analysis was performed using flow cytometry. An apparent decrease in the distribution of bystander cells at G0/G1 phase was observed with increased radiation doses upto 4 Gy representing a linear relationship. This was accompanied by a gradual increase in cellular distribution at G2/M phase. Interestingly the number of cells in G2/M phase at 1 and 2 Gy irradiation was not significantly different from each other. However, the percentage of G2 phase cells at 4 and 6 Gy doses were significantly higher than 2 Gy dose indicating the IC50 dose to be between 2 and 4 Gy. Cell cycle arrest is an indirect indicator of genotoxic damage in cells. In this study, bystander stress signals through the cell culture media of irradiated cells disseminated the radiation induced DNA damages in the non-targeted cells which resulted in arrest of the cell cycle progression at G2/M phase checkpoint. This implies that actual radiation biological effects represent a penumbra with effects encompassing a larger area than the actual beam. This article highlights the existence of genotoxic damages as bystander effects of γ rays in human Hepatoma cells by cell cycle analysis and opens up avenues for appraisal of bystander stress communications between tumor cells. Contemplation of underlying signaling mechanisms can be manipulated to maximize damaging effects of radiation with minimum dose and thus has therapeutic applications.Keywords: bystander effect, cell cycle, genotoxic damage, hepatoma
Procedia PDF Downloads 18410369 Ytterbium Advantages for Brachytherapy
Authors: S. V. Akulinichev, S. A. Chaushansky, V. I. Derzhiev
Abstract:
High dose rate (HDR) brachytherapy is a method of contact radiotherapy, when a single sealed source with an activity of about 10 Ci is temporarily inserted in the tumor area. The isotopes Ir-192 and (much less) Co-60 are used as active material for such sources. The other type of brachytherapy, the low dose rate (LDR) brachytherapy, implies the insertion of many permanent sources (up to 200) of lower activity. The pulse dose rate (PDR) brachytherapy can be considered as a modification of HDR brachytherapy, when the single source is repeatedly introduced in the tumor region in a pulse regime during several hours. The PDR source activity is of the order of one Ci and the isotope Ir-192 is currently used for these sources. The PDR brachytherapy is well recommended for the treatment of several tumors since, according to oncologists, it combines the medical benefits of both HDR and LDR types of brachytherapy. One of the main problems for the PDR brachytherapy progress is the shielding of the treatment area since the longer stay of patients in a shielded canyon is not enough comfortable for them. The use of Yb-169 as an active source material is the way to resolve the shielding problem for PDR, as well as for HRD brachytherapy. The isotope Yb-169 has the average photon emission energy of 93 KeV and the half-life of 32 days. Compared to iridium and cobalt, this isotope has a significantly lower emission energy and therefore requires a much lighter shielding. Moreover, the absorption cross section of different materials has a strong Z-dependence in that photon energy range. For example, the dose distributions of iridium and ytterbium have a quite similar behavior in the water or in the body. But the heavier material as lead absorbs the ytterbium radiation much stronger than the iridium or cobalt radiation. For example, only 2 mm of lead layer is enough to reduce the ytterbium radiation by a couple of orders of magnitude but is not enough to protect from iridium radiation. We have created an original facility to produce the start stable isotope Yb-168 using the laser technology AVLIS. This facility allows to raise the Yb-168 concentration up to 50 % and consumes much less of electrical power than the alternative electromagnetic enrichment facilities. We also developed, in cooperation with the Institute of high pressure physics of RAS, a new technology for manufacturing high-density ceramic cores of ytterbium oxide. Ceramics density reaches the limit of the theoretical values: 9.1 g/cm3 for the cubic phase of ytterbium oxide and 10 g/cm3 for the monoclinic phase. Source cores from this ceramics have high mechanical characteristics and a glassy surface. The use of ceramics allows to increase the source activity with fixed external dimensions of sources.Keywords: brachytherapy, high, pulse dose rates, radionuclides for therapy, ytterbium sources
Procedia PDF Downloads 49110368 Study of Natural Radioactive and Radiation Hazard Index of Soil from Sembrong Catchment Area, Johor, Malaysia
Authors: M. I. A. Adziz, J. Sharib Sarip, M. T. Ishak, D. N. A. Tugi
Abstract:
Radiation exposure to humans and the environment is caused by natural radioactive material sources. Given that exposure to people and communities can occur through several pathways, it is necessary to pay attention to the increase in naturally radioactive material, particularly in the soil. Continuous research and monitoring on the distribution and determination of these natural radionuclides' activity as a guide and reference are beneficial, especially in an accidental exposure. Surface soil/sediment samples from several locations identified around the Sembrong catchment area were taken for the study. After 30 days of secular equilibrium with their daughters, the activity concentrations of the naturally occurring radioactive material (NORM) members, i.e. ²²⁶Ra, ²²⁸Ra, ²³⁸U, ²³²Th, and ⁴⁰K, were measured using high purity germanium (HPGe) gamma spectrometer. The results obtained showed that the radioactivity concentration of ²³⁸U ranged between 17.13 - 30.13 Bq/kg, ²³²Th ranged between 22.90 - 40.05 Bq/kg, ²²⁶Ra ranged between 19.19 - 32.10 Bq/kg, ²²⁸Ra ranged between 21.08 - 39.11 Bq/kg and ⁴⁰K ranged between 9.22 - 51.07 Bq/kg with average values of 20.98 Bq/kg, 27.39 Bq/kg, 23.55 Bq/kg, 26.93 Bq/kg and 23.55 Bq/kg respectively. The values obtained from this study were low or equivalent to previously reported in previous studies. It was also found that the mean/mean values obtained for the four parameters of the Radiation Hazard Index, namely radium equivalent activity (Raeq), external dose rate (D), annual effective dose and external hazard index (Hₑₓ), were 65.40 Bq/kg, 29.33 nGy/h, 19.18 ¹⁰⁻⁶Sv and 0.19 respectively. These obtained values are low compared to the world average values and the values of globally applied standards. Comparison with previous studies (dry season) also found that the values for all four parameters were low and equivalent. This indicates the level of radiation hazard in the area around the study is safe for the public.Keywords: catchment area, gamma spectrometry, naturally occurring radioactive material (NORM), soil
Procedia PDF Downloads 10110367 Alternative Mathematical form for Determining the Effectiveness of High-LET Radiations at Lower Doses Region
Authors: Abubaker A. Yousif, Muhamad S. Yasir
Abstract:
The Effectiveness of lower doses of high-LET radiations is not accurately determined by using energy-based physical parameters such as absorbed dose and radio-sensitivity parameters. Therefore, an attempt has been carried out in this research to propose alternative parameter that capable to quantify the effectiveness of these high LET radiations at lower doses regions. The linear energy transfer and mean free path are employed to achieve this objective. A new mathematical form of the effectiveness of high-LET radiations at lower doses region has been formulated. Based on this parameter, the optimized effectiveness of high-LET radiations occurs when the energy of charged particles is deposited at spacing of 2 nm for primary ionization.Keywords: effectiveness, low dose, radiation mean free path, linear energy transfer
Procedia PDF Downloads 46110366 The Immunosuppressive Effects of Silymarin with Rapamaycin on the Proliferation and Apoptosis of T Cell
Authors: Nahid Eskandari, Marjan Ghagozolo, Ehsan Almasi
Abstract:
Introduction: Silymarin, as a polyphenolic flavonoid derived from milk thistle (Silybum marianum), is known to have antioxidant, immunomodulatory, antiproliferative, antifibrotic, and antiviral effects. The goal of this study was to determine immunosuppressive effect of Silymarin on proliferation and apoptosis of human T cells in comparison with Rapamycin and FK506. Methods: Peripheral Blood Mononuclear Cells (PBMCs) from healthy individuals were activated with Con A (5µg/ml) and then treated with Silymarin, Rapamycin and FK506 in various concentrations (0.001, 0.01, 0.1, 1, 10,100 and 200M) for 5 days. PBMCs were examined for proliferation using CFSE assay and the concentration that inhibited 50% of the cell proliferation (IC50) was determined for each treatment. For apoptosis assay using flow cytometry, PBMCs were activated with Con A and treated with IC50 dose of Silymarin, Rapamycin and FK506 for 5 days, then cell apoptosis was analysed by FITC-annexin V/PI staining and flow cytometry. The effects of Silymarin, Rapamycin and FK506 on the activation of PARP (poly ADP ribose polymerase) pathway in PBMCs stimulated with Con A and treated with IC50 dose of drugs for 5 days evaluated using the PathScan cleaved PARP sandwich ELISA kit. Results: This study showed that Silymarin had the ability to inhibit T cell proliferation in vitro. Moreover, our results indicated that 100 μM (P < 0.001) and 200 μM (P < 0.001) of Silymarin has more inhibitory effect on T cells proliferation than FK506 and Rapamycin. Our data showed that the effective doses (IC50) of Silymarin, FK506 and Rapamycin were 3×10-5 µM, 10-8 µM and 10-6 µM respectively. Data showed that the inhibitory effect of Silymarin, FK506 and Rapamycin on T cell proliferation was not due to cytotoxicity and none of these drugs at IC50 concentration had not affected the level of cleaved PARP. Conclusion: Silymarin could be a good candidate for immunosuppressive therapy for certain medical conditions with superior efficacy and lesser toxicity in comparison with other immunosuppressive drugs.Keywords: silymarin, immunosuppressive effect, rapamycin, immunology
Procedia PDF Downloads 27010365 Relationship between Effective Classroom Management with Students’ Academic Achievement of EFL of STKIP YPUP
Authors: Eny Syatriana
Abstract:
The purpose of this study is to find out the effective instruction for classroom management, with the main identification of organizing and managing effective learning environments, to identify characteristics of effective lesson planning, identify resources and materials dealing with positive and effective classroom management. Knowing the effective instruction management is one of the characteristics of well managed teacher. The study was carried out in three randomly selected classes of STKIP YPUP in South Sulawesi. The design adopted for the study was a descriptive survey approach. Simple descriptive analysis was used. The major instrument used in this study were student questionnaire, teacher questionnaire, data were gathered with the research instrument and were analyzed, the research question were investigated and two hypothesis were duly tested using t-test statistics. Based on the findings of this research, it was concluded that effective classroom management skills or techniques have strong and positive influence on student achievement.Keywords: effective classroom management skills, students’ achievement, students academic, effective learning environments
Procedia PDF Downloads 33310364 Bio-Equivalence of Doxycycline in Two Preparations in Broiler Chickens
Authors: Abdelrazzag Elmajdoub
Abstract:
The present study was designed to investigate the bio-equivalence of doxycycline in Dolistin® and Colidox® at a dose rate of 10 mg doxycycline/kg of body weight in 48 clinically normal broiler chickens. After oral administration, plasma levels of doxycycline peaked after 2 hours post-dosing without significant differences between the two products and it could be detected therapeutically and exceeded the minimum inhibitory concentration (MIC) for most micro-organisms sensitive to doxycycline for 12 hours. The disposition kinetics of doxycycline in the two products following oral administration revealed that the maximum plasma concentrations (Cmax.) were 22.65 and 21.80 µg/ml and attained at (Tmax.) 2.10 and 2.20 hours, respectively. Doxycycline in both of the products was eliminated with half- lives (t0.5α) equal to 7.70 and 6.93 hours, respectively. The mean systemic bio availabilities of doxycycline in both of the products after oral administration in chickens were 80.60 and 79.70%, respectively. It was concluded that doxycycline in the form of Dolistin® and Colidox® needs a dose equivalent to 20 mg doxycycline/kg of body weight a day is better to keep the plasma concentration higher than the MIC.Keywords: tetracyclines, doxycycline, bioavailability, broilers, chickens
Procedia PDF Downloads 50610363 Unconventional Dating of Old Peepal Tree of Chandigarh (India) Using Optically Stimulated Luminescence
Authors: Rita Rani, Ramesh Kumar
Abstract:
The intend of the current study is to date an old grand Peepal tree that is still alive. The tree is situated in Kalibard village, Sector 9, Chandigarh (India). Due to its huge structure, it has got the status of ‘Heritage tree.’ Optically Stimulated Luminescence of sediments beneath the roots is used to determine the age of the tree. Optical dating is preferred over conventional dating methods due to more precession. The methodology includes OSL of quartz grain using SAR protocol for accumulated dose measurement. The age determination of an alive tree using sedimentary quartz is in close agreement with the approximated age provided by the related agency. This is the first attempt at using optically stimulated luminescence in the age determination of alive trees in this region. The study concludes that the Luminescence dating of alive trees is the nondestructive and more precise method.Keywords: luminescence, dose rate, optical dating, sediments
Procedia PDF Downloads 17610362 Evaluation of the Anti Ulcer Activity of Ethyl Acetate Fraction of Methanol Leaf Extract of Clerodendrum Capitatum
Authors: M. N. Ofokansi, Onyemelukwe Chisom, Amauche Chukwuemeka, Ezema Onyinye
Abstract:
The leaves of Clerodendrumcapitatum(Lamiaceae) is mostly used in the treatment of gastric ulcer in Nigerian folk medicine. The aim of this study was to evaluate the antiulcer activity of its crude methanol leaf extract and its ethyl acetate fraction in white albino rats. The effect of crude methanol leaf extract and its ethyl acetate fraction(250mg/kg, 500mg/kg) was evaluated using an absolute ethanol induced ulcer model. Crude methanol leaf extract and the ethyl acetate fraction was treated with distilled water and 6% Tween 80, respectively. crude methanol leaf extract was further investigated using a pylorus ligation induced ulcer model. Omeprazole was used as the standard treatment. Four groups of five albino rats of either sex were used. Parameters such as mean ulcer index and percentage ulcer protection were assessed in the ethanol-induced ulcer model, while the gastric volume, pH, and total acidity were assessed in the pyloric ligation induced ulcer model. Crude methanol leaf extract of Clerodendrumcapitatum(500mg/kg) showed a very highly significant reduction in mean ulcer index(p<0.001) in the absolute ethanol-induced model. ethyl acetate fraction of crude methanol leaf extract of Clerodendrumcapitatum(250mg/kg,500mg/kg) showed a very highly significant dose-dependent reduction in mean ulcer indices (p<0.001) in the absolute ethanol-induced model. The mean ulcer indices (1.6,2.2) with dose concentration (250mg/kg, 500mg/kg) of ethyl acetate fraction increased with ulcer protection (82.85%,76.42%) respectively when compared to the control group in the absolute ethanol-induced ulcer model. Crude methanol leaf extract of Clerodendrumcapitatum(250mg/kg, 500mg/kg) treated animals showed a highly significant dose-dependent reduction in mean ulcer index(p<0.01) with an increase in ulcer protection (56.77%,63.22%) respectively in pyloric ligated induced, ulcer model. Gastric parameters such as volume of gastric juice, pH, and total acidity were of no significance in the different doses of the crude methanol leaf extract when compared to the control group. The phytochemical investigation showed that the crude methanol leaf extracts Possess Saponins and Flavonoids while its ethyl acetate fraction possess only Flavonoids. The results of the study indicate that the crude methanol leaf extract and its ethyl acetate fraction is effective and has gastro protective and ulcer healing capacity. Ethyl acetate fraction is more potent than crude methanol leaf extract against ethanol-induced This result provides scientific evidence as a validation for its folkloric use in the treatment of gastric ulcer.Keywords: gastroprotective, herbal medicine, anti-ulcer, pharmacology
Procedia PDF Downloads 16210361 The Anti-Obesity Effects of the Aqueous and Ethanolic Leaf Extracts of Blumea balsamifera on Diet-Induced Obese Sprague-Dawley Rats
Authors: Mae Genevieve G. Cheung, Michael G. Cuevas, Lovely Fe L. Cuison, Elijin P. Dai, Katrina Marie S. Duron, Azalea Damaris E. Encarnacion, May T. Magtoto, Gina C. Castro
Abstract:
The present study aims to evaluate the effectiveness of aqueous and ethanolic leaf extracts of Blumea balsamifera in reducing obesity on diet-induced obese Sprague-Dawley rats. Aqueous and ethanolic leaf extracts were obtained by maceration and percolation, respectively, of air-dried, grinded leaves. The test animals were given a high fat diet (HFD) for 21 days, except for one negative control group fed with a standard diet (SD). The Blumea balsamifera extracts were given at doses of 300 mg/Kg and 600 mg/Kg for BBAE and BBEE groups, and the positive control group, Orlistat, was given at 21.6 mg/Kg dose. After 24 days of treatment, the statistical difference of parameters such as Lee’s index and lipid profile of each group before and after the treatment period were determined separately using Tukey’s test of two-way Analysis of Variance (ANOVA). The statistical results showed that the600mg/kg dose of BBAE and BBEE had greatly lowered the Lee’s index among the other doses while the 300 mg/Kg dose BBEE, 600 mg/Kg BBAE, and 300 mg/kg BBAE lowered the total cholesterol level, LDL level, and VLDL and total triglyceride level respectively. The extracts, however, lowered the HDL level which was also exhibited by the standard drug, Orlistat.Keywords: adipocytes, adipogenesis, Blumea balsamifera, Lee’s index, obesity, Sambong
Procedia PDF Downloads 37610360 In vitro Antiviral Activity of Ocimum sanctum against Animal Viruses
Authors: Anjana Goel, Ashok Kumar Bhatia
Abstract:
Ocimum sanctum, a well known medicinal plant is used for various alignments in Ayurvedic medicines. It was found to be effective in treating the humans suffering from different viral infections like chicken pox, small pox, measles and influenza. In addition, curative effect of the plant in malignant patients was also reported. In the present study, leaves of this plant were screened against animal viruses i.e. Bovine Herpes Virus-type-1 (BHV-1), Foot and Mouth disease virus (FMDV) and Newcastle Disease Virus (NDV). BHV-1 and FMDV were screened in MDBK and BHK cell lines respectively using cytopathic inhibition test. While NDV was propagated in chick embryo fibroblast culture and tested by haemagglutination inhibition test. Maximum non toxic dose of aqueous extract of Ocimum sanctum leaves was calculated by MTT assay in all the cell cultures and nontoxic doses were used for antiviral activity against viruses. 98.4% and 85.3% protection were recorded against NDV and BHV-1 respectively. However, Ocimum sanctum extract failed to show any inhibitory effect on the cytopathic effect caused by FMD virus. It can be concluded that Ocimum sanctum is a very effective remedy for curing viral infections in animals also.Keywords: bovine herpes virus-type-1, foot and mouth disease virus, newcastle disease virus, Ocimum sanctum
Procedia PDF Downloads 27110359 Designing a Dispersion Flattened Single Mode PCF for E-Band to U-Band with Less Effective Area
Authors: Shabbir Chowdhury
Abstract:
A signal is broadened when it is gone through a channel, this phenomenon is known as dispersion. And dispersion is different for different wavelength. So bandwidth become limited. Research have tried to design an optical fiber with flattened dispersion to use more bandwidth and also for wavelength division multiplexing. In this paper, a single mode photonic crystal fiber with a flattened dispersion and less effective area has been proposed where silica is used as fiber materials. The effective dispersion varies from -1.996 to 0.1783 [ps/(nm-km)] for enter E-band to U-band. This fiber will take only 3.048 [micrometer^2] (for 1.75 micrometer wavelength). Silica is being used as the fiber material.Keywords: photonic crystal fiber, dispersion, bandwidth, chromatic dispersion, effective dispersion, dispersion compensation, effective area, effective refractive index
Procedia PDF Downloads 41510358 A Questionnaire Survey Reviewing Radiographers' Knowledge of Computed Tomography Exposure Parameters
Authors: Mohammad Rawashdeh, Mark McEntee, Maha Zaitoun, Mostafa Abdelrahman, Patrick Brennan, Haytham Alewaidat, Sarah Lewis, Charbel Saade
Abstract:
Despite the tremendous advancements that have been generated by Computed Tomography (CT) in the field of diagnosis, concerns have been raised about the potential cancer induction risk from CT because of the exponentially increased use of it in medicine. This study aims at investigating the application and knowledge of practicing radiographers in Jordan about CT radiation. In order to collect the primary data of this study, a questionnaire was designed and distributed by social media using a snow-balling sampling method. The respondents (n=54) have answered 36 questions including the questions about their demographic information, knowledge about Diagnostic Reference Levels (DRLs), CT exposure and adaptation of pediatric patients exposure. The educational level of the respondents was either at a diploma degree (35.2%) or bachelor (64.8%). The results of this study have indicated a good level of general knowledge between radiographers about the relationship between image quality, exposure parameters, and patient dose. The level of knowledge related to DRL was poor where less than 7.4 percent of the sample members were able to give specific values for a number of common anatomical fields, including abdomen, brain, and chest. Overall, Jordanian radiographers need to gain more knowledge about the expected levels of the dose when applying good practice. Additional education on DRL or DRL inclusion in educational programs is highlighted.Keywords: computed tomography, CT scan, DRLs, exposure parameters, image quality, radiation dose
Procedia PDF Downloads 14310357 Patten of Heparin Dosing as Venous Thromboembolism Prophylaxis in Adult Underweight Patients Admitted to Critical Care Units at a Tertiary Hospital
Authors: Nouf Al Harthi
Abstract:
Venous thromboembolism (VTE) is one of the most common causes of hospital-related deaths in critically ill patients. Guidelines recommended VTE prophylaxis with standardized, fixed doses for most patients. The underweight population has limited data to guide the appropriate drug and dosing regimen. The aim of this study was to describe the pattern of VTE prophylaxis dose regimens for underweighted critically ill adult patients and the prevalence of associated VTE and bleeding. This study is a retrospective cohort study, conducted in King Abdulaziz Medical City, Saudi Arabia. It included all critical patients admitted to the intensive care units and were above 14 years old with weight less than 50 kg or BMI of 18.5 kg/m2 or less and were on heparin as VTE prophylaxis for more than 72 hours from January 2016 until January 2020. After screening 270 patients, only 40 patients were included in this study according to our inclusion and exclusion criteria. Only 6 patients (15%) received VTE prophylaxis as an adjusted dose of heparin 2500 U Q12, while the rest of the patients were taking standard dosing of heparin, 5000 U Q12 was given to 21 (52.50%) patients and 5000 U Q8 was given to 13 (32.50%) patients. None of the adjusted doses developed any complications such as VTE or bleeding. There was no significant difference compared with the standard dose group. This study focused on describing the pattern of heparin doses as VTE prophylaxis in underweight patients. We also compared the standard dosing and adjusted dosage of VTE prophylaxis on underweight patients and any complications. There was no significant difference in the complication’s outcome or benefits between the two groups.Keywords: venous thromboembolism prophylaxis, heparin, underweight patients, adult, critical care units
Procedia PDF Downloads 10110356 Radiation Dosimetry Using Sintered Pellets of Yellow Beryl (Heliodor) Crystals
Authors: Lucas Sátiro Do Carmo, Betzabel Noemi Silva Carrera, Shigueo Watanabe, J. F. D. Chubaci
Abstract:
Beryl is a silicate with chemical formula Be₃Al₂(SiO₃)₆ commonly found in Brazil. It has a few colored variations used as jewelry, like Aquamarine (blueish), Emerald (green) and Heliodor (yellow). The color of each variation depends on the dopant that is naturally present in the crystal lattice. In this work, Heliodor pellets of 5 mm diameter and 1 mm thickness have been produced and investigated using thermoluminescence (TL) to evaluate its potential for use as gamma ray’s dosimeter. The results show that the pellets exhibited a prominent TL peak at 205 °C that grows linearly with dose when irradiated from 1 Gy to 1000 Gy. A comparison has been made between powdered and sintered dosimeters. The results show that sintered pellets have higher sensitivity than powder dosimeter. The TL response of this mineral is satisfactory for radiation dosimetry applications in the studied dose range.Keywords: dosimetry, beryl, gamma rays, sintered pellets, new material
Procedia PDF Downloads 9610355 Duration of the Disease in Systemic Sclerosis and Efficiency of Rituximab Therapy
Authors: Liudmila Garzanova, Lidia Ananyeva, Olga Koneva, Olga Ovsyannikova, Oxana Desinova, Mayya Starovoytova, Rushana Shayahmetova, Anna Khelkovskaya-Sergeeva
Abstract:
Objectives: The duration of the disease could be one of the leading factors in the effectiveness of therapy in systemic sclerosis (SSc). The aim of the study was to assess how the duration of the disease affects the changes of lung function in patients(pts) with interstitial lung disease (ILD) associated with SSc during long-term RTX therapy. Methods: We prospectively included 113pts with SSc in this study. 85% of pts were female. Mean age was 48.1±13years. The diffuse cutaneous subset of the disease had 62pts, limited–40, overlap–11. The mean disease duration was 6.1±5.4years. Pts were divided into 2 groups depending on the disease duration - group 1 (less than 5 years-63pts) and group 2 (more than 5 years-50 pts). All pts received prednisolone at mean dose of 11.5±4.6 mg/day and 53 of them - immunosuppressants at inclusion. The parameters were evaluated over the periods: at baseline (point 0), 13±2.3mo (point 1), 42±14mo (point 2) and 79±6.5mo (point 3) after initiation of RTX therapy. Cumulative mean dose of RTX in group 1 at point 1 was 1.7±0.6 g, at point 2 = 3.3±1.5g, at point 3 = 3.9±2.3g; in group 2 at point 1 = 1.6±0.6g, at point 2 = 2.7±1.5 g, at point 3 = 3.7±2.6 g. The results are presented in the form of mean values, delta(Δ), median(me), upper and lower quartile. Results. There was a significant increase of forced vital capacity % predicted (FVC) in both groups, but at points 1 and 2 the improvement was more significant in group 1. In group 2, an improvement of FVC was noted with a longer follow-up. Diffusion capacity for carbon monoxide % predicted (DLCO) remained stable at point 1, and then significantly improved by the 3rd year of RTX therapy in both groups. In group 1 at point 1: ΔFVC was 4.7 (me=4; [-1.8;12.3])%, ΔDLCO = -1.2 (me=-0.3; [-5.3;3.6])%, at point 2: ΔFVC = 9.4 (me=7.1; [1;16])%, ΔDLCO =3.7 (me=4.6; [-4.8;10])%, at point 3: ΔFVC = 13 (me=13.4; [2.3;25.8])%, ΔDLCO = 2.3 (me=1.6; [-5.6;11.5])%. In group 2 at point 1: ΔFVC = 3.4 (me=2.3; [-0.8;7.9])%, ΔDLCO = 1.5 (me=1.5; [-1.9;4.9])%; at point 2: ΔFVC = 7.6 (me=8.2; [0;12.6])%, ΔDLCO = 3.5 (me=0.7; [-1.6;10.7]) %; at point 3: ΔFVC = 13.2 (me=10.4; [2.8;15.4])%, ΔDLCO = 3.6 (me=1.7; [-2.4;9.2])%. Conclusion: Patients with an early SSc have more quick response to RTX therapy already in 1 year of follow-up. Patients with a disease duration more than 5 years also have response to therapy, but with longer treatment. RTX is effective option for the treatment of ILD-SSc, regardless of the duration of the disease.Keywords: interstitial lung disease, systemic sclerosis, rituximab, disease duration
Procedia PDF Downloads 2310354 Efficacy of Gamma Radiation on the Productivity of Bactrocera oleae Gmelin (Diptera: Tephritidae)
Authors: Mehrdad Ahmadi, Mohamad Babaie, Shiva Osouli, Bahareh Salehi, Nadia Kalantaraian
Abstract:
The olive fruit fly, Bactrocera oleae Gmelin (Diptera: Tephritidae), is one of the most serious pests in olive orchards in growing province in Iran. The female lay eggs in green olive fruit and larvae hatch inside the fruit, where they feed upon the fruit matters. One of the main ecologically friendly and species-specific systems of pest control is the sterile insect technique (SIT) which is based on the release of large numbers of sterilized insects. The objective of our work was to develop a SIT against B. oleae by using of gamma radiation for the laboratory and field trial in Iran. Oviposition of female mated by irradiated males is one of the main parameters to determine achievement of SIT. To conclude the sterile dose, pupae were placed under 0 to 160 Gy of gamma radiation. The main factor in SIT is the productivity of females which are mated by irradiated males. The emerged adults from irradiated pupae were mated with untreated adults of the same age by confining them inside the transparent cages. The fecundity of the irradiated males mated with non-irradiated females was decreased with the increasing radiation dose level. It was observed that the number of eggs and also the percentage of the egg hatching was significantly (P < 0.05) affected in either IM x NF crosses compared with NM x NF crosses in F1 generation at all doses. Also, the statistical analysis showed a significant difference (P < 0.05) in the mean number of eggs laid between irradiated and non-irradiated females crossed with irradiated males, which suggests that the males were susceptible to gamma radiation. The egg hatching percentage declined markedly with the increase of the radiation dose of the treated males in mating trials which demonstrated that egg hatch rate was dose dependent. Our results specified that gamma radiation affects the longevity of irradiated B. oleae larvae (established from irradiated pupae) and significantly increased their larval duration. Results show the gamma radiation, and SIT can be used successfully against olive fruit flies.Keywords: fertility, olive fruit fly, radiation, sterile insect technique
Procedia PDF Downloads 19610353 Hepatoprotective Effect of Oleuropein against Cisplatin-Induced Liver Damage in Rat
Authors: Salim Cerig, Fatime Geyikoglu, Murat Bakir, Suat Colak, Merve Sonmez, Kubra Koc
Abstract:
Cisplatin (CIS) is one of the most effective an anticancer drug and also toxic to cells by activating oxidative stress. Oleuropein (OLE) has key role against oxidative stress in mammalian cells, but the role of this antioxidant in the toxicity of CIS remains unknown. The aim of the present study was to investigate the efficacy of OLE on CIS-induced liver damages in male rats. With this aim, male Sprague Dawley rats were randomly assigned to one of eight groups: Control group; the group treated with 7 mg/kg/day CIS; the groups treated with 50, 100 and 200 mg/kg/day OLE (i.p.); and the groups treated with OLE for three days starting at 24 h following CIS injection. After 4 days of injections, serum was provided to assess the blood AST, ALT and LDH values. The liver tissues were removed for histological, biochemical (TAC, TOS and MDA) and genotoxic evaluations. In the CIS treated group, the whole liver tissue showed significant histological changes. Also, CIS significantly increased both the incidence of oxidative stress and the induction of 8-hydroxy-deoxyguanosine (8-OH-dG). Moreover, the rats taking CIS have abnormal results on liver function tests. However, these parameters reached to the normal range after administration of OLE for 3 days. Finally, OLE demonstrated an acceptable high potential and was effective in attenuating CIS-induced liver injury. In this trial, the 200 mg/kg dose of OLE firstly appeared to induce the most optimal protective response.Keywords: antioxidant response, cisplatin, histology, liver, oleuropein, 8-OhdG
Procedia PDF Downloads 34010352 Response of Newzealand Rabbits to Drinking Water Treated with PolyDADMAC
Authors: Amna Beshir Medani Ahmed, Samia Mohammed Ali El Badwi, Ahmed El Amin Mohammed
Abstract:
This work has been managed to yield toxicity information on water treatment agents in the Sudan namely polyDADMAC, using New Zealand rabbits at multiple daily oral doses for a period of 10 weeks. Thirty-three heads of New Zealand rabbits were divided into 11 groups, each of three. Group 1 animals were the undosed controls. Test groups of either species were given polyDADMAC at similar dose rates of 0.5, 2.5, 4.5, 10, 15, 20, 25, 50, 100 and 150 mg/kg body weight respectively for groups 2,3,4,5,6,7,8,9,10 and 11. Clinical signs were closely observed with postmortem and histopathological examinations. Chemical investigations included enzymatic concentrations of ALP, GOT, CK, GPT and LDH together with hematological changes in Hb, PCV, RBCs and WBCs. Mortalities occurred to variable degrees irrespective of the dose level. On polyDADMAC challenge, the test species showed clinical signs of dullness, loss of weight, anorexia, diarrhea, difficulty in respiration, hind limb paralysis and recumbency. Notably oral dosing with polyDADMAC caused lung emphysema, hepatic and renal dysfunctions, irregularity in enzymatic activities and serum metabolites, sloughing of intestinal epithelium, decreased electrolytes in serum, and splenic haemosiderosis. On evaluation of the above results, polyDADMAC was considered toxic to New Zealand rabbits at all dose rates tried. Practical implications of the results were highlighted and suggestions for future work were put forward.Keywords: polydiallyldiethylaluminiumchloride (polyDADMAC), nubian goats, toxicity of drinking water, treatment of drinking water using chemicals
Procedia PDF Downloads 37210351 Treatment of Acid Mine Lake by Ultrasonically Modified Fly Ash at Different Frequencies
Authors: Burcu Ileri, Deniz Sanliyuksel Yucel, Onder Ayyildiz
Abstract:
The oxidation of pyrite in water results in the formation of acid mine drainage, which typically forms extremely acid mine lake (AML) in the depression areas of abandoned Etili open-pit coal mine site, Northwest Turkey. Nine acid mine lakes of various sizes have been located in the Etili coal mine site. Hayirtepe AML is one of the oldest lake having a mean pH value of 2.9 and conductivity of 4550 μS/cm, and containing elevated concentrations of Al, B, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, and Zn. The water quality of the lake has been deteriorated due to its high chemical composition, in particular, increasing heavy metal pollution. In this study, fly ash (FA), a coal combustion by-product from fluidized bed thermal power plant in the northwestern part of Turkey, was used as an adsorbent for the treatment of Hayirtepe AML. The FA is a relatively abundant and cost effective material, but its use in adsorption processes usually require excessive adsorbent doses. To increase adsorption efficiency and lower the adsorbent dose, we modified the FA by means of ultrasonic treatment (20 kHz and 40 kHz). The images of scanning electron microscopy (SEM) have demonstrated that ultrasonic treatment not only decreased the size of ash particles but also created pits and cracks on their surfaces which in turn led to a significant increase in the BET surface area. Both FA and modified fly ash were later tested for the removal of heavy metals from the AML. The effect of various operating parameters such as ultrasonic power, pH, ash dose, and adsorption contact time were examined to obtain the optimum conditions for the treatment process. The results have demonstrated that removal of heavy metals by ultrasound-modified fly ash requires much shorter treatment times and lower adsorbent doses than those attained by the unmodified fly ash. This research was financially supported by the Scientific and Technological Research Council of Turkey (TUBITAK), (Project no: 116Y510).Keywords: acid mine lake, heavy metal, modified fly ash, ultrasonic treatment
Procedia PDF Downloads 19810350 Kinetic and Thermodynamic Study of Nitrates Removal by Sorption on Biochar
Authors: Amira Touil, Achouak Arfaoui, Ibtissem Mannaii
Abstract:
The aim of this work is to monitor the process adsorption of nitrates by the biochar via studying the influence of various parameters on the adsorption of this pollutant by biochar in a synthetic aqueous solution. The results which obtained indicate that the 4g/L biochar dose is the most efficient in terms of nitrates removal in aqueous solution. The biochar exhibited a good affinity for nitrates after 1hour of contact. The yield of removal of nitrate by the biochar decreases with the increase of pH of the solution and increases with increasing temperature (60°C>40°C>20°C). The best removal yield is about 80% of the initial concentration introduced (25mg/L) obtained at pH=2, T=60°C, and dose of biochar=4g/L. The second order model fit the nitrate adsorption kinetics of biochar with a high coefficient of determination (R2≥0.997); and a new equation correlating the rate constant of the reaction with temperature and pH was been built. Freundlich isotherms performed well to fit the nitrate adsorption data by biochar (R2>0.96) compared to Langmuir isotherms. The thermodynamic parameters (ΔH°, ΔG°, ΔS°) have been calculated for predicting the nature of adsorption.Keywords: pollution, biochar, nitrate, adsorption
Procedia PDF Downloads 9510349 Cardiac Pacemaker in a Patient Undergoing Breast Radiotherapy-Multidisciplinary Approach
Authors: B. Petrović, M. Petrović, L. Rutonjski, I. Djan, V. Ivanović
Abstract:
Objective: Cardiac pacemakers are very sensitive to radiotherapy treatment from two sources: electromagnetic influence from the medical linear accelerator producing ionizing radiation- influencing electronics within the pacemaker, and the absorption of dose to the device. On the other hand, patients with cardiac pacemakers at the place of a tumor are rather rare, and single clinic hardly has experience with the management of such patients. The widely accepted international guidelines for management of radiation oncology patients recommend that these patients should be closely monitored and examined before, during and after radiotherapy treatment by cardiologist, and their device and condition followed up. The number of patients having both cancer and pacemaker, is growing every year, as both cancer incidence, as well as cardiac diseases incidence, are inevitably growing figures. Materials and methods: Female patient, age 69, was diagnozed with valvular cardiomyopathy and got implanted a pacemaker in 2005 and prosthetic mitral valve in 1993 (cancer was diagnosed in 2012). She was stable cardiologically and came to radiation therapy department with the diagnosis of right breast cancer, with the tumor in upper lateral quadrant of the right breast. Since she had all lymph nodes positive (28 in total), she had to have irradiated the supraclavicular region, as well as the breast with the tumor bed. She previously received chemotherapy, approved by the cardiologist. The patient was estimated to be with the high risk as device was within the field of irradiation, and the patient had high dependence on her pacemaker. The radiation therapy plan was conducted as 3D conformal therapy. The delineated target was breast with supraclavicular region, where the pacemaker was actually placed, with the addition of a pacemaker as organ at risk, to estimate the dose to the device and its components as recommended, and the breast. The targets received both 50 Gy in 25 fractions (where 20% of a pacemaker received 50 Gy, and 60% of a device received 40 Gy). The electrode to the heart received between 1 Gy and 50 Gy. Verification of dose planned and delivered was performed. Results: Evaluation of the patient status according to the guidelines and especially evaluation of all associated risks to the patient during treatment was done. Patient was irradiated by prescribed dose and followed up for the whole year, with no symptoms of failure of the pacemaker device during, or after treatment in follow up period. The functionality of a device was estimated to be unchanged, according to the parameters (electrode impedance and battery energy). Conclusion: Patient was closely monitored according to published guidelines during irradiation and afterwards. Pacemaker irradiated with the full dose did not show any signs of failure despite recommendations data, but in correlation with other published data.Keywords: cardiac pacemaker, breast cancer, radiotherapy treatment planning, complications of treatment
Procedia PDF Downloads 43810348 A Dose Distribution Approach Using Monte Carlo Simulation in Dosimetric Accuracy Calculation for Treating the Lung Tumor
Authors: Md Abdullah Al Mashud, M. Tariquzzaman, M. Jahangir Alam, Tapan Kumar Godder, M. Mahbubur Rahman
Abstract:
This paper presents a Monte Carlo (MC) method-based dose distributions on lung tumor for 6 MV photon beam to improve the dosimetric accuracy for cancer treatment. The polystyrene which is tissue equivalent material to the lung tumor density is used in this research. In the empirical calculations, TRS-398 formalism of IAEA has been used, and the setup was made according to the ICRU recommendations. The research outcomes were compared with the state-of-the-art experimental results. From the experimental results, it is observed that the proposed based approach provides more accurate results and improves the accuracy than the existing approaches. The average %variation between measured and TPS simulated values was obtained 1.337±0.531, which shows a substantial improvement comparing with the state-of-the-art technology.Keywords: lung tumour, Monte Carlo, polystyrene, Elekta synergy, Monaco planning system
Procedia PDF Downloads 44510347 PET/CT Patient Dosage Assay
Authors: Gulten Yilmaz, A. Beril Tugrul, Mustafa Demir, Dogan Yasar, Bayram Demir, Bulent Buyuk
Abstract:
A Positron Emission Tomography (PET) is a radioisotope imaging technique that illustrates the organs and the metabolisms of the human body. This technique is based on the simultaneous detection of 511 keV annihilation photons, annihilated as a result of electrons annihilating positrons that radiate from positron-emitting radioisotopes that enter biological active molecules in the body. This study was conducted on ten patients in an effort to conduct patient-related experimental studies. Dosage monitoring for the bladder, which was the organ that received the highest dose during PET applications, was conducted for 24 hours. Assessment based on measuring urination activities after injecting patients was also a part of this study. The MIRD method was used to conduct dosage calculations for results obtained from experimental studies. Results obtained experimentally and theoretically were assessed comparatively.Keywords: PET/CT, TLD, MIRD, dose measurement, patient doses
Procedia PDF Downloads 521