119 Pelvic Floor Electrophysiology Patterns Associated with Obstructed Defecation

Authors: Emmanuel Kamal Aziz Saba, Gihan Abd El-Lateif Younis El-Tantawi, Mohammed Hamdy Zahran, Ibrahim Khalil Ibrahim, Mohammed Abd El-Salam Shehata, Hussein Al-Moghazy Sultan, Medhat

Abstract:

Pelvic floor electrophysiological tests are essential for assessment of patients with obstructed defecation. The present study was conducted to determine the different patterns of pelvic floor electrophysiology that are associated with obstructed defecation. The present cross sectional study included 25 patients with obstructed defecation. A control group of 20 apparently healthy subjects were included. All patients were subjected to history taking, clinical examination, proctosigmoidoscopy, lateral proctography (evacuation proctography), dynamic pelvic magnetic resonance imaging, anal manometry and electrophysiological studies. Electrophysiological studies were including pudendal nerve motor conduction study, pudendo-anal reflex, needle electromyography of external anal sphincter and puborectalis muscles, pudendal somatosensory evoked potential and tibial somatosensory evoked potential. The control group was subjected to electrophysiological studies which included pudendal nerve motor conduction study, pudendo-anal reflex, pudendal somatosensory evoked potential and tibial somatosensory evoked potential. The most common pelvic floor electrodiagnostic pattern characteristics of obstructed defecation was pudendal neuropathy, denervation and anismus of external anal sphincter and puborectalis with complete interference pattern of external anal sphincter and puborectalis at squeezing and cough and no localized defect in external anal sphincter. In conclusion, there were characteristic pelvic floor electrodiagnostic patterns associated with obstructed defecation.

Keywords: obstructed defecation, pudendal nerve terminal motor latency, pudendoanal reflex, sphincter electromyography

Procedia PDF Downloads 408
118 Comparison of Trunk and Hip Muscle Activities and Anterior Pelvic Tilt Angle during Three Different Bridging Exercises in Subjects with Chronic Low Back Pain

Authors: Da-Eun Kim, Heon-Seock Cynn, Sil-Ah Choi, A-Reum Shin

Abstract:

Bridging exercise in supine position with the hips and knees flexed have been commonly performed as one of the therapeutic exercises and is a comfortable and pain-free position to most individuals with chronic low back pain (CLBP). Many previous studies have investigated the beneficial way of performing bridging exercises to improve activation of abdominal and gluteal muscle and reduce muscle activity of hamstrings (HAM) and erector spinae (ES) and compensatory lumbopelvic motion. The purpose of this study was to compare the effects of three different bridging exercises on the HAM, ES, gluteus maximus (Gmax), gluteus medius (Gmed), and transverse abdominis/internal abdominis oblique (TrA/IO) activities and anterior pelvic tilt angle in subjects with CLBP. Seventeen subjects with CLBP participated in this study. They performed bridging under three different conditions (with 30° hip abduction, isometric hip abduction, and isometric hip adduction). Surface electromyography was used to measure muscle activity, and the ImageJ software was used to calculate anterior pelvic tilt angle. One-way repeated-measures analysis of variance was used to assess the statistical significance of the measured variables. HAM activity was significantly lower in bridging with 30° hip abduction and isometric hip abduction than in bridging with isometric hip adduction. Gmax and Gmed activities were significantly greater in bridging with isometric hip abduction than in bridging with 30° hip abduction and isometric hip adduction. TrA/IO muscle activity was significantly greater and anterior pelvic tilt angle was significantly lower in bridging with isometric hip adduction than in bridging with 30° hip abduction and isometric hip abduction. Bridging with isometric hip abduction using Thera-Band can effectively reduce HAM activity, and increase Gmax and Gmed activities in subjects with CLBP. Bridging with isometric hip adduction using a pressure biofeedback unit can be a beneficial exercise to improve TrA/IO activity and minimize anterior pelvic tilt in subjects with CLBP.

Keywords: bridging exercise, electromyography, low back pain, lower limb exercise

Procedia PDF Downloads 189
117 Antagonist Coactivation in Athletes Following Anterior Cruciate Ligament Reconstruction

Authors: Milad Pirali, Sohrab Keyhani, Mohhamad Ali Sanjari, Ali Ashraf Jamshidi

Abstract:

Purpose: The effect of hamstring antagonist activity on the knee extensors torque of the Anterior Cruciate Ligament reconstruction (ACLR) is not clear and persistent muscle weakness is common after ACLR. Hamstring activation when acting as antagonist is considered very important for knee strengths. Therefore the purpose of this study was to examine hamstring antagonist coactivation during maximal effort of the isokinetic knee extension in ACLR athletes with hamstring autograft. Materials and Methods: We enrolled 20 professional athletes who underwent primary ACLR (hamstring tendon autograft)with 6-24 months postoperative and 20 healthy subjects as control group. Each subjects performed maximal effort isokinetic knee extension and flexion in 60/˚ s and 180/˚ s velocities for the involved and uninvolved limb. Synchronously, surface electromyography (EMG) was recorded of vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF) and biceps femoris (BF). The antagonist integrated EMG (IEMG) values were normalized to the IEMG of the same muscle during maximal isokinetic eccentric effort at the same velocities and ROM. Results: A one-way analysis of variance designs shows significantly greater IEMG coactivation of hamstring and decreased activation of Vm in ACLR when compared to uninvolved and control group leg in 60/˚ s and 180/˚ s velocities. Likewise peak torque to body weight was decreased in ACLR compared to uninvolved and control group during knee extension in both velocities (p < 0.05). Conclusions: Decreased extensors moment caused by decreased quadriceps inhibition and increased hamstring coactivation. In addition, these result indicated to decrease of motor unit recruitment in the VM (as a kinesiologicmonitore of the knee). It is appearing that strengthening of the quadriceps to be an important for rehabilitation program after ACLR for preparation in athletes endeavors. Therefore, we suggest that having more emphasis and focus on quadriceps strength and less emphasis on hamstring following ACLR.

Keywords: ACLR-coactivation, dynamometry, electromyography, isokinetic

Procedia PDF Downloads 224
116 High-Resolution Facial Electromyography in Freely Behaving Humans

Authors: Lilah Inzelberg, David Rand, Stanislav Steinberg, Moshe David Pur, Yael Hanein

Abstract:

Human facial expressions carry important psychological and neurological information. Facial expressions involve the co-activation of diverse muscles. They depend strongly on personal affective interpretation and on social context and vary between spontaneous and voluntary activations. Smiling, as a special case, is among the most complex facial emotional expressions, involving no fewer than 7 different unilateral muscles. Despite their ubiquitous nature, smiles remain an elusive and debated topic. Smiles are associated with happiness and greeting on one hand and anger or disgust-masking on the other. Accordingly, while high-resolution recording of muscle activation patterns, in a non-interfering setting, offers exciting opportunities, it remains an unmet challenge, as contemporary surface facial electromyography (EMG) methodologies are cumbersome, restricted to the laboratory settings, and are limited in time and resolution. Here we present a wearable and non-invasive method for objective mapping of facial muscle activation and demonstrate its application in a natural setting. The technology is based on a recently developed dry and soft electrode array, specially designed for surface facial EMG technique. Eighteen healthy volunteers (31.58 ± 3.41 years, 13 females), participated in the study. Surface EMG arrays were adhered to participant left and right cheeks. Participants were instructed to imitate three facial expressions: closing the eyes, wrinkling the nose and smiling voluntary and to watch a funny video while their EMG signal is recorded. We focused on muscles associated with 'enjoyment', 'social' and 'masked' smiles; three categories with distinct social meanings. We developed a customized independent component analysis algorithm to construct the desired facial musculature mapping. First, identification of the Orbicularis oculi and the Levator labii superioris muscles was demonstrated from voluntary expressions. Second, recordings of voluntary and spontaneous smiles were used to locate the Zygomaticus major muscle activated in Duchenne and non-Duchenne smiles. Finally, recording with a wireless device in an unmodified natural work setting revealed expressions of neutral, positive and negative emotions in face-to-face interaction. The algorithm outlined here identifies the activation sources in a subject-specific manner, insensitive to electrode placement and anatomical diversity. Our high-resolution and cross-talk free mapping performances, along with excellent user convenience, open new opportunities for affective processing and objective evaluation of facial expressivity, objective psychological and neurological assessment as well as gaming, virtual reality, bio-feedback and brain-machine interface applications.

Keywords: affective expressions, affective processing, facial EMG, high-resolution electromyography, independent component analysis, wireless electrodes

Procedia PDF Downloads 219
115 Comparison of Bioelectric and Biomechanical Electromyography Normalization Techniques in Disparate Populations

Authors: Drew Commandeur, Ryan Brodie, Sandra Hundza, Marc Klimstra

Abstract:

The amplitude of raw electromyography (EMG) is affected by recording conditions and often requires normalization to make meaningful comparisons. Bioelectric methods normalize with an EMG signal recorded during a standardized task or from the experimental protocol itself, while biomechanical methods often involve measurements with an additional sensor such as a force transducer. Common bioelectric normalization techniques for treadmill walking include maximum voluntary isometric contraction (MVIC), dynamic EMG peak (EMGPeak) or dynamic EMG mean (EMGMean). There are several concerns with using MVICs to normalize EMG, including poor reliability and potential discomfort. A limitation of bioelectric normalization techniques is that they could result in a misrepresentation of the absolute magnitude of force generated by the muscle and impact the interpretation of EMG between functionally disparate groups. Additionally, methods that normalize to EMG recorded during the task may eliminate some real inter-individual variability due to biological variation. This study compared biomechanical and bioelectric EMG normalization techniques during treadmill walking to assess the impact of the normalization method on the functional interpretation of EMG data. For the biomechanical method, we normalized EMG to a target torque (EMGTS) and the bioelectric methods used were normalization to the mean and peak of the signal during the walking task (EMGMean and EMGPeak). The effect of normalization on muscle activation pattern, EMG amplitude, and inter-individual variability were compared between disparate cohorts of OLD (76.6 yrs N=11) and YOUNG (26.6 yrs N=11) adults. Participants walked on a treadmill at a self-selected pace while EMG was recorded from the right lower limb. EMG data from the soleus (SOL), medial gastrocnemius (MG), tibialis anterior (TA), vastus lateralis (VL), and biceps femoris (BF) were phase averaged into 16 bins (phases) representing the gait cycle with bins 1-10 associated with right stance and bins 11-16 with right swing. Pearson’s correlations showed that activation patterns across the gait cycle were similar between all methods, ranging from r =0.86 to r=1.00 with p<0.05. This indicates that each method can characterize the muscle activation pattern during walking. Repeated measures ANOVA showed a main effect for age in MG for EMGPeak but no other main effects were observed. Interactions between age*phase of EMG amplitude between YOUNG and OLD with each method resulted in different statistical interpretation between methods. EMGTS normalization characterized the fewest differences (four phases across all 5 muscles) while EMGMean (11 phases) and EMGPeak (19 phases) showed considerably more differences between cohorts. The second notable finding was that coefficient of variation, the representation of inter-individual variability, was greatest for EMGTS and lowest for EMGMean while EMGPeak was slightly higher than EMGMean for all muscles. This finding supports our expectation that EMGTS normalization would retain inter-individual variability which may be desirable, however, it also suggests that even when large differences are expected, a larger sample size may be required to observe the differences. Our findings clearly indicate that interpretation of EMG is highly dependent on the normalization method used, and it is essential to consider the strengths and limitations of each method when drawing conclusions.

Keywords: electromyography, EMG normalization, functional EMG, older adults

Procedia PDF Downloads 63
114 Estimation of Forces Applied to Forearm Using EMG Signal Features to Control of Powered Human Arm Prostheses

Authors: Faruk Ortes, Derya Karabulut, Yunus Ziya Arslan

Abstract:

Myoelectric features gathering from musculature environment are considered on a preferential basis to perceive muscle activation and control human arm prostheses according to recent experimental researches. EMG (electromyography) signal based human arm prostheses have shown a promising performance in terms of providing basic functional requirements of motions for the amputated people in recent years. However, these assistive devices for neurorehabilitation still have important limitations in enabling amputated people to perform rather sophisticated or functional movements. Surface electromyogram (EMG) is used as the control signal to command such devices. This kind of control consists of activating a motion in prosthetic arm using muscle activation for the same particular motion. Extraction of clear and certain neural information from EMG signals plays a major role especially in fine control of hand prosthesis movements. Many signal processing methods have been utilized for feature extraction from EMG signals. The specific objective of this study was to compare widely used time domain features of EMG signal including integrated EMG(IEMG), root mean square (RMS) and waveform length(WL) for prediction of externally applied forces to human hands. Obtained features were classified using artificial neural networks (ANN) to predict the forces. EMG signals supplied to process were recorded during only type of muscle contraction which is isometric and isotonic one. Experiments were performed by three healthy subjects who are right-handed and in a range of 25-35 year-old aging. EMG signals were collected from muscles of the proximal part of the upper body consisting of: biceps brachii, triceps brachii, pectorialis major and trapezius. The force prediction results obtained from the ANN were statistically analyzed and merits and pitfalls of the extracted features were discussed with detail. The obtained results are anticipated to contribute classification process of EMG signal and motion control of powered human arm prosthetics control.

Keywords: assistive devices for neurorehabilitation, electromyography, feature extraction, force estimation, human arm prosthesis

Procedia PDF Downloads 340
113 Validation of Two Field Base Dynamic Balance Tests in the Activation of Selected Hip and Knee Stabilizer Muscles

Authors: Mariam A. Abu-Alim

Abstract:

The purpose of this study was to validate muscle activation amplitudes of two field base dynamic balance tests that are used as strengthen and motor control exercises too in the activation of selected hip and knee stabilizer muscles. Methods: Eighteen college-age females students (21±2 years; 65.6± 8.7 kg; 169.7±8.1 cm) who participated at least for 30 minutes in physical activity most days of the week volunteered. The wireless BIOPAC (MP150, BIOPAC System. Inc, California, USA) surface electromyography system was used to validate the activation of the Gluteus Medius and the Adductor Magnus of hip stabilizer muscles; and the Hamstrings, Quadriceps, and the Gastrocnemius of the knee stabilizer muscles. Surface electrodes (EL 503, BIOPAC, System. Inc) connected to dual wireless EMG BioNormadix Transmitters were place on selected muscles of participants dominate side. Manual muscle testing was performed to obtain the maximal voluntary isometric contraction (MVIC) in which all collected muscle activity data during the three reaching direction: anterior, posteromedial, posterolateral of the Star Excursion Balance Test (SEBT) and the Y-balance Test (YBT) data could be normalized. All participants performed three trials for each reaching direction of the SEBT and the YBT. The domanial leg trial for each participant was selected for analysis which was also the standing leg. Results: the selected hip stabilizer muscles (Gluteus Medius, Adductor Magnus) were both greater than 100%MVIC during the performance of the SEBT and in all three directions. Whereas, selected knee stabilizer muscles had greater activation 0f 100% MVIC and were significantly more activated during the performance of the YBT test in all three reaching directions. The results showed that the posterolateral and the postmedial reaching directions for both dynamic balance tests had greater activation levels and greater than 200%MVIC for all tested muscles expect of the hamstrings. Conclusion: the results of this study showed that the SEBT and the YBT had validated high levels of muscular activity for the hip and the knee stabilizer muscles; which can be used to represent the improvement, strength, control and the decreasing in the injury levels. Since these selected hip and knee stabilizer muscles, represent 35% of all athletic injuries depending on the type of sport.

Keywords: dynamic balance tests, electromyography, hip stabilizer muscles, nee stabilizer muscles

Procedia PDF Downloads 125
112 Health Psychology Intervention: Identifying Early Symptoms in Neurological Disorders

Authors: Simon B. N. Thompson

Abstract:

Early indicator of neurological disease has been proposed by the expanded Thompson Cortisol Hypothesis which suggests that yawning is linked to rises in cortisol levels. Cortisol is essential to the regulation of the immune system and pathological yawning is a symptom of multiple sclerosis (MS). Electromyography activity (EMG) in the jaw muscles typically rises when the muscles are moved – extended or flexed; and yawning has been shown to be highly correlated with cortisol levels in healthy people. It is likely that these elevated cortisol levels are also seen in people with MS. The possible link between EMG in the jaw muscles and rises in saliva cortisol levels during yawning were investigated in a randomized controlled trial of 60 volunteers aged 18-69 years who were exposed to conditions that were designed to elicit the yawning response. Saliva samples were collected at the start and after yawning, or at the end of the presentation of yawning-provoking stimuli, in the absence of a yawn, and EMG data was additionally collected during rest and yawning phases. Hospital Anxiety and Depression Scale, Yawning Susceptibility Scale, General Health Questionnaire, demographic, and health details were collected and the following exclusion criteria were adopted: chronic fatigue, diabetes, fibromyalgia, heart condition, high blood pressure, hormone replacement therapy, multiple sclerosis, and stroke. Significant differences were found between the saliva cortisol samples for the yawners, t (23) = -4.263, p = 0.000, as compared with the non-yawners between rest and post-stimuli, which was non-significant. There were also significant differences between yawners and non-yawners for the EMG potentials with the yawners having higher rest and post-yawning potentials. Significant evidence was found to support the Thompson Cortisol Hypothesis suggesting that rises in cortisol levels are associated with the yawning response. Further research is underway to explore the use of cortisol as a potential diagnostic tool as an assist to the early diagnosis of symptoms related to neurological disorders. Bournemouth University Research & Ethics approval granted: JC28/1/13-KA6/9/13. Professional code of conduct, confidentiality, and safety issues have been addressed and approved in the Ethics submission. Trials identification number: ISRCTN61942768. http://www.controlled-trials.com/isrctn/

Keywords: cortisol, electromyography, neurology, yawning

Procedia PDF Downloads 556
111 Time Estimation of Return to Sports Based on Classification of Health Levels of Anterior Cruciate Ligament Using a Convolutional Neural Network after Reconstruction Surgery

Authors: Zeinab Jafari A., Ali Sharifnezhad B., Mohammad Razi C., Mohammad Haghpanahi D., Arash Maghsoudi

Abstract:

Background and Objective: Sports-related rupture of the anterior cruciate ligament (ACL) and following injuries have been associated with various disorders, such as long-lasting changes in muscle activation patterns in athletes, which might last after ACL reconstruction (ACLR). The rupture of the ACL might result in abnormal patterns of movement execution, extending the treatment period and delaying athletes’ return to sports (RTS). As ACL injury is especially prevalent among athletes, the lengthy treatment process and athletes’ absence from sports are of great concern to athletes and coaches. Thus, estimating safe time of RTS is of crucial importance. Therefore, using a deep neural network (DNN) to classify the health levels of ACL in injured athletes, this study aimed to estimate the safe time for athletes to return to competitions. Methods: Ten athletes with ACLR and fourteen healthy controls participated in this study. Three health levels of ACL were defined: healthy, six-month post-ACLR surgery and nine-month post-ACLR surgery. Athletes with ACLR were tested six and nine months after the ACLR surgery. During the course of this study, surface electromyography (sEMG) signals were recorded from five knee muscles, namely Rectus Femoris (RF), Vastus Lateralis (VL), Vastus Medialis (VM), Biceps Femoris (BF), Semitendinosus (ST), during single-leg drop landing (SLDL) and forward hopping (SLFH) tasks. The Pseudo-Wigner-Ville distribution (PWVD) was used to produce three-dimensional (3-D) images of the energy distribution patterns of sEMG signals. Then, these 3-D images were converted to two-dimensional (2-D) images implementing the heat mapping technique, which were then fed to a deep convolutional neural network (DCNN). Results: In this study, we estimated the safe time of RTS by designing a DCNN classifier with an accuracy of 90 %, which could classify ACL into three health levels. Discussion: The findings of this study demonstrate the potential of the DCNN classification technique using sEMG signals in estimating RTS time, which will assist in evaluating the recovery process of ACLR in athletes.

Keywords: anterior cruciate ligament reconstruction, return to sports, surface electromyography, deep convolutional neural network

Procedia PDF Downloads 47
110 Comparison of EMG Normalization Techniques Recommended for Back Muscles Used in Ergonomics Research

Authors: Saif Al-Qaisi, Alif Saba

Abstract:

Normalization of electromyography (EMG) data in ergonomics research is a prerequisite for interpreting the data. Normalizing accounts for variability in the data due to differences in participants’ physical characteristics, electrode placement protocols, time of day, and other nuisance factors. Typically, normalized data is reported as a percentage of the muscle’s isometric maximum voluntary contraction (%MVC). Various MVC techniques have been recommended in the literature for normalizing EMG activity of back muscles. This research tests and compares the recommended MVC techniques in the literature for three back muscles commonly used in ergonomics research, which are the lumbar erector spinae (LES), latissimus dorsi (LD), and thoracic erector spinae (TES). Six healthy males from a university population participated in this research. Five different MVC exercises were compared for each muscle using the Tringo wireless EMG system (Delsys Inc.). Since the LES and TES share similar functions in controlling trunk movements, their MVC exercises were the same, which included trunk extension at -60°, trunk extension at 0°, trunk extension while standing, hip extension, and the arch test. The MVC exercises identified in the literature for the LD were chest-supported shoulder extension, prone shoulder extension, lat-pull down, internal shoulder rotation, and abducted shoulder flexion. The maximum EMG signal was recorded during each MVC trial, and then the averages were computed across participants. A one-way analysis of variance (ANOVA) was utilized to determine the effect of MVC technique on muscle activity. Post-hoc analyses were performed using the Tukey test. The MVC technique effect was statistically significant for each of the muscles (p < 0.05); however, a larger sample of participants was needed to detect significant differences in the Tukey tests. The arch test was associated with the highest EMG average at the LES, and also it resulted in the maximum EMG activity more often than the other techniques (three out of six participants). For the TES, trunk extension at 0° was associated with the largest EMG average, and it resulted in the maximum EMG activity the most often (three out of six participants). For the LD, participants obtained their maximum EMG either from chest-supported shoulder extension (three out of six participants) or prone shoulder extension (three out of six participants). Chest-supported shoulder extension, however, had a larger average than prone shoulder extension (0.263 and 0.240, respectively). Although all the aforementioned techniques were superior in their averages, they did not always result in the maximum EMG activity. If an accurate estimate of the true MVC is desired, more than one technique may have to be performed. This research provides additional MVC techniques for each muscle that may elicit the maximum EMG activity.

Keywords: electromyography, maximum voluntary contraction, normalization, physical ergonomics

Procedia PDF Downloads 168
109 Integrating Wearable-Textiles Sensors and IoT for Continuous Electromyography Monitoring

Authors: Bulcha Belay Etana, Benny Malengier, Debelo Oljira, Janarthanan Krishnamoorthy, Lieva Vanlangenhove

Abstract:

Electromyography (EMG) is a technique used to measure the electrical activity of muscles. EMG can be used to assess muscle function in a variety of settings, including clinical, research, and sports medicine. The aim of this study was to develop a wearable textile sensor for EMG monitoring. The sensor was designed to be soft, stretchable, and washable, making it suitable for long-term use. The sensor was fabricated using a conductive thread material that was embroidered onto a fabric substrate. The sensor was then connected to a microcontroller unit (MCU) and a Wi-Fi-enabled module. The MCU was programmed to acquire the EMG signal and transmit it wirelessly to the Wi-Fi-enabled module. The Wi-Fi-enabled module then sent the signal to a server, where it could be accessed by a computer or smartphone. The sensor was able to successfully acquire and transmit EMG signals from a variety of muscles. The signal quality was comparable to that of commercial EMG sensors. The development of this sensor has the potential to improve the way EMG is used in a variety of settings. The sensor is soft, stretchable, and washable, making it suitable for long-term use. This makes it ideal for use in clinical settings, where patients may need to wear the sensor for extended periods of time. The sensor is also small and lightweight, making it ideal for use in sports medicine and research settings. The data for this study was collected from a group of healthy volunteers. The volunteers were asked to perform a series of muscle contractions while the EMG signal was recorded. The data was then analyzed to assess the performance of the sensor. The EMG signals were analyzed using a variety of methods, including time-domain analysis and frequency-domain analysis. The time-domain analysis was used to extract features such as the root mean square (RMS) and average rectified value (ARV). The frequency-domain analysis was used to extract features such as the power spectrum. The question addressed by this study was whether a wearable textile sensor could be developed that is soft, stretchable, and washable and that can successfully acquire and transmit EMG signals. The results of this study demonstrate that a wearable textile sensor can be developed that meets the requirements of being soft, stretchable, washable, and capable of acquiring and transmitting EMG signals. This sensor has the potential to improve the way EMG is used in a variety of settings.

Keywords: EMG, electrode position, smart wearable, textile sensor, IoT, IoT-integrated textile sensor

Procedia PDF Downloads 45
108 Comprehensive Analysis of Electrohysterography Signal Features in Term and Preterm Labor

Authors: Zhihui Liu, Dongmei Hao, Qian Qiu, Yang An, Lin Yang, Song Zhang, Yimin Yang, Xuwen Li, Dingchang Zheng

Abstract:

Premature birth, defined as birth before 37 completed weeks of gestation is a leading cause of neonatal morbidity and mortality and has long-term adverse consequences for health. It has recently been reported that the worldwide preterm birth rate is around 10%. The existing measurement techniques for diagnosing preterm delivery include tocodynamometer, ultrasound and fetal fibronectin. However, they are subjective, or suffer from high measurement variability and inaccurate diagnosis and prediction of preterm labor. Electrohysterography (EHG) method based on recording of uterine electrical activity by electrodes attached to maternal abdomen, is a promising method to assess uterine activity and diagnose preterm labor. The purpose of this study is to analyze the difference of EHG signal features between term labor and preterm labor. Free access database was used with 300 signals acquired in two groups of pregnant women who delivered at term (262 cases) and preterm (38 cases). Among them, EHG signals from 38 term labor and 38 preterm labor were preprocessed with band-pass Butterworth filters of 0.08–4Hz. Then, EHG signal features were extracted, which comprised classical time domain description including root mean square and zero-crossing number, spectral parameters including peak frequency, mean frequency and median frequency, wavelet packet coefficients, autoregression (AR) model coefficients, and nonlinear measures including maximal Lyapunov exponent, sample entropy and correlation dimension. Their statistical significance for recognition of two groups of recordings was provided. The results showed that mean frequency of preterm labor was significantly smaller than term labor (p < 0.05). 5 coefficients of AR model showed significant difference between term labor and preterm labor. The maximal Lyapunov exponent of early preterm (time of recording < the 26th week of gestation) was significantly smaller than early term. The sample entropy of late preterm (time of recording > the 26th week of gestation) was significantly smaller than late term. There was no significant difference for other features between the term labor and preterm labor groups. Any future work regarding classification should therefore focus on using multiple techniques, with the mean frequency, AR coefficients, maximal Lyapunov exponent and the sample entropy being among the prime candidates. Even if these methods are not yet useful for clinical practice, they do bring the most promising indicators for the preterm labor.

Keywords: electrohysterogram, feature, preterm labor, term labor

Procedia PDF Downloads 529
107 Bioarm, a Prothesis without Surgery

Authors: J. Sagouis, A. Chamel, E. Carre, C. Casasreales, G. Rudnik, M. Cerdan

Abstract:

Robotics provides answers to amputees. The most expensive solutions surgically connect the prosthesis to nerve endings. There are also several types of non-invasive technologies that recover nerve messages passing through the muscles. After analyzing these messages, myoelectric prostheses perform the desired movement. The main goal is to avoid all surgeries, which can be heavy and offer cheaper alternatives. For an amputee, we use valid muscles to recover the electrical signal involved in a muscle movement. EMG sensors placed on the muscle allows us to measure a potential difference, which our program transforms into control for a robotic arm with two degrees of freedom. We have shown the feasibility of non-invasive prostheses with two degrees of freedom. Signal analysis and an increase in degrees of freedom is still being improved.

Keywords: prosthesis, electromyography (EMG), robotic arm, nerve message

Procedia PDF Downloads 228
106 An Agent-Based Modeling and Simulation of Human Muscle

Authors: Sina Saadati, Mohammadreza Razzazi

Abstract:

In this article, we have tried to present an agent-based model of human muscle. A suitable model of muscle is necessary for the analysis of mankind's movements. It can be used by clinical researchers who study the influence of motion sicknesses, like Parkinson's disease. It is also useful in the development of a prosthesis that receives the electromyography signals and generates force as a reaction. Since we have focused on computational efficiency in this research, the model can compute the calculations very fast. As far as it concerns prostheses, the model can be known as a charge-efficient method. In this paper, we are about to illustrate an agent-based model. Then, we will use it to simulate the human gait cycle. This method can also be done reversely in the analysis of gait in motion sicknesses.

Keywords: agent-based modeling and simulation, human muscle, gait cycle, motion sickness

Procedia PDF Downloads 79
105 Interrelationship between Quadriceps' Activation and Inhibition as a Function of Knee-Joint Angle and Muscle Length: A Torque and Electro and Mechanomyographic Investigation

Authors: Ronald Croce, Timothy Quinn, John Miller

Abstract:

Incomplete activation, or activation failure, of motor units during maximal voluntary contractions is often referred to as muscle inhibition (MI), and is defined as the inability of the central nervous system to maximally drive a muscle during a voluntary contraction. The purpose of the present study was to assess the interrelationship amongst peak torque (PT), muscle inhibition (MI; incomplete activation of motor units), and voluntary muscle activation (VMA) of the quadriceps’ muscle group as a function of knee angle and muscle length during maximal voluntary isometric contractions (MVICs). Nine young adult males (mean + standard deviation: age: 21.58 + 1.30 years; height: 180.07 + 4.99 cm; weight: 89.07 + 7.55 kg) performed MVICs in random order with the knee at 15, 55, and 95° flexion. MI was assessed using the interpolated twitch technique and was estimated by the amount of additional knee extensor PT evoked by the superimposed twitch during MVICs. Voluntary muscle activation was estimated by root mean square amplitude electromyography (EMGrms) and mechanomyography (MMGrms) of agonist (vastus medialis [VM], vastus lateralis [VL], and rectus femoris [RF]) and antagonist (biceps femoris ([BF]) muscles during MVICs. Data were analyzed using separate repeated measures analysis of variance. Results revealed a strong dependency of quadriceps’ PT (p < 0.001), MI (p < 0.001) and MA (p < 0.01) on knee joint position: PT was smallest at the most shortened muscle position (15°) and greatest at mid-position (55°); MI and MA were smallest at the most shortened muscle position (15°) and greatest at the most lengthened position (95°), with the RF showing the greatest change in MA. It is hypothesized that the ability to more fully activate the quadriceps at short compared to longer muscle lengths (96% contracted at 15°; 91% at 55°; 90% at 95°) might partly compensate for the unfavorable force-length mechanics at the more extended position and consequent declines in VMA (decreases in EMGrms and MMGrms muscle amplitude during MVICs) and force production (PT = 111-Nm at 15°, 217-NM at 55°, 199-Nm at 95°). Biceps femoris EMG and MMG data showed no statistical differences (p = 0.11 and 0.12, respectively) at joint angles tested, although there were greater values at the extended position. Increased BF muscle amplitude at this position could be a mechanism by which anterior shear and tibial rotation induced by high quadriceps’ activity are countered. Measuring and understanding the degree to which one sees MI and VMA in the QF muscle has particular clinical relevance because different knee-joint disorders, such ligament injuries or osteoarthritis, increase levels of MI observed and markedly reduced the capability of full VMA.

Keywords: electromyography, interpolated twitch technique, mechanomyography, muscle activation, muscle inhibition

Procedia PDF Downloads 312
104 A Self-Adaptive Stimulus Artifacts Removal Approach for Electrical Stimulation Based Muscle Rehabilitation

Authors: Yinjun Tu, Qiang Fang, Glenn I. Matthews, Shuenn-Yuh Lee

Abstract:

This paper reports an efficient and rigorous self-adaptive stimulus artifacts removal approach for a mixed surface EMG (Electromyography) and stimulus signal during muscle stimulation. The recording of EMG and the stimulation of muscles were performing simultaneously. It is difficult to generate muscle fatigue feature from the mixed signal, which can be further used in closed loop system. A self-adaptive method is proposed in this paper, the stimulation frequency was calculated and verified firstly. Then, a mask was created based on this stimulation frequency to remove the undesired stimulus. 20 EMG signal recordings were analyzed, and the ANOVA (analysis of variance) approach illustrated that the decreasing trend of median power frequencies was successfully generated from the 'cleaned' EMG signal.

Keywords: EMG, FES, stimulus artefacts, self-adaptive

Procedia PDF Downloads 371
103 An Ergonomic Handle Design for Instruments in Laparoscopic Surgery

Authors: Ramon Sancibrian, Carlos Redondo-Figuero, Maria C. Gutierrez-Diez, Esther G. Sarabia, Maria A. Benito-Gonzalez, Jose C. Manuel-Palazuelos

Abstract:

In this paper, the design and evaluation of a handle for laparoscopic surgery is presented. The design of the handle is based on ergonomic principles and tries to avoid awkward postures for surgeons. The handle combines the so-called power-grip and accurate-grip in order to provide strength and accuracy in the performance of surgery. The handle is tested using both objective and subjective approaches. The objective approach uses motion capture techniques to obtain the angles of forearm, arm, wrist and hand. The muscular effort is obtained with electromyography electrodes. On the other hand, a subjective survey has been carried out using questionnaires. Results confirm that the handle is preferred by the majority of the surgeons.

Keywords: laparoscopic surgery, ergonomics, mechanical design, biomechanics

Procedia PDF Downloads 471
102 Intelligent Human Pose Recognition Based on EMG Signal Analysis and Machine 3D Model

Authors: Si Chen, Quanhong Jiang

Abstract:

In the increasingly mature posture recognition technology, human movement information is widely used in sports rehabilitation, human-computer interaction, medical health, human posture assessment, and other fields today; this project uses the most original ideas; it is proposed to use the collection equipment for the collection of myoelectric data, reflect the muscle posture change on a degree of freedom through data processing, carry out data-muscle three-dimensional model joint adjustment, and realize basic pose recognition. Based on this, bionic aids or medical rehabilitation equipment can be further developed with the help of robotic arms and cutting-edge technology, which has a bright future and unlimited development space.

Keywords: pose recognition, 3D animation, electromyography, machine learning, bionics

Procedia PDF Downloads 47
101 Use of Misoprostol in Pregnancy Termination in the Third Trimester: Oral versus Vaginal Route

Authors: Saimir Cenameri, Arjana Tereziu, Kastriot Dallaku

Abstract:

Introduction: Intra-uterine death is a common problem in obstetrical practice, and can lead to complications if left to resolve spontaneously. The cervix is unprepared, making inducing of labor difficult. Misoprostol is a synthetic prostaglandin E1 analogue, inexpensive, and is presented valid thanks to its ability to bring about changes in the cervix that lead to the induction of uterine contractions. Misoprostol is quickly absorbed when taken orally, resulting in high initial peak serum concentrations compared with the vaginal route. The vaginal misoprostol peak serum concentration is not as high and demonstrates a more gradual serum concentration decline. This is associated with many benefits for the patient; fast induction of labor; smaller doses; and fewer side effects (dose-depended). Mostly it has been used the regime of 50 μg/4 hour, with a high percentage of success and limited side effects. Objective: Evaluation of the efficiency of the use of oral and vaginal misoprostol in inducing labor, and comparing it with its use not by a previously defined protocol. Methods: Participants in this study included patients at U.H.O.G. 'Koco Gliozheni', Tirana from April 2004-July 2006, presenting with an indication for inducing labor in the third trimester for pregnancy termination. A total of 37 patients were randomly admitted for birth inducing activity, according to protocol (26), oral or vaginal protocol (10 vs. 16), and a control group (11), not subject to the protocol, was created. Oral or vaginal misoprostol was administered at a dose of 50 μg/4 h, while the fourth group participants were treated individually by the members of the medical staff. The main result of interest was the time between induction of labor to birth. Kruskal-Wallis test was used to compare the average age, parity, women weight, gestational age, Bishop's score, the size of the uterus and weight of the fetus between the four groups in the study. The Fisher exact test was used to compare day-stay and causes in the four groups. Mann-Whitney test was used to compare the time of the expulsion and the number of doses between oral and vaginal group. For all statistical tests used, the value of P ≤ 0.05 was considered statistically significant. Results: The four groups were comparable with regard to woman age and weight, parity, abortion indication, Bishop's score, fetal weight and the gestational age. There was significant difference in the percentage of deliveries within 24 hours. The average time from induction to birth per route (vaginal, oral, according to protocol and not according to the protocol) was respectively; 10.43h; 21.10h; 15.77h, 21.57h. There was no difference in maternal complications in groups. Conclusions: Use of vaginal misoprostol for inducing labor in the third trimester for termination of pregnancy appears to be more effective than the oral route, and even more to uses not according to the protocols approved before, where complications are greater and unjustified.

Keywords: inducing labor, misoprostol, pregnancy termination, third trimester

Procedia PDF Downloads 153
100 Exploiting Kinetic and Kinematic Data to Plot Cyclograms for Managing the Rehabilitation Process of BKAs by Applying Neural Networks

Authors: L. Parisi

Abstract:

Kinematic data wisely correlate vector quantities in space to scalar parameters in time to assess the degree of symmetry between the intact limb and the amputated limb with respect to a normal model derived from the gait of control group participants. Furthermore, these particular data allow a doctor to preliminarily evaluate the usefulness of a certain rehabilitation therapy. Kinetic curves allow the analysis of ground reaction forces (GRFs) to assess the appropriateness of human motion. Electromyography (EMG) allows the analysis of the fundamental lower limb force contributions to quantify the level of gait asymmetry. However, the use of this technological tool is expensive and requires patient’s hospitalization. This research work suggests overcoming the above limitations by applying artificial neural networks.

Keywords: kinetics, kinematics, cyclograms, neural networks, transtibial amputation

Procedia PDF Downloads 420
99 Correlation between Electromyographic and Textural Parameters for Different Textured Indian Foods Using Principal Component Analysis

Authors: S. Rustagi, N. S. Sodhi, B. Dhillon, T. Kaur

Abstract:

The objective of this study was to check whether there is any relationship between electromyographic (EMG) and textural parameters during food texture evaluation. In this study, a total of eighteen mastication variables were measured for entire mastication, per chew mastication and three different stages of mastication (viz. early, middle and late) by EMG for five different foods using eight human subjects. Cluster analysis was used to reduce the number of mastication variables from 18 to 5, so that principal component analysis (PCA) could be applied on them. The PCA further resulted in two meaningful principal components. The principal component scores for each food were measured and correlated with five textural parameters (viz. hardness, cohesiveness, chewiness, gumminess and adhesiveness). Correlation coefficients were found to be statistically significant (p < 0.10) for cohesiveness and adhesiveness while if we reduce the significance level (p < 0.20) then chewiness also showed correlation with mastication parameters.

Keywords: electromyography, mastication, sensory, texture

Procedia PDF Downloads 311
98 The Association of Estrogen Receptor Alpha Xbai Gg Genotype and Severe Preeclampsia

Authors: Saeedeh Salimi, Farzaneh Farajian- Mashhadi, Ehsan Tabatabaei, Mahnaz Shahrakipoor, Minoo Yaghmaei, Mojgan Mokhtari

Abstract:

Purpose: Estrogen receptor-α (ERα) plays an essential role in the adaptation of increased uterine blood flow during gestation. Therefore ERα gene could be a possible candidate for preeclampsia(PE) susceptibility. In the current study, we aimed to investigate the association of the ERα gene polymorphisms and PE in an Iranian population. Methods: One hundred ninety-two pregnant women with PE and 186 normotensive women were genotyped for ERα gene (PvuII and XbaI) polymorphisms by PCR-RFLP method. Results: The frequency of alleles and genotypes of ERα PvuII and XbaI polymorphisms were not different between PE and normotensive control women. However, higher frequency of GG genotype was observed in women with severe PE compared to mild PE (OR, 1.8 [95% CI, 1.1 to 3]; P = 0.02) and in severe PE compared to normotensive women [OR= 1.8(1.1-3), P=0.02] after adjusting for age, ethnicity and primiparity. Conclusions: The GG genotype of ERα XbaI polymorphism could be a genetic risk factor for PE predisposition.

Keywords: estrogen receptor-α, polymorphism, gene, preeclampsia

Procedia PDF Downloads 279
97 Effects of Array Electrode Placement on Identifying Localised Muscle Fatigue

Authors: Mohamed R. Al-Mulla, Bader Al-Bader, Firouz K. Ghaaedi, Francisco Sepulveda

Abstract:

Surface electromyography (sEMG) is utilised in numerous studies on muscle activity. In the beginning, single electrodes were utilised; however, the newest approach is to use an array of electrodes or a grid of electrodes to improve the accuracy of the recorded reading. This research focuses on electrode placement on the biceps brachii, using an array of electrodes placed longitudinal and diagonally on the muscle belly. Trials were conducted on four healthy males, with sEMG signal acquisition from fatiguing isometric contractions. The signal was analysed using the power spectrum density. The separation between the two classes of fatigue (non-fatigue and fatigue) was calculated using the Davies-Bouldin Index (DBI). Results show that higher separability between the fatigue content of the sEMG signal when placed longitudinally, in the same direction as the muscle fibers.

Keywords: array electrodes, biceps brachii, electrode placement, EMG, isometric contractions, muscle fatigue

Procedia PDF Downloads 342
96 Learning Example of a Biomedical Project from a Real Problem of Muscle Fatigue

Authors: M. Rezki, A. Belaidi

Abstract:

This paper deals with a method of learning to solve a real problem in biomedical engineering from a technical study of muscle fatigue. Electromyography (EMG) is a technique for evaluating and recording the electrical activity produced by skeletal muscles (viewpoint: anatomical and physiological). EMG is used as a diagnostics tool for identifying neuromuscular diseases, assessing low-back pain and muscle fatigue in general. In order to study the EMG signal for detecting fatigue in a muscle, we have taken a real problem which touches the tramway conductor the handle bar. For the study, we have used a typical autonomous platform in order to get signals at real time. In our case study, we were confronted with complex problem to do our experiments in a tram. This type of problem is recurring among students. To teach our students the method to solve this kind of problem, we built a similar system. Through this study, we realized a lot of objectives such as making the equipment for simulation, the study of detection of muscle fatigue and especially how to manage a study of biomedical looking.

Keywords: EMG, health platform, conductor’s tram, muscle fatigue

Procedia PDF Downloads 292
95 Macroscopic Study of Reproductive Pathologies in Cows at the Souk-Ahras Communal Slaughterhouse

Authors: Besma Abdeltif, Chebabhi Imen

Abstract:

Introduction: it is important to define the genital pathologies encountered in Algeria in postpartum dairy cows. The objective was to identify the different pathologies of reproduction in cows found at the communal abattoir of Souk Ahras. Materials and Methods: Our study was carried at the communal slaughterhouse of Souk-Ahras on 63 genital tracts were examined macroscopically after slaughter. Results: The results obtained reveal a high frequency of pregnant females (14.28%), most of the gestations were at their beginning. Uterine anomalies ranked first in the genital lesions of the cow (20.37%). The frequencies of these abnormalities are in ascending order: aplasia of the horns = 1.85%, traumatic cervical = 1.85%, cervical tumors = 1.85%, chronic endometritis = 3.70% and Acute endometritis = 11.11%. The ovarian cyst is the most common lesion, with a frequency of 3.70%, followed by smooth ovaries (1.85%). These are single, thin-walled cysts more present on the right ovary than the left ovary. Salpingitis is the only tubal lesion found on 5.55% of the non-pregnant genital tract. Neoformation is the only vaginal lesion identified in this work (1.85%). Conclusion: Our result, in general, conforms to the data of the literature.

Keywords: genital tract, cow, slaughterhouse, pathology

Procedia PDF Downloads 84
94 The Effects of Seat Heights and Obesity on Lower-Limb Joint Kinematics during Sit-To-Stand Movement

Authors: Seungwon Baek, Haeseok Jeong, Haehyun Lee, Woojin Park

Abstract:

The main purpose of this study was to compare obese people to the non-obese in terms of joint kinematics in lower-limb body. The height of chairs was also considered as a design factor. Obese people had a difficulty in sit-to-stand (STS) tasks compared to the non-obese people. High chair heights can make STS task easy and it helps the obese to be more comfortable with STS task in particular. Subjects were instructed to wear inertial measurement unit (IMU) sensors. They perform STS task using chairs of different heights. Joint kinematics and subjective ratings of discomfort were measured. Knee angles of the obese group were greater than that of the non-obese group in normal type. No significant difference in joint kinematics was found in high chair. Interaction effect was found between obesity and height of chair. The results verified the previous research that had suggested a biomechanical model of STS movement. The results can be applied to occupational design for the obese.

Keywords: biomechanics, electromyography, joint kinematics, obesity, sitting, sit-to-stand

Procedia PDF Downloads 277
93 Unpowered Knee Exoskeleton with Compliant Joints for Stair Descent Assistance

Authors: Pengfan Wu, Xiaoan Chen, Ye He, Tianchi Chen

Abstract:

This paper introduces the design of an unpowered knee exoskeleton to assist human walking by redistributing the moment of the knee joint during stair descent (SD). Considering the knee moment varying with the knee joint angle and the work of the knee joint is all negative, the custom-built spring was used to convert negative work into the potential energy of the spring during flexion, and the obtained energy work as assistance during extension to reduce the consumption of lower limb muscles. The human-machine adaptability problem was left by traditional rigid wearable due to the knee involves sliding and rotating without a fixed-axis rotation, and this paper designed the two-direction grooves to follow the human-knee kinematics, and the wire spring provides a certain resistance to the pin in the groove to prevent extra degrees of freedom. The experiment was performed on a normal stair by healthy young wearing the device on both legs with the surface electromyography recorded. The results show that the quadriceps (knee extensor) were reduced significantly.

Keywords: unpowered exoskeleton, stair descent, knee compliant joint, energy redistribution

Procedia PDF Downloads 99
92 Anatomical Features of Internal Pudendal Artery

Authors: Adel Yasky, Waseem Al-Talalwah, Shorok Al Dorazi, Roger Soames

Abstract:

The internal pudendal artery is a standard branch of the anterior division of the internal iliac artery. The current study includes 41 cadavers to investigate the origin and branches of the internal pudendal artery and its clinical significances. The internal pudendal artery arose directly from the anterior division of the internal iliac artery in 48.3% while it arose indirectly in 48.5%. However, the internal pudendal artery arose from the posterior division of internal iliac artery in 1.6%. Moreover, it arose internal iliac artery bifurcation site in 1.6%. Further, the internal pudendal artery supplied the urinary bladder in 17.1%. Also, the internal pudendal artery supplied the rectum 33.5% respectively. It gave uterine and vaginal arteries in 9.4% and 7.8% respectively. Finally, it supplied the sciatic nerve via giving lateral sacral branch in 1.6%. Internists, surgeons and radiologists have to be aware of the variability to decrease iatrogenic injury. Therefore, unnecessary proximal ligation should be avoided at the site of indirect origin of the internal pudendal artery to prevent sciatic neuropathy. Further, intrapelvic bleeding as result of laceration of internal pudendal branches during hysterectomy, prostatectomy or proctectomy should be expected. Therefore, this study increases the awareness of surgeons leading to minimize iatrogenic faults,

Keywords: internal pudendal artery, inferior gluteal artery, superior gluteal artery, internal iliac artery, impotence, decreased libido

Procedia PDF Downloads 326
91 Metastatic Invasive Lobular Cancer Presenting as a Cervical Polyp

Authors: Sally Shepherd, Craig Murphy

Abstract:

Introduction: The uterus or cervix are unusual locations as metastatic sites for cancers. It is further unusual for it to be a site of metastasis, whilst the primary malignancy remains occult. Case Report: A 63-year-old female with three months of altered bowel habits underwent a CT scan of the abdomen and pelvis, revealing a bulky uterus and left ovary, nonspecific colonic thickening, and diffuse peritoneal changes. She underwent colposcopy, which revealed a large endocervical polyp that was excised, revealing strongly hormone-positive metastatic invasive lobular breast cancer. She subsequently underwent a PET scan, which showed moderately diffuse activity in the cervix and left adnexa. Breast examination was unremarkable, and screening mammography, ultrasound, and MRI of the breast did not identify any lesions. Her blood tests revealed a Ca 15-3 of 934, CA-125 of 220, and CEA of 27. She was commenced on letrozole and ribociclib with an improvement in her symptoms. Conclusion: It is rare for occult breast cancer to be established and diagnosed by pelvic imaging and biopsy. Suspicion of uterine or cervical metastasis should be heightened in patients with an active or past history of breast cancer.

Keywords: occult breast cancer, cervical metastasis, invasive lobular carcinoma, metastasis

Procedia PDF Downloads 97
90 Development of a Real-Time Brain-Computer Interface for Interactive Robot Therapy: An Exploration of EEG and EMG Features during Hypnosis

Authors: Maryam Alimardani, Kazuo Hiraki

Abstract:

This study presents a framework for development of a new generation of therapy robots that can interact with users by monitoring their physiological and mental states. Here, we focused on one of the controversial methods of therapy, hypnotherapy. Hypnosis has shown to be useful in treatment of many clinical conditions. But, even for healthy people, it can be used as an effective technique for relaxation or enhancement of memory and concentration. Our aim is to develop a robot that collects information about user’s mental and physical states using electroencephalogram (EEG) and electromyography (EMG) signals and performs costeffective hypnosis at the comfort of user’s house. The presented framework consists of three main steps: (1) Find the EEG-correlates of mind state before, during, and after hypnosis and establish a cognitive model for state changes, (2) Develop a system that can track the changes in EEG and EMG activities in real time and determines if the user is ready for suggestion, and (3) Implement our system in a humanoid robot that will talk and conduct hypnosis on users based on their mental states. This paper presents a pilot study in regard to the first stage, detection of EEG and EMG features during hypnosis.

Keywords: hypnosis, EEG, robotherapy, brain-computer interface (BCI)

Procedia PDF Downloads 232