129 The Effect of Geographical Differentials of Epidemiological Transition on Health-Seeking Behavior in India

Authors: Sumit Kumar Das, Laishram Ladusingh

Abstract:

Aim: The aim of the study is to examine the differential of epidemiological transition across fifteen agro-climatic zones of India and its effect on health-seeking behavior. Data and Methods: Unit level data on consumption expenditure on health of India from three decadal rounds conducted by National Sample Survey Organization are used for the analysis. These three rounds are 52nd (1995-96), 60th (2004-05) and 71st (2014-15). The age-adjusted prevalence rate for communicable diseases and non-communicable diseases are estimated for fifteen agro-climatic zones of India for three time periods. Bivariate analysis is used to find out determinants of health-seeking behavior. Multilevel logistic regression is used to examine factors effecting on household health-seeking behavior. Result: The prevalence of communicable diseases is increasing in most of the zones of India. Every South Indian zones, Gujarat plains, and lower Gangetic plain are facing the severe attack of dual burden of diseases. Demand for medical advice has increased in southern zones, and east zones, reliance on private healthcare facilities are increasing in most of the zone. Demographic characteristics of the household head have a significant impact on health-seeking behavior. Conclusion: Proper program implementation is required considering the disease prevalence and differential in the pattern of health seeking behavior. Along with initiation and strengthening of programs for non-communicable, existing programs for communicable diseases need to monitor and supervised strictly.

Keywords: agro-climatic zone, epidemiological transition, health-seeking behavior, multilevel regression

Procedia PDF Downloads 149
128 Interaction between Space Syntax and Agent-Based Approaches for Vehicle Volume Modelling

Authors: Chuan Yang, Jing Bie, Panagiotis Psimoulis, Zhong Wang

Abstract:

Modelling and understanding vehicle volume distribution over the urban network are essential for urban design and transport planning. The space syntax approach was widely applied as the main conceptual and methodological framework for contemporary vehicle volume models with the help of the statistical method of multiple regression analysis (MRA). However, the MRA model with space syntax variables shows a limitation in vehicle volume predicting in accounting for the crossed effect of the urban configurational characters and socio-economic factors. The aim of this paper is to construct models by interacting with the combined impact of the street network structure and socio-economic factors. In this paper, we present a multilevel linear (ML) and an agent-based (AB) vehicle volume model at an urban scale interacting with space syntax theoretical framework. The ML model allowed random effects of urban configurational characteristics in different urban contexts. And the AB model was developed with the incorporation of transformed space syntax components of the MRA models into the agents’ spatial behaviour. Three models were implemented in the same urban environment. The ML model exhibit superiority over the original MRA model in identifying the relative impacts of the configurational characters and macro-scale socio-economic factors that shape vehicle movement distribution over the city. Compared with the ML model, the suggested AB model represented the ability to estimate vehicle volume in the urban network considering the combined effects of configurational characters and land-use patterns at the street segment level.

Keywords: space syntax, vehicle volume modeling, multilevel model, agent-based model

Procedia PDF Downloads 106
127 A Multilevel Analysis of Predictors of Early Antenatal Care Visits among Women of Reproductive Age in Benin: 2017/2018 Benin Demographic and Health Survey

Authors: Ebenezer Kwesi Armah-Ansah, Kenneth Fosu Oteng, Esther Selasi Avinu, Eugene Budu, Edward Kwabena Ameyaw

Abstract:

Background: Maternal mortality, particularly in Benin, is a major public health concern in Sub-Saharan Africa. To provide a positive pregnancy experience and reduce maternal morbidities, all pregnant women must get appropriate and timely prenatal support. However, many pregnant women in developing countries, including Benin, begin antenatal care late. There is a paucity of empirical literature on the prevalence and predictors of early antenatal care visits in Benin. As a result, the purpose of this study is to investigate the prevalence and predictors of early antenatal care visits among women of productive age in Benin. Methods: This is a secondary analysis of the 2017/2018 Benin Demographic and Health Survey (BDHS) data. The study involved 6,919 eligible women. Data analysis was conducted using Stata version 14.2 for Mac OS. We adopted a multilevel logistic regression to examine the predictors of early ANC visits in Benin. The results were presented as odds ratios (ORs) associated with 95% confidence intervals (CIs) and p-value <0.05 to determine the significant associations. Results: The prevalence of early ANC visits among pregnant women in Benin was 57.03% [95% CI: 55.41-58.64]. In the final multilevel logistic regression, early ANC visit was higher among women aged 30-34 [aOR=1.60, 95% CI=1.17-2.18] compared to those aged 15-19, women with primary education [aOR=1.22, 95% CI=1.06-142] compared to the non-educated women, women who were covered by health insurance [aOR=3.03, 95% CI=1.35-6.76], women without a big problem in getting the money needed for treatment [aOR=1.31, 95% CI=1.16-1.49], distance to the health facility, not a big problem [aOR=1.23, 95% CI=1.08-1.41], and women whose partners had secondary/higher education [aOR=1.35, 95% CI=1.15-1.57] compared with those who were not covered by health insurance, had big problem in getting money needed for treatment, distance to health facility is a big problem and whose partners had no education respectively. However, women who had four or more births [aOR=0.60, 95% CI=0.48-0.74] and those in Atacora Region [aOR=0.50, 95% CI=0.37-0.68] had lower odds of early ANC visit. Conclusion: This study revealed a relatively high prevalence of early ANC visits among women of reproductive age in Benin. Women's age, educational status of women and their partners, parity, health insurance coverage, distance to health facilities, and region were all associated with early ANC visits among women of reproductive in Benin. These factors ought to be taken into account when developing ANC policies and strategies in order to boost early ANC visits among women in Benin. This will significantly reduce maternal and newborn mortality and help achieve the World Health Organization’s recommendation that all pregnant women should initiate early ANC visits within the first three months of pregnancy.

Keywords: antenatal care, Benin, maternal health, pregnancy, DHS, public health

Procedia PDF Downloads 27
126 Improvising Grid Interconnection Capabilities through Implementation of Power Electronics

Authors: Ashhar Ahmed Shaikh, Ayush Tandon

Abstract:

The swift reduction of fossil fuels from nature has crucial need for alternative energy sources to cater vital demand. It is essential to boost alternative energy sources to cover the continuously increasing demand for energy while minimizing the negative environmental impacts. Solar energy is one of the reliable sources that can generate energy. Solar energy is freely available in nature and is completely eco-friendly, and they are considered as the most promising power generating sources due to their easy availability and other advantages for the local power generation. This paper is to review the implementation of power electronic devices through Solar Energy Grid Integration System (SEGIS) to increase the efficiency. This paper will also concentrate on the future grid infrastructure and various other applications in order to make the grid smart. Development and implementation of a power electronic devices such as PV inverters and power controllers play an important role in power supply in the modern energy economy. Solar Energy Grid Integration System (SEGIS) opens pathways for promising solutions for new electronic and electrical components such as advanced innovative inverter/controller topologies and their functions, economical energy management systems, innovative energy storage systems with equipped advanced control algorithms, advanced maximum-power-point tracking (MPPT) suited for all PV technologies, protocols and the associated communications. In addition to advanced grid interconnection capabilities and features, the new hardware design results in small size, less maintenance, and higher reliability. The SEGIS systems will make the 'advanced integrated system' and 'smart grid' evolutionary processes to run in a better way. Since the last few years, there was a major development in the field of power electronics which led to more efficient systems and reduction of the cost per Kilo-watt. The inverters became more efficient and had reached efficiencies in excess of 98%, and commercial solar modules have reached almost 21% efficiency.

Keywords: solar energy grid integration systems, smart grid, advanced integrated system, power electronics

Procedia PDF Downloads 153
125 Relationship between Physical Activity Level and Functional Movement in 16-years old Schoolchildren: A Multilevel Modelling Approach

Authors: Josip Karuc, Marjeta Mišigoj-Duraković, Goran Marković, Vedran Hadžić, Michael J. Duncan, Hrvoje Podnar, Maroje Sorić

Abstract:

As a part of the CRO-PALS longitudinal study, this investigation aimed to examine the association between different levels of physical activity (PA) and movement quality in 16-years old school children. The total number of participants in this research was 725. Movement quality was assessed via the Functional Movement Screen (FMSTM), and the PA level was estimated using the School Health Action, Planning, and Evaluation System (SHAPES) questionnaire. In addition, body fat and socioeconomic status (SES) were assessed. In order to investigate the association between total FMS score and different levels of PA, multilevel modeling was employed for boys (n=359) and girls (n=366) separately. All models were adjusted for age, body fat, and SES. Among boys, MVPA, MPA, and VPA were not significant predictors of the total FMS score (β=0.000, p=0.78; β=-0.002, p=0.455; β=0.004, p=0.158, respectively). On the contrary, among girls, VPA and MVPA showed significant effects on the total FMS score (β=0.011, p=0.001, β=0.005, p=0.006, respectively). The findings of this research provide evidence that the intensity of PA is a minor but relevant factor in describing the association between PA and movement quality in adolescent girls but not in boys. This means that the PA level does not guarantee optimal functional movement patterns. Therefore, practicing functional movement patterns in an isolated manner and at moderate to vigorous intensity could be beneficial in order to reduce the risk of injury incidence and potential orthopedic abnormalities in later life. This work was supported by the Croatian Science Foundation, grant no: IP-2016-06-9926 and grant no: DOK-2018-01-2328.

Keywords: functional movement screen, fundamental movement patterns, movement quality, pediatric

Procedia PDF Downloads 111
124 Investigating Physician-Induced Demand among Mental Patients in East Azerbaijan, Iran: A Multilevel Approach of Hierarchical Linear Modeling

Authors: Hossein Panahi, Firouz Fallahi, Sima Nasibparast

Abstract:

Background & Aim: Unnecessary growth in health expenditures of developing countries in recent decades, and also the importance of physicians’ behavior in health market, have made the theory of physician-induced demand (PID) as one of the most important issues in health economics. Therefore, the main objective of this study is to investigate the hypothesis of induced demand among mental patients who receive services from either psychologists or psychiatrists in East Azerbaijan province. Methods: Using data from questionnaires in 2020 and employing the theoretical model of Jaegher and Jegers (2000) and hierarchical linear modeling (HLM), this study examines the PID hypothesis of selected psychologists and psychiatrists. The sample size of the study, after removing the questionnaires with missing data, is 45 psychologists and 203 people of their patients, as well as 30 psychiatrists and 160 people of their patients. Results: The results show that, although psychiatrists are ‘profit-oriented physicians’, there is no evidence of inducing unnecessary demand by them (PID), and the difference between the behavior of employers and employee doctors is due to differences in practice style. However, with regard to psychologists, the results indicate that they are ‘profit-oriented’, and there is a PID effect in this sector. Conclusion: According to the results, it is suggested that in order to reduce competition and eliminate the PID effect, the admission of students in the field of psychology should be reduced, patient information on mental illness should be increased, and government monitoring and control over the national health system must be increased.

Keywords: physician-induced demand, national health system, hierarchical linear modeling methods, multilevel modela

Procedia PDF Downloads 108
123 Comparative Analysis of Photovoltaic Systems

Authors: Irtaza M. Syed, Kaameran Raahemifar

Abstract:

This paper presents comparative analysis of photovoltaic systems (PVS) and proposes practical techniques to improve operational efficiency of the PVS. The best engineering and construction practices for PVS are identified and field oriented recommendation are made. Comparative analysis of central and string inverter based, as well as 600 and 1000 VDC PVS are performed. In addition, direct current (DC) and alternating current (AC) photovoltaic (PV) module based systems are compared. Comparison shows that 1000 V DC String Inverters based PVS is the best choice.

Keywords: photovoltaic module, photovoltaic systems, operational efficiency improvement, comparative analysis

Procedia PDF Downloads 450
122 Day-To-Day Variations in Health Behaviors and Daily Functioning: Two Intensive Longitudinal Studies

Authors: Lavinia Flueckiger, Roselind Lieb, Andrea H. Meyer, Cornelia Witthauer, Jutta Mata

Abstract:

Objective: Health behaviors tend to show a high variability over time within the same person. However, most existing research can only assess a snapshot of a person’s behavior and not capture this natural daily variability. Two intensive longitudinal studies examine the variability in health behavior over one academic year and their implications for other aspects of daily life such as affect and academic performance. Can already a single day of increased physical activity, snacking, or improved sleep have beneficial effects? Methods: In two intensive longitudinal studies with up to 65 assessment days over an entire academic year, university students (Study 1: N = 292; Study 2: N = 304) reported sleep quality, physical activity, snacking, positive and negative affect, and learning goal achievement. Results: Multilevel structural equation models showed that on days on which participants reported better sleep quality or more physical activity than usual, they also reported increased positive affect, decreased negative affect, and better learning goal achievement. Higher day-to-day snacking was only associated with increased positive affect. Both, increased day-to-day sleep quality and physical activity were indirectly associated with better learning goal achievement through changes in positive and negative affect; results for snacking were mixed. Importantly, day-to-day sleep quality was a stronger predictor for affect and learning goal achievement than physical activity or snacking. Conclusion: One day of better sleep or more physical activity than usual is associated with improved affect and academic performance. These findings have important implications for low-threshold interventions targeting the improvement of daily functioning.

Keywords: sleep quality, physical activity, snacking, affect, academic performance, multilevel structural equation model

Procedia PDF Downloads 549
121 Multilevel Regression Model - Evaluate Relationship Between Early Years’ Activities of Daily Living and Alzheimer’s Disease Onset Accounting for Influence of Key Sociodemographic Factors Using a Longitudinal Household Survey Data

Authors: Linyi Fan, C.J. Schumaker

Abstract:

Background: Biomedical efforts to treat Alzheimer’s disease (AD) have typically produced mixed to poor results, while more lifestyle-focused treatments such as exercise may fare better than existing biomedical treatments. A few promising studies have indicated that activities of daily life (ADL) may be a useful way of predicting AD. However, the existing cross-sectional studies fail to show how functional-related issues such as ADL in early years predict AD and how social factors influence health either in addition to or in interaction with individual risk factors. This study would helpbetterscreening and early treatments for the elderly population and healthcare practice. The findings have significance academically and practically in terms of creating positive social change. Methodology: The purpose of this quantitative historical, correlational study was to examine the relationship between early years’ ADL and the development of AD in later years. The studyincluded 4,526participantsderived fromRAND HRS dataset. The Health and Retirement Study (HRS) is a longitudinal household survey data set that is available forresearchof retirement and health among the elderly in the United States. The sample was selected by the completion of survey questionnaire about AD and dementia. The variablethat indicates whether the participant has been diagnosed with AD was the dependent variable. The ADL indices and changes in ADL were the independent variables. A four-step multilevel regression model approach was utilized to address the research questions. Results: Amongst 4,526 patients who completed the AD and dementia questionnaire, 144 (3.1%) were diagnosed with AD. Of the 4,526 participants, 3,465 (76.6%) have high school and upper education degrees,4,074 (90.0%) were above poverty threshold. The model evaluatedthe effect of ADL and change in ADL on onset of AD in late years while allowing the intercept of the model to vary by level of education. The results suggested that the only significant predictor of the onset of AD was changes in early years’ ADL (b = 20.253, z = 2.761, p < .05). However, the result of the sensitivity analysis (b = 7.562, z = 1.900, p =.058), which included more control variables and increased the observation period of ADL, are not supported this finding. The model also estimated whether the variances of random effect vary by Level-2 variables. The results suggested that the variances associated with random slopes were approximately zero, suggesting that the relationship between early years’ ADL were not influenced bysociodemographic factors. Conclusion: The finding indicated that an increase in changes in ADL leads to an increase in the probability of onset AD in the future. However, this finding is not support in a broad observation period model. The study also failed to reject the hypothesis that the sociodemographic factors explained significant amounts of variance in random effect. Recommendations were then made for future research and practice based on these limitations and the significance of the findings.

Keywords: alzheimer’s disease, epidemiology, moderation, multilevel modeling

Procedia PDF Downloads 100
120 DC Bus Voltage Ripple Control of Photo Voltaic Inverter in Low Voltage Ride-Trough Operation

Authors: Afshin Kadri

Abstract:

Using Renewable Energy Resources (RES) as a type of DG unit is developing in distribution systems. The connection of these generation units to existing AC distribution systems changes the structure and some of the operational aspects of these grids. Most of the RES requires to power electronic-based interfaces for connection to AC systems. These interfaces consist of at least one DC/AC conversion unit. Nowadays, grid-connected inverters must have the required feature to support the grid under sag voltage conditions. There are two curves in these conditions that show the magnitude of the reactive component of current as a function of voltage drop value and the required minimum time value, which must be connected to the grid. This feature is named low voltage ride-through (LVRT). Implementing this feature causes problems in the operation of the inverter that increases the amplitude of high-frequency components of the injected current and working out of maximum power point in the photovoltaic panel connected inverters are some of them. The important phenomenon in these conditions is ripples in the DC bus voltage that affects the operation of the inverter directly and indirectly. The losses of DC bus capacitors which are electrolytic capacitors, cause increasing their temperature and decreasing its lifespan. In addition, if the inverter is connected to the photovoltaic panels directly and has the duty of maximum power point tracking, these ripples cause oscillations around the operating point and decrease the generating energy. Using a bidirectional converter in the DC bus, which works as a buck and boost converter and transfers the ripples to its DC bus, is the traditional method to eliminate these ripples. In spite of eliminating the ripples in the DC bus, this method cannot solve the problem of reliability because it uses an electrolytic capacitor in its DC bus. In this work, a control method is proposed which uses the bidirectional converter as the fourth leg of the inverter and eliminates the DC bus ripples using an injection of unbalanced currents into the grid. Moreover, the proposed method works based on constant power control. In this way, in addition, to supporting the amplitude of grid voltage, it stabilizes its frequency by injecting active power. Also, the proposed method can eliminate the DC bus ripples in deep voltage drops, which cause increasing the amplitude of the reference current more than the nominal current of the inverter. The amplitude of the injected current for the faulty phases in these conditions is kept at the nominal value and its phase, together with the phase and amplitude of the other phases, are adjusted, which at the end, the ripples in the DC bus are eliminated, however, the generated power decreases.

Keywords: renewable energy resources, voltage drop value, DC bus ripples, bidirectional converter

Procedia PDF Downloads 41
119 Contribution to Improving the DFIG Control Using a Multi-Level Inverter

Authors: Imane El Karaoui, Mohammed Maaroufi, Hamid Chaikhy

Abstract:

Doubly Fed Induction Generator (DFIG) is one of the most reliable wind generator. Major problem in wind power generation is to generate Sinusoidal signal with very low THD on variable speed caused by inverter two levels used. This paper presents a multi-level inverter whose objective is to reduce the THD and the dimensions of the output filter. This work proposes a three-level NPC-type inverter, the results simulation are presented demonstrating the efficiency of the proposed inverter.

Keywords: DFIG, multilevel inverter, NPC inverter, THD, induction machine

Procedia PDF Downloads 205
118 Switched Ultracapacitors for Maximizing Energy Supply

Authors: Nassouh K. Jaber

Abstract:

Supercapacitors (S.C.) are presently attracting attention for driving general purpose (12VDC to 220VAC) inverters in renewable energy systems. Unfortunately, when the voltage of the S.C supplying the inverter reaches the minimal threshold of 7-8VDC the inverter shuts down leaving the remaining 40% of the valuable energy stored inside the ultracapacitor un-usable. In this work a power electronic circuit is proposed which switches 2 banks of supercapacitors from parallel connection when both are fully charged at 14VDC to serial connection when their voltages drop down to 7 volts, thus keeping the inverter working within its operating limits for a longer time and advantageously tapping almost 92% of the stored energy in the supercapacitors.

Keywords: ultra capacitor, switched ultracapacitors, inverter, supercapacitor, parallel connection, serial connection, battery limitation

Procedia PDF Downloads 381
117 Teaching Method for a Classroom of Students at Different Language Proficiency Levels: Content and Language Integrated Learning in a Japanese Culture Classroom

Authors: Yukiko Fujiwara

Abstract:

As a language learning methodology, Content and Language Integrated Learning (CLIL) has become increasingly prevalent in Japan. Most CLIL classroom practice and its research are conducted in EFL fields. However, much less research has been done in the Japanese language learning setting. Therefore, there are still many issues to work out using CLIL in the Japanese language teaching (JLT) setting. it is expected that more research will be conducted on both authentically and academically. Under such circumstances, this is one of the few classroom-based CLIL researches experiments in JLT and aims to find an effective course design for a class with students at different proficiency levels. The class was called ‘Japanese culture A’. This class was offered as one of the elective classes for International exchange students at a Japanese university. The Japanese proficiency level of the class was above the Japanese Language Proficiency Test Level N3. Since the CLIL approach places importance on ‘authenticity’, the class was designed with materials and activities; such as books, magazines, a film and TV show and a field trip to Kyoto. On the field trip, students experienced making traditional Japanese desserts, by receiving guidance directly from a Japanese artisan. Through the course, designated task sheets were used so the teacher could get feedback from each student to grasp what the class proficiency gap was. After reading an article on Japanese culture, students were asked to write down the words they did not understand and what they thought they needed to learn. It helped both students and teachers to set learning goals and work together for it. Using questionnaires and interviews with students, this research examined whether the attempt was effective or not. Essays they wrote in class were also analyzed. The results from the students were positive. They were motivated by learning authentic, natural Japanese, and they thrived setting their own personal goals. Some students were motivated to learn Japanese by studying the language and others were motivated by studying the cultural context. Most of them said they learned better this way; by setting their own Japanese language and culture goals. These results will provide teachers with new insight towards designing class materials and activities that support students in a multilevel CLIL class.

Keywords: authenticity, CLIL, Japanese language and culture, multilevel class

Procedia PDF Downloads 221
116 Simulation Based Performance Comparison of Different Control Methods of ZSI Feeding Industrial Drives

Authors: Parag Nihawan, Ravinder Singh Bhatia, Dinesh Kumar Jain

Abstract:

Industrial drives are source of serious power quality problems. In this, two typical industrial drives have been dealt with, namely, FOC induction motor drives and DTC induction motor drive. The Z-source inverter is an emerging topology of power electronic converters which is capable of buck boost characteristics. The performances of different control methods based Z-source inverters feeding these industrial drives have been investigated, in this work. The test systems have been modeled and simulated in MATLAB/SIMULINK. The results obtained after carrying out these simulations have been used to draw the conclusions.

Keywords: Z-source inverter, total harmonic distortion, direct torque control, field orientation control

Procedia PDF Downloads 550
115 Hypergraph for System of Systems modeling

Authors: Haffaf Hafid

Abstract:

Hypergraphs, after being used to model the structural organization of System of Sytems (SoS) at macroscopic level, has recent trends towards generalizing this powerful representation at different stages of complex system modelling. In this paper, we first describe different applications of hypergraph theory, and step by step, introduce multilevel modeling of SoS by means of integrating Constraint Programming Langages (CSP) dealing with engineering system reconfiguration strategy. As an application, we give an A.C.T Terminal controlled by a set of Intelligent Automated Vehicle.

Keywords: hypergraph model, structural analysis, bipartite graph, monitoring, system of systems, reconfiguration analysis, hypernetwork

Procedia PDF Downloads 459
114 Comprehensive Multilevel Practical Condition Monitoring Guidelines for Power Cables in Industries: Case Study of Mobarakeh Steel Company in Iran

Authors: S. Mani, M. Kafil, E. Asadi

Abstract:

Condition Monitoring (CM) of electrical equipment has gained remarkable importance during the recent years; due to huge production losses, substantial imposed costs and increases in vulnerability, risk and uncertainty levels. Power cables feed numerous electrical equipment such as transformers, motors, and electric furnaces; thus their condition assessment is of a very great importance. This paper investigates electrical, structural and environmental failure sources, all of which influence cables' performances and limit their uptimes; and provides a comprehensive framework entailing practical CM guidelines for maintenance of cables in industries. The multilevel CM framework presented in this study covers performance indicative features of power cables; with a focus on both online and offline diagnosis and test scenarios, and covers short-term and long-term threats to the operation and longevity of power cables. The study, after concisely overviewing the concept of CM, thoroughly investigates five major areas of power quality, Insulation Quality features of partial discharges, tan delta and voltage withstand capabilities, together with sheath faults, shield currents and environmental features of temperature and humidity; and elaborates interconnections and mutual impacts between those areas; using mathematical formulation and practical guidelines. Detection, location, and severity identification methods for every threat or fault source are also elaborated. Finally, the comprehensive, practical guidelines presented in the study are presented for the specific case of Electric Arc Furnace (EAF) feeder MV power cables in Mobarakeh Steel Company (MSC), the largest steel company in MENA region, in Iran. Specific technical and industrial characteristics and limitations of a harsh industrial environment like MSC EAF feeder cable tunnels are imposed on the presented framework; making the suggested package more practical and tangible.

Keywords: condition monitoring, diagnostics, insulation, maintenance, partial discharge, power cables, power quality

Procedia PDF Downloads 195
113 Multilevel Two-Phase Structuring in the Nitrogen Supersaturated AISI316 Stainless Steel

Authors: Tatsuhiko Aizawa, Yohei Suzuki, Tomomi Shiratori

Abstract:

The austenitic stainless steel type AISI316 has been widely utilized as structural members and mold die substrates. The low temperature plasma nitriding has been utilized to harden these AISI316 members, parts, and dies without loss of intrinsic corrosion resistance to AISI316 stainless steels. Formation of CrN precipitates by normal plasma nitriding processes resulted in severe deterioration of corrosion toughness. Most previous studies on this low temperature nitriding of AISI316 only described the lattice expansion of original AISI316 lattices by the occupation of nitrogen interstitial solutes into octahedral vacancy sites, the significant hardening by nitrogen solid solution, and the enhancement of corrosion toughness. In addition to those engineering items, this low temperature nitriding process was characterized by the nitrogen supersaturation and nitrogen diffusion processes. The nitrogen supersaturated zones expanded by the nitrogen solute occupation to octahedral vacancy sites, and the un-nitrided surroundings to these zones were plastically strained to compensate for the mismatch strains across these nitrided and nitrided zones. The microstructure of nitrided AISI316 was refined by this plastic straining. The nitrogen diffusion process was enhanced to transport nitrogen solute atoms through the refined zone boundaries. This synergetic collaboration among the nitrogen supersaturation, the lattice expansion, the plastic straining, and the grain refinement yielded a thick nitrogen supersaturated layer. This synergetic relation was also characterized by the multilevel two-phase structuring. In XRD (X-Ray Diffraction) analysis, the nitrided AISI316 layer had - and -phases with the peak shifts from original lattices. After EBSD (Electron Back Scattering Diffraction) analysis, -grains and -grains homogeneously distributed in the nitrided layer. The scanning transmission electron microscopy (STEM) revealed that g-phase zone is N-poor cluster and a-phase zone is N-rich cluster. This proves that nitrogen supersaturated AISI316 stainless steels have multi-level two-phase structure in a very fine granular system.

Keywords: AISI316 stainless steels, chemical affinity to nitrogen solutes, multi-level two-phase structuring, nitrogen supersaturation

Procedia PDF Downloads 69
112 Control Scheme for Single-Stage Boost Inverter for Grid-Connected Photovoltaic

Authors: Mohammad Reza Ebrahimi, Behnaz Mahdaviani

Abstract:

Increasing renewable sources such photovoltaic are the reason of environmental pollution. Because photovoltaic generates power in low voltage, first, generated power should increase. Usually, distributed generation injects their power to AC-Grid, hence after voltage increasing an inverter is needed to convert DC power to AC power. This results in utilization two series converter that grows cost, complexity, and low efficiency. In this paper a single stage inverter is utilized to boost and invert in one stage. Control of this scheme is easier, and its initial cost decreases comparing to conventional double stage inverters. A simple control scheme is used to control active power as well as minimum total harmonic distortion (THD) in injected current. Simulations in MATLAB demonstrate better outputs comparing with conventional approaches.

Keywords: maximum power point tracking, boost inverter, control strategy, three phase inverter

Procedia PDF Downloads 337
111 Park’s Vector Approach to Detect an Inter Turn Stator Fault in a Doubly Fed Induction Machine by a Neural Network

Authors: Amel Ourici

Abstract:

An electrical machine failure that is not identified in an initial stage may become catastrophic and it may suffer severe damage. Thus, undetected machine faults may cascade in it failure, which in turn may cause production shutdowns. Such shutdowns are costly in terms of lost production time, maintenance costs, and wasted raw materials. Doubly fed induction generators are used mainly for wind energy conversion in MW power plants. This paper presents a detection of an inter turn stator fault in a doubly fed induction machine whose stator and rotor are supplied by two pulse width modulation (PWM) inverters. The method used in this article to detect this fault, is based on Park’s Vector Approach, using a neural network.

Keywords: doubly fed induction machine, PWM inverter, inter turn stator fault, Park’s vector approach, neural network

Procedia PDF Downloads 561
110 Design of CMOS CFOA Based on Pseudo Operational Transconductance Amplifier

Authors: Hassan Jassim Motlak

Abstract:

A novel design technique employing CMOS Current Feedback Operational Amplifier (CFOA) is presented. The feature of consumption whivh has a very low power in designing pseudo-OTA is used to decreasing the total power consumption of the proposed CFOA. This design approach applies pseudo-OTA as input stage cascaded with buffer stage. Moreover, the DC input offset voltage and harmonic distortion (HD) of the proposed CFOA are very low values compared with the conventional CMOS CFOA due to symmetrical input stage. P-Spice simulation results using 0.18µm MIETEC CMOS process parameters using supply voltage of ±1.2V and 50μA biasing current. The P-Spice simulation shows excellent improvement of the proposed CFOA over existing CMOS CFOA. Some of these performance parameters, for example, are DC gain of 62. dB, open-loop gain-bandwidth product of 108 MHz, slew rate (SR+) of +71.2V/µS, THD of -63dB and DC consumption power (PC) of 2mW.

Keywords: pseudo-OTA used CMOS CFOA, low power CFOA, high-performance CFOA, novel CFOA

Procedia PDF Downloads 283
109 Multilevel Gray Scale Image Encryption through 2D Cellular Automata

Authors: Rupali Bhardwaj

Abstract:

Cryptography is the science of using mathematics to encrypt and decrypt data; the data are converted into some other gibberish form, and then the encrypted data are transmitted. The primary purpose of this paper is to provide two levels of security through a two-step process, rather than transmitted the message bits directly, first encrypted it using 2D cellular automata and then scrambled with Arnold Cat Map transformation; it provides an additional layer of protection and reduces the chance of the transmitted message being detected. A comparative analysis on effectiveness of scrambling technique is provided by scrambling degree measurement parameters i.e. Gray Difference Degree (GDD) and Correlation Coefficient.

Keywords: scrambling, cellular automata, Arnold cat map, game of life, gray difference degree, correlation coefficient

Procedia PDF Downloads 341
108 Robust Attitude Control for Agile Satellites with Vibration Compensation

Authors: Jair Servín-Aguilar, Yu Tang

Abstract:

We address the problem of robust attitude tracking for agile satellites under unknown bounded torque disturbances using a double-gimbal variable-speed control-moment gyro (DGVSCMG) driven by a cluster of three permanent magnet synchronous motors (PMSMs). Uniform practical asymptotic stability is achieved at the torque control level first. The desired speed of gimbals and the acceleration of the spin wheel to produce the required torque are then calculated by a velocity-based steering law and tracked at the PMSM speed-control level by designing a speed-tracking controller with compensation for the vibration caused by eccentricity and imbalance due to mechanical imperfection in the DGVSCMG. Uniform practical asymptotic stability of the overall system is ensured by loan relying on the analysis of the resulting cascaded system. Numerical simulations are included to show the performance improvement of the proposed controller.

Keywords: agile satellites, vibration compensation, internal model, stability

Procedia PDF Downloads 86
107 Analysis of Different Space Vector Pulse Width Modulation Techniques for a Five-Phase Inverter

Authors: K. A. Chinmaya, M. Udaya Bhaskar

Abstract:

Multiphase motor drives are now a day considered for numerous applications due to the advantages that they offer when compared to their three-phase counterparts. Proper modeling of inverters and motors are important in devising an appropriate control algorithm. This paper develops a complete modeling of a five-phase inverter and five-phase space vector modulation schemes which can be used for five-phase motor drives. A novel modified algorithm is introduced which enables the sinusoidal output voltages up to certain voltage value. The waveforms of phase to neutral voltage are compared with the different modulation techniques and also different modulation indexes in terms of Low-order Harmonic (LH) voltage of 3rd and 7th present. A detailed performance evolution of existing and newly modified schemes is done in terms of Total Harmonic Distortion (THD).

Keywords: multi-phase drives, space vector modulation, voltage source inverter, low order harmonic voltages, total harmonic distortion

Procedia PDF Downloads 367
106 A Strategy of Direct Power Control for PWM Rectifier Reducing Ripple in Instantaneous Power

Authors: T. Mohammed Chikouche, K. Hartani

Abstract:

Based on the analysis of basic direct torque control, a parallel master slave for four in-wheel permanent magnet synchronous motors (PMSM) fed by two three phase inverters used in electric vehicle is proposed in this paper. A conventional system with multi-inverter and multi-machine comprises a three phase inverter for each machine to be controlled. Another approach consists in using only one three-phase inverter to supply several permanent magnet synchronous machines. A modified direct torque control (DTC) algorithm is used for the control of the bi-machine traction system. Simulation results show that the proposed control strategy is well adapted for the synchronism of this system and provide good speed tracking performance.

Keywords: electric vehicle, multi-machine single-inverter system, multi-machine multi-inverter control, in-wheel motor, master-slave control

Procedia PDF Downloads 190
105 Habits: Theoretical Foundations and a Conceptual Framework on a Managerial Trap and Chance

Authors: K. Piórkowska

Abstract:

The overarching aim of the paper is to incorporate the micro-foundations perspective in strategic management and offering possibilities to bridge the macro–micro divide, to review the concept of habits, as well as to propose research findings and directions in terms of further exploring the habit construct and its impact on higher epistemological level phenomena (for instance organizational routines, which is a domain inherently multilevel in nature). To realize this aim, the following sections have been developed: (1) habits’ origins, (2) habits – cognitive constellations, (3) interrelationships between habits and mental representations, intentions, (4) habits and organizational routines, and (5) habits and routines linkages with adaptation. The conclusions that have been made support recent and current studies linking the level of individual heterogeneous agents with the level of macro (organizational) outcomes.

Keywords: behaviorism, habits, micro-foundations, routines

Procedia PDF Downloads 232
104 BLDC Motor Driven for Solar Photo Voltaic Powered Air Cooling System

Authors: D. Shobha Rani, M. Muralidhar

Abstract:

Solar photovoltaic (SPV) power systems can be employed as electrical power sources to meet the daily residential energy needs of rural areas that have no access to grid systems. In view of this, a standalone SPV powered air cooling system is proposed in this paper, which constitutes a dc-dc boost converter, two voltage source inverters (VSI) connected to two brushless dc (BLDC) motors which are coupled to a centrifugal water pump and a fan blower. A simple and efficient Maximum Power Point Tracking (MPPT) technique based on Silver Mean Method (SMM) is utilized in this paper. The air cooling system is developed and simulated using the MATLAB / Simulink environment considering the dynamic and steady state variation in the solar irradiance.

Keywords: boost converter, solar photovoltaic array, voltage source inverter, brushless DC motor, solar irradiance, maximum power point tracking, silver mean method

Procedia PDF Downloads 244
103 Individual and Contextual Factors Associated with Modern Contraceptive Use among Sexually Active Adolescents and Young Women in Zambia: A Multilevel Analysis

Authors: Chinyama Lukama, Million Phiri, Namuunda Mutombo

Abstract:

Background: Improving access and utilization to high-quality sexual and reproductive health (SRH) information and services, including family planning (FP) commodities, is central to the global developmental agenda of sub-Saharan Africa (SSA). Despite the importance of family planning use in enhancing maternal health outcomes and fertility reduction, the prevalence of adolescents and young women using modern contraception is generally low in SSA. Zambia is one of the countries in Southern Africa with a high prevalence of teenage pregnancies and fertility rates. Despite many initiatives that have been implemented to improve access and demand for family planning commodities, utilization of FP, especially among adolescents and young women, has generally been low. The objective of this research agenda was to better understand the determinants of modern contraceptive use in adolescents and young women in Zambia. This analysis produced findings that will be critical for informing the strengthening of sexual and reproductive health policy strategies aimed at bolstering the provision and use of maternal health services in order to further improve maternal health outcomes in the country. Method: The study used the recent data from the Demographic and Health Survey of 2018. A sample of 3,513 adolescents and young women (ADYW) were included in the analysis. Multilevel logistic regression models were employed to examine the association of individual and contextual factors with modern contraceptive use among adolescents and young women. Results: The prevalence of modern contraception among sexually active ADYW in Zambia was 38.1% [95% CI, 35.9, 40.4]. ADYW who had secondary or higher level education [aOR = 2.16, 95% CI=1.35–3.47], those with exposure to listening to the radio or watching television [aOR = 1.26, 95% CI=1.01–1.57], and those who had decision-making power at household level [aOR = 2.18, 95% CI=1.71–2.77] were more likely to use modern contraceptives. Conversely, strong neighborhood desire for large family size among ADYW [aOR = 0.65 95% CI = 0.47–0.88] was associated with less likelihood to use modern contraceptives. Community access to family planning information through community health worker visits increased the likelihood [aOR = 1.48, 95% CI=1.16–1.91] of using modern contraception among ADYW. Conclusion: The study found that both individual and community factors were key in influencing modern contraceptive use among adolescents and young women in Zambia. Therefore, when designing family planning interventions, the Government of Zambia, through its policymakers and sexual reproductive health program implementers at the Ministry of Health, in collaboration with stakeholders, should consider the community context. There should also be deliberate actions to encourage family planning education through the media.

Keywords: adolescents, young women, modern contraception use, fertility, family planning

Procedia PDF Downloads 62
102 Design, Control and Implementation of 300Wp Single Phase Photovoltaic Micro Inverter for Village Nano Grid Application

Authors: Ramesh P., Aby Joseph

Abstract:

Micro Inverters provide Module Embedded Solution for harvesting energy from small-scale solar photovoltaic (PV) panels. In addition to higher modularity & reliability (25 years of life), the MicroInverter has inherent advantages such as avoidance of long DC cables, eliminates module mismatch losses, minimizes partial shading effect, improves safety and flexibility in installations etc. Due to the above-stated benefits, the renewable energy technology with Solar Photovoltaic (PV) Micro Inverter becomes more widespread in Village Nano Grid application ensuring grid independence for rural communities and areas without access to electricity. While the primary objective of this paper is to discuss the problems related to rural electrification, this concept can also be extended to urban installation with grid connectivity. This work presents a comprehensive analysis of the power circuit design, control methodologies and prototyping of 300Wₚ Single Phase PV Micro Inverter. This paper investigates two different topologies for PV Micro Inverters, based on the first hand on Single Stage Flyback/ Forward PV Micro-Inverter configuration and the other hand on the Double stage configuration including DC-DC converter, H bridge DC-AC Inverter. This work covers Power Decoupling techniques to reduce the input filter capacitor size to buffer double line (100 Hz) ripple energy and eliminates the use of electrolytic capacitors. The propagation of the double line oscillation reflected back to PV module will affect the Maximum Power Point Tracking (MPPT) performance. Also, the grid current will be distorted. To mitigate this issue, an independent MPPT control algorithm is developed in this work to reject the propagation of this double line ripple oscillation to PV side to improve the MPPT performance and grid side to improve current quality. Here, the power hardware topology accepts wide input voltage variation and consists of suitably rated MOSFET switches, Galvanically Isolated gate drivers, high-frequency magnetics and Film capacitors with a long lifespan. The digital controller hardware platform inbuilt with the external peripheral interface is developed using floating point microcontroller TMS320F2806x from Texas Instruments. The firmware governing the operation of the PV Micro Inverter is written in C language and was developed using code composer studio Integrated Development Environment (IDE). In this work, the prototype hardware for the Single Phase Photovoltaic Micro Inverter with Double stage configuration was developed and the comparative analysis between the above mentioned configurations with experimental results will be presented.

Keywords: double line oscillation, micro inverter, MPPT, nano grid, power decoupling

Procedia PDF Downloads 104
101 Multilevel of Factors Affected Optimal Adherence to Antiretroviral Therapy and Viral Suppression amongst HIV-Infected Prisoners in South Ethiopia: A Prospective Cohort Study

Authors: Terefe Fuge, George Tsourtos , Emma Miller

Abstract:

Objectives: Maintaining optimal adherence and viral suppression in people living with HIV (PLWHA) is essential to ensure both preventative and therapeutic benefits of antiretroviral therapy (ART). Prisoners bear a particularly high burden of HIV infection and are highly likely to transmit to others during and after incarceration. However, the level of adherence and viral suppression, as well as its associated factors in incarcerated populations in low-income countries is unknown. This study aimed to determine the prevalence of non-adherence and viral failure, and contributing factors to this amongst prisoners in South Ethiopia. Methods: A prospective cohort study was conducted between June 1, 2019 and July 31, 2020 to compare the level of adherence and viral suppression between incarcerated and non-incarcerated PLWHA. The study involved 74 inmates living with HIV (ILWHA) and 296 non-incarcerated PLWHA. Background information including sociodemographic, socioeconomic, psychosocial, behavioural, and incarceration-related characteristics was collected using a structured questionnaire. Adherence was determined based on participants’ self-report and pharmacy refill records, and plasma viral load measurements which were undertaken within the study period were prospectively extracted to determine viral suppression. Various univariate and multivariate regression models were used to analyse data. Results: Self-reported dose adherence was approximately similar between ILWHA and non-incarcerated PLWHA (81% and 83% respectively), but ILWHA had a significantly higher medication possession ratio (MPR) (89% vs 75%). The prevalence of viral failure (VF) was slightly higher (6%) in ILWHA compared to non-incarcerated PLWHA (4.4%). The overall dose non-adherence (NA) was significantly associated with missing ART appointments, level of satisfaction with ART services, patient’s ability to comply with a specified medication schedule and types of methods used to monitor the schedule. In ILWHA specifically, accessing ART services from a hospital compared to a health centre, an inability to always attend clinic appointments, experience of depression and a lack of social support predicted NA. VF was significantly higher in males, people of age 31-35 years and in those who experienced social stigma, regardless of their incarceration status. Conclusions: This study revealed that HIV-infected prisoners in South Ethiopia were more likely to be non-adherent to doses and so to develop viral failure compared to their non-incarcerated counterparts. A multitude of factors was found to be responsible for this requiring multilevel intervention strategies focusing on the specific needs of prisoners.

Keywords: Adherence , Antiretroviral therapy, Incarceration, South Ethiopia, Viral suppression

Procedia PDF Downloads 95
100 A Study on Unidirectional Analog Output Voltage Inverter for Capacitive Load

Authors: Sun-Ki Hong, Nam-HeeByeon, Jung-Seop Lee, Tae-Sam Kang

Abstract:

For Common R or R-L load to apply arbitrary voltage, the bridge traditional inverters don’t have any difficulties by PWM method. However for driving some piezoelectric actuator, arbitrary voltage not a pulse but a steady voltage should be applied. Piezoelectric load is considered as R-C load and its voltage does not decrease even though the applied voltage decreases. Therefore it needs some special inverter with circuit that can discharge the capacitive energy. Especially for unidirectional arbitrary voltage driving like as sine wave, it becomes more difficult problem. In this paper, a charge and discharge circuit for unidirectional arbitrary voltage driving for piezoelectric actuator is proposed. The circuit has charging and discharging switches for increasing and decreasing output voltage. With the proposed simple circuit, the load voltage can have any unidirectional level with tens of bandwidth because the load voltage can be adjusted by switching the charging and discharging switch appropriately. The appropriateness is proved from the simulation of the proposed circuit.

Keywords: DC-DC converter, analog output voltage, sinusoidal drive, piezoelectric load, discharging circuit

Procedia PDF Downloads 352