Search results for: bladder outlet obstruction
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 480

Search results for: bladder outlet obstruction

390 Support Systems for Vehicle Use

Authors: G. González, J. Ramírez, A. Rubiano

Abstract:

This article describes different patented systems for safe use in vehicles based on GPS technology, speed sensors, gyroscopes, maps, communication systems, and monitors, that inform the driver about traffic jam, obstruction in the road, speed limits, among others. Once the information is analyzed and contrasted to final propose new technical needs to be solved.

Keywords: GPS, information technology, telecommunications, communication networks, gyroscope, environmental pollution

Procedia PDF Downloads 427
389 Rainfall–Runoff Simulation Using WetSpa Model in Golestan Dam Basin, Iran

Authors: M. R. Dahmardeh Ghaleno, M. Nohtani, S. Khaledi

Abstract:

Flood simulation and prediction is one of the most active research areas in surface water management. WetSpa is a distributed, continuous, and physical model with daily or hourly time step that explains precipitation, runoff, and evapotranspiration processes for both simple and complex contexts. This model uses a modified rational method for runoff calculation. In this model, runoff is routed along the flow path using Diffusion-Wave equation which depends on the slope, velocity, and flow route characteristics. Golestan Dam Basin is located in Golestan province in Iran and it is passing over coordinates 55° 16´ 50" to 56° 4´ 25" E and 37° 19´ 39" to 37° 49´ 28"N. The area of the catchment is about 224 km2, and elevations in the catchment range from 414 to 2856 m at the outlet, with average slope of 29.78%. Results of the simulations show a good agreement between calculated and measured hydrographs at the outlet of the basin. Drawing upon Nash-Sutcliffe model efficiency coefficient for calibration periodic model estimated daily hydrographs and maximum flow rate with an accuracy up to 59% and 80.18%, respectively.

Keywords: watershed simulation, WetSpa, stream flow, flood prediction

Procedia PDF Downloads 222
388 Effect of Atmospheric Pressure on the Flow at the Outlet of a Propellant Nozzle

Authors: R. Haoui

Abstract:

The purpose of this work is to simulate the flow at the exit of Vulcan 1 engine of European launcher Ariane 5. The geometry of the propellant nozzle is already determined using the characteristics method. The pressure in the outlet section of the nozzle is less than atmospheric pressure on the ground, causing the existence of oblique and normal shock waves at the exit. During the rise of the launcher, the atmospheric pressure decreases and the shock wave disappears. The code allows the capture of shock wave at exit of nozzle. The numerical technique uses the Flux Vector Splitting method of Van Leer to ensure convergence and avoid the calculation instabilities. The Courant, Friedrichs and Lewy coefficient (CFL) and mesh size level are selected to ensure the numerical convergence. The nonlinear partial derivative equations system which governs this flow is solved by an explicit unsteady numerical scheme by the finite volume method. The accuracy of the solution depends on the size of the mesh and also the step of time used in the discretized equations. We have chosen in this study the mesh that gives us a stationary solution with good accuracy.

Keywords: finite volume, lunchers, nozzles, shock wave

Procedia PDF Downloads 265
387 Pharmacodynamic Interaction between Tamsulosin and Finasteride Treatment on Induced Benign Prostate Hyperplasia in Mice by Using Chou-Talalay Method

Authors: Firas Rashad Al-Samarai

Abstract:

Introduction: Benign prostatic hyperplasia (BPH) is a common condition as men get older. An enlarged prostate gland can cause uncomfortable urinary symptoms, such as blocking the flow of urine out of the bladder. It can also cause bladder, urinary tract, or kidney problems. Objective: to evaluate the efficacy and interaction of tamsulosin with finasteride treatment on induced benign prostate hyperplasia (BPH) in mice. Methods: BPH was induced by subcutaneous injection of testosterone propionate (20 mg/kg) for 30 days. Eighty-five mice were divided into five groups. The first group (G1): twenty-five mice induced BPH treated with tamsulosin orally and divided into five equal subgroups with doses (0.017, 0.052, 0.087, 0. 123, and 0.158) mg/kg, the second group (G2): twenty-five mice induced BPH treated with finasteride orally and divided into five equal subgroups with doses (0.175, 0.527, 0.878, 1.23, and 1.580) mg/kg. the third group (G3): twenty-five mice induced BPH treated with a combination of tamsulosin with finasteride orally, and divided into five equal subgroups with doses (0.0085, 0.0875), (0.026, 0.2635), (0.0435, 0.439) , (0.0615, 0.615) and ( 0.079 , 0.790 ) mg/kg respectively. Fourth group (G4): five mice induced BPH and treated distilled water. Fifth group (G5): five mice were not inducing BPH and without any treatment. Results: The results showed a gradual significant increase in prostate weight % and prostate index % Inhibitions until reached saturation in the last two doses of tamsulosin, finasteride, and combination groups, the maximum effective dose of tamsulosin and finasteride were (0.156) and (1.495) mg/kg respectively. Moreover, the effective dose of the combination (tamsulosin and finasteride) was estimated (0.06876, 0.6876) mg/kg, respectively, as well as the type of interaction was synergism and the value of the combination index was 0.046. Conclusions: We concluded that the combination of tamsulosin with finasteride showed a synergistic effect in BPH treatment by minimizing the side effect of each drug as s result of decreasing the dose of each one.

Keywords: Tamsulosin, Finasteride, combination, BPH

Procedia PDF Downloads 49
386 Impact of Air Pressure and Outlet Temperature on Physicochemical and Functional Properties of Spray-dried Skim Milk Powder

Authors: Adeline Meriaux, Claire Gaiani, Jennifer Burgain, Frantz Fournier, Lionel Muniglia, Jérémy Petit

Abstract:

Spray-drying process is widely used for the production of dairy powders for food and pharmaceuticals industries. It involves the atomization of a liquid feed into fine droplets, which are subsequently dried through contact with a hot air flow. The resulting powders permit transportation cost reduction and shelf life increase but can also exhibit various interesting functionalities (flowability, solubility, protein modification or acid gelation), depending on operating conditions and milk composition. Indeed, particles porosity, surface composition, lactose crystallization, protein denaturation, protein association or crust formation may change. Links between spray-drying conditions and physicochemical and functional properties of powders were investigated by a design of experiment methodology and analyzed by principal component analysis. Quadratic models were developed, and multicriteria optimization was carried out by the use of genetic algorithm. At the time of abstract submission, verification spray-drying trials are ongoing. To perform experiments, milk from dairy farm was collected, skimmed, froze and spray-dried at different air pressure (between 1 and 3 bars) and outlet temperature (between 75 and 95 °C). Dry matter, minerals content and proteins content were determined by standard method. Solubility index, absorption index and hygroscopicity were determined by method found in literature. Particle size distribution were obtained by laser diffraction granulometry. Location of the powder color in the Cielab color space and water activity were characterized by a colorimeter and an aw-value meter, respectively. Flow properties were characterized with FT4 powder rheometer; in particular compressibility and shearing test were performed. Air pressure and outlet temperature are key factors that directly impact the drying kinetics and powder characteristics during spray-drying process. It was shown that the air pressure affects the particle size distribution by impacting the size of droplet exiting the nozzle. Moreover, small particles lead to more cohesive powder and less saturated color of powders. Higher outlet temperature results in lower moisture level particles which are less sticky and can explain a spray-drying yield increase and the higher cohesiveness; it also leads to particle with low water activity because of the intense evaporation rate. However, it induces a high hygroscopicity, thus, powders tend to get wet rapidly if they are not well stored. On the other hand, high temperature provokes a decrease of native serum proteins which is positively correlated to gelation properties (gel point and firmness). Partial denaturation of serum proteins can improve functional properties of powder. The control of air pressure and outlet temperature during the spray-drying process significantly affects the physicochemical and functional properties of powder. This study permitted to better understand the links between physicochemical and functional properties of powder, to identify correlations between air pressure and outlet temperature. Therefore, mathematical models have been developed and the use of genetic algorithm will allow the optimization of powder functionalities.

Keywords: dairy powders, spray-drying, powders functionalities, design of experiment

Procedia PDF Downloads 49
385 PDMS-Free Microfluidic Chips Fabrication and Utilisation for Pulsed Electric Fields Applications

Authors: Arunas Stirke, Neringa Bakute, Gatis Mozolevskis

Abstract:

A technology of microfluidics is an emerging tool in the field of biology, medicine and chemistry. Microfluidic device is also known as ‘lab-on-a-chip’ technology [1]. In moving from macro- to microscale, there is unprecedented control over spatial and temporal gradients and patterns that cannot be captured in conventional Petri dishes and well plates [2]. However, there is not a single standard microfluidic chip designated for all purposes – every different field of studies needs a specific microchip with certain geometries, inlet/outlet, channel depth and other parameters to precisely regulate the required function. Since our group is studying an effect of pulsed electric field (PEF) to the cells, we have manufactured a microfluidic chip designated for high-throughput electroporation of cells. In our microchip, a cell culture chamber is divided into two parallel channels by a membrane, meanwhile electrodes for electroporation are attached to the wall of the channels. Both microchannels have their own inlet and outlet, enabling injection of transfection material separately. Our perspective is to perform electroporation of mammalian cells in two different ways: (1) plasmid and cells are injected in the same microchannel and (2) injected into separate microchannels. Moreover, oxygen and pH sensors are integrated on order to analyse cell viability parameters after PEF treatment.

Keywords: microfluidics, chip, fabrication, electroporation

Procedia PDF Downloads 53
384 Customer Experience Management in Food and Beverage Outlet at Indian School of Business: Methodology and Recommendations

Authors: Anupam Purwar

Abstract:

In conventional consumer product industry, stockouts are taken care by carrying buffer stock to check underserving caused by changes in customer demand, incorrect forecast or variability in lead times. But, for food outlets, the alternate of carrying buffer stock is unviable because of indispensable need to serve freshly cooked meals. Besides, the food outlet being the sole provider has no incentives to reduce stockouts, as they have no fear of losing revenue, gross profit, customers and market share. Hence, innovative, easy to implement and practical ways of addressing the twin problem of long queues and poor customer experience needs to be investigated. Current work analyses the demand pattern of 11 different food items across a routine day. Based on this optimum resource allocation for all food items has been carried out by solving a linear programming problem with cost minimization as the objective. Concurrently, recommendations have been devised to address this demand and supply side problem keeping in mind their practicability. Currently, the recommendations are being discussed and implemented at ISB (Indian School of Business) Hyderabad campus.

Keywords: F&B industry, resource allocation, demand management, linear programming, LP, queuing analysis

Procedia PDF Downloads 113
383 Time to Cure from Obstetric Fistula and Its Associated Factors among Women Admitted to Addis Ababa Hamlin Fistula Hospital, Addis Ababa Ethiopia: A Survival Analysis

Authors: Chernet Mulugeta, Girma Seyoum, Yeshineh Demrew, Kehabtimer Shiferaw

Abstract:

Background: Obstetric fistula (OF) is a serious medical condition that includes an abnormal opening between the vagina and bladder (vesico-vaginal fistula) or the vagina and rectum (recto-vaginal fistula). It is usually caused by prolonged obstructed labour. Despite its serious health and psychosocial consequences, there is a paucity of evidence regarding the time it takes to heal from OF. Objective: The aim of this study was to assess the time to cure from obstetric fistula and its predictors among women admitted to Addis Ababa Hamlin Fistula Hospital, Addis Ababa, Ethiopia. Methodology: An institution-based retrospective cohort study was conducted from January 2015 to December 2020 among a randomly selected 434 women with OF in Addis Ababa Hamlin Fistula Hospital. Data was collected using a structured checklist adapted from a similar study. The open data kit (ODK) collected data was exported and analyzed by using STATA (14.2). Kaplan Meir was used to compare the recovery time from OF. To identify the predictors of OF, a Cox regression model was fitted, and an adjusted hazard ratio with a 95% confidence interval was used to estimate the strength of the associations. Results: The average time to recover from obstetric fistula was 3.95 (95% CI: 3.0-4.6) weeks. About ¾ of the women [72.8% (95% CI - 0.65-1.2)] were physically cured of obstetric fistula. Having secondary education and above [AHR=3.52; 95% CI (1.98, 6.25)] compared to no formal education, having a live birth [AHR=1.64; 95% CI (1.22, 2.21)], having an intact bladder [AHR=2.47; 95% CI (1.1, 5.54)] compared to totally destructed, and having a grade 1 fistula [AHR=1.98; 95% CI (1.19, 3.31)] compared to grade 3 were the significant predictors of shorter time to cure from an obstetric fistula. Conclusion and recommendation: Overall, the proportion of women with OF who were not being cured was unacceptably high. The time it takes for them to recover from the fistula was also extended. It connotes us to work on the identified predictors to improve the time to recovery from OF.

Keywords: time to recovery, obstetric fistula, predictors, Ethiopia

Procedia PDF Downloads 46
382 Investigating Nurses’ Burnout Experiences on TikTok

Authors: Claire Song

Abstract:

Background: TikTok is an emerging social media platform creating an outlet for nurses to express and communicate their nursing experiences and stress related to nursing. Purpose: This study investigates the lived experiences of nursing burnout shared on TikTok. Method: The cross-sectional content analysis examines the video content, format, type, and quantitative indicators, including the number of likes and comments. Results: A total of 35 videos and 18616 comments were examined, published between November 2020 and May 2023. Combined, these 35 videos received 24859 comments and 1159669 of likes. Most of the videos included nurses, and 12 included nurses in professional attire. Three videos included interviewers in the video, but the rest of the videos were self-recorded. Four themes of nurses’ burnout experiences were identified: 1) high-intensity work environment, 2) negative internal perception, 3) culture of nursing work, and 4) poor teamwork experience. Conclusion: This study explored the description of nurses’ burnout experiences via a creative platform. Social media, such as TikTok, is a valuable outlet for healthcare providers to express and share their experiences. Future research might consider using the social media platform to explore coping strategies and resilience in nurses who experienced burnout.

Keywords: burnout, emotional wellbeing, nursing, social media

Procedia PDF Downloads 58
381 Numerical Investigation of the Diffuser: Geometrical Parameters Effect on Flow Characteristics for Diffuser Augmented Wind Turbine

Authors: Hany El Said Fawaz

Abstract:

This study deals with numerical simulation using a commercial package 'ANSYS FLUENT 14.5' for flow characteristics of a flanged diffuser wind turbine. Influence of geometrical parameters such as flange height, diffuser length, and expansion angle on the lift and drag performance were investigated. As the angle of expansion increases, a considerable flow acceleration through the diffuser occur at expansion angle ranged from 0° and 12° due to the presence of undisturbed streamlines. after that flow circulation is developed near the diffuser outlet and increase with increasing expansion angle which causes a negligible effect of expansion angle. The effect of diffuser length on flow behavior shows that when the diffuser length ratio is less than 1.25, flow acceleration is observed and increased with diffuser length ratio. After this value, the flow field at diffuser outlet is characterized by a recirculation zone. The diffuser flange has an impact effect of the flow behavior as a low pressure zone is developed behind the flange, while a high pressure zone is generated in front of it. As the flange height increase, the intensity of both low and high pressure regions increase which tend to accelerate the flow inside the diffuser till flange height ratio reaches to 0.75.

Keywords: wind turbine, flanged diffuser, expansion angle, diffuser length

Procedia PDF Downloads 217
380 Spontaneous Reformation of Dehiscent Frontal Sinus Wall after Endoscopic Removal of Mucocele

Authors: Tan Dexian Arthur, James Wei Ming Kwek, Ian Loh, Lee Tee Sin

Abstract:

Statement of the Problem: Mucoceles most commonly affect the frontal sinus, which results from chronic obstruction of the sinus ostium or cystic dilatation of mucous glands with ductal obstruction. They are known to cause bony erosion of the sinus walls, which can lead to large defects. These defects were typically managed by obliteration or cranialization of the frontal sinus. Although short term outcomes of conservative management of significant posterior table defects from fractures are promising, there have been no studies on the long-term outcomes of large dehiscences in the posterior wall of the frontal sinus. Methodology & Findings : Computed Tomography (CT) Paranasal Sinuses images were analyzed and found complete spontaneous osteogenesis of a large dehiscent frontal sinus posterior wall, secondary to a large mucocele, 9 years from functional endoscopic sinus surgery with the defect managed conservatively. Conclusion & Significance: The dura is well known for its osteogenic properties. Prior studies have showed that dura could induce osteogenesis in cutaneous tissue in the absence of other central nervous system structures. It was also demonstrated that osteogenesis and chondrogenesis were possible in zygomatic fractures by transplanting neonatal dura grafts to the bony defects in rats. Extrapolating from these studies, the authors postulate that the presence of dura beneath the bony deformity of the posterior frontal sinus wall had likely initiated the osteogenesis and restored the bony defect in the patient. In our literature review, we did not find any reports of spontaneous osteogenesis of large frontal sinus defects. While our experience is incidental, it reinforces the osteogenetic potential of an intact dura and further highlights that selected large defects of the posterior wall of the frontal sinus can be conservatively managed.

Keywords: paranasal sinus mucocele, mucocele, osteogenesis, dehiscence

Procedia PDF Downloads 43
379 Dosimetric Dependence on the Collimator Angle in Prostate Volumetric Modulated Arc Therapy

Authors: Muhammad Isa Khan, Jalil Ur Rehman, Muhammad Afzal Khan Rao, James Chow

Abstract:

Purpose: This study investigates the dose-volume variations in planning target volume (PTV) and organs-at-risk (OARs) using different collimator angles for smart arc prostate volumetric modulated arc therapy (VMAT). Awareness of the collimator angle for PTV and OARs sparing is essential for the planner because optimization contains numerous treatment constraints producing a complex, unstable and computationally challenging problem throughout its examination of an optimal plan in a rational time. Materials and Methods: Single arc VMAT plans at different collimator angles varied systematically (0°-90°) were performed on a Harold phantom and a new treatment plan is optimized for each collimator angle. We analyzed the conformity index (CI), homogeneity index (HI), gradient index (GI), monitor units (MUs), dose-volume histogram, mean and maximum doses to PTV. We also explored OARs (e.g. bladder, rectum and femoral heads), dose-volume criteria in the treatment plan (e.g. D30%, D50%, V30Gy and V38Gy of bladder and rectum; D5%,V14Gy and V22Gy of femoral heads), dose-volume histogram, mean and maximum doses for smart arc VMAT at different collimator angles. Results: There was no significance difference found in VMAT optimization at all studied collimator angles. However, if 0.5% accuracy is concerned then collimator angle = 45° provides higher CI and lower HI. Collimator angle = 15° also provides lower HI values like collimator angle 45°. It is seen that collimator angle = 75° is established as a good for rectum and right femur sparing. Collimator angle = 90° and collimator angle = 30° were found good for rectum and left femur sparing respectively. The PTV dose coverage statistics for each plan are comparatively independent of the collimator angles. Conclusion: It is concluded that this study will help the planner to have freedom to choose any collimator angle from (0°-90°) for PTV coverage and select a suitable collimator angle to spare OARs.

Keywords: VMAT, dose-volume histogram, collimator angle, organs-at-risk

Procedia PDF Downloads 480
378 Device for Thermal Depolymerisation of Organic Substrates Prior to Methane Fermentation

Authors: Marcin Dębowski, Mirosław Krzemieniewski, Marcin Zieliński

Abstract:

This publication presents a device designed to depolymerise and structurally change organic substrate, for use in agricultural biogas plants or sewage treatment plants. The presented device consists of a heated tank equipped with an inlet valve for the crude substrate and an outlet valve for the treated substrate. The system also includes a gas conduit, which is at its tip equipped with a high-pressure solenoid valve and a vacuum relief solenoid valve. A conduit behind the high-pressure solenoid valve connects to the vacuum tank equipped with the outlet valve. The substrate introduced into the device is exposed to agents such as high temperature and cavitation produced by abrupt, short-term reduction of pressure within the heated tank. The combined effect of these processes is substrate destruction rate increase of about 20% when compared to using high temperature alone, and about 30% when compared to utilizing only cavitation. Energy consumption is greatly reduced, as the pressure increase is generated by heating the substrate. Thus, there is a 18% reduction of energy consumption when compared to a device designed to destroy substrate through high temperature alone, and a 35% reduction if compared to using cavitation as the only means of destruction.

Keywords: thermal depolymerisation, organic substrate, biogas, pre-treatment

Procedia PDF Downloads 537
377 Energy and Exergy Analyses of Thin-Layer Drying of Pineapple Slices

Authors: Apolinar Picado, Steve Alfaro, Rafael Gamero

Abstract:

Energy and exergy analyses of thin-layer drying of pineapple slices (Ananas comosus L.) were conducted in a laboratory tunnel dryer. Drying experiments were carried out at three temperatures (100, 115 and 130 °C) and an air velocity of 1.45 m/s. The effects of drying variables on energy utilisation, energy utilisation ratio, exergy loss and exergy efficiency were studied. The enthalpy difference of the gas increased as the inlet gas temperature increase. It is observed that at the 75 minutes of the drying process the outlet gas enthalpy achieves a maximum value that is very close to the inlet value and remains constant until the end of the drying process. This behaviour is due to the reduction of the total enthalpy within the system, or in other words, the reduction of the effective heat transfer from the hot gas flow to the vegetable being dried. Further, the outlet entropy exhibits a significant increase that is not only due to the temperature variation, but also to the increase of water vapour phase contained in the hot gas flow. The maximum value of the exergy efficiency curve corresponds to the maximum value observed within the drying rate curves. This maximum value represents the stage when the available energy is efficiently used in the removal of the moisture within the solid. As the drying rate decreases, the available energy is started to be less employed. The exergetic efficiency was directly dependent on the evaporation flux and since the convective drying is less efficient that other types of dryer, it is likely that the exergetic efficiency has relatively low values.

Keywords: efficiency, energy, exergy, thin-layer drying

Procedia PDF Downloads 222
376 Study of Operating Conditions Impact on Physicochemical and Functional Properties of Dairy Powder Produced by Spray-drying

Authors: Adeline Meriaux, Claire Gaiani, Jennifer Burgain, Frantz Fournier, Lionel Muniglia, Jérémy Petit

Abstract:

Spray-drying process is widely used for the production of dairy powders for food and pharmaceuticals industries. It involves the atomization of a liquid feed into fine droplets, which are subsequently dried through contact with a hot air flow. The resulting powders permit transportation cost reduction and shelf life increase but can also exhibit various interesting functionalities (flowability, solubility, protein modification or acid gelation), depending on operating conditions and milk composition. Indeed, particles porosity, surface composition, lactose crystallization, protein denaturation, protein association or crust formation may change. Links between spray-drying conditions and physicochemical and functional properties of powders were investigated by a design of experiment methodology and analyzed by principal component analysis. Quadratic models were developed, and multicriteria optimization was carried out by the use of genetic algorithm. At the time of abstract submission, verification spray-drying trials are ongoing. To perform experiments, milk from dairy farm was collected, skimmed, froze and spray-dried at different air pressure (between 1 and 3 bars) and outlet temperature (between 75 and 95 °C). Dry matter, minerals content and proteins content were determined by standard method. Solubility index, absorption index and hygroscopicity were determined by method found in literature. Particle size distribution were obtained by laser diffraction granulometry. Location of the powder color in the Cielab color space and water activity were characterized by a colorimeter and an aw-value meter, respectively. Flow properties were characterized with FT4 powder rheometer; in particular, compressibility and shearing test were performed. Air pressure and outlet temperature are key factors that directly impact the drying kinetics and powder characteristics during spray-drying process. It was shown that the air pressure affects the particle size distribution by impacting the size of droplet exiting the nozzle. Moreover, small particles lead to more cohesive powder and less saturated color of powders. Higher outlet temperature results in lower moisture level particles which are less sticky and can explain a spray-drying yield increase and the higher cohesiveness; it also leads to particle with low water activity because of the intense evaporation rate. However, it induces a high hygroscopicity, thus, powders tend to get wet rapidly if they are not well stored. On the other hand, high temperature provokes a decrease of native serum proteins, which is positively correlated to gelation properties (gel point and firmness). Partial denaturation of serum proteins can improve functional properties of powder. The control of air pressure and outlet temperature during the spray-drying process significantly affects the physicochemical and functional properties of powder. This study permitted to better understand the links between physicochemical and functional properties of powder to identify correlations between air pressure and outlet temperature. Therefore, mathematical models have been developed, and the use of genetic algorithm will allow the optimization of powder functionalities.

Keywords: dairy powders, spray-drying, powders functionalities, design of experiment

Procedia PDF Downloads 42
375 Epidemiology and Jeopardy Aspect of Febrile Neutropenia Patients by Means of Infectious Maladies

Authors: Pouya Karimi, Ramin Ghasemi Shayan

Abstract:

Conclusions of the sort and setting of observational treatment for immunocompromised patients with fever are confused by the qualities of the hidden disease and the impacts of medications previously got, just as by changing microbiological examples and patterns in sedate obstruction at national and institutional levels. A few frameworks have been proposed to recognize patients who could profit by outpatient anti-infection treatment from patients who require hospitalization. Useful contemplations may choose whether the fundamental checking during the time of neutropenia can be accomplished.

Keywords: microbiology, infectious, neutropenia, epidemiology

Procedia PDF Downloads 127
374 Assessment of Conventional Drinking Water Treatment Plants as Removal Systems of Virulent Microsporidia

Authors: M. A. Gad, A. Z. Al-Herrawy

Abstract:

Microsporidia comprises various pathogenic species can infect humans by means of water. Moreover, chlorine disinfection of drinking-water has limitations against this protozoan pathogen. A total of 48 water samples were collected from two drinking water treatment plants having two different filtration systems (slow sand filter and rapid sand filter) during one year period. Samples were collected from inlet and outlet of each plant. Samples were separately filtrated through nitrocellulose membrane (142 mm, 0.45 µm), then eluted and centrifuged. The obtained pellet from each sample was subjected to DNA extraction, then, amplification using genus-specific primer for microsporidia. Each microsporidia-PCR positive sample was performed by two species specific primers for Enterocytozoon bieneusi and Encephalitozoon intestinalis. The results of the present study showed that the percentage of removal for microsporidia through different treatment processes reached its highest rate in the station using slow sand filters (100%), while the removal by rapid sand filter system was 81.8%. Statistically, the two different drinking water treatment plants (slow and rapid) had significant effect for removal of microsporidia. Molecular identification of microsporidia-PCR positive samples using two different primers for Enterocytozoon bieneusi and Encephalitozoon intestinalis showed the presence of the two pervious species in the inlet water of the two stations, while Encephalitozoon intestinalis was detected in the outlet water only. In conclusion, the appearance of virulent microsporidia in treated drinking water may cause potential health threat.

Keywords: removal, efficacy, microsporidia, drinking water treatment plants, PCR

Procedia PDF Downloads 177
373 Simulation and Assessment of Carbon Dioxide Separation by Piperazine Blended Solutions Using E-NRTL and Peng-Robinson Models: Study of Regeneration Heat Duty

Authors: Arash Esmaeili, Zhibang Liu, Yang Xiang, Jimmy Yun, Lei Shao

Abstract:

A high-pressure carbon dioxide (CO₂) absorption from a specific off-gas in a conventional column has been evaluated for the environmental concerns by the Aspen HYSYS simulator using a wide range of single absorbents and piperazine (PZ) blended solutions to estimate the outlet CO₂ concentration, CO₂ loading, reboiler power supply, and regeneration heat duty to choose the most efficient solution in terms of CO₂ removal and required heat duty. The property package, which is compatible with all applied solutions for the simulation in this study, estimates the properties based on the electrolyte non-random two-liquid (E-NRTL) model for electrolyte thermodynamics and Peng-Robinson equation of state for vapor phase and liquid hydrocarbon phase properties. The results of the simulation indicate that piperazine, in addition to the mixture of piperazine and monoethanolamine (MEA), demands the highest regeneration heat duty compared with other studied single and blended amine solutions, respectively. The blended amine solutions with the lowest PZ concentrations (5wt% and 10wt%) were considered and compared to reduce the cost of the process, among which the blended solution of 10wt%PZ+35wt%MDEA (methyldiethanolamine) was found as the most appropriate solution in terms of CO₂ content in the outlet gas, rich-CO₂ loading, and regeneration heat duty.

Keywords: absorption, amine solutions, aspen HYSYS, CO₂ loading, piperazine, regeneration heat duty

Procedia PDF Downloads 151
372 Mathematical Modelling of Biogas Dehumidification by Using of Counterflow Heat Exchanger

Authors: Staņislavs Gendelis, Andris Jakovičs, Jānis Ratnieks, Aigars Laizāns, Dāvids Vardanjans

Abstract:

Dehumidification of biogas at the biomass plants is very important to provide the energy efficient burning of biomethane at the outlet. A few methods are widely used to reduce the water content in biogas, e.g. chiller/heat exchanger based cooling, usage of different adsorbents like PSA, or the combination of such approaches. A quite different method of biogas dehumidification is offered and analyzed in this paper. The main idea is to direct the flow of biogas from the plant around it downwards; thus, creating additional insulation layer. As the temperature in gas shell layer around the plant will decrease from ~ 38°C to 20°C in the summer or even to 0°C in the winter, condensation of water vapor occurs. The water from the bottom of the gas shell can be collected and drain away. In addition, another upward shell layer is created after the condensate drainage place on the outer side to further reducing heat losses. Thus, counterflow biogas heat exchanger is created around the biogas plant. This research work deals with the numerical modelling of biogas flow, taking into account heat exchange and condensation on cold surfaces. Different kinds of boundary conditions (air and ground temperatures in summer/winter) and various physical properties of constructions (insulation between layers, wall thickness) are included in the model to make it more general and useful for different biogas flow conditions. The complexity of this problem is fact, that the temperatures in both channels are conjugated in case of low thermal resistance between layers. MATLAB programming language is used for multiphysical model development, numerical calculations and result visualization. Experimental installation of a biogas plant’s vertical wall with an additional 2 layers of polycarbonate sheets with the controlled gas flow was set up to verify the modelling results. Gas flow at inlet/outlet, temperatures between the layers and humidity were controlled and measured during a number of experiments. Good correlation with modelling results for vertical wall section allows using of developed numerical model for an estimation of parameters for the whole biogas dehumidification system. Numerical modelling of biogas counterflow heat exchanger system placed on the plant’s wall for various cases allows optimizing of thickness for gas layers and insulation layer to ensure necessary dehumidification of the gas under different climatic conditions. Modelling of system’s defined configuration with known conditions helps to predict the temperature and humidity content of the biogas at the outlet.

Keywords: biogas dehumidification, numerical modelling, condensation, biogas plant experimental model

Procedia PDF Downloads 506
371 The Performance Improvement of Solar Aided Power Generation System by Introducing the Second Solar Field

Authors: Junjie Wu, Hongjuan Hou, Eric Hu, Yongping Yang

Abstract:

Solar aided power generation (SAPG) technology has been proven as an efficient way to make use of solar energy for power generation purpose. In an SAPG plant, a solar field consisting of parabolic solar collectors is normally used to supply the solar heat in order to displace the high pressure/temperature extraction steam. To understand the performance of such a SAPG plant, a new simulation model was developed by the authors recently, in which the boiler was treated, as a series of heat exchangers unlike other previous models. Through the simulations using the new model, it was found the outlet properties of reheated steam, e.g. temperature, would decrease due to the introduction of the solar heat. The changes make the (lower stage) turbines work under off-design condition. As a result, the whole plant’s performance may not be optimal. In this paper, the second solar filed was proposed to increase the inlet temperature of steam to be reheated, in order to bring the outlet temperature of reheated steam back to the designed condition. A 600MW SAPG plant was simulated as a case study using the new model to understand the impact of the second solar field on the plant performance. It was found in the study, the 2nd solar field would improve the plant’s performance in terms of cycle efficiency and solar-to-electricity efficiency by 1.91% and 6.01%. The solar-generated electricity produced by per aperture area under the design condition was 187.96W/m2, which was 26.14% higher than the previous design.

Keywords: solar-aided power generation system, off-design performance, coal-saving performance, boiler modelling, integration schemes

Procedia PDF Downloads 267
370 The Impact of Total Parenteral Nutrition on Pediatric Stem Cell Transplantation and Its Complications

Authors: R. Alramyan, S. Alsalamah, R. Alrashed, R. Alakel, F. Altheyeb, M. Alessa

Abstract:

Background: Nutritional support with total parenteral nutrition (TPN) is usually commenced with hematopoietic stem cell transplantation (HSCT) patients. However, it has its benefits and risks. Complications related to central venous catheter such as infections, and metabolic disturbances, including abnormal liver function, is usually of concern in such patients. Methods: A retrospective charts review of all pediatric patients who underwent HSCT between the period 2015-2018 in a tertiary hospital in Riyadh, Saudi Arabia. Patients' demographics, types of conditioning, type of nutrition, and patients' outcomes were collected. Statistical analysis was conducted using SPSS version 22. Frequencies and percentages were used to describe categorical variables. Mean, and standard deviation were used for continuous variables. A P value of less than 0.05 was considered as statically significant. Results: a total of 162 HSCTs were identified during the period mentioned. Indication of allogenic transplant included hemoglobinopathy in 50 patients (31%), acute lymphoblastic leukemia in 21 patients (13%). TPN was used in 96 patients (59.30%) for a median of 14 days, nasogastric tube feeding (NGT) in 16 (9.90%) patients for a median of 11 days, and 71 of patients (43.80%) were able to tolerate oral feeding. Out of the 96 patients (59.30%) who were dependent on TPN, 64 patients (66.7%) had severe mucositis in comparison to 17 patients (25.8%) who were either on NGT or tolerated oral intake. (P-value= 0.00). Sinusoidal obstruction syndrome (SOS) was seen in 14 patients (14.6%) who were receiving TPN compared to none in non-TPN patients (P=value 0.001). Moreover, majority of patients who had SOS received myeloablative conditioning therapy for non-malignant disease (hemoglobinopathy). However, there were no statistically significant differences in Graft-vs-Host Disease (both acute and chronic), bacteremia, and patient outcome between both groups. Conclusions: Nutritional support using TPN is used in majority of patients, especially post-myeloablative conditioning associated with severe mucositis. TPN was associated with VOD, especially in hemoglobinopathy patients who received myeloablative therapy. This may emphasize on use of preventative measures such as fluid restriction, use of diuretics, or defibrotide in high-risk patients.

Keywords: hematopoeitic stem cell transplant, HSCT, stem cell transplant, sinusoidal obstruction syndrome, total parenteral nutrition

Procedia PDF Downloads 130
369 Kidney Stones in Individuals Living with Diabetes Mellitus at King Abdul-Aziz Medical City - Tertiary Care Center, Jeddah, Saudi Arabia: A Retrospective Cohort Study

Authors: Suhaib Radi, Ibrahim Basem Nafadi, Abdullah Ahmed Alsulami, Nawaf Faisal Halabi, Abdulrhman Abdullah Alsubhi, Sami Wesam Maghrabi, Waleed Saad Alshehri

Abstract:

Background: Kidney stones greatly affect individuals. The range of these effects regarding multiple kidney stone factors (size, presence of obstruction, and modality of treatment) in stone formers with and without diabetes has not been well explored in the literature to the best of the author's knowledge. Our goal is to investigate this unexplored correlation between diabetes and kidney stones by conducting a Cohort retrospective study to precisely evaluate the effects of this condition and the existence of complications in adult individuals with diabetes in Saudi Arabia in comparison to a non-diabetic control group. Methodology: This is a retrospective cohort study aiming to evaluate the range of effects of kidney stones in stone formers in a group of adults diagnosed with type 2 diabetes mellitus and adults without diabetes between 2017 and 2019 in Jeddah, Saudi Arabia. An IRB approval has been granted for this study. The data was analyzed using SPSS. The data was collected from the 1st of December 2022 until the 1st of March 2023. Results: A total of 254 individuals diagnosed with kidney stones were included, 127 of whom were adult individuals with type 2 diabetes, and 127 were non-diabetics. Our study shows that the individuals affected with diabetes were more likely to have larger kidney stones in comparison to individuals without diabetes (13.12 mm vs. 10.53 mm, p-value = 0.03). Moreover, individuals with hypertension and dyslipidemia also had significantly larger stones. On the other hand, no significant difference was found in the presence of obstruction and modality of treatment between the two groups. Conclusion: This study done in Saudi Arabia found that individuals with kidney stones who concurrently had diabetes formed larger kidney stones, and they were also found to have other comorbidities such as HTN, dyslipidemia, obesity, and renal disease. The significance of these findings could assist in the future of primary and secondary prevention of renal stones.

Keywords: kidney stone, type 2 DM, metabolic syndrome, lithotripsy

Procedia PDF Downloads 76
368 Modeling Soil Erosion and Sediment Yield in Geba Catchment, Ethiopia

Authors: Gebremedhin Kiros, Amba Shetty, Lakshman Nandagiri

Abstract:

Soil erosion is a major threat to the sustainability of land and water resources in the catchment and there is a need to identify critical areas of erosion so that suitable conservation measures may be adopted. The present study was taken up to understand the temporal and spatial distribution of soil erosion and daily sediment yield in Geba catchment (5137 km2) located in the Northern Highlands of Ethiopia. Soil and Water Assessment Tool (SWAT) was applied to the Geba catchment using data pertaining to rainfall, climate, soils, topography and land use/land cover (LU/LC) for the historical period 2000-2013. LU/LC distribution in the catchment was characterized using LANDSAT satellite imagery and the GIS-based ArcSWAT version of the model. The model was calibrated and validated using sediment concentration measurements made at the catchment outlet. The catchment was divided into 13 sub-basins and based on estimated soil erosion, these were prioritized on the basis of susceptibility to soil erosion. Model results indicated that the average sediment yield estimated of the catchment was 12.23 tons/ha/yr. The generated soil loss map indicated that a large portion of the catchment has high erosion rates resulting in significantly large sediment yield at the outlet. Steep and unstable terrain, the occurrence of highly erodible soils and low vegetation cover appeared to favor high soil erosion. Results obtained from this study prove useful in adopting in targeted soil and water conservation measures and promote sustainable management of natural resources in the Geba and similar catchments in the region.

Keywords: Ethiopia, Geba catchment, MUSLE, sediment yield, SWAT Model

Procedia PDF Downloads 290
367 Experimental and Numerical Performance Analysis for Steam Jet Ejectors

Authors: Abdellah Hanafi, G. M. Mostafa, Mohamed Mortada, Ahmed Hamed

Abstract:

The steam ejectors are the heart of most of the desalination systems that employ vacuum. The systems that employ low grade thermal energy sources like solar energy and geothermal energy use the ejector to drive the system instead of high grade electric energy. The jet-ejector is used to create vacuum employing the flow of steam or air and using the severe pressure drop at the outlet of the main nozzle. The present work involves developing a one dimensional mathematical model for designing jet-ejectors and transform it into computer code using Engineering Equation solver (EES) software. The model receives the required operating conditions at the inlets and outlet of the ejector as inputs and produces the corresponding dimensions required to reach these conditions. The one-dimensional model has been validated using an existed model working on Abu-Qir power station. A prototype has been designed according to the one-dimensional model and attached to a special test bench to be tested before using it in the solar desalination pilot plant. The tested ejector will be responsible for the startup evacuation of the system and adjusting the vacuum of the evaporating effects. The tested prototype has shown a good agreement with the results of the code. In addition a numerical analysis has been applied on one of the designed geometry to give an image of the pressure and velocity distribution inside the ejector from a side, and from other side, to show the difference in results between the two-dimensional ideal gas model and real prototype. The commercial edition of ANSYS Fluent v.14 software is used to solve the two-dimensional axisymmetric case.

Keywords: solar energy, jet ejector, vacuum, evaporating effects

Procedia PDF Downloads 590
366 A 30 Year Audit of the Vascular Complications of Ports: Permanent Intravascular Access Devices

Authors: S. Kershaw, P. J. Barry, K. Webb

Abstract:

Background: Cystic Fibrosis (CF) is a chronic lung disease where patients have chronic lung infection punctuated by acute exacerbations that require intermittent intravenous (IV) antibiotics during their lives. With time, peripheral venous access can become difficult and limited. Accessing these veins can become arduous, traumatic, painful and unworkable. A permanent intravascular access device or Port is a small device that is inserted into the central venous system that allows the delivery of medicine eliminating the need for peripheral venous access. Ports represent a convenient and efficient method when venous access is required on a permanent basis however they are also associated with significant vascular complications. Superior Vena Cava Obstruction (SVCO) is a rare but significant vascular complication of ports in this setting. Objective: We aimed to look at a single CF centre’s experience of port-related SVCO over a thirty year period. Methods: Retrospective data was extracted using patient’s notes, electronic radiological reports and local databases over a period in excess of 30 years from 1982 to 2014. Results: 13 patients were identified with SVCO as a result of their port. 11 patients had CF (9 female, 2 male), one male patient had Primary Ciliary Dyskinesia and one female patient had severe Asthma. The mean port function was 1532 days (range 110 – 4049) and the mean age at SVCO was 24 years (range 11.1 to 36.5 years). The most common symptoms were facial oedema (n=8, 61.5%) and dilated veins (n=6, 46.2%). 7 patients had their Ports removed after SVCO. 6 patients underwent attempted stenting (46.2%) and 6 did not. 4 out of the 6 who underwent stenting required/had re-intervention. 3 of the 6 patients who underwent stenting had symptom resolution, however, 4 of the 6 patients who were not stented had symptom resolution also. Symptom resolution was not guaranteed with stenting and required re-intervention in two-thirds. Conclusion: This case series represents the experience of one of the longest established CF units in the UK and represents the largest cohort ever reported in the literature.

Keywords: ports, Superior Vena Cava Obstruction, cystic fibrosis, access devices

Procedia PDF Downloads 295
365 Thermal Performance of an Air-Water Heat Exchanger (AWHE) Operating in Groundwater and Hot-Humid Climate

Authors: César Ramírez-Dolores, Jorge Wong-Loya, Jorge Andaverde, Caleb Becerra

Abstract:

Low-depth geothermal energy can take advantage of the use of the subsoil as an air conditioning technique, being used as a passive system or coupled to an active cooling and/or heating system. This source of air conditioning is possible because at a depth less than 10 meters, the subsoil temperature is practically homogeneous and tends to be constant regardless of the climatic conditions on the surface. The effect of temperature fluctuations on the soil surface decreases as depth increases due to the thermal inertia of the soil, causing temperature stability; this effect presents several advantages in the context of sustainable energy use. In the present work, the thermal behavior of a horizontal Air-Water Heat Exchanger (AWHE) is evaluated, and the thermal effectiveness and temperature of the air at the outlet of the prototype immersed in groundwater is experimentally determined. The thermohydraulic aspects of the heat exchanger were evaluated using the Number of Transfer Units-Efficiency (NTU-ε) method under conditions of groundwater flow in a coastal region of sandy soil (southeastern Mexico) and air flow induced by a blower, the system was constructed of polyvinyl chloride (PVC) and sensors were placed in both the exchanger and the water to record temperature changes. The results of this study indicate that when the exchanger operates in groundwater, it shows high thermal gains allowing better heat transfer, therefore, it significantly reduces the air temperature at the outlet of the system, which increases the thermal effectiveness of the system in values > 80%, this passive technique is relevant for building cooling applications and could represent a significant development in terms of thermal comfort for hot locations in emerging economy countries.

Keywords: convection, earth, geothermal energy, thermal comfort

Procedia PDF Downloads 44
364 Rare Case of Three Metachronous Cancers Occurring over the Period of Three Years: Clinical Importance of Investigating Neoplastic Growth Discovered during Follow-Up

Authors: Marin Kanarev, Delyan Stoyanov, Ivanna Popova, Nadezhda Petrova

Abstract:

Thanks to increased survival rates in patients bearing oncological malignancies due to recent developments in anti-cancer therapies and diagnostic techniques, observation of clinical cases of metachronous cancers is more common and can provide more in-depth knowledge of their development and, as a result, help clinicians apply suitable therapy. This unusual case of three metachronous tumors presented the opportunity to follow their occurrence, progression, and treatment thoroughly. A 77-year-old male presented with carcinoma ventriculi of the pylorus region, which was surgically removed via upper subtotal stomach resection, a lateral antecolical gastro-enteroanastomosis, and a subsequent Braun anastomosis. An EOX chemotherapy regimen followed. A CT scan four months later showed no indication of recurrence or dissemination. The same scan, performed as a part of the follow-up plan two years later, showed an indication of neoplastic growth in the urinary bladder. After the patient had been directed to a urologist, the suspicion was confirmed, and the growth was histologically diagnosed as a carcinoma of the urinary bladder. An immunohistochemistry test showed an expression of PDL1 of less than 5%, which resulted in treatment with GemCis chemotherapy regimen that led to full remission. Two years and seven months after the first surgery, a CT scan showed again that the two carcinomas were gone. However, four months later, elevated tumor markers prompted a PET/CT scan, which showed data indicative of recurring neoplastic growth in the region of the stomach cardia. It was diagnosed as an adenocarcinoma infiltrating the esophagus. Preoperative chemotherapy with the ECF regimen was completed in four courses, and a CT scan showed no progression of the disease. In less than a month after therapy, the patient underwent laparotomy, debridement, gastrectomy, and a subsequent mechanical terminal-lateral esophago-jejunoanasthomosis. It was verified that the tumor originated from metastasis from the carcinoma ventriculi, which was located in the pylorus. In conclusion, this case report highlights the importance of patient follow-up and studying recurring neoplastic growth. Despite the absence of symptoms, clinicians should maintain a high level of suspicion when evaluating the patient data and choosing the most suitable therapy.

Keywords: carcinoma, follow-up, metachronous, neoplastic growth, recurrence

Procedia PDF Downloads 65
363 An Integrated CFD and Experimental Analysis on Double-Skin Window

Authors: Sheam-Chyun Lin, Wei-Kai Chen, Hung-Cheng Yen, Yung-Jen Cheng, Yu-Cheng Chen

Abstract:

Result from the constant dwindle in natural resources, the alternative way to reduce the costs in our daily life would be urgent to be found in the near future. As the ancient technique based on the theory of solar chimney since roman times, the double-skin façade are simply composed of two large glass panels in purpose of daylighting and also natural ventilation in the daytime. Double-skin façade is generally installed on the exterior side of buildings as function as the window, so there’s always a huge amount of passive solar energy the façade would receive to induce the airflow every sunny day. Therefore this article imposes a domestic double-skin window for residential usage and attempts to improve the volume flow rate inside the cavity between the panels by the frame geometry design, the installation of outlet guide plate and the solar energy collection system. Note that the numerical analyses are applied to investigate the characteristics of flow field, and the boundary conditions in the simulation are totally based on the practical experiment of the original prototype. Then we redesign the prototype from the knowledge of the numerical results and fluid dynamic theory, and later the experiments of modified prototype will be conducted to verify the simulation results. The velocities at the inlet of each case are increase by 5%, 45% and 15% from the experimental data, and also the numerical simulation results reported 20% improvement in volume flow rate both for the frame geometry design and installation of outlet guide plate.

Keywords: solar energy, double-skin façades, thermal buoyancy, fluid machinery

Procedia PDF Downloads 465
362 Quantitative Analysis of Carcinoembryonic Antigen (CEA) Using Micromechanical Piezoresistive Cantilever

Authors: Meisam Omidi, M. Mirijalili, Mohammadmehdi Choolaei, Z. Sharifi, F. Haghiralsadat, F. Yazdian

Abstract:

In this work, we have used arrays of micromechanical piezoresistive cantilever with different geometries to detect carcinoembryonic antigen (CEA), which is known as an important biomarker associated with various cancers such as the colorectal, lung, breast, pancreatic, and bladder cancer. The sensing principle is based on the surface stress changes induced by antigen–antibody interaction on the microcantilevers surfaces. Different concentrations of CEA in a human serum albumin (HSA) solution were detected as a function of the deflection of the beams. According to the experiments, it was revealed that microcantilevers have surface stress sensitivities in the order of 8 (mJ/m). This matter allows them to detect CEA concentrations as low as 3 ng/mL or 18 pM. This indicates the fact that the self-sensing microcantilever approach is beneficial for pathological tests.

Keywords: micromechanical biosensors, carcinoembryonic antigen (CEA), surface stress

Procedia PDF Downloads 446
361 Etiology and Postnatal Management of Prenatal Hydronephrosis: A Study of Two Teaching Hospitals of Khyber Pakhtunkhwa

Authors: Saima Ali, Liaqat Ali, Nasir Orakzai

Abstract:

Background: Hydronephrosis is the most common abnormal finding in the urinary tract on prenatal screening with Ultrasonography. The prenatal hydronephrosis is a diagnostic dilemma in differentiating between obstructive variant versus physiologic hydronephrosis. The assessment and prompt diagnosis of prenatal hydronephrosis is important because of the fact that untreated obstructive hydronephrosis usually leads to recurrent UTI, Urosepsis, deterioration of renal functions, non-functioning kidneys, and even end-stage renal disease. Objectives: To determine the etiology and outcome of postnatal treatment of children with prenatal hydronephrosis in two teaching hospitals of Khyber Pakhtunkhwa (KPK) Methods: It is a multicentric descriptive study that was conducted in department of Paediatrics in Kuwait teaching hospital Peshawar and Department of Urology in Institute of Kidney Diseases Hayatabad Medical Complex Peshawar from January 2008 till December 2010. Total numbers of 64 neonates were included in the study with the mean follow-up of 14.5 months. All the diagnostic data in prenatal, postnatal data, and operative and non-operative data were collected on structured Proforma and was analyzed on SPSS version 17. Results: Out of 64 patients, 39 (60.9 %) were male while 25 were female. 52 patients had unilateral while 12 patients had bilateral hydronephrosis. Based upon prenatal USG in term of AP diameter, 37 (57 %) patients had mild hydronephrosis (5-10 mm AP diameter), 14 patients had moderate hydronephrosis (10-15 mm AP diameter) while 13 patients had gross hydronephrosis (More than 15mm). Regarding etiology, 44(76 %) patients were labeled as physiologic hydronephrosis, 11 patients (9.3%) with PUJ obstruction, 5 patients with Vesicoureteric reflux (VUR) and 4 patients with posterior urethral valves. Surgery was performed in total of 15 (23.4%) patients that included open Pyeloplasty in 11 patients, Vesicostomy followed by posterior valve fulguration in 4 patients. All the patients of VUR treated medically. The severity in the grade of prenatal hydronephrosis is significantly associated with the need for definitive urological surgery p < 0.005. Ancillary procedures like percutaneous nephrostomy (PCN) were inserted 7 patients. Conclusions: Prenatal hydronephrosis is a common ailment associated with significant morbidity. Physiological Hydronephrosis and VUR can be successfully treated with medical treatment. However obstructive PUJ obstructions and posterior urethral valves require surgical correction with a good success rate.

Keywords: prenatal hydronephrosis, Pelviureteric Junction (PUJ) Obstruction, vesicoureteric reflux, posterior urethral valve, renography

Procedia PDF Downloads 225