Search results for: ICRP adult male voxel phantom
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 3717

Search results for: ICRP adult male voxel phantom

3717 Numerical response of Coaxial HPGe Detector for Skull and Knee measurement

Authors: Pabitra Sahu, M. Manohari, S. Priyadharshini, R. Santhanam, S. Chandrasekaran, B. Venkatraman

Abstract:

Radiation workers of reprocessing plants have a potential for internal exposure due to actinides and fission products. Radionuclides like Americium, lead, Polonium and Europium are bone seekers and get accumulated in the skeletal part. As the major skeletal content is in the skull (13%) and knee (22%), measurements of old intake have to be carried out in the skull and knee. At the Indira Gandhi Centre for Atomic Research, a twin HPGe-based actinide monitor is used for the measurement of actinides present in bone. Efficiency estimation, which is one of the prerequisites for the quantification of radionuclides, requires anthropomorphic phantoms. Such phantoms are very limited. Hence, in this study, efficiency curves for a Twin HPGe-based actinide monitoring system are established theoretically using the FLUKA Monte Carlo method and ICRP adult male voxel phantom. In the case of skull measurement, the detector is placed over the forehead, and for knee measurement, one detector is placed over each knee. The efficiency values of radionuclides present in the knee and skull vary from 3.72E-04 to 4.19E-04 CPS/photon and 5.22E-04 to 7.07E-04 CPS/photon, respectively, for the energy range 17 to 3000keV. The efficiency curves for the measurement are established, and it is found that initially, the efficiency value increases up to 100 keV and then starts decreasing. It is found that the skull efficiency values are 4% to 63% higher than that of the knee, depending on the energy for all the energies except 17.74 keV. The reason is the closeness of the detector to the skull compared to the knee. But for 17.74 keV the efficiency of the knee is more than the skull due to the higher attenuation caused in the skull bones because of its greater thickness. The Minimum Detectable Activity (MDA) for 241Am present in the skull and knee is 9 Bq. 239Pu has a MDA of 950 Bq and 1270 Bq for knee and skull, respectively, for a counting time of 1800 sec. This paper discusses the simulation method and the results obtained in the study.

Keywords: FLUKA Monte Carlo Method, ICRP adult male voxel phantom, knee, Skull.

Procedia PDF Downloads 6
3716 Effect of Sex and Breed on Live Weight of Adult Iranian Pigeons

Authors: Sepehr Moradi, Mehdi Asadi Rad

Abstract:

This study is to evaluate the live weight of adult pigeons to investigate about their sex, race, their mutual effects and some auxiliary variables in 4 races of Kabood, Tizpar, Parvazy, and Namebar. In this paper, 152 pieces of pigeons as 76 male and female pairs with equal age are studied randomly. Then the birds were weighted by a scale with one gram precision. Software was used for statistical analysis. Mean live weight of adult male and female pigeons in 4 races (Kabood, Tizpar, Parvazy and Namebar with (15, 20, 20, 21) and (20, 21, 18, 17) records were, (530±56, 388.75±32, 392±34, 552±48) and (446±34, 342±32, 341±46, 457±57) gr, respectively. Difference weight of adult live of male with female was significant in 1% level (P < 0.01). Difference live weight of male adult pigeon was significant in 5% level (P < 0.05). Different live weight of female adult pigeon between Kabood, Parvazy and Tizpar races were significant in 5% level (P < 0.05) but mean live weight Kabood race with Namebar race and Parvazy with Tizpar were not significant. The results showed that most and least mean live weights belonged to Namebar of the male pigeon race and Parvazy of the female pigeon race.

Keywords: Iranian Native Pigeons, adult weight, live weight, adult pigeons

Procedia PDF Downloads 177
3715 A Simple Algorithm for Real-Time 3D Capturing of an Interior Scene Using a Linear Voxel Octree and a Floating Origin Camera

Authors: Vangelis Drosos, Dimitrios Tsoukalos, Dimitrios Tsolis

Abstract:

We present a simple algorithm for capturing a 3D scene (focused on the usage of mobile device cameras in the context of augmented/mixed reality) by using a floating origin camera solution and storing the resulting information in a linear voxel octree. Data is derived from cloud points captured by a mobile device camera. For the purposes of this paper, we assume a scene of fixed size (known to us or determined beforehand) and a fixed voxel resolution. The resulting data is stored in a linear voxel octree using a hashtable. We commence by briefly discussing the logic behind floating origin approaches and the usage of linear voxel octrees for efficient storage. Following that, we present the algorithm for translating captured feature points into voxel data in the context of a fixed origin world and storing them. Finally, we discuss potential applications and areas of future development and improvement to the efficiency of our solution.

Keywords: voxel, octree, computer vision, XR, floating origin

Procedia PDF Downloads 106
3714 Simulation Of A Renal Phantom Using the MAG 3

Authors: Ati Moncef

Abstract:

We describe in this paper the results of a phantom of dynamics renal with MAG3. Our phantom consisted of (tow shaped of kidneys, 1 liver). These phantoms were scanned with static and dynamic protocols and compared with clinical data. in a normal conditions we use our phantoms it's possible to acquire a renal images when we can be compared with clinical scintigraphy. In conclusion, Renal phantom also can use in the quality control of a renal scintigraphy.

Keywords: Renal scintigraphy, MAG3, Nuclear medicine, Gamma Camera.

Procedia PDF Downloads 375
3713 3D Printed Multi-Modal Phantom Using Computed Tomography and 3D X-Ray Images

Authors: Sung-Suk Oh, Bong-Keun Kang, Sang-Wook Park, Hui-Jin Joo, Jong-Ryul Choi, Seong-Jun Lee, Jeong-Woo Sohn

Abstract:

The imaging phantom is utilized for the verification, evaluation and tuning of the medical imaging device and system. Although it could be costly, 3D printing is an ideal technique for a rapid, customized, multi-modal phantom making. In this article, we propose the multi-modal phantom using 3D printing. First of all, the Dicom images for were measured by CT (Computed Tomography) and 3D X-ray systems (PET/CT and Angio X-ray system of Siemens) and then were analyzed. Finally, the 3D modeling was processed using Dicom images. The 3D printed phantom was scanned by PET/CT and MRI systems and then evaluated.

Keywords: imaging phantom, MRI (Magnetic Resonance Imaging), PET / CT (Positron Emission Tomography / Computed Tomography), 3D printing

Procedia PDF Downloads 549
3712 Durable Phantom Production Identical to Breast Tissue for Use in Breast Cancer Detection Research Studies

Authors: Hayrettin Eroglu, Adem Kara

Abstract:

Recently there has been significant attention given to imaging of the biological tissues via microwave imaging techniques. In this study, a phantom for the test and calibration of Microwave imaging used in detecting unhealthy breast structure or tumors was produced by using sol gel method. The liquid and gel phantoms being used nowadays are not durable due to evaporation and their organic ingredients, hence a new design was proposed. This phantom was fabricated from materials that were widely available (water, salt, gelatin, and glycerol) and was easy to make. This phantom was aimed to be better from the ones already proposed in the literature in terms of its durability and stability. S Parameters of phantom was measured with 1-18 GHz Probe Kit and permittivity was calculated via Debye method in “85070” commercial software. One, three, and five-week measurements were taken for this phantom. Finally, it was verified that measurement results were very close to the real biological tissue measurement results.

Keywords: phantom, breast tissue, cancer, microwave imaging

Procedia PDF Downloads 326
3711 Osteometry of the Long Bones of Adult Chinkara (Gazella bennettii): A Remarkable Example of Sexual Dimorphism

Authors: Salahud Din, Saima Masood, Hafsa Zaneb, Saima Ashraf, Imad Khan

Abstract:

The objective of this study was 1) to measure osteometric parameters of the long bones of the adult Chinkara to obtain baseline data 2) to study sexual dimorphism in the adult Chinkara through osteometry and 3) to estimate body weight from the measurements of greatest length and shaft of the long bones. For this purpose, after taking body measurements of adult Chinkara after mortality, the carcass of adult Chinkara of known sex and age were buried in the locality of the Manglot Wildlife Park and Ungulate Breeding Centre, Nizampur, Pakistan; after a specific period of time, the bones were unearthed. Various osteometric parameters of the humerus, radius, metacarpus, femur, tibia and metatarsal were measured through the digital calliper. Statistically significant (P < 0.05), differences in some of the osteometrical parameters between male and female adult Chinkara were observed. Sexual dimorphism exit between the long bones of male and female adult Chinkara. In both male and female Chinkara value obtained for the estimated body weight from humeral, metacarpal and metatarsal measurements were near to the actual body weight of the adult Chinkara. In conclusion, the present study estimates preliminary data on long bones osteometrics and suggests that the morphometric details of the male and female adult Chinkara have differed morphometrically from each other.

Keywords: body mass measurements, Chinkara, long bones, morphometric, sexual dimorphism

Procedia PDF Downloads 97
3710 Phantom Phenomena in Subjects after Limb Amutation Who Regularly Practice High Intensity Sports

Authors: Jolanta Uszko, Tomasz Wloch, Aneta Pirowska, Roman Nowobilski

Abstract:

Introduction: Phantom phenomena are often reported by subjects who have undergone limb amputation. Mostly, patients feel the amputated part of the limb as if it was still attached to the body. Two types of phantom phenomena: painless (phantom sensation) and painful (phantom pain) were described. Triggers of phantom sensations and phantom pain, as well as fully effective treatment, have not been clearly described yet. Purpose: To assess the influence of psychosocial factors and some clinical conditions on the occurrence of phantom phenomena in amputee athletes. Subjects: 21 men (age: 31 years, SD = 7.5 years) after lower or upper extremity amputation, who regularly performed high-intensity sports (Amp Football Team Players) were included to the study. Method and equipment: In the research, the following method and tools were used: Questionnaire [Pirowska] adapted for athletes with disabilities, Numerical Rating Scale (NRS) - for phantom pain assessment, McGill Pain Assessment Questionnaire (short version), Beck's Depression Inventory (BDI), State Trait Anxiety Inventory (STAI): X-1 and X-2, shortened version of The World Health Organization Quality of Life (WHOQOLBREFF). Results: In the study group, the lower leg amputations with traumatic etiology were predominant. Phantom sensations were present in all subjects. Half of the respondents claimed to experience phantom sensations at least once a day, paroxysmally. There was a prevalence of phantom sensations characterized as incomplete, immobile limb. Phantom pain was reported by over 85% of respondents. The nature of phantom pain was frequently described as stabbing, squeezing, shooting, pulsing, tiring. There was a significant correlation between phantom pain intensity and anxiety, quality of life, depressive tendencies, perception of phantom pain as the obstacle in daily functioning and intensity of the limb pain before amputation. Conclusions: The etiology of phantom phenomena is complex. Psychological factors seem to have a significant influence on the intensity of the phantom pain. Particular attention should be paid to patients who complain about persistent limb pain before the amputation. These are patients with an increased risk of the phantom pain of relatively high intensity.

Keywords: amputation, phantom pain, phantom sensations, adaptive sports

Procedia PDF Downloads 129
3709 The Effect of Varying Cone Beam Computed Tomography Image Resolution and Field-of-View Centralization on the Effective Radiation Dose

Authors: Fatima M. Jadu, Asmaa A. Alzahrani, Maha A. Almutairi, Salma O. Al-Amoudi, Mawya A. Khafaji

Abstract:

Introduction: Estimating the potential radiation risk for a widely used imaging technique such as cone beam CT (CBCT) is crucial. The aim of this study was to examine the effect of varying two CBCT technical factors, the voxel size (VOX) and the Field-of-View (FOV) centralization, on the radiation dose. Methodology: The head and neck slices of a RANDO® man phantom (Alderson Research Laboratories) were used with nanoDot™ OSLD dosimeters to measure the absorbed radiation dose at 25 predetermined sites. Imaging was done using the i-CAT® (Imaging Science International, Hatfield, PA, USA) CBCT unit. The VOX was changed for every three cycles of exposures from 0.2mm to 0.3mm and then 0.4mm. Then the FOV was centered on the maxilla and mandible alternatively while holding all other factors constant. Finally, the effective radiation dose was calculated for each view and voxel setting. Results: The effective radiation dose was greatest when the smallest VOX was chosen. When the FOV was centered on the maxilla, the highest radiation doses were recorded in the eyes and parotid glands. While on the mandible, the highest radiation doses were recorded in the sublingual and submandibular glands. Conclusion: Minor variations in the CBCT exposure factors significantly affect the effective radiation dose and thus the radiation risk to the patient. Therefore, extreme care must be taken when choosing these parameters especially for vulnerable patients such as children.

Keywords: CBCT, cone beam CT, effective dose, field of view, mandible, maxilla, resolution, voxel

Procedia PDF Downloads 231
3708 Reproducibility of Dopamine Transporter Density Measured with I-123-N-ω-Fluoropropyl-2β-Carbomethoxy-3β-(4-Iodophenyl)Nortropane SPECT in Phantom Studies and Parkinson’s Disease Patients

Authors: Yasuyuki Takahashi, Genta Hoshi, Kyoko Saito

Abstract:

Objectives: The objective of this study was to evaluate the reproducibility of I-123-N-ω-fluoropropyl-2β-carbomethoxy-3β-(4- iodophenyl) nortropane (I-123 FP-CIT) SPECT by using specific binding ratio (SBR) in phantom studies and Parkinson’s Disease (PD) patients. Methods: We made striatum phantom originally and confirmed reproducibility. The phantom studies changed head position and accumulation of FP-CIT, each. And image processing confirms influence on SBR by 30 cases. 30 PD received a SPECT for 3 hours post injection of I-123 FP-CIT 167MBq. Results: SBR decreased in rotatory direction by the patient position by the phantom studies. And, SBR improved the influence after the attenuation and the scatter correction in the cases (y=0.99x+0.57 r2=0.83). However, Stage II recognized dispersion in SBR by low accumulation. Conclusion: Than the phantom studies that assumed the normal cases, the SPECT image after the attenuation and scatter correction had better reproducibility.

Keywords: 123I-FP-CIT, specific binding ratio, Parkinson’s disease

Procedia PDF Downloads 401
3707 Estimation of Normalized Glandular Doses Using a Three-Layer Mammographic Phantom

Authors: Kuan-Jen Lai, Fang-Yi Lin, Shang-Rong Huang, Yun-Zheng Zeng, Po-Chieh Hsu, Jay Wu

Abstract:

The normalized glandular dose (DgN) estimates the energy deposition of mammography in clinical practice. The Monte Carlo simulations frequently use uniformly mixed phantom for calculating the conversion factor. However, breast tissues are not uniformly distributed, leading to errors of conversion factor estimation. This study constructed a three-layer phantom to estimated more accurate of normalized glandular dose. In this study, MCNP code (Monte Carlo N-Particles code) was used to create the geometric structure. We simulated three types of target/filter combinations (Mo/Mo, Mo/Rh, Rh/Rh), six voltages (25 ~ 35 kVp), six HVL parameters and nine breast phantom thicknesses (2 ~ 10 cm) for the three-layer mammographic phantom. The conversion factor for 25%, 50% and 75% glandularity was calculated. The error of conversion factors compared with the results of the American College of Radiology (ACR) was within 6%. For Rh/Rh, the difference was within 9%. The difference between the 50% average glandularity and the uniform phantom was 7.1% ~ -6.7% for the Mo/Mo combination, voltage of 27 kVp, half value layer of 0.34 mmAl, and breast thickness of 4 cm. According to the simulation results, the regression analysis found that the three-layer mammographic phantom at 0% ~ 100% glandularity can be used to accurately calculate the conversion factors. The difference in glandular tissue distribution leads to errors of conversion factor calculation. The three-layer mammographic phantom can provide accurate estimates of glandular dose in clinical practice.

Keywords: Monte Carlo simulation, mammography, normalized glandular dose, glandularity

Procedia PDF Downloads 158
3706 Effective Dose and Size Specific Dose Estimation with and without Tube Current Modulation for Thoracic Computed Tomography Examinations: A Phantom Study

Authors: S. Gharbi, S. Labidi, M. Mars, M. Chelli, F. Ladeb

Abstract:

The purpose of this study is to reduce radiation dose for chest CT examination by including Tube Current Modulation (TCM) to a standard CT protocol. A scan of an anthropomorphic male Alderson phantom was performed on a 128-slice scanner. The estimation of effective dose (ED) in both scans with and without mAs modulation was done via multiplication of Dose Length Product (DLP) to a conversion factor. Results were compared to those measured with a CT-Expo software. The size specific dose estimation (SSDE) values were obtained by multiplication of the volume CT dose index (CTDIvol) with a conversion size factor related to the phantom’s effective diameter. Objective assessment of image quality was performed with Signal to Noise Ratio (SNR) measurements in phantom. SPSS software was used for data analysis. Results showed including CARE Dose 4D; ED was lowered by 48.35% and 51.51% using DLP and CT-expo, respectively. In addition, ED ranges between 7.01 mSv and 6.6 mSv in case of standard protocol, while it ranges between 3.62 mSv and 3.2 mSv with TCM. Similar results are found for SSDE; dose was higher without TCM of 16.25 mGy and was lower by 48.8% including TCM. The SNR values calculated were significantly different (p=0.03<0.05). The highest one is measured on images acquired with TCM and reconstructed with Filtered back projection (FBP). In conclusion, this study proves the potential of TCM technique in SSDE and ED reduction and in conserving image quality with high diagnostic reference level for thoracic CT examinations.

Keywords: anthropomorphic phantom, computed tomography, CT-expo, radiation dose

Procedia PDF Downloads 190
3705 Development of Ultrasounf Probe Holder for Automatic Scanning Asymmetric Reflector

Authors: Nabilah Ibrahim, Hafiz Mohd Zaini, Wan Fatin Liyana Mutalib

Abstract:

Ultrasound equipment or machine is capable to scan in two dimensional (2D) areas. However there are some limitations occur during scanning an object. The problem will occur when scanning process that involving the asymmetric object. In this project, the ultrasound probe holder for asymmetric reflector scanning in 3D image is proposed to make easier for scanning the phantom or object that has asymmetric shape. Initially, the constructed asymmetric phantom that construct will be used in 2D scanning. Next, the asymmetric phantom will be interfaced by the movement of ultrasound probe holder using the Arduino software. After that, the performance of the ultrasound probe holder will be evaluated by using the various asymmetric reflector or phantom in constructing a 3D image

Keywords: ultrasound 3D images, axial and lateral resolution, asymmetric reflector, Arduino software

Procedia PDF Downloads 529
3704 Preparing a Library of Abnormal Masses for Designing a Long-Lasting Anatomical Breast Phantom for Ultrasonography Training

Authors: Nasibullina A., Leonov D.

Abstract:

The ultrasonography method is actively used for the early diagnosis of various le-sions in the human body, including the mammary gland. The incidence of breast cancer has increased by more than 20%, and mortality by 14% since 2008. The correctness of the diagnosis often directly depends on the qualifications and expe-rience of a diagnostic medical sonographer. That is why special attention should be paid to the practical training of future specialists. Anatomical phantoms are ex-cellent teaching tools because they accurately imitate the characteristics of real hu-man tissues and organs. The purpose of this work is to create a breast phantom for practicing ultrasound diagnostic skills in grayscale and elastography imaging, as well as ultrasound-guided biopsy sampling. We used silicone-like compounds ranging from 3 to 17 on the Shore scale hardness units to simulate soft tissue and lesions. Impurities with experimentally selected concentrations were added to give the phantom the necessary attenuation and reflection parameters. We used 3D modeling programs and 3D printing with PLA plastic to create the casting mold. We developed a breast phantom with inclusions of varying shape, elasticity and echogenicity. After testing the created phantom in B-mode and elastography mode, we performed a survey asking 19 participants how realistic the sonograms of the phantom were. The results showed that the closest to real was the model of the cyst with 9.5 on the 0-10 similarity scale. Thus, the developed breast phantom can be used for ultrasonography, elastography, and ultrasound-guided biopsy training.

Keywords: breast ultrasound, mammary gland, mammography, training phantom, tissue-mimicking materials

Procedia PDF Downloads 51
3703 Calculation of Organ Dose for Adult and Pediatric Patients Undergoing Computed Tomography Examinations: A Software Comparison

Authors: Aya Al Masri, Naima Oubenali, Safoin Aktaou, Thibault Julien, Malorie Martin, Fouad Maaloul

Abstract:

Introduction: The increased number of performed 'Computed Tomography (CT)' examinations raise public concerns regarding associated stochastic risk to patients. In its Publication 102, the ‘International Commission on Radiological Protection (ICRP)’ emphasized the importance of managing patient dose, particularly from repeated or multiple examinations. We developed a Dose Archiving and Communication System that gives multiple dose indexes (organ dose, effective dose, and skin-dose mapping) for patients undergoing radiological imaging exams. The aim of this study is to compare the organ dose values given by our software for patients undergoing CT exams with those of another software named "VirtualDose". Materials and methods: Our software uses Monte Carlo simulations to calculate organ doses for patients undergoing computed tomography examinations. The general calculation principle consists to simulate: (1) the scanner machine with all its technical specifications and associated irradiation cases (kVp, field collimation, mAs, pitch ...) (2) detailed geometric and compositional information of dozens of well identified organs of computational hybrid phantoms that contain the necessary anatomical data. The mass as well as the elemental composition of the tissues and organs that constitute our phantoms correspond to the recommendations of the international organizations (namely the ICRP and the ICRU). Their body dimensions correspond to reference data developed in the United States. Simulated data was verified by clinical measurement. To perform the comparison, 270 adult patients and 150 pediatric patients were used, whose data corresponds to exams carried out in France hospital centers. The comparison dataset of adult patients includes adult males and females for three different scanner machines and three different acquisition protocols (Head, Chest, and Chest-Abdomen-Pelvis). The comparison sample of pediatric patients includes the exams of thirty patients for each of the following age groups: new born, 1-2 years, 3-7 years, 8-12 years, and 13-16 years. The comparison for pediatric patients were performed on the “Head” protocol. The percentage of the dose difference were calculated for organs receiving a significant dose according to the acquisition protocol (80% of the maximal dose). Results: Adult patients: for organs that are completely covered by the scan range, the maximum percentage of dose difference between the two software is 27 %. However, there are three organs situated at the edges of the scan range that show a slightly higher dose difference. Pediatric patients: the percentage of dose difference between the two software does not exceed 30%. These dose differences may be due to the use of two different generations of hybrid phantoms by the two software. Conclusion: This study shows that our software provides a reliable dosimetric information for patients undergoing Computed Tomography exams.

Keywords: adult and pediatric patients, computed tomography, organ dose calculation, software comparison

Procedia PDF Downloads 129
3702 Relative Depth Dose Profile and Peak Scatter Factors Measurement for Co-60 Teletherapy Machine Using Chemical Dosimetry

Authors: O. Moussous, T. Medjadj

Abstract:

The suitability of a Fricke dosimeter for the measurement of a relative depth dose profile and the peak scatter factors was studied. The measurements were carried out in the secondary standard dosimetry laboratory at CRNA Algiers using a collimated 60Co gamma source teletherapy machine. The measurements were performed for different field sizes at the phantom front face, at a fixed source-to-phantom distance of 80 cm. The dose measurements were performed by first placing the dosimeters free-in-air at the distance-source-detector (DSD) of 80.5 cm from the source. Additional measurements were made with the phantom in place. The water phantom type Med-Tec 40x40x40 cm for vertical beam was used in this work as scattering martial. The phantom was placed on the irradiation bench of the cobalt unit at the SSD of 80 cm from the beam focus and the centre of the field coincided with the geometric centre of the dosimeters placed at the depth in water of 5 mm Relative depth dose profile and Peak scatter factors measurements were carried out using our Fricke system. This was intercompared with similar measurements by ionization chamber under identical conditions. There is a good agreement between the relative percentage depth–dose profiles and the PSF values measured by both systems using a water phantom.

Keywords: Fricke dosimeter, depth–dose profiles, peak scatter factors, DSD

Procedia PDF Downloads 226
3701 A Comparison of TLD Measurements to MIRD Estimates of the Dose to the Ovaries and Uterus from Tc-99m in Liver

Authors: Karim Adinehvand, Bakhtiar Azadbakht, Amin Sahebnasagh

Abstract:

Relation to high absorption fraction of Tc SESTAMIBI by internal organs in heart scan, and these organs are near to generation organs (Ovaries and uterus). In this study, Liver is specified as source organ. Method: we have set amount of absorbed fraction radiopharmaceutical in position of Liver in RANDO-phantom in form of elliptical surfaces, then absorbed dose to ovaries and uterus measured by TLD-100 that had set at position of these organs in RANDO-phantom. Calculation had done by MIRD method. Results from direct measurement and MIRD method are too similar. The absorbed dose to uterus and ovaries for Rest are 26.05µGyMBq-1, 17.23µGyMBq-1 and for Stress are 2.04µGyMBq-1, 1.35µGyMBq-1 respectively.

Keywords: absorbed dose, TLD, MIRD, RANDO-phantom, Tc-99m

Procedia PDF Downloads 532
3700 Alpha-Theta a Non-Invasive Treatment for the Self-Exploration of Individuals with Conversion Disorder in Pakistani Society

Authors: Muhammad Tahir Khalily

Abstract:

Aim: The purpose of the present study was to examine the effectiveness of alpha-theta brainwave Neuro feedback treatment for the internal self-exploration of individuals with conversion disorder. Method: A Purposive sample technique was used and data collected from Kalsoom International Hospital Islamabad and Al-Malik Medical Center Rawalpindi. 123 participants were examined, Male child = 5, female child = 6, male adult = 64, female adult = 48. This study retrospectively examined the symptomatic changes in clients with a range of psychiatric disorders particularly 13 (Male = 3, Female = 10) conversion disorder clients who have received Neuro feedback treatment. Results: Our results indicated a significant improvement (P < .001) in the amelioration of our clients’ symptoms which have enabled them to bring their emotional memories into conscious awareness for the peaceful resolution without self-detachment. Conclusion: Majority of the clients improved their psychiatric symptoms including the symptoms of conversion disorder and was discharged from therapy with the accomplishment of therapeutic goals.

Keywords: EEG, neurofeedback, conversion, therapy

Procedia PDF Downloads 286
3699 The Effect of Vitamin "E" on the Peripheral Neurotoxicity of Antimony in Adult Male Albino Rat

Authors: Pymaneh Bairami Rad

Abstract:

The present work was planned with the aim to study the histological changes that might occur in the sciatic nerve of adult male albino rat following antimony trioxide exposure and to throw more light on the protective role of vitamin "E" on the peripheral neurotoxicity induced by this environmental toxin Sixty adult male albino rats, weighing 183 - 235 grams, were utilized in this work. The animals were divided into 3 groups; each of 20 rats: animals of group I served as control, animals of group II received antimony trioxide daily for 12 successive weeks , animals of group III received antimony trioxide and vitamin "E" daily for the same duration. Antimony trioxide was given in a daily dose of 500 mg/ kg body weight which represents 1/40 of the known LD50 and vitamin "E" was administered in a daily dose of 300 mg/kg body weight. Both antimony trioxide and vitamin "E" were given to the animals by gastric intubation. This research revealed many histological changes in the sciatic nerve, following exposure to antimony trioxide, including Wallerian degeneration in most myelinated nerve fibers with pleomorphic destruction, fragmentation, loss of normal lamination and rupture of myelin sheaths. The axoplasms of these nerve fibers were irregular, degenerated and contained myelin fragments with loss of neurofibrils. Obvious increase in endoneurium was also observed. Concomitant administration of vitamin "E" with antimony trioxide resulted in marked improvement in the histological changes observed in the sciatic nerve.

Keywords: neurotoxicity, antimony, vitamin e, anatomy, histology

Procedia PDF Downloads 405
3698 Adult Education for Transformation and Security Challenges in Nigeria

Authors: Asmau Zarma Gogaram

Abstract:

The paper examines adult education and how it can be employed as a strategy for transformation and security challenges in Nigeria. It defines the meaning of adult education and its objectives.The issue of the necessity of employing adult education as a strategy for transformation and security challenges was also examined in the paper.In doing this it discussed the different types of adult education programmes, i.e.continuing education, literacy education, retirement and pre-retirement education and civic education. The paper concluded by stating that if the programmes stated are internalizes and applied they can help to raise awareness. Finally the paper proffered some recommendations one of which was that government should at all levels increase their efforts or promoting acquisition of adult education.

Keywords: adult education, transformation and security challenges, Nigeria, education and human development

Procedia PDF Downloads 479
3697 Assessment of Breast, Lung and Liver Effective Doses in Heart Imaging by CT-Scan 128 Dual Sources with Use of TLD-100 in RANDO Phantom

Authors: Seyedeh Sepideh Amini, Navideh Aghaei Amirkhizi, Seyedeh Paniz Amini, Seyed Soheil Sayyahi, Mohammad Reza Davar Panah

Abstract:

CT-Scan is one of the lateral and sectional imaging methods that produce 3D-images with use of rotational x-ray tube around central axis. This study is about evaluation and calculation of effective doses around heart organs such as breast, lung and liver with CT-Scan 128 dual sources with TLD_100 and RANDO Phantom by spiral, flash and conventional protocols. In results, it is showed that in spiral protocol organs have maximum effective dose and minimum in flash protocol. Thus flash protocol advised for children and risk persons.

Keywords: X-ray computed tomography, dosimetry, TLD-100, RANDO, phantom

Procedia PDF Downloads 444
3696 The Influence of Perceived Quality, Customer Satisfaction and Brand Attitude to Brand Loyalty of Adult Magazine in Indonesia (A Case Study of Maxim Magazine)

Authors: Robert Ab Butarbutar, Sutan Musa Buyana

Abstract:

Purpose: The purpose of this study is to empirically test the correlation between several variables: perceived quality, overall customer satisfaction and brand attitude to brand loyalty on Maxim magazine in Indonesia. Since the room of adult magazine in Indonesia is restricted, the study of this category has became so interesting to reveal how those variables occur. Design/ methodology/ approach: The combination of exploratory, descriptive and causal research design used in this study. Non-probability sampling, specifically purposive sampling used to determine 160 respondents. Path analysis used to examine the contribution of antecedents variables, perceived quality, overall satisfaction and brand attitude in contribution to brand loyalty. Additional respondents serve for in-depth interview to enrich findings from questionnaire that directly distributed. Findings: The research shows that perceived quality positively contribute to overall satisfaction and brand attitude. Overall satisfaction also positively influence brand attitude and brand loyalty. Finally, brand attitude directly impact to brand loyalty. Despite the hypothesis testing, qualitative research also shows specific behavior of Indonesian customer in consuming adult magazine. Research limitation/implication: This research limited to adult male (18 years at minimum) and who live in big city as Jakarta. Broader geographical coverage is advisable for further research. This study also serves a call for additional empirical research into different product category that targeted to adult male, Since the research of this segment is quite scarce. Managerial Implications: Since findings show perceived quality positively impact and strong contribute to overall satisfaction and brand attitude, it implies for adult magazine to be driven by quality of content. The selection of model, information of current lifestyle of urban male became prioritizes in developing perceived quality. Differentiation also emerges as critical issues since consumer difficult to differentiate significantly one magazine to another. The way magazine deliver its content toward distinctive communication is highly recommended. Furthermore, brand loyalty faces big challenge. Interactivity toward events and social media become critically important. Originality/ value: perceived quality plays as prerequisite to develop overall satisfaction and brand attitude. Finding shows customer difficult to differentiate among adult magazines. Therefore, brand loyalty become a big challenge for company.

Keywords: perceived quality, overall satisfaction, brand attitude, adult magazine

Procedia PDF Downloads 379
3695 Evolution of Cord Absorbed Dose during Larynx Cancer Radiotherapy, with 3D Treatment Planning and Tissue Equivalent Phantom

Authors: Mohammad Hassan Heidari, Amir Hossein Goodarzi, Majid Azarniush

Abstract:

Radiation doses to tissues and organs were measured using the anthropomorphic phantom as an equivalent to the human body. When high-energy X-rays are externally applied to treat laryngeal cancer, the absorbed dose at the laryngeal lumen is lower than given dose because of air space which it should pass through before reaching the lesion. Specially in case of high-energy X-rays, the loss of dose is considerable. Three-dimensional absorbed dose distributions have been computed for high-energy photon radiation therapy of laryngeal and hypo pharyngeal cancers, using a coaxial pair of opposing lateral beams in fixed positions. Treatment plans obtained under various conditions of irradiation.

Keywords: 3D treatment planning, anthropomorphic phantom, larynx cancer, radiotherapy

Procedia PDF Downloads 516
3694 Comparison of FNTD and OSLD Detectors' Responses to Light Ion Beams Using Monte Carlo Simulations and Exprimental Data

Authors: M. R. Akbari, H. Yousefnia, A. Ghasemi

Abstract:

Al2O3:C,Mg fluorescent nuclear track detector (FNTD) and Al2O3:C optically stimulated luminescence detector (OSLD) are becoming two of the applied detectors in ion dosimetry. Therefore, the response of these detectors to hadron beams is highly of interest in radiation therapy (RT) using ion beams. In this study, these detectors' responses to proton and Helium-4 ion beams were compared using Monte Carlo simulations. The calculated data for proton beams were compared with Markus ionization chamber (IC) measurement (in water phantom) from M.D. Anderson proton therapy center. Monte Carlo simulations were performed via the FLUKA code (version 2011.2-17). The detectors were modeled in cylindrical shape at various depths of the water phantom without shading each other for obtaining relative depth dose in the phantom. Mono-energetic parallel ion beams in different incident energies (100 MeV/n to 250 MeV/n) were collided perpendicularly on the phantom surface. For proton beams, the results showed that the simulated detectors have over response relative to IC measurements in water phantom. In all cases, there were good agreements between simulated ion ranges in the water with calculated and experimental results reported by the literature. For proton, maximum peak to entrance dose ratio in the simulated water phantom was 4.3 compared with about 3 obtained from IC measurements. For He-4 ion beams, maximum peak to entrance ratio calculated by both detectors was less than 3.6 in all energies. Generally, it can be said that FLUKA is a good tool to calculate Al2O3:C,Mg FNTD and Al2O3:C OSLD detectors responses to therapeutic proton and He-4 ion beams. It can also calculate proton and He-4 ion ranges with a reasonable accuracy.

Keywords: comparison, FNTD and OSLD detectors response, light ion beams, Monte Carlo simulations

Procedia PDF Downloads 309
3693 Combined Use of FMRI and Voxel-Based Morphometry in Assessment of Memory Impairment in Alzheimer's Disease Patients

Authors: A. V. Sokolov, S. V. Vorobyev, A. Yu. Efimtcev, V. Yu. Lobzin, I. A. Lupanov, O. A. Cherdakov, V. A. Fokin

Abstract:

Alzheimer’s disease (AD) is the most common form of dementia. Different brain regions are involved to the pathological process of AD. The purpose of this study was to evaluate brain activation by visual memory task in patients with Alzheimer's disease and determine correlation between memory impairment and atrophy of memory specific brain regions of frontal and medial temporal lobes. To investigate the organization of memory and localize cortical areas activated by visual memory task we used functional magnetic resonance imaging and to evaluate brain atrophy of patients with Alzheimer's disease we used voxel-based morphometry. FMRI was performed on 1.5 T MR-scanner Siemens Magnetom Symphony with BOLD (Blood Oxygenation Level Dependent) technique, based on distinctions of magnetic properties of hemoglobin. For test stimuli we used series of 12 not related images for "Baseline" and 12 images with 6 presented before for "Active". Stimuli were presented 3 times with reduction of repeated images to 4 and 2. Patients with Alzheimer's disease showed less activation in hippocampal formation (HF) region and parahippocampal gyrus then healthy persons of control group (p<0.05). The study also showed reduced activation in posterior cingulate cortex (p<0.001). Voxel-based morphometry showed significant atrophy of grey matter in Alzheimer’s disease patients, especially of both temporal lobes (fusiform and parahippocampal gyri); frontal lobes (posterior cingulate and superior frontal gyri). The study showed correlation between memory impairment and atrophy of memory specific brain regions of frontal and medial temporal lobes. Thus, reduced activation in hippocampal formation and parahippocampal gyri, in posterior cingulate gyrus in patients with Alzheimer's disease correlates to significant atrophy of these regions, detected by voxel-based morphometry, and to deterioration of specific cognitive functions.

Keywords: Alzheimer’s disease, functional MRI, voxel-based morphometry

Procedia PDF Downloads 286
3692 Effect of Omeprazole on the Renal Cortex of Adult Male Albino Rats and the Possible Protective Role of Ginger: Histological and Immunohistochemical study

Authors: Nashwa A. Mohamed

Abstract:

Introduction: Omeprazole is a proton pump inhibitor used commonly in the treatment of acid-peptic disorders. Although omeprazole is generally well tolerated, serious adverse effects such as renal failure have been reported. Ginger is an antioxidant that could play a protective role in models of experimentally induced nephropathies. Aim of the work: The aim of this work was to study the possible histological changes induced by omeprazole on renal cortex and evaluate the possible protective effect of ginger on omeprazole-induced renal damage in adult male albino rats. Materials and methods: Twenty-four adult male albino rats divided into four groups (six rats each) were used in this study. Group I served as the control group. Rats of group II received only an aqueous extract of ginger daily for 3 months through a gastric tube. Rats of group III were received omeprazole orally through a gastric tube for 3 months. Rats of group IV were given both ginger and omeprazole at the same doses and through the same routes as the previous two groups. At the end of the experiment, the rats were sacrificed. Renal tissue samples were processed for light, immunohistochemical and electron microscopic examination. The obtained results were analysed morphometrically and statistically. Results: Omeprazole caused several histological changes in the form of loss of normal appearance of renal cortex with degenerative changes in the renal corpuscle and tubules. Cellular infilteration was also observed. The filteration barrier was markedly affected. Ginger ameliorated the omeprazole-induced histological changes. Conclusion: Omeprazole induced injurious effects on renal cortex. Coadministration of ginger can ameliorate the histological changes induced by omeprazole.

Keywords: ginger, kidney, omeprazole, rat

Procedia PDF Downloads 226
3691 Realistic Modeling of the Preclinical Small Animal Using Commercial Software

Authors: Su Chul Han, Seungwoo Park

Abstract:

As the increasing incidence of cancer, the technology and modality of radiotherapy have advanced and the importance of preclinical model is increasing in the cancer research. Furthermore, the small animal dosimetry is an essential part of the evaluation of the relationship between the absorbed dose in preclinical small animal and biological effect in preclinical study. In this study, we carried out realistic modeling of the preclinical small animal phantom possible to verify irradiated dose using commercial software. The small animal phantom was modeling from 4D Digital Mouse whole body phantom. To manipulate Moby phantom in commercial software (Mimics, Materialise, Leuven, Belgium), we converted Moby phantom to DICOM image file of CT by Matlab and two- dimensional of CT images were converted to the three-dimensional image and it is possible to segment and crop CT image in Sagittal, Coronal and axial view). The CT images of small animals were modeling following process. Based on the profile line value, the thresholding was carried out to make a mask that was connection of all the regions of the equal threshold range. Using thresholding method, we segmented into three part (bone, body (tissue). lung), to separate neighboring pixels between lung and body (tissue), we used region growing function of Mimics software. We acquired 3D object by 3D calculation in the segmented images. The generated 3D object was smoothing by remeshing operation and smoothing operation factor was 0.4, iteration value was 5. The edge mode was selected to perform triangle reduction. The parameters were that tolerance (0.1mm), edge angle (15 degrees) and the number of iteration (5). The image processing 3D object file was converted to an STL file to output with 3D printer. We modified 3D small animal file using 3- Matic research (Materialise, Leuven, Belgium) to make space for radiation dosimetry chips. We acquired 3D object of realistic small animal phantom. The width of small animal phantom was 2.631 cm, thickness was 2.361 cm, and length was 10.817. Mimics software supported efficiency about 3D object generation and usability of conversion to STL file for user. The development of small preclinical animal phantom would increase reliability of verification of absorbed dose in small animal for preclinical study.

Keywords: mimics, preclinical small animal, segmentation, 3D printer

Procedia PDF Downloads 341
3690 Measurement of IMRT Dose Distribution in Rando Head and Neck Phantom using EBT3 Film

Authors: Pegah Safavi, Mehdi Zehtabian, Mohammad Amin Mosleh-Shirazi

Abstract:

Cancer is one of the leading causes of death in the world. Radiation therapy is one of the main choices for cancer treatment. Intensity-modulated radiation therapy is a new type of radiation therapy technique available for vital structures such as the parathyroid glands. It is very important to check the accuracy of the delivered IMRT treatment because any mistake may lead to more complications for the patient. This paper describes an experiment to determine the accuracy of a dose measured by EBT3 film. To test this method, the EBT3 film on the head and neck of the Rando phantom was irradiated by an IMRT device and the irradiation was repeated twice. Finally, the dose designed by the irradiation system was compared with the dose measured by the EBT3 film. Using this criterion, the accuracy of the EBT3 film was evaluated. When using this criterion, a 95% agreement was reached between the planned treatment and the measured values.

Keywords: EBT3, phantom, accuracy, cancer, IMRT

Procedia PDF Downloads 117
3689 Acquisition of Anticipatory Coarticulation in Italian-Speaking Children: An Acoustic Study

Authors: Patrizia Bonaventura

Abstract:

The aim of this study is to analyze the influence of prosody on the acquisition of temporal aspects of V-V anticipatory lingual coarticulation in productions by Italian-speaking children. Two twin 7-years old male children, native Italian speakers, interacted with the same adult, repeating nonsense disyllables containing VtV sequences where V1 = {i, a} and V2 = {a,e, i, o,u}, with different stress patterns (e.g. pi’ta, pi’ta). The duration of the VC F2 transitions and the CV/VC F2 transitions durations ratios in different V2 contexts and stress conditions were measured by spectrographic analysis and compared between pronunciations by each child vs. the adult to test whether the child was able to imitate the duration of the transitions as produced by the adult in different stress conditions. Consequences highlighted a significant difference in durations of VC transitions between children and adult: longer VC transitions durations, indicating a greater amount of coarticulation, were found for one child in every context, and for the other, only in stressed [it] sequences. The data support the hypothesis of the presence of different temporal patterns of anticipatory coarticulation in adults and children, and of a greater amount of coarticulation in children, with different strategies of implementation across different prosodic conditions.

Keywords: speech acquisition, coarticulation, Italian language, prosody

Procedia PDF Downloads 56
3688 A Study on Adult Attachment Styles and Romantic Relationship Quality among Young Adults

Authors: Kaliammah Kumaran, Thilaagheswary Thangadurai

Abstract:

This study examined the relationship between anxious attachment and avoidant attachment among young adult romantic relationship quality. Our survey was administered to 300 young adult participants (126 males and 174 females) aged 18-24 years old (M= 20.85, SD=1.89), accomplished the English version of the Revised Adult Attachment Scale (RAAS) used to measure adult attachment and Revised Dyadic Adjustment Scale (RDAS). All the participants were tertiary level students. Findings of our study indicated that young adults experienced anxious attachment style is negatively correlated with romantic relationship quality as well as young adult from avoidant attachment also negatively correlated with romantic relationship quality among young adults. The results showed that insecure adult attachment styles which are anxious and avoidance adult attachment styles links with reduced quality of romantic relationship.

Keywords: adult attachment style, anxious attachment style, avoidant attachment style, romantic relationship quality

Procedia PDF Downloads 359