Search results for: left ventricle assist device (LVAD)
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4086

Search results for: left ventricle assist device (LVAD)

3846 Enhancement of Learning Style in Kolej Poly-Tech MARA (KPTM) via Mobile EEF Learning System (MEEFLS)

Authors: M. E. Marwan, A. R. Madar, N. Fuad

Abstract:

Mobile communication provides access to the outside world without borders everywhere and at any time. The learning method that related to mobile communication technology is known as mobile learning (M-learning). It is a method that communicates learning materials with mobile device technology. The purpose of this method is to increase the interest in learning among students and assist them in obtaining learning materials at Kolej Poly-Tech MARA (KPTM) in order to improve the student’s performance in their study and to encourage educators to diversify the teaching practices. This paper discusses the student’s awareness for enhancement of learning style using mobile technologies and their readiness to apply the elements of mobile learning in learning to improve performance and interest in learning among students. An application called Mobile EEF Learning System (MEEFLS) has been developed as a tool to be used as a pilot test in KPTM.

Keywords: awareness, mobile learning, MEEFLS, teaching and learning, readiness

Procedia PDF Downloads 363
3845 Impact of Chemical Flooding on Displacement Efficiency in Shallow Carbonate Marine Reservoir (Case Study)

Authors: Tarek Duzan, Walid Eddib

Abstract:

The marine shallow carbonate reservoir (G- Eocene) is one of the biggest mature water drive reservoir of Waha Oil Company. The cumulative oil produced up to date is about to eighty percent of the booked original oil in place at ninety five percent of Water cut. However, the company believes that there is a good amount of remaining oil left need to be recovered. Many laboratory studies have been conducted to see the possibility drain the commercial oil left behind using two types of gases, namely, carbone dioxide and enriched hydrocarbon gas injection. The conclusions of those cases were inconclusive Technically and Economically. Therefore, the company has decided to verify another Tertiary Recovery (EOR) technique that may be applied to the interested reservoir. A global screening criteria and quick Laboratory chemical tests have been conducted by using many types of chemical injection into real rock samples. The outcomes were unique economically and provide a significant increase in the commercial oil left. Finally, the company has started conducting a sector pilot plan before proceeding with a full plan. There are many wellbores available to use in a potential field Enhanced Oil Recovery.

Keywords: chemical lab. test, ASP, rock types, oil samples, and global screening criteria

Procedia PDF Downloads 123
3844 Internet of Things Edge Device Power Modelling and Optimization Simulator

Authors: Cian O'Shea, Ross O'Halloran, Peter Haigh

Abstract:

Wireless Sensor Networks (WSN) are Internet of Things (IoT) edge devices. They are becoming widely adopted in many industries, including health care, building energy management, and conditional monitoring. As the scale of WSN deployments increases, the cost and complexity of battery replacement and disposal become more significant and in time may become a barrier to adoption. Harvesting ambient energies provide a pathway to reducing dependence on batteries and in the future may lead to autonomously powered sensors. This work describes a simulation tool that enables the user to predict the battery life of a wireless sensor that utilizes energy harvesting to supplement the battery power. To create this simulator, all aspects of a typical WSN edge device were modelled including, sensors, transceiver, and microcontroller as well as the energy source components (batteries, solar cells, thermoelectric generators (TEG), supercapacitors and DC/DC converters). The tool allows the user to plug and play different pre characterized devices as well as add user-defined devices. The goal of this simulation tool is to predict the lifetime of a device and scope for extension using ambient energy sources.

Keywords: Wireless Sensor Network, IoT, edge device, simulation, solar cells, TEG, supercapacitor, energy harvesting

Procedia PDF Downloads 112
3843 Flexible Polyaniline-Based Composite Films for High-Performance Super Capacitors

Authors: A. Khosrozadeh, M. A. Darabi, M. Xing, Q. Wang

Abstract:

Fabrication of a high-performance supercapacitor (SC) using a flexible cellulose-based composite film of polyaniline (PANI), reduced graphene oxide (RGO), and silver nanowires (AgNWs) is reported. The flexibility, high capacitive behaviour, and cyclic stability of the entire device make it a good candidate for wearable SCs. The results show that a capacitance as high as 73.4 F/g (1.6 F/cm2) at a discharge rate of 1.1 A/g is achieved by the device. In addition, the SC demonstrates a power density up to 468.8 W/kg and an energy density up to 5.1 wh/kg. The flexibility of the composite film is attributed to the binding effect of cellulose fibers as well as reinforcing effect of AgNWs. The excellent electrochemical performance of the device is found to be owing to the synergistic effect between PANI/RGO/AgNWs ternary in a cushiony cellulose matrix and porous structure of the composite.

Keywords: cellulose, polyaniline, reduced graphene oxide, silver, super capacitor

Procedia PDF Downloads 407
3842 Leaving to Make a Living: Differences on the Subjective Well-Being of Children in Transnational Families and in Families Living Together

Authors: Rachelle Angeli Maranon

Abstract:

This research explored the relationships of a child’s family condition, sex and subjective well-being (SWB) to gain some understanding of the experiences of both transnational and non-transnational families. A descriptive-correlational design was used to study the variables. Participants included 52 male and female children from Iloilo and Kabankalan cities, representing the family conditions in this study. Data were gathered using a semi-structured interview guide. Responses were analyzed using Mann-Whitney U Test. The results showed that the SWB of non-transnational children was significantly higher compared to their transnational counterparts (U = 134, p = .00). Also, analysis between females and males indicated a significant difference only on some aspects (U = 318, p = .71). Some recommendations were suggested to better understand the plight of the left-behind children.

Keywords: left-behind children, mothers, subjective well-being, transnational families

Procedia PDF Downloads 426
3841 Smart Monitoring and Control of Tap Changer Using Intelligent Electronic Device

Authors: K. N. Dinesh Babu, M. V. Gopalan, G. R. Manjunatha, R. Ramaprabha, V. Rajini

Abstract:

In this paper, monitoring and control of tap changer mechanism of a transformer implementation in an intelligent electronic device (IED) is discussed. Its been a custom for decades to provide a separate panel for on load tap changer control for monitoring the tap position. However this facility cannot either record or transfer the information to remote control centers. As there is a technology shift towards the smart grid protection and control standards, the need for implementing remote control and monitoring has necessitated the implementation of this feature in numerical relays. This paper deals with the programming, settings and logic implementation which is applicable to both IEC 61850 compatible and non-compatible IEDs thereby eliminating the need for separate tap changer control equipment. The monitoring mechanism has been implemented in a 28MVA, 110 /6.9kV transformer with 16 tap position with GE make T60 IED at Ultratech cement limited Gulbarga, Karnataka and is in successful service.

Keywords: transformer protection, tap changer control, tap position monitoring, on load tap changer, intelligent electronic device (IED)

Procedia PDF Downloads 577
3840 Analysis of Heat Transfer in a Closed Cavity Ventilated Inside

Authors: Benseghir Omar, Bahmed Mohamed

Abstract:

In this work, we presented a numerical study of the phenomenon of heat transfer through the laminar, incompressible and steady mixed convection in a closed square cavity with the left vertical wall of the cavity is subjected to a warm temperature, while the right wall is considered to be cold. The horizontal walls are assumed adiabatic. The governing equations were discretized by finite volume method on a staggered mesh and the SIMPLER algorithm was used for the treatment of velocity-pressure coupling. The numerical simulations were performed for a wide range of Reynolds numbers 1, 10, 100, and 1000 numbers are equal to 0.01,0.1 Richardson, 0.5,1 and 10.The analysis of the results shows a flow bicellular (two cells), one is created by the speed of the fan placed in the inner cavity, one on the left is due to the difference between the temperatures right wall and the left wall. Knowledge of the intensity of each of these cells allowed us to get an original result. And the values obtained from each of Nuselt convection which allow to know the rate of heat transfer in the cavity.Finally we find that there is a significant influence on the position of the fan on the heat transfer (Nusselt evolution) for values of Reynolds studied and for low values of Richardson handed this influence is negligible for high values of the latter.

Keywords: thermal transfer, mixed convection, square cavity, finite volume method

Procedia PDF Downloads 416
3839 Battery/Supercapacitor Emulator for Chargers Functionality Testing

Authors: S. Farag, A. Kuperman

Abstract:

In this paper, design of solid-state battery/super capacitor emulator based on dc-dc boost converter is described. The emulator mimics charging behavior of any storage device based on a predefined behavior set by the user. The device is operated by a two-level control structure: high-level emulating controller and low-level input voltage controller. Simulation and experimental results are shown to demonstrate the emulator operation.

Keywords: battery, charger, energy, storage, super capacitor

Procedia PDF Downloads 385
3838 Enhancing Health Information Management with Smart Rings

Authors: Bhavishya Ramchandani

Abstract:

A little electronic device that is worn on the finger is called a smart ring. It incorporates mobile technology and has features that make it simple to use the device. These gadgets, which resemble conventional rings and are usually made to fit on the finger, are outfitted with features including access management, gesture control, mobile payment processing, and activity tracking. A poor sleep pattern, an irregular schedule, and bad eating habits are all part of the problems with health that a lot of people today are facing. Diets lacking fruits, vegetables, legumes, nuts, and whole grains are common. Individuals in India also experience metabolic issues. In the medical field, smart rings will help patients with problems relating to stomach illnesses and the incapacity to consume meals that are tailored to their bodies' needs. The smart ring tracks all bodily functions, including blood sugar and glucose levels, and presents the information instantly. Based on this data, the ring generates what the body will find to be perfect insights and a workable site layout. In addition, we conducted focus groups and individual interviews as part of our core approach and discussed the difficulties they're having maintaining the right diet, as well as whether or not the smart ring will be beneficial to them. However, everyone was very enthusiastic about and supportive of the concept of using smart rings in healthcare, and they believed that these rings may assist them in maintaining their health and having a well-balanced diet plan. This response came from the primary data, and also working on the Emerging Technology Canvas Analysis of smart rings in healthcare has led to a significant improvement in our understanding of the technology's application in the medical field. It is believed that there will be a growing demand for smart health care as people become more conscious of their health. The majority of individuals will finally utilize this ring after three to four years when demand for it will have increased. Their daily lives will be significantly impacted by it.

Keywords: smart ring, healthcare, electronic wearable, emerging technology

Procedia PDF Downloads 45
3837 Predictive Value of ¹⁸F-Fdg Accumulation in Visceral Fat Activity to Detect Colorectal Cancer Metastases

Authors: Amil Suleimanov, Aigul Saduakassova, Denis Vinnikov

Abstract:

Objective: To assess functional visceral fat (VAT) activity evaluated by ¹⁸F-fluorodeoxyglucose (¹⁸F-FDG) positron emission tomography/computed tomography (PET/CT) as a predictor of metastases in colorectal cancer (CRC). Materials and methods: We assessed 60 patients with histologically confirmed CRC who underwent 18F-FDG PET/CT after a surgical treatment and courses of chemotherapy. Age, histology, stage, and tumor grade were recorded. Functional VAT activity was measured by maximum standardized uptake value (SUVmax) using ¹⁸F-FDG PET/CT and tested as a predictor of later metastases in eight abdominal locations (RE – Epigastric Region, RLH – Left Hypochondriac Region, RRL – Right Lumbar Region, RU – Umbilical Region, RLL – Left Lumbar Region, RRI – Right Inguinal Region, RP – Hypogastric (Pubic) Region, RLI – Left Inguinal Region) and pelvic cavity (P) in the adjusted regression models. We also report the best areas under the curve (AUC) for SUVmax with the corresponding sensitivity (Se) and specificity (Sp). Results: In both adjusted for age regression models and ROC analysis, 18F-FDG accumulation in RLH (cutoff SUVmax 0.74; Se 75%; Sp 61%; AUC 0.668; p = 0.049), RU (cutoff SUVmax 0.78; Se 69%; Sp 61%; AUC 0.679; p = 0.035), RRL (cutoff SUVmax 1.05; Se 69%; Sp 77%; AUC 0.682; p = 0.032) and RRI (cutoff SUVmax 0.85; Se 63%; Sp 61%; AUC 0.672; p = 0.043) could predict later metastases in CRC patients, as opposed to age, sex, primary tumor location, tumor grade and histology. Conclusions: VAT SUVmax is significantly associated with later metastases in CRC patients and can be used as their predictor.

Keywords: ¹⁸F-FDG, PET/CT, colorectal cancer, predictive value

Procedia PDF Downloads 103
3836 Prediction of Super-Response to Cardiac Resynchronisation Therapy

Authors: Vadim A. Kuznetsov, Anna M. Soldatova, Tatyana N. Enina, Elena A. Gorbatenko, Dmitrii V. Krinochkin

Abstract:

The aim of the study was to evaluate potential parameters related with super-response to CRT. Methods: 60 CRT patients (mean age 54.3 ± 9.8 years; 80% men) with congestive heart failure (CHF) II-IV NYHA functional class, left ventricular ejection fraction < 35% were enrolled. At baseline, 1 month, 3 months and each 6 months after implantation clinical, electrocardiographic and echocardiographic parameters, NT-proBNP level were evaluated. According to the best decrease of left ventricular end-systolic volume (LVESV) (mean follow-up period 33.7 ± 15.1 months) patients were classified as super-responders (SR) (n=28; reduction in LVESV ≥ 30%) and non-SR (n=32; reduction in LVESV < 30%). Results: At baseline groups differed in age (58.1 ± 5.8 years in SR vs 50.8 ± 11.4 years in non-SR; p=0.003), gender (female gender 32.1% vs 9.4% respectively; p=0.028), width of QRS complex (157.6 ± 40.6 ms in SR vs 137.6 ± 33.9 ms in non-SR; p=0.044). Percentage of LBBB was equal between groups (75% in SR vs 59.4% in non-SR; p=0.274). All parameters of mechanical dyssynchrony were higher in SR, but only difference in left ventricular pre-ejection period (LVPEP) was statistically significant (153.0 ± 35.9 ms vs. 129.3 ± 28.7 ms p=0.032). NT-proBNP level was lower in SR (1581 ± 1369 pg/ml vs 3024 ± 2431 pg/ml; p=0.006). The survival rates were 100% in SR and 90.6% in non-SR (log-rank test P=0.002). Multiple logistic regression analysis showed that LVPEP (HR 1.024; 95% CI 1.004–1.044; P = 0.017), baseline NT-proBNP level (HR 0.628; 95% CI 0.414–0.953; P=0.029) and age at baseline (HR 1.094; 95% CI 1.009-1.168; P=0.30) were independent predictors for CRT super-response. ROC curve analysis demonstrated sensitivity 71.9% and specificity 82.1% (AUC=0.827; p < 0.001) of this model in prediction of super-response to CRT. Conclusion: Super-response to CRT is associated with better survival in long-term period. Presence of LBBB was not associated with super-response. LVPEP, NT-proBNP level, and age at baseline can be used as independent predictors of CRT super-response.

Keywords: cardiac resynchronisation therapy, superresponse, congestive heart failure, left bundle branch block

Procedia PDF Downloads 375
3835 Noninvasive Brain-Machine Interface to Control Both Mecha TE Robotic Hands Using Emotiv EEG Neuroheadset

Authors: Adrienne Kline, Jaydip Desai

Abstract:

Electroencephalogram (EEG) is a noninvasive technique that registers signals originating from the firing of neurons in the brain. The Emotiv EEG Neuroheadset is a consumer product comprised of 14 EEG channels and was used to record the reactions of the neurons within the brain to two forms of stimuli in 10 participants. These stimuli consisted of auditory and visual formats that provided directions of ‘right’ or ‘left.’ Participants were instructed to raise their right or left arm in accordance with the instruction given. A scenario in OpenViBE was generated to both stimulate the participants while recording their data. In OpenViBE, the Graz Motor BCI Stimulator algorithm was configured to govern the duration and number of visual stimuli. Utilizing EEGLAB under the cross platform MATLAB®, the electrodes most stimulated during the study were defined. Data outputs from EEGLAB were analyzed using IBM SPSS Statistics® Version 20. This aided in determining the electrodes to use in the development of a brain-machine interface (BMI) using real-time EEG signals from the Emotiv EEG Neuroheadset. Signal processing and feature extraction were accomplished via the Simulink® signal processing toolbox. An Arduino™ Duemilanove microcontroller was used to link the Emotiv EEG Neuroheadset and the right and left Mecha TE™ Hands.

Keywords: brain-machine interface, EEGLAB, emotiv EEG neuroheadset, OpenViBE, simulink

Procedia PDF Downloads 481
3834 Configuration Design and Optimization of the Movable Leg-Foot Lunar Soft-Landing Device

Authors: Shan Jia, Jinbao Chen, Jinhua Zhou, Jiacheng Qian

Abstract:

Lunar exploration is a necessary foundation for deep-space exploration. For the functional limitations of the fixed landers which are widely used currently and are to expand the detection range by the use of wheeled rovers with unavoidable path-repeatability, a movable lunar soft-landing device based on cantilever type buffer mechanism and leg-foot type walking mechanism is presented. Firstly, a 20 DoFs quadruped configuration based on pushrod is proposed. The configuration is of the bionic characteristics such as hip, knee and ankle joints, and can make the kinematics of the whole mechanism unchanged before and after buffering. Secondly, the multi-function main/auxiliary buffers based on crumple-energy absorption and screw-nut mechanism, as well as the telescopic device which could be used to protect the plantar force sensors during the buffer process are designed. Finally, the kinematic model of the whole mechanism is established, and the configuration optimization of the whole mechanism is completed based on the performance requirements of slope adaptation and obstacle crossing. This research can provide a technical solution integrating soft-landing, large-scale inspection and material-transfer for future lunar exploration and even mars exploration, and can also serve as the technical basis for developing the reusable landers.

Keywords: configuration design, lunar soft-landing device, movable, optimization

Procedia PDF Downloads 136
3833 Study on Filter for Semiconductor of Minimizing Damage by X-Ray Laminography

Authors: Chan Jong Park, Hye Min Park, Jeong Ho Kim, Ki Hyun Park, Koan Sik Joo

Abstract:

This research used the MCNPX simulation program to evaluate the utility of a filter that was developed to minimize the damage to a semiconductor device during defect testing with X-ray. The X-ray generator was designed using the MCNPX code, and the X-ray absorption spectrum of the semiconductor device was obtained based on the designed X-ray generator code. To evaluate the utility of the filter, the X-ray absorption rates of the semiconductor device were calculated and compared for Ag, Rh, Mo and V filters with thicknesses of 25μm, 50μm, and 75μm. The results showed that the X-ray absorption rate varied with the type and thickness of the filter, ranging from 8.74% to 49.28%. The Rh filter showed the highest X-ray absorption rates of 29.8%, 15.18% and 8.74% for the above-mentioned filter thicknesses. As shown above, the characteristics of the X-ray absorption with respect to the type and thickness of the filter were identified using MCNPX simulation. With these results, both time and expense could be saved in the production of the desired filter. In the future, this filter will be produced, and its performance will be evaluated.

Keywords: X-ray, MCNPX, filter, semiconductor, damage

Procedia PDF Downloads 402
3832 Shape Optimization of a Hole for Water Jetting in a Spudcan for a Jack-Up Rig

Authors: Han Ik Park, Jeong Hyeon Seong, Dong Seop Han, Su-Chul Shin, Young Chul Park

Abstract:

A Spudcan is mounted on the lower leg of the jack-up rig, a device for preventing a rollover of a structure and to support the structure in a stable sea floor. At the time of inserting the surface of the spud can to penetrate when the sand layer is stable and smoothly pulled to the clay layer, and at that time of recovery when uploading the spud can is equipped with a water injection device. In this study, it is significant to optimize the shape of pipelines holes for water injection device and it was set in two kinds of shape, the oval and round. Interpretation of the subject into the site of Gulf of Mexico offshore Wind Turbine Installation Vessels (WTIV)was chosen as a target platform. Using the ANSYS Workbench commercial programs, optimal design was conducted. The results of this study can be applied to the hole-shaped design of various marine structures.

Keywords: kriging method, jack-up rig, shape optimization, spudcan

Procedia PDF Downloads 490
3831 Synthesis of Pyrimidine-Based Polymers Consist of 2-{3-[4,6-Bis-(4-Hexyl-Thiophen-2-yl)-Pyrimidin-2-yl]Phenyl}-Thiazolo[5,4-B]Pyridine as Electron-Deficient Unit for Photovoltaics

Authors: Hyehyeon Lee, Juwon Yu, Juwon Kim, Raquel Kristina Leoni Tumiar, Taewon Kim, Juae Kim, Hongsuk Suh

Abstract:

Recently, the development of photovoltaics is rapidly accelerating as one of green energy sources. So we designed pyrimidine-based polymers with 2-{3-[4,6-bis-(4-hexyl-thiophen-2-yl)-pyrimidin-2-yl]-phenyl}-thiazolo[5,4-b]pyridine (mPTP), as active layer substances for polymer solar cells. Polymers with push-pull types, mPTPBDT-12, mPTPBDT-EH, mPTPBDTT-EH and mPTPTTI, are comprised of electron pushing unit using benzo[1,2-b;3,4-b’]dithiophene (BDT) or 4,8-bis(5-thiophen-2-yl)benzo[1,2-b:4,5-b']dithiophene (BDTT) or 6-(2-thienyl)-4H-thieno[3,2-b]indole(TTI) and electron pulling unit using mPTP. The device including mPTPTTI-12 indicated a VOC of 0.67 V, a JSC of 2.16 mA/cm², and a fill factor (FF) of 0.30, giving a power conversion efficiency (PCE) of 0.43%. The device including mPTPBDT-EH indicated a VOC of 0.56 V, a JSC of 2.64 mA/cm², and an FF of 0.30, giving a PCE of 0.44%. The device including mPTPBDTT-EH indicated a VOC of 0.44 V, a JSC of 2.45 mA/cm², and an FF of 0.29, giving a PCE of 0.31%. The device including mPTPTTI indicated a VOC of 0.72 V, a JSC of 4.95 mA/cm², and an FF of 0.32, giving a PCE of 1.15%. Therefore, mPTPBDT-12, mPTPBDT-EH, mPTPBDTT-EH and mPTPTTI were fabricated by Stille polymerization. Their optical properties were measured and the results show that pyrimidine-based polymers have a great promise to act as donor of active layer.

Keywords: polymer solar cells, photovoltaics, thiazolopyridine, conjugated polymer

Procedia PDF Downloads 258
3830 EMG Based Orthosis for Upper Limb Rehabilitation in Hemiparesis Patients

Authors: Nancy N. Sharmila, Aparna Mishra

Abstract:

Hemiparesis affects almost 80% of stroke patients each year. It is marked by paralysis or weakness on one half of the body. Our model provides both assistance and physical therapy for hemiparesis patients for swift recovery. In order to accomplish our goal a force is provided that pulls the forearm up (as in flexing the arm), and pushes the forearm down (as in extending the arm), which will also assist the user during ADL (Activities of Daily Living). The model consists of a mechanical component which is placed around the patient’s bicep and an EMG control circuit to assist patients in daily activities, which makes it affordable and easy to use. In order to enhance the neuromuscular system’s effectiveness in synchronize the movement, proprioceptive neuromuscular facilitation (PNF) concept is used. The EMG signals are acquired from the unaffected arm as an input to drive the orthosis. This way the patient is invigorated to use the orthosis for regular exercise.

Keywords: EMG, hemiparesis, orthosis, rehabilitation

Procedia PDF Downloads 427
3829 An Approach to Wind Turbine Modeling for Increasing Its Efficiency

Authors: Rishikesh Dingari, Sai Kiran Dornala

Abstract:

In this paper, a simple method of achieving maximum power by mechanical energy transmission device (METD) with integration to induction generator is proposed. METD functioning is explained and dynamic response of system to step input is plotted. Induction generator is being operated at self-excited mode with excitation capacitor at stator. Voltage and current are observed when linked to METD.

Keywords: mechanical energy transmitting device(METD), self-excited induction generator, wind turbine, hydraulic actuators

Procedia PDF Downloads 331
3828 Optical-Based Lane-Assist System for Rowing Boats

Authors: Stephen Tullis, M. David DiDonato, Hong Sung Park

Abstract:

Rowing boats (shells) are often steered by a small rudder operated by one of the backward-facing rowers; the attention required of that athlete then slightly decreases the power that that athlete can provide. Reducing the steering distraction would then increase the overall boat speed. Races are straight 2000 m courses with each boat in a 13.5 m wide lane marked by small (~15 cm) widely-spaced (~10 m) buoys, and the boat trajectory is affected by both cross-currents and winds. An optical buoy recognition and tracking system has been developed that provides the boat’s location and orientation with respect to the lane edges. This information is provided to the steering athlete as either: a simple overlay on a video display, or fed to a simplified autopilot system giving steering directions to the athlete or directly controlling the rudder. The system is then effectively a “lane-assist” device but with small, widely-spaced lane markers viewed from a very shallow angle due to constraints on camera height. The image is captured with a lightweight 1080p webcam, and most of the image analysis is done in OpenCV. The colour RGB-image is converted to a grayscale using the difference of the red and blue channels, which provides good contrast between the red/yellow buoys and the water, sky, land background and white reflections and noise. Buoy detection is done with thresholding within a tight mask applied to the image. Robust linear regression using Tukey’s biweight estimator of the previously detected buoy locations is used to develop the mask; this avoids the false detection of noise such as waves (reflections) and, in particular, buoys in other lanes. The robust regression also provides the current lane edges in the camera frame that are used to calculate the displacement of the boat from the lane centre (lane location), and its yaw angle. The interception of the detected lane edges provides a lane vanishing point, and yaw angle can be calculated simply based on the displacement of this vanishing point from the camera axis and the image plane distance. Lane location is simply based on the lateral displacement of the vanishing point from any horizontal cut through the lane edges. The boat lane position and yaw are currently fed what is essentially a stripped down marine auto-pilot system. Currently, only the lane location is used in a PID controller of a rudder actuator with integrator anti-windup to deal with saturation of the rudder angle. Low Kp and Kd values decrease unnecessarily fast return to lane centrelines and response to noise, and limiters can be used to avoid lane departure and disqualification. Yaw is not used as a control input, as cross-winds and currents can cause a straight course with considerable yaw or crab angle. Mapping of the controller with rudder angle “overall effectiveness” has not been finalized - very large rudder angles stall and have decreased turning moments, but at less extreme angles the increased rudder drag slows the boat and upsets boat balance. The full system has many features similar to automotive lane-assist systems, but with the added constraints of the lane markers, camera positioning, control response and noise increasing the challenge.

Keywords: auto-pilot, lane-assist, marine, optical, rowing

Procedia PDF Downloads 114
3827 Portable, Noninvasive and Wireless Near Infrared Spectroscopy Device to Monitor Skeletal Muscle Metabolism during Exercise

Authors: Adkham Paiziev, Fikrat Kerimov

Abstract:

Near Infrared Spectroscopy (NIRS) is one of the biophotonic techniques which can be used to monitor oxygenation and hemodynamics in a variety of human tissues, including skeletal muscle. In the present work, we are offering tissue oximetry (OxyPrem) to measure hemodynamic parameters of skeletal muscles in rest and exercise. Purpose: - To elaborate the new wireless, portable, noninvasive, wearable NIRS device to measure skeletal muscle oxygenation during exercise. - To test this device on brachioradialis muscle of wrestler volunteers by using combined method of arterial occlusion (AO) and NIRS (AO+NIRS). Methods: Oxyprem NIRS device has been used together with AO test. AO test and Isometric brachioradialis muscle contraction experiments have been performed on one group of wrestler volunteers. ‘Accu- Measure’ caliper (USA) to measure skinfold thickness (SFT) has been used. Results: Elaborated device consists on power supply box, a sensor head and installed ‘Tubis’ software for data acquisition and to compute deoxyhemoglobin ([HHb), oxyhemoglobin ([O2Hb]), tissue oxygenation (StO2) and muscle tissue oxygen consumption (mVO2). Sensor head consists on four light sources with three light emitting diodes with nominal wavelengths of 760 nm, 805 nm, and 870 nm, and two detectors. AO and isometric voluntary forearm muscle contraction (IVFMC) on five healthy male subjects (23,2±0.84 in age, 0.43±0.05cm of SFT ) and four female subjects (22.0±1.0 in age and 0.24±0.04 cm SFT) has been measured. mVO2 for control group has been calculated (-0.65%/sec±0.07) for male and -0.69%/±0.19 for female subjects). Tissue oxygenation index for wrestlers in average about 75% whereas for control group StO2 =63%. Second experiment was connected with quality monitoring muscle activity during IVFMC at 10%,30% and 50% of MVC. It has been shown, that the concentration changes of HbO2 and HHb positively correlated to the contraction intensity. Conclusion: We have presented a portable multi-channel wireless NIRS device for real-time monitoring of muscle activity. The miniaturized NIRS sensor and the usage of wireless communication make the whole device have a compact-size, thus can be used in muscle monitoring.

Keywords: skeletal muscle, oxygenation, instrumentation, near infrared spectroscopy

Procedia PDF Downloads 258
3826 A Survey and Theory of the Effects of Various Hamlet Videos on Viewers’ Brains

Authors: Mark Pizzato

Abstract:

How do ideas, images, and emotions in stage-plays and videos affect us? Do they evoke a greater awareness (or cognitive reappraisal of emotions) through possible shifts between left-cortical, right-cortical, and subcortical networks? To address these questions, this presentation summarizes the research of various neuroscientists, especially Bernard Baars and others involved in Global Workspace Theory, Matthew Lieberman in social neuroscience, Iain McGilchrist on left and right cortical functions, and Jaak Panksepp on the subcortical circuits of primal emotions. Through such research, this presentation offers an ‘inner theatre’ model of the brain, regarding major hubs of neural networks and our animal ancestry. It also considers recent experiments, by Mario Beauregard, on the cognitive reappraisal of sad, erotic, and aversive film clips. Finally, it applies the inner-theatre model and related research to survey results of theatre students who read and then watched the ‘To be or not to be’ speech in 8 different video versions (from stage and screen productions) of William Shakespeare’s Hamlet. Findings show that students become aware of left-cortical, right-cortical, and subcortical brain functions—and shifts between them—through staging and movie-making choices in each of the different videos.

Keywords: cognitive reappraisal, Hamlet, neuroscience, Shakespeare, theatre

Procedia PDF Downloads 291
3825 Study of Dermatoglyphics Pattern in Patient with Hypertension

Authors: Ajeevan Gautam, Gulam Anwer Khan, Pratibha Pokhrel

Abstract:

Introduction: Dermatoglyphics is the science which deals with the study of dermal ridge configuration on the digits, palms and soles. It is grooved by ridges and forms variety of configurations. The aim of the study was to identify dermal ridge patterns on fingertip of hypertensive patients and in normal population and to compare patterns among them. Methods: The subjects of the study were 130 hypertensives and 130 non-hypertensives cases of Kathmandu Valley aged between 40 to 80 years. Case history was recorded after consent finger prints were taken. Different parameters as whorl, loop, arch and composite patterns were studied and analysed. Result: It revealed, increased whorl pattern in hypertensive. It showed 65.69% whorl, 29.23% loop and 5.07% arch patterns in right hand of hypertensive people. In control, it was found to be 34.46% whorl, 58.15% loop and 5.38% arch patterns respectively. Similarly in left hand 63.69% whorl, 32% loop and 4.30% arch in hypertensive group. In control group it was 60.15% as loop, 35.69% as whorl and 15% as arch. Discussion: Based on findings of the result, it was concluded that the whorl, loop and arch patterns observed as 65.69%, 29.23% and 5.07% respectively in hypertensive cases in right hand. Similarly in left hand, it was found to be 4.30% as arch, 32% as loop and 63.69% as whorl patterns, but in normotensive subjects these patterns were recorded as 36.43%, 58.15%, 5.38% in right hand and 35.69%, 60.15%, 4.15% in left hand as whorl, loop and arch respectively.

Keywords: arch, dermatoglyphics, hypertension, loop, whorl

Procedia PDF Downloads 276
3824 All-Silicon Raman Laser with Quasi-Phase-Matched Structures and Resonators

Authors: Isao Tomita

Abstract:

The principle of all-silicon Raman lasers for an output wavelength of 1.3 μm is presented, which employs quasi-phase-matched structures and resonators to enhance the output power. 1.3-μm laser beams for GE-PONs in FTTH systems generated from a silicon device are very important because such a silicon device can be monolithically integrated with the silicon planar lightwave circuits (Si PLCs) used in the GE-PONs. This reduces the device fabrication processes and time and also optical losses at the junctions between optical waveguides of the Si PLCs and Si laser devices when compared with 1.3-μm III-V semiconductor lasers set on the Si PLCs employed at present. We show that the quasi-phase-matched Si Raman laser with resonators can produce about 174 times larger laser power at 1.3 μm (at maximum) than that without resonators for a Si waveguide of Raman gain 20 cm/GW and optical loss 1.2 dB/cm, pumped at power 10 mW, where the length of the waveguide is 3 mm and its cross-section is (1.5 μm)2.

Keywords: All-Silicon Raman Laser, FTTH, GE-PON, Quasi-Phase-Matched Structure, resonator

Procedia PDF Downloads 238
3823 Predictive Value of ¹⁸F-Fluorodeoxyglucose Accumulation in Visceral Fat Activity to Detect Epithelial Ovarian Cancer Metastases

Authors: A. F. Suleimanov, A. B. Saduakassova, V. S. Pokrovsky, D. V. Vinnikov

Abstract:

Relevance: Epithelial ovarian cancer (EOC) is the most lethal gynecological malignancy, with relapse occurring in about 70% of advanced cases with poor prognoses. The aim of the study was to evaluate functional visceral fat activity (VAT) evaluated by ¹⁸F-fluorodeoxyglucose (¹⁸F-FDG) positron emission tomography/computed tomography (PET/CT) as a predictor of metastases in epithelial ovarian cancer (EOC). Materials and methods: We assessed 53 patients with histologically confirmed EOC who underwent ¹⁸F-FDG PET/CT after a surgical treatment and courses of chemotherapy. Age, histology, stage, and tumor grade were recorded. Functional VAT activity was measured by maximum standardized uptake value (SUVₘₐₓ) using ¹⁸F-FDG PET/CT and tested as a predictor of later metastases in eight abdominal locations (RE – Epigastric Region, RLH – Left Hypochondriac Region, RRL – Right Lumbar Region, RU – Umbilical Region, RLL – Left Lumbar Region, RRI – Right Inguinal Region, RP – Hypogastric (Pubic) Region, RLI – Left Inguinal Region) and pelvic cavity (P) in the adjusted regression models. We also identified the best areas under the curve (AUC) for SUVₘₐₓ with the corresponding sensitivity (Se) and specificity (Sp). Results: In both adjusted-for regression models and ROC analysis, ¹⁸F-FDG accumulation in RE (cut-off SUVₘₐₓ 1.18; Se 64%; Sp 64%; AUC 0.669; p = 0.035) could predict later metastases in EOC patients, as opposed to age, sex, primary tumor location, tumor grade, and histology. Conclusions: VAT SUVₘₐₓ is significantly associated with later metastases in EOC patients and can be used as their predictor.

Keywords: ¹⁸F-FDG, PET/CT, EOC, predictive value

Procedia PDF Downloads 53
3822 Green It-Outsourcing Assurance Model for It-Outsourcing Vendors

Authors: Siffat Ullah Khan, Rahmat Ullah Khan, Rafiq Ahmad Khan, Habibullah Khan

Abstract:

Green IT or green computing has emerged as a fast growing business paradigm in recent years in order to develop energy-efficient Software and peripheral devices. With the constant evolution of technology and the world critical environmental status, all private and public information technology (IT) businesses are moving towards sustainability. We identified, through systematic literature review and questionnaire survey, 9 motivators, in total, faced by vendors in IT-Outsourcing relationship. Amongst these motivators 7 were ranked as critical motivators. We also identified 21, in total, practices for addressing these critical motivators. Based on these inputs we have developed Green IT-Outsourcing Assurance Model (GITAM) for IT-Outsourcing vendors. The model comprises four different levels. i.e. Initial, White, Green and Grey. Each level comprises different critical motivators and their relevant practices. We conclude that our model, GITAM, will assist IT-Outsourcing vendors in gauging their level in order to manage IT-Outsourcing activities in a green and sustainable fashion to assist the environment and to reduce the carbon emission. The model will assist vendors in improving their current level by suggesting various practices. The model will contribute to the body of knowledge in the field of Green IT.

Keywords: Green IT-outsourcing Assurance Model (GITAM), Systematic Literature Review, Empirical Study, Case Study

Procedia PDF Downloads 232
3821 A Folk Theorem with Public Randomization Device in Repeated Prisoner’s Dilemma under Costly Observation

Authors: Yoshifumi Hino

Abstract:

An infinitely repeated prisoner’s dilemma is a typical model that represents teamwork situation. If both players choose costly actions and contribute to the team, then both players are better off. However, each player has an incentive to choose a selfish action. We analyze the game under costly observation. Each player can observe the action of the opponent only when he pays an observation cost in that period. In reality, teamwork situations are often costly observation. Members of some teams sometimes work in distinct rooms, areas, or countries. In those cases, they have to spend their time and money to see other team members if they want to observe it. The costly observation assumption makes the cooperation difficult substantially because the equilibrium must satisfy the incentives not only on the action but also on the observational decision. Especially, it is the most difficult to cooperate each other when the stage-game is prisoner's dilemma because players have to communicate through only two actions. We examine whether or not players can cooperate each other in prisoner’s dilemma under costly observation. Specifically, we check whether symmetric Pareto efficient payoff vectors in repeated prisoner’s dilemma can be approximated by sequential equilibria or not (efficiency result). We show the efficiency result without any randomization device under certain circumstances. It means that players can cooperate with each other without any randomization device even if the observation is costly. Next, we assume that public randomization device is available, and then we show that any feasible and individual rational payoffs in prisoner’s dilemma can be approximated by sequential equilibria under a specific situation (folk theorem). It implies that players can achieve asymmetric teamwork like leadership situation when public randomization device is available.

Keywords: cost observation, efficiency, folk theorem, prisoner's dilemma, private monitoring, repeated games.

Procedia PDF Downloads 220
3820 Device for Thermo-Magnetic Depolymerisation of Plant Biomass Prior to Methane Fermentation

Authors: Mirosław Krzemieniewski, Marcin Zieliński, Marcin Dębowski

Abstract:

This publication presents a device for depolymerisation of plant substrates applicable to agricultural biogas plants and closed-chamber sewage treatment plants where sludge fermentation is bolstered with plant mass. The device consists of a tank with a cover equipped with a heating system, an inlet for the substrate, and an outlet for the depolymerised substrate. Within the tank, a magnet shaft encased in a spiral casing is attached, equipped on its upper end with an internal magnetic disc. A motoreducer is mounted on an external magnetic disc located on the centre of the cover. Depolymerisation of the plant substrate allows for substrate destruction at much lower power levels than by conventional means. The temperature within the reactor can be lowered by 40% in comparison to existing designs. During the depolymerisation process, free radicals are generated within the magnetic field, oxidizing the conditioned substrate and promoting biodegradation. Thus, the fermentation time in the fermenters is reduced by approximately 20%.

Keywords: depolymerisation, pre-treatment, biomass, fermentation

Procedia PDF Downloads 501
3819 Bilateral Hemodynamic Responses on Prefrontal Cortex during Voluntary Regulated Breathing (Pranayama) Practices: A Near Infrared Spectroscopy Study

Authors: Singh Deepeshwar, Suhas Vinchurkar

Abstract:

Similar to neuroimaging findings through functional magnetic resonance imaging (fMRI) assessing regional cerebral blood oxygenation, the functional near infrared spectroscopy (fNIRS) has also been used to assess hemodynamic responses in the imaged region of the brain. The present study assessed hemodynamic responses in terms of changes in oxygenation (HbO), deoxygenation (HbR) and total hemoglobin (THb) on the prefrontal cortex (PFC), bilaterally, using fNIRS in 10 participants who performed three voluntary regulated breathing (pranayama) practices viz. (i) Left nostril breathing (LNB), (ii) Right nostril breathing (RNB); and (iii) Alternating nostril breathing (ANB) and compared with normal breathing as baseline (BS). For this, we used 64 channel NIRS system covering left and the right prefrontal cortex. The normal breathing kept as baseline (BS) measures as regressors in the investigation of hemodynamic responses when compared with LNB, RNB and ANB. In the results, we found greater oxygenation in contralateral side i.e., higher activation on the left prefrontal cortex (lPFC) during RNB, and right prefrontal cortex (rPFC) during LNB, whereas ANB showed greater deoxygenation responses on both sides of PFC. Interestingly, LNB showed increased oxygenation on ipsilateral side i.e., lPFC but not during RNB. This suggests that voluntary regulated breathing produced an immediate effect not only on contralateral but ipsilateral sides of the brain as well. In conclusion, breathing practices are tightly coupled to cerebral rhythms of alternating cerebral hemispheric activity during particular nostril breathing. These results of the specific nostril breathing do not support previous findings of contralateral hemispheric improvement while left or right nostril breathing only.

Keywords: hemodynamic responses, brain, pranayama, voluntary regulated breathing practices, prefrontal cortex

Procedia PDF Downloads 213
3818 Metal Layer Based Vertical Hall Device in a Complementary Metal Oxide Semiconductor Process

Authors: Se-Mi Lim, Won-Jae Jung, Jin-Sup Kim, Jun-Seok Park, Hyung-Il Chae

Abstract:

This paper presents a current-mode vertical hall device (VHD) structure using metal layers in a CMOS process. The proposed metal layer based vertical hall device (MLVHD) utilizes vertical connection among metal layers (from M1 to the top metal) to facilitate hall effect. The vertical metal structure unit flows a bias current Ibias from top to bottom, and an external magnetic field changes the current distribution by Lorentz force. The asymmetric current distribution can be detected by two differential-mode current outputs on each side at the bottom (M1), and each output sinks Ibias/2 ± Ihall. A single vertical metal structure generates only a small amount of hall effect of Ihall due to the short length from M1 to the top metal as well as the low conductivity of the metal, and a series connection between thousands of vertical structure units can solve the problem by providing NxIhall. The series connection between two units is another vertical metal structure flowing current in the opposite direction, and generates negative hall effect. To mitigate the negative hall effect from the series connection, the differential current outputs at the bottom (M1) from one unit merges on the top metal level of the other unit. The proposed MLVHD is simulated in a 3-dimensional model simulator in COMSOL Multiphysics, with 0.35 μm CMOS process parameters. The simulated MLVHD unit size is (W) 10 μm × (L) 6 μm × (D) 10 μm. In this paper, we use an MLVHD with 10 units; the overall hall device size is (W) 10 μm × (L)78 μm × (D) 10 μm. The COMSOL simulation result is as following: the maximum hall current is approximately 2 μA with a 12 μA bias current and 100mT magnetic field; This work was supported by Institute for Information & communications Technology Promotion(IITP) grant funded by the Korea government(MSIP) (No.R7117-16-0165, Development of Hall Effect Semiconductor for Smart Car and Device).

Keywords: CMOS, vertical hall device, current mode, COMSOL

Procedia PDF Downloads 283
3817 A Cellular-Based Structural Health Monitoring Device (HMD) Based on Cost-Effective 1-Axis Accelerometers

Authors: Chih-Hsing Lin, Wen-Ching Chen, Chih-Ting Kuo, Gang-Neng Sung, Chih-Chyau Yang, Chien-Ming Wu, Chun-Ming Huang

Abstract:

This paper proposes a cellular-based structure health monitoring device (HMD) for temporary bridge monitoring without the requirement of power line and internet service. The proposed HMD includes sensor node, power module, cellular gateway, and rechargeable batteries. The purpose of HMD focuses on short-term collection of civil infrastructure information. It achieves the features of low cost by using three 1-axis accelerometers with data synchronization problem being solved. Furthermore, instead of using data acquisition system (DAQ) sensed data is transmitted to Host through cellular gateway. Compared with 3-axis accelerometer, our proposed 1-axis accelerometers based device achieves 50.5% cost saving with high sensitivity 2000mv/g. In addition to fit different monitoring environments, the proposed system can be easily replaced and/or extended with different PCB boards, such as communication interfaces and sensors, to adapt to various applications. Therefore, with using the proposed device, the real-time diagnosis system for civil infrastructure damage monitoring can be conducted effectively.

Keywords: cellular-based structural health monitoring, cost-effective 1-axis accelerometers, short-term monitoring, structural engineering

Procedia PDF Downloads 503