Search results for: left ventricle assist device (LVAD)
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4104

Search results for: left ventricle assist device (LVAD)

3954 A Physiological Approach for Early Detection of Hemorrhage

Authors: Rabie Fadil, Parshuram Aarotale, Shubha Majumder, Bijay Guargain

Abstract:

Hemorrhage is the loss of blood from the circulatory system and leading cause of battlefield and postpartum related deaths. Early detection of hemorrhage remains the most effective strategy to reduce mortality rate caused by traumatic injuries. In this study, we investigated the physiological changes via non-invasive cardiac signals at rest and under different hemorrhage conditions simulated through graded lower-body negative pressure (LBNP). Simultaneous electrocardiogram (ECG), photoplethysmogram (PPG), blood pressure (BP), impedance cardiogram (ICG), and phonocardiogram (PCG) were acquired from 10 participants (age:28 ± 6 year, weight:73 ± 11 kg, height:172 ± 8 cm). The LBNP protocol consisted of applying -20, -30, -40, -50, and -60 mmHg pressure to the lower half of the body. Beat-to-beat heart rate (HR), systolic blood pressure (SBP), diastolic blood pressure (DBP), and mean aerial pressure (MAP) were extracted from ECG and blood pressure. Systolic amplitude (SA), systolic time (ST), diastolic time (DT), and left ventricle Ejection time (LVET) were extracted from PPG during each stage. Preliminary results showed that the application of -40 mmHg i.e. moderate stage simulated hemorrhage resulted significant changes in HR (85±4 bpm vs 68 ± 5bpm, p < 0.01), ST (191 ± 10 ms vs 253 ± 31 ms, p < 0.05), LVET (350 ± 14 ms vs 479 ± 47 ms, p < 0.05) and DT (551 ± 22 ms vs 683 ± 59 ms, p < 0.05) compared to rest, while no change was observed in SA (p > 0.05) as a consequence of LBNP application. These findings demonstrated the potential of cardiac signals in detecting moderate hemorrhage. In future, we will analyze all the LBNP stages and investigate the feasibility of other physiological signals to develop a predictive machine learning model for early detection of hemorrhage.

Keywords: blood pressure, hemorrhage, lower-body negative pressure, LBNP, machine learning

Procedia PDF Downloads 155
3953 Introduction of an Approach of Complex Virtual Devices to Achieve Device Interoperability in Smart Building Systems

Authors: Thomas Meier

Abstract:

One of the major challenges for sustainable smart building systems is to support device interoperability, i.e. connecting sensor or actuator devices from different vendors, and present their functionality to the external applications. Furthermore, smart building systems are supposed to connect with devices that are not available yet, i.e. devices that become available on the market sometime later. It is of vital importance that a sustainable smart building platform provides an appropriate external interface that can be leveraged by external applications and smart services. An external platform interface must be stable and independent of specific devices and should support flexible and scalable usage scenarios. A typical approach applied in smart home systems is based on a generic device interface used within the smart building platform. Device functions, even of rather complex devices, are mapped to that generic base type interface by means of specific device drivers. Our new approach, presented in this work, extends that approach by using the smart building system’s rule engine to create complex virtual devices that can represent the most diverse properties of real devices. We examined and evaluated both approaches by means of a practical case study using a smart building system that we have developed. We show that the solution we present allows the highest degree of flexibility without affecting external application interface stability and scalability. In contrast to other systems our approach supports complex virtual device configuration on application layer (e.g. by administration users) instead of device configuration at platform layer (e.g. platform operators). Based on our work, we can show that our approach supports almost arbitrarily flexible use case scenarios without affecting the external application interface stability. However, the cost of this approach is additional appropriate configuration overhead and additional resource consumption at the IoT platform level that must be considered by platform operators. We conclude that the concept of complex virtual devices presented in this work can be applied to improve the usability and device interoperability of sustainable intelligent building systems significantly.

Keywords: Internet of Things, smart building, device interoperability, device integration, smart home

Procedia PDF Downloads 254
3952 A Study on the Establishment of Performance Evaluation Criteria for MR-Based Simulation Device to Train K-9 Self-Propelled Artillery Operators

Authors: Yonggyu Lee, Byungkyu Jung, Bom Yoon, Jongil Yoon

Abstract:

MR-based simulation devices have been recently used in various fields such as entertainment, medicine, manufacturing, and education. Different simulation devices are also being developed for military equipment training. This is to address the concerns regarding safety accidents as well as cost issues associated with training with expensive equipment. An important aspect of developing simulation devices to replicate military training is that trainees experience the same effect as training with real devices. In this study, the criteria for performance evaluation are established to compare the training effect of an MR-based simulation device to that of an actual device. K-9 Self-propelled artillery (SPA) operators are selected as training subjects. First, MR-based software is developed to simulate the training ground and training scenarios currently used for training SPA operators in South Korea. Hardware that replicates the interior of SPA is designed, and a simulation device that is linked to the software is developed. Second, criteria are established to evaluate the simulation device based on real-life training scenarios. A total of nine performance evaluation criteria were selected based on the actual SPA operation training scenarios. Evaluation items were selected to evaluate whether the simulation device was designed such that trainees would experience the same effect as training in the field with a real SPA. To eval-uate the level of replication by the simulation device of the actual training environments (driving and passing through trenches, pools, protrusions, vertical obstacles, and slopes) and driving conditions (rapid steering, rapid accelerating, and rapid braking) as per the training scenarios, tests were performed under the actual training conditions and in the simulation device, followed by the comparison of the results. In addition, the level of noise felt by operators during training was also selected as an evaluation criterion. Due to the nature of the simulation device, there may be data latency between HW and SW. If the la-tency in data transmission is significant, the VR image information delivered to trainees as they maneuver HW might not be consistent. This latency in data transmission was also selected as an evaluation criterion to improve the effectiveness of the training. Through this study, the key evaluation metrics were selected to achieve the same training effect as training with real equipment in a training ground during the develop-ment of the simulation device for military equipment training.

Keywords: K-9 self-propelled artillery, mixed reality, simulation device, synchronization

Procedia PDF Downloads 51
3951 Rathke’s Cleft Cyst Presenting as Unilateral Visual Field Defect

Authors: Ritesh Verma, Manisha Rathi, Chand Singh Dhull, Sumit Sachdeva, Jitender Phogat

Abstract:

A Rathke's cleft cyst is a benign growth found on the pituitary gland in the brain, specifically a fluid-filled cyst in the posterior portion of the anterior pituitary gland. It occurs when the Rathke's pouch does not develop properly and ranges in size from 2 to 40mm in diameter. A 38-year-old male presented to the outpatient department with loss of vision in the inferior quadrant of the left eye since 15 days. Visual acuity was 6/6 in the right eye and 6/9 in the left eye. Visual field analysis by HFA-24-2 revealed an inferior field defect extending to the supero-temporal quadrant in the left eye. MRI brain and orbit was advised to the patient and it revealed a well defined cystic pituitary adenoma indenting left optic nerve near optic chiasm consistent with the diagnosis of Rathke’s cleft cyst (RCC). The patient was referred to neurosurgery department for further management. Symptoms vary greatly between individuals having RCCs. RCCs can be non-functioning, functioning, or both. Besides headaches, neurocognitive deficits are almost always present but have a high rate of immediate reversal if the cyst is properly treated or drained.

Keywords: pituitary tumors, rathke’s cleft cyst, visual field defects, vision loss

Procedia PDF Downloads 189
3950 Patent on Brian: Brain Waves Stimulation

Authors: Jalil Qoulizadeh, Hasan Sadeghi

Abstract:

Brain waves are electrical wave patterns that are produced in the human brain. Knowing these waves and activating them can have a positive effect on brain function and ultimately create an ideal life. The brain has the ability to produce waves from 0.1 to above 65 Hz. (The Beta One device produces exactly these waves) This is because it is said that the waves produced by the Beta One device exactly match the waves produced by the brain. The function and method of this device is based on the magnetic stimulation of the brain. The technology used in the design and producƟon of this device works in a way to strengthen and improve the frequencies of brain waves with a pre-defined algorithm according to the type of requested function, so that the person can access the expected functions in life activities. to perform better. The effect of this field on neurons and their stimulation: In order to evaluate the effect of this field created by the device, on the neurons, the main tests are by conducting electroencephalography before and after stimulation and comparing these two baselines by qEEG or quantitative electroencephalography method using paired t-test in 39 subjects. It confirms the significant effect of this field on the change of electrical activity recorded after 30 minutes of stimulation in all subjects. The Beta One device is able to induce the appropriate pattern of the expected functions in a soft and effective way to the brain in a healthy and effective way (exactly in accordance with the harmony of brain waves), the process of brain activities first to a normal state and then to a powerful one. Production of inexpensive neuroscience equipment (compared to existing rTMS equipment) Magnetic brain stimulation for clinics - homes - factories and companies - professional sports clubs.

Keywords: stimulation, brain, waves, betaOne

Procedia PDF Downloads 67
3949 The Uruguayan Left Wing from the XX to XXI Century: International Dimensions

Authors: Anton Andreev

Abstract:

With the collapse of the Soviet Union and the collapse of a large part of the socialist regimes, left-wing parties all over the world entered the space of crisis, of problems with ideology, identity, with the definition of its goals and objectives. First of all, we can say that the communist parties actually lost their foundation. In 1992, despite the victory of left-wing forces, a Broad Front in which was the winner in the struggle against dictatorship plunged into a deep crisis, the nature of which is looking for a new platform, a new foundation, new goals. Thus, in the late 20th century, the party has revised theoretical beliefs and positions. Radical communist ideology was moderated to social reformism. Modern leftist movement in Uruguay is a movement of moderate reform. Left forces suggest going through successive changes. Changes in ideology and ideas have influenced to the understanding of foreign policy. After the collapse of the Soviet Union Broad Front has changed the direction of its diplomacy from the orientation to the Soviet state to support the USA policy. Government formed by Broad Front, supported the integration processes in the South America. Uruguay was developing the cooperation in the framework of MERCOSUR and began to create relationship with the new centers of power in world political space. Uruguay in the early 21st century is a country that starts to play important role in the international arena. Elections of 26 October 2014 should answer the question of support of internal policy of a Broad Front, as well as of the support of the diplomatic work of the "Left" governments of the country.

Keywords: Uruguay, broad front, Vazquez, international dimensions

Procedia PDF Downloads 341
3948 Design and Development of Optical Sensor Based Ground Reaction Force Measurement Platform for GAIT and Geriatric Studies

Authors: K. Chethana, A. S. Guru Prasad, S. N. Omkar, B. Vadiraj, S. Asokan

Abstract:

This paper describes an ab-initio design, development and calibration results of an Optical Sensor Ground Reaction Force Measurement Platform (OSGRFP) for gait and geriatric studies. The developed system employs an array of FBG sensors to measure the respective ground reaction forces from all three axes (X, Y and Z), which are perpendicular to each other. The novelty of this work is two folded. One is in its uniqueness to resolve the tri axial resultant forces during the stance in to the respective pure axis loads and the other is the applicability of inherently advantageous FBG sensors which are most suitable for biomechanical instrumentation. To validate the response of the FBG sensors installed in OSGRFP and to measure the cross sensitivity of the force applied in other directions, load sensors with indicators are used. Further in this work, relevant mathematical formulations are presented for extracting respective ground reaction forces from wavelength shifts/strain of FBG sensors on the OSGRFP. The result of this device has implications in understanding the foot function, identifying issues in gait cycle and measuring discrepancies between left and right foot. The device also provides a method to quantify and compare relative postural stability of different subjects under test, which has implications in post surgical rehabilitation, geriatrics and optimizing training protocols for sports personnel.

Keywords: balance and stability, gait analysis, FBG applications, optical sensor ground reaction force platform

Procedia PDF Downloads 394
3947 Development of an EEG-Based Real-Time Emotion Recognition System on Edge AI

Authors: James Rigor Camacho, Wansu Lim

Abstract:

Over the last few years, the development of new wearable and processing technologies has accelerated in order to harness physiological data such as electroencephalograms (EEGs) for EEG-based applications. EEG has been demonstrated to be a source of emotion recognition signals with the highest classification accuracy among physiological signals. However, when emotion recognition systems are used for real-time classification, the training unit is frequently left to run offline or in the cloud rather than working locally on the edge. That strategy has hampered research, and the full potential of using an edge AI device has yet to be realized. Edge AI devices are computers with high performance that can process complex algorithms. It is capable of collecting, processing, and storing data on its own. It can also analyze and apply complicated algorithms like localization, detection, and recognition on a real-time application, making it a powerful embedded device. The NVIDIA Jetson series, specifically the Jetson Nano device, was used in the implementation. The cEEGrid, which is integrated to the open-source brain computer-interface platform (OpenBCI), is used to collect EEG signals. An EEG-based real-time emotion recognition system on Edge AI is proposed in this paper. To perform graphical spectrogram categorization of EEG signals and to predict emotional states based on input data properties, machine learning-based classifiers were used. Until the emotional state was identified, the EEG signals were analyzed using the K-Nearest Neighbor (KNN) technique, which is a supervised learning system. In EEG signal processing, after each EEG signal has been received in real-time and translated from time to frequency domain, the Fast Fourier Transform (FFT) technique is utilized to observe the frequency bands in each EEG signal. To appropriately show the variance of each EEG frequency band, power density, standard deviation, and mean are calculated and employed. The next stage is to identify the features that have been chosen to predict emotion in EEG data using the K-Nearest Neighbors (KNN) technique. Arousal and valence datasets are used to train the parameters defined by the KNN technique.Because classification and recognition of specific classes, as well as emotion prediction, are conducted both online and locally on the edge, the KNN technique increased the performance of the emotion recognition system on the NVIDIA Jetson Nano. Finally, this implementation aims to bridge the research gap on cost-effective and efficient real-time emotion recognition using a resource constrained hardware device, like the NVIDIA Jetson Nano. On the cutting edge of AI, EEG-based emotion identification can be employed in applications that can rapidly expand the research and implementation industry's use.

Keywords: edge AI device, EEG, emotion recognition system, supervised learning algorithm, sensors

Procedia PDF Downloads 96
3946 The Global-Local Dimension in Cognitive Control after Left Lateral Prefrontal Cortex Damage: Evidence from the Non-Verbal Domain

Authors: Eleni Peristeri, Georgia Fotiadou, Ianthi-Maria Tsimpli

Abstract:

The local-global dimension has been studied extensively in healthy controls and preference for globally processed stimuli has been validated in both the visual and auditory modalities. Critically, the local-global dimension has an inherent interference resolution component, a type of cognitive control, and left-prefrontal-cortex-damaged (LPFC) individuals have exhibited inability to override habitual response behaviors in item recognition tasks that involve representational interference. Eight patients with damage in the left PFC (age range: 32;5 to 69;0. Mean age: 54;6 yrs) and twenty age- and education-matched language-unimpaired adults (mean age: 56;7yrs) have participated in the study. Distinct performance patterns were found between the language-unimpaired and the LPFC-damaged group which have mainly stemmed from the latter’s difficulty with inhibiting global stimuli in incongruent trials. Overall, the local-global attentional dimension affects LPFC-damaged individuals with non-fluent aphasia in non-language domains implicating distinct types of inhibitory processes depending on the level of processing.

Keywords: left lateral prefrontal cortex damage (LPFC), local-global non-language attention, representational interference, non-fluent aphasia

Procedia PDF Downloads 457
3945 Modeling and Validation of Microspheres Generation in the Modified T-Junction Device

Authors: Lei Lei, Hongbo Zhang, Donald J. Bergstrom, Bing Zhang, K. Y. Song, W. J. Zhang

Abstract:

This paper presents a model for a modified T-junction device for microspheres generation. The numerical model is developed using a commercial software package: COMSOL Multiphysics. In order to test the accuracy of the numerical model, multiple variables, such as the flow rate of cross-flow, fluid properties, structure, and geometry of the microdevice are applied. The results from the model are compared with the experimental results in the diameter of the microsphere generated. The comparison shows a good agreement. Therefore the model is useful in further optimization of the device and feedback control of microsphere generation if any.

Keywords: CFD modeling, validation, microsphere generation, modified T-junction

Procedia PDF Downloads 687
3944 Design of a Lumbar Interspinous Process Fixation Device for Minimizing Soft Tissue Removal and Operation Time

Authors: Minhyuk Heo, Jihwan Yun, Seonghun Park

Abstract:

It has been reported that intervertebral fusion surgery, which removes most of the ligaments and muscles of the spine, increases the degenerative disease in adjacent spinal segments. Therefore, it is required to develop a lumbar interspinous process fixation device that minimizes the risks and side effects from the surgery. The objective of the current study is to design an interspinous process fixation device with simple structures in order to minimize soft tissue removal and operation time during intervertebral fusion surgery. For the design concepts of a lumbar fixation device, the principle of the ratchet was first applied on the joining parts of the device in order to shorten the operation time. The coil spring structure was selected for connecting parts between the spinous processes so that a normal range of motion in spinal segments is preserved and degenerative spinal diseases are not developed in the adjacent spinal segments. The stiffness of the spring was determined not to interrupt the motion of a lumbar spine. The designed value of the spring stiffness allows the upper part of the spring to move ~10° which is higher than the range of flexion and extension for normal lumbar spine (6°-8°), when a moment of 10Nm is applied on the upper face of L1. A finite element (FE) model composed of L1 to L5 lumbar spines was generated to verify the mechanical integrity and the dynamic stability of the designed lumbar fixation device and to further optimize the lumbar fixation device. The FE model generated above produced the same pressure value on intervertebral disc and dynamic behavior as the normal intact model reported in the literature. The consistent results from this comparison validates the accuracy in the modeling of the current FE model. Currently, we are trying to generate an abnormal model with defects in one or more components of the normal FE model above. Then, the mechanical integrity and the dynamic stability of the designed lumbar fixation device will be analyzed after being installed in the abnormal model and then the lumbar fixation device will be further optimized.

Keywords: lumbar interspinous process fixation device, finite element method, lumbar spine, kinematics

Procedia PDF Downloads 218
3943 Comparison of Dynamic Balance Ability and Flexibility in Different Sports

Authors: Inci Kesilmis, Manolya Akin, Mehmet Melih Kesilmis

Abstract:

The aim of this research was to compare dynamic balance ability (bipedal, right, left foot) and plantar-dorsi flexion range of motion in fencers and swimmers. 43 fencers participated as volunteer with mean age 15.74±1.90year and mean training year 4.97±2.37year. 25 swimmers participated as volunteer with mean age 15.36±1.65 yr. and mean training year 5.98±2.35 yr. Dynamic balance measured while participants were standing in the anatomical position with prokin tecno body for bipedal, right, left foot. Plantar and dorsal flexion range of motion measured while participants in seated position on the examination table and goniometer placed on the lateral malleolus. For statistical analyses; independent samples t test was used. There were significant differences between bipedal (p < 0.05), right foot (p < 0.05), left foot (p < 0.05) dynamic balance ability in favor of fencers. Also there was significant difference between right and left foot dorsal flexion range of motion (p < 0.001) in favor of fencers. There was no significant difference in plantar flexion range of motion between fencers and swimmers. The difference observed in fencers may be due to the use of more dorsal flexion in action moves and that swimming does not impact loading sport and it is performed in pool.

Keywords: fencing, swimming, dynamic balance, flexibility

Procedia PDF Downloads 363
3942 Alcohol Septal Ablation in a 19-Year-Old with Hypertrophic Obstructive Cardiomyopathy Patient: A Case Report

Authors: Christine Ysabelle G. Roman, Pauline Torres

Abstract:

Background: Hypertrophic cardiomyopathy is a disease of marked heterogeneity. It is a genetically determined heart disease characterized by significant myocardium hypertrophy that results in diastolic dysfunction, left ventricular outflow tract obstruction, and an increased risk of arrhythmias. The primary treatment in patients with such conditions is negative inotropic drugs, such as beta-blockers, calcium channel antagonists, and disopyramide. However, for those who remain symptomatic and need septal reduction therapy, surgical septal myectomy or alcohol septal ablation are options. Case Summary: A 19 – year old female presented in the authors’ institution with easy fatigability. The consult was done a year prior, and 2D echocardiography was requested which showed concentric left ventricular hypertrophy, asymmetrically hypertrophied interventricular septum (IVS) with the largest diameter of 3.3cm & subaortic dynamic obstruction with a maximum gradient of 47 mmHg. A repeat echo a year later showed asymmetric septal hypertrophy (IVS measuring at 3cm) with the systolic anterior motion of anterior mitral valve leaflet and left ventricular outflow tract obstruction (peak gradient of 50mmHg). The patient then underwent alcohol septal ablation and was discharged stable after four days of admission. Conclusion: Hypertrophic obstructive cardiomyopathy, a cardiovascular genetic disease, results in various patterns of left ventricular hypertrophy and abnormality of mitral valve apparatus. The patient is managed medically initially. However, despite optimal drug therapy and significant left ventricular outflow tract obstruction, significant heart failure symptoms or syncope require invasive treatment.

Keywords: hypertrophic obstructive cardiomyopathy, left ventricular outflow tract obstruction, alcohol septal ablation, alcohol

Procedia PDF Downloads 65
3941 Semi-Automatic Method to Assist Expert for Association Rules Validation

Authors: Amdouni Hamida, Gammoudi Mohamed Mohsen

Abstract:

In order to help the expert to validate association rules extracted from data, some quality measures are proposed in the literature. We distinguish two categories: objective and subjective measures. The first one depends on a fixed threshold and on data quality from which the rules are extracted. The second one consists on providing to the expert some tools in the objective to explore and visualize rules during the evaluation step. However, the number of extracted rules to validate remains high. Thus, the manually mining rules task is very hard. To solve this problem, we propose, in this paper, a semi-automatic method to assist the expert during the association rule's validation. Our method uses rule-based classification as follow: (i) We transform association rules into classification rules (classifiers), (ii) We use the generated classifiers for data classification. (iii) We visualize association rules with their quality classification to give an idea to the expert and to assist him during validation process.

Keywords: association rules, rule-based classification, classification quality, validation

Procedia PDF Downloads 424
3940 Computed Tomography Differential Diagnose of Intraventicular Masses in the Emergency Departemen

Authors: Angelis P. Barlampas

Abstract:

Purpose: A 29 years old woman presented in the emergency department with psychiatric symptoms. The psychiatrist ordered a computed tomography scan as part of a general examination. Material and methods: The CT showed bilateral enlarged choroid plexus structures mimicking papillomata and situated in the trigones of the lateral ventricles. The left choroid plexus was heavily calcified, but the right one has no any obvious calcifications. Results: It is well kown that any brain mass can present with behavioral changes and even psychiatric symptomatology. Papillomata of the ventricular system have been described to cause psychotic episodes. According to literature, choroid plexus papillomas are seldom neuroepithelial intraventricular tumors, which are benign and categorized as WHO grade 1 tumors. They are more common in the pediatric population, but they can occur in the adults, too1. In addition, the distinction between choroid plexus papilloma and carcinoma is very difficult and impossible by imagine alone. It can only be implied with more advanced imaging, such as arterial spin labeling and MRI. The final diagnosis is, of course, after surgical excision. The usual location in adults is the fourth ventricle, but in children, it is the lateral ventricles. Their imaging appearance is that of a solid vascular tumor, which enhances intensely after the intravenous administration of contrast material. One out of fourth tumors presents speckled calcifications1. In our case, there are symmetrically sized masses at the trigones, and there are no calcifications in one of them, whereas the other one is grossly calcified. Also, there is no obvious hydrocephalus or any other evidence of increased intracranial pressure. General conclusions: When there is a new psychiatric patient, someone must undergo any possible examination, and of course, a brain CT study should be done to exclude any rare organic causes that may be responsible for the disease.

Keywords: phycosis, intraventricular masses, CT, brain calcifications

Procedia PDF Downloads 51
3939 Children and Parents Left behind in Transnational Families: The Problem of Care Deficit

Authors: Joanna Bielecka-Prus

Abstract:

In the view of increasing number of labour migrations associated with broadly understood economic crisis, many families experience migration separation. Currently, in the era of globalization, migration movements include an increasing number of families, more and more frequently a new type of family, a transnational family. Accordingly, the functions of the family, family practice of care, and the relationships between members of the group change especially in the case of female migration. Sociologists highlight the emotional aspects of migrants’ family lives: managing emotions, coping with guilt, loneliness and rejection. Not without significance is the fact that today's public discourse often represents migrant women in a negative light. On the one hand, consumption and expanding material resources are assessed positively, on the other hand, deficits emotional and devastation of family life in the transnational families appear. Opinions expressed by different environments: the media, the political environment, etc. do not always take into account the context of mobility and their different effects on family life. The paper will present the analysis of qualitative studies of Polish female migrants’ families left-behind (children, parents, caregivers N = 100) and their coping strategies in different situations in the event of migration separation. The main area of care deficit will be defined and it will be showed who and how help to solve the problems.

Keywords: care, children left behind, female migration, parents left behind

Procedia PDF Downloads 381
3938 A New Aggregation Operator for Trapezoidal Fuzzy Numbers Based On the Geometric Means of the Left and Right Line Slopes

Authors: Manju Pandey, Nilay Khare, S. C. Shrivastava

Abstract:

This paper is the final in a series, which has defined two new classes of aggregation operators for triangular and trapezoidal fuzzy numbers based on the geometrical characteristics of their fuzzy membership functions. In the present paper, a new aggregation operator for trapezoidal fuzzy numbers has been defined. The new operator is based on the geometric mean of the membership lines to the left and right of the maximum possibility interval. The operator is defined and the analytical relationships have been derived. Computation of the aggregate is demonstrated with a numerical example. Corresponding arithmetic and geometric aggregates as well as results from the recent work of the authors on TrFN aggregates have also been computed.

Keywords: LR fuzzy number, interval fuzzy number, triangular fuzzy number, trapezoidal fuzzy number, apex angle, left apex angle, right apex angle, aggregation operator, arithmetic and geometric mean

Procedia PDF Downloads 454
3937 The Application of Collision Damage Analysis in Reconstruction of Sedan-Scooter Accidents

Authors: Chun-Liang Wu, Kai-Ping Shaw, Cheng-Ping Yu, Wu-Chien Chien, Hsiao-Ting Chen, Shao-Huang Wu

Abstract:

Objective: This study analyzed three criminal judicial cases. We applied the damage analysis of the two vehicles to verify other evidence, such as dashboard camera records of each accident, reconstruct the scenes, and pursue the truth. Methods: Evidence analysis, the method is to collect evidence and the reason for the results in judicial procedures, then analyze the involved damage evidence to verify other evidence. The collision damage analysis method is to inspect the damage to the vehicles and utilize the principles of tool mark analysis, Newtonian physics, and vehicle structure to understand the relevant factors when the vehicles collide. Results: Case 1: Sedan A turned right at the T junction and collided with Scooter B, which was going straight on the left road. The dashboard camera records showed that the left side of Sedan A’s front bumper collided with the body of Scooter B and rider B. After the analysis of the study, the truth was that the front of the left side of Sedan A impacted the right pedal of Scooter B and the right lower limb of rider B. Case 2: Sedan C collided with Scooter D on the left road at the crossroads. The dashboard camera record showed that the left side of the Sedan C’s front bumper collided with the body of Scooter D and rider D. After the analysis of the study, the truth was that the left side of the Sedan C impacted the left side of the car body and the front wheel of Scooter D and rider D. Case 3: Sedan E collided with Scooter F on the right road at the crossroads. The dashboard camera record showed that the right side of the Sedan E’s front bumper collided with the body of Scooter F and rider F. After the analysis of the study, the truth was that the right side of the front bumper and the right side of the Sedan F impacted the Scooter. Conclusion: The application of collision damage analysis in the reconstruction of a sedan-scooter collision could discover the truth and provide the basis for judicial justice. The cases and methods could be the reference for the road safety policy.

Keywords: evidence analysis, collision damage analysis, accident reconstruction, sedan-scooter collision, dashboard camera records

Procedia PDF Downloads 66
3936 Walking Progression in Ambulatory Individuals with Spinal Cord Injury Who Daily Walked with a Walking Device

Authors: Makamas Kumprou, Pipatana Amatachaya, Sugalya Amatachaya, Thiwabhorn Thaweewannakij, Preeda Arayawichanon

Abstract:

Many individuals with spinal cord injury (SCI) need an ambulatory assistive device (AAD) to promote their independence and experience of task-specific walking practice. Without a periodic follow-up for their walking progression, however, many individuals may use the same AAD even though up to 66% of them had the potential to progress walking ability. This may distort their optimal ability and increase the possibility of having negative impacts due to the long-lasting used of an AAD. However, these findings were cross-sectionally collected without data confirmation for the benefit or negative impacts of those who changed the types of AAD used. Therefore, this study prospectively assessed the proportion of ambulatory individuals with SCI who were able to progress their walking ability as determined using a type of AAD, and the changes of their functional ability as well as the incidence of falls over 6 months. Twenty-four subjects with SCI who daily walked with an AAD were involved in the study for 2 visits over 6 months. At the first visit (baseline assessments), the subjects were assessed for their spatiotemporal variables (i.e., cadence, step length, stride length, and step symmetry) and walking ability using the 10-meter walk test (10MWT). Then, they were assessed for the possibility of their walking progression as determined using the ability of walking with the least support AAD with no more than contact guarding assist. Those who were capable of changing an AAD were trained for the ability to walk with a new AAD. Thereafter, all subjects were monthly monitored for incidence of fall over 6 months. At the second visit (after 6 months followed-up), subjects were reassessed for their spatiotemporal variables and 10MWT. The findings indicated that, of all 24 subjects, 8 subjects (33.3%) were able to walk with less support AAD than their usual one. The walking cadence, step length symmetry, and walking ability of these subjects improved significantly greater than those who walked with the same AAD (p < 0.05). Among these subjects, one subject (12.5%) reported fell (3 times) during the follow-up period, whereas 5 subjects (31.3%) who walked with the same AAD experienced at least one fall (range 1 – 16 times). The findings indicated that a large proportion of ambulatory individuals with SCI who daily walked with an AAD could progress their walking ability, whereby their walking ability and safety also significantly improved after they walked with an optimal AAD. The findings suggest the need for a periodic follow-up for an appropriate AAD used for these individuals.

Keywords: walking device, walker, crutches, cane, rehabilitation

Procedia PDF Downloads 115
3935 Supporting Embedded Medical Software Development with MDevSPICE® and Agile Practices

Authors: Surafel Demissie, Frank Keenan, Fergal McCaffery

Abstract:

Emerging medical devices are highly relying on embedded software that runs on the specific platform in real time. The development of embedded software is different from ordinary software development due to the hardware-software dependency. MDevSPICE® has been developed to provide guidance to support such development. To increase the flexibility of this framework agile practices have been introduced. This paper outlines the challenges for embedded medical device software development and the structure of MDevSPICE® and suggests a suitable combination of agile practices that will help to add flexibility and address corresponding challenges of embedded medical device software development.

Keywords: agile practices, challenges, embedded software, MDevSPICE®, medical device

Procedia PDF Downloads 252
3934 College Readiness Outcomes of No Child Left Behind: A Critical Analysis

Authors: Tianyu Chen

Abstract:

The No Child Left Behind Act (NCLB) of 2001 was a major federal education policy that aimed to improve academic outcomes for all students in the United States. This study examines whether NCLB improved college readiness, measured by access to higher education, for different demographic groups. Using data from the Integrated Public Use Microdata Series (IPUMS) from 2003-2008, regression analyses explore the relationship between gender, race, family income, and region with occupational education score. The results indicate that NCLB implementation had a positive effect on college access for women and Asian students compared to other groups. Higher family income was also associated with an increased likelihood of pursuing higher education, especially for families in the South. While NCLB intended to close achievement gaps, disparities in college readiness remained five years after implementation. Further research could examine longer-term trends and additional factors influencing the policy's effectiveness across student subgroups. This study provides evidence that simply holding schools accountable for test scores may not sufficiently improve equitable educational outcomes. More targeted support of disadvantaged groups may be needed to fulfill the goal of "no child left behind."

Keywords: no child left behind act, college readiness, achievement gaps, educational equity

Procedia PDF Downloads 43
3933 Seismic Resistant Mechanism of Two-by-four Wooden Frame with Vibration Control Device

Authors: Takumi Ito, Kurumi Kurokawa, Dong Hang Wu, Takashi Nagumo, Haruhiko Hirata

Abstract:

The structural system of wooden house by two-by-four method is widely adopted in any countries, and a various type of vibration control system for building structures has been developed on country with frequent earthquake. In this study, a vibration control device called “Scaling Frame” (SF) is suggested, and which is applied to wooden two-by-four method structures. This paper performs the experimental study to investigate the restoring force characteristics of two-by-four with SF device installed. The seismic resistant performance is estimated experimentally, and also the applicability and effectiveness are discussing.

Keywords: two-by-four method, seismic vibration control, horizontally loading test, restoring force characteristics

Procedia PDF Downloads 281
3932 The Implementation of Special Grammar Circle (Spegraci) as the Media Innovation for Blind People to Learn English Tenses

Authors: Aji Budi Rinekso, Revika Niza Artiyana, Lisa Widayanti

Abstract:

English is one of the international languages in the world. People use this language to communicate with each other in the international forums, international events or international organizations. As same as other languages, English has a rule which is called grammar. Grammar is the part of english which has a role as the language systems. In grammar, there are tenses which provide a time period system for past, present and future. Sometimes it is difficult for some English learner to remember all of the tenses completely. Especially for those with special needs or exceptional children with vision restrictiveness. The aims of this research are 1) To know the design of Special Grammar Circle (Spegraci) as the media for blind people to learn english grammar. 2) To know the work of Special Gramar Circle (Spegraci) as the media for blind people to learn english grammar. 3) To know the function of this device in increasing tenses ability for blind people. The method of this research is Research and Development which consists of several testing and revision of this device. The implementation of Special Grammar Circle (Spegraci) is to make blind people easily to learn the tenses. This device is easy to use. Users only roll this device and find out the tense formula and match to the name of the formula in braille. In addition, this device also enables to be used by normal people because normal written texts are also provided.

Keywords: blind people, media innovation, spegraci, tenses

Procedia PDF Downloads 280
3931 Optical and Electrochromic Properties of All-Solid-State Electrochromic Device Consisting of Amorphous WO₃ and Ni(OH)₂

Authors: Ta-Huang Sun, Ming-Hao Hsieh, Min-Chuan Wang, Der-Jun Jan

Abstract:

Electrochromism refers to the persistent and reversible change of optical properties by an applied voltage pulse. There are many transition metal oxides exhibiting electrochromism, e.g. oxides of W, Ni, Ir, V, Ti, Co and Mo. Organic materials especially some conducting polymers such as poly(aniline), poly(3, 4-propylene- dioxythiophene) also received much attention for electrochromic (EC) applications. Electrochromic materials attract considerable interest because of their potential applications, such as information displays, smart windows, variable reflectance mirrors, and variable-emittance thermal radiators. In this study, the EC characteristics are investigated on an all-solid-state EC device composed of a-WO₃ and Ni(OH)₂ with a Ta₂O₅ protective layer which is prepared by magnetron sputtering. It is found that the transmittance modulation increases with decreasing the film thickness of Ta₂O₅. On the other hand, the transmittance modulation is 57% as the Ni(OH)₂/ITO is prepared by the linear-sweep potential cycling of the sputter-deposited Ta₂O₅/NiO/ITO in a 0.5 M LiClO₄+H₂O electrolyte. However, when Ni(OH)₂/ITO is prepared by a 0.01 M HCl electrolyte, the transmittance modulation of EC device can be improved to 61%.

Keywords: electrochromic device, tungsten oxide, nickel, Ta₂O₅

Procedia PDF Downloads 281
3930 Audio-Visual Entrainment and Acupressure Therapy for Insomnia

Authors: Mariya Yeldhos, G. Hema, Sowmya Narayanan, L. Dhiviyalakshmi

Abstract:

Insomnia is one of the most prevalent psychological disorders worldwide. Some of the deficiencies of the current treatments of insomnia are: side effects in the case of sleeping pills and high costs in the case of psychotherapeutic treatment. In this paper, we propose a device which provides a combination of audio visual entrainment and acupressure based compression therapy for insomnia. This device provides drug-free treatment of insomnia through a user friendly and portable device that enables relaxation of brain and muscles, with certain advantages such as low cost, and wide accessibility to a large number of people. Tools adapted towards the treatment of insomnia: -Audio -Continuous exposure to binaural beats of a particular frequency of audible range -Visual -Flash of LED light -Acupressure points -GB-20 -GV-16 -B-10

Keywords: insomnia, acupressure, entrainment, audio-visual entrainment

Procedia PDF Downloads 419
3929 Realizing the Rights of Prisoners with Disabilities in Nigeria: A Case Study of Four Lagos State Prisons

Authors: Jacob Bogart, Adaobi Egboka

Abstract:

Nigeria signed and ratified the Convention on the Rights of Persons with Disabilities in 2010, which was heralded as a much-needed step towards protecting the rights of persons with disabilities (PWDs). However, even with such progress, incarcerated PWDs have been left behind. The current legal framework in Nigeria does not consider the particular challenges PWDs face in prison nor make provisions to address them, despite the need for such reforms. Indeed, given the closed and restricted nature of prisons, and the violence that results from overcrowding, lack of supervision, and poor facilities, prisoners with disabilities often face significant challenges while incarcerated. While every prisoner is affected by these issues, PWDs are disproportionately harmed by them due to the nature of their disability. A study of four prisons in Lagos State, Nigeria was carried out by interviewing prisoners with disabilities, prison officials, advocates, and academics. The study found that for prisoners with physical disabilities, inaccessible prison facilities and a lack of mobility, hearing, or seeing assistance can often cause them to be dependent on the mercy of the other inmates for assistance in performing such basic functions as using the restroom, going to church, or washing themselves. Prison officials do not assist these PWDs or provide them with aids, such as crutches or a cane. Relatedly, prisoners with psychosocial disabilities (mental health conditions) often are not removed to health care facilities, despite a law to that effect, and are left to languish in prisons without the mental health care treatment they need. This presentation argues that reforms addressing the rights of PWDs must consider and make provisions for prisoners with disabilities, such as ensuring that prison facilities are accessible, providing PWDs with mobility, seeing or hearing aids as needed, and conducting mental health screenings for persons awaiting trial immediately upon entering the prison. These reforms, among others, are necessary first steps toward realizing the rights of prisoners with disabilities in Nigeria.

Keywords: disability rights, human rights, Lagos, Nigeria, prisoners with disabilities

Procedia PDF Downloads 339
3928 Solar-Powered Water Purification Using Ozone and Sand Filtration

Authors: Kayla Youhanaie, Kenneth Dott, Greg Gillis-Smith

Abstract:

Access to clean water is a global challenge that affects nearly one-third of the world’s population. A lack of safe drinking water negatively affects a person’s health, safety, and economic status. However, many regions of the world that face this clean water challenge also have high solar energy potential. To address this worldwide issue and utilize available resources, a solar-powered water purification device was developed that could be implemented in communities around the world that lack access to potable water. The device uses ozone to destroy water-borne pathogens and sand filtration to filter out particulates from the water. To select the best method for this application, a quantitative energy efficiency comparison of three water purification methods was conducted: heat, UV light, and ozone. After constructing an initial prototype, the efficacy of the device was tested using agar petri dishes to test for bacteria growth in treated water samples at various time intervals after applying the device to contaminated water. The results demonstrated that the water purification device successfully removed all bacteria and particulates from the water within three minutes, making it safe for human consumption. These results, as well as the proposed design that utilizes widely available resources in target communities, suggest that the device is a sustainable solution to address the global water crisis and could improve the quality of life for millions of people worldwide.

Keywords: clean water, solar powered water purification, ozonation, sand filtration, global water crisis

Procedia PDF Downloads 59
3927 A Simple Device for in-Situ Direct Shear and Sinkage Tests

Authors: A. Jerves, H. Ling, J. Gabaldon, M. Usoltceva, C. Couste, A. Agarwal, R. Hurley, J. Andrade

Abstract:

This work introduces a simple device designed to perform in-situ direct shear and sinkage tests on granular materials as sand, clays, or regolith. It consists of a box nested within a larger box. Both have open bottoms, allowing them to be lowered into the material. Afterwards, two rotating plates on opposite sides of the outer box will rotate outwards in order to clear regolith on either side, providing room for the inner box to move relative to the plates and perform a shear test without the resistance of the surrounding soil. From this test, Coulomb parameters, including cohesion and internal friction angle, as well as, Bekker parameters can be in erred. This device has been designed for a laboratory setting, but with few modi cations, could be put on the underside of a rover for use in a remote location. The goal behind this work is to ultimately create a compact, but accurate measuring tool to put onto a rover or any kind of exploratory vehicle to test for regolith properties of celestial bodies.

Keywords: simple shear, friction angle, Bekker parameters, device, regolith

Procedia PDF Downloads 497
3926 Case Report of Left Atrial Myxoma Diagnosed by Bedside Echocardiography

Authors: Anthony S. Machi, Joseph Minardi

Abstract:

We present a case report of left atrial myxoma diagnosed by bedside transesophageal (TEE) ultrasound. Left atrial myxoma is the most common benign cardiac tumor and can obstruct blood flow and cause valvular insufficiency. Common symptoms consist of dyspnea, pulmonary edema and other features of left heart failure in addition to thrombus release in the form of tumor fragments. The availability of bedside ultrasound equipment is essential for the quick diagnosis and treatment of various emergency conditions including cardiac neoplasms. A 48-year-old Caucasian female with a four-year history of an untreated renal mass and anemia presented to the ED with two months of sharp, intermittent, bilateral flank pain radiating into the abdomen. She also reported intermittent vomiting and constipation along with generalized body aches, night sweats, and 100-pound weight loss over last year. She had a CT in 2013 showing a 3 cm left renal mass and a second CT in April 2016 showing a 3.8 cm left renal mass along with a past medical history of diverticulosis, chronic bronchitis, dyspnea on exertion, uncontrolled hypertension, and hyperlipidemia. Her maternal family history is positive for breast cancer, hypertension, and Type II Diabetes. Her paternal family history is positive for stroke. She was a current everyday smoker with an 11 pack/year history. Alcohol and drug use were denied. Physical exam was notable for a Grade II/IV systolic murmur at the right upper sternal border, dyspnea on exertion without angina, and a tender left lower quadrant. Her vitals and labs were notable for a blood pressure of 144/96, heart rate of 96 beats per minute, pulse oximetry of 96%, hemoglobin of 7.6 g/dL, hypokalemia, hypochloremia, and multiple other abnormalities. Physicians ordered a CT to evaluate her flank pain which revealed a 7.2 x 8.9 x 10.5 cm mixed cystic/solid mass in the lower pole of the left kidney and a filling defect in the left atrium. Bedside TEE was ordered to follow up on the filling defect. TEE reported an ejection fraction of 60-65% and visualized a mobile 6 x 3 cm mass in the left atrium attached to the interatrial septum extending into the mitral valve. Cardiothoracic Surgery and Urology were consulted and confirmed a diagnosis of left atrial myxoma and clear cell renal cell carcinoma. The patient returned a week later due to worsening nausea and vomiting and underwent emergent nephrectomy, lymph node dissection, and colostomy due to a necrotic colon. Her condition declined over the next four months due to lung and brain metastases, infections, and other complications until she passed away.

Keywords: bedside ultrasound, echocardiography, emergency medicine, left atrial myxoma

Procedia PDF Downloads 317
3925 Predictors and 3-Year Outcomes of Compromised Left Circumflex Coronary Artery After Left Main Crossover Stenting

Authors: Hameed Ullah, Karim Elakabawi, Han KE, Najeeb Ullah, Habib Ullah, Sardar Ali Shah, Hamad Haider Khan, Muhammad Asad Khan, Ning Guo, Zuyi Yuan

Abstract:

Background: Predictors of decreased fractional flow reserve at left circumflex coronary artery after left main (LM) crossover stenting are still lacking. The objectives of the present study were to provide the predictors for low Fractional flow reserve (FFR) at coronary artery (LCx) and the possible treatment strategies for the compromised LCx-together with their long term outcomes. Methods: A total of 563 included patients out of 1974 patients admitted to our hospital from February 2015 to November 2020 with significant distal LM-bifurcation lesions. The enrolled patients underwent single-stent cross-over PCI under IVUS guidance with further LCx intervention as indicated by measured FFR. Results: The included patients showed angiographic significant LCx ostial affection after LM-stenting, but only 116 (20.6%) patients had FFR <0.8. The 3-year composite MACE rates were comparable between the high and low FFR groups (16.8% vs. 15.5%, respectively; P=0.744). In a multivariable analysis, a low FFR in the LCx was associated with post-stenting MLA of the LCx (OR: 0.032, P <0.001), post-stenting LCx-plaque burden (OR: 1.166, P <0.001), post-stenting LM-MLA (OR: 0.821, P =0.038) and pre-stenting LCx-MLA (OR: 0.371, P =0.044). In patients with low FFR, management of compromised LCx with DEB had the lowest 3-year MACE rate (8.1%) as compared to either KBI (17.5%) or stenting group (20.5%), P =0.299. Conclusion: FFR-guided LCx intervention can avoid unnecessary LCx intervention. The post-stenting predictors of low FFR include post-stenting MLA and plaque burden of the LCx and MV stent length. The 3-year MACE rates were comparable between high FFR patients and patients who had low FFR and were adequately managed.

Keywords: fractional flow reserve, left main stem, percutaneous coronary interventions, intravascular ultrasound

Procedia PDF Downloads 27