Search results for: brain ultrasound
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1579

Search results for: brain ultrasound

1519 Mechanical Prosthesis Controlled by Brain-Computer Interface

Authors: Tianyu Cao, KIRA (Ruizhi Zhao)

Abstract:

The purpose of our research is to study the possibility of people with physical disabilities manipulating mechanical prostheses through brain-computer interface (BCI) technology. The brain-machine interface (BCI) of the neural prosthesis records signals from neurons and uses mathematical modeling to decode them, converting desired movements into body movements. In order to improve the patient's neural control, the prosthesis is given a natural feeling. It records data from sensitive areas from the body to the prosthetic limb and encodes signals in the form of electrical stimulation to the brain. In our research, the brain-computer interface (BCI) is a bridge connecting patients’ cognition and the real world, allowing information to interact with each other. The efficient work between the two is achieved through external devices. The flow of information is controlled by BCI’s ability to record neuronal signals and decode signals, which are converted into device control. In this way, we could encode information and then send it to the brain through electrical stimulation, which has significant medical application.

Keywords: biomedical engineering, brain-computer interface, prosthesis, neural control

Procedia PDF Downloads 145
1518 Ultrasonic Measurement of Elastic Properties of Fiber Reinforced Composite Materials

Authors: Hatice Guzel, Imran Oral, Huseyin Isler

Abstract:

In this study, elastic constants, Young’s modulus, Poisson’s ratios, and shear moduli of orthotropic composite materials, consisting of E-glass/epoxy and carbon/epoxy, were calculated by ultrasonic velocities which were measured using ultrasonic pulse-echo method. 35 MHz computer controlled analyzer, 60 MHz digital oscilloscope, 5 MHz longitudinal probe, and 2,25 MHz transverse probe were used for the measurements of ultrasound velocities, the measurements were performed at ambient temperature. It was understood from the data obtained in this study that, measured ultrasound velocities and the calculated elasticity coefficients were depending on the fiber orientations.

Keywords: composite materials, elastic constants, orthotropic materials, ultrasound

Procedia PDF Downloads 262
1517 Detecting Rat’s Kidney Inflammation Using Real Time Photoacoustic Tomography

Authors: M. Y. Lee, D. H. Shin, S. H. Park, W.C. Ham, S.K. Ko, C. G. Song

Abstract:

Photoacoustic Tomography (PAT) is a promising medical imaging modality that combines optical imaging contrast with the spatial resolution of ultrasound imaging. It can also distinguish the changes in biological features. But, real-time PAT system should be confirmed due to photoacoustic effect for tissue. Thus, we have developed a real-time PAT system using a custom-developed data acquisition board and ultrasound linear probe. To evaluate performance of our system, phantom test was performed. As a result of those experiments, the system showed satisfactory performance and its usefulness has been confirmed. We monitored the degradation of inflammation which induced on the rat’s kidney using real-time PAT.

Keywords: photoacoustic tomography, inflammation detection, rat, kidney, contrast agent, ultrasound

Procedia PDF Downloads 420
1516 Elastic Constants of Fir Wood Using Ultrasound and Compression Tests

Authors: Ergun Guntekin

Abstract:

Elastic constants of Fir wood (Abies cilicica) have been investigated by means of ultrasound and compression tests. Three modulus of elasticity in principal directions (EL, ER, ET), six Poisson’s ratios (ʋLR, ʋLT, ʋRT, ʋTR, ʋRL, ʋTL) and three shear modules (GLR, GRT, GLT) were determined. 20 x 20 x 60 mm samples were conditioned at 65 % relative humidity and 20ºC before testing. Three longitudinal and six shear wave velocities propagating along the principal axes of anisotropy, and additionally, three quasi-shear wave velocities at 45° angle with respect to the principal axes of anisotropy were measured. 2.27 MHz longitudinal and 1 MHz shear sensors were used for obtaining sound velocities. Stress-strain curves of the samples in compression tests were obtained using bi-axial extensometer in order to calculate elastic constants. Test results indicated that most of the elastic constants determined in the study are within the acceptable range. Although elastic constants determined from ultrasound are usually higher than those determined from compression tests, the values of EL and GLR determined from compression tests were higher in the study. The results of this study can be used in the numerical modeling of elements or systems under load using Fir wood.

Keywords: compression tests, elastic constants, fir wood, ultrasound

Procedia PDF Downloads 191
1515 Brain Tumor Detection and Classification Using Pre-Trained Deep Learning Models

Authors: Aditya Karade, Sharada Falane, Dhananjay Deshmukh, Vijaykumar Mantri

Abstract:

Brain tumors pose a significant challenge in healthcare due to their complex nature and impact on patient outcomes. The application of deep learning (DL) algorithms in medical imaging have shown promise in accurate and efficient brain tumour detection. This paper explores the performance of various pre-trained DL models ResNet50, Xception, InceptionV3, EfficientNetB0, DenseNet121, NASNetMobile, VGG19, VGG16, and MobileNet on a brain tumour dataset sourced from Figshare. The dataset consists of MRI scans categorizing different types of brain tumours, including meningioma, pituitary, glioma, and no tumour. The study involves a comprehensive evaluation of these models’ accuracy and effectiveness in classifying brain tumour images. Data preprocessing, augmentation, and finetuning techniques are employed to optimize model performance. Among the evaluated deep learning models for brain tumour detection, ResNet50 emerges as the top performer with an accuracy of 98.86%. Following closely is Xception, exhibiting a strong accuracy of 97.33%. These models showcase robust capabilities in accurately classifying brain tumour images. On the other end of the spectrum, VGG16 trails with the lowest accuracy at 89.02%.

Keywords: brain tumour, MRI image, detecting and classifying tumour, pre-trained models, transfer learning, image segmentation, data augmentation

Procedia PDF Downloads 41
1514 Effect of Ultrasound on Carotenoids Extraction from Pepper and Process Optimization Using Response Surface Methodology (RSM)

Authors: Elham Mahdian, Reza Karazhian, Rahele Dehghan Tanha

Abstract:

Pepper (Capsicum annum L.) which belong to the family Solananceae, are known for their versatility as a vegetable crop and are consumed both as fresh vegetables or dehydrated for spices. Pepper is considered an excellent source of bioactive nutrients. Ascorbic acid, carotenoids and phenolic compounds are its main antioxidant constituents. Ultrasound assisted extraction is an inexpensive, simple and efficient alternative to conventional extraction techniques. The mechanism of action for ultrasound-assisted extraction are attributed to cavitations, mechanical forces and thermal impact, which result in disruption of cells walls, reduce particle size, and enhance mass transfer across cell membranes. In this study, response surface methodology was used to optimize experimental conditions for ultrasonic assisted extraction of carotenoid compounds from Chili peppers. Variables were included extraction temperatures at 3 levels (30, 40 and 50 °C), extraction times at 3 levels (10, 25 and 40 minutes) and power at 3 levels (30, 60 and 90 %). It was observed that ultrasound waves applied at temperature of 49°C, time of 10 minutes and power 89 % resulted to the highest carotenoids contents (lycopene and β-carotene), while the lowest value was recorded in the control. Thus, results showed that ultrasound waves have strong impact on extraction of carotenoids from pepper.

Keywords: carotenoids, optimization, pepper, response surface methodology

Procedia PDF Downloads 439
1513 A DOE Study of Ultrasound Intensified Removal of Phenol

Authors: P. R. Rahul, A. Kannan

Abstract:

Ultrasound-aided adsorption of phenol by Granular Activated Carbon (GAC) was investigated at different frequencies ranging from 35 kHz, 58 kHz, and 192 kHz. Other factors influencing adsorption such as Adsorbent dosage (g/L), the initial concentration of the phenol solution (ppm) and RPM was also considered along with the frequency variable. However, this study involved calorimetric measurements which helped is determining the effect of frequency on the % removal of phenol from the power dissipated to the system was normalized. It was found that low frequency (35 kHz) cavitation effects had a profound influence on the % removal of phenol per unit power. This study also had cavitation mapping of the ultrasonic baths, and it showed that the effect of cavitation on the adsorption system is irrespective of the position of the vessel. Hence, the vessel was placed at the center of the bath. In this study, novel temperature control and monitoring system to make sure that the system is under proper condition while operations. From the BET studies, it was found that there was only 5% increase in the surface area and hence it was concluded that ultrasound doesn’t profoundly alter the equilibrium value of the adsorption system. DOE studies indicated that adsorbent dosage has a higher influence on the % removal in comparison with other factors.

Keywords: ultrasound, adsorption, granulated activated carbon, phenol

Procedia PDF Downloads 262
1512 Meditation Based Brain Painting Promotes Foreign Language Memory through Establishing a Brain-Computer Interface

Authors: Zhepeng Rui, Zhenyu Gu, Caitilin de Bérigny

Abstract:

In the current study, we designed an interactive meditation and brain painting application to cultivate users’ creativity, promote meditation, reduce stress, and improve cognition while attempting to learn a foreign language. User tests and data analyses were conducted on 42 male and 42 female participants to better understand sex-associated psychological and aesthetic differences. Our method utilized brain-computer interfaces to import meditation and attention data to create artwork in meditation-based applications. Female participants showed statistically significantly different language learning outcomes following three meditation paradigms. The art style of brain painting helped females with language memory. Our results suggest that the most ideal methods for promoting memory attention were meditation methods and brain painting exercises contributing to language learning, memory concentration promotion, and foreign word memorization. We conclude that a short period of meditation practice can help in learning a foreign language. These findings provide new insights into meditation, creative language education, brain-computer interface, and human-computer interactions.

Keywords: brain-computer interface, creative thinking, meditation, mental health

Procedia PDF Downloads 94
1511 Osteoarticular Ultrasound for Diagnostic Purposes in the Practice of the Rheumatologist

Authors: A. Ibovi Mouondayi, S. Zaher, K. Nassar, S. Janani

Abstract:

Introduction: Osteoarticular ultrasound has become an essential tool for the investigation and monitoring of osteoarticular pathologies for rheumatologists. It is performed in the clinic, cheap to access than other imaging technics. Important anatomical sites of inflammation in inflammatory diseases such as synovium, tendon sheath, and enthesis are easily identifiable on ultrasound. Objective: The objective of this study was to evaluate the importance of ultrasound for rheumatologists in the development of diagnoses of inflammatory rheumatism in cases of uncertain clinical presentation. Material and Methods: This is a retrospective study conducted in our department and carried out over a period of 30 months from January 2020 to June 2022. We included all patients with inflammatory arthralgia without clinical arthritis. Patients' data were collected through a patient operating system. Results: A total of 35 patients were identified, made up of 4 men and 31 women, with a sex ratio M/F of 0.12. The average age of the patients was 48.8 years, with extremes ranging from 17 years to 83 years. All patients had inflammatory polyarthralgia for an average of 9.3 years. Only two patients had suspicious synovitis on clinical examination. 91.43% of patients had a positive inflammatory assessment with an average CRP of 22.2 mg/L. Rheumatoid factor (RF) was present in 45.7% of patients and anti-CCP in 48.57%, with respective averages of 294.43 and 314.63 international units/mL. Radiographic lesions were found in 54% of patients. Osteoarticular ultrasound was performed in all these patients. Subclinical synovitis was found in 60% of patients, including 23% Doppler positive. Tenosynovitis was found in 11% of patients. Enthesitis was objectified in 3% of patients. Rheumatoid arthritis (RA) was retained in 40% of patients; psoriatic arthritis in 6% of patients, hydroxyapatite arthritis, and osteoarthritis in 3% each. Conclusion: Osteoarticular ultrasound has been an essential tool in the practice of rheumatology in recent years. It is for diagnostic purposes in chronic inflammatory rheumatism as well as in degenerative rheumatism and crystal induced arthropathies, but also essential in the follow-up of patients in rheumatology.

Keywords: ultrasound, skeletal, rheumatoid arthritis, arthralgia

Procedia PDF Downloads 90
1510 The Effect of Ultrasound Pretreatment on Bioactive Compounds of Freeze-Dried Carrots

Authors: Gulcin Yildiz

Abstract:

Although drying is one of the most prevalent techniques applied to enhance food stability, it is a complicated method covering simultaneous coupled heat and mass transfer phenomena and the theoretical application of these phenomena to food products becomes challenging because of the complex structure and to the physical and chemical changes that happen at drying. Pretreatment of materials before drying has been shown to be effective in solving drying problems such as long drying times and poor product quality. The study was conducted to examine the effect of ultrasound (US) pre-treatment on physical and chemical/nutritional attributes of freeze-dried carrot slices. The carrots were washed, hand-peeled, and cut with dimensions of 1 cm (L) x 0.2 (W) cm x 1 cm (H). The carrot samples were treated in an ultrasonic bath in two different times, which were 15 and 30 minutes. Untreated and ultrasound pre-treated carrot samples were dried in a freeze dryer. Freeze-dried samples were analyzed in terms of bioactive compounds, including total phenols, ascorbic acid, and antioxidant capacity. Significant differences were found among dried carrot samples with and without ultrasound. The freeze-dried carrot slices treated with a US (especially 30 minutes - treatment) showed higher preservation of bioactive compounds. In overall, US pretreatment is a promising process, as demonstrated in current research by its capability to better retain freeze-dried carrot quality.

Keywords: bioactive compounds, carrot, freeze drying, ultrasound-pretreatment

Procedia PDF Downloads 93
1509 Dual-Channel Reliable Breast Ultrasound Image Classification Based on Explainable Attribution and Uncertainty Quantification

Authors: Haonan Hu, Shuge Lei, Dasheng Sun, Huabin Zhang, Kehong Yuan, Jian Dai, Jijun Tang

Abstract:

This paper focuses on the classification task of breast ultrasound images and conducts research on the reliability measurement of classification results. A dual-channel evaluation framework was developed based on the proposed inference reliability and predictive reliability scores. For the inference reliability evaluation, human-aligned and doctor-agreed inference rationals based on the improved feature attribution algorithm SP-RISA are gracefully applied. Uncertainty quantification is used to evaluate the predictive reliability via the test time enhancement. The effectiveness of this reliability evaluation framework has been verified on the breast ultrasound clinical dataset YBUS, and its robustness is verified on the public dataset BUSI. The expected calibration errors on both datasets are significantly lower than traditional evaluation methods, which proves the effectiveness of the proposed reliability measurement.

Keywords: medical imaging, ultrasound imaging, XAI, uncertainty measurement, trustworthy AI

Procedia PDF Downloads 61
1508 [Keynote Talk]: Ultrasound Assisted Synthesis of ZnO of Different Morphologies by Solvent Variation

Authors: Durata Haciu, Berti Manisa, Ozgur Birer

Abstract:

ZnO nanoparticles have been synthesized by ultrasonic irradiation from simple linear alcohols and water/ethanolic mixtures, at 50 oC. By changing the composition of the solvent, the shape could be altered. While no product was obtained from methanolic solutions, in ethanol, sheet like lamellar structures prevail.n-propanol and n-butanol resulted in needle like structures. The morphology of ZnO could be thus tailored in a simple way, by varying the solvent, under ultrasonic irradiation, in a relatively less time consuming method. Variation of the morphology and size of Zn also provides a means for modulating the band-gap. Although the chemical effects of ultrasound do not come from direct interaction with molecular species, the high energy derived from acoustic cavitation creates a unique interaction of energy and matter with great potential for synthesis.

Keywords: ultrasound, ZnO, linear alcohols, morphology

Procedia PDF Downloads 218
1507 Ultrasound Assisted Extraction and Microwave Assisted Extraction of Carotenoids from Melon Shells

Authors: A. Brinda Lakshmi, J. Lakshmi Priya

Abstract:

Cantaloupes (muskmelon and watermelon) contain biologically active molecules such as carotenoids which are natural pigments used as food colorants and afford health benefits. ß-carotene is the major source of carotenoids present in muskmelon and watermelon shell. Carotenoids were extracted using Microwave assisted extraction (MAE) and Ultrasound assisted extraction (UAE) utilising organic lipophilic solvents such as acetone, methanol, and hexane. Extraction conditions feed-solvent ratio, microwave power, ultrasound frequency, temperature and particle size were varied and optimized. It was found that the yield of carotenoids was higher using UAE than MAE, and muskmelon had the highest yield of carotenoids when was ethanol used as a solvent for 0.5 mm particle size.

Keywords: carotenoids, extraction, muskmelon shell, watermelon shell

Procedia PDF Downloads 239
1506 Magnetic Resonance Imaging in Children with Brain Tumors

Authors: J. R. Ashrapov, G. A. Alihodzhaeva, D. E. Abdullaev, N. R. Kadirbekov

Abstract:

Diagnosis of brain tumors is one of the challenges, as several central nervous system diseases run the same symptoms. Modern diagnostic techniques such as CT, MRI helps to significantly improve the surgery in the operating period, after surgery, after allowing time to identify postoperative complications in neurosurgery. Purpose: To study the MRI characteristics and localization of brain tumors in children and to detect the postoperative complications in the postoperative period. Materials and methods: A retrospective study of treatment of 62 children with brain tumors in age from 2 to 5 years was performed. Results of the review: MRI scan of the brain of the 62 patients 52 (83.8%) case revealed a brain tumor. Distribution on MRI of brain tumors found in 15 (24.1%) - glioblastomas, 21 (33.8%) - astrocytomas, 7 (11.2%) - medulloblastomas, 9 (14.5%) - a tumor origin (craniopharyngiomas, chordoma of the skull base). MRI revealed the following characteristic features: an additional sign of the heterogeneous MRI signal of hyper and hypointensive T1 and T2 modes with a different perifocal swelling degree with involvement in the process of brain vessels. The main objectives of postoperative MRI study are the identification of early or late postoperative complications, evaluation of radical surgery, the identification of the extended-growing tumor that (in terms of 3-4 weeks). MRI performed in the following cases: 1. Suspicion of a hematoma (3 days or more) 2. Suspicion continued tumor growth (in terms of 3-4 weeks). Conclusions: Magnetic resonance tomography is a highly informative method of diagnostics of brain tumors in children. MRI also helps to determine the effectiveness and tactics of treatment and the follow up in the postoperative period.

Keywords: brain tumors, children, MRI, treatment

Procedia PDF Downloads 115
1505 Brain-Motor Disablement: Using Virtual Reality-Based Therapeutic Simulations

Authors: Vince Macri, Jakub Petioky, Paul Zilber

Abstract:

Virtual-reality-based technology, i.e. video-game-like simulations (collectively, VRSims) are used in therapy for a variety of medical conditions. The purpose of this paper is to contribute to a discussion on criteria for selecting VRSims to augment treatment of survivors of acquired brain injury. Specifically, for treatments to improve or restore brain motor function in upper extremities affected by paresis or paralysis. Six uses of virtual reality are reviewed video games for entertainment, training simulations, unassisted or device-assisted movements of affected or unaffected extremities displayed in virtual environments and virtual anatomical interactivity.

Keywords: acquired brain injury, brain-motor function, virtual anatomical interactivity, therapeutic simulations

Procedia PDF Downloads 556
1504 The Contribution of Density Fluctuations in Ultrasound Scattering in Cancellous Bone

Authors: A. Elsariti, T. Evans

Abstract:

An understanding of the interaction between acoustic waves and cancellous bone is needed in order to realize the full clinical potential of ultrasonic bone measurements. Scattering is likely to be of central importance but has received little attention to date. Few theoretical approaches have been described to explain scattering of ultrasound from bone. In this study, a scattering model based on velocity and density fluctuations in a binary mixture (marrow fat and cortical matrix) was used to estimate the ultrasonic attenuation in cancellous bone as a function of volume fraction. Predicted attenuation and backscatter coefficient were obtained for a range of porosities and scatterer size. At 600 kHZ and for different scatterer size the effect of velocity and density fluctuations in the predicted attenuation was approximately 60% higher than velocity fluctuations.

Keywords: ultrasound scattering, sound speed, density fluctuations, attenuation coefficient

Procedia PDF Downloads 302
1503 Clinical Trial of VEUPLEXᵀᴹ TBI Assay to Help Diagnose Traumatic Brain Injury by Quantifying Glial Fibrillary Acidic Protein and Ubiquitin Carboxy-Terminal Hydrolase L1 in the Serum of Patients Suspected of Mild TBI by Fluorescence Immunoassay

Authors: Moon Jung Kim, Guil Rhim

Abstract:

The clinical sensitivity of the “VEUPLEXTM TBI assay”, a clinical trial medical device, in mild traumatic brain injury was 28.6% (95% CI, 19.7%-37.5%), and the clinical specificity was 94.0% (95% CI, 89.3%). -98.7%). In addition, when the results analyzed by marker were put together, the sensitivity was higher when interpreting the two tests together than the two tests, UCHL1 and GFAP alone. Additionally, when sensitivity and specificity were analyzed based on CT results for the mild traumatic brain injury patient group, the clinical sensitivity for 2 CT-positive cases was 50.0% (95% CI: 1.3%-98.7%), and 19 CT-negative cases. The clinical specificity for cases was 68.4% (95% CI: 43.5% - 87.4%). Since the low clinical sensitivity for the two CT-positive cases was not statistically significant due to the small number of samples analyzed, it was judged necessary to secure and analyze more samples in the future. Regarding the clinical specificity analysis results for 19 CT-negative cases, there were a large number of patients who were actually clinically diagnosed with mild traumatic brain injury but actually received a CT-negative result, and about 31.6% of them showed abnormal results on VEUPLEXTM TBI assay. Although traumatic brain injury could not be detected in 31.6% of the CT scans, the possibility of actually suffering a mild brain injury could not be ruled out, so it was judged that this could be confirmed through follow-up observation of the patient. In addition, among patients with mild traumatic brain injury, CT examinations were not performed in many cases because the symptoms were very mild, but among these patients, about 25% or more showed abnormal results in the VEUPLEXTM TBI assay. In fact, no damage is observed with the naked eye immediately after traumatic brain injury, and traumatic brain injury is not observed even on CT. But in some cases, brain hemorrhage may occur (delayed cerebral hemorrhage) after a certain period of time, so the patients who did show abnormal results on VEUPLEXTM TBI assay should be followed up for the delayed cerebral hemorrhage. In conclusion, it was judged that it was difficult to judge mild traumatic brain injury with the VEUPLEXTM TBI assay only through clinical findings without CT results, that is, based on the GCS value. Even in the case of CT, it does not detect all mild traumatic brain injury, so it is difficult to necessarily judge that there is no traumatic brain injury, even if there is no evidence of traumatic brain injury in CT. And in the long term, more patients should be included to evaluate the usefulness of the VEUPLEXTM TBI assay in the detection of microscopic traumatic brain injuries without using CT.

Keywords: brain injury, traumatic brain injury, GFAP, UCHL1

Procedia PDF Downloads 54
1502 Comparison of Back-Projection with Non-Uniform Fast Fourier Transform for Real-Time Photoacoustic Tomography

Authors: Moung Young Lee, Chul Gyu Song

Abstract:

Photoacoustic imaging is the imaging technology that combines the optical imaging and ultrasound. This provides the high contrast and resolution due to optical imaging and ultrasound imaging, respectively. We developed the real-time photoacoustic tomography (PAT) system using linear-ultrasound transducer and digital acquisition (DAQ) board. There are two types of algorithm for reconstructing the photoacoustic signal. One is back-projection algorithm, the other is FFT algorithm. Especially, we used the non-uniform FFT algorithm. To evaluate the performance of our system and algorithms, we monitored two wires that stands at interval of 2.89 mm and 0.87 mm. Then, we compared the images reconstructed by algorithms. Finally, we monitored the two hairs crossed and compared between these algorithms.

Keywords: back-projection, image comparison, non-uniform FFT, photoacoustic tomography

Procedia PDF Downloads 410
1501 Estimation of Endogenous Brain Noise from Brain Response to Flickering Visual Stimulation Magnetoencephalography Visual Perception Speed

Authors: Alexander N. Pisarchik, Parth Chholak

Abstract:

Intrinsic brain noise was estimated via magneto-encephalograms (MEG) recorded during perception of flickering visual stimuli with frequencies of 6.67 and 8.57 Hz. First, we measured the mean phase difference between the flicker signal and steady-state event-related field (SSERF) in the occipital area where the brain response at the flicker frequencies and their harmonics appeared in the power spectrum. Then, we calculated the probability distribution of the phase fluctuations in the regions of frequency locking and computed its kurtosis. Since kurtosis is a measure of the distribution’s sharpness, we suppose that inverse kurtosis is related to intrinsic brain noise. In our experiments, the kurtosis value varied among subjects from K = 3 to K = 5 for 6.67 Hz and from 2.6 to 4 for 8.57 Hz. The majority of subjects demonstrated leptokurtic kurtosis (K < 3), i.e., the distribution tails approached zero more slowly than Gaussian. In addition, we found a strong correlation between kurtosis and brain complexity measured as the correlation dimension, so that the MEGs of subjects with higher kurtosis exhibited lower complexity. The obtained results are discussed in the framework of nonlinear dynamics and complex network theories. Specifically, in a network of coupled oscillators, phase synchronization is mainly determined by two antagonistic factors, noise, and the coupling strength. While noise worsens phase synchronization, the coupling improves it. If we assume that each neuron and each synapse contribute to brain noise, the larger neuronal network should have stronger noise, and therefore phase synchronization should be worse, that results in smaller kurtosis. The described method for brain noise estimation can be useful for diagnostics of some brain pathologies associated with abnormal brain noise.

Keywords: brain, flickering, magnetoencephalography, MEG, visual perception, perception time

Procedia PDF Downloads 114
1500 The Interaction between Blood-Brain Barrier and the Cerebral Lymphatics Proposes Therapeutic Method for Alzheimer’S Disease

Authors: M. Klimova, O. Semyachkina-Glushkovskaya, J. Kurts, E. Zinchenko, N. Navolokin, A. Shirokov, A. Dubrovsky, A. Abdurashitov, A. Terskov, A. Mamedova, I. Agranovich, T. Antonova, I. Blokhina

Abstract:

The direction for research of Alzheimer's disease is to find an effective non-invasive and non-pharmacological way of treatment. Here we tested our hypothesis that the opening of the blood-brain barrier (BBB) induces activation of lymphatic drainage and clearing functions that can be used as a method for non-invasive stimulation of clearance of beta-amyloid and therapy of Alzheimer’s disease (AD). To test our hypothesis, in this study on healthy male mice we analyzed the interaction between BBB opening by repeated loud music (100-10000 Hz, 100 dB, duration 2 h: 60 sec – sound; 60 sec - pause) and functional changes in the meningeal lymphatic vessels (MLVs). We demonstrate clearance of dextran 70 kDa (i.v. injection), fluorescent beta-amyloid (intrahippocampal injection) and gold nanorods (intracortical injection) via MLV that significantly increased after the opening of BBB. Our studies also demonstrate that the BBB opening was associated with the improvement of neurocognitive status in mice with AD. Thus, we uncover therapeutic effects of BBB opening by loud music, such as non-invasive stimulation of lymphatic clearance of beta-amyloid in mice with AD, accompanied by improvement of their neurocognitive status. Our data are consistent with other results suggesting the therapeutic effect of BBB opening by focused ultrasound without drugs for patients with AD. This research was supported by a grant from RSF 18-75-10033

Keywords: Alzheimer's disease, beta-amyloid, blood-brain barrier, meningeal lymphatic vessels, repeated loud music

Procedia PDF Downloads 112
1499 The Detection of Implanted Radioactive Seeds on Ultrasound Images Using Convolution Neural Networks

Authors: Edward Holupka, John Rossman, Tye Morancy, Joseph Aronovitz, Irving Kaplan

Abstract:

A common modality for the treatment of early stage prostate cancer is the implantation of radioactive seeds directly into the prostate. The radioactive seeds are positioned inside the prostate to achieve optimal radiation dose coverage to the prostate. These radioactive seeds are positioned inside the prostate using Transrectal ultrasound imaging. Once all of the planned seeds have been implanted, two dimensional transaxial transrectal ultrasound images separated by 2 mm are obtained through out the prostate, beginning at the base of the prostate up to and including the apex. A common deep neural network, called DetectNet was trained to automatically determine the position of the implanted radioactive seeds within the prostate under ultrasound imaging. The results of the training using 950 training ultrasound images and 90 validation ultrasound images. The commonly used metrics for successful training were used to evaluate the efficacy and accuracy of the trained deep neural network and resulted in an loss_bbox (train) = 0.00, loss_coverage (train) = 1.89e-8, loss_bbox (validation) = 11.84, loss_coverage (validation) = 9.70, mAP (validation) = 66.87%, precision (validation) = 81.07%, and a recall (validation) = 82.29%, where train and validation refers to the training image set and validation refers to the validation training set. On the hardware platform used, the training expended 12.8 seconds per epoch. The network was trained for over 10,000 epochs. In addition, the seed locations as determined by the Deep Neural Network were compared to the seed locations as determined by a commercial software based on a one to three months after implant CT. The Deep Learning approach was within \strikeout off\uuline off\uwave off2.29\uuline default\uwave default mm of the seed locations determined by the commercial software. The Deep Learning approach to the determination of radioactive seed locations is robust, accurate, and fast and well within spatial agreement with the gold standard of CT determined seed coordinates.

Keywords: prostate, deep neural network, seed implant, ultrasound

Procedia PDF Downloads 170
1498 Ultrasound Assisted Cooling Crystallization of Lactose Monohydrate

Authors: Sanjaykumar R. Patel, Parth R. Kayastha

Abstract:

α-lactose monohydrate is widely used in the pharmaceutical industries as an inactive substance that acts as a vehicle or a medium for a drug or other active substance. It is a byproduct of dairy industries, and the recovery of lactose from whey not only boosts the improvement of the economics of whey utilization but also causes a reduction in pollution as lactose recovery can reduce the BOD of whey by more than 80%. In the present study, levels of process parameters were kept as initial lactose concentration (30-50% w/w), sonication amplitude (20-40%), sonication time (2-6 hours), and crystallization temperature (10-20 oC) for the recovery of lactose in ultrasound assisted cooling crystallization. In comparison with cooling crystallization, the use of ultrasound enhanced the lactose recovery by 39.17% (w/w). The parameters were optimized for the lactose recovery using Taguchi Method. The optimum conditions found were initial lactose concentration at level 3 (50% w/w), amplitude of sonication at level 2 (40%), the sonication time at level 3 (6 hours), and crystallization temperature at level 1 (10 °C). The maximum recovery was found to be 85.85% at the optimum conditions. Sonication time and the initial lactose concentration were found to be significant parameters for the lactose recovery.

Keywords: crystallization, lactose, Taguchi method, ultrasound

Procedia PDF Downloads 182
1497 Highly Skilled Migrants Trapped in the Brain Waste: The Eastern European Graduates in the Western European Underemployment

Authors: Katalin Bándy

Abstract:

The European emigration of highly educated immigrants draws attention to the problem of brain drain. Due to the Eastern European countries joining the EU and the opening of the Western European labour market the west-wards migration brisked up. By now another problem has been intensified correlated to migration: the migration of highly skilled workers related to brain waste tendencies. With some exceptions, educated immigrants from Eastern European countries are more likely to end up in unskilled jobs than residents. This paper is about to reveal the above-mentioned problems and this study is supported by the results of secondary pieces of research and the own survey made in the EU-15 among the Hungarian highly skilled (especially economics graduated) migrants, and it also examines the causes and in the focus there are the migrant motivations of the high-skilled young generation after the crisis.

Keywords: brain drain, brain waste, migration of highly-skilled, underemployment

Procedia PDF Downloads 317
1496 Endocardial Ultrasound Segmentation using Level Set method

Authors: Daoudi Abdelaziz, Mahmoudi Saïd, Chikh Mohamed Amine

Abstract:

This paper presents a fully automatic segmentation method of the left ventricle at End Systolic (ES) and End Diastolic (ED) in the ultrasound images by means of an implicit deformable model (level set) based on Geodesic Active Contour model. A pre-processing Gaussian smoothing stage is applied to the image, which is essential for a good segmentation. Before the segmentation phase, we locate automatically the area of the left ventricle by using a detection approach based on the Hough Transform method. Consequently, the result obtained is used to automate the initialization of the level set model. This initial curve (zero level set) deforms to search the Endocardial border in the image. On the other hand, quantitative evaluation was performed on a data set composed of 15 subjects with a comparison to ground truth (manual segmentation).

Keywords: level set method, transform Hough, Gaussian smoothing, left ventricle, ultrasound images.

Procedia PDF Downloads 439
1495 Autism Spectrum Disorder Classification Algorithm Using Multimodal Data Based on Graph Convolutional Network

Authors: Yuntao Liu, Lei Wang, Haoran Xia

Abstract:

Machine learning has shown extensive applications in the development of classification models for autism spectrum disorder (ASD) using neural image data. This paper proposes a fusion multi-modal classification network based on a graph neural network. First, the brain is segmented into 116 regions of interest using a medical segmentation template (AAL, Anatomical Automatic Labeling). The image features of sMRI and the signal features of fMRI are extracted, which build the node and edge embedding representations of the brain map. Then, we construct a dynamically updated brain map neural network and propose a method based on a dynamic brain map adjacency matrix update mechanism and learnable graph to further improve the accuracy of autism diagnosis and recognition results. Based on the Autism Brain Imaging Data Exchange I dataset(ABIDE I), we reached a prediction accuracy of 74% between ASD and TD subjects. Besides, to study the biomarkers that can help doctors analyze diseases and interpretability, we used the features by extracting the top five maximum and minimum ROI weights. This work provides a meaningful way for brain disorder identification.

Keywords: autism spectrum disorder, brain map, supervised machine learning, graph network, multimodal data, model interpretability

Procedia PDF Downloads 29
1494 Circle of Learning Using High-Fidelity Simulators Promoting a Better Understanding of Resident Physicians on Point-of-Care Ultrasound in Emergency Medicine

Authors: Takamitsu Kodama, Eiji Kawamoto

Abstract:

Introduction: Ultrasound in emergency room has advantages of safer, faster, repeatable and noninvasive. Especially focused Point-Of-Care Ultrasound (POCUS) is used daily for prompt and accurate diagnoses, for quickly identifying critical and life-threatening conditions. That is why ultrasound has demonstrated its usefulness in emergency medicine. The true value of ultrasound has been once again recognized in recent years. It is thought that all resident physicians working at emergency room should perform an ultrasound scan to interpret signs and symptoms of deteriorating patients in the emergency room. However, a practical education on ultrasound is still in development. To resolve this issue, we established a new educational program using high-fidelity simulators and evaluated the efficacy of this course. Methods: Educational program includes didactic lectures and skill stations in half-day course. Instructor gives a lecture on POCUS such as Rapid Ultrasound in Shock (RUSH) and/or Focused Assessment Transthoracic Echo (FATE) protocol at the beginning of the course. Then, attendees are provided for training of scanning with cooperation of normal simulated patients. In the end, attendees learn how to apply focused POCUS skills at clinical situation using high-fidelity simulators such as SonoSim® (SonoSim, Inc) and SimMan® 3G (Laerdal Medical). Evaluation was conducted through surveillance questionnaires to 19 attendees after two pilot courses. The questionnaires were focused on understanding course concept and satisfaction. Results: All attendees answered the questionnaires. With respect to the degree of understanding, 12 attendees (number of valid responses: 13) scored four or more points out of five points. High-fidelity simulators, especially SonoSim® was highly appreciated to enhance learning how to handle ultrasound at an actual practice site by 11 attendees (number of valid responses: 12). All attendees encouraged colleagues to take this course because the high level of satisfaction was achieved. Discussion: Newly introduced educational course using high-fidelity simulators realizes the circle of learning to deepen the understanding on focused POCUS by gradual stages. SonoSim® can faithfully reproduce scan images with pathologic findings of ultrasound and provide experimental learning for a growth number of beginners such as resident physicians. In addition, valuable education can be provided if it is used combined with SimMan® 3G. Conclusions: Newly introduced educational course using high-fidelity simulators is supposed to be effective and helps in providing better education compared with conventional courses for emergency physicians.

Keywords: point-of-care ultrasound, high-fidelity simulators, education, circle of learning

Procedia PDF Downloads 257
1493 MRI Compatible Fresnel Zone Plates made of Polylactic Acid

Authors: Daniel Tarrazó-Serrano, Sergio Pérez-López, Sergio Castiñeira-Ibáñez, Pilar Candelas, Constanza Rubio

Abstract:

Zone Plates (ZPs) are used in many areas of physics where planar fabrication is advantageous in comparison with conventional curved lenses. There are several types of ZPs, such as the well-known Fresnel ZPs or the more recent Fractal ZPs and Fibonacci ZPs. The material selection of the lens plays a very important role in the beam modulation control. This work presents a comparison between two Fresnel ZP made from different materials in the ultrasound domain: Polylactic Acid (PLA) and brass. PLA is the most common material used in commercial 3D-printers due to its high design flexibility and low cost. Numerical simulations based on Finite Element Method (FEM) and experimental results are shown, and they prove that the focusing capabilities of brass ZPs and PLA ZPs are similar. For this reason, PLA is proposed as a Magnetic Resonance Imaging (MRI) compatible material with great potential for therapeutic ultrasound focusing applications.

Keywords: FZP, PLA, focus, ultrasound, MRI

Procedia PDF Downloads 177
1492 African Personhood and the Regulation of Brain-Computer Interface (BCI) Technologies: A South African view

Authors: Meshandren Naidoo, Amy Gooden

Abstract:

Implantable brain-computer interface (BCI) technologies have developed to the point where brain-computer communication is possible. This has great potential in the medical field, as it allows persons who have lost capacities. However, ethicists and regulators call for a strict approach to these technologies due to the impact on personhood. This research demonstrates that the personhood debate is more nuanced and that where an African approach to personhood is used, it may produce results more favorable to the development and use of this technology.

Keywords: artificial intelligence, law, neuroscience, ethics

Procedia PDF Downloads 98
1491 Enabling Non-invasive Diagnosis of Thyroid Nodules with High Specificity and Sensitivity

Authors: Sai Maniveer Adapa, Sai Guptha Perla, Adithya Reddy P.

Abstract:

Thyroid nodules can often be diagnosed with ultrasound imaging, although differentiating between benign and malignant nodules can be challenging for medical professionals. This work suggests a novel approach to increase the precision of thyroid nodule identification by combining machine learning and deep learning. The new approach first extracts information from the ultrasound pictures using a deep learning method known as a convolutional autoencoder. A support vector machine, a type of machine learning model, is then trained using these features. With an accuracy of 92.52%, the support vector machine can differentiate between benign and malignant nodules. This innovative technique may decrease the need for pointless biopsies and increase the accuracy of thyroid nodule detection.

Keywords: thyroid tumor diagnosis, ultrasound images, deep learning, machine learning, convolutional auto-encoder, support vector machine

Procedia PDF Downloads 26
1490 Ultrasound Guided Treatment of Carpal Tunnel Syndrome

Authors: Kazem Shakouri, Alireza Pishgahi, Homayoun Sadeghi-bBazargani, Shahla Dareshiri

Abstract:

Introduction: Carpal Tunnel Syndrome has numerous nonsurgical treatments including splint, physical therapy and corticosteroid injections. Aim: The purpose of this study was to evaluate the effectiveness of an ultrasound guided treatment procedure, for individuals with severe carpal tunnel syndrome. Materials and Method: 20 patients with an electrodiagnostic evidence of severe carpal tunnel syndrome were treated by an office-based ultrasound guided procedure (combination of percutaneous needle release of carpal tunnel and corticosteroid injection). Electrodiagnostic (nerve conduction study), clinical (Boston Carpal Tunnel Questionnaire, grip strength) and ultrasonic (median nerve and carpal tunnel cross-sectional area) measurements were recorded at baseline and one month after intervention. Results: Our preliminary data analysis showed that in one month follow up, patients had a significantly smaller cross-sectional area of the median nerve compared to pretreatment values (mean difference 0.06; 95%CI: 0.02-0.1; p < 0.001). In addition, patients had significantly less functional impairment (mean difference 35; 95% CI:28.7-43.4 ; p < 0.001), and an improved hand grip strength in one month follow up (mean difference 5.4; 95%CI: 3.1-7.8; p < 0.001;). There were no significant complications. Conclusion: Patients with severe carpal tunnel syndrome, who are candidates for surgical intervention, can consider office-based ultrasound guided needle release of carpal tunnel as an alternative safe treatment.

Keywords: Carpal Tunnel Syndrome, needle release, pain, ultrasound

Procedia PDF Downloads 221