Search results for: medical imaging
4137 Airborne SAR Data Analysis for Impact of Doppler Centroid on Image Quality and Registration Accuracy
Authors: Chhabi Nigam, S. Ramakrishnan
Abstract:
This paper brings out the analysis of the airborne Synthetic Aperture Radar (SAR) data to study the impact of Doppler centroid on Image quality and geocoding accuracy from the perspective of Stripmap mode of data acquisition. Although in Stripmap mode of data acquisition radar beam points at 90 degrees broad side (side looking), shift in the Doppler centroid is invariable due to platform motion. In-accurate estimation of Doppler centroid leads to poor image quality and image miss-registration. The effect of Doppler centroid is analyzed in this paper using multiple sets of data collected from airborne platform. Occurrences of ghost (ambiguous) targets and their power levels have been analyzed that impacts appropriate choice of PRF. Effect of aircraft attitudes (roll, pitch and yaw) on the Doppler centroid is also analyzed with the collected data sets. Various stages of the RDA (Range Doppler Algorithm) algorithm used for image formation in Stripmap mode, range compression, Doppler centroid estimation, azimuth compression, range cell migration correction are analyzed to find the performance limits and the dependence of the imaging geometry on the final image. The ability of Doppler centroid estimation to enhance the imaging accuracy for registration are also illustrated in this paper. The paper also tries to bring out the processing of low squint SAR data, the challenges and the performance limits imposed by the imaging geometry and the platform dynamics on the final image quality metrics. Finally, the effect on various terrain types, including land, water and bright scatters is also presented.Keywords: ambiguous target, Doppler Centroid, image registration, Airborne SAR
Procedia PDF Downloads 2184136 Tongue Image Retrieval Based Using Machine Learning
Authors: Ahmad FAROOQ, Xinfeng Zhang, Fahad Sabah, Raheem Sarwar
Abstract:
In Traditional Chinese Medicine, tongue diagnosis is a vital inspection tool (TCM). In this study, we explore the potential of machine learning in tongue diagnosis. It begins with the cataloguing of the various classifications and characteristics of the human tongue. We infer 24 kinds of tongues from the material and coating of the tongue, and we identify 21 attributes of the tongue. The next step is to apply machine learning methods to the tongue dataset. We use the Weka machine learning platform to conduct the experiment for performance analysis. The 457 instances of the tongue dataset are used to test the performance of five different machine learning methods, including SVM, Random Forests, Decision Trees, and Naive Bayes. Based on accuracy and Area under the ROC Curve, the Support Vector Machine algorithm was shown to be the most effective for tongue diagnosis (AUC).Keywords: medical imaging, image retrieval, machine learning, tongue
Procedia PDF Downloads 824135 Producer’s Liability for Defective Medical Devices in Light of Council Directive 85/374/EEC
Authors: Vera Lúcia Raposo
Abstract:
Medical devices are products used for medical purposes and aimed to operate in the human body, sometimes even inside the human body. Therefore, they can become particularly risky products, and some of the injuries caused by medical devices can have serious effects on the person’s health or body, even leading to death. Because they fit in the category of 'products' as described in Article 2 of Council Directive 85/374/EEC of 25 July 1985, concerning liability for defective products, the liability of the manufacturer of medical devices follows the rules of strict liability as long as one of the defects covered by the directive is at stake. The directive is not concerned with the product’s efficiency, but instead with the product’s safety, although in what regards medical devices (the same being valid for drugs) the two concepts frequently go together, and a lack of efficiency can result in a lack of safety. In the particular case of medical devices, the most debatable defects are the ones related with erroneous or non-existing information and the so-called development defects. This paper analyses how directive 85/374/EEC applies to medical devices, which defects are covered by its regulation, and which criteria can be used to evaluate the product’s safety. Some issues are still to be clarified, even though the decisions from the European Court of Justice and from national courts are valuable tools to understand the scope of directive 85/374/EEC in what regards medical devices.Keywords: medical devices, producer’s liability, product safety, strict liability
Procedia PDF Downloads 3254134 Timeliness of Doppler Ultrasound for Suspected DVT in Compliance with National Guidelines: 4-Hours and 24-Hour Target
Authors: Sadaf Shaikh, Aishwariya Kapoor, Mustabshira Tahir, Zille Huma
Abstract:
In accordance with national criteria, the purpose of this audit is to assess how quickly Doppler ultrasound can diagnose suspected deep vein thrombosis (DVT). In particular, it emphasizes the 4- and 24-hour ultrasound imaging targets that are advised by medical guidelines. In order to avoid consequences like pulmonary embolism or post-thrombotic syndrome, which might result from postponed treatment, it is imperative that DVT be diagnosed promptly. Data on patients who presented with suspected DVT during a certain time period were extracted from electronic health records as part of the retrospective analysis. The study's main goal is to evaluate the hospital's compliance with the deadlines for Doppler ultrasounds performed after a clinical suspicion of DVT.Keywords: DVT, NICE compliance, Doppler ultrasound, d-dimer testing, vascular ultrasound, service delivery standards
Procedia PDF Downloads 124133 Probing Neuron Mechanics with a Micropipette Force Sensor
Authors: Madeleine Anthonisen, M. Hussain Sangji, G. Monserratt Lopez-Ayon, Margaret Magdesian, Peter Grutter
Abstract:
Advances in micromanipulation techniques and real-time particle tracking with nanometer resolution have enabled biological force measurements at scales relevant to neuron mechanics. An approach to precisely control and maneuver neurite-tethered polystyrene beads is presented. Analogous to an Atomic Force Microscope (AFM), this multi-purpose platform is a force sensor with imaging acquisition and manipulation capabilities. A mechanical probe composed of a micropipette with its tip fixed to a functionalized bead is used to incite the formation of a neurite in a sample of rat hippocampal neurons while simultaneously measuring the tension in said neurite as the sample is pulled away from the beaded tip. With optical imaging methods, a force resolution of 12 pN is achieved. Moreover, the advantages of this technique over alternatives such as AFM, namely ease of manipulation which ultimately allows higher throughput investigation of the mechanical properties of neurons, is demonstrated.Keywords: axonal growth, axonal guidance, force probe, pipette micromanipulation, neurite tension, neuron mechanics
Procedia PDF Downloads 3674132 Design and Manufacture Detection System for Patient's Unwanted Movements during Radiology and CT Scan
Authors: Anita Yaghobi, Homayoun Ebrahimian
Abstract:
One of the important tools that can help orthopedic doctors for diagnose diseases is imaging scan. Imaging techniques can help physicians in see different parts of the body, including the bones, muscles, tendons, nerves, and cartilage. During CT scan, a patient must be in the same position from the start to the end of radiation treatment. Patient movements are usually monitored by the technologists through the closed circuit television (CCTV) during scan. If the patient makes a small movement, it is difficult to be noticed by them. In the present work, a simple patient movement monitoring device is fabricated to monitor the patient movement. It uses an electronic sensing device. It continuously monitors the patient’s position while the CT scan is in process. The device has been retrospectively tested on 51 patients whose movement and distance were measured. The results show that 25 patients moved 1 cm to 2.5 cm from their initial position during the CT scan. Hence, the device can potentially be used to control and monitor patient movement during CT scan and Radiography. In addition, an audible alarm situated at the control panel of the control room is provided with this device to alert the technologists. It is an inexpensive, compact device which can be used in any CT scan machine.Keywords: CT scan, radiology, X Ray, unwanted movement
Procedia PDF Downloads 4614131 Proposition of an Ontology of Diseases and Their Signs from Medical Ontologies Integration
Authors: Adama Sow, Abdoulaye Guiss´e, Oumar Niang
Abstract:
To assist medical diagnosis, we propose a federation of several existing and open medical ontologies and terminologies. The goal is to merge the strengths of all these resources to provide clinicians the access to a variety of shared knowledges that can facilitate identification and association of human diseases and all of their available characteristic signs such as symptoms and clinical signs. This work results to an integration model loaded from target known ontologies of the bioportal platform such as DOID, MESH, and SNOMED for diseases selection, SYMP, and CSSO for all existing signs.Keywords: medical decision, medical ontologies, ontologies integration, linked data, knowledge engineering, e-health system
Procedia PDF Downloads 2004130 Segmentation of Liver Using Random Forest Classifier
Authors: Gajendra Kumar Mourya, Dinesh Bhatia, Akash Handique, Sunita Warjri, Syed Achaab Amir
Abstract:
Nowadays, Medical imaging has become an integral part of modern healthcare. Abdominal CT images are an invaluable mean for abdominal organ investigation and have been widely studied in the recent years. Diagnosis of liver pathologies is one of the major areas of current interests in the field of medical image processing and is still an open problem. To deeply study and diagnose the liver, segmentation of liver is done to identify which part of the liver is mostly affected. Manual segmentation of the liver in CT images is time-consuming and suffers from inter- and intra-observer differences. However, automatic or semi-automatic computer aided segmentation of the Liver is a challenging task due to inter-patient Liver shape and size variability. In this paper, we present a technique for automatic segmenting the liver from CT images using Random Forest Classifier. Random forests or random decision forests are an ensemble learning method for classification that operate by constructing a multitude of decision trees at training time and outputting the class that is the mode of the classes of the individual trees. After comparing with various other techniques, it was found that Random Forest Classifier provide a better segmentation results with respect to accuracy and speed. We have done the validation of our results using various techniques and it shows above 89% accuracy in all the cases.Keywords: CT images, image validation, random forest, segmentation
Procedia PDF Downloads 3134129 Fabrication of Poly(Ethylene Oxide)/Chitosan/Indocyanine Green Nanoprobe by Co-Axial Electrospinning Method for Early Detection
Authors: Zeynep R. Ege, Aydin Akan, Faik N. Oktar, Betul Karademir, Oguzhan Gunduz
Abstract:
Early detection of cancer could save human life and quality in insidious cases by advanced biomedical imaging techniques. Designing targeted detection system is necessary in order to protect of healthy cells. Electrospun nanofibers are efficient and targetable nanocarriers which have important properties such as nanometric diameter, mechanical properties, elasticity, porosity and surface area to volume ratio. In the present study, indocyanine green (ICG) organic dye was stabilized and encapsulated in polymer matrix which polyethylene oxide (PEO) and chitosan (CHI) multilayer nanofibers via co-axial electrospinning method at one step. The co-axial electrospun nanofibers were characterized as morphological (SEM), molecular (FT-IR), and entrapment efficiency of Indocyanine Green (ICG) (confocal imaging). Controlled release profile of PEO/CHI/ICG nanofiber was also evaluated up to 40 hours.Keywords: chitosan, coaxial electrospinning, controlled releasing, drug delivery, indocyanine green, polyethylene oxide
Procedia PDF Downloads 1704128 Application of Compressed Sensing and Different Sampling Trajectories for Data Reduction of Small Animal Magnetic Resonance Image
Authors: Matheus Madureira Matos, Alexandre Rodrigues Farias
Abstract:
Magnetic Resonance Imaging (MRI) is a vital imaging technique used in both clinical and pre-clinical areas to obtain detailed anatomical and functional information. However, MRI scans can be expensive, time-consuming, and often require the use of anesthetics to keep animals still during the imaging process. Anesthetics are commonly administered to animals undergoing MRI scans to ensure they remain still during the imaging process. However, prolonged or repeated exposure to anesthetics can have adverse effects on animals, including physiological alterations and potential toxicity. Minimizing the duration and frequency of anesthesia is, therefore, crucial for the well-being of research animals. In recent years, various sampling trajectories have been investigated to reduce the number of MRI measurements leading to shorter scanning time and minimizing the duration of animal exposure to the effects of anesthetics. Compressed sensing (CS) and sampling trajectories, such as cartesian, spiral, and radial, have emerged as powerful tools to reduce MRI data while preserving diagnostic quality. This work aims to apply CS and cartesian, spiral, and radial sampling trajectories for the reconstruction of MRI of the abdomen of mice sub-sampled at levels below that defined by the Nyquist theorem. The methodology of this work consists of using a fully sampled reference MRI of a female model C57B1/6 mouse acquired experimentally in a 4.7 Tesla MRI scanner for small animals using Spin Echo pulse sequences. The image is down-sampled by cartesian, radial, and spiral sampling paths and then reconstructed by CS. The quality of the reconstructed images is objectively assessed by three quality assessment techniques RMSE (Root mean square error), PSNR (Peak to Signal Noise Ratio), and SSIM (Structural similarity index measure). The utilization of optimized sampling trajectories and CS technique has demonstrated the potential for a significant reduction of up to 70% of image data acquisition. This result translates into shorter scan times, minimizing the duration and frequency of anesthesia administration and reducing the potential risks associated with it.Keywords: compressed sensing, magnetic resonance, sampling trajectories, small animals
Procedia PDF Downloads 754127 New Ethanol Method for Soft Tissue Imaging in Micro-CT
Authors: Matej Patzelt, Jan Dudak, Frantisek Krejci, Jan Zemlicka, Vladimir Musil, Jitka Riedlova, Viktor Sykora, Jana Mrzilkova, Petr Zach
Abstract:
Introduction: Micro-CT is well used for examination of bone structures and teeth. On the other hand visualization of the soft tissues is still limited. The goal of our study was to create a new fixation method for soft tissue imaging in micro-CT. Methodology: We used organs of 18 mice - heart, lungs, kidneys, liver and brain, which we fixated in ethanol after meticulous preparation. We fixated organs in different concentrations of ethanol and for different period of time. We used three types of ethanol concentration - 97%, 50% and ascending ethanol concentration (25%, 50%, 75%, 97% each for 12 hours). Fixated organs were scanned after 72 hours, 168 hours and 336 hours period of fixation. We scanned all specimens in micro-CT MARS (Medipix All Resolution System). Results: Ethanol method provided contrast enhancement in all studied organs in all used types of fixation. Fixation in 97% ethanol provided very fast fixation and the contrast among the tissues was visible already after 72 hours of fixation. Fixation for the period of 168 and 336 hours gave better details, especially in lung tissue, where alveoli were visualized. On the other hand, this type of fixation caused organs to petrify. Fixation in 50% ethanol provided best results in 336 hours fixation, details were visualized better than in 97% ethanol and samples were not as hard as in fixation in 97% ethanol. Best results were obtained in fixation in ascending ethanol concentration. All organs were visualized in great details, best-visualized organ was heart, where trabeculae and valves were visible. In this type of fixation, organs stayed soft for whole time. Conclusion: New ethanol method is a great option for soft tissue fixation as well as the method for enhancing contrast among tissues in organs. The best results were obtained with fixation of the organs in ascending ethanol concentration, the best visualized organ was the heart.Keywords: x-ray imaging, small animals, ethanol, ex-vivo
Procedia PDF Downloads 3214126 Use of Generative Adversarial Networks (GANs) in Neuroimaging and Clinical Neuroscience Applications
Authors: Niloufar Yadgari
Abstract:
GANs are a potent form of deep learning models that have found success in various fields. They are part of the larger group of generative techniques, which aim to produce authentic data using a probabilistic model that learns distributions from actual samples. In clinical settings, GANs have demonstrated improved abilities in capturing spatially intricate, nonlinear, and possibly subtle disease impacts in contrast to conventional generative techniques. This review critically evaluates the current research on how GANs are being used in imaging studies of different neurological conditions like Alzheimer's disease, brain tumors, aging of the brain, and multiple sclerosis. We offer a clear explanation of different GAN techniques for each use case in neuroimaging and delve into the key hurdles, unanswered queries, and potential advancements in utilizing GANs in this field. Our goal is to connect advanced deep learning techniques with neurology studies, showcasing how GANs can assist in clinical decision-making and enhance our comprehension of the structural and functional aspects of brain disorders.Keywords: GAN, pathology, generative adversarial network, neuro imaging
Procedia PDF Downloads 344125 Diffusion MRI: Clinical Application in Radiotherapy Planning of Intracranial Pathology
Authors: Pomozova Kseniia, Gorlachev Gennadiy, Chernyaev Aleksandr, Golanov Andrey
Abstract:
In clinical practice, and especially in stereotactic radiosurgery planning, the significance of diffusion-weighted imaging (DWI) is growing. This makes the existence of software capable of quickly processing and reliably visualizing diffusion data, as well as equipped with tools for their analysis in terms of different tasks. We are developing the «MRDiffusionImaging» software on the standard C++ language. The subject part has been moved to separate class libraries and can be used on various platforms. The user interface is Windows WPF (Windows Presentation Foundation), which is a technology for managing Windows applications with access to all components of the .NET 5 or .NET Framework platform ecosystem. One of the important features is the use of a declarative markup language, XAML (eXtensible Application Markup Language), with which you can conveniently create, initialize and set properties of objects with hierarchical relationships. Graphics are generated using the DirectX environment. The MRDiffusionImaging software package has been implemented for processing diffusion magnetic resonance imaging (dMRI), which allows loading and viewing images sorted by series. An algorithm for "masking" dMRI series based on T2-weighted images was developed using a deformable surface model to exclude tissues that are not related to the area of interest from the analysis. An algorithm of distortion correction using deformable image registration based on autocorrelation of local structure has been developed. Maximum voxel dimension was 1,03 ± 0,12 mm. In an elementary brain's volume, the diffusion tensor is geometrically interpreted using an ellipsoid, which is an isosurface of the probability density of a molecule's diffusion. For the first time, non-parametric intensity distributions, neighborhood correlations, and inhomogeneities are combined in one segmentation of white matter (WM), grey matter (GM), and cerebrospinal fluid (CSF) algorithm. A tool for calculating the coefficient of average diffusion and fractional anisotropy has been created, on the basis of which it is possible to build quantitative maps for solving various clinical problems. Functionality has been created that allows clustering and segmenting images to individualize the clinical volume of radiation treatment and further assess the response (Median Dice Score = 0.963 ± 0,137). White matter tracts of the brain were visualized using two algorithms: deterministic (fiber assignment by continuous tracking) and probabilistic using the Hough transform. The proposed algorithms test candidate curves in the voxel, assigning to each one a score computed from the diffusion data, and then selects the curves with the highest scores as the potential anatomical connections. White matter fibers were visualized using a Hough transform tractography algorithm. In the context of functional radiosurgery, it is possible to reduce the irradiation volume of the internal capsule receiving 12 Gy from 0,402 cc to 0,254 cc. The «MRDiffusionImaging» will improve the efficiency and accuracy of diagnostics and stereotactic radiotherapy of intracranial pathology. We develop software with integrated, intuitive support for processing, analysis, and inclusion in the process of radiotherapy planning and evaluating its results.Keywords: diffusion-weighted imaging, medical imaging, stereotactic radiosurgery, tractography
Procedia PDF Downloads 854124 Is the Addition of Computed Tomography with Angiography Superior to a Non-Contrast Neuroimaging Only Strategy for Patients with Suspected Stroke or Transient Ischemic Attack Presenting to the Emergency Department?
Authors: Alisha M. Ebrahim, Bijoy K. Menon, Eddy Lang, Shelagh B. Coutts, Katie Lin
Abstract:
Introduction: Frontline emergency physicians require clear and evidence-based approaches to guide neuroimaging investigations for patients presenting with suspected acute stroke or transient ischemic attack (TIA). Various forms of computed tomography (CT) are currently available for initial investigation, including non-contrast CT (NCCT), CT angiography head and neck (CTA), and CT perfusion (CTP). However, there is uncertainty around optimal imaging choice for cost-effectiveness, particularly for minor or resolved neurological symptoms. In addition to the cost of CTA and CTP testing, there is also a concern for increased incidental findings, which may contribute to the burden of overdiagnosis. Methods: In this cross-sectional observational study, analysis was conducted on 586 anonymized triage and diagnostic imaging (DI) reports for neuroimaging orders completed on patients presenting to adult emergency departments (EDs) with a suspected stroke or TIA from January-December 2019. The primary outcome of interest is the diagnostic yield of NCCT+CTA compared to NCCT alone for patients presenting to urban academic EDs with Canadian Emergency Department Information System (CEDIS) complaints of “symptoms of stroke” (specifically acute stroke and TIA indications). DI reports were coded into 4 pre-specified categories (endorsed by a panel of stroke experts): no abnormalities, clinically significant findings (requiring immediate or follow-up clinical action), incidental findings (not meeting prespecified criteria for clinical significance), and both significant and incidental findings. Standard descriptive statistics were performed. A two-sided p-value <0.05 was considered significant. Results: 75% of patients received NCCT+CTA imaging, 21% received NCCT alone, and 4% received NCCT+CTA+CTP. The diagnostic yield of NCCT+CTA imaging for prespecified clinically significant findings was 24%, compared to only 9% in those who received NCCT alone. The proportion of incidental findings was 30% in the NCCT only group and 32% in the NCCT+CTA group. CTP did not significantly increase the yield of significant or incidental findings. Conclusion: In this cohort of patients presenting with suspected stroke or TIA, an NCCT+CTA neuroimaging strategy had a higher diagnostic yield for clinically significant findings than NCCT alone without significantly increasing the number of incidental findings identified.Keywords: stroke, diagnostic yield, neuroimaging, emergency department, CT
Procedia PDF Downloads 1014123 Hypersensitivity Reactions Following Intravenous Administration of Contrast Medium
Authors: Joanna Cydejko, Paulina Mika
Abstract:
Hypersensitivity reactions are side effects of medications that resemble an allergic reaction. Anaphylaxis is a generalized, severe allergic reaction of the body caused by exposure to a specific agent at a dose tolerated by a healthy body. The most common causes of anaphylaxis are food (about 70%), Hymenoptera venoms (22%), and medications (7%), despite detailed diagnostics in 1% of people, the cause of the anaphylactic reaction was not indicated. Contrast media are anaphylactic agents of unknown mechanism. Hypersensitivity reactions can occur with both immunological and non-immunological mechanisms. Symptoms of anaphylaxis occur within a few seconds to several minutes after exposure to the allergen. Contrast agents are chemical compounds that make it possible to visualize or improve the visibility of anatomical structures. In the diagnosis of computed tomography, the preparations currently used are derivatives of the triiodide benzene ring. Pharmacokinetic and pharmacodynamic properties, i.e., their osmolality, viscosity, low chemotoxicity and high hydrophilicity, have an impact on better tolerance of the substance by the patient's body. In MRI diagnostics, macrocyclic gadolinium contrast agents are administered during examinations. The aim of this study is to present the results of the number and severity of anaphylactic reactions that occurred in patients in all age groups undergoing diagnostic imaging with intravenous administration of contrast agents. In non-ionic iodine CT and in macrocyclic gadolinium MRI. A retrospective assessment of the number of adverse reactions after contrast administration was carried out on the basis of data from the Department of Radiology of the University Clinical Center in Gdańsk, and it was assessed whether their different physicochemical properties had an impact on the incidence of acute complications. Adverse reactions are divided according to the severity of the patient's condition and the diagnostic method used in a given patient. Complications following the administration of a contrast medium in the form of acute anaphylaxis accounted for less than 0.5% of all diagnostic procedures performed with the use of a contrast agent. In the analysis period from January to December 2022, 34,053 CT scans and 15,279 MRI examinations with the use of contrast medium were performed. The total number of acute complications was 21, of which 17 were complications of iodine-based contrast agents and 5 of gadolinium preparations. The introduction of state-of-the-art contrast formulations was an important step toward improving the safety and tolerability of contrast agents used in imaging. Currently, contrast agents administered to patients are considered to be one of the best-tolerated preparations used in medicine. However, like any drug, they can be responsible for the occurrence of adverse reactions resulting from their toxic effects. The increase in the number of imaging tests performed with the use of contrast agents has a direct impact on the number of adverse events associated with their administration. However, despite the low risk of anaphylaxis, this risk should not be marginalized. The growing threat associated with the mass performance of radiological procedures with the use of contrast agents forces the knowledge of the rules of conduct in the event of symptoms of hypersensitivity to these preparations.Keywords: anaphylactic, contrast medium, diagnostic, medical imagine
Procedia PDF Downloads 634122 Self-Supervised Pretraining on Sequences of Functional Magnetic Resonance Imaging Data for Transfer Learning to Brain Decoding Tasks
Authors: Sean Paulsen, Michael Casey
Abstract:
In this work we present a self-supervised pretraining framework for transformers on functional Magnetic Resonance Imaging (fMRI) data. First, we pretrain our architecture on two self-supervised tasks simultaneously to teach the model a general understanding of the temporal and spatial dynamics of human auditory cortex during music listening. Our pretraining results are the first to suggest a synergistic effect of multitask training on fMRI data. Second, we finetune the pretrained models and train additional fresh models on a supervised fMRI classification task. We observe significantly improved accuracy on held-out runs with the finetuned models, which demonstrates the ability of our pretraining tasks to facilitate transfer learning. This work contributes to the growing body of literature on transformer architectures for pretraining and transfer learning with fMRI data, and serves as a proof of concept for our pretraining tasks and multitask pretraining on fMRI data.Keywords: transfer learning, fMRI, self-supervised, brain decoding, transformer, multitask training
Procedia PDF Downloads 904121 Importance of Knowledge in the Interdisciplinary Production Processes of Innovative Medical Tools
Authors: Katarzyna Mleczko
Abstract:
Processes of production of innovative medical tools have interdisciplinary character. They consist of direct and indirect close cooperation of specialists of different scientific branches. The Knowledge they have seems to be important for undertaken design, construction and manufacturing processes. The Knowledge exchange between participants of these processes is therefore crucial for the final result, which are innovative medical products. The paper draws attention to the necessity of feedback from the end user to the designer / manufacturer of medical tools which will allow for more accurate understanding of user needs. The study describes prerequisites of production processes of innovative medical (surgical) tools including participants and category of knowledge resources occurring in these processes. They are the result of research in selected Polish organizations involved in the production of medical instruments and are the basis for further work on the development of knowledge sharing model in interdisciplinary teams geographically dispersed.Keywords: interdisciplinary production processes, knowledge exchange, knowledge sharing, medical tools
Procedia PDF Downloads 4424120 Economic Policy of Tourism and the Development Tendencies of Medical Wellness Resorts in Georgia
Authors: G. Erkomaishvili, E. Kharaishvili, M. Chavleishvili, N. Sagareishvili
Abstract:
This paper discusses the current condition of tourism and its economic policy in Georgia. It analyzes and studies wellness tourism, as one of the directions of tourism; the newest niche in the wellness industry – triggering wellness resorts with medical ideology. The paper discusses the development tendencies of medical wellness resorts in Georgia and its main economic preferences. The main finding of the research is that Georgia is a unique place in the world according to the variety of medical recourses. This makes the opportunity to create and successfully operate medical wellness resorts, as well as develop it as a brand for Georgia in the world. The research represents the development strategies of tourism and its medical wellness resorts in Georgia, and offers recommendations based on the relevant conclusions.Keywords: tourism, economic policy of tourism, wellness industry, medical wellness resorts
Procedia PDF Downloads 3404119 Improving Research Collaborations in Medical Device Development in Korea from an SMEs’ Perspective
Authors: Yoon Chung Kim
Abstract:
In this coming aging society, medical device industry is expected to become one of the major industries. Since developing medical devices usually requires technology convergence, research collaboration is important, especially for some small and medium enterprises (SMEs) that do not have enough R&D resources in each related field. Collaboration in medical device development has some unique properties. Since it requires convergence technology, collaboration with different fields, and different types of people are often required. Since it requires clinical test, the development process usually takes longer and collaboration with hospitals is also required. However, despite these importance and uniqueness, collaboration in medical device development has not yet been widely studied. Thus, our research focuses on investigating collaborations in medical device development. For our research, we conducted surveys and interviews, especially with SMEs’ perspective in Korea. The result and discussion will be presented with a major impact factors for collaboration result, as well as future strategies that will improve and strengthen collaboration process in medical devices.Keywords: medical device, SME, research collaboration, development, clinical
Procedia PDF Downloads 3304118 Application of Zeolite Nanoparticles in Biomedical Optics
Authors: Vladimir Hovhannisyan, Chen Yuan Dong
Abstract:
Recently nanoparticles (NPs) have been introduced in biomedicine as effective agents for cancer-targeted drug delivery and noninvasive tissue imaging. The most important requirements to these agents are their non-toxicity, biocompatibility and stability. In view of these criteria, the zeolite (ZL) nanoparticles (NPs) may be considered as perfect candidates for biomedical applications. ZLs are crystalline aluminosilicates consisting of oxygen-sharing SiO4 and AlO4 tetrahedral groups united by common vertices in three-dimensional framework and containing pores with diameters from 0.3 to 1.2 nm. Generally, the behavior and physical properties of ZLs are studied by SEM, X-ray spectroscopy, and AFM, whereas optical spectroscopic and microscopic approaches are not effective enough, because of strong scattering in common ZL bulk materials and powders. The light scattering can be reduced by using of ZL NPs. ZL NPs have large external surface area, high dispersibility in both aqueous and organic solutions, high photo- and thermal stability, and exceptional ability to adsorb various molecules and atoms in their nanopores. In this report, using multiphoton microscopy and nonlinear spectroscopy, we investigate nonlinear optical properties of clinoptilolite type of ZL micro- and nanoparticles with average diameters of 2200 nm and 240 nm, correspondingly. Multiphoton imaging is achieved using a laser scanning microscope system (LSM 510 META, Zeiss, Germany) coupled to a femtosecond titanium:sapphire laser (repetition rate- 80 MHz, pulse duration-120 fs, radiation wavelength- 720-820 nm) (Tsunami, Spectra-Physics, CA). Two Zeiss, Plan-Neofluar objectives (air immersion 20×∕NA 0.5 and water immersion 40×∕NA 1.2) are used for imaging. For the detection of the nonlinear response, we use two detection channels with 380-400 nm and 435-700 nm spectral bandwidths. We demonstrate that ZL micro- and nanoparticles can produce nonlinear optical response under the near-infrared femtosecond laser excitation. The interaction of hypericine, chlorin e6 and other dyes with ZL NPs and their photodynamic activity is investigated. Particularly, multiphoton imaging shows that individual ZL NPs particles adsorb Zn-tetraporphyrin molecules, but do not adsorb fluorescein molecules. In addition, nonlinear spectral properties of ZL NPs in native biotissues are studied. Nonlinear microscopy and spectroscopy may open new perspectives in the research and application of ZL NP in biomedicine, and the results may help to introduce novel approaches into the clinical environment.Keywords: multiphoton microscopy, nanoparticles, nonlinear optics, zeolite
Procedia PDF Downloads 4174117 The Importance of Artificial Intelligence in Various Healthcare Applications
Authors: Joshna Rani S., Ahmadi Banu
Abstract:
Artificial Intelligence (AI) has a significant task to carry out in the medical care contributions of things to come. As AI, it is the essential capacity behind the advancement of accuracy medication, generally consented to be a painfully required development in care. Albeit early endeavors at giving analysis and treatment proposals have demonstrated testing, we anticipate that AI will at last dominate that area too. Given the quick propels in AI for imaging examination, it appears to be likely that most radiology, what's more, pathology pictures will be inspected eventually by a machine. Discourse and text acknowledgment are now utilized for assignments like patient correspondence and catch of clinical notes, and their utilization will increment. The best test to AI in these medical services areas isn't regardless of whether the innovations will be sufficiently skilled to be valuable, but instead guaranteeing their appropriation in day by day clinical practice. For far reaching selection to happen, AI frameworks should be affirmed by controllers, coordinated with EHR frameworks, normalized to an adequate degree that comparative items work likewise, instructed to clinicians, paid for by open or private payer associations, and refreshed over the long haul in the field. These difficulties will, at last, be survived, yet they will take any longer to do as such than it will take for the actual innovations to develop. Therefore, we hope to see restricted utilization of AI in clinical practice inside 5 years and more broad use inside 10 years. It likewise appears to be progressively evident that AI frameworks won't supplant human clinicians for a huge scope, yet rather will increase their endeavors to really focus on patients. Over the long haul, human clinicians may advance toward errands and work plans that draw on remarkably human abilities like sympathy, influence, and higher perspective mix. Maybe the lone medical services suppliers who will chance their professions over the long run might be the individuals who will not work close by AIKeywords: artificial intellogence, health care, breast cancer, AI applications
Procedia PDF Downloads 1824116 Management of Medical Equipment Maintenance
Authors: Gholamreza Madad
Abstract:
The role of medical equipment in modern advanced hospitals is irrefutable. Despite limited financial resources, developing countries have taken an uncontrollable manner to the purchase of complex and expensive equipment, although they have not taken good maintenance to keep these huge capitals. In our country, limited studies have indicated that the irregularities exist in the management of medical equipment maintenance. Research method: The research was done as a cross-sectional one, and in this study, a questionnaire was used to collect data in 10 hospitals. After distributing and collecting questionnaires in person, the collected data were analyzed using descriptive statistics and SPSS software. Research findings: According to the obtained results from the four dimensions of the management of medical equipment maintenance, only (maintenance planning) was in a moderate position and other components with a score of less than 50% were at a low level. There was a direct relationship between the total score of maintenance management and guidance points and coordination of medical equipment maintenance, and as well as the age of hospital managers. Discussion and conclusion: In sum, we can say that problems such as lack of skilled staff in medical engineering departments of hospitals, lack of funds and unaware of the authorities of medical engineering units to their duties have caused that the maintenance situation of medical equipment maintenance is in poor condition (near average). The low inexperience of the authorities of the unit has also contributed to this problem.Keywords: equipment, maintenance, medical equipment, hospitals
Procedia PDF Downloads 1634115 Medical Social Work: Connotation, Prospects, and Challenges in Pakistan
Authors: Syeda Mahnaz Hassan
Abstract:
Social work as a specialized field, grounded in scientific knowledge and skills, is more inclined towards problem-solving process rather than charity focused approach. Medical social work, as a primary method, deals with the bio-psychosocial-spiritual elements of an individual with a problem and assesses the pliability and strength of the patients, social support systems, and their families, to assist the patients to resolve their problems independently. The medical social worker, also known as case-worker or care-worker, has to play a substantial role in the rehabilitation and retrieval of an affected person. This paper examines the roles played and responsibilities discharged by the Medical Social Workers internationally and specifically concerning Pakistan. The capacity constraints and challenges confronted by Medical Social Workers in hospitals have also been highlighted, and some policy implications have been suggested to enhance the capabilities of Medical Social Workers for serving the patients in a befitting manner.Keywords: medical social work, Pakistan, patients, rehabilitation
Procedia PDF Downloads 3634114 Single Centre Retrospective Analysis of MR Imaging in Placenta Accreta Spectrum Disorder with Histopathological Correlation
Authors: Frank Dorrian, Aniket Adhikari
Abstract:
The placenta accreta spectrum (PAS), which includes placenta accreta, increta, and percreta, is characterized by the abnormal implantation of placental chorionic villi beyond the decidua basalis. Key risk factors include placenta previa, prior cesarean sections, advanced maternal age, uterine surgeries, multiparity, pelvic radiation, and in vitro fertilization (IVF). The incidence of PAS has increased tenfold over the past 50 years, largely due to rising cesarean rates. PAS is associated with significant peripartum and postpartum hemorrhage. Magnetic resonance imaging (MRI) and ultrasound assist in the evaluation of PAS, enabling a multidisciplinary approach to mitigate morbidity and mortality. This study retrospectively analyzed PAS cases at Royal Prince Alfred Hospital, Sydney, Australia. Using the SAR-ESUR joint consensus statement, seven imaging signs were reassessed for their sensitivity and specificity in predicting PAS, with histopathological correlation. The standardized MRI protocols for PAS at the institution were also reviewed. Data were collected from the picture archiving and communication system (PACS) records from 2010 to July 2024, focusing on cases where MR imaging and confirmed histopathology or operative notes were available. This single-center, observational study provides insights into the reliability of MRI for PAS detection and the optimization of imaging protocols for accurate diagnosis. The findings demonstrate that intraplacental dark bands serve as highly sensitive markers for diagnosing PAS, achieving sensitivities of 88.9%, 85.7%, and 100% for placenta accreta, increta, and percreta, respectively, with a combined specificity of 42.9%. Sensitivity for abnormal vascularization was lower (33.3%, 28.6%, and 50%), with a specificity of 57.1%. The placenta bulge exhibited sensitivities of 55.5%, 57.1%, and 100%, with a specificity of 57.1%. Loss of the T2 hypointense interface had sensitivities of 66.6%, 85.7%, and 100%, with 42.9% specificity. Myometrial thinning showed high sensitivity across PAS conditions (88.9%, 71.4%, and 100%) and a specificity of 57.1%. Bladder wall thinning was sensitive only for placenta percreta (50%) but had a specificity of 100%. Focal exophytic mass displayed variable sensitivity (22.9%, 42.9%, and 100%) with a specificity of 85.7%. These results highlight the diagnostic variability among markers, with intraplacental dark bands and myometrial thinning being useful in detecting abnormal placentation, though they lack high specificity. The literature and the results of our study highlight that while no single feature can definitively diagnose PAS, the presence of multiple features -especially when combined with elevated clinical risk- significantly increases the likelihood of an underlying PAS. A thorough understanding of the range of MRI findings associated with PAS, along with awareness of the clinical significance of each sign, helps the radiologist more accurately diagnose the condition and assist in surgical planning, ultimately improving patient care.Keywords: placenta, accreta, spectrum, MRI
Procedia PDF Downloads 204113 A Four Free Element Radiofrequency Coil with High B₁ Homogeneity for Magnetic Resonance Imaging
Authors: Khalid Al-Snaie
Abstract:
In this paper, the design and the testing of a symmetrical radiofrequency prototype coil with high B₁ magnetic field homogeneity are presented. The developed coil comprises four tuned coaxial circular loops that can produce a relatively homogeneous radiofrequency field. In comparison with a standard Helmholtz pair that provides 2nd-order homogeneity, it aims to provide fourth-order homogeneity of the B₁ field while preserving the simplicity of implementation. Electrical modeling of the probe, including all couplings, is used to ensure these requirements. Results of comparison tests, in free space and in a spectro-imager, between a standard Helmholtz pair and the presented prototype coil are introduced. In terms of field homogeneity, an improvement of 30% is observed. Moreover, the proposed prototype coil possesses a better quality factor (+25% on average) and a noticeable improvement in sensitivity (+20%). Overall, this work, which includes both theoretical and experimental aspects, aims to contribute to the study and understanding of four-element radio frequency (RF) systems derived from Helmholtz coils for Magnetic Resonance ImagingKeywords: B₁ homogeneity, MRI, NMR, radiofrequency, RF coil, free element systems
Procedia PDF Downloads 914112 Infertility Awareness: Knowledge and Attitude of Medical & Non-Medical Moroccan Young People
Authors: Sana El Adlani, Yassir Ait Ben Kaddour, Abdelhafid Benksim, Abderraouf Soummani, Mohamed Cherkaoui
Abstract:
Background: Infertility in all countries of the word is on an increase, it’s why the World Health Organization included an investigation into young people's fertility. In this sense, it’s important to increase efforts to improve the knowledge about fertility for the young population. The aim of this study is to describe the difference between knowledge and attitude of medical and non-medical Moroccan young people. Materials and Methods: 100 medical Moroccan students (group 1) participated in the study, between 18 and 30 years, by a simple random sampling method, during 2020 and using a previously validated questionnaire. The answers were confronted to the result of our same study among 355 non-medical Moroccan young people (group 2) in 2019. Statistical analyses were performed using Statistical Package for the Social Sciences (version 10). Result: Medical students had a significantly higher level of knowledge about infertility than non-medical young people. However, both groups were aware of the impact of lifestyle on infertility. The knowledge state of the first group about infertility management was higher than the second group. Moreover, all non-medical Moroccan young people believed that it is easier to conceive if the couples had already their first baby, whereas, among medical students, only 53% had confirmed this belief. The results showed that 65% of medical students had proposed to try fertility treatments more than one time if treatment fails. Besides, the first advice of the second group was polygamy and adoption. Conclusion: Following the result of our study, the investigation of young people is the measure to optimize reproductive health. So, it’s crucial that the government increase efforts to improve the knowledge about infertility not only for medical universities but for all scholar programs.Keywords: attitude, infertility, knowledge, medical, non-medical, young people
Procedia PDF Downloads 2304111 U-Net Based Multi-Output Network for Lung Disease Segmentation and Classification Using Chest X-Ray Dataset
Authors: Jaiden X. Schraut
Abstract:
Medical Imaging Segmentation of Chest X-rays is used for the purpose of identification and differentiation of lung cancer, pneumonia, COVID-19, and similar respiratory diseases. Widespread application of computer-supported perception methods into the diagnostic pipeline has been demonstrated to increase prognostic accuracy and aid doctors in efficiently treating patients. Modern models attempt the task of segmentation and classification separately and improve diagnostic efficiency; however, to further enhance this process, this paper proposes a multi-output network that follows a U-Net architecture for image segmentation output and features an additional CNN module for auxiliary classification output. The proposed model achieves a final Jaccard Index of .9634 for image segmentation and a final accuracy of .9600 for classification on the COVID-19 radiography database.Keywords: chest X-ray, deep learning, image segmentation, image classification
Procedia PDF Downloads 1454110 An Audit on the Quality of Pre-Operative Intra-Oral Digital Radiographs Taken for Dental Extractions in a General Practice Setting
Authors: Gabrielle O'Donoghue
Abstract:
Background: Pre-operative radiographs facilitate assessment and treatment planning in minor oral surgery. Quality assurance for dental radiography advocates the As Low As Reasonably Achievable (ALARA) principle in collecting accurate diagnostic information. Aims: To audit the quality of digital intraoral periapicals (IOPAs) taken prior to dental extractions in a metropolitan general dental practice setting. Standards: The National Radiological Protection Board (NRPB) guidance outlines three grades of radiograph quality: excellent (Grade 1 > 70% of total exposures), diagnostically acceptable (Grade 2 <20%), and unacceptable (Grade 3 <10%). Methodology: A study of pre-operative radiographs taken prior to dental extractions across 12 private general dental practices in a large metropolitan area by 44 practitioners. A total of 725 extractions were assessed, allowing 258 IOPAs to be reviewed in one audit cycle. Results: First cycle: Of 258 IOPAs: 223(86.4%) scored Grade 1, 27(10.5%) Grade 2, and 8(3.1%) Grade 3. The standard was met. 35 dental extractions were performed without an available pre-operative radiograph. Action Plan & Recommendations: Results were distributed to all staff and a continuous professional development evening organized to outline recommendations to improve image quality. A second audit cycle is proposed at a six-month interval to review the recommendations and appraise results. Conclusion: The overall standard of radiographs met the published guidelines. A significant improvement in the number of procedures undertaken without pre-operative imaging is expected at a six-month interval period. An investigation into undiagnostic imaging and associated adverse patient outcomes is being considered. Maintenance of the standards achieved is predicted in the second audit cycle to ensure consistent high quality imaging.Keywords: audit, oral radiology, oral surgery, periapical radiographs, quality assurance
Procedia PDF Downloads 1664109 Thermal Imaging of Aircraft Piston Engine in Laboratory Conditions
Authors: Lukasz Grabowski, Marcin Szlachetka, Tytus Tulwin
Abstract:
The main task of the engine cooling system is to maintain its average operating temperatures within strictly defined limits. Too high or too low average temperatures result in accelerated wear or even damage to the engine or its individual components. In order to avoid local overheating or significant temperature gradients, leading to high stresses in the component, the aim is to ensure an even flow of air. In the case of analyses related to heat exchange, one of the main problems is the comparison of temperature fields because standard measuring instruments such as thermocouples or thermistors only provide information about the course of temperature at a given point. Thermal imaging tests can be helpful in this case. With appropriate camera settings and taking into account environmental conditions, we are able to obtain accurate temperature fields in the form of thermograms. Emission of heat from the engine to the engine compartment is an important issue when designing a cooling system. Also, in the case of liquid cooling, the main sources of heat in the form of emissions from the engine block, cylinders, etc. should be identified. It is important to redesign the engine compartment ventilation system. Ensuring proper cooling of aircraft reciprocating engine is difficult not only because of variable operating range but mainly because of different cooling conditions related to the change of speed or altitude of flight. Engine temperature also has a direct and significant impact on the properties of engine oil, which under the influence of this parameter changes, in particular, its viscosity. Too low or too high, its value can be a result of fast wear of engine parts. One of the ways to determine the temperatures occurring on individual parts of the engine is the use of thermal imaging measurements. The article presents the results of preliminary thermal imaging tests of aircraft piston diesel engine with a maximum power of about 100 HP. In order to perform the heat emission tests of the tested engine, the ThermaCAM S65 thermovision monitoring system from FLIR (Forward-Looking Infrared) together with the ThermaCAM Researcher Professional software was used. The measurements were carried out after the engine warm up. The engine speed was 5300 rpm The measurements were taken for the following environmental parameters: air temperature: 17 °C, ambient pressure: 1004 hPa, relative humidity: 38%. The temperatures distribution on the engine cylinder and on the exhaust manifold were analysed. Thermal imaging tests made it possible to relate the results of simulation tests to the real object by measuring the rib temperature of the cylinders. The results obtained are necessary to develop a CFD (Computational Fluid Dynamics) model of heat emission from the engine bay. The project/research was financed in the framework of the project Lublin University of Technology-Regional Excellence Initiative, funded by the Polish Ministry of Science and Higher Education (contract no. 030/RID/2018/19).Keywords: aircraft, piston engine, heat, emission
Procedia PDF Downloads 1194108 Genetically Encoded Tool with Time-Resolved Fluorescence Readout for the Calcium Concentration Measurement
Authors: Tatiana R. Simonyan, Elena A. Protasova, Anastasia V. Mamontova, Eugene G. Maksimov, Konstantin A. Lukyanov, Alexey M. Bogdanov
Abstract:
Here, we describe two variants of the calcium indicators based on the GCaMP sensitive core and BrUSLEE fluorescent protein (GCaMP-BrUSLEE and GCaMP-BrUSLEE-145). In contrast to the conventional GCaMP6-family indicators, these fluorophores are characterized by the well-marked responsiveness of their fluorescence decay kinetics to external calcium concentration both in vitro and in cellulo. Specifically, we show that the purified GCaMP-BrUSLEE and GCaMP-BrUSLEE-145 exhibit three-component fluorescence decay kinetics, with the amplitude-normalized lifetime component (t3*A3) of GCaMP-BrUSLEE-145 changing four-fold (500-2000 a.u.) in response to a Ca²⁺ concentration shift in the range of 0—350 nM. Time-resolved fluorescence microscopy of live cells displays the two-fold change of the GCaMP-BrUSLEE-145 mean lifetime upon histamine-stimulated calcium release. The aforementioned Ca²⁺-dependence calls considering the GCaMP-BrUSLEE-145 as a prospective Ca²⁺-indicator with the signal read-out in the time domain.Keywords: calcium imaging, fluorescence lifetime imaging microscopy, fluorescent proteins, genetically encoded indicators
Procedia PDF Downloads 158