Search results for: sway mode
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 1992

Search results for: sway mode

1992 Dynamic Test for Stability of Columns in Sway Mode

Authors: Elia Efraim, Boris Blostotsky

Abstract:

Testing of columns in sway mode is performed in order to determine the maximal allowable load limited by plastic deformations or their end connections and a critical load limited by columns stability. Motivation to determine accurate value of critical force is caused by its using as follow: - critical load is maximal allowable load for given column configuration and can be used as criterion of perfection; - it is used in calculation prescribed by standards for design of structural elements under combined action of compression and bending; - it is used for verification of theoretical analysis of stability at various end conditions of columns. In the present work a new non-destructive method for determination of columns critical buckling load in sway mode is proposed. The method allows performing measurements during the tests under loads that exceeds the columns critical load without losing its stability. The possibility of such loading is achieved by structure of the loading system. The system is performed as frame with rigid girder, one of the columns is the tested column and the other is additional two-hinged strut. Loading of the frame is carried out by the flexible traction element attached to the girder. The load applied on the tested column can achieve values that exceed the critical load by choice of parameters of the traction element and the additional strut. The system lateral stiffness and the column critical load are obtained by the dynamic method. The experiment planning and the comparison between the experimental and theoretical values were performed based on the developed dependency of lateral stiffness of the system on vertical load, taking into account semi-rigid connections of the column's ends. The agreement between the obtained results was established. The method can be used for testing of real full-size columns in industrial conditions.

Keywords: buckling, columns, dynamic method, end-fixity factor, sway mode

Procedia PDF Downloads 326
1991 Dynamic Test for Sway-Mode Buckling of Columns

Authors: Boris Blostotsky, Elia Efraim

Abstract:

Testing of columns in sway mode is performed in order to determine the maximal allowable load limited by plastic deformations or their end connections and a critical load limited by columns stability. Motivation to determine accurate value of critical force is caused by its using as follow: - critical load is maximal allowable load for given column configuration and can be used as criterion of perfection; - it is used in calculation prescribed by standards for design of structural elements under combined action of compression and bending; - it is used for verification of theoretical analysis of stability at various end conditions of columns. In the present work a new non-destructive method for determination of columns critical buckling load in sway mode is proposed. The method allows performing measurements during the tests under loads that exceeds the columns critical load without losing its stability. The possibility of such loading is achieved by structure of the loading system. The system is performed as frame with rigid girder, one of the columns is the tested column and the other is additional two-hinged strut. Loading of the frame is carried out by the flexible traction element attached to the girder. The load applied on the tested column can achieve a values that exceed the critical load by choice of parameters of the traction element and the additional strut. The system lateral stiffness and the column critical load are obtained by the dynamic method. The experiment planning and the comparison between the experimental and theoretical values were performed based on the developed dependency of lateral stiffness of the system on vertical load, taking into account a semi-rigid connections of the column's ends. The agreement between the obtained results was established. The method can be used for testing of real full-size columns in industrial conditions.

Keywords: buckling, columns, dynamic method, semi-rigid connections, sway mode

Procedia PDF Downloads 288
1990 An Improved Amplified Sway Method for Semi-Rigidly Jointed Sway Frames

Authors: Abdul Hakim Chikho

Abstract:

A simple method of calculating satisfactory of the effect of instability on the distribution of in-plane bending moments in unbraced semi-rigidly multistory steel framed structures is presented in this paper. This method, which is a modified form of the current amplified sway method of BS5950: part1:2000, uses an approximate load factor at elastic instability in each storey of a frame which in turn dependent up on the axial loads acting in the columns. The calculated factors are then used to represent the geometrical deformations due to the presence of axial loads, acting in that storey. Only a first order elastic analysis is required to accomplish the calculation. Comparison of the prediction of the proposed method and the current BS5950 amplified sway method with an accurate second order elastic computation shows that the proposed method leads to predictions which are markedly more accurate than the current approach of BS5950.

Keywords: improved amplified sway method, steel frames, semi-rigid connections, secondary effects

Procedia PDF Downloads 57
1989 The Effect of Peripheral Fatigue and Visual Feedback on Postural Control and Strength in Obese People

Authors: Elham Azimzadeh, Saeedeh Sepehri, Hamidollah Hassanlouei

Abstract:

Obesity is associated with postural instability, might influence the quality of daily life, and could be considered a potential factor for falling in obese people. The fat body mass especially in the abdominal area may increase body sway. Furthermore, loss of visual feedback may induce a larger postural sway in obese people. Moreover, Muscle fatigue may impair the work capacity of the skeletal muscle and may alter joint proprioception. So, the purpose of this study was to investigate the effect of physical fatigue and visual feedback on body sway and strength of lower extremities in obese people. 12 obese (4 female, 8 male; BMI >30 kg/m2), and 12 normal weight (4 female, 8 male; BMI: 20-25 kg/m2) subjects aged 37- 47 years participated in this study. The postural stability test on the Biodex balance system was used to characterize postural control along the anterior-posterior (AP) and mediolateral (ML) directions in eyes open and eyes closed conditions and maximal voluntary contraction (MVC) of knee extensors and flexors were measured before and after the high-intensity exhausting exercise protocol on the ergometer bike to confirm the presence of fatigue. Results indicated that the obese group demonstrated significantly greater body sway, in all indices (ML, AP, overall) compared with the normal weight group (eyes open). However, when visual feedback was eliminated, fatigue impaired the balance in the overall and AP indicators in both groups; ML sway was higher only in the obese group after exerting the fatigue in the eyes closed condition. Also, maximal voluntary contraction of knee extensors was impaired in the fatigued normal group but, there was no significant impairment in knee flexors MVC in both group. According to the findings, peripheral fatigue was associated with altered postural control in upright standing when eyes were closed, and that mechanoreceptors of the feet may be less able to estimate the position of the body COM over the base of support in the loss of visual feedback. This suggests that the overall capability of the postural control system during upright standing especially in the ML direction could be lower due to fatigue in obese individuals and could be a predictor of future falls.

Keywords: maximal voluntary contraction, obesity, peripheral fatigue, postural control, visual feedback

Procedia PDF Downloads 59
1988 Effects of Wearable Garments on Postural Regulation in Community-Dwelling Elderly Adults

Authors: Mei Teng Woo, Keith Davids, Jarmo Liukkonen, Jia Yi Chow, Timo Jaakkola

Abstract:

Wearable garments such as tapes, compression garments, and braces could improve proprioception and reduced postural sway. The aim of this study was to examine the effects of wearable garments on postural regulation in a sample of community-dwelling elderly individuals, aged 65 years. It was hypothesized that wearable garments such as socks would provide stimulation to lower leg mechanoreceptors, and help participants achieve better postural regulation. Participants (N=63) performed a 30-s Romberg balance test protocol under four conditions (barefoot; wearing commercial socks; wearing clinical compression socks; wearing non-clinical compression socks), in a counterbalanced order, with four levels of performance difficulty: (1) standing on a stable surface with open eyes (SO); (2) a stable surface with closed eyes (SC); (3) a foam surface with open eyes (FO); and (4) a foam surface with closed eyes (FC). Centre of pressure (CoP) measurements included postural sway area (C90 area), trace length (TL) and sway velocity. Thirty-five participants (55.6%) showed positive effects of wearing the socks (responded group). In the responded group, it was revealed that socks showed significant differences in SO, SC and FO conditions for the two CoP measurements - TL and sway velocity (p < 0.05). In contrast, in the non-responded group, barefoot condition significantly decreased the TL and velocity in the SO condition. From the positive effects observed in the responded group, it is possible that wearable garments provide sensory cues that could interact with a biological cueing system to enhance performance in the postural regulation system. This study suggests that individuals respond to the socks treatments differently and future research should be undertaken to examine the factors that benefited the responded group of participants.

Keywords: community-dwelling, elderly adults, postural regulation, wearable garments

Procedia PDF Downloads 305
1987 Fuzzy Logic Based Sliding Mode Controller for a New Soft Switching Boost Converter

Authors: Azam Salimi, Majid Delshad

Abstract:

This paper presents a modified design of a sliding mode controller based on fuzzy logic for a New ZVThigh step up DC-DC Converter . Here a proportional - integral (PI)-type current mode control is employed and a sliding mode controller is designed utilizing fuzzy algorithm. Sliding mode controller guarantees robustness against all variations and fuzzy logic helps to reduce chattering phenomenon due to sliding controller, in that way efficiency increases and error, voltage and current ripples decreases. The proposed system is simulated using MATLAB / SIMULINK. This model is tested under variations of input and reference voltages and it was found that in comparison with conventional sliding mode controllers they perform better.

Keywords: switching mode power supplies, DC-DC converters, sliding mode control, robustness, fuzzy control, current mode control, non-linear behavior

Procedia PDF Downloads 506
1986 Optimizing Approach for Sifting Process to Solve a Common Type of Empirical Mode Decomposition Mode Mixing

Authors: Saad Al-Baddai, Karema Al-Subari, Elmar Lang, Bernd Ludwig

Abstract:

Empirical mode decomposition (EMD), a new data-driven of time-series decomposition, has the advantage of supposing that a time series is non-linear or non-stationary, as is implicitly achieved in Fourier decomposition. However, the EMD suffers of mode mixing problem in some cases. The aim of this paper is to present a solution for a common type of signals causing of EMD mode mixing problem, in case a signal suffers of an intermittency. By an artificial example, the solution shows superior performance in terms of cope EMD mode mixing problem comparing with the conventional EMD and Ensemble Empirical Mode decomposition (EEMD). Furthermore, the over-sifting problem is also completely avoided; and computation load is reduced roughly six times compared with EEMD, an ensemble number of 50.

Keywords: empirical mode decomposition (EMD), mode mixing, sifting process, over-sifting

Procedia PDF Downloads 360
1985 Optimal Closed-loop Input Shaping Control Scheme for a 3D Gantry Crane

Authors: Mohammad Javad Maghsoudi, Z. Mohamed, A. R. Husain

Abstract:

Input shaping has been utilized for vibration reduction of many oscillatory systems. This paper presents an optimal closed-loop input shaping scheme for control of a three dimensional (3D) gantry crane system including. This includes a PID controller and Zero Vibration shaper which consider two control objectives concurrently. The control objectives are minimum sway of a payload and fast and accurate positioning of a trolley. A complete mathematical model of a lab-scaled 3D gantry crane is simulated in Simulink. Moreover, by utilizing PSO algorithm and a proposed scheme the controller is designed to cater both control objectives concurrently. Simulation studies on a 3D gantry crane show that the proposed optimal controller has an acceptable performance. The controller provides good position response with satisfactory payload sway in both rail and trolley responses.

Keywords: 3D gantry crane, input shaping, closed-loop control, optimal scheme, PID

Procedia PDF Downloads 387
1984 The Behavior of The Zeros of Bargmann Analytic Functions for Multiple-Mode Systems

Authors: Muna Tabuni

Abstract:

The paper contains an investigation of the behavior of the Zeros of Bargmann functions for one and two-mode systems. A brief introduction to Harmonic oscillator formalism for one and two-mode is given. The Bargmann analytic representation for one and two-mode has been studied. The zeros of Bargmann analytic function for one-mode are considered. The Q Husimi functions are introduced. The Bargmann functions and the Husimi functions have the same zeros. The Bargmann functions f(z) have exactly q zeros. The evolution time of the zeros are discussed. The zeros of Bargmann analytic functions for two-mode are introduced. Various examples have been given.

Keywords: Bargmann functions, two-mode, zeros, harmonic oscillator

Procedia PDF Downloads 541
1983 A Semiparametric Approach to Estimate the Mode of Continuous Multivariate Data

Authors: Tiee-Jian Wu, Chih-Yuan Hsu

Abstract:

Mode estimation is an important task, because it has applications to data from a wide variety of sources. We propose a semi-parametric approach to estimate the mode of an unknown continuous multivariate density function. Our approach is based on a weighted average of a parametric density estimate using the Box-Cox transform and a non-parametric kernel density estimate. Our semi-parametric mode estimate improves both the parametric- and non-parametric- mode estimates. Specifically, our mode estimate solves the non-consistency problem of parametric mode estimates (at large sample sizes) and reduces the variability of non-parametric mode estimates (at small sample sizes). The performance of our method at practical sample sizes is demonstrated by simulation examples and two real examples from the fields of climatology and image recognition.

Keywords: Box-Cox transform, density estimation, mode seeking, semiparametric method

Procedia PDF Downloads 251
1982 Eye Diagram for a System of Highly Mode Coupled PMD/PDL Fiber

Authors: Suad M. Abuzariba, Liang Chen, Saeed Hadjifaradji

Abstract:

To evaluate the optical eye diagram due to polarization-mode dispersion (PMD), polarization-dependent loss (PDL), and chromatic dispersion (CD) for a system of highly mode coupled fiber with lumped section at any given optical pulse sequence we present an analytical modle. We found that with considering PDL and the polarization direction correlation between PMD and PDL, a system with highly mode coupled fiber with lumped section can have either higher or lower Q-factor than a highly mode coupled system with same root mean square PDL/PMD values. Also we noticed that a system of two highly mode coupled fibers connected together is not equivalent to a system of highly mode coupled fiber when fluctuation is considered

Keywords: polarization mode dispersion, polarization dependent loss, chromatic dispersion, optical eye diagram

Procedia PDF Downloads 832
1981 Sensory Integration for Standing Postural Control Among Children and Adolescents with Autistic Spectrum Disorder Compared with Typically Developing Children and Adolescents

Authors: Eglal Y. Ali, Smita Rao, Anat Lubetzky, Wen Ling

Abstract:

Background: Postural abnormalities, rigidity, clumsiness, and frequent falls are common among children with autism spectrum disorders (ASD). The central nervous system’s ability to process all reliable sensory inputs (weighting) and disregard potentially perturbing sensory input (reweighting) is critical for successfully maintaining standing postural control. This study examined how sensory inputs (visual and somatosensory) are weighted and reweighted to maintain standing postural control in children with ASD compared with typically developing (TD) children. Subjects: Forty (20 (TD) and 20 ASD) children and adolescents participated in this study. The groups were matched for age, weight, and height. Participants had normal somatosensory (no somatosensory hypersensitivity), visual, and vestibular perception. Participants with ASD were categorized with severity level 1 according to the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) and Social Responsiveness Scale. Methods: Using one force platform, the center of pressure (COP) was measured during quiet standing for 30 seconds, 3 times first standing on stable surface with eyes open (Condition 1), followed by randomization of the following 3 conditions: Condition 2 standing on stable surface with eyes closed, (visual input perturbed); Condition 3 standing on compliant foam surface with eyes open, (somatosensory input perturbed); and Condition 4 standing on compliant foam surface with eyes closed, (both visual and somatosensory inputs perturbed). Standing postural control was measured by three outcome measures: COP sway area, COP anterior-posterior (AP), and mediolateral (ML) path length (PL). A repeated measure mixed model Analysis of Variance was conducted to determine whether there was a significant difference between the two groups in the mean of the three outcome measures across the four conditions. Results: According to all three outcome measures, both groups showed a gradual increase in postural sway from condition 1 to condition 4. However, TD participants showed a larger postural sway than those with ASD. There was a significant main effect of condition on three outcome measures (p< 0.05). Only the COP AP PL showed a significant main effect of the group (p<0.05) and a significant group by condition interaction (p<0.05). In COP AP PL, TD participants showed a significant difference between condition 2 and the baseline (p<0.05), whereas the ASD group did not. This suggests that the ASD group did not weight visual input as much as the TD group. A significant difference between conditions for the ASD group was seen only when participants stood on foam regardless of the visual condition, suggesting that the ASD group relied more on the somatosensory inputs to maintain the standing postural control. Furthermore, the ASD group exhibited significantly smaller postural sway compared with TD participants during standing on the stable surface, whereas the postural sway of the ASD group was close to that of the TD group on foam. Conclusion: These results suggest that participants with high functioning ASD (level 1, no somatosensory hypersensitivity in ankles and feet) over-rely on somatosensory inputs and use a stiffening strategy for standing postural control. This deviation in the reweighting mechanism might explain the postural abnormalities mentioned above among children with ASD.

Keywords: autism spectrum disorders, postural sway, sensory weighting and reweighting, standing postural control

Procedia PDF Downloads 35
1980 Sensory Weighting and Reweighting for Standing Postural Control among Children and Adolescents with Autistic Spectrum Disorder Compared with Typically Developing Children and Adolescents

Authors: Eglal Y. Ali, Smita Rao, Anat Lubetzky, Wen Ling

Abstract:

Background: Postural abnormalities, rigidity, clumsiness, and frequent falls are common among children with autism spectrum disorders (ASD). The central nervous system’s ability to process all reliable sensory inputs (weighting) and disregard potentially perturbing sensory input (reweighting) is critical for successfully maintaining standing postural control. This study examined how sensory inputs (visual and somatosensory) are weighted and reweighted to maintain standing postural control in children with ASD compared with typically developing (TD) children. Subjects: Forty (20 (TD) and 20 ASD) children and adolescents participated in this study. The groups were matched for age, weight, and height. Participants had normal somatosensory (no somatosensory hypersensitivity), visual, and vestibular perception. Participants with ASD were categorized with severity level 1 according to the Diagnostic and Statistical Manual of Mental Disorders (DSM-V) and Social Responsiveness Scale. Methods: Using one force platform, the center of pressure (COP) was measured during quiet standing for 30 seconds, 3 times first standing on stable surface with eyes open (Condition 1), followed by randomization of the following 3 conditions: Condition 2 standing on stable surface with eyes closed, (visual input perturbed); Condition 3 standing on a compliant foam surface with eyes open, (somatosensory input perturbed); and Condition 4 standing on a compliant foam surface with eyes closed, (both visual and somatosensory inputs perturbed). Standing postural control was measured by three outcome measures: COP sway area, COP anterior-posterior (AP), and mediolateral (ML) path length (PL). A repeated measure mixed model analysis of variance was conducted to determine whether there was a significant difference between the two groups in the mean of the three outcome measures across the four conditions. Results: According to all three outcome measures, both groups showed a gradual increase in postural sway from condition 1 to condition 4. However, TD participants showed a larger postural sway than those with ASD. There was a significant main effect of the condition on three outcome measures (p< 0.05). Only the COP AP PL showed a significant main effect of the group (p<0.05) and a significant group by condition interaction (p<0.05). In COP AP PL, TD participants showed a significant difference between condition 2 and the baseline (p<0.05), whereas the ASD group did not. This suggests that the ASD group did not weigh visual input as much as the TD group. A significant difference between conditions for the ASD group was seen only when participants stood on foam regardless of the visual condition, suggesting that the ASD group relied more on the somatosensory inputs to maintain the standing postural control. Furthermore, the ASD group exhibited significantly smaller postural sway compared with TD participants during standing on a stable surface, whereas the postural sway of the ASD group was close to that of the TD group on foam. Conclusion: These results suggest that participants with high-functioning ASD (level 1, no somatosensory hypersensitivity in ankles and feet) over-rely on somatosensory inputs and use a stiffening strategy for standing postural control. This deviation in the reweighting mechanism might explain the postural abnormalities mentioned above among children with ASD.

Keywords: autism spectrum disorders, postural sway, sensory weighting and reweighting, standing postural control

Procedia PDF Downloads 80
1979 Fast Terminal Sliding Mode Controller For Quadrotor UAV

Authors: Vahid Tabrizi, Reza GHasemi, Ahmadreza Vali

Abstract:

This paper presents robust nonlinear control law for a quadrotor UAV using fast terminal sliding mode control. Fast terminal sliding mode idea is used for introducing a nonlinear sliding variable that guarantees the finite time convergence in sliding phase. Then, in reaching phase for removing chattering and producing smooth control signal, continuous approximation idea is used. Simulation results show that the proposed algorithm is robust against parameter uncertainty and has better performance than conventional sliding mode for controlling a quadrotor UAV.

Keywords: quadrotor UAV, fast terminal sliding mode, second order sliding mode t

Procedia PDF Downloads 506
1978 Efficiency of Virtual Reality Exercises with Nintendo Wii System on Balance and Independence in Motor Functions in Hemiparetic Patients: A Randomized Controlled Study

Authors: Ayça Utkan Karasu, Elif Balevi Batur, Gülçin Kaymak Karataş

Abstract:

The aim of this study was to examine the efficiency of virtual reality exercises with Nintendo Wii system on balance and independence in motor functions. This randomized controlled assessor-blinded study included 23 stroke inpatients with hemiparesis all within 12 months poststroke. Patients were randomly assigned to control group (n=11) or experimental group (n=12) via block randomization method. Control group participated in a conventional balance rehabilitation programme. Study group received a four-week balance training programme five times per week with a session duration of 20 minutes in addition to the conventional balance rehabilitation programme. Balance was assessed by the Berg’s balance scale, the functional reach test, the timed up and go test, the postural assessment scale for stroke, the static balance index. Also, displacement of centre of pressure sway and centre of pressure displacement during weight shifting was calculated by Emed-SX system. Independence in motor functions was assessed by The Functional Independence Measure (FIM) ambulation and FIM transfer subscales. The outcome measures were evaluated at baseline, 4th week (posttreatment), 8th week (follow-up). Repeated measures analysis of variance was performed for each of the outcome measure. Significant group time interaction was detected in the scores of the Berg’s balance scale, the functional reach test, eyes open anteroposterior and mediolateral center of pressure sway distance, eyes closed anteroposterior center of pressure sway distance, center of pressure displacement during weight shifting to effected side, unaffected side and total centre of pressure displacement during weight shifting (p < 0.05). Time effect was statistically significant in the scores of the Berg’s balance scale, the functional reach test, the timed up and go test, the postural assessment scale for stroke, the static balance index, eyes open anteroposterior and mediolateral center of pressure sway distance, eyes closed mediolateral center of pressure sway distance, the center of pressure displacement during weight shifting to effected side, the functional independence measure ambulation and transfer scores (p < 0.05). Virtual reality exercises with Nintendo Wii system combined with a conventional balance rehabilitation programme enhances balance performance and independence in motor functions in stroke patients.

Keywords: balance, hemiplegia, stroke rehabilitation, virtual reality

Procedia PDF Downloads 193
1977 The Magnetized Quantum Breathing in Cylindrical Dusty Plasma

Authors: A. Abdikian

Abstract:

A quantum breathing mode has been theatrically studied in quantum dusty plasma. By using linear quantum hydrodynamic model, not only the quantum dispersion relation of rotation mode but also void structure has been derived in the presence of an external magnetic field. Although the phase velocity of the magnetized quantum breathing mode is greater than that of unmagnetized quantum breathing mode, attenuation of the magnetized quantum breathing mode along radial distance seems to be slower than that of unmagnetized quantum breathing mode. Clearly, drawing the quantum breathing mode in the presence and absence of a magnetic field, we found that the magnetic field alters the distribution of dust particles and changes the radial and azimuthal velocities around the axis. Because the magnetic field rotates the dust particles and collects them, it could compensate the void structure.

Keywords: the linear quantum hydrodynamic model, the magnetized quantum breathing mode, the quantum dispersion relation of rotation mode, void structure

Procedia PDF Downloads 261
1976 Working Mode and Key Technology of Thermal Vacuum Test Software for Spacecraft Test

Authors: Zhang Lei, Zhan Haiyang, Gu Miao

Abstract:

A universal software platform is developed for improving the defects in the practical one. This software platform has distinct advantages in modularization, information management, and the interfaces. Several technologies such as computer technology, virtualization technology, network technology, etc. are combined together in this software platform, and four working modes are introduced in this article including single mode, distributed mode, cloud mode, and the centralized mode. The application area of the software platform is extended through the switch between these working modes. The software platform can arrange the thermal vacuum test process automatically. This function can improve the reliability of thermal vacuum test.

Keywords: software platform, thermal vacuum test, control and measurement, work mode

Procedia PDF Downloads 377
1975 Compact Low-Voltage Biomedical Instrumentation Amplifiers

Authors: Phanumas Khumsat, Chalermchai Janmane

Abstract:

Low-voltage instrumentation amplifier has been proposed for 3-lead electrocardiogram measurement system. The circuit’s interference rejection technique is based upon common-mode feed-forwarding where common-mode currents have cancelled each other at the output nodes. The common-mode current for cancellation is generated by means of common-mode sensing and emitter or source followers with resistors employing only one transistor. Simultaneously this particular transistor also provides common-mode feedback to the patient’s right/left leg to further reduce interference entering the amplifier. The proposed designs have been verified with simulations in 0.18-µm CMOS process operating under 1.0-V supply with CMRR greater than 80dB. Moreover ECG signals have experimentally recorded with the proposed instrumentation amplifiers implemented from discrete BJT (BC547, BC558) and MOSFET (ALD1106, ALD1107) transistors working with 1.5-V supply.

Keywords: electrocardiogram, common-mode feedback, common-mode feedforward, communication engineering

Procedia PDF Downloads 350
1974 Energy Saving Study of Mass Rapid Transit by Optimal Train Coasting Operation

Authors: Artiya Sopharak, Tosaphol Ratniyomchai, Thanatchai Kulworawanichpong

Abstract:

This paper presents an energy-saving study of Mass Rapid Transit (MRT) using an optimal train coasting operation. For the dynamic train movement with four modes of operation, including accelerating mode, constant speed or cruising mode, coasting mode, and braking mode are considered in this study. The acceleration rate, the deceleration rate, and the starting coasting point are taken into account the optimal train speed profile during coasting mode with considering the energy saving and acceptable travel time comparison to the based case with no coasting operation. In this study, the mathematical method as a Quadratic Search Method (QDS) is conducted to carry out the optimization problem. A single train of MRT services between two stations with a distance of 2 km and a maximum speed of 80 km/h is taken to be the case study. Regarding the coasting mode operation, the results show that the longer distance of costing mode, the less energy consumption in cruising mode and the less braking energy. On the other hand, the shorter distance of coasting mode, the more energy consumption in cruising mode and the more braking energy.

Keywords: energy saving, coasting mode, mass rapid transit, quadratic search method

Procedia PDF Downloads 263
1973 Establishment of Bit Selective Mode Storage Covert Channel in VANETs

Authors: Amarpreet Singh, Kimi Manchanda

Abstract:

Intended for providing the security in the VANETS (Vehicular Ad hoc Network) scenario, the covert storage channel is implemented through data transmitted between the sender and the receiver. Covert channels are the logical links which are used for the communication purpose and hiding the secure data from the intruders. This paper refers to the Establishment of bit selective mode covert storage channels in VANETS. In this scenario, the data is being transmitted with two modes i.e. the normal mode and the covert mode. During the communication between vehicles in this scenario, the controlling of bits is possible through the optional bits of IPV6 Header Format. This implementation is fulfilled with the help of Network simulator.

Keywords: covert mode, normal mode, VANET, OBU, on-board unit

Procedia PDF Downloads 337
1972 Inverse Mode Shape Problem of Hand-Arm Vibration (Humerus Bone) for Bio-Dynamic Response Using Varying Boundary Conditions

Authors: Ajay R, Rammohan B, Sridhar K S S, Gurusharan N

Abstract:

The objective of the work is to develop a numerical method to solve the inverse mode shape problem by determining the cross-sectional area of a structure for the desired mode shape via the vibration response study of the humerus bone, which is in the form of a cantilever beam with anisotropic material properties. The humerus bone is the long bone in the arm that connects the shoulder to the elbow. The mode shape is assumed to be a higher-order polynomial satisfying a prescribed set of boundary conditions to converge the numerical algorithm. The natural frequency and the mode shapes are calculated for different boundary conditions to find the cross-sectional area of humerus bone from Eigenmode shape with the aid of the inverse mode shape algorithm. The cross-sectional area of humerus bone validates the mode shapes of specific boundary conditions. The numerical method to solve the inverse mode shape problem is validated in the biomedical application by finding the cross-sectional area of a humerus bone in the human arm.

Keywords: Cross-sectional area, Humerus bone, Inverse mode shape problem, Mode shape

Procedia PDF Downloads 89
1971 Nonlinear Analysis of Postural Sway in Multiple Sclerosis

Authors: Hua Cao, Laurent Peyrodie, Olivier Agnani, Cecile Donze

Abstract:

Multiple sclerosis (MS) is a disease, which affects the central nervous system, and causes balance problem. In clinical, this disorder is usually evaluated using static posturography. Some linear or nonlinear measures, extracted from the posturographic data (i.e. center of pressure, COP) recorded during a balance test, has been used to analyze postural control of MS patients. In this study, the trend (TREND) and the sample entropy (SampEn), two nonlinear parameters were chosen to investigate their relationships with the expanded disability status scale (EDSS) score. Forty volunteers with different EDSS scores participated in our experiments with eyes open (EO) and closed (EC). TREND and two types of SampEn (SampEn1 and SampEn2) were calculated for each combined COP’s position signal. The results have shown that TREND had a weak negative correlation to EDSS while SampEn2 had a strong positive correlation to EDSS. Compared to TREND and SampEn1, SampEn2 showed a better significant correlation to EDSS and an ability to discriminate the MS patients in the EC case. In addition, the outcome of the study suggests that the multi-dimensional nonlinear analysis could provide some information about the impact of disability progression in MS on dynamics of the COP data.

Keywords: balance, multiple sclerosis, nonlinear analysis, postural sway

Procedia PDF Downloads 308
1970 Synchronization of a Perturbed Satellite Attitude Motion using Active Sliding Mode Controller

Authors: Djaouida Sadaoui

Abstract:

In this paper, the design procedure of the active sliding mode controller which is a combination of the active controller and the sliding mode controller is given first and then the problem of synchronization of two satellites systems is discussed for the proposed method. Finally, numerical results are presented to evaluate the robustness and effectiveness of the proposed control strategy.

Keywords: active control, sliding mode control, synchronization, satellite attitude

Procedia PDF Downloads 457
1969 A Study of Traditional Mode in the Framework of Sustainable Urban Transportation

Authors: Juanita, B. Kombaitan, Iwan Pratoyo Kusumantoro

Abstract:

The traditional mode is a non-motorized vehicle powered by human or animal power. The objective of the study was to define the strategy of using traditional modes by the framework of sustainable urban transport in support of urban tourism activities. The study of the traditional mode does not include a modified mode using the engine power as motor tricycles are often called ‘bentor ‘in Indonesia. The use of non-motorized traditional mode in Indonesia has begun to shift, and its use began to be eliminated by the change of propulsion using the machine. In an effort to push back the use of traditional mode one of them with tourism activities. Strategies for the use of traditional modes within the framework of sustainable urban transport are seen from three dimensions: social, economic and environmental. The social dimension related to accessibility and livability, an economic dimension related to traditional modes can promote products and tourist attractions, while the environmental dimension related to the needs of the users/groups with respect to safety, comfort. The traditional mode is rarely noticed by the policy makers, and public opinion in its use needs attention. The involvement of policy-making between stakeholders and the community is needed in the development of sustainable traditional mode strategies in support of urban tourism activities.

Keywords: traditional mode, sustainable, urban, transportation

Procedia PDF Downloads 235
1968 Impact of Instructional Mode and Medium of Instruction on the Learning Outcomes of Secondary Level School Children

Authors: Dipti Parida, Atasi Mohanty

Abstract:

The focus of this research is to examine the interaction effect of flipped teaching and traditional teaching mode across two different medium (English and Odia) of instructional groups. Both Science and History subjects were taken to be taught in the Class- VIII in two different instructional mode/s. In total, 180 students of Class-VIII of both Odia and English medium schools were taken as the samples of this study; 90 participants (each group) were from both English and Odia medium schools ; 45 participants of each of these two groups were again assigned either to flip or traditional teaching method. We have two independent variables and each independent variable with two levels. Medium and mode of instruction are the two independent variables. Medium of instruction has two levels of Odia medium and English medium groups. The mode of instruction has also two levels of flip and traditional teaching method. Here we get 4 different groups, such as Odia medium students with traditional mode of teaching (O.M.T), Odia medium students with flipped mode of teaching (O.M.F), English medium students with traditional mode of teaching (E.M.T) and English medium students with flipped mode of teaching (E.M.F). Before the instructional administration, these four groups were given a test on the concerned topic to be taught. Based on this result, a one-way ANOVA was computed and the obtained result showed that these four groups don’t differ significantly from each other at the beginning. Then they were taught the concerned topic either in traditional or flip mode of teaching method. After that a 2×2×2 repeated measures ANOVA was done to analyze the group differences as well as the learning outcome before and after the teaching. The result table also shows that in post-test the learning outcome is highest in case of English medium students with flip mode of instruction. From the statistical analysis it is clear that the flipped mode of teaching is as effective for Odia medium students as it is for English medium students.

Keywords: medium of instruction, mode of instruction, test mode, vernacular medium

Procedia PDF Downloads 326
1967 Interaction of the Circumferential Lamb Wave with Delamination in the Middle of Pipe Wall

Authors: Li Ziming, He Cunfu, Liu Zenghua

Abstract:

With aim for delamination type defects detection in manufacturing process of seamless pipe,this paper studies the interaction of the circumferential lamb wave with delamination in aluminum pipe.The delamination is located in the middle of pipe wall.A numerical study is carried out,the circumferential lamb wave used here is CL0 mode,which is generated with a finite element method code.Wave structures from the simulation are compared with theoretical results to verify the model’s accuracy.Delamination along the circumferential direction is established by demerging nodes of the same coordinates.When CL0 mode is incident at the entrance and exit of a delamination,it generates new mode-CL1,undergoes multiple reverberation and mode conversions between the two ends of the delamination. Signals of different receptions are obtained to provide insight in using CL0 mode for locating the delamination.

Keywords: circumferential lamb wave, delamination, FEM, seamless pipe

Procedia PDF Downloads 286
1966 Trajectory Tracking of a 2-Link Mobile Manipulator Using Sliding Mode Control Method

Authors: Abolfazl Mohammadijoo

Abstract:

In this paper, we are investigating the sliding mode control approach for trajectory tracking of a two-link-manipulator with a wheeled mobile robot in its base. The main challenge of this work is the dynamic interaction between mobile base and manipulator, which makes trajectory tracking more difficult than n-link manipulators with a fixed base. Another challenging part of this work is to avoid from chattering phenomenon of sliding mode control that makes lots of damages for actuators in real industrial cases. The results show the effectiveness of the sliding mode control approach for the desired trajectory.

Keywords: mobile manipulator, sliding mode control, dynamic interaction, mobile robotics

Procedia PDF Downloads 151
1965 Sliding Mode Controller for Active Suspension System on a Passenger Car Model

Authors: Nouby M. Ghazaly, Ahmed O. Moaaz, Mostafa Makrahy

Abstract:

The main purpose of a car suspension system is to reduce the vibrations resulting from road roughness. The main objective of this research paper is to decrease vibration and improve passenger comfort through controlling car suspension system using sliding mode control techniques. The mathematical model for passive and active suspensions systems for quarter car model which subject to excitation from different road profiles is obtained. The active suspension system is synthesized based on sliding mode control for a quarter car model. The performance of the sliding mode control is determined through computer simulations using MATLAB and SIMULINK toolbox. The simulated results plotted in time domain, and root mean square values. It is found that active suspension system using sliding mode control improves the ride comfort and decrease vibration.

Keywords: quarter car model, active suspension system, sliding mode control, road profile

Procedia PDF Downloads 274
1964 Sliding Mode Control of an Internet Teleoperated PUMA 600 Robot

Authors: Abdallah Ghoul, Bachir Ouamri, Ismail Khalil Bousserhane

Abstract:

In this paper, we have developed a sliding mode controller for PUMA 600 manipulator robot, to control the remote robot a teleoperation system was developed. This system includes two sites, local and remote. The sliding mode controller is installed at the remote site. The client asks for a position through an interface and receives the real positions after running of the task by the remote robot. Both sites are interconnected via the Internet. In order to verify the effectiveness of the sliding mode controller, that is compared with a classic PID controller. The developed approach is tested on a virtual robot. The results confirmed the high performance of this approach.

Keywords: internet, manipulator robot, PID controller, remote control, sliding mode, teleoperation

Procedia PDF Downloads 294
1963 Sliding Mode Control of a Bus Suspension System

Authors: Mujde Turkkan, Nurkan Yagiz

Abstract:

The vibrations, caused by the irregularities of the road surface, are to be suppressed via suspension systems. In this paper, sliding mode control for a half bus model with air suspension system is presented. The bus is modelled as five degrees of freedom (DoF) system. The mathematical model of the half bus is developed using Lagrange Equations. For time domain analysis, the bus model is assumed to travel at certain speed over the bump road. The numerical results of the analysis indicate that the sliding mode controllers can be effectively used to suppress the vibrations and to improve the ride comfort of the busses.

Keywords: active suspension system, air suspension, bus model, sliding mode control

Procedia PDF Downloads 360