Search results for: stenosis nature
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4257

Search results for: stenosis nature

4257 A Comparative CFD Study on the Hemodynamics of Flow through an Idealized Symmetric and Asymmetric Stenosed Arteries

Authors: B. Prashantha, S. Anish

Abstract:

The aim of the present study is to computationally evaluate the hemodynamic factors which affect the formation of atherosclerosis and plaque rupture in the human artery. An increase of atherosclerosis disease in the artery causes geometry changes, which results in hemodynamic changes such as flow separation, reattachment, and adhesion of new cells (chemotactic) in the artery. Hence, geometry plays an important role in the determining the nature of hemodynamic patterns. Influence of stenosis in the non-bifurcating artery, under pulsatile flow condition, has been studied on an idealized geometry. Analysis of flow through symmetric and asymmetric stenosis in the artery revealed the significance of oscillating shear index (OSI), flow separation, low WSS zones and secondary flow patterns on plaque formation. The observed characteristic of flow in the post-stenotic region highlight the importance of plaque eccentricity on the formation of secondary stenosis on the arterial wall.

Keywords: atherosclerotic plaque, oscillatory shear index, stenosis nature, wall shear stress

Procedia PDF Downloads 322
4256 Anal Repair and Diamond Flap in Moderate Anal Stenosis Patient After an Open Hemorrhoidectomy Surgery: A Case Report

Authors: Andriana Purnama, Reno Rudiman, Kezia Christy

Abstract:

Anal stenosis which develops due to anoderm scarring usually caused by secondary to surgical trauma, has become common, causing significant decrease patient’s quality of life. Even though mild anal stenosis was treated with non-surgical treatment, but surgical reconstruction in unavoidable for moderate to severe anal stenosis that cause distressing, severe anal pain and inability to defecate. In our study, we intend to share our result with the use of diamond flap in treatment of anal stenosis. This case report illustrates a 57-year-old male patient who presented with difficulty and discomfort in defecation caused by anal stenosis after 2 years of open hemorrhoidectomy surgery. At physical examination, there was requirement of forceful dilatation when the index finger was inserted or precisely 6mm as measured by hegar dilator (moderate anal stenosis). Blood test result was within normal limits. The patient underwent anal repair and diamond flap where the scar tissue at 6 and 9 o’clock directions was excised and diamond graft was incised carefully while paying attention to the vascular supply. Finally, the graft was fixated without any tension to the anal canal, resulting in diameter of 2 cm after operation. After 2 days post operation, the patient was in stable condition, without any complication, and discharged. There was no abnormality concerning the stool. Ten days after the operation, diamond flap was in normal condition and without any complication. He was scheduled for futher follow up at the Digestive Surgery Department. Anal stenosis due to overzealous hemorrhoidectomy is a complication that is preventable when performed in experienced hands. Diamond flap was one of the options for the anal stenosis treatment with less complication.

Keywords: anal stenosis, diamond flap, post hemorrhoidectomy, anal repair

Procedia PDF Downloads 62
4255 Correction of Urinary Incontinence in Severe Spinal Canal Stenosis, Treated Patients

Authors: Ilirian Laçi, Alketa Spahiu

Abstract:

Ageing causes an increase in the number of patients with spinal canal stenosis. Most of the patients have back pain, leg pain, numbness of the legs, as well as urinary incontinence as a very common symptoms. Urinary incontinence impairs the quality of life. Correction of the symptom of urinary incontinence is possible in the early and adequate treatment of spinal stenosis. Methods: This study observed patients with urinary incontinence and spinal canal stenosis. These patients underwent mechanical decompression of the spinal stenosis through surgery. At the same time, these patients were observed clinically with clinical consultations. Cystoscopy and urodynamic tests were conducted at intervals of 2 and 6 months. As a result of treatment, 60% of patients did recover. The patients in this group who benefit from treatment were the patients who were early diagnosed and treated. Conclusions: An important factor in the prognosis of this pathology is the early diagnosis and treatment. The proper treatment of this pathology makes it curable in most cases. An important role in this pathology is played by the neurosurgeon. Surgery accompanied by laminotomy and mechanical decompression is the best way of treatment. Other factors that played a role in this pathology are also a large number of childbirths for women, obesity, etc.

Keywords: urinary incontinence, quality of life, spinal canal stenosis, early diagnosis, treatment

Procedia PDF Downloads 71
4254 Simulation to Detect Virtual Fractional Flow Reserve in Coronary Artery Idealized Models

Authors: Nabila Jaman, K. E. Hoque, S. Sawall, M. Ferdows

Abstract:

Coronary artery disease (CAD) is one of the most lethal diseases of the cardiovascular diseases. Coronary arteries stenosis and bifurcation angles closely interact for myocardial infarction. We want to use computer-aided design model coupled with computational hemodynamics (CHD) simulation for detecting several types of coronary artery stenosis with different locations in an idealized model for identifying virtual fractional flow reserve (vFFR). The vFFR provides us the information about the severity of stenosis in the computational models. Another goal is that we want to imitate patient-specific computed tomography coronary artery angiography model for constructing our idealized models with different left anterior descending (LAD) and left circumflex (LCx) bifurcation angles. Further, we want to analyze whether the bifurcation angles has an impact on the creation of narrowness in coronary arteries or not. The numerical simulation provides the CHD parameters such as wall shear stress (WSS), velocity magnitude and pressure gradient (PGD) that allow us the information of stenosis condition in the computational domain.

Keywords: CAD, CHD, vFFR, bifurcation angles, coronary stenosis

Procedia PDF Downloads 132
4253 Expression of uPA, tPA, and PAI-1 in Calcified Aortic Valves

Authors: Abdullah M. Alzahrani

Abstract:

Our physiopathological assumption is that u-PA, t-PA, and PAI-1 are released by calcified aortic valves and play a role in the calcification of these valves. Sixty-five calcified aortic valves were collected from patients suffering from aortic stenosis. Each valve was incubated for 24 hours in culture medium. The supernatants were used to measure u-PA, t-PA, and PAI-1 concentrations; the valve calcification was evaluated using biphotonic absorptiometry. Aortic stenosis valves expressed normal plasminogen activators concentrations and overexpressed PAI-1 (u-PA, t-PA, and PAI-1 mean concentrations were, resp., 1.69 ng/mL ± 0.80, 2.76 ng/mL ± 1.33, and 53.27 ng/mL ± 36.39). There was no correlation between u-PA and PAI-1 (r = 0.3) but t-PA and PAI-1 were strongly correlated with each other (r = 0.6). Over expression of PAI-1 was proportional to the calcium content of theAS valves. Our results demonstrate a consistent increase of PAI-1 proportional to the calcification. The over expression of PAI-1 may be useful as a predictive indicator in patients with aortic stenosis.

Keywords: aortic valve, PAI-1, tPA gene, uPA gene

Procedia PDF Downloads 447
4252 The Evaluation of Caustic and Corrosive Poisoning in Children

Authors: Sabiha Sahin

Abstract:

Introduction: We have planned this study because of the increasing number of corrosive substance poisoning who admitted to the Pediatric Emergency Department. Method: 636 corrosive substance poisoning cases applied to the Osmangazi University PED between 1 January 2015 - 31 December 2017 were retrospectively analyzed. Results: 438 (69%) cases were male.The poisoning rate of groups 0-4 was significantly higher and occurred by accident. A total of 616 cases (96.9%) were poisoned by the oral route, and 20 cases were poisoned by inhalation.462 Patients were admitted to the hospital within an hour (72.8%). Of the 134 patients who had only erosion and redness around the mouth, 24 patients had salivation and dysphagia symptoms besides these. Of the 28 cases of 158 patients with symptoms, eusaphegeal stenosis was detected. on third day examination. Although there was no statistically significant correlation between esophageal stenosis and erosion and redness around the mouth, there was a statistically significant correlation between dysphagia and salivation between esophageal stenosis Conclusion: The increased salivation and the dysphagia are important signs of risk of devoloping esophageal stenosis at first examination corrosive poisoning in children.

Keywords: caustic, corrosive, poisoning, children

Procedia PDF Downloads 127
4251 Efficacy of Hemi-Facetectomy in Treatment of Lumbar Foraminal Stenosis

Authors: Manoj Deepak, N. Mathivanan, K. Venkatachalam

Abstract:

Nerve root stenosis is one of the main cause for back pain. There are many methods both conservative and surgical to treat this disease. It is pertinent to decompress the spine to a proper extent so as to avoid the recurrence of symptoms. But too much of an aggressive approach also has its disadvantages. We present one of the methods to effectively decompress the nerve with better results. Our study was carried out in 52 patients with foramina stenosis between 2008 to 2011.We carried out the surgical procedure of shaving off the medial part of the facet joint so as to decompress the root. We selected those patients who had symptoms of claudication for more than 2 years. They had no signs of instability and they underwent conservative treatment for a period of 2 months before the procedure. Oswersty scoring was used to record the functional level of the patient before and after the procedure. All patients were followed up for a period of minimum 2.5 years. After evaluation for a minimum of 2.5 years, 34 patients had no evidence of recurrence of symptoms with improvement in the functional level.7 patients complained of minimal pain but their functional quality had improved postop. Six patients had symptoms of lumbar canal disease which reduced with conservative treatment. 5 patients required spinal fusion surgeries in the later period. Conclusion: Thus, we can effectively conclude that our procedure is safe and effective in reducing the symptoms in those patients with neurogenic claudication.

Keywords: facetectoemy, stenosis, decompression, Lumbar Foraminal Stenosis, hemi-facetectomy

Procedia PDF Downloads 317
4250 Geometrical Fluid Model for Blood Rheology and Pulsatile Flow in Stenosed Arteries

Authors: Karan Kamboj, Vikramjeet Singh, Vinod Kumar

Abstract:

Considering blood to be a non-Newtonian Carreau liquid, this indirect numerical model investigates the pulsatile blood flow in a constricted restricted conduit that has numerous gentle stenosis inside the view of an increasing body speed. Asymptotic answers are obtained for the flow rate, pressure inclination, speed profile, sheer divider pressure, and longitudinal impedance to stream after the use of the twofold irritation approach to the problem of the succeeding non-straight limit esteem. It has been observed that the speed of the blood increases when there is an increase in the point of tightening of the conduit, the body speed increase, and the power regulation file. However, this rheological manner of behaving changes to one of longitudinal impedance to stream and divider sheer pressure when each of the previously mentioned boundaries increases. It has also been seen that the sheer divider pressure in the bloodstream greatly increases when there is an increase in the maximum depth of the stenosis but that it significantly decreases when there is an increase in the pulsatile Reynolds number. This is an interesting phenomenon. The assessments of the amount of growth in the longitudinal resistance to flow increase overall with the increment of the maximum depth of the stenosis and the Weissenberg number. Additionally, it is noted that the average speed of blood increases noticeably with the growth of the point of tightening of the corridor, and body speed increases border. This is something that can be observed.

Keywords: geometry of artery, pulsatile blood flow, numerous stenosis

Procedia PDF Downloads 67
4249 Associations of Vitamin D Receptor Polymorphisms with Coronary Artery Diseases

Authors: Elham Sharif, Nasser Rizk, Sirin Abu Aqel, Ofelia Masoud

Abstract:

Background: Previous studies have investigated the association of rs1544410, rs7975232 and rs731236 polymorphisms in vitamin D receptor gene and its impact on diseases such as cancer, diabetes and hypertension in different ethnic backgrounds. Aim: The aim of this study is to investigate the association between VDR polymorphisms using three SNP’s (rs1544410, rs7975232 and rs731236) and the severity of the significant lesion in coronary arteries among angiographically diagnosed CAD. Methods: A prospective-retrospective study was conducted on 192 CAD patients enrolled from the cardiology department-Heart Hospital HMC, grouped in 96 subjects with significant stenosis and 96 with non-significant stenosis with a mean age between 30 and 75 years old. Genotyping was performed for the following SNPs rs1544410, rs7975232 and rs731236 using TaqMan assay by the Real Time PCR, ABI 7500 in Health Sciences Labs at Qatar University Biomedical Research Center. Results: The results showed that both groups have matched age and gender distribution but patients with the significant stenosis have significantly higher; BMI (p=0.047); smoking status (p=0.039); FBS (p= 0.031); CK-MB (p=0.025) and Troponin (p=0.002) than the patients with non–significant lesion. Among the traditional risk factors, smoking increases the odds of the severe stenotic lesion in CAD patients by 1.984, with 95% CI between 1.024 – 7.063, with p= 0.042.HWE showed deviations of the rs1544410 and rs731236 among the study subjects. The most frequent genotype in distribution of rs7975232 is the AA among the significant stenosis patients, while the heterozygous AC was the frequent genotype in distribution among the non-significant stenosis group. The carriers of CC genotype in rs7975232 increased the risk of having significant coronary arteries stenotic lesion by 1.83 with 95% CI (1.020 – 3.280), p=0.043. No association was found between the rs7975232 with vitamin D and VDBP. Conclusion: There is a significant association between rs7975232 and the severity of CAD lesion. The carrier of CC genotype in rs7975232 increased the risk of having significant coronary arteries atherosclerotic lesion especially in patients with smoking history independent of vitamin D.

Keywords: vitamin D, vitamin D receptor, polymorphism, coronary harat disease

Procedia PDF Downloads 290
4248 Predictors of Clinical Failure After Endoscopic Lumbar Spine Surgery During the Initial Learning Curve

Authors: Daniel Scherman, Daniel Madani, Shanu Gambhir, Marcus Ling Zhixing, Yingda Li

Abstract:

Objective: This study aims to identify clinical factors that may predict failed endoscopic lumbar spine surgery to guide surgeons with patient selection during the initial learning curve. Methods: This is an Australasian prospective analysis of the first 105 patients to undergo lumbar endoscopic spine decompression by 3 surgeons. Modified MacNab outcomes, Oswestry Disability Index (ODI) and Visual Analogue Score (VAS) scores were utilized to evaluate clinical outcomes at 6 months postoperatively. Descriptive statistics and Anova t-tests were performed to measure statistically significant (p<0.05) associations between variables using GraphPad Prism v10. Results: Patients undergoing endoscopic lumbar surgery via an interlaminar or transforaminal approach have overall good/excellent modified MacNab outcomes and a significant reduction in post-operative VAS and ODI scores. Regardless of the anatomical location of disc herniations, good/excellent modified MacNab outcomes and significant reductions in VAS and ODI were reported post-operatively; however, not in patients with calcified disc herniations. Patients with central and foraminal stenosis overall reported poor/fair modified MacNab outcomes. However, there were significant reductions in VAS and ODI scores post-operatively. Patients with subarticular stenosis or an associated spondylolisthesis reported good/excellent modified MacNab outcomes and significant reductions in VAS and ODI scores post-operatively. Patients with disc herniation and concurrent degenerative stenosis had generally poor/fair modified MacNab outcomes. Conclusion: The outcomes of endoscopic spine surgery are encouraging, with a low complication and reoperation rate. However, patients with calcified disc herniations, central canal stenosis or a disc herniation with concurrent degenerative stenosis present challenges during the initial learning curve and may benefit from traditional open or other minimally invasive techniques.

Keywords: complications, lumbar disc herniation, lumbar endoscopic spine surgery, predictors of failed endoscopic spine surgery

Procedia PDF Downloads 92
4247 Characteristics of Patients Undergoing Subclavian Artery Revascularization in Latvia: A Retrospective Analysis

Authors: Majid Shahbazi

Abstract:

Subclavian artery stenosis (SAS) is a common vascular disease that can cause a range of symptoms, from arm fatigue and weakness to ischemic stroke. Revascularization procedures, such as percutaneous transluminal angioplasty and stenting, are widely used to treat SAS and improve blood flow to the affected arm. However, the optimal management of patients with SAS is still unclear, and further research is needed to evaluate the safety and efficacy of different treatment options. This study aims to investigate the characteristics of patients with SAS who underwent revascularization procedures in Latvia (Specifically RAKUS). The research part of this paper aims to describe and analyze the demographics, comorbidities, diagnostic methods, types of revascularization procedures, and antiaggregant therapy used. The goal of this study is to provide insights into the current clinical practice in Latvia and help future treatment decision-makers. To achieve this aim, a retrospective study of 76 patients with SAS who underwent revascularization procedures was performed. After statistical analysis of the data, the study provided insights into the characteristics and management of patients with SAS in Latvia, highlighting the most observed comorbidities in these patients, the preferred diagnostic methods, and the most performed procedures. These findings can inform clinical decision-making and may have implications for the management of patients with subclavian artery stenosis in Latvia.

Keywords: subclavian artery stenosis, revascularization, characteristics of patients, comorbidities, retrospective analysis

Procedia PDF Downloads 64
4246 Upregulation of CD40/CD40L System in Rheumatic Mitral Stenosis With or Without Atrial Fibrillation

Authors: Azzam H., Abousamra N. K., Wafa A. A., Hafez M. M., El-Gilany A. H.

Abstract:

Platelet activation occurs in peripheral blood of patients with rheumatic mitral stenosis (MS) and atrial fibrillation (AF) and could be related to abnormal thrombogenesis. The CD40/CD40 ligand (CD40L) which reflects platelet activation, mediate a central role in thrombotic diseases. However, the role of CD40/CD40L system in rheumatic MS with or without AF remains unclear. Expressions of CD40 on monocytes and CD40L on platelets were determined by whole blood flow cytometry and serum levels of soluble CD40L were measured by enzyme-linked immunosorbent assay in group 1 (19 patients with MS) and group 2 (20 patients with MS and AF) compared to group 3 (10 controls). Patients with groups 1 and 2 had a significant increase in expression of CD40 on monocytes (P1 and P2 = 0.000) and serum levels of sCD40L (P1 = 0.014 and P2 = 0.033, respectively), but nonsignificant increase in expression of CD40L on platelets (P1 = 0.109 and P2 = 0.060, respectively) as compared to controls. There were no significant difference in all the parameters in group 1 compared to group 2. Correlation analysis demonstrated that there was a significant direct relationship between the severity of MS and serum levels of sCD40L (r = -0.469, p = 0.043). In conclusion, rheumatic MS patients with or without AF had upregulation of the CD40/CD40L system as well as elevated sCD40L levels. The levels of sCD40L had a significantly direct relationship with the severity of MS and it was the stenotic mitral valve, not AF, that had a significant impact on platelet activation.

Keywords: CD40, CD40L, mitral stenosis, atrial fibrillation

Procedia PDF Downloads 64
4245 Modified Preputial Urethrostomy as a Salvage Procedure in Four Dogs

Authors: Thomas Giansetto, Olivier Broux, Géraldine Bolen, Stéphanie Claeys

Abstract:

Objective: To describe a modified preputial urethrostomy in four dogs. Study design: Short case series. Animals: Four male dogs were treated by the modified preputial urethrostomy, three because of urethral stenosis, and one because of severe complications following perineal urethrostomy. Methods: Four dogs were presented for dysuria and urinary obstruction. secondary to urethral stenosis or tear. Obstruction was treated with a modified preputial urethrostomy. Results: Four dogs had resolution of dysuria with a modified preputial urethrostomy without penile amputation. None of the dogs presented signs of dysuria, urinary tract infection, or dermatitis postoperatively. Two dogs showed signs of urinary incontinence 15 days and one month postoperatively. Conclusion: The modified preputial urethrostomy resulted in a favorable prognosis and may be an alternative to prepubic urethrostomy in male dogs.

Keywords: urethrostomy, preputial, technique, urogenital

Procedia PDF Downloads 120
4244 Blood Flow in Stenosed Arteries: Analytical and Numerical Study

Authors: Shashi Sharma, Uaday Singh, V. K. Katiyar

Abstract:

Blood flow through a stenosed tube, which is of great interest to mechanical engineers as well as medical researchers. If stenosis exists in an artery, normal blood flow is disturbed. The deposition of fatty substances, cholesterol, cellular waste products in the inner lining of an artery results to plaque formation .The present study deals with a mathematical model for blood flow in constricted arteries. Blood is considered as a Newtonian, incompressible, unsteady and laminar fluid flowing in a cylindrical rigid tube along the axial direction. A time varying pressure gradient is applied in the axial direction. An analytical solution is obtained using the numerical inversion method for Laplace Transform for calculating the velocity profile of fluid as well as particles.

Keywords: blood flow, stenosis, Newtonian fluid, medical biology and genetics

Procedia PDF Downloads 488
4243 Nature, Elixir of Architecture: A Contemplation on Human, Nature and Architecture in Islam

Authors: A. Kabiri-Samani, M. J. Seddighi

Abstract:

There is no doubt that a key factor in the manifestation of architecture is the interaction of human and nature. Explaining the type of relationship defined by “the architect” between architecture and nature opens a window towards understanding the theoretical conceptions of the architect as the creator of “architecture”. Now, if these theoretical foundations are put under scrutiny from the viewpoint of Islam, and an architect considers the relationship of human and nature within the context of Islam, he would let nature to manifest itself in architecture. The reasons for such a relationship is explicable in terms of the degree and nature of knowledge of the architect about nature; while the way it comes to existence is explained by defining the force of nature – ruling the entire nature – and its acts. It is by the scientific command of the architect and his mastery in the hermetic force of nature that the material bodies of buildings evolve from artificial to natural. Additionally, the presence of nature creates hermetic architectural spaces for the spiritual development of humans while serving for living at different levels.

Keywords: nature, Islam, cognition, science, presence, elixir

Procedia PDF Downloads 448
4242 A Retrospective Study of Vaginal Stenosis Following Treatment of Cervical Cancers and the Effectiveness of Rehabilitation Interventions

Authors: Manjusha R. Vagal, Shyam K. Shrivastava, Umesh Mahantshetty, Sudeep Gupta, Supriya Chopra, Reena Engineer, Amita Maheshwari, Atul Buduk

Abstract:

Vaginal stenosis is a common side effect associated with pelvic radiotherapy in cervical cancer patients which contributes negatively to woman’s health and prevents adequate vaginal/cervical examination. Vaginal dilation with a dilator is routine practice and is internationally advocated as a prophylactic measure to preserve vaginal patency. This retrospective study was carried out with the aim to know the usefulness of vaginal dilation following pelvic radiation therapy in cervical cancer patients in India. Data from medical records of 183 cervical cancer patients, which met the study criteria, were collected related to the stage of the disease, treatment received, commencement period of dilation post radiation therapy, sexual status and side effects associated to dilation practice. Data related to vaginal dimensions as per the length of insertion of a small, medium and large dilator were collected on regular follow-ups until 36 months and/or more. Vaginal dimensions as measured with the length of medium dilator insertion were used for analysis of dilation therapy results using paired t-test. Patients who underwent vaginal dilation with dilator maintained vaginal patency, also the mean vaginal length significantly increased, from 8.02 cm ± 2.69 to 9.96 ± 2.89 cm with a p value <0.001. There was no significant difference found on vaginal patency with different intervals of initiation of dilation therapy. At the third year and more following dilation therapy, significant increase in vaginal length observed with a p value of 0.0001 in both sexually active and inactive patients. Compilation of vaginal dosage during brachytherapy was inadequate, and hence, the secondary objective of the study to determine the effect of radiotherapy on the outcome of rehabilitation intervention was not studied in detail. This retrospective study has found that dilation therapy with vaginal dilators post pelvic radiotherapy is effective in preventing vaginal stenosis and improving vaginal patency and cannot be substituted with vaginal intercourse. Sexual quality of life assessment in the Indian population needs much attention.

Keywords: dilator, sexually active, vaginal dilation, vaginal stenosis

Procedia PDF Downloads 181
4241 Numerical Simulation of Magnetohydrodynamic (MHD) Blood Flow in a Stenosed Artery

Authors: Sreeparna Majee, G. C. Shit

Abstract:

Unsteady blood flow has been numerically investigated through stenosed arteries to achieve an idea about the physiological blood flow pattern in diseased arteries. The blood is treated as Newtonian fluid and the arterial wall is considered to be rigid having deposition of plaque in its lumen. For direct numerical simulation, vorticity-stream function formulation has been adopted to solve the problem using implicit finite difference method by developing well known Peaceman-Rachford Alternating Direction Implicit (ADI) scheme. The effects of magnetic parameter and Reynolds number on velocity and wall shear stress are being studied and presented quantitatively over the entire arterial segment. The streamlines have been plotted to understand the flow pattern in the stenosed artery, which has significant alterations in the downstream of the stenosis in the presence of magnetic field. The results show that there are nominal changes in the flow pattern when magnetic field strength is enhanced upto 8T which can have remarkable usage to MRI machines.

Keywords: magnetohydrodynamics, blood flow, stenosis, energy dissipation

Procedia PDF Downloads 251
4240 Effects of the Non-Newtonian Viscosity of Blood on Flow Field in a Constricted Artery with a Porous Plaque

Authors: Maedeh Shojaeizadeh, Amirreza Yeganegi

Abstract:

Nowadays many people lose their lives due to cardiovascular diseases. Inappropriate food habits and lack of exercise expedite deposit process of fatty substances on inner surface of blood arteries. This abnormal lump disturbs uniform blood flow and reduces oxygen delivery to active organs. This work presents a numerical simulation of Non-Newtonian blood flow in a stenosis vessel. The vessel is considered as two dimensional channel and plaque area is modelled as a homogenous porous medium. To simulate blood flow reaction around stenosis region, we use C++ code and solve coupled Cauchy, Darcy, governing continuity and energy equations. The analyses results show that viscosity power (n) plays an important role in flow separation and the size of the eddy at the downstream edge of the plaque. It is also observed that with increasing (n) value, temperature discontinuity and likelihood of vessel rupture declined.

Keywords: blood flow, computational fluid dynamic, porosity, power law fluid

Procedia PDF Downloads 435
4239 Nature Writing in Margaret Atwood’s 'The Testaments'

Authors: Natalia Fontes De Oliveira

Abstract:

Nature and women have a long age association that has persisted throughout history, cultures, literature, and arts. Women’s physiological functions of reproduction and childbearing are viewed as closer to nature as a binary opposition to men, who have metaphorically and historically been associated with culture. To liberate from strictures of phallogocentric rhetoric, a radical critique of the categories of nature and culture must be undertaken. This paper proposes that nature writing in Margaret Atwood’s The Testaments is used subversively as a form of rebellion to disrupt the metaphorical relationship between women and nature. In tune with ecofeminist concerns, the imagery rewrites patriarchal paradigms of binary oppositions as the protagonists narrate a complex and plural relationship between nature and women.

Keywords: ecofeminism, Margaret Atwood, nature writing, women's writing

Procedia PDF Downloads 133
4238 Closed Mitral Valvotomy: A Safe and Promising Procedure

Authors: Sushil Kumar Singh, Kumar Rahul, Vivek Tewarson, Sarvesh Kumar, Shobhit Kumar

Abstract:

Objective: Rheumatic mitral stenosis continues to be a major public health problem in developing countries. When the left atrium (LA) is unable to fill the left ventricle (LV) at normal LA pressures due to impaired relaxation and impaired compliance, diastolic dysfunction occurs. The assessment of left ventricular (LV) diastolic function and filling pressures is of clinical importance to identify underlying cardiac disease, its treatment, and to assess prognosis. 2D echocardiography can detect diastolic dysfunction with excellent sensitivity and minimal risk when compared to the gold standard of invasive pressure-volume measurements. Material and Method: This was a one-year study consisting of twenty-nine patients of isolated rheumatic severe mitral stenosis. Data was analyzed preoperative and post operative (at one month follow-up). Transthoracic 2D echocardiographic parameters of the diastolic function are transmitral flow, pulmonary venous flow, mitral annular tissue doppler, and color M-mode doppler. In our study, mitral valve orifice area, ejection fraction, deceleration time, E/A-wave, E/E’-wave, myocardial performance index of left ventricle (Tei index ), and Mitral inflow propagation velocity were included for echocardiographic evaluation. The statistical analysis was performed on SPSS Version 15.0 statistical analysis software. Result: Twenty-nine patients underwent successful closed mitral commissurotomy for isolated mitral stenosis. The outcome measures were observed pre-operatively and at one-month follow-up. The majority of patients were in NYHA grade III (69.0%) in the preoperative period, which improved to NYHA grade I (48.3%) after closed mitral commissurotomy. Post-surgery mitral valve area increased from 0.77 ± 0.13 to 2.32 ± 0.26 cm, ejection fraction increased from 61.38 ± 4.61 to 64.79 ± 3.22. There was a decrease in deceleration time from 231.55 ± 49.31 to 168.28 ± 14.30 ms, E/A ratio from 1.70 ± 0.54 from 0.89 ± 0.39, E/E’ ratio from 14.59 ± 3.34 to 8.86 ± 3.03. In addition, there was improvement in TIE index from 0.50 ± 0.03 to 0.39 ± 0.06 and mitral inflow propagation velocity from 47.28 ± 3.71 to 57.86 ± 3.19 cm/sec. In peri-operative and follow-up, there was no incidence of severe mitral regurgitation (MR). There was no thromboembolic incident and no mortality.

Keywords: closed mitral valvotomy, mitral stenosis, open mitral commissurotomy, balloon mitral valvotomy

Procedia PDF Downloads 52
4237 Metamorphosis in Nature through Adéquation: An Ecocritical Reading of Charles Tomlinson's Poetry

Authors: Zahra Barzegar, Reza Deedari, Behzad Pourgharib

Abstract:

This study examines how metamorphosis in nature is depicted in Charles Tomlinson's poetry through Lawrence Buell's mimesis and referential strategy of adéquation. This study aims to answer the questions that what is the relationship between Tomlinson's selected poems and nature, and how does Tomlinson's poetry bring the reader close to the natural environment. Adéquation is a way that brings the reader close to nature, not by imitating nature but by referring to it imaginatively and creating a stylized image. Using figurative language, namely imagery, metaphor, and analogy, adéquation creates a stylized image of metamorphosis in a nature scene that acts as a middle way between the reader and nature. This paper proves that adéquation reinvents the metamorphosis in natural occurrences in Charles Tomlinson's selected poems. Thus, a reader whose imagination is addressed achieves closeness with nature and a caring outlook toward natural happenings. This article confirms that Tomlinson's poems are potential enough to represent metamorphosis in nature through adéquation. Therefore, the reader understands nature beyond the poem as the poem presents a gist of nature through adéquation.

Keywords: adéquation, metamorphosis, nature, referentiality

Procedia PDF Downloads 152
4236 Structural and Morphological Characterization of Inorganic Deposits in Spinal Ligaments

Authors: Sylwia Orzechowska, Andrzej Wróbel, Eugeniusz Rokita

Abstract:

The mineralization is a curious problem of connective tissues. Factors which may play a decisive role in the regulation of the yellow ligaments (YL) mineralization are still open questions. The aim of the studies was a detailed description of the chemical composition and morphology of mineral deposits in the human yellow ligaments. Investigations of the structural features of deposits were used to explain the impact of various factors on mineralization process. The studies were carried out on 24 YL samples, surgically removed from patients suffer from spinal canal stenosis and the patients who sustained a trauma. The micro-computed tomography was used to describe the morphology of mineral deposits. The X-ray fluorescence method and Fourier transform infrared spectroscopy were applied to determine the chemical composition of the samples. In order to eliminate the effect of blur in microtomographic images, the correction method of partial volume effect was used. The mineral deposits appear in 60% of YL samples, both in patients with a stenosis and following injury. The mineral deposits have a heterogeneous structure and they are a mixture of the tissue and mineral grains. The volume of mineral grains amounts to (1.9 ± 3.4)*10-3 mm3 while the density distribution of grains occurs in two distinct ranges (1.75 - 2.15 and 2.15-2.5) g/cm3. Application of the partial volume effect correction allows accurate calculations by eliminating the averaging effect of gray levels in tomographic images. The B-type carbonate-containing hydroxyapatite constitutes the mineral phase of majority YLs. The main phase of two samples was calcium pyrophosphate dihydrate (CPPD). The elemental composition of minerals in all samples is almost identical. This pathology may be independent on the spine diseases and it does not evoke canal stenosis. The two ranges of grains density indicate two stages of grains growth and the degree of maturity. The presence of CPPD crystals may coexist with other pathologies.

Keywords: FTIR, micro-tomography, mineralization, spinal ligaments

Procedia PDF Downloads 353
4235 Safety and Feasibility of Distal Radial Balloon Aortic Valvuloplasty - The DR-BAV Study

Authors: Alexandru Achim, Tamás Szűcsborus, Viktor Sasi, Ferenc Nagy, Zoltán Jambrik, Attila Nemes, Albert Varga, Călin Homorodean, Olivier F. Bertrand, Zoltán Ruzsa

Abstract:

Aim: Our study aimed to establish the safety and the technical success of distal radial access for balloon aortic valvuloplasty (DR-BAV). The secondary objective was to determine the effectiveness and appropriate role of DR-BAV within half year follow-up. Methods: Clinical and angiographic data from 32 consecutive patients with symptomatic aortic stenosis were evaluated in a prospective pilot single-center study. Between 2020 and 2021, the patients were treated utilizing dual distal radial access with 6-10F compatible balloons. The efficacy endpoint was divided into technical success (successful valvuloplasty balloon inflation at the aortic valve and absence of intra- or periprocedural major complications), hemodynamic success (a reduction of the mean invasive gradient >30%), and clinical success (an improvement of at least one clinical category in the NYHA classification). The safety endpoints were vascular complications (major and minor Valve Academic Research Consortium (VARC)-2 bleeding, diminished or lost arterial pulse or the presence of any pseudo-aneurysm or arteriovenous fistula during the clinical follow-up) and major adverse events, MAEs (the composite of death, stroke, myocardial infarction, and urgent major aortic valve replacement or implantation during the hospital stay and or at one-month follow-up). Results: 32 patients (40 % male, mean age 80 ± 8,5) with severe aortic valve stenosis were included in the study and 4 patients were excluded. Technical success was achieved in all patients (100%). Hemodynamic success was achieved in 30 patients (93,75%). Invasive max and mean gradients were reduced from 73±22 mm Hg and 49±22 mm Hg to 49±19 mm Hg and 20±13 mm Hg, respectively (p = <.001). Clinical success was achieved in 29 patients (90,6%). In total, no major adverse cardiac or cerebrovascular event nor vascular complications (according to VARC 2 criteria) occurred during the intervention. All-cause death at 6 months was 12%. Conclusion: According to our study, dual distal radial artery access is a safe and effective option for balloon aortic valvuloplasty in patients with severe aortic valve stenosis and can be performed in all patients with sufficient lumen diameter. Future randomized studies are warranted to investigate whether this technique is superior to other approaches.

Keywords: mean invasive gradient, distal radial access for balloon aortic valvuloplasty (DR-BAV), aortic valve stenosis, pseudo-aneurysm, arteriovenous fistula, valve academic research consortium (VARC)-2

Procedia PDF Downloads 53
4234 A Mathematical Model of Pulsatile Blood Flow through a Bifurcated Artery

Authors: D. Srinivasacharya, G. Madhava Rao

Abstract:

In this article, the pulsatile flow of blood flow in bifurcated artery with mild stenosis is investigated. Blood is treated to be a micropolar fluid with constant density. The arteries forming bifurcation are assumed to be symmetric about its axes and straight cylinders of restricted length. As the geometry of the stenosed bifurcated artery is irregular, it is changed to regular geometry utilizing the appropriate transformations. The numerical solutions, using the finite difference method, are computed for the flow rate, the shear stress, and the impedance. The influence of time, coupling number, half of the bifurcated angle and Womersley number on shear stress, flow rate and impedance (resistance to the flow) on both sides of the flow divider is shown graphically. It has been observed that the shear stress and flow rate are increasing with increase in the values of Womersley number and bifurcation angle on both sides of the apex. The shear stress is increasing along the inner wall and decreasing along the outer wall of the daughter artery with an increase in the value of coupling number. Further, it has been noticed that the shear stress, flow rate, and impedance are perturbed largely near to the apex in the parent artery due to the presence of backflow near the apex.

Keywords: micropolar fluid, bifurcated artery, stenosis, back flow, secondary flow, pulsatile flow, Womersley number

Procedia PDF Downloads 166
4233 Relationship of Silent Myocardial Ischemia to Erectile Dysfunction in Patients with Diabetes Mellitus

Authors: Ali Kassem, Esam Nada, Amro Abdelhamed, Shigeo Horie

Abstract:

Objective: Diabetes mellitus (DM) is associated with macrovascular complications, including coronary artery disease (CAD), and microvascular complications that contribute to the pathogenesis of erectile dysfunction (ED). On the other hand, silent myocardial ischemia (SMI) is more common in diabetic patients and is a strong predictor of cardiac events and mortality in diabetic and non-diabetic patients. Recently, Multidetector computed tomographic coronary angiography (MDCT-CA) has become a reliable non-invasive imaging modality for screening diabetic patients for SMI. We aim to evaluate the presence of SMI using (MDCT-CA) in patients with type 2DM having ED. Methods: This study evaluated 20 patients (mean age 61.45 ± 10.7 years), with DM and ED without any history of angina or angina equivalent. ED was tested with the Sexual Health Inventory for Men score, erection hardness score (EHS), and maximal penile circumferential change by an erect meter. Results: Of twenty studied patients, coronary artery stenosis was detected in 13 (65%) patients in the form of one-vessel disease (n = 6, 30%), two-vessel disease (n = 2, 10%), and three-vessel disease (n = 5, 25%). Maximum coronary artery stenosis was positively correlated with age (P < 0.016,) and negatively correlated with EHS (P <04). Multivariate regression analysis using age and EHS showed that age was the only independent predictor of SMI (P <04). Conclusion: MDCT-CA is a useful tool to identify SMI in patients with diabetes mellitus and ED. One should consider the possibility of SMI especially in elderly patients with DM who have ED.

Keywords: diabetes mellitus, erectile dysfunction, microvascular, silent ischemia

Procedia PDF Downloads 142
4232 The Effect of Stent Coating on the Stent Flexibility: Comparison of Covered Stent and Bare Metal Stent

Authors: Keping Zuo, Foad Kabinejadian, Gideon Praveen Kumar Vijayakumar, Fangsen Cui, Pei Ho, Hwa Liang Leo

Abstract:

Carotid artery stenting (CAS) is the standard procedure for patients with severe carotid stenosis at high risk for carotid endarterectomy (CAE). A major drawback of CAS is the higher incidence of procedure-related stroke compared with traditional open surgical treatment for carotid stenosis - CEA, even with the use of the embolic protection devices (EPD). As the currently available bare metal stents cannot address this problem, our research group developed a novel preferential covered-stent for carotid artery aims to prevent friable fragments of atherosclerotic plaques from flowing into the cerebral circulation, and yet maintaining the flow of the external carotid artery. The preliminary animal studies have demonstrated the potential of this novel covered-stent design for the treatment of carotid atherosclerotic stenosis. The purpose of this study is to evaluate the effect of membrane coating on the stent flexibility in order to improve the clinical performance of our novel covered stents. A total of 21 stents were evaluated in this study: 15 self expanding bare nitinol stents and 6 PTFE-covered stents. 10 of the bare stents were coated with 11%, 16% and 22% Polyurethane(PU), 4%, 6.25% and 11% EE, as well as 22% PU plus 5 μm Parylene. Different laser cutting designs were performed on 4 of the PTFE covert stents. All the stents, with or without the covered membrane, were subjected to a three-point flexural test. The stents were placed on two supports that are 30 mm apart, and the actuator is applying a force in the exact middle of the two supports with a loading pin with radius 2.5 mm. The loading pin displacement change, the force and the variation in stent shape were recorded for analysis. The flexibility of the stents was evaluated by the lumen area preservation at three displacement bending levels: 5mm, 7mm, and 10mm. All the lumen areas in all stents decreased with the increase of the displacement from 0 to 10 mm. The bare stents were able to maintain 0.864 ± 0.015, 0.740 ± 0.025 and 0.597 ± 0.031of original lumen area at 5 mm, 7 mm and 10mm displacement respectively. For covered stents, the stents with EE coating membrane showed the best lumen area preservation (0.839 ± 0.005, 0.7334 ± 0.043 and 0.559 ± 0.014), whereas, the stents with PU and Parylene coating were only 0.662, 0.439 and 0.305. Bending stiffness was also calculated and compared. These results provided optimal material information and it was crucial for enhancing clinical performance of our novel covered stents.

Keywords: carotid artery, covered stent, nonlinear, hyperelastic, stress, strain

Procedia PDF Downloads 271
4231 Towards an Adornian Critical Theory of the Environment

Authors: Dominic Roulx

Abstract:

Many scholars have in the past decade emphasized the relevance of Adorno’s criticism of the rationalized domination of nature (Naturbeherrschung) for thinking the environmental crisis. Beyond the intersubjective critical models of thinkers such as Habermas and Honneth, Adorno’s critical theory has the benefit, according to them, of disclosing the entwinement of social and natural domination in a critically productive way. The author will be arguing in this paper that Adorno’s model of critical theory displays a theoretical framework that is both original and relevant for thinking the ins and outs of the currentenvironmental crisis. To do so, he first construe Adorno’s understanding of the historical domination of nature and argue that Adorno’s method for its criticizing is immanent critique. He puts emphasis on how his understanding of the domination of nature implicitly implies an account of thedialectical relationship between reason and nature. In doing so, he presents a naturalistic understanding of his idea of the primacy of the object. Second, regarding Adorno’s concept of nature, he discusses what he sees as the shortcomings of many commentators’ understanding of the concept of nature in Adorno. He contends that they tend to fall short of Adorno’s concept of nature in failing to make sense of its thoroughly negative signification, thereby falling into an uncritical and fetichized comprehension of “nature. Third, he discusses the prospect for a possible “reconciliation” (Versöhnung) of nature with society. Highlighting how the domination of nature proves to produce the necessary conditions for its own overcoming, he contends that reconciliation with nature relies mainly on the subject’s capacity for critical self-reflection.

Keywords: german philosophy, adorno, nature, environmental crisis

Procedia PDF Downloads 58
4230 Numerical Simulation of the Fractional Flow Reserve in the Coronary Artery with Serial Stenoses of Varying Configuration

Authors: Mariia Timofeeva, Andrew Ooi, Eric K. W. Poon, Peter Barlis

Abstract:

Atherosclerotic plaque build-up, commonly known as stenosis, limits blood flow and hence oxygen and nutrient supplies to the heart muscle. Thus, assessment of its severity is of great interest to health professionals. Numerical simulation of the fractional flow reserve (FFR) has proved to be well correlated with invasively measured FFR used for physiological assessment of the severity of coronary stenosis in arteries. Atherosclerosis may impact the diseased artery in several locations causing serial stenoses, which is a complicated subset of coronary artery disease that requires careful treatment planning. However, hemodynamic of the serial sequential stenoses in coronary arteries has not been extensively studied. The hemodynamics of the serial stenoses is complex because the stenoses in the series interact and affect the flow through each other. To address this, serial stenoses in a 3.4 mm left anterior descending (LAD) artery are examined in this study. Two diameter stenoses (DS) are considered, 30 and 50 percent of the reference diameter. Serial stenoses configurations are divided into three groups based on the order of the stenoses in the series, spacing between them, and deviation of the stenoses’ symmetry (eccentricity). A patient-specific pulsatile waveform is used in the simulations. Blood flow within the stenotic artery is assumed to be laminar, Newtonian, and incompressible. Results for the FFR are reported. Based on the simulation results, it can be deduced that the larger drop in pressure (smaller value of the FFR) is expected when the percentage of the second stenosis in the series is bigger. Varying the distance between the stenoses affects the location of the maximum drop in the pressure, while the minimal FFR in the artery remains unchanged. Eccentric serial stenoses are characterized by a noticeably larger decrease in pressure through the stenoses and by the development of the chaotic flow downstream of the stenoses. The largest drop in the pressure (about 4% difference compared to the axisymmetric case) is obtained for the serial stenoses, where both the stenoses are highly eccentric with the centerlines deflected to the different sides of the LAD. In conclusion, varying configuration of the sequential serial stenoses results in a different distribution of FFR through the LAD. Results presented in this study provide insight into the clinical assessment of the severity of the coronary serial stenoses, which is proved to depend on the relative position of the stenoses and the deviation of the stenoses’ symmetry.

Keywords: computational fluid dynamics, coronary artery, fractional flow reserve, serial stenoses

Procedia PDF Downloads 158
4229 Women's Contemporary Dystopias: Feminist Protagonists Taking Back Control

Authors: Natalia Fontes De Oliveira

Abstract:

The Canadian author Margaret Atwood deconstructs the tainted dichotomies between women and men by embracing the disorder throughout her dystopias. In Atwood’s The Testaments, nature can be seen as a background to the story as well as a metaphorical expression of the characters’ state of mind, nevertheless, the protagonists’ nature writing portrays conveys a curiosity to the pre-established sanctions of a docile garden, viewing nature as an autonomous entity, especially when they are away from the confinements of Gilead’s regime. The three narrating protagonists, Agnes, Aunt Lydia, and Nicole, use nature writing subversively as a form of rebellion. This paper investigates how the three protagonists narrate nature through an intimist point of view, with sensibility to observe the multiple relationships among humanity, nature, and the impositions of a theocratic ultra conservative patriarchal society.

Keywords: contemporary literature, dystopias, feminism, women’s writing

Procedia PDF Downloads 133
4228 Effects of the Fractional Order on Nanoparticles in Blood Flow through the Stenosed Artery

Authors: Mohammed Abdulhameed, Sagir M. Abdullahi

Abstract:

In this paper, based on the applications of nanoparticle, the blood flow along with nanoparticles through stenosed artery is studied. The blood is acted by periodic body acceleration, an oscillating pressure gradient and an external magnetic field. The mathematical formulation is based on Caputo-Fabrizio fractional derivative without singular kernel. The model of ordinary blood, corresponding to time-derivatives of integer order, is obtained as a limiting case. Analytical solutions of the blood velocity and temperature distribution are obtained by means of the Hankel and Laplace transforms. Effects of the order of Caputo-Fabrizio time-fractional derivatives and three different nanoparticles i.e. Fe3O4, TiO4 and Cu are studied. The results highlights that, models with fractional derivatives bring significant differences compared to the ordinary model. It is observed that the addition of Fe3O4 nanoparticle reduced the resistance impedance of the blood flow and temperature distribution through bell shape stenosed arteries as compared to TiO4 and Cu nanoparticles. On entering in the stenosed area, blood temperature increases slightly, but, increases considerably and reaches its maximum value in the stenosis throat. The shears stress has variation from a constant in the area without stenosis and higher in the layers located far to the longitudinal axis of the artery. This fact can be an important for some clinical applications in therapeutic procedures.

Keywords: nanoparticles, blood flow, stenosed artery, mathematical models

Procedia PDF Downloads 224