Search results for: retinal artery occlusion
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 460

Search results for: retinal artery occlusion

250 Endovascular Aneurysm Repair (Evar) with Endoanchors: For Tandem Aortic Abdominal Aneurysm (Aaa) with Hostile Neck & Proximal Penetrating Atherosclerotic Ulcer

Authors: Von Jerick Tenorio, Jonald Lucero, Marivic Vestal, Edwin Tiempo

Abstract:

In patients with hostile aortic neck anatomy, the risks of proximal seal complications and stent migration remain with EVAR despite improved endograft technology. This case report discusses how the technical challenges of the hostile neck anatomy, proximal penetrating atherosclerotic ulcer (PAU) and tortuous femoral access were addressed. The CT aortogram of a 63-year-old hypertensive and diabetic man with recurring abdominal discomfort revealed a fusiform infra-renal aneurysm measuring 8.8 cm in length and 5.7 cm in diameter. The proximal landing zone only has a 3 mm healthy neck with a conicity of > 10% and a thrombus of 4 mm thick. Proximal to the aneurysm is a PAU with a circumferential mural thrombus. The right femoral artery is tortuous with > 90o angulation. A 20% oversized Endurant II endograft and Aptus Heli-FX EndoAnchors were deployed as prophylaxis for type I endoleaks and endograft migration consequent to the conical neck and proximal aneurysm extension consequent to the PAU. A stiff Backup Meier guide wire facilitated the deployment of the endograft. Coil embolization of the right internal iliac artery was performed as prophylaxis for type II endoleaks. EndoAnchors can be used as an adjunct to EVAR as prophylaxis for proximal seal complications and stent migration in patients with hostile aortic aneurysm neck anatomy and concomitant proximal PAU.

Keywords: endoAnchors, endoleaks, EVAR, hostile neck

Procedia PDF Downloads 170
249 Effects of Valproate on Vascular Endothelial Growth Factor in the Retina Associated with Choroidal Neovascularization

Authors: Zhang Zhenzhen

Abstract:

Valproate (VPA) is commonly used in the treatment of bipolar disorder and epilepsy. The mechanism is complicated, including its ability to inhibit histone deacetylases (HDACs). Here, we show that VPA attenuated VEGF gene expression and the morphological changes in choroidal neovascularization (CNV) induced by photocoagulation in retina. C57BL/6 mice were injected subcutaneously at 300mg/kg twice daily with VPA before insult. Vascular endothelial growth factor (VEGF)-A and VEGF-B were examined in the eyes of VPA-treated mice and in human retinal pigment epithelial cell lines (ARPE-19) exposed to VPA. In addition, CNV was induced by photocoagulation in mice injected with VPA, and the volume of CNV was compared by fluorescence-labeled choroidal flat mount. Morphological changes were analyzed on stained histological sections. Western blot analysis was used to determine protein levels of VEGF-A and VEGF-B, and acetylation of histone H3 in each group. VPA injected intraperitoneally attenuated the VEGF-A and VEGF-B expression in the retina, accompanied by the hyperacetylation of retina tissue, indicating that VPA acts directly on retina tissues through acetylation to reduce the expression of VEGF. VPA also attenuated the VEGF-A mRNA expression in the retinal pigment epithelium showed by immunohistochemistry. Moreover, the administration of VPA significantly attenuated photocoagulation-induced CNV in mice. These results demonstrate that VPA attenuated VEGF production in retina associated with choroidal neovascularization possibly via the HDAC inhibition.

Keywords: retina, acetylation, chorodial neovascularization, vascular endothelial growth factor

Procedia PDF Downloads 169
248 Procedural Protocol for Dual Energy Computed Tomography (DECT) Inversion

Authors: Rezvan Ravanfar Haghighi, S. Chatterjee, Pratik Kumar, V. C. Vani, Priya Jagia, Sanjiv Sharma, Susama Rani Mandal, R. Lakshmy

Abstract:

The dual energy computed tomography (DECT) aims at noting the HU(V) values for the sample at two different voltages V=V1, V2 and thus obtain the electron densities (ρe) and effective atomic number (Zeff) of the substance. In the present paper, we aim to obtain a numerical algorithm by which (ρe, Zeff) can be obtained from the HU(100) and HU(140) data, where V=100, 140 kVp. The idea is to use this inversion method to characterize and distinguish between the lipid and fibrous coronary artery plaques.With the idea to develop the inversion algorithm for low Zeff materials, as is the case with non calcified coronary artery plaque, we prepare aqueous samples whose calculated values of (ρe, Zeff) lie in the range (2.65×1023≤ ρe≤ 3.64×1023 per cc ) and (6.80≤ Zeff ≤ 8.90). We fill the phantom with these known samples and experimentally determine HU(100) and HU(140) for the same pixels. Knowing that the HU(V) values are related to the attenuation coefficient of the system, we present an algorithm by which the (ρe, Zeff) is calibrated with respect to (HU(100), HU(140)). The calibration is done with a known set of 20 samples; its accuracy is checked with a different set of 23 known samples. We find that the calibration gives the ρe with an accuracy of ± 4% while Zeff is found within ±1% of the actual value, the confidence being 95%.In this inversion method (ρe, Zeff) of the scanned sample can be found by eliminating the effects of the CT machine and also by ensuring that the determination of the two unknowns (ρe, Zeff) does not interfere with each other. It is found that this algorithm can be used for prediction of chemical characteristic (ρe, Zeff) of unknown scanned materials with 95% confidence level, by inversion of the DECT data.

Keywords: chemical composition, dual-energy computed tomography, inversion algorithm

Procedia PDF Downloads 407
247 Targeting Matrix Metalloprotease-9 to Reduce Coronary Artery Manifestations of Kawasaki’s Disease

Authors: Mohammadjavad Sotoudeheian, Navid Farahmandian

Abstract:

Kawasaki disease (KD) is the primary cause of acquired pediatric heart disease as an acute vasculitis. In children with prolonged fever, rash, and inflammation of the mucosa KD must be considered as a clinical diagnosis. There is a persuasive suggestion of immune-mediated damage as the pathophysiologic cascade of KD. For example, the invasion of cytotoxic T-cells supports a viral etiology and the inflammasome of the innate immune system is a critical component in the vasculitis formation in KD. Animal models of KD propose the cytokine profiles, such as increased IL-1 and GM-CSF, which cause vascular damage. CRP and IFN-γ elevated expression and the upregulation of IL-6, and IL-10 production are also described in previous studies. Untreated KD is a critical risk factor for coronary artery diseases and myocardial infarction. Vascular damage may encompass amplified T-cell activity. SMAD3 is an essential molecule in down-regulating T-cells and increasing expression of FoxP3. It has a critical effect in the differentiation of regulatory T-cells. The discrepancy of regulatory T-cells and pro-inflammatory Th17 has been studied in acute coronary syndrome during KD. However in the coronary artery damaged lymphocytes and IgA plasma cells are seen at the lesion locations, the major immune cells in the coronary lesions are monocytes/macrophages and neutrophils. These cells secrete TNF-α, and activates matrix metalloprotease (MMP)-9, reducing the integrity of vessels and prompting patients to arise aneurysm. MMPs can break down the components of the extracellular matrix and assist immune cell movement. IVIG as an effective form of treatment clarified the role of the immune system, which may target pathogenic antigens and regulate cytokine production. Several reports have revealed that in the coronary arteries, high expression of MMP-9 in monocyte/macrophage results in pathologic cascades. Curcumin is a potent antioxidant and anti-inflammatory molecule. Curcumin decreases the production of reactive oxygen and nitrogen species and inhibits transcription factors like AP-1 and NF-κB. Curcumin also contains the characteristics of inhibitory effects on MMPs, especially MMP-9. The upregulation of MMP-9 is an important cellular response. Curcumin treatment caused a reverse effect and down-regulates MMP-9 gene expression which may fund the anti-inflammatory effect. Curcumin inhibits MMP-9 expression via PKC and AMPK-dependent pathways in Human monocytes cells. Elevated expression and activity of MMP-9 are correlated with advanced vascular lesions. AMPK controls lipid metabolism and oxidation, and protein synthesis. AMPK is also necessary for the MMP-9 activity and THP-1 cell adhesion to endothelial cells. Curcumin was shown to inhibit the activation of AMPKα. Compound C (AMPK inhibitor) inhibits MMP-9 expression level. Therefore, through inactivating AMPKs and PKC, curcumin decreases the MMP-9 level, which results in inhibiting monocyte/macrophage differentiation. Compound C also suppress the phosphorylation of three major classes of MAP kinase signaling, suggesting that curcumin may suppress MMP-9 level by inactivation of MAPK pathways. MAPK cascades are activated to induce the expression of MMP-9. Curcumin inhibits MAPKs phosphorylation, which contributes to the down-regulation of MMP-9. This study demonstrated that the potential inhibitory properties of curcumin over MMP-9 lead to a therapeutic strategy to reduce the risk of coronary artery involvement during KD.

Keywords: MMP-9, coronary artery aneurysm, Kawasaki’s disease, curcumin, AMPK, immune system, NF-κB, MAPK

Procedia PDF Downloads 275
246 Adrenergic and Non-Adrenergic Control of Mesenteric Blood Vessels of Calves

Authors: A. Elmajdoub, A. El-Mahmoudy

Abstract:

The present study was designed to investigate the neurotransmitters that mediate the excitatory response of the circular muscle of final branches of mesenteric artery in bovine calves. Mesentery was dissected and the iliac branches were separated and used. The final mesenteric branches of diameter 400 micrometers and less responded strongly to norepinephrine and moderately to ATP. However, the mesenteric branches of wider diameters were gradually less responsive to norepinephrine and those of diameter 700 micrometers were exclusively nonresponsive. These arteries were strongly responsive to ATP (100 µM). Norepinephrine response was sensitive to phentolamine (3 µM) and prazosin (5 µM) indicating that it is mediated by α1 receptor; while ATP response was sensitive to suramin (200 µM), PPADS (50 µM), but not to cibacron blue (100 µM) indicating that it is mediated via P2X receptor. Further confirmatory experiments were performed including application of α1 and P2X receptor specific agonists which are methoxamine and α,β-methylene ATP. Methoxamine (1 µM) showed effects similar to norepinephrine in final branches and was without effect in wider branches. α,β-methylene ATP (1 µM), exhibited more pronounced effects on both wide and narrow branches but in parallel manner to that of ATP. Agonists for α2 and P2Y receptors as clonidine (10 µM) and 2-meThio ATP (10 µM), respectively, were without effect indicating that involvement of these receptors is unlikely. The neuropeptide-Y (200 nM) did not have any effects on either the narrow or the wide rings. Conclusion: These data may imply that in the most peripheral mesenteric arteries a strong vasopressor power represented by norepinephrine and ATP integration is needed for maintaining peripheral resistance; on the other hand a mild vasopressor power mediated only by ATP is enough to maintain the vascular tone in the relatively central mesenteric branches.

Keywords: ATP, calves, mesenteric artery, norepinephrine

Procedia PDF Downloads 284
245 Prenatal Development of Heart and Great Vessels in Buffalo (Bubalus bubalis)

Authors: Anuradha Gupta, Neelam Bansal, Varinder Uppal

Abstract:

The present investigation was made on 35 Indian buffalo fetuses ranging from 0.9 cm to 104 cm curved crown rump length (CVRL). The gross anatomical study revealed that all structures were developed at 13 cm CVRL (87 days) in group I. At 0.9 cm CVRL (32 days) the heart was unseptated and tubular and was clearly divided into common atrial chamber dorsally and primitive ventricle in 1.2 cm CVRL fetus (34 days). Septum primum appeared at 1.9 cm CVRL (37 days), truncal ridges at 2.5 cm CVRL (39 days) and foramen ovale in 3.0 cm CVRL (42 days) buffalo foetuses. At 7.6 cm CVRL (62 days) endocardial cushions fused to form left and right atrioventricular openings and four chambered heart was formed in 8.7 cm CVRL (66 days). Endocardium and epicardium was thicker in atria as compared to ventricles in all the age groups. Myocardium of atria was thin as compared to ventricles in all the age groups and was loosely arranged. Immature hyaline cartilage was first appeared at base of aorta in 62 cm CVRL (213 days) fetuses. Intercalated discs were seen in group III and aorta, pulmonary artery, coronary artery were well appreciated in 3.2 cm CVRL (43 days). Neutral and acid mucopolysaccharides were comparatively more in atria than ventricles. Basic proteins showed strong reaction in atrium and ventricle, and intense in conduction system. Lipids and phospholipids were more in myocardium and conduction system than endocardium and epicardium. All the histochemical moieties were comparatively more in tunica intima than media and adventitia of all the great vessels of heart.

Keywords: buffalo, fetal development, histochemistry, heart

Procedia PDF Downloads 241
244 Beating Heart Coronary Artery Bypass Grafting on Intermittent Pump Support

Authors: Sushil Kumar Singh, Vivek Tewarson, Sarvesh Kumar, Shobhit Kumar

Abstract:

Objective: ‘Beating Heart coronary artery bypass grafting on Intermittent Pump Support’ is a more reliable method of coronary revascularization that takes advantage of off and on-pump CABG while eliminating the disadvantage of both techniques. Methods: From January 2015 to December 2021, a new technique, “Intermittent On pump beating heart CABG” using a suction stabilizer was used by putting aortic and venous cannulas electively in all the patients. Patients were supported by a pump intermittently, as and when required (Group 1, n=254). Retrospective data were collected from our record of the patients who underwent off-pump CABG electively by the same surgeon and team (Group 2, n=254). Results: Significant advantage was noted in Group 1 patients in terms of the number of grafts (3.31 ± 1.16 vs. 2.30 ±0.66), grafting of lateral vessels (316 vs.202), mean operating time (1.37 ± 0.23 hrs vs. 2.22 ± 0.45 hrs) and postoperative blood loss (406.30 ± 257.90 ml vs. 567.41 ± 265.20 ml).CPB support time was less than 15 minutes in the majority of patients (n=179, 70.37 %), with a mean of 16.81 minutes. It was required, particularly during the grafting of lateral vessels. A rise in enzymes level (CRP, CKMB, Trop I, and NTPro BNP) was noted in Group 1 patients. But, these did not affect the postoperative course in patients. There was no mortality in Group 1 patients, while four patients in Group 2 died. Coclusions: Intermittent on-pump CABG technique is a promising method of surgical revascularization for all patients requiring CABG. It has shown its superiority in terms of safety, the number of grafts, operating time, and better perioperative course.

Keywords: cardiopulmonary bypass, CABG, beating heart CABG, on-pump CABG

Procedia PDF Downloads 87
243 Macular Ganglion Cell Inner Plexiform Layer Thinning

Authors: Hye-Young Shin, Chan Kee Park

Abstract:

Background: To compare the thinning patterns of the ganglion cell-inner plexiform layer (GCIPL) and peripapillary retinal nerve fiber layer (pRNFL) as measured using Cirrus high-definition optical coherence tomography (HD-OCT) in patients with visual field (VF) defects that respect the vertical meridian. Methods: Twenty eyes of eleven patients with VF defects that respect the vertical meridian were enrolled retrospectively. The thicknesses of the macular GCIPL and pRNFL were measured using Cirrus HD-OCT. The 5% and 1% thinning area index (TAI) was calculated as the proportion of abnormally thin sectors at the 5% and 1% probability level within the area corresponding to the affected VF. The 5% and 1% TAI were compared between the GCIPL and pRNFL measurements. Results: The color-coded GCIPL deviation map showed a characteristic vertical thinning pattern of the GCIPL, which is also seen in the VF of patients with brain lesions. The 5% and 1% TAI were significantly higher in the GCIPL measurements than in the pRNFL measurements (all P < 0.01). Conclusions: Macular GCIPL analysis clearly visualized a characteristic topographic pattern of retinal ganglion cell (RGC) loss in patients with VF defects that respect the vertical meridian, unlike pRNFL measurements. Macular GCIPL measurements provide more valuable information than pRNFL measurements for detecting the loss of RGCs in patients with retrograde degeneration of the optic nerve fibers.

Keywords: brain lesion, macular ganglion cell, inner plexiform layer, spectral-domain optical coherence tomography

Procedia PDF Downloads 313
242 Apolipoprotein A1 -75 G to a Substitution and Its Relationship with Serum ApoA1 Levels among Indian Punjabi Population

Authors: Savjot Kaur, Mridula Mahajan, AJS Bhanwer, Santokh Singh, Kawaljit Matharoo

Abstract:

Background: Disorders of lipid metabolism and genetic predisposition are CAD risk factors. ApoA1 is the apolipoprotein component of anti-atherogenic high density lipoprotein (HDL) particles. The protective action of HDL and ApoA1 is attributed to their central role in reverse cholesterol transport (RCT). Aim: This study was aimed at identifying sequence variations in ApoA1 (-75G>A) and its association with serum ApoA1 levels. Methods: A total of 300 CAD patients and 300 Normal individuals (controls) were analyzed. PCR-RFLP method was used to determine the DNA polymorphism in the ApoA1 gene, PCR products digested with restriction enzyme MspI, followed by Agarose Gel Electrophoresis. Serum apolipoprotein A1 concentration was estimated with immunoturbidimetric method. Results: Deviation from Hardy- Weinberg Equilibrium (HWE) was observed for this gene variant. The A- allele frequency was higher among Coronary Artery disease patients (53.8) compared to controls (45.5), p= 0.004, O.R= 1.38(1.11-1.75). Under recessive model analysis (AA vs. GG+GA) AA genotype of ApoA1 G>A substitution conferred ~1 fold increased risk towards CAD susceptibility (p= 0.002, OR= 1.72(1.2-2.43). With serum ApoA1 levels < 107 A allele frequency was higher among CAD cases (50) as compared to controls (43.4) [p=0.23, OR= 1.2(0.84-2)] and there was zero % occurrence of A allele frequency in individuals with ApoA1 levels > 177. Conclusion: Serum ApoA1 levels were associated with ApoA1 promoter region variation and influence CAD risk. The individuals with the APOA1 -75 A allele confer excess hazard of developing CAD as a result of its effect on low serum concentrations of ApoA1.

Keywords: apolipoprotein A1 (G>A) gene polymorphism, coronary artery disease (CAD), reverse cholesterol transport (RCT)

Procedia PDF Downloads 289
241 Categorical Metadata Encoding Schemes for Arteriovenous Fistula Blood Flow Sound Classification: Scaling Numerical Representations Leads to Improved Performance

Authors: George Zhou, Yunchan Chen, Candace Chien

Abstract:

Kidney replacement therapy is the current standard of care for end-stage renal diseases. In-center or home hemodialysis remains an integral component of the therapeutic regimen. Arteriovenous fistulas (AVF) make up the vascular circuit through which blood is filtered and returned. Naturally, AVF patency determines whether adequate clearance and filtration can be achieved and directly influences clinical outcomes. Our aim was to build a deep learning model for automated AVF stenosis screening based on the sound of blood flow through the AVF. A total of 311 patients with AVF were enrolled in this study. Blood flow sounds were collected using a digital stethoscope. For each patient, blood flow sounds were collected at 6 different locations along the patient’s AVF. The 6 locations are artery, anastomosis, distal vein, middle vein, proximal vein, and venous arch. A total of 1866 sounds were collected. The blood flow sounds are labeled as “patent” (normal) or “stenotic” (abnormal). The labels are validated from concurrent ultrasound. Our dataset included 1527 “patent” and 339 “stenotic” sounds. We show that blood flow sounds vary significantly along the AVF. For example, the blood flow sound is loudest at the anastomosis site and softest at the cephalic arch. Contextualizing the sound with location metadata significantly improves classification performance. How to encode and incorporate categorical metadata is an active area of research1. Herein, we study ordinal (i.e., integer) encoding schemes. The numerical representation is concatenated to the flattened feature vector. We train a vision transformer (ViT) on spectrogram image representations of the sound and demonstrate that using scalar multiples of our integer encodings improves classification performance. Models are evaluated using a 10-fold cross-validation procedure. The baseline performance of our ViT without any location metadata achieves an AuROC and AuPRC of 0.68 ± 0.05 and 0.28 ± 0.09, respectively. Using the following encodings of Artery:0; Arch: 1; Proximal: 2; Middle: 3; Distal 4: Anastomosis: 5, the ViT achieves an AuROC and AuPRC of 0.69 ± 0.06 and 0.30 ± 0.10, respectively. Using the following encodings of Artery:0; Arch: 10; Proximal: 20; Middle: 30; Distal 40: Anastomosis: 50, the ViT achieves an AuROC and AuPRC of 0.74 ± 0.06 and 0.38 ± 0.10, respectively. Using the following encodings of Artery:0; Arch: 100; Proximal: 200; Middle: 300; Distal 400: Anastomosis: 500, the ViT achieves an AuROC and AuPRC of 0.78 ± 0.06 and 0.43 ± 0.11. respectively. Interestingly, we see that using increasing scalar multiples of our integer encoding scheme (i.e., encoding “venous arch” as 1,10,100) results in progressively improved performance. In theory, the integer values do not matter since we are optimizing the same loss function; the model can learn to increase or decrease the weights associated with location encodings and converge on the same solution. However, in the setting of limited data and computation resources, increasing the importance at initialization either leads to faster convergence or helps the model escape a local minimum.

Keywords: arteriovenous fistula, blood flow sounds, metadata encoding, deep learning

Procedia PDF Downloads 54
240 Three Dimensional Large Eddy Simulation of Blood Flow and Deformation in an Elastic Constricted Artery

Authors: Xi Gu, Guan Heng Yeoh, Victoria Timchenko

Abstract:

In the current work, a three-dimensional geometry of a 75% stenosed blood vessel is analysed. Large eddy simulation (LES) with the help of a dynamic subgrid scale Smagorinsky model is applied to model the turbulent pulsatile flow. The geometry, the transmural pressure and the properties of the blood and the elastic boundary were based on clinical measurement data. For the flexible wall model, a thin solid region is constructed around the 75% stenosed blood vessel. The deformation of this solid region was modelled as a deforming boundary to reduce the computational cost of the solid model. Fluid-structure interaction is realised via a two-way coupling between the blood flow modelled via LES and the deforming vessel. The information of the flow pressure and the wall motion was exchanged continually during the cycle by an arbitrary lagrangian-eulerian method. The boundary condition of current time step depended on previous solutions. The fluctuation of the velocity in the post-stenotic region was analysed in the study. The axial velocity at normalised position Z=0.5 shows a negative value near the vessel wall. The displacement of the elastic boundary was concerned in this study. In particular, the wall displacement at the systole and the diastole were compared. The negative displacement at the stenosis indicates a collapse at the maximum velocity and the deceleration phase.

Keywords: Large Eddy Simulation, Fluid Structural Interaction, constricted artery, Computational Fluid Dynamics

Procedia PDF Downloads 267
239 The Use of Orthodontic Pacifiers to Prevent Pacifier Induced Malocclusion - A Literature Review

Authors: Maliha Ahmed Suleman, Sidra Ahmed Suleman

Abstract:

Introduction: The use of pacifiers is common amongst infants and young children as a comforting behavior. These non-nutritive sucking habits can be detrimental to the developing occlusion should they persist while the permanent dentition is established. Orthodontic pacifiers have been recommended as an alternative to conventional pacifiers as they are considered to have less interference with orofacial development. However, there is a lack of consensus on whether this is true. Aim and objectives: To review the prevalence of malocclusion associated with the use of orthodontic pacifiers. Methodology: Literature was identified through a rigorous search of the Embase, Pubmed, CINAHL, and Cochrane Library databases. Articles published from 2000 onwards were included. In total, 5 suitable papers were identified. Results: One study showed that the use of orthodontic pacifiers increased the risk of malocclusion, as seen through a greater prevalence of accentuated overjet, posterior crossbites, and anterior open bites in comparison to individuals who did not use pacifiers. However, this study found that there was a clinically significant reduction in the prevalence of anterior open bites amongst orthodontic pacifier users in comparison to conventional pacifier users. Another study found that both types of pacifiers lead to malocclusion; however, they found no difference in the mean overjet and prevalence of anterior open bites amongst conventional and orthodontic pacifier users. In contrast, one study suggested that orthodontic pacifiers do not seem to be related to the development of malocclusions in the primary dentitions, and using them between the ages of 0-3 months was actually beneficial as it prevents thumb-sucking habits. One of the systemic reviews concluded that orthodontic pacifiers do not seem to reduce the occurrence of posterior crossbites; however, they could reduce the development of open bites by virtue of their thin neck design. Whereas another systematic review concluded that there were no differences as to the effects on the stomatognathic system when comparing conventional and orthodontic pacifiers. Conclusion: There is limited and conflicting evidence to support the notion that orthodontic pacifiers can reduce the prevalence of malocclusion when compared to conventional pacifiers. Well-designed randomized controlled trials are required in the future in order to thoroughly assess the effects of orthodontic pacifiers on the developing occlusion and orofacial structures.

Keywords: orthodontics, pacifier, malocclusion, review

Procedia PDF Downloads 49
238 Ulnar Parametacarpal Flap for Coverage of Fifth Finger Defects: Propeller Flap Concept

Authors: Ahmed M. Gad, Ahmed S. Hweidi

Abstract:

Background: Defects of the little finger and adjacent areas are not uncommon. It could be a traumatic, post-burn, or after contracture release. Different options could be used for resurfacing these defect, including skin grafts, local or regional flaps. Ulnar para-metacarpal flap described by Bakhach in 1995 based on the distal division of the dorsal branch of the ulnar artery considered a good option for that. In this work, we applied the concept of propeller flap for better mobilization and in-setting of the ulnar para-metacarpal flap. Methods: The study included 15 cases with 4 females and 11 male patients. 10 of the patients had severe post-burn contractures of little finger, and 5 had post-traumatic little finger defects. Contractures were released and resulting soft tissue defects were reconstructed with propeller ulnar para-metacarpal artery flap. The flap based on two main perforators communicating with the palmar system, it was raised based on one of them depending on the extent of the defect and rotated 180 degrees after judicious dissection of the perforator. Results: 13 flaps survived completely, one of the cases developed partial skin loss, which healed by dressing, another flap was completely lost and covered later by a full-thickness skin graft. Conclusion: Ulnar para-metacarpal flap is a reliable option to resurface the little finger as well as adjacent areas. The application of the propeller flap concept based on whether the proximal or distal communicating branch makes the rotation and in-setting of the flap easier.

Keywords: little finger defects, propeller flap, regional hand defects, ulnar parametacarpal flap

Procedia PDF Downloads 158
237 A Case of Survival with Self-Draining Haemopericardium Secondary to Stabbing

Authors: Balakrishna Valluru, Ruth Suckling

Abstract:

A 16 year old male was found collapsed on the road following stab injuries to the chest and abdomen and was transported to the emergency department by ambulance. On arrival in the emergency department the patient was breathless and appeared pale. He was maintaining his airway with spontaneous breathing and had a heart rate of 122 beats per minute with a blood pressure of 83/63 mmHg. He was resuscitated initially with three units of packed red cells. Clinical examination identified three incisional wounds each measuring 2 cm. These were in the left para-sternal region, right infra-scapular region and left upper quadrant of the abdomen. The chest wound over the left parasternal area at the level of 4tth intercostal space was bleeding intermittently on leaning forwards and was relieving his breathlessness intermittently. CT imaging was performed to characterize his injuries and determine his management. CT scan of chest and abdomen showed moderate size haemopericardium with left sided haemopneumothorax. The patient underwent urgent surgical repair of the left ventricle and left anterior descending artery. He recovered without complications and was discharged from the hospital. This case highlights the fact that the potential to develop a life threatening cardiac tamponade was mitigated by the left parasternal stab wound. This injury fortuitously provided a pericardial window through which the bleeding from the injured left ventricle and left anterior descending artery could drain into the left hemithorax providing an opportunity for timely surgical intervention to repair the cardiac injuries.

Keywords: stab, incisional, haemo-pericardium, haemo-pneumothorax

Procedia PDF Downloads 177
236 The Clinical Use of Ahmed Valve Implant as an Aqueous Shunt for Control of Uveitic Glaucoma in Dogs

Authors: Khaled M. Ali, M. A. Abdel-Hamid, Ayman A. Mostafa

Abstract:

Objective: Safety and efficacy of Ahmed glaucoma valve implantation for the management of uveitis induced glaucoma evaluated on the five dogs with uncontrollable glaucoma. Materials and Methods: Ahmed Glaucoma Valve (AGV®; New World Medical, Rancho Cucamonga, CA, USA) is a flow restrictive, non-obstructive self-regulating valve system. Preoperative ocular evaluation included direct ophthalmoscopy and measurement of the intraocular pressure (IOP). The implant was examined and primed prior to implantation. The selected site of the valve implantation was the superior quadrant between the superior and lateral rectus muscles. A fornix-based incision was made through the conjunectiva and Tenon’s capsule. A pocket is formed by blunt dissection of Tenon’s capsule from the episclera. The body of the implant was inserted into the pocket with the leading edge of the device around 8-10 mm from the limbus. Results: No post operative complications were detected in the operated eyes except a persistent corneal edema occupied the upper half of the cornea in one case. Hyphaema was very mild and seen only in two cases which resolved quickly two days after surgery. Endoscopical evaluation for the operated eyes revealed a normal ocular fundus with clearly visible optic papilla, tapetum and retinal blood vessels. No evidence of hemorrhage, infection, adhesions or retinal abnormalities was detected. Conclusion: Ahmed glaucoma valve is safe and effective implant for treatment of uveitic glaucoma in dogs.

Keywords: Ahmed valve, endoscopy, glaucoma, ocular fundus

Procedia PDF Downloads 543
235 Predictors of Pericardial Effusion Requiring Drainage Following Coronary Artery Bypass Graft Surgery: A Retrospective Analysis

Authors: Nicholas McNamara, John Brookes, Michael Williams, Manish Mathew, Elizabeth Brookes, Tristan Yan, Paul Bannon

Abstract:

Objective: Pericardial effusions are an uncommon but potentially fatal complication after cardiac surgery. The goal of this study was to describe the incidence and risk factors associated with the development of pericardial effusion requiring drainage after coronary artery bypass graft surgery (CABG). Methods: A retrospective analysis was undertaken using prospectively collected data. All adult patients who underwent CABG at our institution between 1st January 2017 and 31st December 2018 were included. Pericardial effusion was diagnosed using transthoracic echocardiography (TTE) performed for clinical suspicion of pre-tamponade or tamponade. Drainage was undertaken if considered clinically necessary and performed via a sub-xiphoid incision, pericardiocentesis, or via re-sternotomy at the discretion of the treating surgeon. Patient demographics, operative characteristics, anticoagulant exposure, and postoperative outcomes were examined to identify those variables associated with the development of pericardial effusion requiring drainage. Tests of association were performed using the Fischer exact test for dichotomous variables and the Student t-test for continuous variables. Logistic regression models were used to determine univariate predictors of pericardial effusion requiring drainage. Results: Between January 1st, 2017, and December 31st, 2018, a total of 408 patients underwent CABG at our institution, and eight (1.9%) required drainage of pericardial effusion. There was no difference in age, gender, or the proportion of patients on preoperative therapeutic heparin between the study and control groups. Univariate analysis identified preoperative atrial arrhythmia (37.5% vs 8.8%, p = 0.03), reduced left ventricular ejection fraction (47% vs 56%, p = 0.04), longer cardiopulmonary bypass (130 vs 84 min, p < 0.01) and cross-clamp (107 vs 62 min, p < 0.01) times, higher drain output in the first four postoperative hours (420 vs 213 mL, p <0.01), postoperative atrial fibrillation (100% vs 32%, p < 0.01), and pleural effusion requiring drainage (87.5% vs 12.5%, p < 0.01) to be associated with development of pericardial effusion requiring drainage. Conclusion: In this study, the incidence of pericardial effusion requiring drainage was 1.9%. Several factors, mainly related to preoperative or postoperative arrhythmia, length of surgery, and pleural effusion requiring drainage, were identified to be associated with developing clinically significant pericardial effusions. High clinical suspicion and low threshold for transthoracic echo are pertinent to ensure this potentially lethal condition is not missed.

Keywords: coronary artery bypass, pericardial effusion, pericardiocentesis, tamponade, sub-xiphoid drainage

Procedia PDF Downloads 141
234 Comparative Outcomes of Percutaneous Coronary Intervention in Smokers versus Non Nonsmokers Patients: Observational Studies

Authors: Pratima Tatke, Archana Avhad, Bhanu Duggal, Meeta Rajivlochan, Sujata Saunik, Pradip Vyas, Nidhi Pandey, Aditee Dalvi, Jyothi Subramanian

Abstract:

Background: Smoking is well established risk factor for the development and progression of coronary artery disease. It is strongly related to morbidity and mortality from cardiovascular causes. The aim of this study is to observe effect of smoking status on percutaneous coronary intervention(PCI) after 1 year. Methods: 2527 patients who underwent PCI at different hospital of Maharashtra(India) from 2012 to 2015 under the health insurance scheme which is launched by Health department, Government of Maharashtra for below poverty line(BPL) families which covers cardiology. Informed consent of patients was taken .They were followed by telephonic survey after 6months to 1year of PCI . Outcomes of interest included myocardial infarction, restenosis, cardiac rehospitalization, death, and a composite of events after PCI. Made group of two non smokers-1861 and smokers (including patients who quit at time of PCI )-659. Results: Statistical Analysis using Pearson’s chi square test revealed that there was trend seen of increasing incidence of death, Myocardial infarction and Restenosis in smokers than non smokers .Smokers had a greater death risk compared to nonsmoker; 5.7% and 5.1% respectively p=0.518. Also Repeat procedures (2.1% vs. 1.5% p=0.222), breathlessness (17.8% vs. 18.20% p=0.1) and Myocardial Infarction (7.3% vs. 10%) high in smoker than non smokers. Conclusion: Major adverse cardiovascular events (MACE) were observed even after successful PCI in smokers. Patients undergoing percutaneous coronary intervention should be encouraged to stop smoking.

Keywords: coronary artery diseases, major adverse cardiovascular events, percutaneous coronary intervention, smoking

Procedia PDF Downloads 181
233 Effects of Handgrip Isometric Training in Blood Pressure of Patients with Peripheral Artery Disease

Authors: Raphael M. Ritti-Dias, Marilia A. Correia, Wagner J. R. Domingues, Aline C. Palmeira, Paulo Longano, Nelson Wolosker, Lauro C. Vianna, Gabriel G. Cucato

Abstract:

Patients with peripheral arterial disease (PAD) have a high prevalence of hypertension, which contributes to a high risk of acute cardiovascular events and cardiovascular mortality. Strategies to reduce cardiovascular risk of these patients are needed. Meta-analysis studies have shown that isometric handgrip training promotes reductions in clinical blood pressure in normotensive, pre-hypertensive and hypertensive individuals. However, the effect of this exercise training on other cardiovascular function indicators in PAD patients remains unknown. Thus, the aim of this study was to analyze the effects of isometric handgrip training on blood pressure in patients with PAD. In this clinical trial, 28 patients were randomly allocated into two groups: isometric handgrip training (HG) and control (CG). The HG conducted the unilateral handgrip training three days per week (four sets of two minutes, with 30% of maximum voluntary contraction with an interval of four minutes between sets). CG was encouraged to increase their physical activity levels. At baseline and after eight weeks blood pressure and heart rate were obtained. ANOVA two-way for repeated measures with the group (GH and GC) and time (pre- and post-intervention) as factors was performed. After 8 weeks of training there were no significant changes in systolic blood pressure (HG pre 141 ± 24.0 mmHg vs. HG post 142 ± 22.0 mmHg; CG pre 140 ± 22.1 mmHg vs. CG post 146 ± 16.2 mmHg; P=0.18), diastolic blood pressure (HG pre 74 ± 10.4 mmHg vs. HG post 74 ± 11.9 mmHg; CG pre 72 ± 6.9 mmHg vs. CG post 74 ± 8.0 mmHg; P=0.22) and heart rate (HG pre 61 ± 10.5 bpm vs. HG post 62 ± 8.0 bpm; CG pre 64 ± 11.8 bpm vs. CG post 65 ± 13.6 bpm; P=0.81). In conclusion, our preliminary data indicate that isometric handgrip training did not modify blood pressure and heart rate in patients with PAD.

Keywords: blood pressure, exercise, isometric, peripheral artery disease

Procedia PDF Downloads 309
232 Autophagy Promotes Vascular Smooth Muscle Cell Migration in vitro and in vivo

Authors: Changhan Ouyang, Zhonglin Xie

Abstract:

In response to proatherosclerotic factors such as oxidized lipids, or to therapeutic interventions such as angioplasty, stents, or bypass surgery, vascular smooth muscle cells (VSMCs) migrate from the media to the intima, resulting in intimal hyperplasia, restenosis, graft failure, or atherosclerosis. These proatherosclerotic factors also activate autophagy in VSMCs. However, the functional role of autophagy in vascular health and disease remains poorly understood. In the present study, we determined the role of autophagy in the regulation of VSMC migration. Autophagy activity in cultured human aortic smooth muscle cells (HASMCs) and mouse carotid arteries was measured by Western blot analysis of microtubule-associated protein 1 light chain 3 B (LC3B) and P62. The VSMC migration was determined by scratch wound assay and transwell migration assay. Ex vivo smooth muscle cell migration was determined using aortic ring assay. The in vivo SMC migration was examined by staining the carotid artery sections with smooth muscle alpha actin (alpha SMA) after carotid artery ligation. To examine the relationship between autophagy and neointimal hyperplasia, C57BL/6J mice were subjected to carotid artery ligation. Seven days after injury, protein levels of Atg5, Atg7, Beclin1, and LC3B drastically increased and remained higher in the injured arteries three weeks after the injury. In parallel with the activation of autophagy, vascular injury-induced neointimal hyperplasia as estimated by increased intima/media ratio. The en face staining of carotid artery showed that vascular injury enhanced alpha SMA staining in the intimal cells as compared with the sham operation. Treatment of HASMCs with platelet-derived growth factor (PDGF), one of the major factors for vascular remodeling in response to vascular injury, increased Atg7 and LC3 II protein levels and enhanced autophagosome formation. In addition, aortic ring assay demonstrated that PDGF treated aortic rings displayed an increase in neovessel formation compared with control rings. Whole mount staining for CD31 and alpha SMA in PDGF treated neovessels revealed that the neovessel structures were stained by alpha SMA but not CD31. In contrast, pharmacological and genetic suppression of autophagy inhibits VSMC migration. Especially, gene silencing of Atg7 inhibited VSMC migration induced by PDGF. Furthermore, three weeks after ligation, markedly decreased neointimal formation was found in mice treated with chloroquine, an inhibitor of autophagy. Quantitative morphometric analysis of the injured vessels revealed a marked reduction in the intima/media ratio in the mice treated with chloroquine. Conclusion: Autophagy activation increases VSMC migration while autophagy suppression inhibits VSMC migration. These findings suggest that autophagy suppression may be an important therapeutic strategy for atherosclerosis and intimal hyperplasia.

Keywords: autophagy, vascular smooth muscle cell, migration, neointimal formation

Procedia PDF Downloads 285
231 Endothelial Dysfunction in Non-Alcoholic Fatty Liver Disease: An Updated Meta-Analysis

Authors: Anit S. Malhotra, Ajay Duseja, Neelam Chadha

Abstract:

Endothelial dysfunction is a precursor to atherosclerosis, and flow-mediated dilatation (FMD) in the brachial artery is the commonest method to evaluate endothelial function in humans. Non-alcoholic fatty liver disease (NAFLD) is one of the most common liver disorders encountered in clinical practice. An earlier meta-analysis had quantitatively assessed the degree of endothelial dysfunction using FMD. However, the largest study investigating the relation of FMD with NAFLD was published after that meta-analysis. In addition, that meta-analysis did not include some studies, including one from our centre. Therefore, an updating the previous meta-analysis was considered important. We searched PubMed, Cochrane Library, Embase, Scopus, SCI, Google Scholar, conference proceedings, and references of included studies till June 2017 to identify observational studies evaluating endothelial function using FMD in patients with non-alcoholic fatty liver disease. Data was analyzed using MedCalc. Fourteen studies were found eligible for inclusion in the meta-analysis. Patients with NAFLD had lower brachial artery FMD as compared to controls, standardized mean difference (random effects model) being –1.279%; 95% confidence interval (CI), –1.478 to –0.914. The effect size became smaller after addition of the recent study with the largest sample size was included compared with the earlier meta-analysis. In conclusion, patients with NAFLD had low FMD values indicating that they are at a higher risk of cardiovascular disease although our results suggest the effect size is not as large as reported previously.

Keywords: endothelial dysfunction, flow-mediated dilatation, meta-analysis, non-alcoholic fatty liver disease

Procedia PDF Downloads 175
230 CFD Analysis of the Blood Flow in Left Coronary Bifurcation with Variable Angulation

Authors: Midiya Khademi, Ali Nikoo, Shabnam Rahimnezhad Baghche Jooghi

Abstract:

Cardiovascular diseases (CVDs) are the main cause of death globally. Most CVDs can be prevented by avoiding habitual risk factors. Separate from the habitual risk factors, there are some inherent factors in each individual that can increase the risk potential of CVDs. Vessel shapes and geometry are influential factors, having great impact on the blood flow and the hemodynamic behavior of the vessels. In the present study, the influence of bifurcation angle on blood flow characteristics is studied. In order to approach this topic, by simplifying the details of the bifurcation, three models with angles 30°, 45°, and 60° were created, then by using CFD analysis, the response of these models for stable flow and pulsatile flow was studied. In the conducted simulation in order to eliminate the influence of other geometrical factors, only the angle of the bifurcation was changed and other parameters remained constant during the research. Simulations are conducted under dynamic and stable condition. In the stable flow simulation, a steady velocity of 0.17 m/s at the inlet plug was maintained and in dynamic simulations, a typical LAD flow waveform is implemented. The results show that the bifurcation angle has an influence on the maximum speed of the flow. In the stable flow condition, increasing the angle lead to decrease the maximum flow velocity. In the dynamic flow simulations, increasing the bifurcation angle lead to an increase in the maximum velocity. Since blood flow has pulsatile characteristics, using a uniform velocity during the simulations can lead to a discrepancy between the actual results and the calculated results.

Keywords: coronary artery, cardiovascular disease, bifurcation, atherosclerosis, CFD, artery wall shear stress

Procedia PDF Downloads 137
229 Mathematical Modelling of Blood Flow with Magnetic Nanoparticles as Carrier for Targeted Drug Delivery in a Stenosed Artery

Authors: Sreeparna Majee, G. C. Shit

Abstract:

A study on targeted drug delivery is carried out in an unsteady flow of blood infused with magnetic NPs (nanoparticles) with an aim to understand the flow pattern and nanoparticle aggregation in a diseased arterial segment having stenosis. The magnetic NPs are supervised by the magnetic field which is significant for therapeutic treatment of arterial diseases, tumor and cancer cells and removing blood clots. Coupled thermal energy have also been analyzed by considering dissipation of energy because of the application of the magnetic field and the viscosity of blood. Simulation technique used to solve the mathematical model is vorticity-stream function formulations in the diseased artery. An elevation in SLP (Specific loss power) is noted in the aortic bloodstream when the agglomeration of nanoparticles is higher. This phenomenon has potential application in the treatment of hyperthermia. The study focuses on the lowering of WSS (Wall Shear Stress) with increasing particle concentration at the downstream of the stenosis which depicts the vigorous flow circulation zone. These low shear stress regions prolong the residing time of the nanoparticles carrying drugs which soaks up the LDL (Low Density Lipoprotein) deposition. Moreover, an increase in NP concentration enhances the Nusselt number which marks the increase of heat transfer from the arterial wall to the surrounding tissues to destroy tumor and cancer cells without affecting the healthy cells. The results have a significant influence in the study of medicine, to treat arterial diseases such as atherosclerosis without the need for surgery which can minimize the expenditures on cardiovascular treatments.

Keywords: magnetic nanoparticles, blood flow, atherosclerosis, hyperthermia

Procedia PDF Downloads 111
228 First-Trimester Screening of Preeclampsia in a Routine Care

Authors: Tamar Grdzelishvili, Zaza Sinauridze

Abstract:

Introduction: Preeclampsia is a complication of the second trimester of pregnancy, which is characterized by high morbidity and multiorgan damage. Many complex pathogenic mechanisms are now implicated to be responsible for this disease (1). Preeclampsia is one of the leading causes of maternal mortality worldwide. Statistics are enough to convince you of the seriousness of this pathology: about 100,000 women die of preeclampsia every year. It occurs in 3-14% (varies significantly depending on racial origin or ethnicity and geographical region) of pregnant women, in 75% of cases - in a mild form, and in 25% - in a severe form. During severe pre-eclampsia-eclampsia, perinatal mortality increases by 5 times and stillbirth by 9.6 times. Considering that the only way to treat the disease is to end the pregnancy, the main thing is timely diagnosis and prevention of the disease. Identification of high-risk pregnant women for PE and giving prophylaxis would reduce the incidence of preterm PE. First-trimester screening model developed by the Fetal Medicine Foundation (FMF), which uses the Bayes-theorem to combine maternal characteristics and medical history together with measurements of mean arterial pressure, uterine artery pulsatility index, and serum placental growth factor, has been proven to be effective and have superior screening performance to that of traditional risk factor-based approach for the prediction of PE (2) Methods: Retrospective single center screening study. The study population consisted of women from the Tbilisi maternity hospital “Pineo medical ecosystem” who met the following criteria: they spoke Georgian, English, or Russian and agreed to participate in the study after discussing informed consent and answering questions. Prior to the study, the informed consent forms approved by the Institutional Review Board were obtained from the study subjects. Early assessment of preeclampsia was performed between 11-13 weeks of pregnancy. The following were evaluated: anamnesis, dopplerography of the uterine artery, mean arterial blood pressure, and biochemical parameter: Pregnancy-associated plasma protein A (PAPP-A). Individual risk assessment was performed with performed by Fast Screen 3.0 software ThermoFisher scientific. Results: A total of 513 women were recruited and through the study, 51 women were diagnosed with preeclampsia (34.5% in the pregnant women with high risk, 6.5% in the pregnant women with low risk; P<0.000 1). Conclusions: First-trimester screening combining maternal factors with uterine artery Doppler, blood pressure, and pregnancy-associated plasma protein-A is useful to predict PE in a routine care setting. More patient studies are needed for final conclusions. The research is still ongoing.

Keywords: first-trimester, preeclampsia, screening, pregnancy-associated plasma protein

Procedia PDF Downloads 47
227 Assessment of Arterial Stiffness through Measurement of Magnetic Flux Disturbance and Electrocardiogram Signal

Authors: Jing Niu, Jun X. Wang

Abstract:

Arterial stiffness predicts mortality and morbidity, independently of other cardiovascular risk factors. And it is a major risk factor for age-related morbidity and mortality. The non-invasive industry gold standard measurement system of arterial stiffness utilizes pulse wave velocity method. However, the desktop device is expensive and requires trained professional to operate. The main objective of this research is the proof of concept of the proposed non-invasive method which uses measurement of magnetic flux disturbance and electrocardiogram (ECG) signal for measuring arterial stiffness. The method could enable accurate and easy self-assessment of arterial stiffness at home, and to help doctors in research, diagnostic and prescription in hospitals and clinics. A platform for assessing arterial stiffness through acquisition and analysis of radial artery pulse waveform and ECG signal has been developed based on the proposed method. Radial artery pulse waveform is acquired using the magnetic based sensing technology, while ECG signal is acquired using two dry contact single arm ECG electrodes. The measurement only requires the participant to wear a wrist strap and an arm band. Participants were recruited for data collection using both the developed platform and the industry gold standard system. The results from both systems underwent correlation assessment analysis. A strong positive correlation between the results of the two systems is observed. This study presents the possibility of developing an accurate, easy to use and affordable measurement device for arterial stiffness assessment.

Keywords: arterial stiffness, electrocardiogram, pulse wave velocity, Magnetic Flux Disturbance

Procedia PDF Downloads 161
226 Finite Element Analysis of the Anaconda Device: Efficiently Predicting the Location and Shape of a Deployed Stent

Authors: Faidon Kyriakou, William Dempster, David Nash

Abstract:

Abdominal Aortic Aneurysm (AAA) is a major life-threatening pathology for which modern approaches reduce the need for open surgery through the use of stenting. The success of stenting though is sometimes jeopardized by the final position of the stent graft inside the human artery which may result in migration, endoleaks or blood flow occlusion. Herein, a finite element (FE) model of the commercial medical device AnacondaTM (Vascutek, Terumo) has been developed and validated in order to create a numerical tool able to provide useful clinical insight before the surgical procedure takes place. The AnacondaTM device consists of a series of NiTi rings sewn onto woven polyester fabric, a structure that despite its column stiffness is flexible enough to be used in very tortuous geometries. For the purposes of this study, a FE model of the device was built in Abaqus® (version 6.13-2) with the combination of beam, shell and surface elements; the choice of these building blocks was made to keep the computational cost to a minimum. The validation of the numerical model was performed by comparing the deployed position of a full stent graft device inside a constructed AAA with a duplicate set-up in Abaqus®. Specifically, an AAA geometry was built in CAD software and included regions of both high and low tortuosity. Subsequently, the CAD model was 3D printed into a transparent aneurysm, and a stent was deployed in the lab following the steps of the clinical procedure. Images on the frontal and sagittal planes of the experiment allowed the comparison with the results of the numerical model. By overlapping the experimental and computational images, the mean and maximum distances between the rings of the two models were measured in the longitudinal, and the transverse direction and, a 5mm upper bound was set as a limit commonly used by clinicians when working with simulations. The two models showed very good agreement of their spatial positioning, especially in the less tortuous regions. As a result, and despite the inherent uncertainties of a surgical procedure, the FE model allows confidence that the final position of the stent graft, when deployed in vivo, can also be predicted with significant accuracy. Moreover, the numerical model run in just a few hours, an encouraging result for applications in the clinical routine. In conclusion, the efficient modelling of a complicated structure which combines thin scaffolding and fabric has been demonstrated to be feasible. Furthermore, the prediction capabilities of the location of each stent ring, as well as the global shape of the graft, has been shown. This can allow surgeons to better plan their procedures and medical device manufacturers to optimize their designs. The current model can further be used as a starting point for patient specific CFD analysis.

Keywords: AAA, efficiency, finite element analysis, stent deployment

Procedia PDF Downloads 167
225 Comparative Evaluation of Ultrasound Guided Internal Jugular Vein Cannulation Using Measured Guided Needle and Conventional Size Needle for Success and Complication of Cannulation

Authors: Devendra Gupta, Vikash Arya, Prabhat K. Singh

Abstract:

Background: Ultrasound guidance could be beneficial in placing central venous catheters by improving the success rate, reducing the number of needle passes, and decreasing complications. Central venous cannulation set has a single puncture needle of a fixed length of 6.4 cm. However, the average distance of midpoint of IJV to the skin is around 1 cm to 2 cm. The long length needle has tendency to go in depth more than required and this is very common during learning period of any individual. Therefore, we devised a long needle with a guard which can be adjusted according to the required length. Methods: After approval from the institute ethics committee and patient’s written informed consent, a prospective, randomized, single-blinded controlled study was conducted. Adult patient aged of both sexes with ASA grade 1-2 undergoing surgery requiring internal jugular venous (IJV) access was included. After intubation, the head was rotated to the contralateral side at 30 degree head rotation on the position of the right IJV. The transducer probe a 6.5 to 13-MHz linear transducer (Sonosite, USA) had been placed at the apex of triangle with minimal pressure to avoid IJV compression. The distance from skin to midpoint of the right IJV and skin to anterior wall of Common Carotid Artery (CCA) had been done using B-mode duplex sonography with a 6.5 to 13-MHz linear transducer. Depending upon the results of randomization 420 patients had been divided into two groups of equal numbers (n=210). Group 1. USG guided right sided IJV cannulation was done with conventional (6.4 cm) needle; and Group 2. USG guided right sided IJV cannulation was done with conventional (6.4 cm) needle with guard fixed to a required length (length between skin and midpoint of IJV) by an experienced anesthesiologist. Independent observer has noted the number of attempts and occurrence of complications (CCA puncture, pneumothorax or adjacent tissue damage). Results: Demographic data were similar in both the group. The groups were comparable when considered for relationship of IJV to CCA. There was no significant difference between groups as regard to distance of midpoint of IJV to the skin (p<0.05). IJV cannulation was successfully done in single attempts in 180 (85.7%), in two attempts in 27 (12.9%) and three attempts in 3 (1.4%) in group I, whereas in single attempt in 207 (98.6%) and second attempts in 3 (1.4%) in group II (p <0.000). Incidence of carotid artery puncture was significantly more in group I (7.1%) compared to group II (0%) (p<0.000). Incidence of adjacent tissue puncture was significantly more in group I (8.6%) compared to group II (0%) (p<0.000). Conclusion: Therefore IJV catheterization using guard over the needle at predefined length with the help of real-time ultrasound results in better success rates and lower immediate complications.

Keywords: ultrasound guided, internal jugular vein cannulation, measured guided needle, common carotid artery puncture

Procedia PDF Downloads 186
224 Sudden Death in Young Patients: A Study of 312 Autopsy Cases

Authors: N. Haj Salem, M. Belhadj, S. Ben Jomâa, S. Saadi, R. Dhouieb, A. Chadly

Abstract:

Introduction: Sudden death in young is seen as a dramatic phenomenon requiring knowledge of its impact and determining their causes. Aim: We aim to study the epidemiological characteristics of sudden death in young, and to discuss the mechanism and the importance of autopsy in these situations. Material and methods: We performed a retrospective cohort study using autopsy data from the department of forensic medicine at the University Hospital of Fattouma Bourguiba, Monastir-Tunisia. A review of all autopsies performed during 23 years was done. In each case, clinical information and circumstances of death were obtained. We have included all sudden death in persons aged between 1 year and 35 years for the male and from one year to 45 years for female. We collected 312 cases of sudden death during the studied period. The collected data were processed using SPSS 20. The significance level was set at 0.05. Results: Thirty-two cases of cardiac ischemic sudden death have been collected. Myocardial infarction was the second cause of sudden death in young patients. There was a male predominance. The most affected subjects were aged between 25-45 years. The death occurred more frequently at rest. Coronary artery disease has been discovered in twenty-four cases (75%). A severe coronary artery disease was observed in two children with medical history of familial hypercholesterolemia. The myocardial infarction occurred in healthy coronary arteries in eight cases. An anomalous course of coronary arteries, in particular, myocardial bridging, was found in eight cases (25%). Toxicological screening was negative in all cases. Second cause of death was hypertrophic cardiomyopathy. Neurological and respiratory causes of death were implicated respectively in 10% and 15%. Conclusion: Identifying epidemiological characteristics of sudden death in this population is important for guiding approaches to prevention that must be based on dietary hygienic measures and the control of cardiovascular risk factors.

Keywords: autopsy, cardiac death, sudden death, young

Procedia PDF Downloads 214
223 Impaired Transient Receptor Potential Vanilloid 4-Mediated Dilation of Mesenteric Arteries in Spontaneously Hypertensive Rats

Authors: Ammar Boudaka, Maryam Al-Suleimani, Hajar BaOmar, Intisar Al-Lawati, Fahad Zadjali

Abstract:

Background: Hypertension is increasingly becoming a matter of medical and public health importance. The maintenance of normal blood pressure requires a balance between cardiac output and total peripheral resistance. The endothelium, through the release of vasodilating factors, plays an important role in the control of total peripheral resistance and hence blood pressure homeostasis. Transient Receptor Potential Vanilloid type 4 (TRPV4) is a mechanosensitive non-selective cation channel that is expressed on the endothelium and contributes to endothelium-mediated vasodilation. So far, no data are available about the morphological and functional status of this channel in hypertensive cases. Objectives: This study aimed to investigate whether there is any difference in the morphological and functional features of TRPV4 in the mesenteric artery of normotensive and hypertensive rats. Methods: Functional feature of TRPV4 in four experimental animal groups: young and adult Wistar-Kyoto rats (WKY-Y and WKY-A), young and adult spontaneously hypertensive rats (SHR-Y and SHR-A), was studied by adding 5 µM 4αPDD (TRPV4 agonist) to mesenteric arteries mounted in a four-chamber wire myograph and pre-contracted with 4 µM phenylephrine. The 4αPDD-induced response was investigated in the presence and absence of 1 µM HC067047 (TRPV4 antagonist), 100 µM L-NAME (nitric oxide synthase inhibitor), and endothelium. The morphological distribution of TRPV4 in the wall of rat mesenteric arteries was investigated by immunostaining. Real-time PCR was used in order to investigate mRNA expression level of TRPV4 in the mesenteric arteries of the four groups. The collected data were expressed as mean ± S.E.M. with n equal to the number of animals used (one vessel was taken from each rat). To determine the level of significance, statistical comparisons were performed using the student’s t-test and considered to be significantly different at p<0.05. Results: 4αPDD induced a relaxation response in the mesenteric arterial preparations (WKY-Y: 85.98% ± 4.18; n = 5) that was markedly inhibited by HC067047 (18.30% ± 2.86; n= 5; p<0.05), endothelium removal (19.93% ± 1.50; n = 5; p<0.05) and L-NAME (28.18% ± 3.09; n = 5; p<0.05). The 4αPDD-induced relaxation was significantly lower in SHR-Y compared to WKY-Y (SHR-Y: 70.96% ± 3.65; n = 6, WKY-Y: 85.98% ± 4.18; n = 5-6, p<0.05. Moreover, the 4αPDD-induced response was significantly lower in WKY-A than WKY-Y (WKY-A: 75.58 ± 1.30; n = 5, WKY-Y: 85.98% ± 4.18; n = 5, p<0.05). Immunostaining study showed immunofluorescent signal confined to the endothelial layer of the mesenteric arteries. The expression of TRPV4 mRNA in SHR-Y was significantly lower than in WKY-Y (SHR-Y; 0.67RU ± 0.34; n = 4, WKY-Y: 2.34RU ± 0.15; n = 4, p<0.05). Furthermore, TRPV4 mRNA expression in WKY-A was lower than its expression in WKY-Y (WKY-A: 0.62RU ± 0.37; n = 4, WKY-Y: 2.34RU ± 0.15; n = 4, p<0.05). Conclusion: Stimulation of TRPV4, which is expressed on the endothelium of rat mesenteric artery, triggers an endothelium-mediated relaxation response that markedly decreases with hypertension and growing up changes due to downregulation of TRPV4 expression.

Keywords: hypertension, endothelium, mesenteric artery, TRPV4

Procedia PDF Downloads 284
222 An Assessment of Finite Element Computations in the Structural Analysis of Diverse Coronary Stent Types: Identifying Prerequisites for Advancement

Authors: Amir Reza Heydari, Yaser Jenab

Abstract:

Coronary artery disease, a common cardiovascular disease, is attributed to the accumulation of cholesterol-based plaques in the coronary arteries, leading to atherosclerosis. This disease is associated with risk factors such as smoking, hypertension, diabetes, and elevated cholesterol levels, contributing to severe clinical consequences, including acute coronary syndromes and myocardial infarction. Treatment approaches such as from lifestyle interventions to surgical procedures like percutaneous coronary intervention and coronary artery bypass surgery. These interventions often employ stents, including bare-metal stents (BMS), drug-eluting stents (DES), and bioresorbable vascular scaffolds (BVS), each with its advantages and limitations. Computational tools have emerged as critical in optimizing stent designs and assessing their performance. The aim of this study is to provide an overview of the computational methods of studies based on the finite element (FE) method in the field of coronary stenting and discuss the potential for development and clinical application of stent devices. Additionally, the importance of assessing the ability of computational models is emphasized to represent real-world phenomena, supported by recent guidelines from the American Society of Mechanical Engineers (ASME). Validation processes proposed include comparing model performance with in vivo, ex-vivo, or in vitro data, alongside uncertainty quantification and sensitivity analysis. These methods can enhance the credibility and reliability of in silico simulations, ultimately aiding in the assessment of coronary stent designs in various clinical contexts.

Keywords: atherosclerosis, materials, restenosis, review, validation

Procedia PDF Downloads 53
221 Cardiovascular Disease Is Common among Patients with Systemic Lupus Erythematosus

Authors: Fathia Ehmouda Zaid, Reim Abudelnbi

Abstract:

Cardiovascular disease is a major cause of morbidity and mortality in patients with systemic lupus erythematosus (SLE). Patients and method: Cross-section study (68) patients diagnosed as systemic lupus erythematosus (SLE), who visited the outpatient clinic of rheumatology, these patients were interviewed with a structured questionnaire about their past and current clinically for presence of Cardiovascular disease in systemic lupus and use SLEDAI, specific tests [ECG –ECHO –CXRAY] the data are analyzed statistically by Pearson's correlation coefficient was calculated and statistical significance was defined as P< 0.05,during period (2013-2014). Objective: Estimation Cardiovascular disease manifestation of systemic lupus erythematosus, correlation with disease activity, morbidity, and mortality. Result: (68) Patients diagnosed as systemic lupus erythematosus' age range from (18-48 years), M=(13±29Y), Sex were female 66/68 (97.1%), male 2/68 (2.9%),duration of disease range[1-15year], M =[7±8y], we found Cardiovascular disease manifestation of systemic lupus erythematosus 32/68 (47.1%), correlation with disease activity use SLEDAI,(r= 476** p=0.000),Morbidity,(r= .554**; p=0.000) and mortality (r=.181; p=.139), Cardiovascular disease manifestations of systemic lupus erythematosus are pericarditis 8/68 (11.8%), pericardial effusion 6/68 (8.8%), myocarditis 4/68 (5.9 %), valvular lesions (endocarditis) 1/68 (1.5%), pulmonary hypertension (PAH) 12/68 (17.6%), coronary artery disease 1/68 (1.5%), none of patients have conduction abnormalities involvement. Correlation with disease activity use SLEDAI, pericarditis (r= .210, p=.086), pericardial effusion (r= 0.079, p=.520), myocarditis (r= 272*, p=.027), valvular lesions (endocarditis) (r= .112, p= .362), pulmonary hypertension (PAH) (r= .257*, p=.035) and coronary artery disease (r=.075, p=.544) correlation between cardiovascular disease manifestations of systemic lupus erythematosus and specific organ involvement we found Mucocutaneous (r=.091 p= .459), musculoskeletal (MSK) (r=.110 p=.373), Renal disease (r=.278*, p=.022), neurologic disease (r=.085, p=.489) and Hematologic disease (r=-.264*, p=.030). Conclusion: Cardiovascular manifestation is more frequent symptoms with systemic lupus erythematosus (SLE) is 47 % correlation with disease activity and morbidity but not with mortality. Recommendations: Focus research to evaluation and an adequate assessment of cardiovascular complications on the morbidity and mortality of the patients with SLE are still required.

Keywords: cardiovascular disease, systemic lupus erythematosus, disease activity, mortality

Procedia PDF Downloads 415