Search results for: orofacial biomechanics
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 104

Search results for: orofacial biomechanics

74 Diffusion Magnetic Resonance Imaging and Magnetic Resonance Spectroscopy in Detecting Malignancy in Maxillofacial Lesions

Authors: Mohamed Khalifa Zayet, Salma Belal Eiid, Mushira Mohamed Dahaba

Abstract:

Introduction: Malignant tumors may not be easily detected by traditional radiographic techniques especially in an anatomically complex area like maxillofacial region. At the same time, the advent of biological functional MRI was a significant footstep in the diagnostic imaging field. Objective: The purpose of this study was to define the malignant metabolic profile of maxillofacial lesions using diffusion MRI and magnetic resonance spectroscopy, as adjunctive aids for diagnosing of such lesions. Subjects and Methods: Twenty-one patients with twenty-two lesions were enrolled in this study. Both morphological and functional MRI scans were performed, where T1, T2 weighted images, diffusion-weighted MRI with four apparent diffusion coefficient (ADC) maps were constructed for analysis, and magnetic resonance spectroscopy with qualitative and semi-quantitative analyses of choline and lactate peaks were applied. Then, all patients underwent incisional or excisional biopsies within two weeks from MR scans. Results: Statistical analysis revealed that not all the parameters had the same diagnostic performance, where lactate had the highest areas under the curve (AUC) of 0.9 and choline was the lowest with insignificant diagnostic value. The best cut-off value suggested for lactate was 0.125, where any lesion above this value is supposed to be malignant with 90 % sensitivity and 83.3 % specificity. Despite that ADC maps had comparable AUCs still, the statistical measure that had the final say was the interpretation of likelihood ratio. As expected, lactate again showed the best combination of positive and negative likelihood ratios, whereas for the maps, ADC map with 500 and 1000 b-values showed the best realistic combination of likelihood ratios, however, with lower sensitivity and specificity than lactate. Conclusion: Diffusion weighted imaging and magnetic resonance spectroscopy are state-of-art in the diagnostic arena and they manifested themselves as key players in the differentiation process of orofacial tumors. The complete biological profile of malignancy can be decoded as low ADC values, high choline and/or high lactate, whereas that of benign entities can be translated as high ADC values, low choline and no lactate.

Keywords: diffusion magnetic resonance imaging, magnetic resonance spectroscopy, malignant tumors, maxillofacial

Procedia PDF Downloads 147
73 Oncological and Antiresorptive Treatment of Breast Cancer: Dental Assessment and Risk of MRONJ Development

Authors: Magdalena Korytowska, Gunnar Lengstrand, Cecilia Larsson Wexell

Abstract:

Background: Breast cancer (BC) is the most common cancer among women worldwide, and cases are continuing to increase in Sweden. Bone is the most common metastatic site in breast cancer patients, where > 65-75% of women with advanced breast cancer develop bone metastases during their disease. To prevent the skeletal-related events of metastases (e.g., pathological fractures, bone loss, cancer-induced bone pain, and hypercalcemia bone), two different classes of antiresorptive medications (AR), bisphosphonate and denosumab are typically administered every 3 to 4 weeks. Since 2015, adjuvant bisphosphonate treatment has been used every six months for three to five years in postmenopausal women for the prevention of skeletal metastases and improved survival. Methods: A case-control study was conducted to test the hypotheses that patients treated with high-dose AR are at higher risk of developing MRONJ than breast cancer patients with adjuvant bisphosphonate treatment at a lower dose. Medical and odontological data was collected between 2015-2020. Assessment of oral health and dental care before and during oncological treatment took place at the specialist clinic for Orofacial medicine linked to the specific hospital. Results: In total, 220 patients were included, 101 patients in the high-dose group and 119 patients in the adjuvant BP-treatment group. MRONJ was diagnosed in 13 patients (14%) in the high-dose group. The mandible was affected in most of the cases (84.6%), with a mean duration of high-dose treatment of 19.7 months. In 46.2% of cases, no dental cause of MRONJ could be identified. Overall, estrogen receptor-positive (ER+) BC was the most representative type in 172 patients (78.2%). However, this was 83.9% in the high-dose cases group. The most used drug was denosumab. Twenty-five patients (26.9%) switched their medication from ZOL to denosumab during their oncological treatment. Patients with ER+ breast cancer were reported in 88 patients (87.8%) in the adjuvant group that was treated with ZOL. Conclusions: MRONJ was diagnosed only in the high-dose AR group. Dental assessment and care of patients in the adjuvant group should be considered, with a recommendation to potentially prolong ZOL treatment from 3 to 5 years, with concomitant use of hormonal therapy in patients diagnosed with ER+ breast cancer to prevent bone loss induced by oncological treatment. A new referral for dental assessment is very important in the case of bone metastases when treatment with high dose AR will be required since it is associated with a higher risk of MRONJ.

Keywords: antiresorptive therapy, breast cancer, dental care, MRONJ

Procedia PDF Downloads 51
72 Gait Analysis in Total Knee Arthroplasty

Authors: Neeraj Vij, Christian Leber, Kenneth Schmidt

Abstract:

Introduction: Total knee arthroplasty is a common procedure. It is well known that the biomechanics of the knee do not fully return to their normal state. Motion analysis has been used to study the biomechanics of the knee after total knee arthroplasty. The purpose of this scoping review is to summarize the current use of gait analysis in total knee arthroplasty and to identify the preoperative motion analysis parameters for which a systematic review aimed at determining the reliability and validity may be warranted. Materials and Methods: This IRB-exempt scoping review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses extension for Scoping Reviews (PRISMA-ScR) checklist strictly. Five search engines were searched for a total of 279 articles. Articles underwent a title and abstract screening process followed by full-text screening. Included articles were placed in the following sections: the role of gait analysis as a research tool for operative decisions, other research applications for motion analysis in total knee arthroplasty, gait analysis as a tool in predicting radiologic outcomes, gait analysis as a tool in predicting clinical outcomes. Results: Eleven articles studied gait analysis as a research tool in studying operative decisions. Motion analysis is currently used to study surgical approaches, surgical techniques, and implant choice. Five articles studied other research applications for motion analysis in total knee arthroplasty. Other research applications for motion analysis currently include studying the role of the unicompartmental knee arthroplasty and novel physical therapy protocols aimed at optimizing post-operative care. Two articles studied motion analysis as a tool for predicting radiographic outcomes. Preoperative gait analysis has identified parameters than can predict postoperative tibial component migration. 15 articles studied motion analysis in conjunction with clinical scores. Conclusions: There is a broad range of applications within the research domain of total knee arthroplasty. The potential application is likely larger. However, the current literature is limited by vague definitions of ‘gait analysis’ or ‘motion analysis’ and a limited number of articles with preoperative and postoperative functional and clinical measures. Knee adduction moment, knee adduction impulse, total knee range of motion, varus angle, cadence, stride length, and velocity have the potential for integration into composite clinical scores. A systematic review aimed at determining the validity, reliability, sensitivities, and specificities of these variables is warranted.

Keywords: motion analysis, joint replacement, patient-reported outcomes, knee surgery

Procedia PDF Downloads 66
71 An Inherent Risk to Damage the Popliteus Tendon by Some Femoral Component Designs: A Pilot Study in Indian Knees

Authors: Rajendra Kanojia

Abstract:

Femoral components with inbuilt rotation require thicker flexion resection of the lateral femoral condyle and could potential risk to damage the popliteus tendon especially in the smaller Asian knees. We prospectively evaluated 10 patients with bilateral varus osteoarthritis knee to size the cuts and their location in relation to the popliteus tendon. Two different types of implant were used on either side, one side requires resection in 3° external rotation (group A) and other side femoral component with inbuilt external roation (group B). We had popliteus tendon injury in 3 knees all from group B. Risk of damaging the popliteus tendon was found higher in group B.

Keywords: popliteaus tendon injury, TKA, orthopaedic surgery, biomechanics and clinical applications

Procedia PDF Downloads 305
70 An Ergonomic Handle Design for Instruments in Laparoscopic Surgery

Authors: Ramon Sancibrian, Carlos Redondo-Figuero, Maria C. Gutierrez-Diez, Esther G. Sarabia, Maria A. Benito-Gonzalez, Jose C. Manuel-Palazuelos

Abstract:

In this paper, the design and evaluation of a handle for laparoscopic surgery is presented. The design of the handle is based on ergonomic principles and tries to avoid awkward postures for surgeons. The handle combines the so-called power-grip and accurate-grip in order to provide strength and accuracy in the performance of surgery. The handle is tested using both objective and subjective approaches. The objective approach uses motion capture techniques to obtain the angles of forearm, arm, wrist and hand. The muscular effort is obtained with electromyography electrodes. On the other hand, a subjective survey has been carried out using questionnaires. Results confirm that the handle is preferred by the majority of the surgeons.

Keywords: laparoscopic surgery, ergonomics, mechanical design, biomechanics

Procedia PDF Downloads 471
69 The Effectiveness of Exercise Therapy on Decreasing Pain in Women with Temporomandibular Disorders and How Their Brains Respond: A Pilot Randomized Controlled Trial

Authors: Zenah Gheblawi, Susan Armijo-Olivo, Elisa B. Pelai, Vaishali Sharma, Musa Tashfeen, Angela Fung, Francisca Claveria

Abstract:

Due to physiological differences between men and women, pain is experienced differently between the two sexes. Chronic pain disorders, notably temporomandibular disorders (TMDs), disproportionately affect women in diagnosis, and pain severity in opposition of their male counterparts. TMDs are a type of musculoskeletal disorder that target the masticatory muscles, temporalis muscle, and temporomandibular joints, causing considerable orofacial pain which can usually be referred to the neck and back. Therapeutic methods are scarce, and are not TMD-centered, with the latest research suggesting that subjects with chronic musculoskeletal pain disorders have abnormal alterations in the grey matter of their brains which can be remedied with exercise, and thus, decreasing the pain experienced. The aim of the study is to investigate the effects of exercise therapy in TMD female patients experiencing chronic jaw pain and to assess the consequential effects on brain activity. In a randomized controlled trial, the effectiveness of an exercise program to improve brain alterations and clinical outcomes in women with TMD pain will be tested. Women with chronic TMD pain will be randomized to either an intervention arm or a placebo control group. Women in the intervention arm will receive 8 weeks of progressive exercise of motor control training using visual feedback (MCTF) of the cervical muscles, twice per week. Women in the placebo arm will receive innocuous transcutaneous electrical nerve stimulation during 8 weeks as well. The primary outcomes will be changes in 1) pain, measured with the Visual Analogue Scale, 2) brain structure and networks, measured by fractional anisotropy (brain structure) and the blood-oxygen level dependent signal (brain networks). Outcomes will be measured at baseline, after 8 weeks of treatment, and 4 months after treatment ends and will determine effectiveness of MCTF in managing TMD, through improved clinical outcomes. Results will directly inform and guide clinicians in prescribing more effective interventions for women with TMD. This study is underway, and no results are available at this point. The results of this study will have substantial implications on the advancement in understanding the scope of plasticity the brain has in regards with pain, and how it can be used to improve the treatment and pain of women with TMD, and more generally, other musculoskeletal disorders.

Keywords: exercise therapy, musculoskeletal disorders, physical therapy, rehabilitation, tempomandibular disorders

Procedia PDF Downloads 262
68 Realistic Study Discover Some Posture Deformities According to Some Biomechanical Variables for Schoolchildren

Authors: Basman Abdul Jabbar

Abstract:

The researchers aimed to improve the importance of the good posture without any divisions & deformities. The importance of research lied in the discovery posture deformities early so easily treated before its transformation into advanced abnormalities difficult to treat and may need surgical intervention. Research problem was noting that some previous studies were based on the discovery of posture deformities, which was dependent on the (self-evaluation) which this type did not have accuracy to discover deformities. The Samples were (500) schoolchildren aged (9-11 years, males) at Baghdad al Karak. They were students at primary schools. The measure included all posture deformities. The researcher used video camera to analyze the posture deformities according to biomechanical variables by Kinovea software for motion analysis. The researcher recommended the need to use accurate scientific methods for early detection of posture deformities in children which contribute to the prevention and reduction of distortions.

Keywords: biomechanics, children, deformities, posture

Procedia PDF Downloads 256
67 A Biomimetic Uncemented Hip Resurfacing Versus Various Biomaterials Hip Resurfacing Implants

Authors: Karima Chergui, Hichem Amrani, Hammoudi Mazouz, Fatiha Mezaache

Abstract:

Cemented femoral resurfacings have experienced a revival for younger and more active patients. Future developments have shown that the uncemented version eliminates failures related to cementing implants. A three-dimensional finite element method (FEM) simulation was carried out in order to exploit a new resurfacing prothesis design named MARMEL, proposed by a recent study with Co–Cr–Mo material, for comparing a hip uncemented resurfacing with a novel carbon fiber/polyamide 12 (CF/PA12) composite to other hip resurfacing implants with various bio materials. From FE analysis, the von Mises stress range for the Composite hip resurfacing was much lower than that in the other hip resurfacing implants used in this comparison. These outcomes showed that the biomimetic hip resurfacing had the potential to reduce stress shielding and prevent from bone fracture compared to conventional hip resurfacing implants.

Keywords: biomechanics, carbon–fibre polyamide 12, finite element analysis, hip resurfacing

Procedia PDF Downloads 297
66 Cranioplasty With Custom Implant Realized Using 3D Printing Technology

Authors: R. Trad Khodja, A. Guessmi, R. Ghoul, A. Mahtout, S. A. Benbouali, M. A. Boulahlib

Abstract:

Cranioplasty is a surgical act that aims to restore cranial bone losses in order to protect the brain from external aggressions and to improve the patient's aesthetic appearance. This objective can be achieved by taking advantage of the current technological development in computer science and biomechanics. The objective of this paper is to present an approach for the realization of high-precision biocompatible cranial implants using new 3D printing technologies at the lowest cost. The proposed method is to reproduce the missing part of the skull by referring to its healthy contralateral part. Once the model is validated by the neurosurgeons, a mold is 3D printed for the production of a biocompatible implant in Poly-Methyl-Methacrylate (PMMA) acrylic cement. Using this procedure, ten patients underwent this procedure with excellent aesthetic results.

Keywords: cranioplasty, cranial defect, PMMA, 3d printing, custom made implants

Procedia PDF Downloads 15
65 Quantitative Analysis of Camera Setup for Optical Motion Capture Systems

Authors: J. T. Pitale, S. Ghassab, H. Ay, N. Berme

Abstract:

Biomechanics researchers commonly use marker-based optical motion capture (MoCap) systems to extract human body kinematic data. These systems use cameras to detect passive or active markers placed on the subject. The cameras use triangulation methods to form images of the markers, which typically require each marker to be visible by at least two cameras simultaneously. Cameras in a conventional optical MoCap system are mounted at a distance from the subject, typically on walls, ceiling as well as fixed or adjustable frame structures. To accommodate for space constraints and as portable force measurement systems are getting popular, there is a need for smaller and smaller capture volumes. When the efficacy of a MoCap system is investigated, it is important to consider the tradeoff amongst the camera distance from subject, pixel density, and the field of view (FOV). If cameras are mounted relatively close to a subject, the area corresponding to each pixel reduces, thus increasing the image resolution. However, the cross section of the capture volume also decreases, causing reduction of the visible area. Due to this reduction, additional cameras may be required in such applications. On the other hand, mounting cameras relatively far from the subject increases the visible area but reduces the image quality. The goal of this study was to develop a quantitative methodology to investigate marker occlusions and optimize camera placement for a given capture volume and subject postures using three-dimension computer-aided design (CAD) tools. We modeled a 4.9m x 3.7m x 2.4m (LxWxH) MoCap volume and designed a mounting structure for cameras using SOLIDWORKS (Dassault Systems, MA, USA). The FOV was used to generate the capture volume for each camera placed on the structure. A human body model with configurable posture was placed at the center of the capture volume on CAD environment. We studied three postures; initial contact, mid-stance, and early swing. The human body CAD model was adjusted for each posture based on the range of joint angles. Markers were attached to the model to enable a full body capture. The cameras were placed around the capture volume at a maximum distance of 2.7m from the subject. We used the Camera View feature in SOLIDWORKS to generate images of the subject as seen by each camera and the number of markers visible to each camera was tabulated. The approach presented in this study provides a quantitative method to investigate the efficacy and efficiency of a MoCap camera setup. This approach enables optimization of a camera setup through adjusting the position and orientation of cameras on the CAD environment and quantifying marker visibility. It is also possible to compare different camera setup options on the same quantitative basis. The flexibility of the CAD environment enables accurate representation of the capture volume, including any objects that may cause obstructions between the subject and the cameras. With this approach, it is possible to compare different camera placement options to each other, as well as optimize a given camera setup based on quantitative results.

Keywords: motion capture, cameras, biomechanics, gait analysis

Procedia PDF Downloads 290
64 Design and Biomechanical Analysis of a Transtibial Prosthesis for Cyclists of the Colombian Team Paralympic

Authors: Jhonnatan Eduardo Zamudio Palacios, Oscar Leonardo Mosquera Dussan, Daniel Guzman Perez, Daniel Alfonso Botero Rosas, Oscar Fabian Rubiano Espinosa, Jose Antonio Garcia Torres, Ivan Dario Chavarro, Ivan Ramiro Rodriguez Camacho, Jaime Orlando Rodriguez

Abstract:

The training of cilsitas with some type of disability finds in the technological development an indispensable ally, generating every day advances to contribute to the quality of life allowing to maximize the capacities of the athletes. The performance of a cyclist depends on physiological and biomechanical factors, such as aerodynamic profile, bicycle measurements, connecting rod length, pedaling systems, type of competition, among others. This study particularly focuses on the description of the dynamic model of a transtibial prosthesis for Paralympic cyclists. To make the model, two points are chosen: in the radius centers of rotation of the plate and pinion of the track bicycle. The parametric scheme of the track bike represents a model of 6 degrees of freedom due to the displacement in X - Y of each of the reference points of the angles of the curve profile β, cant of the velodrome α and the angle of rotation of the connecting rod φ. The force exerted on the crank of the bicycle varies according to the angles of the curve profile β, the velodrome cant of α and the angle of rotation of the crank φ. The behavior is analyzed through the Matlab R2015a software. The average strength that a cyclist exerts on the cranks of a bicycle is 1,607.1 N, the Paralympic cyclist must perform a force on each crank about 803.6 N. Once the maximum force associated with the movement has been determined, it is continued to the dynamic modeling of the transtibial prosthesis that represents a model of 6 degrees of freedom with displacement in X - Y in relation to the angles of rotation of the hip π, knee γ and ankle λ. Subsequently, an analysis of the kinematic behavior of the prosthesis was carried out by means of SolidWorks 2017 and Matlab R2015a, which was used to model and analyze the variation of the hip angles π, knee γ and ankle of the λ prosthesis. The reaction forces generated in the prosthesis were performed on the ankle of the prosthesis, performing the summation of forces on the X and Y axes. The same analysis was then applied to the tibia of the prosthesis and the socket. The reaction force of the parts of the prosthesis varies according to the hip angles π, knee γ and ankle of the prosthesis λ. Therefore, it can be deduced that the maximum forces experienced by the ankle of the prosthesis is 933.6 N on the X axis and 2.160.5 N on the Y axis. Finally, it is calculated that the maximum forces experienced by the tibia and the socket of the transtibial prosthesis in high performance competitions is 3.266 N on the X axis and 1.357 N on the Y axis. In conclusion, it can be said that the performance of the cyclist depends on several physiological factors, linked to biomechanics of training. The influence of biomechanical factors such as aerodynamics, bicycle measurements, connecting rod length, or non-circular pedaling systems on the cyclist performance.

Keywords: biomechanics, dynamic model, paralympic cyclist, transtibial prosthesis

Procedia PDF Downloads 302
63 A Non-linear Damage Model For The Annulus Of the Intervertebral Disc Under Cyclic Loading, Including Recovery

Authors: Shruti Motiwale, Xianlin Zhou, Reuben H. Kraft

Abstract:

Military and sports personnel are often required to wear heavy helmets for extended periods of time. This leads to excessive cyclic loads on the neck and an increased chance of injury. Computational models offer one approach to understand and predict the time progression of disc degeneration under severe cyclic loading. In this paper, we have applied an analytic non-linear damage evolution model to estimate damage evolution in an intervertebral disc due to cyclic loads over decade-long time periods. We have also proposed a novel strategy for inclusion of recovery in the damage model. Our results show that damage only grows 20% in the initial 75% of the life, growing exponentially in the remaining 25% life. The analysis also shows that it is crucial to include recovery in a damage model.

Keywords: cervical spine, computational biomechanics, damage evolution, intervertebral disc, continuum damage mechanics

Procedia PDF Downloads 536
62 A Remedy for the Confusing Occlusal Principles - An Approach to a Passionate, In-Depth Understanding of Tooth Surfaces Dynamics

Authors: Kariem Elhelow

Abstract:

The task of optimizing teeth surface relations remains perplexing for many dental practitioners. The well-being of teeth, periodontium, and the musculoskeletal system is closely associated with occlusal stability. Dental occlusion is rather far beyond the simple contact of the occlusal surfaces of the opposite jaws, a fact that turned the word “Occlusion” into one of the most complicated puzzles in dentistry. The literature describing the pathological approaches made the practice of occlusion even more intimidating. Understanding the biomechanics of teeth and jaw movements makes the goals of occlusal rehabilitation very lively and simple to practice. The purpose of this article is to establish a path for understanding and practicing the fundamental occlusal principles in a simple yet in depth way. Relying of the evidence based core would deliver a context for showing that occlusion is not as complicated as literatures might reflect. Conclusion: Maintaining a well-defined picture of what a healthy occlusion should be like is very gratifying to both the operator and the patient, with added worth of predictability, esthetics, and function to the whole treatment.

Keywords: occlusal, temporomandibular joint, prosthetic, dentition

Procedia PDF Downloads 99
61 The Optimization Process of Aortic Heart Valve Stent Geometry

Authors: Arkadiusz Mezyk, Wojciech Klein, Mariusz Pawlak, Jacek Gnilka

Abstract:

The aortic heart valve stents should fulfill many criterions. These criteria have a strong impact on the geometrical shape of the stent. Usually, the final construction of stent is a result of many year experience and knowledge. Depending on patents claims, different stent shapes are produced by different companies. This causes difficulties for biomechanics engineers narrowing the domain of feasible solutions. The paper present optimization method for stent geometry defining by a specific analytical equation based on various mathematical functions. This formula was implemented as APDL script language in ANSYS finite element environment. For the purpose of simulation tests, a few parameters were separated from developed equation. The application of the genetic algorithms allows finding the best solution due to selected objective function. Obtained solution takes into account parameters such as radial force, compression ratio and coefficient of expansion on the transverse axial.

Keywords: aortic stent, optimization process, geometry, finite element method

Procedia PDF Downloads 256
60 A Review on Enhancing Heat Transfer Processes by Open-Cell Metal Foams and Industrial Applications

Authors: S. Cheragh Dar, M. Saljooghi, A. Babrgir

Abstract:

In the last couple of decades researchers' attitudes were focused on developing and enhancing heat transfer processes by using new components or cellular solids that divide into stochastic structures and periodic structures. Open-cell metal foams are part of stochastic structures families that they can be considered as an avant-garde technology and they have unique properties, this porous media can have tremendous achievements in thermal processes. This paper argues and surveys postulating possible in industrial thermal issues which include: compact electronic cooling, heat exchanger, aerospace, fines, turbo machinery, automobiles, crygen tanks, biomechanics, high temperature filters and etc. Recently, by surveying exponential rate of publications in thermal open-cell metal foams, all can be demonstrated in a holistic view which can lead researchers to a new level of understanding in different industrial thermal sections.

Keywords: heat transfer, industrial thermal, cellular solids, open cell metal foam

Procedia PDF Downloads 272
59 Cranioplasty with Custom Implant Realized Using 3D Printing Technology

Authors: Trad Khodja Rafik, Mahtout Amine, Ghoul Rachid, Benbouali Amine, Boulahlib Amine, Hariza Abdelmalik

Abstract:

Cranioplasty with custom implant realized using 3D printing technology. Cranioplasty is a surgical act that aims restoring cranial bone losses in order to protect the brain from external aggressions and to improve the patient aesthetic appearance. This objective can be achieved with taking advantage of the current technological development in computer science and biomechanics. The objective of this paper it to present an approach for the realization of high precision biocompatible cranial implants using new 3D printing technologies at the lowest cost. The proposed method is to reproduce the missing part of the skull by referring to its healthy contralateral part. Once the model is validated by the neurosurgeons, a mold is 3D printed for the production of a biocompatible implant in Poly-Methyl-Methacrylate (PMMA) acrylic cement. Using this procedure four patients underwent this procedure with excellent aesthetic results.

Keywords: cranioplasty, cranial bone loss, 3D printing technology, custom-made implants, PMMA

Procedia PDF Downloads 80
58 Human Facial Emotion: A Comparative and Evolutionary Perspective Using a Canine Model

Authors: Catia Correia Caeiro, Kun Guo, Daniel Mills

Abstract:

Despite its growing interest, emotions are still an understudied cognitive process and their origins are currently the focus of much debate among the scientific community. The use of facial expressions as traditional hallmarks of discrete and holistic emotions created a circular reasoning due to a priori assumptions of meaning and its associated appearance-biases. Ekman and colleagues solved this problem and laid the foundations for the quantitative and systematic study of facial expressions in humans by developing an anatomically-based system (independent from meaning) to measure facial behaviour, the Facial Action Coding System (FACS). One way of investigating emotion cognition processes is by applying comparative psychology methodologies and looking at either closely-related species (e.g. chimpanzees) or phylogenetically distant species sharing similar present adaptation problems (analogy). In this study, the domestic dog was used as a comparative animal model to look at facial expressions in social interactions in parallel with human facial expressions. The orofacial musculature seems to be relatively well conserved across mammal species and the same holds true for the domestic dog. Furthermore, the dog is unique in having shared the same social environment as humans for more than 10,000 years, facing similar challenges and acquiring a unique set of socio-cognitive skills in the process. In this study, the spontaneous facial movements of humans and dogs were compared when interacting with hetero- and conspecifics as well as in solitary contexts. In total, 200 participants were examined with FACS and DogFACS (The Dog Facial Action Coding System): coding tools across four different emotionally-driven contexts: a) Happiness (play and reunion), b) anticipation (of positive reward), c) fear (object or situation triggered), and d) frustration (negation of a resource). A neutral control was added for both species. All four contexts are commonly encountered by humans and dogs, are comparable between species and seem to give rise to emotions from homologous brain systems. The videos used in the study were extracted from public databases (e.g. Youtube) or published scientific databases (e.g. AM-FED). The results obtained allowed us to delineate clear similarities and differences on the flexibility of the facial musculature in the two species. More importantly, they shed light on what common facial movements are a product of the emotion linked contexts (the ones appearing in both species) and which are characteristic of the species, revealing an important clue for the debate on the origin of emotions. Additionally, we were able to examine movements that might have emerged for interspecific communication. Finally, our results are discussed from an evolutionary perspective adding to the recent line of work that supports an ancient shared origin of emotions in a mammal ancestor and defining emotions as mechanisms with a clear adaptive purpose essential on numerous situations, ranging from maintenance of social bonds to fitness and survival modulators.

Keywords: comparative and evolutionary psychology, emotion, facial expressions, FACS

Procedia PDF Downloads 406
57 The Effects of Seat Heights and Obesity on Lower-Limb Joint Kinematics during Sit-To-Stand Movement

Authors: Seungwon Baek, Haeseok Jeong, Haehyun Lee, Woojin Park

Abstract:

The main purpose of this study was to compare obese people to the non-obese in terms of joint kinematics in lower-limb body. The height of chairs was also considered as a design factor. Obese people had a difficulty in sit-to-stand (STS) tasks compared to the non-obese people. High chair heights can make STS task easy and it helps the obese to be more comfortable with STS task in particular. Subjects were instructed to wear inertial measurement unit (IMU) sensors. They perform STS task using chairs of different heights. Joint kinematics and subjective ratings of discomfort were measured. Knee angles of the obese group were greater than that of the non-obese group in normal type. No significant difference in joint kinematics was found in high chair. Interaction effect was found between obesity and height of chair. The results verified the previous research that had suggested a biomechanical model of STS movement. The results can be applied to occupational design for the obese.

Keywords: biomechanics, electromyography, joint kinematics, obesity, sitting, sit-to-stand

Procedia PDF Downloads 277
56 Analysis of the Evolution of Techniques and Review in Cleft Surgery

Authors: Tomaz Oliveira, Rui Medeiros, André Lacerda

Abstract:

Introduction: Cleft lip and/or palate are the most frequent forms of congenital craniofacial anomalies, affecting mainly the middle third of the face and manifesting by functional and aesthetic changes. Bilateral cleft lip represents a reconstructive surgical challenge, not only for the labial component but also for the associated nasal deformation. Recently, the paradigm of the approach to this pathology has changed, placing the focus on muscle reconstruction and anatomical repositioning of the nasal cartilages in order to obtain the best aesthetic and functional results. The aim of this study is to carry out a systematic review of the surgical approach to bilateral cleft lip, retrospectively analyzing the case series of Plastic Surgery Service at Hospital Santa Maria (Lisbon, Portugal) regarding this pathology, the global assessment of the characteristics of the operated patients and the study of the different surgical approaches and their complications in the last 20 years. Methods: The present work demonstrates a retrospective and descriptive study of patients who underwent at least one reconstructive surgery for cleft lip and/or palate, in the CPRE service of the HSM, in the period between January 1 of 1997 and December 31 of 2017, in which the data relating to 361 individuals were analyzed who, after applying the exclusion criteria, constituted a sample of 212 participants. The variables analyzed were the year of the first surgery, gender, age, type of orofacial cleft, surgical approach, and its complications. Results: There was a higher overall prevalence in males, with cleft lip and cleft palate occurring in greater proportion in males, with the cleft palate being more common in females. The most frequently recorded malformation was cleft lip and palate, which is complete in most cases. Regarding laterality, alterations with a unilateral labial component were the most commonly observed, with the left lip being described as the most affected. It was found that the vast majority of patients underwent primary intervention up to 12 months of age. The surgical techniques used in the approach to this pathology showed an important chronological variation over the years. Discussion: Cleft lip and/or palate is a medical condition associated with high aesthetic and functional morbidity, which requires early treatment in order to optimize the long-term outcome. The existence of a nasolabial component and its respective surgical correction plays a central role in the treatment of this pathology. The high rates of post-surgical complications and unconvincing aesthetic results have motivated an evolution of the surgical technique, increasingly evident in recent years, allowing today to achieve satisfactory aesthetic results, even in bilateral cleft lip with high deformation complexity. The introduction of techniques that favor nasolabial reconstruction based on anatomical principles has been producing increasingly convincing results. The analyzed sample shows that most of the results obtained in this study are, in general, compatible with the results published in the literature. Conclusion: This work showed that the existence of small variations in the surgical technique can bring significant improvements in the functional and aesthetic results in the treatment of bilateral cleft lip.

Keywords: cleft lip, palate lip, congenital abnormalities, cranofacial malformations

Procedia PDF Downloads 82
55 Advances in Axonal Biomechanics and Mechanobiology: A Nanotechnology-Based Approach to the Study of Mechanotransduction of Axonal Growth

Authors: Alessandro Falconieri, Sara De Vincentiis, Vittoria Raffa

Abstract:

Mechanical force regulates axonal growth, elongation and maturation processes. This force is opening new frontiers in the field, contributing to a general understanding of the mechanisms of axon growth that, in the past, was thought to be governed exclusively by the growth cone and its ability to influence axonal growth in response to chemical signals. A method recently developed in our laboratory allows, through the labeling of neurons with magnetic nanoparticles (MNPs) and the use of permanent magnets, to apply extremely low mechanical forces, similar to those generated endogenously by the growth cone or by the increase of body mass during the organism growth. We found that these extremely low forces strongly enhance the spontaneous axonal elongation rate as well as neuronal sprouting. Data obtained don’t exclude that local phenomena, such as local transport and local translation, may be involved. These new advances could shed new light on what happens when the cell is subjected to external mechanical forces, opening new interesting scenarios in the field of mechanobiology.

Keywords: axon, external mechanical forces, magnetic nanoparticles, mechanotransduction

Procedia PDF Downloads 99
54 Comparison of the Effects of Rod Types of Rigid Fixation Devices on the Loads in the Lumbar Spine: A Finite Element Analysis

Authors: Bokku Kang, Changsoo Chon, Han Sung Kim

Abstract:

We developed new design of rod of pedicle screw system that is beneficial in maintaining the spacing between the vertebrae and assessed the performance of the posterior fixation screw systems by numerical analysis according to the range of motion (flexion, extension, lateral bending, and axial rotation) of the vertebral column after inserting the pedicle screws. The simulation results showed that the conventional rod was the most low equivalent stress value among implant units in the case of flexion, extension and lateral bending of the vertebrae. In all cases except the torsional rotation, the results showed that the stress level of the single and double rounded rod exceeded about 30% to 70% compare to the conventional rod. Therefore, this product is not suitable for actual application in the field yet and it seems that product design optimization is necessary. Acknowledgement: This research was supported by the Ministry of Trade, Industry & Energy (MOTIE), Korea Institute for Advancement of Technology (KIAT) through the Encouragement Program for The Industries of Economic Cooperation Region.

Keywords: lumber spine, internal fixation device, finite element method, biomechanics

Procedia PDF Downloads 355
53 The Actuation of Semicrystalline Poly(Vinylidene Fluoride) Tie Molecules: A Computational and Experimental Study

Authors: Abas Mohsenzadeh, Tariq Bashir, Waseen Tahir, Ulf Stigh, Mikael Skrifvars, Kim Bolton

Abstract:

The area of artificial muscles has received significant attention from many research domains including soft robotics, biomechanics and smart textiles in recent years. Poly(vinylidene fluoride) (PVDF) has been used to form artificial muscles since it contracts upon heating when under load. In this study, PVDF fibers were produced by melt spinning technique at different solid state draw ratios and then actuation mechanism for PVDF tie molecules within the semicrystalline region of PVDF polymer has been investigated using molecular dynamics simulations. Tie molecules are polymer chains that link two (or more) crystalline regions in semicrystalline polymers. The changes in fiber length upon heating have been investigated using a novel simulation technique. The results show that conformational changes of the tie molecules from the longer all-trans conformation at low temperature (β structure) to the shorter conformation (α structure) at higher temperature accrue by increasing the temperature. These results may be applied to understand the actuation observed for PVDF upon heating.

Keywords: poly(vinylidene fluoride), molecular dynamics, simulation, actuators, tie molecules, semicrystalline

Procedia PDF Downloads 278
52 Morphology of the Acetabular Cartilage Surface in Elderly Cadavers Analyzing the Contact between the Acetabulum and Femoral Head

Authors: Keisuke Akiyama, Takashi Sakai, Junichiro Koyanagi, Hideki Yoshikawa, Kazuomi Sugamoto

Abstract:

The geometry of acetabular cartilage surface plays an important role in hip joint biomechanics. The aim of this study was to analyze the morphology of acetabular articular cartilage surface in elderly subjects using a 3D-digitizer. Twenty hemipelves from 12 subjects (mean ages 85 years) were scanned with 3D-digitizer. Each acetabular surface model was divided into four regions: anterosuperior (AS), anteroinferior (AI), posterosuperior (PS), and posteroinferior (PI). In the global acetabulum and each region, the acetabular sphere radius and the standard deviation (SD) of the distance from the acetabular sphere center to the acetabular cartilage surface were calculated. In the global acetabulum, the distance between the acetabular surface model and the maximum sphere which did not penetrate over the acetabular surface model was calculated as the inferred femoral head, and then the distribution was mapped at intervals of 0.5 mm. The SD in AS was significantly larger than that in AI (p = 0.006) and PI (p = 0.001). The SD in PS was significantly larger than that in PI (p = 0.005). The closest region (0-0.5 mm) tended to be distributed at anterior or posterosuperior acetabular edge. The contact between the femoral head and acetabulum might start at the periphery of the lunate surface, especially in the anterior or posterosuperior region. From viewpoint of acetabular morphology, the acetabular articular cartilage in the anterior or posterosuperior edge could be more vulnerable due to direct contact mechanism.

Keywords: acetabulum, cartilage, morphology, 3D-digitizer

Procedia PDF Downloads 320
51 Immediate Effect of Augmented Feedback on Jumping Performance of the Athletes with Dynamic Knee Valgus

Authors: Mohamadreza Hatefi, Malihe Hadadnezhad

Abstract:

It is well established that jump-landing-related biomechanical deficiencies, such as dynamic knee valgus (DKV), can be improved by using various forms of feedback; However, the effectiveness of these interventions synchronously on athletes' jumping performance remains unknown. Twenty-one recreational athletes with DKV performed countermovement jump (CMJ) and drop vertical jump (DVJ) tasks before and after feedback intervention while the kinematic, force plate and electromyography data of the lower extremity were synchronously captured. The athletes’ jumping performance was calculated by using the reactive strength index-modified (RSIₘₒ𝒹). The athletes at the post-intervention exhibited significantly less hip adduction and more tibial internal rotation during both CMJ and DVJ tasks and maximum knee flexion just during DVJ task. Moreover, athletes exhibited increased time to take-off and consequently decreased RSIₘₒ𝒹 during DVJ task, but no difference was observed in CMJ task. Feedback immediately improved DKV without disturbing the athletes’ jumping height during both tasks, But athletes exhibited increased time to take-off and consequently decreased RSIₘₒ𝒹 only during DVJ task, which suggests that the results may differ according to the nature of jumping task. Nevertheless, the effectiveness of landing-related biomechanical deficiencies improvement on athletes' jumping performance must be investigated in the long-term as a new movement pattern.

Keywords: reactive strength index, feedback, biomechanics, dynamic knee valgus

Procedia PDF Downloads 76
50 Dietary Index Associated With Plantar Pressure in Older Women

Authors: Lovro Štefan

Abstract:

The main purpose of the study was to explore if a higher level of Elderly Dietary index score was correlated with lower peak plantar pressures. One-hundred and twenty older adults aged ≥60 years participated in this cross-sectional study. To assess the level of adherence to nutritional recommendations for older adults, we used Elderly Dietary Index score. Plantar pressures beneath the forefoot, midfootandhindfootregions of the foot were determined by pressure platform. Pearson’s coefficient of correlations and partial correlations were used to calculate the relationships. In the unadjusted model, higher Elderly Dietary Index was significantly correlated with lower peak plantar pressure beneath the forefoot (r = -0.45, p<0.001) and hindfoot (r = -0.37, p<0.001) the region, while no significant correlation with peak plantar pressure beneath the (r = -0.15, p=0.113) was observed. When we adjusted for age, body-mass index and gait velocity, higher Elderly Dietary Index remained significantly correlated with lower peak plantar pressure beneath the forefoot (r = -0.41, p<0.001) and hintfoot (r = -0.32, p<0.001) region. This study shows that higher adherence to nutritional recommendations is significantly correlated with lower forefoot and hindfoot peak plantar pressures in older women.

Keywords: elderly, biomechanics, nutrition, associations, force

Procedia PDF Downloads 60
49 Measuring the Biomechanical Effects of Worker Skill Level and Joystick Crane Speed on Forestry Harvesting Performance Using a Simulator

Authors: Victoria L. Chester, Usha Kuruganti

Abstract:

The forest industry is a major economic sector of Canada and also one of the most dangerous industries for workers. The use of mechanized mobile forestry harvesting machines has successfully reduced the incidence of injuries in forest workers related to manual labor. However, these machines have also created additional concerns, including a high machine operation learning curve, increased the length of the workday, repetitive strain injury, cognitive load, physical and mental fatigue, and increased postural loads due to sitting in a confined space. It is critical to obtain objective performance data for employers to develop appropriate work practices for this industry, however ergonomic field studies of this industry are lacking mainly due to the difficulties in obtaining comprehensive data while operators are cutting trees in the woods. The purpose of this study was to establish a measurement and experimental protocol to examine the effects of worker skill level and movement training speed (joystick crane speed) on harvesting performance using a forestry simulator. A custom wrist angle measurement device was developed as part of the study to monitor Euler angles during operation of the simulator. The device of the system consisted of two accelerometers, a Bluetooth module, three 3V coin cells, a microcontroller, a voltage regulator and an application software. Harvesting performance and crane data was provided by the simulator software and included tree to frame collisions, crane to tree collisions, boom tip distance, number of trees cut, etc. A pilot study of 3 operators with various skill levels was tested to identify factors that distinguish highly skilled operators from novice or intermediate operators. Dependent variables such as reaction time, math skill, past work experience, training movement speed (e.g. joystick control speeds), harvesting experience level, muscle activity, and wrist biomechanics were measured and analyzed. A 10-channel wireless surface EMG system was used to monitor the amplitude and mean frequency of 10 upper extremity muscles during pre and postperformance on the forestry harvest stimulator. The results of the pilot study showed inconsistent changes in median frequency pre-and postoperation, but there was the increase in the activity of the flexor carpi radialis, anterior deltoid and upper trapezius of both arms. The wrist sensor results indicated that wrist supination and pronation occurred more than flexion and extension with radial-ulnar rotation demonstrating the least movement. Overall, wrist angular motion increased as the crane speed increased from slow to fast. Further data collection is needed and will help industry partners determine those factors that separate skill levels of operators, identify optimal training speeds, and determine the length of training required to bring new operators to an efficient skill level effectively. In addition to effective and employment training programs, results of this work will be used for selective employee recruitment strategies to improve employee retention after training. Further, improved training procedures and knowledge of the physical and mental demands on workers will lead to highly trained and efficient personnel, reduced risk of injury, and optimal work protocols.

Keywords: EMG, forestry, human factors, wrist biomechanics

Procedia PDF Downloads 115
48 Virtual Test Model for Qualification of Knee Prosthesis

Authors: K. Zehouani, I. Oldal

Abstract:

Purpose: In the human knee joint, degenerative joint disease may happen with time. The standard treatment of this disease is the total knee replacement through prosthesis implanting. The reason lies in the fact that this phenomenon causes different material abrasion as compare to pure sliding or rolling alone. This study focuses on developing a knee prosthesis geometry, which fulfills the mechanical and kinematical requirements. Method: The MSC ADAMS program is used to describe the rotation of the human knee joint as a function of flexion, and to investigate how the flexion and rotation movement changes between the condyles of a multi-body model of the knee prosthesis as a function of flexion angle (in the functional arc of the knee (20-120º)). Moreover, the multi-body model with identical boundary conditions is constituted, and the numerical simulations are carried out using the MSC ADAMS program system. Results: It is concluded that the use of the multi-body model reduces time and cost since it does not need to manufacture the tibia and the femur as it requires for the knee prosthesis of the test machine. Moreover, without measuring or by dispensing with a test machine for the knee prosthesis geometry, approximation of the results of our model to a human knee is carried out directly. Conclusion: The pattern obtained by the multi-body model provides an insight for future experimental tests related to the rotation and flexion of the knee joint concerning the actual average and friction load.

Keywords: biomechanics, knee joint, rotation, flexion, kinematics, MSC ADAMS

Procedia PDF Downloads 113
47 Fiber Braggs Grating Sensor Based Instrumentation to Evaluate Postural Balance and Stability on an Unstable Platform

Authors: K. Chethana, A. S. Guru Prasad, H. N. Vikranth, H. Varun, S. N. Omkar, S. Asokan

Abstract:

This paper describes a novel application of Fiber Braggs Grating (FBG) sensors on an unstable platform to assess human postural stability and balance. The FBG sensor based Stability Analyzing Device (FBGSAD) developed demonstrates the applicability of FBG sensors in the measurement of plantar strain to assess the postural stability of subjects on unstable platforms during different stances in eyes open and eyes closed conditions on a rocker board. Comparing the Centre of Gravity (CG) variations measured on the lumbar vertebra of subjects using a commercial accelerometer along with FBGSAD validates the study. The results obtained depict qualitative similarities between the data recorded by both FBGSAD and accelerometer, illustrating the reliability and consistency of FBG sensors in biomechanical applications for both young and geriatric population. The developed FBGSAD simultaneously measures plantar strain distribution and postural stability and can serve as a tool/yardstick to mitigate space motion sickness, identify individuals who are susceptible to falls and to qualify subjects for balance and stability, which are important factors in the selection of certain unique professionals such as aircraft pilots, astronauts, cosmonauts etc.

Keywords: biomechanics, fiber bragg gratings, plantar strain measurement, postural stability analysis

Procedia PDF Downloads 543
46 Biomechanical Evaluation of the Chronic Stroke with 3D-Printed Hand Device

Authors: Chen-Sheng Chen, Tsung-Yi Huang, Pi-Chang Sun

Abstract:

Chronic stroke patients often have complaints about hand dysfunction due to flexor hypertonia and extensor weakness, which makes it difficult to open their affected hand for functional grasp. Hand rehabilitation after stroke is essential for restoring functional independence. Constraint-induced movement therapy has shown to be a successful treatment for patients who have acquired certain level of wrist and finger extension. The goal of this study was to investigate the feasibility of task-oriented approach incorporating 3D-printed dynamic hand device by evaluating hand functional performance. This study manufactured a hand device using 3d printer for chronic stroke. The experimental group engaged task-oriented approach with dynamic hand device, but the control group only received task-oriented approach. Outcome measurements include palmar pinch force (PPF), lateral pinch force (LPF), grip force (GF), and Box and Blocks Test (BBT). The results of study revealed the improvement of PPF in experimental group but not in control group. Meanwhile, improvement in LPF, GF and BBT can be found in both groups. This study demonstrates that the 3D-printed dynamic hand device is an effective therapeutic assistive device to improve pinch force, grasp force, and dexterity and facilitate motivation during home program in individuals with chronic stroke.

Keywords: 3D printing, biomechanics, hand orthosis, stroke

Procedia PDF Downloads 235
45 Effect of Core Stability Exercises on Trunk Proprioception in Healthy Adult Individuals

Authors: Omaima E. S. Mohammed, Amira A. A. Abdallah, Amal A. M. El Borady

Abstract:

Background: Core stability training has recently attracted attention for improving muscle performance. Purpose: This study investigated the effect of beginners' core stability exercises on trunk active repositioning error at 30° and 60° trunk flexion. Methods: Forty healthy males participated in the study. They were divided into two equal groups; experimental “group I” and control “group II”. Their mean age, weight and height were 19.35±1.11 vs 20.45±1.64 years, 70.15±6.44 vs 72.45±6.91 kg and 174.7±7.02 vs 176.3±7.24 cm for group I vs group II. Data were collected using the Biodex Isokinetic system at an angular velocity of 60º/s. The participants were tested twice; before and after a 6-week period during which group I performed a core stability training program. Results: The Mixed 3-way ANOVA revealed significant increases (p<0.05) in the absolute error (AE) at 30˚ compared with 60˚ flexion in the pre-test condition of group I and II and the post-test condition of group II. Moreover, there were significant decreases (p<0.05) in the AE in the post-test condition compared with the pre-test in group I at both 30˚ and 60˚ flexion with no significant differences for group II. Finally, there were significant decreases (p<0.05) in the AE in group I compared with group II in the post-test condition at 30˚ and 60˚ flexion with no significant differences for the pre-test condition Interpretation/Conclusion: The improvement in trunk proprioception indicated by the decrease in the active repositioning error in the experimental group recommends including core stability training in the exercise programs that aim to improve trunk proprioception.

Keywords: core stability, isokinetic, trunk proprioception, biomechanics

Procedia PDF Downloads 446