Search results for: anterior gleno-humeral instability
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 833

Search results for: anterior gleno-humeral instability

803 Evaluation of the Golden Proportion and Golden Standard of Maxillary Anterior Teeth in Relation to Smile Attractiveness

Authors: Marwan Ahmed Swileh, Amal Hussein Abuaffan

Abstract:

Objective: This study aimed to explore the existence of golden proportion (GP) between the widths of maxillary anterior teeth and golden standard (GS) for width to height ratio of maxillary central incisor in individuals with attractive and non-attractive smiles. Materials and methods: A total of 82 females were recruited and divided into 2 groups: attractive smile (n= 41) and non-attractive smile (n= 41). Frontal photographs were taken, scanned, and saved on a personal computer. The apparent mesiodistal width of each anterior tooth was measured. The data were analyzed using the appropriate statistical tests at p-value < 0.05. Results: Frequency of GP was very low among the total sample, and most proportions were higher than GP. No significant differences were found between both groups in relation to central-to-lateral ratio while significant differences were found in relation to canine-to-lateral ratio. Similarly, most proportions of width to height ratio were higher than GS. Difference between groups was significant for left side and for both sides (p < 0.05) but was not for right side (p > 0.05). Conclusion: Frequency of golden proportion was very low among the study population. Smile attractiveness is not related that much to the proportions between the teeth.

Keywords: golden proportion, golden standard, attractive smile, esthetic, anterior teeth

Procedia PDF Downloads 115
802 The Richtmyer-Meshkov Instability Impacted by the Interface with Different Components Distribution

Authors: Sheng-Bo Zhang, Huan-Hao Zhang, Zhi-Hua Chen, Chun Zheng

Abstract:

In this paper, the Richtmyer-Meshkov instability has been studied numerically by using the high-resolution Roe scheme based on the two-dimensional unsteady Euler equation, which was caused by the interaction between shock wave and the helium circular light gas cylinder with different component distributions. The numerical results further discuss the deformation process of the gas cylinder, the wave structure of the flow field and quantitatively analyze the characteristic dimensions (length, height, and central axial width) of the gas cylinder, the volume compression ratio of the cylinder over time. In addition, the flow mechanism of shock-driven interface gas mixing is analyzed from multiple perspectives by combining it with the flow field pressure, velocity, circulation, and gas mixing rate. Then the effects of different initial component distribution conditions on interface instability are investigated. The results show when the diffusion interface transit to the sharp interface, the reflection coefficient gradually increases on both sides of the interface. When the incident shock wave interacts with the cylinder, the transmission of the shock wave will transit from conventional transmission to unconventional transmission. At the same time, the reflected shock wave is gradually strengthened, and the transmitted shock wave is gradually weakened, which leads to an increase in the Richtmyer-Meshkov instability. Moreover, the Atwood number on both sides of the interface also increases as the diffusion interface transit to the sharp interface, which leads to an increase in the Rayleigh-Taylor instability and the Kelvin-Helmholtz instability. Therefore, the increase in instability will lead to an increase the circulation, resulting in an increase in the growth rate of gas mixing rate.

Keywords: shock wave, He light cylinder, Richtmyer-Meshkov instability, Gaussian distribution

Procedia PDF Downloads 49
801 New Stress Instability Workability Criteria for Internal Ductile Failure in Steel Cold Heading

Authors: Amar Sabih, James Nemes

Abstract:

The occurrence of internal ductile failure within the Adiabatic Shear Band (ASB) in cold-headed products presents a significant barrier in the fast-expanding cold-heading (CH) industry. The presence of internal ductile failure in cold-headed products may lead to catastrophic fracture under tensile loads despite the ductile nature of the material causing expensive industrial recalls. Therefore, this paper presents a new workability criterion that uses stress instability as an indicator to accurately reveal the locus of initiation of internal ductile failures. The concept of the instability criterion is to use the stress ratio at failure as a weighting function to indicate the initiation of ductile failure inside the ASBs. This paper presents a comprehensive experimental, metallurgical, and finite element simulation study to calculate the material constants used in this criterion.

Keywords: adiabatic sher band, ductile failure, stress instability, workability criterion

Procedia PDF Downloads 56
800 Variation In Gastrocnemius and Hamstring Muscle Activity During Peak Knee Flexor Torque After Anterior Cruciate Ligament Reconstruction with Hamstring Graft

Authors: Luna Sequier, Florian Forelli, Maude Traulle, Amaury Vandebrouck, Pascal Duffiet, Louis Ratte, Jean Mazeas

Abstract:

The study's objective is to compare the muscular activity of the flexor knee muscle in patients who underwent an anterior cruciate ligament reconstruction with hamstring autograft and the individuals who have not undergone surgery. Methods: The participants were divided into two groups: a healthy group and an experimental group who had undergone an anterior cruciate ligament reconstruction with a hamstring graft. All participants had to perform a knee flexion strength test on an isokinetic dynamometer. The medial Gastrocnemius, lateral Gastrocnemius, Biceps femoris, and medial Hamstring muscle activity were measured during this test. Each group’s mean muscle activity was tested with statistical analysis, and a muscle activity ratio of gastrocnemius and hamstring muscles was calculated Results: The results showed a significant difference in activity of the medial gastrocnemius (p = 0,004901), the biceps femoris (p = 5,394.10-6), and the semitendinosus muscles (p = 1,822.10-6), with a higher Biceps femoris and Semitendinosus activity for the experimental group. It is however noticeable that inter-subject differences were important. Conclusion: This study has shown a difference in the gastrocnemius and hamstring muscle activity between patients who underwent an anterior cruciate ligament reconstruction surgery and healthy participants. With further results, this could show a modification of muscle activity patterns after surgery which could lead to compensatory behaviors at a return to sport and eventually explain a higher injury risk for our patients.

Keywords: anterior cruciate ligament, electromyography, muscle activity, physiotherapy

Procedia PDF Downloads 213
799 Experimental Investigations of a Modified Taylor-Couette Flow

Authors: Ahmed Esmael, Ali El Shrif

Abstract:

In this study the instability problem of a modified Taylor-Couette flow between two vertical coaxial cylinders of radius R1, R2 is considered. The modification is based on the wavy shape of the inner cylinder surface, where inner cylinders with different surface amplitude and wavelength are used. The study aims to discover the effect of the inner surface geometry on the instability phenomenon that undergoes Taylor-Couette flow. The study reveals that the transition processes depends strongly on the amplitude and wavelength of the inner cylinder surface and resulting in flow instabilities that are strongly different from that encountered in the case of the classical Taylor-Couette flow.

Keywords: hydrodynamic instability, Modified Taylor-Couette Flow, turbulence, Taylor vortices

Procedia PDF Downloads 409
798 A Novel Stress Instability Workability Criteria for Internal Ductile Failure in Steel Cold Heading Process

Authors: Amar Sabih, James Nemes

Abstract:

The occurrence of internal ductile failure within the Adiabatic Shear Band (ASB) in cold-headed products presents a significant barrier in the fast-expanding cold-heading (CH) industry. The presence of internal ductile failure in cold-headed products may lead to catastrophic fracture under tensile loads despite the ductile nature of the material causing expensive industrial recalls. Therefore, this paper presents a workability criterion that uses stress instability as an indicator to accurately reveal the locus of initiation of internal ductile failures. The concept of the instability criterion is to use the stress ratio at failure as a weighting function to indicate the initiation of ductile failure inside the ASBs. This paper presents a comprehensive experimental, metallurgical, and finite element simulation study to calculate the material constants used in this criterion.

Keywords: adiabatic shear band, workability criterion, ductile failure, stress instability

Procedia PDF Downloads 57
797 Anterior Chamber Depth Measured with Orbscan and Pentacam Compared with Smith Method in 102 Phakic Eyes

Authors: Mohammad Ghandehari Motlagh

Abstract:

Purpose: Comparing anterior chamber depth (ACD) measured with Orbscan II and Pentacam HR compared with the Smith method results. Methods: Smith method (1979) is a reliable method of measuring ACD only with help of slit lamp. In this study 102 phakic eyes as PRK candidates were imaged with both OrbScan and Pentacam and finally ACD was measured thru Smith method with slit lamp. ACD measured with Smith method was presumed as the gold standard and was compared with ACD of the 2 imaging devices. Contraindication cases for PRK and pseudophakic eyes have been excluded from the study. Results: Mean age of the patients was 35.2 ±14.8 yrs/old including 56 M(54.9%)and 46 F(45.09%).Acceptable correlation of ACD measured thru Smith method with Orbscan and Pentacam are R=0.958 and R=0.942 respectively and so Orbscan results can be used in procedures relying on ACD. Conclusion: ACDs measured with OrbScan is more precise than Pentacam and so can be more useful in some surgery procedures relying ACD results such as phakic IOLs and in cycloplegia contraindications.

Keywords: orbscan, pentacam, anterior chamber depth, slit lamp

Procedia PDF Downloads 344
796 Causes of Financial Instability and Banking Crises: A Comparative Study of Analytical Approaches

Authors: Laura Josabeth Oros-Avilés, Josefina León-León

Abstract:

In recent decades, the concern of the monetary authorities has increased because of the instability of the financial sector caused by the crash of speculative bubbles. In fact, the crash of "housing bubble" in U.S. (2007-2008) led the latest global crisis. The aim of paper is to analyze the features and causes of the financial and banking crisis from an historical view. In particular, in this research, a comparative study of some analytical approaches about economic and financial history is discussed. In addition, the role of monetary policy of central banks in managing financial crises, from its origins to today, is analyzed. According to the studied approaches, two types of factors that cause the financial instability were identified: subjective and objectives. In the research, these factors are deeply discussed, in order to noting the agreements and disagreement between the authors. Specially, it is worth noting that all of them recognized that the credit boom and the financial deregulation are the main causes of financial crises.

Keywords: asset prices, banking crises, financial bubble, financial instability, monetary policy

Procedia PDF Downloads 300
795 The Variation of the Inferior Gluteal Artery Origin

Authors: Waseem Al Talalwah, Shorok Al Dorazi, Roger Soames

Abstract:

The inferior gluteal artery is a prominent branch of the anterior trunk of internal iliac artery. It escapes from the pelvic cavity through the greater sciatic foramen below the lower edge of piriformis. In gluteal region, it provides several muscular branches to gluteal maximus and articular branch to hip joint. Further, it provides sciatic branch to sciatic nerve. Current study investigates the origin of the inferior gluteal artery of 41 cadavers in Centre for Anatomy and Human Identification, University of Dundee, UK. It arose from the anterior trunk in 37.5% independently and 45.7% dependently as with the internal pudendal artery. Therefore, it arose from the anterior trunk in 83.2%. However, it found to be as a branch of the posterior trunk of internal iliac artery in 7.7% which is either a direct branch in 6.2% as or indirect branch in 1.5%. Beside the inferior gluteal artery arose with internal pudendal artery as from GPT of anterior division in 45.7%, it arose from the GPT arising from the internal iliac artery bifurcation site in 1.5%. Further, the inferior gluteal artery arose from the trunk with internal pudendal and obturator arteries in 1.5% referred as obturatogluteopudendal trunk. Occasionally, it arose from the sciatic artery in 1.5%. In few cases, the inferior gluteal artery found to be congenital absence in 4.6% which is compensated by the persistent sciatic artery. Therefore, radiologists have to aware of the origin variability of the inferior gluteal artery to alert surgeons. Knowing the origin of the inferior gluteal artery may help the surgeons to avoid iatrogenic sciatic neuropathy in pelvic procedures such as removing prostate or of uterine fibroid. Further, it may also prevent avascular necrosis of femur neck as well as gluteal claudication.

Keywords: inferior gluteal artery, internal iliac artery, sciatic neuropathy, gluteal claudication

Procedia PDF Downloads 323
794 Bifid Ureters: Arising Directly from the Separate Calyces and Renal Pelvis of the Kidney: A Case Report

Authors: Yuri Seu, Hyun Jin Park, Jin Seo Park, Yong-Suk Moon, HongtaeKim, Mi-Sun Hur

Abstract:

The present case report describes bifid ureters arising directly from the separate calyces and renal pelvis of the kidney. It was a single common ureter leading away from the bladder, which was separated into incompletely duplicated ureters near the level of the anterior superior iliac supine. These two branches then entered the left kidney through their own courses. Each ureter traveled anterior and posterior to the renal vein, respectively. These two ureters formed a Y-shaped pattern. One ureter coursed anterior to the renal vein with shorter length, and it terminated at the renal pelvis that was divided into major calices in approximately lower two thirds of the kidney. The other ureter coursed posterior to the renal vein with longer length, terminating at approximately the upper third of the kidney. The renal calices in the upper third of the kidney were directly connected to the posterior ureter, whereas the other major calices in the lower two thirds of the kidney formed the renal pelvis connecting to the anterior ureter. Thus, convergence of the major calices was separated according to the terminations of two ureters. These anomalous ureters were traced to the calices of the kidney, thereby providing a reference of a rare variation of the ureter. The bifid ureters arising from the separate calyces and renal pelvis should be considered by radiologists when evaluating images and diagnosing possible complications of these anomalies.

Keywords: bifid ureters, kidney, major calices, renal pelvis

Procedia PDF Downloads 56
793 Morphometric Study of Human Anterior and Posterior Meniscofemoral Ligaments of the Knee Joint on Thiel Embalmed Cadavers

Authors: Mohammad Alobaidy, David Nicoll, Tracey Wilkinson

Abstract:

Background: Many patients suffer postoperative knee stability after total knee arthroplasty (joint replacement) involving posterior cruciate ligament (PCL) sacrificing or retaining, but is not clear whether the meniscofemoral ligaments (MFLs) are retained during these procedures; their function in terms of knee stability is not well established in the literature. Purpose: Macroscopic, detailed, morphometric investigation of the anterior and posterior MFLs of the knee joint was undertaken to assist understanding of knee stability after total knee arthroplasty and ligament reconstruction. Methods: Dissection of eighty Thiel embalmed knees from 19 male and 21 female cadavers was conducted, mean age 77 (range 47-99 years). The origin and insertion of the anterior and posterior MFLs were measured using high accuracy, calibrated, digital Vernier calipers at 0.01mm. Results: The means were: anterior meniscofemoral ligament (aMFL) length 28.4 ± 2.7mm; posterior meniscofemoral ligament (pMFL) length 29 ± 3.7mm; aMFL femoral width 6.4 ± 1.7mm, mid-distance ligament width 4 ± 1.1mm, meniscal ligament width 3.9 ± 1.2mm; pMFL femoral width 5.6 ± 1.5mm, mid-distance ligament width 4.1 ± 1.1mm, meniscal ligament width 4.1 ± 1.3mm. Some of the male measurements were larger than female, with significant differences in the length of the aMFL femoral length p<0.01 and pMFL femoral length p<0.007, and width of the pMFL mid-distance p<0.04. Conclusion: This study may help explore the role of the meniscofemoral ligaments in knee stability after total knee arthroplasty with a posterior cruciate ligament retaining prosthesis. Anatomical information for Thiel embalmed knees may aid orthopaedic surgeons in ligament reconstruction.

Keywords: anterior and posterior meniscofemoral ligaments, morphometric analysis, Thiel embalmed knees, knee arthroplasty

Procedia PDF Downloads 333
792 Pull-In Instability Determination of Microcapacitive Sensor for Measuring Special Range of Pressure

Authors: Yashar Haghighatfar, Shahrzad Mirhosseini

Abstract:

Pull-in instability is a nonlinear and crucial effect that is important for the design of microelectromechanical system devices. In this paper, the appropriate electrostatic voltage range is determined by measuring fluid flow pressure via micro pressure sensor based microbeam. The microbeam deflection contains two parts, the static and perturbation deflection of static. The second order equation regarding the equivalent stiffness, mass and damping matrices based on Galerkin method is introduced to predict pull-in instability due to the external voltage. Also the reduced order method is used for solving the second order nonlinear equation of motion. Furthermore, in the present study, the micro capacitive pressure sensor is designed for measuring special fluid flow pressure range. The results show that the measurable pressure range can be optimized, regarding damping field and external voltage.

Keywords: MEMS, pull-in instability, electrostatically actuated microbeam, reduced order method

Procedia PDF Downloads 199
791 Lateral Cephalometric Radiograph to Determine Sex in Forensic Investigations

Authors: Paulus Maulana

Abstract:

Forensic identification is to help investigators determine a person's identity. Personal identification is often a problem in civil and criminal cases. Orthodontists like all other dental professionals can play a major role by maintaining lateral cephalogram and thus providing important or vital information or can clues to the legal authorities in order to help them in their search. Radiographic lateral cephalometry is a measurement method which focused on the anatomical points of human lateral skull. Sex determination is one of the most important aspects of the personal identification in forensic. Lateral cephalogram is a valuable tool in identification of sex as reveal morphological details of the skull on single radiograph. This present study evaluates the role of lateral cephalogram in identification of sex that parameters of lateral cephalogram are linear measurement and angle measurement. The linear measurements are N-S ( Anterior cranial length), Sna-Snp (Palatal plane length), Me-Go (menton-gonion), N-Sna ( Midfacial anterior height ), Sna-Me (Lower anterior face height), Co-Gn (total mandibular length). The angle measurements are SNA, SNB, ANB, Gonial, Interincical, and facial.

Keywords: lateral cephalometry, cephalogram, sex, forensic, parameter

Procedia PDF Downloads 170
790 Clinical Outcomes and Surgical Complications in Patients with Cervical Disk Degeneration

Authors: Mirzashahi Babak, Mansouri Pejman, Najafi Arvin, Farzan Mahmoud

Abstract:

Introduction: There are several surgical treatment choices for cervical spondylotic myelopathy (CSM). The aim of this study is to evaluate clinical outcomes and surgical complications in patients with cervical disk degeneration (CDD) undergoing either anterior cervical discectomy with or without fusion or cervical laminectomy and fusion. Methods: This prospective case series study included 45 consecutive patients with cervical spondylotic myelopathy between January 2010 and November 2014. There were 28 males and 17 females, with a mean age of 47 (range 37-68) years. The mean clinical follow-up was 14 months (range 3-24 months). The Neck Disability Index (NDI), visual analog scale (VAS) neck and arm pain, Short Form-36 (SF-36) were used as the functional outcome measurements. All of the complications in our patients were recorded. Results: In our study group, 26 patients underwent only one or two level anterior cervical discectomy. Ten patients underwent anterior cervical discectomy and fusion (ACDF) and nine cases underwent posterior laminectomy and fusion. We have found a statistically significant improvement between mean preoperative (29, range 19-43) and postoperative (7, range 0-12) NDI scores following surgery (P < 0.05). Also, there was a statistically significant difference between pre and post-operative VAS and SF-36 score (p < 0.05). There was a 7% overall complication rate (n = 3). The only complication in our patients was surgical site cellulitis which has been managed with oral antibiotic therapy. Conclusion: Both anterior cervical discectomy with or without fusion or posterior laminectomy and fusion are safe and efficacious treatment options for the management of CSM. The clinical outcomes seem to be fairly reproducible.

Keywords: cervical, myelopathy, discectomy, fusion, laminectomy

Procedia PDF Downloads 321
789 One-Dimensional Numerical Simulation of the Nonlinear Instability Behavior of an Electrified Viscoelastic Liquid Jet

Authors: Fang Li, Xie-Yuan Yin, Xie-Zhen Yin

Abstract:

Instability and breakup of electrified viscoelastic liquid jets are involved in various applications such as inkjet printing, fuel atomization, the pharmaceutical industry, electrospraying, and electrospinning. Studying on the instability of electrified viscoelastic liquid jets is of theoretical and practical significance. We built a one-dimensional electrified viscoelastic model to study the nonlinear instability behavior of a perfecting conducting, slightly viscoelastic liquid jet under a radial electric field. The model is solved numerically by using an implicit finite difference scheme together with a boundary element method. It is found that under a radial electric field a viscoelastic liquid jet still evolves into a beads-on-string structure with a thin filament connecting two adjacent droplets as in the absence of an electric field. A radial electric field exhibits limited influence on the decay of the filament thickness in the nonlinear evolution process of a viscoelastic jet, in contrast to its great enhancing effect on the linear instability of the jet. On the other hand, a radial electric field can induce axial non-uniformity of the first normal stress difference within the filament. Particularly, the magnitude of the first normal stress difference near the midpoint of the filament can be greatly decreased by a radial electric field. Decreasing the extensional stress by a radial electric field may found applications in spraying, spinning, liquid bridges and others. In addition, the effect of a radial electric field on the formation of satellite droplets is investigated on the parametric plane of the dimensionless wave number and the electrical Bond number. It is found that satellite droplets may be formed for a larger axial wave number at a larger radial electric field. The present study helps us gain insight into the nonlinear instability characteristics of electrified viscoelastic liquid jets.

Keywords: non linear instability, one-dimensional models, radial electric fields, viscoelastic liquid jets

Procedia PDF Downloads 360
788 Anterior Tooth Misalignment: Orthodontics or Restorative Treatment

Authors: Maryam Firouzmandi, Moosa Miri

Abstract:

Smile is considered to be one of the most effective methods of influencing people. Increasing numbers of patients are requesting cosmetic dental procedures to achieve the perfect smile. Based on the patient’s age, oral and facial characteristics, and the dentist’s expertise, different concepts of treatment would be available. Orthodontics is the most conservative and the ideal treatment alternative for crowded anterior teeth; however, it may be rejected by patients due to occupational limitations of time, physical discomfort including pain and functional limitations, psychological discomfort, and appearance during treatment. In addition, orthodontic treatment will not resolve deficits of contour and color of the anterior teeth. In consequence, patients may demand restorative techniques to resolve their anterior mal-alignment instead, often called "instant orthodontics". Following its introduction, however, adhesive dentistry has suffered at times from overuse. Creating short-term attractive smiles at the expense of long-term dental health and optimal tooth biomechanics by using cosmetic techniques should not be considered an ethical approach. The objective of this narrative review was to investigate the literature for guidelines with regard to decision making and treatment planning for anterior tooth mal-alignment. In this regard, indications of orthodontic, restorative, combination of both treatments, and adjunctive periodontal surgery were discussed in clinical cases to achieve a proportional smile. Restorative modalities would include disking, cosmetic contouring, veneers, and crowns and were compared with limited or comprehensive orthodontic options. A rapid review was also presented on pros and cons of snap on smile to mask malalignments. Diagnostic tools such as mock up, wax up, and digital smile design were also considered to achieve more conservative and functional treatments with respect to biologic factors.

Keywords: crowding, misalignment, veneer, crown, orthodontics

Procedia PDF Downloads 93
787 Normal Meniscal Extrusion Using Ultrasonography during the Different Range of Motion Running Head: Sonography for Meniscal Extrusion

Authors: Arash Sharafat Vaziri, Leila Aghaghazvini, Soodeh Jahangiri, Mohammad Tahami, Roham Borazjani, Mohammad Naghi Tahmasebi, Hamid Rabie, Hesan Jelodari Mamaghani, Fardis Vosoughi, Maryam Salimi

Abstract:

Aims: It is essential to know the normal extrusion measures in order to detect pathological ones. In this study, we aimed to define some normal reference values for meniscal extrusion in the normal knees during different ranges of motion. Methods: The amount of anterior and posterior portion of meniscal extrusion among twenty-one asymptomatic volunteers (42 knees) were tracked at 0, 45, and 90 degrees of knee flexion using an ultrasound machine. The repeated measures analysis of variance (ANOVA) was used to show the interaction between the amounts of meniscal extrusion and the different degrees of knee flexion. Result: The anterior portion of the lateral menisci at full knee extension (0.59±1.40) and the posterior portion of the medial menisci during 90° flexion (3.06±2.36) showed the smallest and the highest mean amount of extrusion, respectively. The normal average amounts of anterior extrusion were 1.12± 1.17 mm and 0.99± 1.34 mm for medial and lateral menisci, respectively. The posterior meniscal normal extrusions were significantly increasing in both medial and lateral menisci during the survey (F= 20.250 and 11.298; both P-values< 0.001) as they were measured at 2.37± 2.16 mm and 1.53± 2.18 mm in order. Conclusion: The medial meniscus can extrude 1.74± 1.84 mm normally, while this amount was 1.26± 1.82 mm for the lateral meniscus. These measures commonly increased with the rising of knee flexion motion. Likewise, the posterior portion showed more extrusion than the anterior portion on both sides. These measures commonly increased with higher knee flexion.

Keywords: meniscal extrusion, ultrasonography, knee

Procedia PDF Downloads 68
786 The Success Rate of Anterior Crowding Orthodontic Treatment Using Removable Appliances

Authors: Belly Yordan

Abstract:

Orthodontic treatment can be done by using the fix and removable orthodontic appliance. The success of treatment depends on the patient’s age, the type of malocclusion, treatment of space discrepancy, patient’s oral hygiene, operator skills, and patient cooperation. This case report was aimed to show the success of orthodontic treatment in patients with skeletal class I relationship, class I angle dental malocclusion with anterior crowding and rotation by using a removable appliance with modification. The removable appliance used is standard with removable plate components such as passive clasp (Adam’s hook clasp) accompanied with some active clasps (labial bow, some springs, etc.). A button is used as an additional tool or combined with other tools to correct tooth in rotated position. The results obtained by the success of treatments which is shown in pre and post-treatment photos, the overjet was reduced, the arch form became normal, the tooth malposition became normal, and rotation was corrected. Facial profile appearance of the patient is getting better, and the dental coordination also became better. This case report is to prove that treatment with the removable appliance is quite successful with the robust wearing of appropriate retainers.

Keywords: success rate, anterior crowding, orthodontic treatment, removable appliances

Procedia PDF Downloads 143
785 Effect of Clinical Parameters on Strength of Reattached Tooth Fragment in Anterior Teeth: Systematic Review and Meta-Analysis

Authors: Neeraj Malhotra, Ramya Shenoy

Abstract:

Objective: To assess the effect of clinical parameters (bonding agent, preparation design & storage media) on the strength of reattached anterior tooth fragment. Methodology: This is a systematic review and meta-analysis for articles referred from MEDLINE, PUBMED, and GOOGLE SCHOLAR. The articles on tooth reattachment and clinical factors affecting fracture strength/bond strength/fracture resistance of the reattached tooth fragment in anterior teeth and published in English from 1999 to 2016 were included for final review. Results: Out of 120 shortlisted articles, 28 articles were included for the systematic review and meta-analysis based on 3 clinical parameters i.e. bonding agent, tooth preparation design & storage media. Forest plot & funnel plots were generated based on individual clinical parameter and their effect on strength of reattached anterior tooth fragment. Results based on analysis suggest combination of both conclusive evidence favoring the experimental group as well as in-conclusive evidence for individual parameter. Conclusion: There is limited evidence as there are fewer articles supporting each parameter in human teeth. Bonding agent had showed better outcome in selected studies.

Keywords: bonding agent, bond strength, fracture strength, preparation design, reattachment, storage media

Procedia PDF Downloads 152
784 Effect of Muscle Energy Technique on Anterior Pelvic Tilt in Lumbar Spondylosis Patients

Authors: Enas El Sayed Abutaleb, Mohamed Taher Eldesoky, Shahenda Abd El Rasol

Abstract:

Background: Muscle energy techniques (MET) have been widely used by manual therapists over the past years, but still limited research validated its use and there was limited evidence to substantiate the theories used to explain its effects. Objective: To investigate the effect of muscle energy technique (MET) on anterior pelvic tilt in patients with lumbar spondylosis. Design: Randomized controlled trial. Subjects: Thirty patients with anterior pelvic tilt from both sexes were involved, aged between 35 to 50 years old and they were divided into MET and control groups with 15 patients in each. Methods: All patients received 3 sessions/week for 4 weeks where the study group received MET, Ultrasound and Infrared, and the control group received U.S and I.R only. Pelvic angle was measured by palpation meter, pain severity by the visual analogue scale and functional disabilities by the Oswestry disability index. Results: Both groups showed significant improvement in all measured variables. The MET group was significantly better than the control group in pelvic angle, pain severity, and functional disability as p-value were (0.001, 0.0001, 0.0001) respectively. Conclusion and implication: The study group fulfilled greater improvement in all measured variables than the control group which implies that application of MET in combination with U.S and I.R were more effective in improving pelvic tilting angle, pain severity and functional disabilities than using electrotherapy only.

Keywords: anterior pelvic tilt, lumbar spondylosis, muscle energy technique exercise, pelvic tilting angle

Procedia PDF Downloads 354
783 Association between Bottle-Feeding Habit and Occlusal Disorders in Children 4-6 Years Old

Authors: Roberta S. Ilinsky, Livia Eisler, Gustavo Mota, Kurt Faltin Jr., Cristina Lucia Feijó Ortolani

Abstract:

The aim of the present study was to evaluate the presence of occlusal disorders associated with bottle feeding habits in children aged 4-6 years old. A cross-sectional study was performed in a sample of 466 preschool children aged 4-6 years, attending state preschools in the city of Sao Paulo, Brazil. Parents and caregivers answered a questionnaire about children’s oral habits, including bottle-feeding habit, and signed the Informed Consent form. The students underwent an oral examination to evaluate occlusal disorders. Data were analyzed by the SPSS 2.2 program (IBM, USA) and treated with non-parametric chi-square tests and multiple logistic regression with a significance level of p < 0.05. There was association between bottle-feeding and occlusal disorders (OR = 3.058, 95% CI = 1.561-5.991, PI < 0.001), with a higher significance for anterior open bite (OR = 2.855, 95% CI = 1.769-4.606, PI < 0.001) and canine class II (OR = 0.667, 95% CI = 0.449-0.990, PI < 0.045). There was no relationship between bottle-feeding habit and other occlusal disorders examined. It was possible to conclude that children who were bottle fed during childhood are more likely to develop occlusal disorders, especially anterior open bite and canine class II.

Keywords: anterior open-bite, bottle-feeding, habits, malocclusion

Procedia PDF Downloads 142
782 Effect of Design Parameters on Porpoising Instability of a High Speed Planing Craft

Authors: Lokeswara Rao P., Naga Venkata Rakesh N., V. Anantha Subramanian

Abstract:

It is important to estimate, predict, and avoid the dynamic instability of high speed planing crafts. It is known that design parameters like relative location of center of gravity with respect to the dynamic lift centre and length to beam ratio of the craft have influence on the tendency to porpoise. This paper analyzes the hydrodynamic performance on the basis of the semi-empirical Savitsky method and also estimates the same by numerical simulations based on Reynolds Averaged Navier Stokes (RANS) equations using a commercial code namely, STAR- CCM+. The paper examines through the same numerical simulation considering dynamic equilibrium, the changing running trim, which results in porpoising. Some interesting results emerge from the study and this leads to early detection of the instability.

Keywords: CFD, planing hull, porpoising, Savitsky method

Procedia PDF Downloads 153
781 Comparison of Trunk and Hip Muscle Activities and Anterior Pelvic Tilt Angle during Three Different Bridging Exercises in Subjects with Chronic Low Back Pain

Authors: Da-Eun Kim, Heon-Seock Cynn, Sil-Ah Choi, A-Reum Shin

Abstract:

Bridging exercise in supine position with the hips and knees flexed have been commonly performed as one of the therapeutic exercises and is a comfortable and pain-free position to most individuals with chronic low back pain (CLBP). Many previous studies have investigated the beneficial way of performing bridging exercises to improve activation of abdominal and gluteal muscle and reduce muscle activity of hamstrings (HAM) and erector spinae (ES) and compensatory lumbopelvic motion. The purpose of this study was to compare the effects of three different bridging exercises on the HAM, ES, gluteus maximus (Gmax), gluteus medius (Gmed), and transverse abdominis/internal abdominis oblique (TrA/IO) activities and anterior pelvic tilt angle in subjects with CLBP. Seventeen subjects with CLBP participated in this study. They performed bridging under three different conditions (with 30° hip abduction, isometric hip abduction, and isometric hip adduction). Surface electromyography was used to measure muscle activity, and the ImageJ software was used to calculate anterior pelvic tilt angle. One-way repeated-measures analysis of variance was used to assess the statistical significance of the measured variables. HAM activity was significantly lower in bridging with 30° hip abduction and isometric hip abduction than in bridging with isometric hip adduction. Gmax and Gmed activities were significantly greater in bridging with isometric hip abduction than in bridging with 30° hip abduction and isometric hip adduction. TrA/IO muscle activity was significantly greater and anterior pelvic tilt angle was significantly lower in bridging with isometric hip adduction than in bridging with 30° hip abduction and isometric hip abduction. Bridging with isometric hip abduction using Thera-Band can effectively reduce HAM activity, and increase Gmax and Gmed activities in subjects with CLBP. Bridging with isometric hip adduction using a pressure biofeedback unit can be a beneficial exercise to improve TrA/IO activity and minimize anterior pelvic tilt in subjects with CLBP.

Keywords: bridging exercise, electromyography, low back pain, lower limb exercise

Procedia PDF Downloads 189
780 Analysis of Two-Phase Flow Instabilities in Conventional Channel of Nuclear Power Reactor

Authors: M. Abdur Rashid Sarkar, Riffat Mahmud

Abstract:

Boiling heat transfer plays a crucial role in cooling nuclear reactor for safe electricity generation. A two phase flow is susceptible to thermal-hydrodynamic instabilities, which may cause flow oscillations of constant amplitude or diverging amplitude. These oscillations may induce boiling crisis, disturb control systems, or cause mechanical damage. Based on their mechanisms, various types of instabilities can be classified for a nuclear reactor. From a practical engineering point of view one of the major design difficulties in dealing with multiphase flow is that the mass, momentum, and energy transfer rates and processes may be quite sensitive to the geometric configuration of the heat transfer surface. Moreover, the flow within each phase or component will clearly depend on that geometric configuration. The complexity of this two-way coupling presents a major challenge in the study of multiphase flows and there is much that remains to be done. Yet, the parametric effects on flow instability such as the effect of aspect ratio, pressure drop, channel length, its orientation inlet subcooling and surface roughness etc. have been analyzed. Another frequently occurring instability, known as the Kelvin–Helmholtz instability has been briefly reviewed. Various analytical techniques for predicting parametric effect on the instability are analyzed in terms of their applicability and accuracy.

Keywords: two phase flows, boiling crisis, thermal-hydrodynamic instabilities, water cooled nuclear reactors, kelvin–helmholtz instability

Procedia PDF Downloads 369
779 Origin Variability of Superior Vesical Artery

Authors: Waseem Al-Talalwah

Abstract:

The superior vesical artery usually arises directly from the anterior division of the internal iliac artery. It may arise from the umbilical artery as three or four branches to supply the upper and middle parts of bladder. Current study focuses on the different origins of the superior vesical artery to provide a sufficient data for surgeons to disease iatrogenic fault. The superior vesical artery arises directly from the anterior division of the internal iliac artery in 24.5% whereas it arises indirectly as from umbilical artery in 83.7%. Further, it may arise from any branch of the anterior division as from the utrine and obturator arteries in 6.1% and in 6.3% respectively. It also shares the origin of the internal pudendal and inferior glutyeal artery as it arises from the gluteopudendal trunk in 4.1%. The superior vesical artery arises as a single, double, triple and quadruple in 69.4%, 20.4%, 8.2% and 2% respectively. In case of cystectomy for bladder cancer, surgeons have to be aware of the origin variability of superior vesical artery to prevent post-surgical complication such as intra-pelvic bleeding. Also, the as intra-pelvic bleeding has to be expected in case of hysterectomy therefore a great caution of the vesical branches arising from uterine artery has to be considered. In case of aneurysm resection of inferior gluteal artery arising from the gluteopudendal trunk, the surgeons have to be careful of the vascular supply of urinary bladder coming from above and below this common trunk as from superior and inferior vesical arteries respectively. Therefore, present study increases the awareness of clinical significance of superior vesical artery origin for surgeons to minimise the iatroginc errors.

Keywords: superior vesical artery, anterior division, internal iliac, internal pudendal, inferior glutyeal, intra-pelvic bleeding, hysterectomy, cystectomy

Procedia PDF Downloads 362
778 Orthodontic Treatment Using CAD/CAM System

Authors: Cristiane C. B. Alves, Livia Eisler, Gustavo Mota, Kurt Faltin Jr., Cristina L. F. Ortolani

Abstract:

The correct positioning of the brackets is essential for the success of orthodontic treatment. Indirect bracket placing technique has the main objective of eliminating the positioning errors, which commonly occur in the technique of direct system of brackets. The objective of this study is to demonstrate that the exact positioning of the brackets is of extreme relevance for the success of the treatment. The present work shows a case report of an adult female patient who attended the clinic with the complaint of being in orthodontic treatment for more than 5 years without noticing any progress. As a result of the intra-oral clinical examination and documentation analysis, a class III malocclusion, an anterior open bite, and absence of all third molars and first upper and lower bilateral premolars were observed. For the treatment, the indirect bonding technique with self-ligating ceramic braces was applied. The preparation of the trays was done after the intraoral digital scanning and printing of models with a 3D printer. Brackets were positioned virtually, using a specialized software. After twelve months of treatment, correction of the malocclusion was observed, as well as the closing of the anterior open bite. It is concluded that the adequate and precise positioning of brackets is necessary for a successful treatment.

Keywords: anterior open-bite, CAD/CAM, orthodontics, malocclusion, angle class III

Procedia PDF Downloads 151
777 Xenografts: Successful Penetrating Keratoplasty Between Two Species

Authors: Francisco Alvarado, Luz Ramírez

Abstract:

Corneal diseases are one of the main causes of visual impairment and affect almost 4 million, and this study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. No patient was observed with clinical graft rejection. Among the cases: 2 were positive to fungal culture, 2 with Aspergillus and the other 8 cases were confirmed by bacteriological culture. Corneal diseases are one of the main causes of visual impairment and affect almost 4 million. This study assesses the effects of deep anterior lamellar keratoplasty (DALK) with porcine corneal stroma and postoperative topical treatment with tacrolimus in patients with infectious keratitis. Receiver bed diameters ranged from 7.00 to 9.00 mm. No incidents of Descemet's membrane perforation were observed during surgery. During the follow-up period, no corneal graft splitting, IOP increase, or intolerance to tacrolimus were observed. Deep anterior lamellar keratoplasty seems to be the best option to avoid xenograft rejection, and it could help new surgical techniques in humans.

Keywords: ophthalmology, cornea, corneal transplant, xenografts, surgical innovations

Procedia PDF Downloads 57
776 An Electromyographic Study of Muscle Coordination during Dynamic Glenohumeral Joint Elevation

Authors: Omid Khaiyat, David Hawkes

Abstract:

Introduction: There remains a lack of information on sophisticated coordination patterns across shoulder girdle muscles. Considering the stability of the shoulder being heavily dependent on coordinated muscle activity during its wide-ranging movements, it is important that key intermuscular relationships are well-defined for a better understanding of underlying pathology. This study investigated shoulder intermuscular coordination during different planes of shoulder elevation. Materials and Methods: EMG was recorded from 14 shoulder muscles in 20 healthy participants during shoulder flexion, scapula plane elevation, abduction, and extension. Cross-correlation by means of Pearson Correlation Coefficient (PCC) was used to examine the coordination between different muscles and muscle groups. Results: Coordination between rotator cuff and deltoid muscle groups was significantly higher (p =0.020-0.035) during the initial (PCC) = 0.79) and final (PCC = 0.74) phases of elevation compared to the mid-range (PCC = 0.34). Furthermore, a high level of coordination (PCC = 0.89) was noted between the deltoid group and the adductor group (latissimus dorsi and teres major) during the initial stage of shoulder elevation. Conclusion: The destabilising force of the deltoid during the initial stage of shoulder elevation is balanced by coordinated activity of rotator cuff, latissimus dorsi, and teres major. This is also the case for the end-range of movement, where increased demand for stability again leads to higher coordination between the deltoid and rotator cuff muscle groups. Appreciation of the sophistication of normal shoulder function evidence-based rehabilitation strategies for conditions such as subacromial impingement syndrome or shoulder instability can be developed.

Keywords: shoulder, coordination, EMG, muscle activity, upper limb

Procedia PDF Downloads 139
775 Thermal Instability in Solid under Irradiation

Authors: P. Selyshchev

Abstract:

Construction materials for nuclear facilities are operated under extreme thermal and radiation conditions. First of all, they are nuclear fuel, fuel assemblies, and reactor vessel. It places high demands on the control of their state, stability of their state, and their operating conditions. An irradiated material is a typical example of an open non-equilibrium system with nonlinear feedbacks between its elements. Fluxes of energy, matter and entropy maintain states which are far away from thermal equilibrium. The links that arise under irradiation are inherently nonlinear. They form the mechanisms of feed-backs that can lead to instability. Due to this instability the temperature of the sample, heat transfer, and the defect density can exceed the steady-state value in several times. This can lead to change of typical operation and an accident. Therefore, it is necessary to take into account the thermal instability to avoid the emergency situation. The point is that non-thermal energy can be accumulated in materials because irradiation produces defects (first of all these are vacancies and interstitial atoms), which are metastable. The stored energy is about energy of defect formation. Thus, an annealing of the defects is accompanied by releasing of non-thermal stored energy into thermal one. Temperature of the material grows. Increase of temperature results in acceleration of defect annealing. Density of the defects drops and temperature grows more and more quickly. The positive feed-back is formed and self-reinforcing annealing of radiation defects develops. To describe these phenomena a theoretical approach to thermal instability is developed via formalism of complex systems. We consider system of nonlinear differential equations for different components of microstructure and temperature. The qualitative analysis of this non-linear dynamical system is carried out. Conditions for development of instability have been obtained. Points of bifurcation have been found. Convenient way to represent obtained results is a set of phase portraits. It has been shown that different regimes of material state under irradiation can develop. Thus degradation of irradiated material can be limited by means of choice appropriate kind of evolution of materials under irradiation.

Keywords: irradiation, material, non-equilibrium state, nonlinear feed-back, thermal instability

Procedia PDF Downloads 244
774 The Orthodontic Management of Multiple Tooth Agenesis with Macroglossia in Adult Patient: Case Report

Authors: Yanuarti Retnaningrum, Cendrawasih A. Farmasyanti, Kuswahyuning

Abstract:

Orthodontists find challenges in treating patients who have cases of macroglossia and multiple tooth agenesis because difficulties in determining the causes, formulating a diagnosis and the potential for relapse after treatment. Definition of macroglossia is a tongue enlargement due to muscle hypertrophy, tumor or an endocrine disturbance. Macroglossia may cause many problems such as anterior proclination of upper and lower incisors, development of general diastema and anterior and/ or posterior open bite. Treatment for such patients with multiple tooth agenesis and macroglossia can be complex and must consider orthodontic and/or surgical interventions. This article discusses an orthodontic non surgical approach to a patient with a general diastema in both maxilla and mandible associated with multiple tooth agenesis and macroglossia. Fixed orthodontic therapy with straightwire appliance was used for space closure in anterior region of maxilla and mandible, also to create a space suitable for future prosthetic restoration. After 12 months treatment, stable and functional occlusal relationships was achieved, although still have edentulous area in both maxilla and mandible. At the end of the orthodontic treatment was obtained with correct overbite and overjet values. After removal of the brackets, a maxillary and mandibular removable retainer combine with artificial tooth were placed for retention.

Keywords: general diastema, macroglossia, space closure, tooth agenesis

Procedia PDF Downloads 156