Search results for: Pelviureteric Junction (PUJ) Obstruction
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 312

Search results for: Pelviureteric Junction (PUJ) Obstruction

222 Epidemiology and Jeopardy Aspect of Febrile Neutropenia Patients by Means of Infectious Maladies

Authors: Pouya Karimi, Ramin Ghasemi Shayan

Abstract:

Conclusions of the sort and setting of observational treatment for immunocompromised patients with fever are confused by the qualities of the hidden disease and the impacts of medications previously got, just as by changing microbiological examples and patterns in sedate obstruction at national and institutional levels. A few frameworks have been proposed to recognize patients who could profit by outpatient anti-infection treatment from patients who require hospitalization. Useful contemplations may choose whether the fundamental checking during the time of neutropenia can be accomplished.

Keywords: microbiology, infectious, neutropenia, epidemiology

Procedia PDF Downloads 124
221 Finite Element Approach to Evaluate Time Dependent Shear Behavior of Connections in Hybrid Steel-PC Girder under Sustained Loading

Authors: Mohammad Najmol Haque, Takeshi Maki, Jun Sasaki

Abstract:

Headed stud shear connections are widely used in the junction or embedded zone of hybrid girder to achieve whole composite action with continuity that can sustain steel-concrete interfacial tensile and shear forces. In Japan, Japan Road Association (JRA) specifications are used for hybrid girder design that utilizes very low level of stud capacity than those of American Institute of Steel Construction (AISC) specifications, Japan Society of Civil Engineers (JSCE) specifications and EURO code. As low design shear strength is considered in design of connections, the time dependent shear behavior due to sustained external loading is not considered, even not fully studied. In this study, a finite element approach was used to evaluate the time dependent shear behavior for headed studs used as connections at the junction. This study clarified, how the sustained loading distinctively impacted on changing the interfacial shear of connections with time which was sensitive to lodging history, positions of flanges, neighboring studs, position of prestress bar and reinforcing bar, concrete strength, etc. and also identified a shear influence area. Stud strength was also confirmed through pushout tests. The outcome obtained from the study may provide an important basis and reference data in designing connections of hybrid girders with enhanced stud capacity with due consideration of their long-term shear behavior.

Keywords: finite element, hybrid girder, shear connections, sustained loading, time dependent behavior

Procedia PDF Downloads 100
220 Optimal Approach for Siewert Type Ⅱ Adenocarcinoma of the Esophagogastric Junction: A Systematic Review and Metanalysis

Authors: Maatouk Mohamed, Nouira Mariem

Abstract:

Background and aims: Healthcare-associated infections (HAI) represent a major public health problem worldwide. They represent one of the most serious adverse events in health care. The objectives of our study were to estimate the prevalence of HAI at the Charles Nicolle Hospital (CNH) and to identify the main associated factors as well as to estimate the frequency of antibiotic use. Methods: It was a cross sectional study at the CNH with a unique passage per department (OctoberDecember 2018). All patients present at the wards for more than 48 hours were included. All patients from outpatient consultations, emergency and dialysis departments were not included. The site definitions of infections proposed by the Centers for Disease Control and Prevention (CDC) were used. Only clinically and/or microbiologically confirmed active HAIs were included. Results: A total of 318 patients were included with a mean age of 52 years and a sex ratio (Female/Male) of 1.05. A total of 41 patients had one or more active HAIs, corresponding to a prevalence of 13.1% (95% CI: 9.3%-16.9%). The most frequent sites infections were urinary tract infections and pneumonia. Multivariate analysis among adult patients (>=18 years) (n=261), revealed that infection on admission (p=0.01), alcoholism (p=0.01), high blood pressure (p=0.008), having at least one invasive device inserted (p=0.004), and history of recent surgery (p=0.03), increased significantly the risk of HAIs. More than 1 of 3 patients (35.4%) were under antibiotics on the day of the survey, of which more than half (57.4%) were under 2 or more types of antibiotics. Conclusion: The prevalence of HAIs and antibiotic prescriptions at the CNH were considerably high. An infection prevention and control committee, as well as the development of an Antibiotic stewardship program with continuous monitoring using repeated prevalence surveys must be implemented to limit the frequency of these infections effectively.

Keywords: tumors, oesophagectomy, esophagogastric junction, systematic review

Procedia PDF Downloads 48
219 A Three-Dimensional TLM Simulation Method for Thermal Effect in PV-Solar Cells

Authors: R. Hocine, A. Boudjemai, A. Amrani, K. Belkacemi

Abstract:

Temperature rising is a negative factor in almost all systems. It could cause by self heating or ambient temperature. In solar photovoltaic cells this temperature rising affects on the behavior of cells. The ability of a PV module to withstand the effects of periodic hot-spot heating that occurs when cells are operated under reverse biased conditions is closely related to the properties of the cell semi-conductor material. In addition, the thermal effect also influences the estimation of the maximum power point (MPP) and electrical parameters for the PV modules, such as maximum output power, maximum conversion efficiency, internal efficiency, reliability, and lifetime. The cells junction temperature is a critical parameter that significantly affects the electrical characteristics of PV modules. For practical applications of PV modules, it is very important to accurately estimate the junction temperature of PV modules and analyze the thermal characteristics of the PV modules. Once the temperature variation is taken into account, we can then acquire a more accurate MPP for the PV modules, and the maximum utilization efficiency of the PV modules can also be further achieved. In this paper, the three-Dimensional Transmission Line Matrix (3D-TLM) method was used to map the surface temperature distribution of solar cells while in the reverse bias mode. It was observed that some cells exhibited an inhomogeneity of the surface temperature resulting in localized heating (hot-spot). This hot-spot heating causes irreversible destruction of the solar cell structure. Hot spots can have a deleterious impact on the total solar modules if individual solar cells are heated. So, the results show clearly that the solar cells are capable of self-generating considerable amounts of heat that should be dissipated very quickly to increase PV module's lifetime.

Keywords: thermal effect, conduction, heat dissipation, thermal conductivity, solar cell, PV module, nodes, 3D-TLM

Procedia PDF Downloads 355
218 Clinical and Radiological Features of Adenomyosis and Its Histopathological Correlation

Authors: Surabhi Agrawal Kohli, Sunita Gupta, Esha Khanuja, Parul Garg, P. Gupta

Abstract:

Background: Adenomyosis is a common gynaecological condition that affects the menstruating women. Uterine enlargement, dysmenorrhoea, and menorrhagia are regarded as the cardinal clinical symptoms of adenomyosis. Classically it was thought, compared with ultrasonography, when adenomyosis is suspected, MRI enables more accurate diagnosis of the disease. Materials and Methods: 172 subjects were enrolled after an informed consent that had complaints of HMB, dyspareunia, dysmenorrhea, and chronic pelvic pain. Detailed history of the enrolled subjects was taken, followed by a clinical examination. These patients were then subjected to TVS where myometrial echo texture, presence of myometrial cysts, blurring of endomyometrial junction was noted. MRI was followed which noted the presence of junctional zone thickness and myometrial cysts. After hysterectomy, histopathological diagnosis was obtained. Results: 78 participants were analysed. The mean age was 44.2 years. 43.5% had parity of 4 or more. heavy menstrual bleeding (HMB) was present in 97.8% and dysmenorrhea in 93.48 % of HPE positive patient. Transvaginal sonography (TVS) and MRI had a sensitivity of 89.13% and 80.43%, specificity of 90.62% and 84.37%, positive likelihood ratio of 9.51 and 5.15, negative likelihood ratio of 0.12 and 0.23, positive predictive value of 93.18% and 88.1%, negative predictive value of 85.29% and 75% and a diagnostic accuracy of 89.74% and 82.5%. Comparison of sensitivity (p=0.289) and specificity (p=0.625) showed no statistically significant difference between TVS and MRI. Conclusion: Prevalence of 30.23%. HMB with dysmenorrhoea and chronic pelvic pain helps in diagnosis. TVS (Endomyometrial junction blurring) is both sensitive and specific in diagnosing adenomyosis without need for additional diagnostic tool. Both TVS and MRI are equally efficient, however because of certain additional advantages of TVS over MRI, it may be used as the first choice of imaging. MRI may be used additionally in difficult cases as well as in patients with existing co-pathologies.

Keywords: adenomyosis, heavy menstrual bleeding, MRI, TVS

Procedia PDF Downloads 457
217 An Investigation on the Suitability of Dual Ion Beam Sputtered GMZO Thin Films: For All Sputtered Buffer-Less Solar Cells

Authors: Vivek Garg, Brajendra S. Sengar, Gaurav Siddharth, Nisheka Anadkat, Amitesh Kumar, Shailendra Kumar, Shaibal Mukherjee

Abstract:

CuInGaSe (CIGSe) is the dominant thin film solar cell technology. The band alignment of Buffer/CIGSe interface is one of the most crucial parameters for solar cell performance. In this article, the valence band offset (VBOff) and conduction band offset (CBOff) values of Cu(In0.70Ga0.30)Se/ 1 at.% Ga: Mg0.25Zn0.75O (GMZO) heterojunction, grown by dual ion beam sputtering system (DIBS), are calculated to understand the carrier transport mechanism at the heterojunction for the realization of all sputtered buffer-less solar cells. To determine the valence band offset (VBOff), ∆E_V at GMZO/CIGSe heterojunction interface, the standard method based on core-level photoemission is utilized. The value of ∆E_V can be evaluated by considering common core-level peaks. In our study, the values of (Valence band onset)VBOn, obtained by linear extrapolation method for GMZO and CIGSe films are calculated to be 2.86 and 0.76 eV. In the UPS spectra peak positions of Se 3d is observed in UPS spectra at 54.82 and 54.7 eV for CIGSe film and GMZO/CIGSe interface respectively, while the peak position of Mg 2p is observed at 50.09 and 50.12 eV for GMZO and GMZO/CIGSe interface respectively. The optical band gap of CIGSe and GMZO are obtained from absorption spectra procured from spectroscopic ellipsometry are 1.26 and 3.84 eV respectively. The calculated average values of ∆E_v and ∆E_C are estimated to be 2.37 and 0.21 eV, respectively, at room temperature. The calculated positive conduction band offset termed as a spike at the absorber junction is the required criterion for the high-efficiency solar cells for the efficient charge extraction from the junction. So we can conclude that the above study confirms GMZO thin films grown by the dual ion beam sputtering system are the suitable candidate for the CIGSe thin films based ultra-thin buffer-less solar cells. We investigated the band-offset properties at the GMZO/CIGSe heterojunction to verify the suitability of the GMZO for the realization of the buffer-less solar cells. The calculated average values of ∆E_V and ∆E_C are estimated to be 2.37 and 0.21 eV, respectively, at room temperature. The calculated positive conduction band offset termed as a spike at the absorber junction is the required criterion for the high-efficiency solar cells for the efficient charge extraction from the junction. So we can conclude that the above study confirms GMZO thin films grown by the dual ion beam sputtering system are the suitable candidate for the CIGSe thin films based ultra-thin buffer-less solar cells. Acknowledgment: We are thankful to DIBS, EDX, and XRD facility equipped at Sophisticated Instrument Centre (SIC) at IIT Indore. The authors B.S.S and A.K acknowledge CSIR and V.G acknowledge UGC, India for their fellowships. B.S.S is thankful to DST and IUSSTF for BASE Internship Award. Prof. Shaibal Mukherjee is thankful to DST and IUSSTF for BASE Fellowship and MEITY YFRF award. This work is partially supported by DAE BRNS, DST CERI, and DST-RFBR Project under India-Russia Programme of Cooperation in Science and Technology. We are thankful to Mukul Gupta for SIMS facility equipped at UGC-DAE Indore.

Keywords: CIGSe, DIBS, GMZO, solar cells, UPS

Procedia PDF Downloads 246
216 Facile Route for the Synthesis of NiO/ZnO Nanocomposite Used in Gas Sensors

Authors: Roussin Lontio Fomekong, John Lambi Ngolui, Arnaud Dercorte

Abstract:

Current years have seen increased interest in the synthesis of p/n metal oxide-based nano composites and their great potential in advanced applications, such as opto electronics, photo catalysis and gas sensors. The superior functional performances of the system combining p-type and n-types semiconducting oxyde in comparison to the corresponding single-phase metal oxides are mainly ascribed to the build-up of an inner electric field at the p/n junction interface.

Keywords: nanocomposite, semiconductors, p-n, heterojunction

Procedia PDF Downloads 500
215 Analysis of Grid Connected High Concentrated Photovoltaic Systems for Peak Load Shaving in Kuwait

Authors: Adel A. Ghoneim

Abstract:

Air conditioning devices are substantially utilized in the summer months, as a result maximum loads in Kuwait take place in these intervals. Peak energy consumption are usually more expensive to satisfy compared to other standard power sources. The primary objective of the current work is to enhance the performance of high concentrated photovoltaic (HCPV) systems in an attempt to minimize peak power usage in Kuwait using HCPV modules. High concentrated PV multi-junction solar cells provide a promising method towards accomplishing lowest pricing per kilowatt-hour. Nevertheless, these cells have various features that should be resolved to be feasible for extensive power production. A single diode equivalent circuit model is formulated to analyze multi-junction solar cells efficiency in Kuwait weather circumstances taking into account the effects of both the temperature and the concentration ratio. The diode shunt resistance that is commonly ignored in the established models is considered in the present numerical model. The current model results are successfully validated versus measurements from published data to within 1.8% accuracy. Present calculations reveal that the single diode model considering the shunt resistance provides accurate and dependable results. The electrical efficiency (η) is observed to increase with concentration to a specific concentration level after which it reduces. Implementing grid systems is noticed to increase with concentration to a certain concentration degree after which it decreases. Employing grid connected HCPV systems results in significant peak load reduction.

Keywords: grid connected, high concentrated photovoltaic systems, peak load, solar cells

Procedia PDF Downloads 132
214 The Impact of Total Parenteral Nutrition on Pediatric Stem Cell Transplantation and Its Complications

Authors: R. Alramyan, S. Alsalamah, R. Alrashed, R. Alakel, F. Altheyeb, M. Alessa

Abstract:

Background: Nutritional support with total parenteral nutrition (TPN) is usually commenced with hematopoietic stem cell transplantation (HSCT) patients. However, it has its benefits and risks. Complications related to central venous catheter such as infections, and metabolic disturbances, including abnormal liver function, is usually of concern in such patients. Methods: A retrospective charts review of all pediatric patients who underwent HSCT between the period 2015-2018 in a tertiary hospital in Riyadh, Saudi Arabia. Patients' demographics, types of conditioning, type of nutrition, and patients' outcomes were collected. Statistical analysis was conducted using SPSS version 22. Frequencies and percentages were used to describe categorical variables. Mean, and standard deviation were used for continuous variables. A P value of less than 0.05 was considered as statically significant. Results: a total of 162 HSCTs were identified during the period mentioned. Indication of allogenic transplant included hemoglobinopathy in 50 patients (31%), acute lymphoblastic leukemia in 21 patients (13%). TPN was used in 96 patients (59.30%) for a median of 14 days, nasogastric tube feeding (NGT) in 16 (9.90%) patients for a median of 11 days, and 71 of patients (43.80%) were able to tolerate oral feeding. Out of the 96 patients (59.30%) who were dependent on TPN, 64 patients (66.7%) had severe mucositis in comparison to 17 patients (25.8%) who were either on NGT or tolerated oral intake. (P-value= 0.00). Sinusoidal obstruction syndrome (SOS) was seen in 14 patients (14.6%) who were receiving TPN compared to none in non-TPN patients (P=value 0.001). Moreover, majority of patients who had SOS received myeloablative conditioning therapy for non-malignant disease (hemoglobinopathy). However, there were no statistically significant differences in Graft-vs-Host Disease (both acute and chronic), bacteremia, and patient outcome between both groups. Conclusions: Nutritional support using TPN is used in majority of patients, especially post-myeloablative conditioning associated with severe mucositis. TPN was associated with VOD, especially in hemoglobinopathy patients who received myeloablative therapy. This may emphasize on use of preventative measures such as fluid restriction, use of diuretics, or defibrotide in high-risk patients.

Keywords: hematopoeitic stem cell transplant, HSCT, stem cell transplant, sinusoidal obstruction syndrome, total parenteral nutrition

Procedia PDF Downloads 127
213 Kidney Stones in Individuals Living with Diabetes Mellitus at King Abdul-Aziz Medical City - Tertiary Care Center, Jeddah, Saudi Arabia: A Retrospective Cohort Study

Authors: Suhaib Radi, Ibrahim Basem Nafadi, Abdullah Ahmed Alsulami, Nawaf Faisal Halabi, Abdulrhman Abdullah Alsubhi, Sami Wesam Maghrabi, Waleed Saad Alshehri

Abstract:

Background: Kidney stones greatly affect individuals. The range of these effects regarding multiple kidney stone factors (size, presence of obstruction, and modality of treatment) in stone formers with and without diabetes has not been well explored in the literature to the best of the author's knowledge. Our goal is to investigate this unexplored correlation between diabetes and kidney stones by conducting a Cohort retrospective study to precisely evaluate the effects of this condition and the existence of complications in adult individuals with diabetes in Saudi Arabia in comparison to a non-diabetic control group. Methodology: This is a retrospective cohort study aiming to evaluate the range of effects of kidney stones in stone formers in a group of adults diagnosed with type 2 diabetes mellitus and adults without diabetes between 2017 and 2019 in Jeddah, Saudi Arabia. An IRB approval has been granted for this study. The data was analyzed using SPSS. The data was collected from the 1st of December 2022 until the 1st of March 2023. Results: A total of 254 individuals diagnosed with kidney stones were included, 127 of whom were adult individuals with type 2 diabetes, and 127 were non-diabetics. Our study shows that the individuals affected with diabetes were more likely to have larger kidney stones in comparison to individuals without diabetes (13.12 mm vs. 10.53 mm, p-value = 0.03). Moreover, individuals with hypertension and dyslipidemia also had significantly larger stones. On the other hand, no significant difference was found in the presence of obstruction and modality of treatment between the two groups. Conclusion: This study done in Saudi Arabia found that individuals with kidney stones who concurrently had diabetes formed larger kidney stones, and they were also found to have other comorbidities such as HTN, dyslipidemia, obesity, and renal disease. The significance of these findings could assist in the future of primary and secondary prevention of renal stones.

Keywords: kidney stone, type 2 DM, metabolic syndrome, lithotripsy

Procedia PDF Downloads 70
212 Liquid-Liquid Plug Flow Characteristics in Microchannel with T-Junction

Authors: Anna Yagodnitsyna, Alexander Kovalev, Artur Bilsky

Abstract:

The efficiency of certain technological processes in two-phase microfluidics such as emulsion production, nanomaterial synthesis, nitration, extraction processes etc. depends on two-phase flow regimes in microchannels. For practical application in chemistry and biochemistry it is very important to predict the expected flow pattern for a large variety of fluids and channel geometries. In the case of immiscible liquids, the plug flow is a typical and optimal regime for chemical reactions and needs to be predicted by empirical data or correlations. In this work flow patterns of immiscible liquid-liquid flow in a rectangular microchannel with T-junction are investigated. Three liquid-liquid flow systems are considered, viz. kerosene – water, paraffin oil – water and castor oil – paraffin oil. Different flow patterns such as parallel flow, slug flow, plug flow, dispersed (droplet) flow, and rivulet flow are observed for different velocity ratios. New flow pattern of the parallel flow with steady wavy interface (serpentine flow) has been found. It is shown that flow pattern maps based on Weber numbers for different liquid-liquid systems do not match well. Weber number multiplied by Ohnesorge number is proposed as a parameter to generalize flow maps. Flow maps based on this parameter are superposed well for all liquid-liquid systems of this work and other experiments. Plug length and velocity are measured for the plug flow regime. When dispersed liquid wets channel walls plug length cannot be predicted by known empirical correlations. By means of particle tracking velocimetry technique instantaneous velocity fields in a plug flow regime were measured. Flow circulation inside plug was calculated using velocity data that can be useful for mass flux prediction in chemical reactions.

Keywords: flow patterns, hydrodynamics, liquid-liquid flow, microchannel

Procedia PDF Downloads 361
211 A Numerical Hybrid Finite Element Model for Lattice Structures Using 3D/Beam Elements

Authors: Ahmadali Tahmasebimoradi, Chetra Mang, Xavier Lorang

Abstract:

Thanks to the additive manufacturing process, lattice structures are replacing the traditional structures in aeronautical and automobile industries. In order to evaluate the mechanical response of the lattice structures, one has to resort to numerical techniques. Ansys is a globally well-known and trusted commercial software that allows us to model the lattice structures and analyze their mechanical responses using either solid or beam elements. In this software, a script may be used to systematically generate the lattice structures for any size. On the one hand, solid elements allow us to correctly model the contact between the substrates (the supports of the lattice structure) and the lattice structure, the local plasticity, and the junctions of the microbeams. However, their computational cost increases rapidly with the size of the lattice structure. On the other hand, although beam elements reduce the computational cost drastically, it doesn’t correctly model the contact between the lattice structures and the substrates nor the junctions of the microbeams. Also, the notion of local plasticity is not valid anymore. Moreover, the deformed shape of the lattice structure doesn’t correspond to the deformed shape of the lattice structure using 3D solid elements. In this work, motivated by the pros and cons of the 3D and beam models, a numerically hybrid model is presented for the lattice structures to reduce the computational cost of the simulations while avoiding the aforementioned drawbacks of the beam elements. This approach consists of the utilization of solid elements for the junctions and beam elements for the microbeams connecting the corresponding junctions to each other. When the global response of the structure is linear, the results from the hybrid models are in good agreement with the ones from the 3D models for body-centered cubic with z-struts (BCCZ) and body-centered cubic without z-struts (BCC) lattice structures. However, the hybrid models have difficulty to converge when the effect of large deformation and local plasticity are considerable in the BCCZ structures. Furthermore, the effect of the junction’s size of the hybrid models on the results is investigated. For BCCZ lattice structures, the results are not affected by the junction’s size. This is also valid for BCC lattice structures as long as the ratio of the junction’s size to the diameter of the microbeams is greater than 2. The hybrid model can take into account the geometric defects. As a demonstration, the point clouds of two lattice structures are parametrized in a platform called LATANA (LATtice ANAlysis) developed by IRT-SystemX. In this process, for each microbeam of the lattice structures, an ellipse is fitted to capture the effect of shape variation and roughness. Each ellipse is represented by three parameters; semi-major axis, semi-minor axis, and angle of rotation. Having the parameters of the ellipses, the lattice structures are constructed in Spaceclaim (ANSYS) using the geometrical hybrid approach. The results show a negligible discrepancy between the hybrid and 3D models, while the computational cost of the hybrid model is lower than the computational cost of the 3D model.

Keywords: additive manufacturing, Ansys, geometric defects, hybrid finite element model, lattice structure

Procedia PDF Downloads 87
210 A 30 Year Audit of the Vascular Complications of Ports: Permanent Intravascular Access Devices

Authors: S. Kershaw, P. J. Barry, K. Webb

Abstract:

Background: Cystic Fibrosis (CF) is a chronic lung disease where patients have chronic lung infection punctuated by acute exacerbations that require intermittent intravenous (IV) antibiotics during their lives. With time, peripheral venous access can become difficult and limited. Accessing these veins can become arduous, traumatic, painful and unworkable. A permanent intravascular access device or Port is a small device that is inserted into the central venous system that allows the delivery of medicine eliminating the need for peripheral venous access. Ports represent a convenient and efficient method when venous access is required on a permanent basis however they are also associated with significant vascular complications. Superior Vena Cava Obstruction (SVCO) is a rare but significant vascular complication of ports in this setting. Objective: We aimed to look at a single CF centre’s experience of port-related SVCO over a thirty year period. Methods: Retrospective data was extracted using patient’s notes, electronic radiological reports and local databases over a period in excess of 30 years from 1982 to 2014. Results: 13 patients were identified with SVCO as a result of their port. 11 patients had CF (9 female, 2 male), one male patient had Primary Ciliary Dyskinesia and one female patient had severe Asthma. The mean port function was 1532 days (range 110 – 4049) and the mean age at SVCO was 24 years (range 11.1 to 36.5 years). The most common symptoms were facial oedema (n=8, 61.5%) and dilated veins (n=6, 46.2%). 7 patients had their Ports removed after SVCO. 6 patients underwent attempted stenting (46.2%) and 6 did not. 4 out of the 6 who underwent stenting required/had re-intervention. 3 of the 6 patients who underwent stenting had symptom resolution, however, 4 of the 6 patients who were not stented had symptom resolution also. Symptom resolution was not guaranteed with stenting and required re-intervention in two-thirds. Conclusion: This case series represents the experience of one of the longest established CF units in the UK and represents the largest cohort ever reported in the literature.

Keywords: ports, Superior Vena Cava Obstruction, cystic fibrosis, access devices

Procedia PDF Downloads 295
209 Two-Dimensional Material-Based Negative Differential Resistance Device with High Peak-to- Valley Current Ratio for Multi-Valued Logic Circuits

Authors: Kwan-Ho Kim, Jin-Hong Park

Abstract:

The multi-valued logic (MVL) circuits, which can handle more than two logic states, are one of the promising solutions to overcome the bit density limitations of conventional binary logic systems. Recently, tunneling devices such as Esaki diode and resonant tunneling diode (RTD) have been extensively explored to construct the MVL circuits. These tunneling devices present a negative differential resistance (NDR) phenomenon in which a current decreases as a voltage increases in a specific applied voltage region. Due to this non-monotonic current behavior, the tunneling devices have more than two threshold voltages, consequently enabling construction of MVL circuits. Recently, the emergence of two dimensional (2D) van der Waals (vdW) crystals has opened up the possibility to fabricate such tunneling devices easily. Owing to the defect-free surface of the 2D crystals, a very abrupt junction interface could be formed through a simple stacking process, which subsequently allowed the implementation of a high-performance tunneling device. Here, we report a vdW heterostructure based tunneling device with multiple threshold voltages, which was fabricated with black phosphorus (BP) and hafnium diselenide (HfSe₂). First, we exfoliated BP on the SiO₂ substrate and then transferred HfSe₂ on BP using dry transfer method. The BP and HfSe₂ form type-Ⅲ heterojunction so that the highly doped n+/p+ interface can be easily implemented without additional electrical or chemical doping process. Owing to high natural doping at the junction, record high peak to valley ratio (PVCR) of 16 was observed to the best our knowledge in 2D materials based NDR device. Furthermore, based on this, we first demonstrate the feasibility of the ternary latch by connecting two multi-threshold voltage devices in series.

Keywords: two dimensional van der Waals crystal, multi-valued logic, negative differential resistnace, tunneling device

Procedia PDF Downloads 184
208 A 10 Year Review of the Complications of Ingested and Aspirated Dentures

Authors: Rory Brown, Jessica Daniels, Babatunde Oremule, William Tsang, Sadie Khwaja

Abstract:

Introduction: Dentures are common and are an intervention for both physical and psychological symptoms associated with tooth loss. However, the humble denture can cause morbidity and mortality if swallowed or aspirated. Numerous case reports document complications including hollow viscus perforation, fistula formation and airway compromise. The purpose of this review was to examine the literature documenting cases of swallowed or aspirated dentures over the past ten years to investigate factors that contribute to developing complications. Methods: A Medline literature search was performed to identify cases of denture ingestion or aspiration for over ten years. Data was collected to include patient, appliance and temporal factors that may contribute to developing complications including hollow viscus perforation, fistula formation, abscess, bowel obstruction, necrosis, hemorrhage and airway obstruction. The data was analyzed using observational and inferential statistics in the form of Chi-Squared and Pearson correlation tests. Results: Eighty-five cases of ingested or aspirated dentures were identified from 77 articles published between 1/10/2009 and 31/10/2019. Fourteen articles were excluded because they did not provide sufficient information on individual cases. Complications were documented in 37.6% of patients, and 2 cases resulted in death. There was no significant difference in complication risk based on patient age, hooked appliance, level of impaction, or radiolucency. However, symptoms of greater than 1-day duration are associated with an increased risk of complication (p=0.005). Increased time from ingestion or aspiration to removal is associated with an increased risk of complications, and the p-value remains significant up to and including day 4 (p=0.017). Conclusions: With denture use predicted to rise complications from the denture, ingestion and aspiration may become more frequent. We have demonstrated that increased symptom duration significantly increases the risk of developing complications. Additionally, we established the risk of developing complications is significantly reduced if the denture is removed with four days of aspiration or ingestion. By actively intervening early when presented with a case of swallowed or aspirated dentures, we may be able to reduce the morbidity associated with this unassuming device.

Keywords: aspiration, denture, ingestion, endoscopic foreign, body removal, foreign body impaction

Procedia PDF Downloads 104
207 Mott Transition in the VO2/LSCO Heterojunction

Authors: Yi Hu, Chun-Chi Lin, Shau-En Yeh, Shin Lee

Abstract:

In this study, p–n heterojunctions with La0.5Sr0.5CoO3 (LSCO) and W-doped VO2 thin films were fabricated by the radio frequency (r.f.) magnetron sputtering technique and sol-gel process, respectively. The thickness of VO2 and LSCO thin films are about 40 nm and 400 nm, respectively. Good crystalline match between LSCO and VO2 films was observed from the SEM. The built-in voltages for the junction are about 1.1 V and 2.3 V for the sample in the metallic and insulating state, respectively. The sample can undergo the current induced MIT during applying field when the sample was heated at 40 and 50ºC. This is in agreement with the value obtained from the difference in the work functions of LSCO and VO2. The band structure of the heterojunction was proposed based on the results of analysis.

Keywords: hetrojection, Mott transition, switching , VO2

Procedia PDF Downloads 551
206 Tracheal Stenting to Relieve Respiratory Distress in Patient with Advanced Esophageal Malignancy and Its Anaesthetic Management

Authors: Aarti Agarwal, Ajmal Khan

Abstract:

Background and Objective: Breathing difficulty is most distressing symptom for the patient and their caregivers providing palliative care to individuals with advanced malignancy. It needs to be tackled effectively and sometimes preemptively to provide relief from respiratory obstruction. Interventional procedures like tracheal stenting are becoming increasingly popular as a part of palliation for respiratory symptoms. We present a case of esophageal tumor earlier stented by Gastroenterologist to maintain esophageal patency, but the tumor outgrew to produce tracheal infiltration and thereby causing airway obstruction. Method and Result: 62-year-old man presented with unresectable Carcinoma oesophagus with inability to swallow. A metallic stent was placed by the gastroenterologist, to maintain esophageal patency and enable patient to swallow. Two months later, the patient returned to hospital in emergency with respiratory distress. CT neck and thorax revealed tumor infiltration through posterior tracheal wall. Lower extent of the tumor was till 1 cm above the carina. Airway stenting with Tracheo bronchial stent with Y configuration was planned under general anaesthesia with airway blocks. Superior Laryngeal Nerve Block, Glossopharyngeal block and Trans tracheal infiltration of local anaesthetics were performed. The patient was sedated with Fentanyl, Midazolam and propofol infusion but was breathing spontaneously. Once the rigid bronchoscope was placed inside trachea, breathing was supported with oxygen and sevoflurane. Initially, the trachea was cleared of tumor by coring. After creating space, tracheal stent was positioned and deployed. After stent placement patient was awakened, suctioned and nebulized. His respiratory stridor relieved instantaneously and was shifted to recovery. Conclusion: Airway blocks help in decreasing the incidence and severity of coughing during airway instrumentation thereby help in proper stent placement. They also reduce the requirement of general anaesthetics and hasten the post stenting recovery. Airway stent provided immediate relief to patient from symptoms of respiratory difficulty. Decision for early tracheal stenting may be taken for a select group of patients with high propensity for local spread, thereby avoiding respiratory complications and providing better quality of life in patients with inoperable malignancy.

Keywords: tracheal stent, respiratory difficulty, esophageal tumor, anaesthetic management

Procedia PDF Downloads 196
205 Acute Peritonitis Caused by Perforated Appendicitis Accompanied by Synchronous Encephalopathy: A Rare Primary Presentation of Varicella Zoster Infection

Authors: Shahla Afshar Paiman, Sedigheh Madani, Zahra Hosseininezhad

Abstract:

Introduction: The most common causes of appendix luminal obstruction are fecaliths and lymphoid follicle hyperplasia. Appendicitis is a very rare Gastrointestinal complication of varicella zosterand it is mostly observed in immune-compromised patient. Case presentation: Here we reported a case of varicella zoster-related perforated appendicitis with synchronous encephalopathy as a first presentation of chickenpox in a 10-year-old boy. He had no history of immunodeficiency or predisposing factors and his diagnosis is confirmed by both serological lab tests and abdominal fluid (peritoneal secretion) PCR. Conclusion: Varicella zoster could cause appendicitis as first presentation, along with other critical complications look likes encephalopathy.

Keywords: Varicella zoster, appendicitis, encephalitis, children

Procedia PDF Downloads 28
204 Molecular Pathogenesis of NASH through the Dysregulation of Metabolic Organ Network in the NASH-HCC Model Mouse Treated with Streptozotocin-High Fat Diet

Authors: Bui Phuong Linh, Yuki Sakakibara, Ryuto Tanaka, Elizabeth H. Pigney, Taishi Hashiguchi

Abstract:

NASH is an increasingly prevalent chronic liver disease that can progress to hepatocellular carcinoma and now is attracting interest worldwide. The STAM™ model is a clinically-correlated murine NASH model which shows the same pathological progression as NASH patients and has been widely used for pharmacological and basic research. The multiple parallel hits hypothesis suggests abnormalities in adipocytokines, intestinal microflora, and endotoxins are intertwined and could contribute to the development of NASH. In fact, NASH patients often exhibit gut dysbiosis and dysfunction in adipose tissue and metabolism. However, the analysis of the STAM™ model has only focused on the liver. To clarify whether the STAM™ model can also mimic multiple pathways of NASH progression, we analyzed the organ crosstalk interactions between the liver and the gut and the phenotype of adipose tissue in the STAM™ model. NASH was induced in male mice by a single subcutaneous injection of 200 µg streptozotocin 2 days after birth and feeding with high-fat diet after 4 weeks of age. The mice were sacrificed at NASH stage. Colon samples were snap-frozen in liquid nitrogen and stored at -80˚C for tight junction-related protein analysis. Adipose tissue was prepared into paraffin blocks for HE staining. Blood adiponectin was analyzed to confirm changes in the adipocytokine profile. Tight junction-related proteins in the intestine showed that expression of ZO-1 decreased with the progression of the disease. Increased expression of endotoxin in the blood and decreased expression of Adiponectin were also observed. HE staining revealed hypertrophy of adipocytes. Decreased expression of ZO-1 in the intestine of STAM™ mice suggests the occurrence of leaky gut, and abnormalities in adipocytokine secretion were also observed. Together with the liver, phenotypes in these organs are highly similar to human NASH patients and might be involved in the pathogenesis of NASH.

Keywords: Non-alcoholic steatohepatitis, hepatocellular carcinoma, fibrosis, organ crosstalk, leaky gut

Procedia PDF Downloads 132
203 Uterine Leiomyomas and Urological Complications

Authors: Dharshini Selvarajah, Nicula Lui, Karen Kong

Abstract:

Background: Uterine fibroids are a common benign gynaecologic neoplasm in reproductive-aged women. Fibroids may become symptomatic in a vast majority of nulliparous women. Their diagnosis and management is often coordinated between gyneacologists, radiologists and urologists depending on the anatomical location, growth, size and the fibroids sarcomatous evolvement. Some patients may develop obstructive uropathy symptoms, either uni or bilateral secondary urethral obstruction causing hydronephrosis. Uterine artery emoblisation (UAE) has previously shown to effectively resolve symptoms as well as relieve urethral obstruction and resolve the hydronephrosis. UAE has now established itself as an organ preserving and minimally invasive procedure in the management of symptomatic uterine fibroids. It is a safe and effective alternative to hysterectomy for resolving fibroid related pressure symptoms. The case presented examines the clinical manifestations and impact of uterine fibroids on the urinary tract system. The therapeutic options to relieve the urological symptoms as well as preserve fertility are explored and presented. Case: The case is a 29-year-old Nepalese female admitted to hospital with recurrent urosepsis with multiresistant organisms. This was on a background of an enlarged uterus (measuring 17cm x11cm) with multiple subserosal, intramural and exophytic fibroids- causing external ureteric compression. She had bilateral ureteric stents insitu and required bilateral right and left nephrostomies during repeated episodes of urosepsis and bilateral ureteric obstruction. The left nephrostomy was removed a month prior to admission and her most recent CT KUB demonstrated hypofunctioning ureteric stents with bilateral hydronephrosis. Options of hysterectomy versus uterine artery emoblisation (UAE) were extensively explored. The patient was keen to preserve fertility. Risks associated with UAE such as expulsion of the submucosal component of the fibroids and the possibilities of sepsis in the setting of ongoing ureteric colonisation were particularly high. The patient opted to trial UAE even though the risks of recurrent hospital admissions with urosepsis were going to be particularly high. In the event, the uterus fails to shrink adequately enough to relieve the obstructed ureters a hysterectomy would inevitably be required in future. Day 3 post UAE the patient developed fevers, was hypotensive and tachycardic post-receiving prophylactic meropenem and fluconazole pre emoblisation. She was noted to have a CRP of 293 with the most recent urine culture during this time growing Candida albicans. The patient was recommenced on oral fluconazole and IV meropenem, with good effect. Her repeat renal tract ultrasound post-UAE showed ongoing marked left hydronephrosis relatively unchanged from the scan one month prior to the procedure, however the right-sided hydronephrosis had resolved. The patient was discharged on a 2-week course of antibiotics. The patient will have a repeat renal tract ultrasound and MRI of the ureters to re-evaluate the degree of hydronephrosis and progress- this was unavailable at the time of abstract submission and will be presented at the conference. Conclusion: Fibroids are a common benign tumour of the uterus and can frequently impact the lower urinary system resulting in significant uropathy. They often enlarge and compress the urinary bladder, urethra and lower end of the ureters. The effectiveness of UAE as a fertility preserving option is described.

Keywords: Uterine leiomyomas and urological complications, uterine artery embolisation for fibroids, Uterine fibroids and complications, Management of uterine fibroids

Procedia PDF Downloads 193
202 Solar Panel Design Aspects and Challenges for a Lunar Mission

Authors: Mannika Garg, N. Srinivas Murthy, Sunish Nair

Abstract:

TeamIndus is only Indian team participated in the Google Lunar X Prize (GLXP). GLXP is an incentive prize space competition which is organized by the XPrize Foundation and sponsored by Google. The main objective of the mission is to soft land a rover on the moon surface, travel minimum displacement of 500 meters and transmit HD and NRT videos and images to the Earth. Team Indus is designing a Lunar Lander which carries Rover with it and deliver onto the surface of the moon with a soft landing. For lander to survive throughout the mission, energy is required to operate all attitude control sensors, actuators, heaters and other necessary components. Photovoltaic solar array systems are the most common and primary source of power generation for any spacecraft. The scope of this paper is to provide a system-level approach for designing the solar array systems of the lander to generate required power to accomplish the mission. For this mission, the direction of design effort is to higher efficiency, high reliability and high specific power. Towards this approach, highly efficient multi-junction cells have been considered. The design is influenced by other constraints also like; mission profile, chosen spacecraft attitude, overall lander configuration, cost effectiveness and sizing requirements. This paper also addresses the various solar array design challenges such as operating temperature, shadowing, radiation environment and mission life and strategy of supporting required power levels (peak and average). The challenge to generate sufficient power at the time of surface touchdown, due to low sun elevation (El) and azimuth (Az) angle which depends on Lunar landing site, has also been showcased in this paper. To achieve this goal, energy balance analysis has been carried out to study the impact of the above-mentioned factors and to meet the requirements and has been discussed in this paper.

Keywords: energy balance analysis, multi junction solar cells, photovoltaic, reliability, spacecraft attitude

Procedia PDF Downloads 204
201 Management of Urological Complications Secondary to Uterine Fibroids

Authors: Dharshini Selvarajah, Karen Kong

Abstract:

Background: Uterine fibroids are a common benign gynaecologic neoplasm in reproductive-aged women. Fibroids may become symptomatic in a vast majority of nulliparous women. Their diagnosis and management are often coordinated between gyneacologists, radiologists and urologists depending on the anatomical location, growth, size and the fibroids' sarcomatous evolvement. Some patients may develop obstructive uropathy symptoms, either uni or bilateral secondary urethral obstruction causing hydronephrosis. Uterine artery embolization (UAE) has previously been shown to effectively resolve symptoms as well as relieve urethral obstruction and resolve hydronephrosis. UAE has now established itself as an organ-preserving and minimally invasive procedure in the management of symptomatic uterine fibroids. It is a safe and effective alternative to hysterectomy for resolving fibroid-related pressure symptoms. The case presented examines the clinical manifestations and impact of uterine fibroids on the urinary tract system. The therapeutic options to relieve the urological symptoms as well as preserve fertility are explored and presented. Case: The case is a 29-year-old Nepalese female admitted to the hospital with recurrent urosepsis with multiresistant organisms. This was on a background of an enlarged uterus (measuring 17cm x11cm) with multiple subserosal, intramural and exophytic fibroids- causing external ureteric compression. She had bilateral ureteric stents in situ and required bilateral right and left nephrostomies during repeated episodes of urosepsis and bilateral ureteric obstruction. The left nephrostomy was removed a month prior to admission, and her most recent CT KUB demonstrated hypofunctioning ureteric stents with bilateral hydronephrosis. Options of hysterectomy versus uterine artery embolization (UAE) were extensively explored. The patient was keen to preserve fertility. Risks associated with UAE, such as the expulsion of the submucosal component of the fibroids and the possibilities of sepsis in the setting of ongoing ureteric colonisation were particularly high. The patient opted to trial UAE even though the risks of recurrent hospital admissions with urosepsis were going to be particularly high. In the event, the uterus fails to shrink adequately enough to relieve the obstructed ureters, a hysterectomy would inevitably be required in the future. Day 3 post-UAE the patient developed fevers, was hypotensive and tachycardic post-receiving prophylactic meropenem and fluconazole pre emoblisation. She was noted to have a CRP of 293 with the most recent urine culture during this time growing Candida albicans. The patient was recommenced on oral fluconazole and IV meropenum, with good effect. Her repeat renal tract ultrasound post-UAE showed ongoing marked left hydronephrosis relatively unchanged from the scan one month prior to the procedure; however, the right-sided hydronephrosis had resolved. The patient was discharged on a 2-week course of antibiotics. The patient will have a repeat renal tract ultrasound and MRI of the ureters to re-evaluate the degree of hydronephrosis and progress- this was unavailable at the time of abstract submission and will be presented at the conference. Conclusion: Fibroids are a common benign tumor of the uterus and can frequently impact the lower urinary system resulting in significant uropathy. They often enlarge and compress the urinary bladder, urethra and lower end of the ureters. The effectiveness of the UAE as a fertility-preserving option is described.

Keywords: uterine artery embolisation for fibroids, urological complications from fibroids, uropathy of fibroids, obstructive fibroid management

Procedia PDF Downloads 182
200 Hot Carrier Photocurrent as a Candidate for an Intrinsic Loss in a Single Junction Solar Cell

Authors: Jonas Gradauskas, Oleksandr Masalskyi, Ihor Zharchenko

Abstract:

The advancement in improving the efficiency of conventional solar cells toward the Shockley-Queisser limit seems to be slowing down or reaching a point of saturation. The challenges hindering the reduction of this efficiency gap can be categorized into extrinsic and intrinsic losses, with the former being theoretically avoidable. Among the five intrinsic losses, two — the below-Eg loss (resulting from non-absorption of photons with energy below the semiconductor bandgap) and thermalization loss —contribute to approximately 55% of the overall lost fraction of solar radiation at energy bandgap values corresponding to silicon and gallium arsenide. Efforts to minimize the disparity between theoretically predicted and experimentally achieved efficiencies in solar cells necessitate the integration of innovative physical concepts. Hot carriers (HC) present a contemporary approach to addressing this challenge. The significance of hot carriers in photovoltaics is not fully understood. Although their excessive energy is thought to indirectly impact a cell's performance through thermalization loss — where the excess energy heats the lattice, leading to efficiency loss — evidence suggests the presence of hot carriers in solar cells. Despite their exceptionally brief lifespan, tangible benefits arise from their existence. The study highlights direct experimental evidence of hot carrier effect induced by both below- and above-bandgap radiation in a singlejunction solar cell. Photocurrent flowing across silicon and GaAs p-n junctions is analyzed. The photoresponse consists, on the whole, of three components caused by electron-hole pair generation, hot carriers, and lattice heating. The last two components counteract the conventional electron-hole generation-caused current required for successful solar cell operation. Also, a model of the temperature coefficient of the voltage change of the current–voltage characteristic is used to obtain the hot carrier temperature. The distribution of cold and hot carriers is analyzed with regard to the potential barrier height of the p-n junction. These discoveries contribute to a better understanding of hot carrier phenomena in photovoltaic devices and are likely to prompt a reevaluation of intrinsic losses in solar cells.

Keywords: solar cell, hot carriers, intrinsic losses, efficiency, photocurrent

Procedia PDF Downloads 29
199 Magnetoelastically Induced Perpendicular Magnetic Anisotropy and Perpendicular Exchange Bias of CoO/CoPt Multilayer Films

Authors: Guo Lei, Wang Yue, Nakamura Yoshio, Shi Ji

Abstract:

Recently, perpendicular exchange bias (PEB) is introduced as an active topic attracting continuous efforts. Since its discovery, extrinsic control of PEB has been proposed, due to its scientific significance in spintronic devices and potential application in high density magnetic random access memory with perpendicular magnetic tunneling junction (p-MTJ). To our knowledge, the researches aiming to controlling PEB so far are focused mainly on enhancing the interfacial exchange coupling by adjusting the FM/AFM interface roughness, or optimizing the crystalline structures of FM or AFM layer by employing different seed layers. In present work, the effects of magnetoelastically induced PMA on PEB have been explored in [CoO5nm/CoPt5nm]5 multilayer films. We find the PMA strength of FM layer also plays an important role on PEB at the FM/AFM interface and it is effective to control PEB of [CoO5nm/CoPt5nm]5 multilayer films by changing the magnetoelastically induced PMA of CoPt layer. [CoO5nm/CoPt5nm]5 multilayer films were deposited by magnetron sputtering on fused quartz substrate at room temperature, then annealed at 100°C, 250°C, 300°C and 375°C for 3h, respectively. XRD results reveal that all the samples are well crystallized with preferred fcc CoPt (111) orientation. The continuous multilayer structure with sharp component transition at the CoO5nm/CoPt5nm interface are identified clearly by transmission electron microscopy (TEM), x-ray reflectivity (XRR) and atomic force microscope (AFM). CoPt layer in-plane tensile stress is calculated by sin2φ method, and we find it increases gradually upon annealing from 0.99 GPa (as-deposited) up to 3.02 GPa (300oC-annealed). As to the magnetic property, significant enhancement of PMA is achieved in [CoO5nm/CoPt5nm]5 multilayer films after annealing due to the increase of CoPt layer in-plane tensile stress. With the enhancement of magnetoelastically induced PMA, great improvement of PEB is also achieved in [CoO5nm/CoPt5nm]5 multilayer films, which increases from 130 Oe (as-deposited) up to 1060 Oe (300oC-annealed), showing the same change tendency as PMA and the strong correlation with CoPt layer in-plane tensile stress. We consider it is the increase of CoPt layer in-plane tensile stress that leads to the enhancement of PMA, and thus the enhancement of magnetoelastically induced PMA results in the improvement of PEB in [CoO5nm/CoPt5nm]5 multilayer films.

Keywords: perpendicular exchange bias, magnetoelastically induced perpendicular magnetic anisotropy, CoO5nm/CoPt5nm]5 multilayer film with in-plane stress, perpendicular magnetic tunneling junction

Procedia PDF Downloads 433
198 A Structural Equation Model of Risk Perception of Rockfall for Revisit Intention

Authors: Ya-Fen Lee, Yun-Yao Chi

Abstract:

The study aims to explore the relationship between risk perceptions of rockfall and revisit intention using a Structural Equation Modelling (SEM) analysis. A total of 573 valid questionnaires are collected from travelers to Taroko National Park, Taiwan. The findings show the majority of travellers have the medium perception of rockfall risk, and are willing to revisit the Taroko National Park. The revisit intention to Taroko National Park is influenced by hazardous preferences, willingness-to-pay, obstruction and attraction. The risk perception has an indirect effect on revisit intention through influencing willingness-to-pay. The study results can be a reference for mitigation the rockfall disaster.

Keywords: risk perception, rockfall, revisit intention, structural equation modelling

Procedia PDF Downloads 402
197 Mass Transfer Studies of Carbon Dioxide Absorption in Sodium Hydroxide in Millichannels

Authors: A. Durgadevi, S. Pushpavanam

Abstract:

In this work, absorption studies are done by conducting experiments of 99.9 (v/v%) pure CO₂ with various concentrations of sodium hydroxide solutions in a T-junction glass circular milli-channel. The gas gets absorbed in the aqueous phase resulting in the shrinking of slugs. This phenomenon is used to develop a lumped parameter model. Using this model, the chemical dissolution dynamics and the mass transfer characteristics of the CO₂-NaOH system is analysed. The liquid side mass transfer coefficient is determined with the help of the experimental data.

Keywords: absorption, dissolution dynamics, lumped parameter model, milli-channel, mass transfer coefficient

Procedia PDF Downloads 249
196 Density Based Traffic System Using Pic Microcontroller

Authors: Tatipamula Samiksha Goud, .A.Naveena, M.sresta

Abstract:

Traffic congestion is a major issue in many cities throughout the world, particularly in urban areas, and it is past time to switch from a fixed timer mode to an automated system. The current traffic signalling system is a fixed-time system that is inefficient if one lane is more functional than the others. A structure for an intelligent traffic control system is being designed to address this issue. When traffic density is higher on one side of a junction, the signal's green time is extended in comparison to the regular time. This study suggests a technique in which the signal's time duration is assigned based on the amount of traffic present at the time. Infrared sensors can be used to do this.

Keywords: infrared sensors, micro-controllers, LEDs, oscillators

Procedia PDF Downloads 102
195 CRISPR/Cas9 Based Gene Stacking in Plants for Virus Resistance Using Site-Specific Recombinases

Authors: Sabin Aslam, Sultan Habibullah Khan, James G. Thomson, Abhaya M. Dandekar

Abstract:

Losses due to viral diseases are posing a serious threat to crop production. A quick breakdown of resistance to viruses like Cotton Leaf Curl Virus (CLCuV) demands the application of a proficient technology to engineer durable resistance. Gene stacking has recently emerged as a potential approach for integrating multiple genes in crop plants. In the present study, recombinase technology has been used for site-specific gene stacking. A target vector (pG-Rec) was designed for engineering a predetermined specific site in the plant genome whereby genes can be stacked repeatedly. Using Agrobacterium-mediated transformation, the pG-Rec was transformed into Coker-312 along with Nicotiana tabacum L. cv. Xanthi and Nicotiana benthamiana. The transgene analysis of target lines was conducted through junction PCR. The transgene positive target lines were used for further transformations to site-specifically stack two genes of interest using Bxb1 and PhiC31 recombinases. In the first instance, Cas9 driven by multiplex gRNAs (for Rep gene of CLCuV) was site-specifically integrated into the target lines and determined by the junction PCR and real-time PCR. The resulting plants were subsequently used to stack the second gene of interest (AVP3 gene from Arabidopsis for enhancing cotton plant growth). The addition of the genes is simultaneously achieved with the removal of marker genes for recycling with the next round of gene stacking. Consequently, transgenic marker-free plants were produced with two genes stacked at the specific site. These transgenic plants can be potential germplasm to introduce resistance against various strains of cotton leaf curl virus (CLCuV) and abiotic stresses. The results of the research demonstrate gene stacking in crop plants, a technology that can be used to introduce multiple genes sequentially at predefined genomic sites. The current climate change scenario highlights the use of such technologies so that gigantic environmental issues can be tackled by several traits in a single step. After evaluating virus resistance in the resulting plants, the lines can be a primer to initiate stacking of further genes in Cotton for other traits as well as molecular breeding with elite cotton lines.

Keywords: cotton, CRISPR/Cas9, gene stacking, genome editing, recombinases

Procedia PDF Downloads 117
194 Airway Resistance Evaluation by Respiratory İnductive Plethysmography in Subjects with Airway Obstructions

Authors: Aicha Laouani, Sonia Rouatbi, Saad Saguem, Gila Benchetrit, Pascale calabrese

Abstract:

A new approach based on respiratory inductive plethysmography (RIP) signal analysis has been used for bronchoconstriction changes evaluation in 50 healthy controls and in 44 adults with moderate bronchial obstruction treated with a bronchodilatation protocol. Thoracic and abdominal motions were recorded ( 5 min) by RIP. For each recording the thoracoabdominal signals were analysed and a mean distance (D) was calculated. Airway resistance (Raw) and spirometric data were measured with a body plethysmograph. The results showed that both D and Raw were higher in subjects compared to the healthy group. Significant decreases of D and Raw were also observed after bronchodilatation in the obstructive group. There was also a positive and a significant correlation between D and Raw in subjects before and after bronchodilatation. This D calculated from RIP Signals could be used as a non invasive tool for continuous monitoring of bronchoconstriction changes.

Keywords: airway resistance, bronchoconstriction, thorax, respiratory inductive plethysmography

Procedia PDF Downloads 311
193 The Temporal Implications of Spatial Prospects

Authors: Zhuo Job Chen, Kevin Nute

Abstract:

The work reported examines potential linkages between spatial and temporal prospects, and more specifically, between variations in the spatial depth and foreground obstruction of window views, and observers’ sense of connection to the future. It was found that external views from indoor spaces were strongly associated with a sense of the future, that partially obstructing such a view with foreground objects significantly reduced its association with the future, and replacing it with a pictorial representation of the same scene (with no real actual depth) removed most of its temporal association. A lesser change in the spatial depth of the view, however, had no apparent effect on association with the future. While the role of spatial depth has still to be confirmed, the results suggest that spatial prospects directly affect temporal ones. The word “prospect” typifies the overlapping of the spatial and temporal in most human languages. It originated in classical times as a purely spatial term, but in the 16th century took on the additional temporal implication of an imagined view ahead, of the future. The psychological notion of prospection, then, has its distant origins in a spatial analogue. While it is not yet proven that space directly structures our processing of time at a physiological level, it is generally agreed that it commonly does so conceptually. The mental representation of possible futures has been a central part of human survival as a species (Boyer, 2008; Suddendorf & Corballis, 2007). A sense of the future seems critical not only practically, but also psychologically. It has been suggested, for example, that lack of a positive image of the future may be an important contributing cause of depression (Beck, 1974; Seligman, 2016). Most people in the developed world now spend more than 90% of their lives indoors. So any direct link between external views and temporal prospects could have important implications for both human well-being and building design. We found that the ability to see what lies in front of us spatially was strongly associated with a sense of what lies ahead temporally. Partial obstruction of a view was found to significantly reduce that sense connection to the future. Replacing a view with a flat pictorial representation of the same scene removed almost all of its connection with the future, but changing the spatial depth of a real view appeared to have no significant effect. While foreground obstructions were found to reduce subjects’ sense of connection to the future, they increased their sense of refuge and security. Consistent with Prospect and Refuge theory, an ideal environment, then, would seem to be one in which we can “see without being seen” (Lorenz, 1952), specifically one that conceals us frontally from others, without restricting our own view. It is suggested that these optimal conditions might be translated architecturally as screens, the apertures of which are large enough for a building occupant to see through unobstructed from close by, but small enough to conceal them from the view of someone looking from a distance outside.

Keywords: foreground obstructions, prospection, spatial depth, window views

Procedia PDF Downloads 94