Search results for: PET / CT (Positron Emission Tomography / Computed Tomography)
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 2398

Search results for: PET / CT (Positron Emission Tomography / Computed Tomography)

2128 Endoscopic Treatment of Esophageal Injuries Using Vacuum Therapy

Authors: Murad Gasanov, Shagen Danielyan, Ali Gasanov, Yuri Teterin, Peter Yartsev

Abstract:

Background: Despite the advances made in modern surgery, the treatment of patients with esophageal injuries remains one of the most topical and complex issues. In recent years, high-technology minimally invasive methods, such as endoscopic vacuum therapy (EVT) in the treatment of esophageal injuries. The effectiveness of EVT has been sufficiently studied in case of failure of esophageal anastomoses, however the application of this method in case of mechanical esophageal injuries is limited by a small series of observations, indicating the necessity of additional study. Aim: The aim was to аnalyzed of own experience in the use of endoscopic vacuum therapy (EVT) in a comprehensive examination of patients with esophageal injuries. Methods: We analyzed the results of treatment of 24 patients with mechanical injuries of the esophagus for the period 2019-2021. Complex treatment of patients included the use of minimally invasive technologies, including percutaneous endoscopic gastrostomy (PEG), EVT and video-assisted thoracoscopic debridement. Evaluation of the effectiveness of treatment was carried out using multislice computed tomography (MSCT), endoscopy and laboratory tests. The duration of inpatient treatment and the duration of EVT, the number of system replacements, complications and mortality were taken into account. Result: EVT in patients with mechanical injuries of the esophagus allowed to achieve epithelialization of the esophageal defect in 21 patients (87.5%) in the form of linear scar on the site of perforation or pseudodiverticulum. Complications were noted in 4 patients (16.6%), including bleeding (2) and and esophageal stenosis in the perforation area (2). Lethal outcome was in one observation (4.2%). Conclusion. EVT may be the method of choice in complex treatment in patients with esophageal lesions.

Keywords: esophagus injuries, damage to the esophagus, perforation of the esophagus, spontaneous perforation of the esophagus, mediastinitis, endoscopic vacuum therapy

Procedia PDF Downloads 79
2127 Biophysical Features of Glioma-Derived Extracellular Vesicles as Potential Diagnostic Markers

Authors: Abhimanyu Thakur, Youngjin Lee

Abstract:

Glioma is a lethal brain cancer whose early diagnosis and prognosis are limited due to the dearth of a suitable technique for its early detection. Current approaches, including magnetic resonance imaging (MRI), computed tomography (CT), and invasive biopsy for the diagnosis of this lethal disease, hold several limitations, demanding an alternative method. Recently, extracellular vesicles (EVs) have been used in numerous biomarker studies, majorly exosomes and microvesicles (MVs), which are found in most of the cells and biofluids, including blood, cerebrospinal fluid (CSF), and urine. Remarkably, glioma cells (GMs) release a high number of EVs, which are found to cross the blood-brain-barrier (BBB) and impersonate the constituents of parent GMs including protein, and lncRNA; however, biophysical properties of EVs have not been explored yet as a biomarker for glioma. We isolated EVs from cell culture conditioned medium of GMs and regular primary culture, blood, and urine of wild-type (WT)- and glioma mouse models, and characterized by nano tracking analyzer, transmission electron microscopy, immunogold-EM, and differential light scanning. Next, we measured the biophysical parameters of GMs-EVs by using atomic force microscopy. Further, the functional constituents of EVs were examined by FTIR and Raman spectroscopy. Exosomes and MVs-derived from GMs, blood, and urine showed distinction biophysical parameters (roughness, adhesion force, and stiffness) and different from that of regular primary glial cells, WT-blood, and -urine, which can be attributed to the characteristic functional constituents. Therefore, biophysical features can be potential diagnostic biomarkers for glioma.

Keywords: glioma, extracellular vesicles, exosomes, microvesicles, biophysical properties

Procedia PDF Downloads 116
2126 Optimized Electron Diffraction Detection and Data Acquisition in Diffraction Tomography: A Complete Solution by Gatan

Authors: Saleh Gorji, Sahil Gulati, Ana Pakzad

Abstract:

Continuous electron diffraction tomography, also known as microcrystal electron diffraction (MicroED) or three-dimensional electron diffraction (3DED), is a powerful technique, which in combination with cryo-electron microscopy (cryo-ED), can provide atomic-scale 3D information about the crystal structure and composition of different classes of crystalline materials such as proteins, peptides, and small molecules. Unlike the well-established X-ray crystallography method, 3DED does not require large single crystals and can collect accurate electron diffraction data from crystals as small as 50 – 100 nm. This is a critical advantage as growing larger crystals, as required by X-ray crystallography methods, is often very difficult, time-consuming, and expensive. In most cases, specimens studied via 3DED method are electron beam sensitive, which means there is a limitation on the maximum amount of electron dose one can use to collect the required data for a high-resolution structure determination. Therefore, collecting data using a conventional scintillator-based fiber coupled camera brings additional challenges. This is because of the inherent noise introduced during the electron-to-photon conversion in the scintillator and transfer of light via the fibers to the sensor, which results in a poor signal-to-noise ratio and requires a relatively higher and commonly specimen-damaging electron dose rates, especially for protein crystals. As in other cryo-EM techniques, damage to the specimen can be mitigated if a direct detection camera is used which provides a high signal-to-noise ratio at low electron doses. In this work, we have used two classes of such detectors from Gatan, namely the K3® camera (a monolithic active pixel sensor) and Stela™ (that utilizes DECTRIS hybrid-pixel technology), to address this problem. The K3 is an electron counting detector optimized for low-dose applications (like structural biology cryo-EM), and Stela is also a counting electron detector but optimized for diffraction applications with high speed and high dynamic range. Lastly, data collection workflows, including crystal screening, microscope optics setup (for imaging and diffraction), stage height adjustment at each crystal position, and tomogram acquisition, can be one of the other challenges of the 3DED technique. Traditionally this has been all done manually or in a partly automated fashion using open-source software and scripting, requiring long hours on the microscope (extra cost) and extensive user interaction with the system. We have recently introduced Latitude® D in DigitalMicrograph® software, which is compatible with all pre- and post-energy-filter Gatan cameras and enables 3DED data acquisition in an automated and optimized fashion. Higher quality 3DED data enables structure determination with higher confidence, while automated workflows allow these to be completed considerably faster than before. Using multiple examples, this work will demonstrate how to direct detection electron counting cameras enhance 3DED results (3 to better than 1 Angstrom) for protein and small molecule structure determination. We will also show how Latitude D software facilitates collecting such data in an integrated and fully automated user interface.

Keywords: continuous electron diffraction tomography, direct detection, diffraction, Latitude D, Digitalmicrograph, proteins, small molecules

Procedia PDF Downloads 56
2125 X-Ray Detector Technology Optimization In CT Imaging

Authors: Aziz Ikhlef

Abstract:

Most of multi-slices CT scanners are built with detectors composed of scintillator - photodiodes arrays. The photodiodes arrays are mainly based on front-illuminated technology for detectors under 64 slices and on back-illuminated photodiode for systems of 64 slices or more. The designs based on back-illuminated photodiodes were being investigated for CT machines to overcome the challenge of the higher number of runs and connection required in front-illuminated diodes. In backlit diodes, the electronic noise has already been improved because of the reduction of the load capacitance due to the routing reduction. This translated by a better image quality in low signal application, improving low dose imaging in large patient population. With the fast development of multi-detector-rows CT (MDCT) scanners and the increasing number of examinations, the clinical community has raised significant concerns on radiation dose received by the patient in both medical and regulatory community. In order to reduce individual exposure and in response to the recommendations of the International Commission on Radiological Protection (ICRP) which suggests that all exposures should be kept as low as reasonably achievable (ALARA), every manufacturer is trying to implement strategies and solutions to optimize dose efficiency and image quality based on x-ray emission and scanning parameters. The added demands on the CT detector performance also comes from the increased utilization of spectral CT or dual-energy CT in which projection data of two different tube potentials are collected. One of the approaches utilizes a technology called fast-kVp switching in which the tube voltage is switched between 80kVp and 140kVp in fraction of a millisecond. To reduce the cross-contamination of signals, the scintillator based detector temporal response has to be extremely fast to minimize the residual signal from previous samples. In addition, this paper will present an overview of detector technologies and image chain improvement which have been investigated in the last few years to improve the signal-noise ratio and the dose efficiency CT scanners in regular examinations and in energy discrimination techniques. Several parameters of the image chain in general and in the detector technology contribute in the optimization of the final image quality. We will go through the properties of the post-patient collimation to improve the scatter-to-primary ratio, the scintillator material properties such as light output, afterglow, primary speed, crosstalk to improve the spectral imaging, the photodiode design characteristics and the data acquisition system (DAS) to optimize for crosstalk, noise and temporal/spatial resolution.

Keywords: computed tomography, X-ray detector, medical imaging, image quality, artifacts

Procedia PDF Downloads 231
2124 Study of Interaction between Ascorbic Acid and Bovine Hemoglobin by Multispectroscopic Methods

Authors: Krishnamoorthy Shanmugaraj, Malaichamy Ilanchelian

Abstract:

Ascorbic acid is an essential component in the diet of humans, and also is a typical long used pharmaceutical agent. In the present contribution, we have carried out a detailed study on the binding interaction of ascorbic acid (AA) with bovine hemoglobin (BHb) using steady state emission, time resolved fluorescence, UV-Vis absorption, circular dichroism (CD), Fourier transform infra-red (FT-IR) and three dimensional emission (3D) spectral studies. The results from the emission spectral studies unveiled that the quenching of BHb emission by AA is attributed to the formation of a complex in the ground state (static in nature) after correcting for inner filter effect. The binding parameters calculated from corrected emission quenching data revealed that BHb exhibited a significant binding affinity towards AA. Moreover, AA induced tertiary and secondary conformational changes of BHb were monitored by UV-Vis absorption, CD, FT-IR and 3D emission spectral studies. The results presented here will help to further understand the credible mechanism of BHb-AA system which is expected to provide insights into conformational and microenvironmental changes of BHb.

Keywords: ascorbic acid, bovine hemoglobin, circular dichroism, three dimensional emission spectral studies

Procedia PDF Downloads 933
2123 A Clinical Study of Tracheobronchopathia Osteochondroplastica: Findings from a Large Chinese Cohort

Authors: Ying Zhu, Ning Wu, Hai-Dong Huang, Yu-Chao Dong, Qin-Ying Sun, Wei Zhang, Qin Wang, Qiang Li

Abstract:

Background and study aims: Tracheobronchopathia osteochondroplastica (TO) is an uncommon disease of the tracheobronchial system that leads to narrowing of the airway lumen from cartilaginous and/or osseous submucosal nodules. The aim of this study is to perform a detailed review of this rare disease in a large cohort of patients with TO proven by fiberoptic bronchoscopy from China. Patients and Methods: Retrospective chart review was performed on 41,600 patients who underwent bronchoscopy in the Department of Respiratory Medicine of Changhai Hospital between January 2005 and December 2012. Cases of TO were identified based on characteristic features during bronchoscopic examination. Results: 22 cases of bronchoscopic TO were identified. Among whom one-half were male and the mean age was 47.45 ±10.91 years old. The most frequent symptoms at presentation were chronic cough (n=14) and increased sputum production (n=10). Radiographic abnormalities were observed in 3/18 patients and findings on computed tomography consistent with TO such as beaded intraluminal calcifications and/or increased luminal thickenings were observed in 18/22 patients. Patients were classified into the following categories based on the severity of bronchoscopic findings: Stage I (n=2), Stage II (n=6) and Stage III(n=14). The result that bronchoscopic improvement was observed in 2 patients administered with inhaled corticosteroids suggested that resolution of this disease is possible. Conclusions: TO is a benign disease with slow progression, which could be roughly divided into 3 stages on the basis of the characteristic endoscopic features and histopathologic findings. Chronic inflammation was thought to be more important than the other existing plausible hypotheses in the course of TO. Inhaled corticosteroids might have some impact on patients at Stage I/II.

Keywords: airway obstruction, bronchoscopy, etiology, Tracheobronchopathia osteochondroplastica (TO), treatment

Procedia PDF Downloads 430
2122 A Finite Element Study of Laminitis in Horses

Authors: Naeim Akbari Shahkhosravi, Reza Kakavand, Helen M. S. Davies, Amin Komeili

Abstract:

Equine locomotion and performance are significantly affected by hoof health. One of the most critical diseases of the hoof is laminitis, which can lead to horse lameness in a severe condition. This disease exhibits the mechanical properties degradation of the laminar junction tissue within the hoof. Therefore, it is essential to investigate the biomechanics of the hoof, focusing specifically on excessive and cumulatively accumulated stresses within the laminar junction tissue. For this aim, the current study generated a novel equine hoof Finite Element (FE) model under dynamic physiological loading conditions and employing a hyperelastic material model. Associated tissues of the equine hoof were segmented from computed tomography scans of an equine forelimb, including the navicular bone, third phalanx, sole, frog, laminar junction, digital cushion, and medial- dorsal- lateral wall areas. The inner tissues were connected based on the hoof anatomy, and the hoof was under a dynamic loading over cyclic strides at the trot. The strain distribution on the hoof wall of the model was compared with the published in vivo strain measurements to validate the model. Then the validated model was used to study the development of laminitis. The ultimate stress tolerated by the laminar junction before rupture was considered as a stress threshold. The tissue damage was simulated through iterative reduction of the tissue’s mechanical properties in the presence of excessive maximum principal stresses. The findings of this investigation revealed how damage initiates from the medial and lateral sides of the tissue and propagates through the hoof dorsal area.

Keywords: horse hoof, laminitis, finite element model, continuous damage

Procedia PDF Downloads 146
2121 Role of Imaging in Predicting the Receptor Positivity Status in Lung Adenocarcinoma: A Chapter in Radiogenomics

Authors: Sonal Sethi, Mukesh Yadav, Abhimanyu Gupta

Abstract:

The upcoming field of radiogenomics has the potential to upgrade the role of imaging in lung cancer management by noninvasive characterization of tumor histology and genetic microenvironment. Receptor positivity like epidermal growth factor receptor (EGFR) and anaplastic lymphoma kinase (ALK) genotyping are critical in lung adenocarcinoma for treatment. As conventional identification of receptor positivity is an invasive procedure, we analyzed the features on non-invasive computed tomography (CT), which predicts the receptor positivity in lung adenocarcinoma. Retrospectively, we did a comprehensive study from 77 proven lung adenocarcinoma patients with CT images, EGFR and ALK receptor genotyping, and clinical information. Total 22/77 patients were receptor-positive (15 had only EGFR mutation, 6 had ALK mutation, and 1 had both EGFR and ALK mutation). Various morphological characteristics and metastatic distribution on CT were analyzed along with the clinical information. Univariate and multivariable logistic regression analyses were used. On multivariable logistic regression analysis, we found spiculated margin, lymphangitic spread, air bronchogram, pleural effusion, and distant metastasis had a significant predictive value for receptor mutation status. On univariate analysis, air bronchogram and pleural effusion had significant individual predictive value. Conclusions: Receptor positive lung cancer has characteristic imaging features compared with nonreceptor positive lung adenocarcinoma. Since CT is routinely used in lung cancer diagnosis, we can predict the receptor positivity by a noninvasive technique and would follow a more aggressive algorithm for evaluation of distant metastases as well as for the treatment.

Keywords: lung cancer, multidisciplinary cancer care, oncologic imaging, radiobiology

Procedia PDF Downloads 92
2120 Public Preferences for Lung Cancer Screening in China: A Discrete Choice Experiment

Authors: Zixuan Zhao, Lingbin Du, Le Wang, Youqing Wang, Yi Yang, Jingjun Chen, Hengjin Dong

Abstract:

Objectives: Few results from public attitudes for lung cancer screening are available both in China and abroad. This study aimed to identify preferred lung cancer screening modalities in a Chinese population and predict uptake rates of different modalities. Materials and Methods: A discrete choice experiment questionnaire was administered to 392 Chinese individuals aged 50–74 years who were at high risk for lung cancer. Each choice set had two lung screening options and an option to opt-out, and respondents were asked to choose the most preferred one. Both mixed logit analysis and stepwise logistic analysis were conducted to explore whether preferences were related to respondent characteristics and identify which kinds of respondents were more likely to opt out of any screening. Results: On mixed logit analysis, attributes that were predictive of choice at 1% level of statistical significance included the screening interval, screening venue, and out-of-pocket costs. The preferred screening modality seemed to be screening by low-dose computed tomography (LDCT) + blood test once a year in a general hospital at a cost of RMB 50; this could increase the uptake rate by 0.40 compared to the baseline setting. On stepwise logistic regression, those with no endowment insurance were more likely to opt out; those who were older and housewives/househusbands, and those with a health check habit and with commercial endowment insurance were less likely to opt out from a screening programme. Conclusions: There was considerable variance between real risk and self-perceived risk of lung cancer among respondents, and further research is required in this area. Lung cancer screening uptake can be increased by offering various screening modalities, so as to help policymakers further design the screening modality.

Keywords: lung cancer, screening, China., discrete choice experiment

Procedia PDF Downloads 219
2119 Differential Diagnosis of an Asymptomatic Lesion in Contact with the Bladder

Authors: Angelis P. Barlampas

Abstract:

PURPOSE: Presentation of an interesting finding in an asymptomatic patient. MATERIAL: A patient came at hospital because of dysuric complaints and after a urologist’s prescription of a US exam of the urogenital system. The simple ultrasound examination of the lower abdomen revealed a moderate hypertrophy of the prostate and a solitary large bladder stone. The kidneys were normal. Then, the patient underwent a CT scan, which depicted the bladder stone and, as an incidental finding, a cystic lesion in contact with the upper anterior right surface of the bladder, with mural calcifications. METHOD: Abdominal ultrasound and abdominal computed tomography before and after intravenous contrast administration. RESULTS: The repeated US exam showed a cylindrical cystic lesion with a double wall and two mural hyperechoic foci, with partial posterior shadowing. Blood flow was not recognized on color doppler. The CT exam confirmed the cystic-like anechoic lesion, in the right iliac fossa, with the presence of two foci of mural calcifications. The differential diagnosis includes cases of enteric cyst, intestinal duplication cyst, chronic abscess, urachal cyst, Meckel's diverticulum, bladder diverticulum, old hematoma, thrombosed vascular aneurysm, diverticular abscess, etc. The patient refused surgical removal and is being monitored by ultrasound. CONCLUSIONS: The careful examination of the wider peri-abdominal area, especially during the routine ultrasound examination, can contribute to the identification of important asymptomatic findings. The radiologist must not be solely focused in a certain area of examination, even if the clinical doctor asks so, but should give attention to the neighboring areas, too.

Keywords: enteric cyst, US, CT, urogenital tract, miscellaneous findings

Procedia PDF Downloads 29
2118 The Reduction of CO2 Emissions Level in Malaysian Transportation Sector: An Optimization Approach

Authors: Siti Indati Mustapa, Hussain Ali Bekhet

Abstract:

Transportation sector represents more than 40% of total energy consumption in Malaysia. This sector is a major user of fossils based fuels, and it is increasingly being highlighted as the sector which contributes least to CO2 emission reduction targets. Considering this fact, this paper attempts to investigate the problem of reducing CO2 emission using linear programming approach. An optimization model which is used to investigate the optimal level of CO2 emission reduction in the road transport sector is presented. In this paper, scenarios have been used to demonstrate the emission reduction model: (1) utilising alternative fuel scenario, (2) improving fuel efficiency scenario, (3) removing fuel subsidy scenario, (4) reducing demand travel, (5) optimal scenario. This study finds that fuel balancing can contribute to the reduction of the amount of CO2 emission by up to 3%. Beyond 3% emission reductions, more stringent measures that include fuel switching, fuel efficiency improvement, demand travel reduction and combination of mitigation measures have to be employed. The model revealed that the CO2 emission reduction in the road transportation can be reduced by 38.3% in the optimal scenario.

Keywords: CO2 emission, fuel consumption, optimization, linear programming, transportation sector, Malaysia

Procedia PDF Downloads 388
2117 Experimental Investigation of Performance and Emission Characteristics of Using Acetylene Gas in CI Engine

Authors: S. Sivakumar, Ashwin Bala, S. Prithviraj, K. Panthala Rajakumaran, R. Pradeep, J. Udhayakumar

Abstract:

Studies reveal that acetylene gas derived from hydrolysis of calcium carbide has similar properties to that of diesel. However, the self-ignition temperature of acetylene gas is higher than that of diesel. Early investigations reveal that acetylene gas could be used as alternative fuel mode. In the present work, acetylene gas of 31/min were inducted and diesel was injected into the combustion chamber of a single cylinder air cooled diesel engine. It was observed that the higher calorific value of acetylene gas improves the brake thermal efficiency at full load conditions. The CO and HC emissions were higher at part load conditions as compared to conventional diesel. The Nox emission level was higher and smoke emission was lower during dual fuel mode under all operating conditions. It is concluded that dual fuel mode of acetylene gas and diesel improves the brake thermal efficiency and reduces smoke in diesel engine.

Keywords: acetylene gas, diesel engine, Nox emission, CO emission, HC emission

Procedia PDF Downloads 341
2116 The Impact of the New Head Injury Pathway on the Number of CTs Performed in a Paediatric Population

Authors: Amel M. A. Osman, Roy Mahony, Lisa Dann, McKenna S.

Abstract:

Background: Computed Tomography (CT) is a significant source of radiation in the pediatric population. A new head injury (HI) pathway was introduced in 2021, which altered the previous process of HI being jointly admitted with general pediatrics and surgery to admit these patients under the Emergency Medicine Team. Admitted patients included those with positive CT findings not requiring immediate neurosurgical intervention and those who did not meet current criteria for urgent CT brain as per NICE guidelines but were still symptomatic for prolonged observations. This approach aims to decrease the number of CT scans performed. The main aim is to assess the variation in CT scanning rates since the change in the admitting process. A retrospective review of patients presenting to CHI PECU with HI over 6-month period (01/01/19-31/05/19) compared to a 6-month period post introduction of the new pathway (01/06/2022-31/12/2022). Data was collected from the electronic record databases, symphony, and PACS. Results: In 2019, there were 869 presentations of HI, among which 32 (3.68%) had CT scans performed. 2 (6.25%) of those scanned had positive findings. In 2022, there were 1122 HI presentations, with 47 (4.19%) CT scans performed and positive findings in 5 (10.6%) cases. 57 patients were admitted under the new pathway for observation, with 1 having a CT scan following admission. Conclusion: Quantitative lifetime radiation risks for children are not negligible. While there was no statistically significant reduction in CTs performed amongst HIs presenting to our department, a significant group met the criteria for admission under the PECU consultant for prolonged monitoring. There was also a greater proportion of abnormalities on CT scans performed in 2022, demonstrating improved patient selection for imaging. Further data analysis is ongoing to determine if those who were admitted would have previously been scanned under the old pathway.

Keywords: head injury, CT, admission, guidline

Procedia PDF Downloads 20
2115 Predictors of Pelvic Vascular Injuries in Patients with Pelvic Fractures from Major Blunt Trauma

Authors: Osama Zayed

Abstract:

Aim of the work: The aim of this study is to assess the predictors of pelvic vascular injuries in patients with pelvic fractures from major blunt trauma. Methods: This study was conducted as a tool-assessment study. Forty six patients with pelvic fractures from major blunt trauma will be recruited to the study arriving to department of emergency, Suez Canal University Hospital. Data were collected from questionnaire including; personal data of the studied patients and full medical history, clinical examinations, outcome measures (The Physiological and Operative Severity Score for enumeration of Mortality and morbidity (POSSUM), laboratory and imaging studies. Patients underwent surgical interventions or further investigations based on the conventional standards for interventions. All patients were followed up during conservative, operative and post-operative periods in the hospital for interpretation the predictive scores of vascular injuries. Results: Significant predictors of vascular injuries according to computed tomography (CT) scan include age, male gender, lower Glasgow coma (GCS) scores, occurrence of hypotension, mortality rate, higher physical POSSUM scores, presence of ultrasound collection, type of management, higher systolic blood pressure (SBP) and diastolic blood pressure (DBP) POSSUM scores, presence of abdominal injuries, and poor outcome. Conclusions: There was higher frequency of males than females in the studied patients. There were high probability of morbidity and low probability of mortality among patients. Our study demonstrates that POSSUM score can be used as a predictor of vascular injury in pelvis fracture patients.

Keywords: predictors, pelvic vascular injuries, pelvic fractures, major blunt trauma, POSSUM

Procedia PDF Downloads 312
2114 Adenoid Cystic Carcinoma of the Lacrimal Gland (About a Case)

Authors: H. Hadjeris, R. B. Ghoul, Lekhlaf, M. Nebbal

Abstract:

Introduction: Adenoid cystic carcinomas of the lacrimal gland or orbital cylindroma constitute the second cause of epithelial tumors of this gland. It is a malignant tumor usually developed at the expense of the salivary glands; its orbital location is exceptional. It is a rare clinical entity, formidable by its malignancy and local aggressiveness; the recurrence rate is high. Materials and methods: Clinical case: 63 years old woman who presents with irreducible no pulsatile painful left exophthalmos with inflammatory chemosis and a decrease in visual acuity with a moderate intracranial hypertension syndrome that has been evolving for 03 months. Antecedent; a biopsy of the tumor was made; the histological examination was in favor of an adenoid cystic carcinoma of the lacrimal gland. Lesion assessment: computed tomography and brain MRI: show an intra and extra-conical mass; with sinus (ethmoido-frontal) and cerebral (left frontal) extension strongly enhanced after injection of contrast product surrounded by edema around the lesion, associated with left frontal bone lysis extension assessment: unremarkable treatment: Patient operated by left frontotemporal approach, a total exenteration was performed with macroscopically complete excision of the frontal lesion and wide frontal craniectomy with craniofacial reconstruction, followed by complementary radiotherapy. Results: The patient was seen again after 3 months in consultation; she does not present any signs in favor of a recurrence. Conclusion: Adenoid cystic carcinomas of the lacrimal gland are rare malignant tumors; they are very infiltrating and invasive. The prognosis is strongly linked to the treatment time.

Keywords: adenoid cystic, lacrimal gland, orbital location, fronto-temporal approac

Procedia PDF Downloads 41
2113 Study on the Relationship between the Emission Property of Barium-Tungsten Cathode and Micro-Area Activity

Authors: Zhen Qin, Yufei Peng, Jianbei Li, Jidong Long

Abstract:

In order to study the activity of the coated aluminate barium-tungsten cathodes during activation, aging, poisoning and long-term use. Through a set of hot-cathode micro-area emission uniformity study device, we tested the micro-area emission performance of the cathode under different conditions. The change of activity of cathode micro-area was obtained. The influence of micro-area activity on the performance of the cathode was explained by the ageing model of barium-tungsten cathode. This helps to improve the design and process of the cathode and can point the way in finding the factors that affect life in the cathode operation.

Keywords: barium-tungsten cathode, ageing model, micro-area emission, emission uniformity

Procedia PDF Downloads 383
2112 Optimization and Evaluation of 177lu-Dotatoc as a Potential Agent for Peptide Receptor Radionuclide Therapy

Authors: H. Yousefnia, MS. Mousavi-Daramoroudi, S. Zolghadri, F. Abbasi-Davani

Abstract:

High expression of somatostatin receptors on a wide range of human tumours makes them as potential targets for peptide receptor radionuclide tomography. A series of octreotide analogues were synthesized while [DOTA-DPhe1, Tyr3]octreotide (DOTATOC) indicated advantageous properties in tumour models. In this study, 177Lu-DOTATOC was prepared with the radiochemical purity of higher than 99% in 30 min at the optimized condition. Biological behavior of the complex was studied after intravenous injection into the Syrian rats. Major difference uptake was observed compared to 177LuCl3 solution especially in somatostatin receptor-positive tissues such as pancreas and adrenal.

Keywords: Biodistribution, 177Lu, Octreotide, Syrian rats

Procedia PDF Downloads 416
2111 Discrete Element Simulations of Composite Ceramic Powders

Authors: Julia Cristina Bonaldo, Christophe L. Martin, Severine Romero Baivier, Stephane Mazerat

Abstract:

Alumina refractories are commonly used in steel and foundry industries. These refractories are prepared through a powder metallurgy route. They are a mixture of hard alumina particles and graphite platelets embedded into a soft carbonic matrix (binder). The powder can be cold pressed isostatically or uniaxially, depending on the application. The compact is then fired to obtain the final product. The quality of the product is governed by the microstructure of the composite and by the process parameters. The compaction behavior and the mechanical properties of the fired product depend greatly on the amount of each phase, on their morphology and on the initial microstructure. In order to better understand the link between these parameters and the macroscopic behavior, we use the Discrete Element Method (DEM) to simulate the compaction process and the fracture behavior of the fired composite. These simulations are coupled with well-designed experiments. Four mixes with various amounts of Al₂O₃ and binder were tested both experimentally and numerically. In DEM, each particle is modelled and the interactions between particles are taken into account through appropriate contact or bonding laws. Here, we model a bimodal mixture of large Al₂O₃ and small Al₂O₃ covered with a soft binder. This composite is itself mixed with graphite platelets. X-ray tomography images are used to analyze the morphologies of the different components. Large Al₂O₃ particles and graphite platelets are modelled in DEM as sets of particles bonded together. The binder is modelled as a soft shell that covers both large and small Al₂O₃ particles. When two particles with binder indent each other, they first interact through this soft shell. Once a critical indentation is reached (towards the end of compaction), hard Al₂O₃ - Al₂O₃ contacts appear. In accordance with experimental data, DEM simulations show that the amount of Al₂O₃ and the amount of binder play a major role for the compaction behavior. The graphite platelets bend and break during the compaction, also contributing to the macroscopic stress. Firing step is modeled in DEM by ascribing bonds to particles which contact each other after compaction. The fracture behavior of the compacted mixture is also simulated and compared with experimental data. Both diametrical tests (Brazilian tests) and triaxial tests are carried out. Again, the link between the amount of Al₂O₃ particles and the fracture behavior is investigated. The methodology described here can be generalized to other particulate materials that are used in the ceramic industry.

Keywords: cold compaction, composites, discrete element method, refractory materials, x-ray tomography

Procedia PDF Downloads 114
2110 Spontaneous Reformation of Dehiscent Frontal Sinus Wall after Endoscopic Removal of Mucocele

Authors: Tan Dexian Arthur, James Wei Ming Kwek, Ian Loh, Lee Tee Sin

Abstract:

Statement of the Problem: Mucoceles most commonly affect the frontal sinus, which results from chronic obstruction of the sinus ostium or cystic dilatation of mucous glands with ductal obstruction. They are known to cause bony erosion of the sinus walls, which can lead to large defects. These defects were typically managed by obliteration or cranialization of the frontal sinus. Although short term outcomes of conservative management of significant posterior table defects from fractures are promising, there have been no studies on the long-term outcomes of large dehiscences in the posterior wall of the frontal sinus. Methodology & Findings : Computed Tomography (CT) Paranasal Sinuses images were analyzed and found complete spontaneous osteogenesis of a large dehiscent frontal sinus posterior wall, secondary to a large mucocele, 9 years from functional endoscopic sinus surgery with the defect managed conservatively. Conclusion & Significance: The dura is well known for its osteogenic properties. Prior studies have showed that dura could induce osteogenesis in cutaneous tissue in the absence of other central nervous system structures. It was also demonstrated that osteogenesis and chondrogenesis were possible in zygomatic fractures by transplanting neonatal dura grafts to the bony defects in rats. Extrapolating from these studies, the authors postulate that the presence of dura beneath the bony deformity of the posterior frontal sinus wall had likely initiated the osteogenesis and restored the bony defect in the patient. In our literature review, we did not find any reports of spontaneous osteogenesis of large frontal sinus defects. While our experience is incidental, it reinforces the osteogenetic potential of an intact dura and further highlights that selected large defects of the posterior wall of the frontal sinus can be conservatively managed.

Keywords: paranasal sinus mucocele, mucocele, osteogenesis, dehiscence

Procedia PDF Downloads 40
2109 Base Deficit Profiling in Patients with Isolated Blunt Traumatic Brain Injury – Correlation with Severity and Outcomes

Authors: Shahan Waheed, Muhammad Waqas, Asher Feroz

Abstract:

Objectives: To determine the utility of base deficit in traumatic brain injury in assessing the severity and to correlate with the conventional computed tomography scales in grading the severity of head injury. Methodology: Observational cross-sectional study conducted in a tertiary care facility from 1st January 2010 to 31st December 2012. All patients with isolated traumatic brain injury presenting within 24 hours of the injury to the emergency department were included in the study. Initial Glasgow Coma Scale and base deficit values were taken at presentation, the patients were followed during their hospital stay and CT scan brain findings were recorded and graded as per the Rotterdam scale, the findings were cross-checked by a radiologist, Glasgow Outcome Scale was taken on last follow up. Outcomes were dichotomized into favorable and unfavorable outcomes. Continuous variables with normal and non-normal distributions are reported as mean ± SD. Categorical variables are presented as frequencies and percentages. Relationship of the base deficit with GCS, GOS, CT scan brain and length of stay was calculated using Spearman`s correlation. Results: 154 patients were enrolled in the study. Mean age of the patients were 30 years and 137 were males. The severity of brain injuries as per the GCS was 34 moderate and 109 severe respectively. 34 percent of the total has an unfavorable outcome with a mean of 18±14. The correlation was significant at the 0.01 level with GCS on presentation and the base deficit 0.004. The correlation was not significant between the Rotterdam CT scan brain findings, length of stay and the base deficit. Conclusion: The base deficit was found to be a good predictor of severity of brain injury. There was no association of the severity of injuries on the CT scan brain as per the Rotterdam scale and the base deficit. Further studies with large sample size are needed to further evaluate the associations.

Keywords: base deficit, traumatic brain injury, Rotterdam, GCS

Procedia PDF Downloads 411
2108 Effects of China's Urban Form on Urban Carbon Emission

Authors: Lu Lin

Abstract:

Urbanization has reshaped physical environment, energy consumption and carbon emission of the urban area. China is a typical developing country under a rapid urbanization process and is the world largest carbon emission country. This study aims to explore the correlation between urban form and carbon emission caused by urban energy consumption in China. 287 provincial-level and prefecture-level cities are studied in 2000, 2005, and 2010. Compact ratio index, shape index, and fractal dimension index are used to quantify urban form. Geographically weighted regression (GWR) model is employed to explore the relationship between urban form, energy consumption, and related carbon emission. The results show the average compact ratio index decreased from 2000 to 2010 which indicates urban in China sprawled. The average fractal dimension index increases by 3%, indicating the spatial layouts of China's cities were more complicated. The results by the GWR model show that shape index and fractal dimension index had a non-significant relationship with carbon emission by urban energy consumption. However, compact urban form reduced carbon emission. The findings of this study will help policy-makers make sustainable urban planning and reduce urban carbon emission.

Keywords: carbon emission, GWR model, urban energy consumption, urban form

Procedia PDF Downloads 314
2107 Rare Differential Diagnostic Dilemma

Authors: Angelis P. Barlampas

Abstract:

Theoretical background Disorders of fixation and rotation of the large intestine, result in the existence of its parts in ectopic anatomical positions. In case of symptomatology, the clinical picture is complicated by the possible symptomatology of the neighboring anatomical structures and a differential diagnostic problem arises. Target The purpose of this work is to demonstrate the difficulty of revealing the real cause of abdominal pain, in cases of anatomical variants and the decisive contribution of imaging and especially that of computed tomography. Methods A patient came to the emergency room, because of acute pain in the right hypochondrium. Clinical examination revealed tenderness in the gallbladder area and a positive Murphy's sign. An ultrasound exam depicted a normal gallbladder and the patient was referred for a CT scan. Results Flexible, unfixed ascending colon and cecum, located in the anatomical region of the right mesentery. Opacities of the surrounding peritoneal fat and a small linear concentration of fluid can be seen. There was an appendix of normal anteroposterior diameter with the presence of air in its lumen and without clear signs of inflammation. There was an impression of possible inflammatory swelling at the base of the appendix, (DD phenomenon of partial volume; e.t.c.). Linear opacities of the peritoneal fat in the region of the second loop of the duodenum. Multiple diverticula throughout the colon. Differential Diagnosis The differential diagnosis includes the following: Inflammation of the base of the appendix, diverticulitis of the cecum-ascending colon, a rare case of second duodenal loop ulcer, tuberculosis, terminal ileitis, pancreatitis, torsion of unfixed cecum-ascending colon, embolism or thrombosis of a vascular intestinal branch. Final Diagnosis There is an unfixed cecum-ascending colon, which is exhibiting diverticulitis.

Keywords: unfixed cecum-ascending colon, abdominal pain, malrotation, abdominal CT, congenital anomalies

Procedia PDF Downloads 29
2106 Research of Intrinsic Emittance of Thermal Cathode with Emission Nonuniformity

Authors: Yufei Peng, Zhen Qin, Jianbe Li, Jidong Long

Abstract:

The thermal cathode is widely used in accelerators, FELs and kinds of vacuum electronics. However, emission nonuniformity exists due to surface profile, material distribution, temperature variation, crystal orientation, etc., which will cause intrinsic emittance growth, brightness decline, envelope size augment, device performance deterioration or even failure. To understand how emittance is manipulated by emission nonuniformity, an intrinsic emittance model consisting of contributions from macro and micro surface nonuniformity is developed analytically based on general thermal emission model at temperature limited regime according to a real 3mm cathode. The model shows relative emittance increased about 50% due to temperature variation, and less than 5% from several kinds of micro surface nonuniformity which is much smaller than other research. Otherwise, we also calculated emittance growth combining with Monte Carlo method and PIC simulation, experiments of emission uniformity and emittance measurement are going to be carried out separately.

Keywords: thermal cathode, electron emission fluctuation, intrinsic emittance, surface nonuniformity, cathode lifetime

Procedia PDF Downloads 267
2105 Geometric Imperfections in Lattice Structures: A Simulation Strategy to Predict Strength Variability

Authors: Xavier Lorang, Ahmadali Tahmasebimoradi, Chetra Mang, Sylvain Girard

Abstract:

The additive manufacturing processes (e.g. selective laser melting) allow us to produce lattice structures which have less weight, higher impact absorption capacity, and better thermal exchange property compared to the classical structures. Unfortunately, geometric imperfections (defects) in the lattice structures are by-products results of the manufacturing process. These imperfections decrease the lifetime and the strength of the lattice structures and alternate their mechanical responses. The objective of the paper is to present a simulation strategy which allows us to take into account the effect of the geometric imperfections on the mechanical response of the lattice structure. In the first part, an identification method of geometric imperfection parameters of the lattice structure based on point clouds is presented. These point clouds are based on tomography measurements. The point clouds are fed into the platform LATANA (LATtice ANAlysis) developed by IRT-SystemX to characterize the geometric imperfections. This is done by projecting the point clouds of each microbeam along the beam axis onto a 2D surface. Then, by fitting an ellipse to the 2D projections of the points, the geometric imperfections are characterized by introducing three parameters of an ellipse; semi-major/minor axes and angle of rotation. With regard to the calculated parameters of the microbeam geometric imperfections, a statistical analysis is carried out to determine a probability density law based on a statistical hypothesis. The microbeam samples are randomly drawn from the density law and are used to generate lattice structures. In the second part, a finite element model for the lattice structure with the simplified geometric imperfections (ellipse parameters) is presented. This numerical model is used to simulate the generated lattice structures. The propagation of the uncertainties of geometric imperfections is shown through the distribution of the computed mechanical responses of the lattice structures.

Keywords: additive manufacturing, finite element model, geometric imperfections, lattice structures, propagation of uncertainty

Procedia PDF Downloads 161
2104 Spherical Nonlinear Wave Propagation in Relativistic Quantum Plasma

Authors: Alireza Abdikian

Abstract:

By assuming a quantum relativistic degenerate electron-positron (e-p) plasma media, the nonlinear acoustic solitary propagation in the presence of the stationary ions for neutralizing the plasma background of bounded cylindrical geometry was investigated. By using the standard reductive perturbation technique with cooperation the quantum hydrodynamics model for the e-p fluid, the spherical Kadomtsev-Petviashvili equation was derived for small but finite amplitude waves and was given the solitary wave solution for the parameters relevant for dense astrophysical objects such as white dwarf stars. By using a suitable coordinate transformation and using improved F-expansion technique, the SKP equation can be solved analytically. The numerical results reveal that the relativistic effects lead to propagate the electrostatic bell shape structures and by increasing the relativistic effects, the amplitude and the width of the e-p acoustic solitary wave will decrease.

Keywords: Electron-positron plasma, Acoustic solitary wave, Relativistic plasmas, the spherical Kadomtsev-Petviashvili equation

Procedia PDF Downloads 112
2103 Approaches for Minimizing Radioactive Tritium and ¹⁴C in Advanced High Temperature Gas-Cooled Reactors

Authors: Longkui Zhu, Zhengcao Li

Abstract:

High temperature gas-cooled reactors (HTGRs) are considered as one of the next-generation advanced nuclear reactors, in which porous nuclear graphite is used as neutron moderators, reflectors, structure materials, and cooled by inert helium. Radioactive tritium and ¹⁴C are generated in terms of reactions of thermal neutrons and ⁶Li, ¹⁴N, ¹⁰B impurely within nuclear graphite and the coolant during HTGRs operation. Currently, hydrogen and nitrogen diffusion behavior together with nuclear graphite microstructure evolution were investigated to minimize the radioactive waste release, using thermogravimetric analysis, X-ray computed tomography, the BET and mercury standard porosimetry methods. It is found that the peak value of graphite weight loss emerged at 573-673 K owing to nitrogen diffusion from graphite pores to outside when the system was subjected to vacuum. Macropore volume became larger while porosity for mesopores was smaller with temperature ranging from ambient temperature to 1073 K, which was primarily induced by coalescence of the subscale pores. It is suggested that the porous nuclear graphite should be first subjected to vacuum at 573-673 K to minimize the nitrogen and the radioactive 14°C before operation in HTGRs. Then, results on hydrogen diffusion show that the diffusible hydrogen and tritium could permeate into the coolant with diffusion coefficients of > 0.5 × 10⁻⁴ cm²·s⁻¹ at 50 bar. As a consequence, the freshly-generated diffusible tritium could release quickly to outside once formed, and an effective approach for minimizing the amount of radioactive tritium is to make the impurity contents extremely low in nuclear graphite and the coolant. Besides, both two- and three-dimensional observations indicate that macro and mesopore volume along with total porosity decreased with temperature at 50 bar on account of synergistic effects of applied compression strain, sharpened pore morphology, and non-uniform temperature distribution.

Keywords: advanced high temperature gas-cooled reactor, hydrogen and nitrogen diffusion, microstructure evolution, nuclear graphite, radioactive waste management

Procedia PDF Downloads 287
2102 Clinicoradiographic Evaluation of Polymer of Injectable Platelet-Rich Fibrin (i-PRF) and Hydroxyapatite as Bone Graft Substitute in Maxillomandibular Bony Defects: A Double-Blinded Randomized Control Trial

Authors: Naqoosh Haidry

Abstract:

Objective & Goal: Enucleation of the maxillomandibular cysts will lead to the creation of post-surgical bone defects which may take more than a year for complete bone healing. The use of bone grafts is common to aid bone regeneration in large defects. The study aimed to evaluate the healing and bone formation capabilities of polymer of injectable platelet fibrin (i-PRF) and hydroxyapatite (HA) as bone graft substitute in maxilla-mandibular postsurgical defects compared to hydroxyapatite alone. The primary objective was to find out the clinical and radiological assessment of healing postoperatively and compare the outcome of both groups. Material and Methods: After surgical enucleation of 19 maxillomandibular cysts/tumors, either HA or HA+ i-PRF graft was adapted to the defect. Clinical outcome variables such as pain (VAS score), edema, and mucosal color were evaluated on postoperative days 01, 03, and 07 while radiological outcome variables such as volume of defect (cc), density of new bone (HU) on computed tomography were evaluated at 2nd and 4th month. The results obtained were tabulated and compared with the inferential analysis. Results: Clinical parameters seem to be better in the HA + i-PRF group, but the result was non-significant. Radiologically, the mean healing ratios were significantly greater in the HA + i-PRF group (63.5 ± 2.34 at 2nd month, 90.3 ± 7.32 at 4th month) compared to the HA group (57.2 ± 5.21at 2nd month, 80.8 ± 5.33 at 4th month). When comparing the mean density of new bone, there was a statistically significant difference with a mean difference of 95.2 HU more in the HA + i-PRF (623 HU ± 42.9) compared to the HA group (528 HU ± 96.5) in 2nd month. Conclusion: The polymer of i-PRF and HA prepared as the sticky bone yields faster and better bone healing in post-enucleation maxillomandibular bony defects as compared to hydroxyapatite alone based on radiological findings till four months.

Keywords: bone defect, density of new bone, hydroxyapatite, injectable platelet rich fibrin, maxillomandibular cysts, surgical defect

Procedia PDF Downloads 18
2101 Bearing Condition Monitoring with Acoustic Emission Techniques

Authors: Faisal AlShammari, Abdulmajid Addali

Abstract:

Monitoring the conditions of rotating machinery as bearing is important in order to improve its stability of works. Acoustic emission (AE) and vibration analysis are some of the most accomplished techniques used for this purpose. Acoustic emission has the ability to detect the initial phase of component degradation. Moreover, it has been observed that the success of vibration analysis does not take place below 100 rpm rotational speed. This because the energy generated below 100 rpm rotational speed is not detectable using conventional vibration. From this pint, this paper has presented a focused review of using acoustic emission techniques for monitoring bearings condition.

Keywords: condition monitoring, stress wave analysis, low-speed bearings, bearing defect diagnosis

Procedia PDF Downloads 285
2100 Morphology and Permeability of Biomimetic Cellulose Triacetate-Impregnated Membranes: in situ Synchrotron Imaging and Experimental Studies

Authors: Amira Abdelrasoul

Abstract:

This study aimed to ascertain the controlled permeability of biomimetic cellulose triacetate (CTA) membranes by investigating the electrical oscillatory behavior across impregnated membranes (IM). The biomimetic CTA membranes were infused with a fatty acid to induce electrical oscillatory behavior and, hence, to ensure controlled permeability. In situ synchrotron radiation micro-computed tomography (SR-μCT) at the BioMedical Imaging and Therapy (BMIT) Beamline at the Canadian Light Source (CLS) was used to evaluate the main morphology of IMs compared to neat CTA membranes to ensure fatty acid impregnation inside the pores of the membrane matrices. A monochromatic beam at 20 keV was used for the visualization of the morphology of the membrane. The X-ray radiographs were recorded by means of a beam monitor AA-40 (500 μm LuAG scintillator, Hamamatsu, Japan) coupled with a high-resolution camera, providing a pixel size of 5.5 μm and a field of view (FOV) of 4.4 mm × 2.2 mm. Changes were evident in the phase transition temperatures of the impregnated CTA membrane at the melting temperature of the fatty acid. The pulsations of measured voltages were related to changes in the salt concentration of KCl in the vicinity of the electrode. Amplitudes and frequencies of voltage pulsations were dependent on the temperature and concentration of the KCl solution, which controlled the permeability of the biomimetic membranes. The presented smart biomimetic membrane successfully combined porous polymer support and impregnating liquid not only imitate the main barrier properties of the biological membranes but could be easily modified to achieve some new properties, such as facilitated and active transport, regulation by chemical, physical and pharmaceutical factors. These results open new frontiers for the facilitation and regulation of active transport and permeability through biomimetic smart membranes for a variety of biomedical and drug delivery applications.

Keywords: biomimetic, membrane, synchrotron, permeability, morphology

Procedia PDF Downloads 76
2099 Electrochemotherapy of Portal Vein Tumor Thrombus as Dowstaging to Liver Transplantation

Authors: Luciano Tarantino, Emanuele Balzano, Paolo Tarantino, Riccardo Aurelio Nasto, Aurelio Nasto

Abstract:

Liver transplantation (OLT) is contraindicate in Portal Vein tumor Thrombosis (PVTT) from Hepatocellular Carcinoma at hepatic hilum(pH-HCC) Surgery,Thermal ablation and chemotherapy show poorer outcomes Electrochemotherapy (ECT) has been successfully used in patients with pH-HCC with PVTT. We report the results of ECT as downstaging aimed to definitive cure by OLT. F.P. 53 years HBV related Cirrhosis Child-Pugh B7 class; EGDS F2 aesophageal Varices. Diabetes. April 2016 : Enhanced Computed Tomography (CT) detected HCC(n.3 nodules in VII-VIII-VI;diameter range=25 cm) and PVTT of right portal vein. The patient was considered ineligible for OLT. May 2016: first ablation session with percutaneous Radiofrequency-ablation(RFA) of 3 HCC-nodules . August 2016: second ablation session with ECT of PVTT. CT october 2016: disappearance of PVTT and patent right portal vein. No intraparenchymal recurrence. CT march 2017: No recurrence in portal vein and in the left lobe. local recurrence in the VII-VIII segments. May 2017 : transarterial chemoembolization (TACE) of right lobe recurrences. CT October 2017: patent right portal vein. No recurrence. The patient was reconsidered for OLT. He underwent OLT in April 2018. At 36-months follow-up , no intrahepatic recurrence of HCC occurred. March 2021: enhanced CT and PET/CT detected a single small nodule (1.5 cm) uptaking tracer in the left upper pulmonary lobe, no hepatic recurrence . CT-guided FNB showed metastasis from HCC . June 2021: left lung upper lobectomy . At the current time the patient is alive and recurrence-free at 64 months follow-up. ECT Could be aneffective technique as pre-OLT dowstaging in HCC with PVTT.

Keywords: liver tumor ablation, interventional ultrasound, electrochemotherapy, liver transplantation

Procedia PDF Downloads 84