Search results for: left ventricle assist device (LVAD)
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 4104

Search results for: left ventricle assist device (LVAD)

3924 Device for Thermal Depolymerisation of Organic Substrates Prior to Methane Fermentation

Authors: Marcin Dębowski, Mirosław Krzemieniewski, Marcin Zieliński

Abstract:

This publication presents a device designed to depolymerise and structurally change organic substrate, for use in agricultural biogas plants or sewage treatment plants. The presented device consists of a heated tank equipped with an inlet valve for the crude substrate and an outlet valve for the treated substrate. The system also includes a gas conduit, which is at its tip equipped with a high-pressure solenoid valve and a vacuum relief solenoid valve. A conduit behind the high-pressure solenoid valve connects to the vacuum tank equipped with the outlet valve. The substrate introduced into the device is exposed to agents such as high temperature and cavitation produced by abrupt, short-term reduction of pressure within the heated tank. The combined effect of these processes is substrate destruction rate increase of about 20% when compared to using high temperature alone, and about 30% when compared to utilizing only cavitation. Energy consumption is greatly reduced, as the pressure increase is generated by heating the substrate. Thus, there is a 18% reduction of energy consumption when compared to a device designed to destroy substrate through high temperature alone, and a 35% reduction if compared to using cavitation as the only means of destruction.

Keywords: thermal depolymerisation, organic substrate, biogas, pre-treatment

Procedia PDF Downloads 557
3923 Design and Implementation of a Nano-Power Wireless Sensor Device for Smart Home Security

Authors: Chia-Chi Chang

Abstract:

Most battery-driven wireless sensor devices will enter in sleep mode as soon as possible to extend the overall lifetime of a sensor network. It is necessary to turn off unnecessary radio and peripheral functions, especially the radio unit always consumes more energy than other components during wireless communication. The microcontroller is the most important part of the wireless sensor device. It is responsible for the manipulation of sensing data and communication protocols. The microcontroller always has different sleep modes, each with a different level of energy usage. The deeper the sleep, the lower the energy consumption. Most wireless sensor devices can only enter the sleep mode: the external low-frequency oscillator is still running to wake up the sleeping microcontroller when the sleep timer expires. In this paper, our sensor device can enter the extended sleep mode: none of the oscillator is running and the wireless sensor device has the nanoampere consumption and self-awaking ability. Finally, these wireless sensor devices were deployed in a smart home security network.

Keywords: wireless sensor network, battery-driven, sleep mode, home security

Procedia PDF Downloads 296
3922 New Modification Negative Stiffness Device with Constant Force-Displacement Characteristic for Seismic Protection of Structures

Authors: Huan Li, Jianchun Li, Yancheng Li, Yang Yu

Abstract:

As a seismic protection method of civil and engineering structures, weakening and damping is effective during the elastic region, while it somehow leads to the early yielding of the entire structure accompanying with large excursions and permanent deformations. Adaptive negative stiffness device is attractive for realizing yielding property without changing the stiffness of the primary structure. In this paper, a new modification negative stiffness device (MNSD) with constant force-displacement characteristic is proposed by combining a magnetic negative stiffness spring, a piecewise linear positive spring and a passive damper with a certain adaptive stiffness device. The proposed passive control MNSD preserves no effect under small excitation. When the displacement amplitude increases beyond the pre-defined yielding point, the force-displacement characteristics of the system with MNSD will keep constant. The seismic protection effect of the MNSD is evaluated by employing it to a single-degree-of-freedom system under sinusoidal excitation, and real earthquake waves. By comparative analysis, the system with MNSD performs better on reducing acceleration and displacement response under different displacement amplitudes than the scenario without it and the scenario with unmodified certain adaptive stiffness device.

Keywords: negative stiffness, adaptive stiffness, weakening and yielding, constant force-displacement characteristic

Procedia PDF Downloads 141
3921 Signal On-Off Ratio and Output Frequency Analysis of Semiconductor Electron-Interference Device

Authors: Tomotaka Aoki, Isao Tomita

Abstract:

We examined the on-off ratio and frequency components of output signals from an electron-interference device made of GaAs/AlₓGa₁₋ₓAs by solving the time-dependent Schrödinger's equation on conducting electrons in the channel waveguide of the device. For electron-wave modulation, a periodic voltage of frequency f was applied to the channel. Furthermore, we examined the voltage-amplitude dependence of the signals in time and frequency domains and found that large applied voltage deformed the output-signal waveform and created additional side modes (frequencies) near the modulation frequency f and that there was a trade-off between on-off ratio and side-mode creation.

Keywords: electrical conduction, electron interference, frequency spectrum, on-off ratio

Procedia PDF Downloads 113
3920 Hemocompatible Thin-Film Materials Recreating the Structure of the Cell Niches with High Potential for Endothelialization

Authors: Roman Major, Klaudia Trembecka- Wojciga, Juergen Markus Lackner, Boguslaw Major

Abstract:

The future and the development of science is therefore seen in interdisciplinary areas such as bio medical engineering. Self-assembled structures, similar to stem cell niches would inhibit fast division process and subsequently capture the stem cells from the blood flow. By means of surface topography and the stiffness as well as micro structure progenitor cells should be differentiated towards the formation of endothelial cells monolayer which effectively will inhibit activation of the coagulation cascade. The idea of the material surface development met the interest of the clinical institutions, which support the development of science in this area and are waiting for scientific solutions that could contribute to the development of heart assist systems. This would improve the efficiency of the treatment of patients with myocardial failure, supported with artificial heart assist systems. Innovative materials would enable the redesign, in the post project activity, construction of ventricular heart assist.

Keywords: bio-inspired materials, electron microscopy, haemocompatibility, niche-like structures, thin coatings

Procedia PDF Downloads 467
3919 Uncovering the Role of Crystal Phase in Determining Nonvolatile Flash Memory Device Performance Based on 2D Van Der Waals Heterostructures

Authors: Yunpeng Xia, Jiajia Zha, Haoxin Huang, Hau Ping Chan, Chaoliang Tan

Abstract:

Although the crystal phase of two-dimensional (2D) transition metal dichalcogenides (TMDs) has been proven to play an essential role in fabricating high-performance electronic devices in the past decade, its effect on the performance of 2D material-based flash memory devices still remains unclear. Here, we report the exploration of the effect of MoTe₂ in different phases as the charge trapping layer on the performance of 2D van der Waals (vdW) heterostructure-based flash memory devices, where the metallic 1T′-MoTe₂ or semiconducting 2H-MoTe₂ nanoflake is used as the floating gate. By conducting comprehensive measurements on the two kinds of vdW heterostructure-based devices, the memory device based on MoS2/h-BN/1T′-MoTe₂ presents much better performance, including a larger memory window, faster switching speed (100 ns) and higher extinction ratio (107), than that of the device based on MoS₂/h-BN/2H-MoTe₂ heterostructure. Moreover, the device based on MoS₂/h-BN/1T′-MoTe₂ heterostructure also shows a long cycle (>1200 cycles) and retention (>3000 s) stability. Our study clearly demonstrates that the crystal phase of 2D TMDs has a significant impact on the performance of nonvolatile flash memory devices based on 2D vdW heterostructures, which paves the way for the fabrication of future high-performance memory devices based on 2D materials.

Keywords: crystal Phase, 2D van der Waals heretostructure, flash memory device, floating gate

Procedia PDF Downloads 32
3918 A Theoretical Approach on Electoral Competition, Lobby Formation and Equilibrium Policy Platforms

Authors: Deepti Kohli, Meeta Keswani Mehra

Abstract:

The paper develops a theoretical model of electoral competition with purely opportunistic candidates and a uni-dimensional policy using the probability voting approach while focusing on the aspect of lobby formation to analyze the inherent complex interactions between centripetal and centrifugal forces and their effects on equilibrium policy platforms. There exist three types of agents, namely, Left-wing, Moderate and Right-wing who comprise of the total voting population. Also, it is assumed that the Left and Right agents are free to initiate a lobby of their choice. If initiated, these lobbies generate donations which in turn can be contributed to one (or both) electoral candidates in order to influence them to implement the lobby’s preferred policy. Four different lobby formation scenarios have been considered: no lobby formation, only Left, only Right and both Left and Right. The equilibrium policy platforms, amount of individual donations by agents to their respective lobbies and the contributions offered to the electoral candidates have been solved for under each of the above four cases. Since it is assumed that the agents cannot coordinate each other’s actions during the lobby formation stage, there exists a probability with which a lobby would be formed, which is also solved for in the model. The results indicate that the policy platforms of the two electoral candidates converge completely under the cases of no lobby and both (extreme) formations but diverge under the cases of only one (Left or Right) lobby formation. This is because in the case of no lobby being formed, only the centripetal forces (emerging from the election-winning aspect) are present while in the case of both extreme (Left-wing and Right-wing) lobbies being formed, centrifugal forces (emerging from the lobby formation aspect) also arise but cancel each other out, again resulting in a pure policy convergence phenomenon. In contrast, in case of only one lobby being formed, both centripetal and centrifugal forces interact strategically, leading the two electoral candidates to choose completely different policy platforms in equilibrium. Additionally, it is found that in equilibrium, while the donation by a specific agent type increases with the formation of both lobbies in comparison to when only one lobby is formed, the probability of implementation of the policy being advocated by that lobby group falls.

Keywords: electoral competition, equilibrium policy platforms, lobby formation, opportunistic candidates

Procedia PDF Downloads 319
3917 Operating System Support for Mobile Device Thermal Management and Performance Optimization in Augmented Reality Applications

Authors: Yasith Mindula Saipath Wickramasinghe

Abstract:

Augmented reality applications require a high processing power to load, render and live stream high-definition AR models and virtual scenes; it also requires device sensors to work excessively to coordinate with internal hardware, OS and give the expected outcome in advance features like object detection, real time tracking, as well as voice and text recognition. Excessive thermal generation due to these advanced functionalities has become a major research problem as it is unbearable for smaller mobile devices to manage such heat increment and battery drainage as it causes physical harm to the devices in the long term. Therefore, effective thermal management is one of the major requirements in Augmented Reality application development. As this paper discusses major causes for this issue, it also provides possible solutions in the means of operating system adaptations as well as further research on best coding practises to optimize the application performance that reduces thermal excessive thermal generation.

Keywords: augmented reality, device thermal management, GPU, operating systems, device I/O, overheating

Procedia PDF Downloads 106
3916 Integrating Ergonomics at Design Stage in Development of Continuous Passive Motion Machine

Authors: Mahesh S. Harne, Sunil V. Deshmukh

Abstract:

A continuous passive motion machine improves and helps the patient to restore range of motion in various physiotherapy activities. The paper presents a concept for portable CPM. The device is used for various joint for upper and lower body extremities. The device is designed so that the active and passive motion is incorporated. During development, the physiotherapist and patient need is integrated with designer aspects. Various tools such as Analytical Higher Hierarchy process (AHP) and Quality Function Deployment (QFD) is used to integrate the need at the design stage. With market survey of various commercial CPM the gaps are identified, and efforts are made to fill the gaps with ergonomic need. Indian anthropomorphic dimension is referred. The device is modular to best suit for all the anthropomorphic need of different human. Experimentation is carried under the observation of physiotherapist and doctor on volunteer patient. We reported better results are compare to conventional CPM with comfort and less pain. We concluded that the concept will be helpful to reduces therapy cost and wide utility of device for various joint and physiotherapy exercise.

Keywords: continuous passive motion machine, ergonomics, physiotherapy, quality function deployment

Procedia PDF Downloads 169
3915 Design of the Compliant Mechanism of a Biomechanical Assistive Device for the Knee

Authors: Kevin Giraldo, Juan A. Gallego, Uriel Zapata, Fanny L. Casado

Abstract:

Compliant mechanisms are designed to deform in a controlled manner in response to external forces, utilizing the flexibility of their components to store potential elastic energy during deformation, gradually releasing it upon returning to its original form. This article explores the design of a knee orthosis intended to assist users during stand-up motion. The orthosis makes use of a compliant mechanism to balance the user’s weight, thereby minimizing the strain on leg muscles during standup motion. The primary function of the compliant mechanism is to store and exchange potential energy, so when coupled with the gravitational potential of the user, the total potential energy variation is minimized. The design process for the semi-rigid knee orthosis involved material selection and the development of a numerical model for the compliant mechanism seen as a spring. Geometric properties are obtained through the numerical modeling of the spring once the desired stiffness and safety factor values have been attained. Subsequently, a 3D finite element analysis was conducted. The study demonstrates a strong correlation between the maximum stress in the mathematical model (250.22 MPa) and the simulation (239.8 MPa), with a 4.16% error. Both analyses safety factors: 1.02 for the mathematical approach and 1.1 for the simulation, with a consistent 7.84% margin of error. The spring’s stiffness, calculated at 90.82 Nm/rad analytically and 85.71 Nm/rad in the simulation, exhibits a 5.62% difference. These results suggest significant potential for the proposed device in assisting patients with knee orthopedic restrictions, contributing to ongoing efforts in advancing the understanding and treatment of knee osteoarthritis.

Keywords: biomechanics, complaint mechanisms, gonarthrosis, orthoses

Procedia PDF Downloads 19
3914 Experimental Device to Test Corrosion Behavior of Materials in the Molten Salt Reactor Environment

Authors: Jana Petru, Marie Kudrnova

Abstract:

The use of technologies working with molten salts is conditioned by finding suitable construction materials that must meet several demanding criteria. In addition to temperature resistance, materials must also show corrosion resistance to salts; they must meet mechanical requirements and other requirements according to the area of use – for example, radiation resistance in Molten Salt Reactors. The present text describes an experimental device for studying the corrosion resistance of candidate materials in molten mixtures of salts and is a partial task of the international project ADAR, dealing with the evaluation of advanced nuclear reactors based on molten salts. The design of the device is based on a test exposure of Inconel 625 in the mixture of salts Hitec in a high temperature tube furnace. The result of the pre-exposure is, in addition to the metallographic evaluation of the behavior of material 625 in the mixture of nitrate salts, mainly a list of operational and construction problems that were essential for the construction of the new experimental equipment. The main output is a scheme of a newly designed gas-tight experimental apparatus capable of operating in an inert argon atmosphere, temperature up to 600 °C, pressure 3 bar, in the presence of a corrosive salt environment, with an exposure time of hundreds of hours. This device will enable the study of promising construction materials for nuclear energy.

Keywords: corrosion, experimental device, molten salt, steel

Procedia PDF Downloads 112
3913 Production of Size-Selected Tin Nanoclusters for Device Applications

Authors: Ahmad I. Ayesh

Abstract:

This work reports on the fabrication of tin nanoclusters by sputtering and inert-gas condensation inside an ultra-high vacuum compatible system. This technique allows to fine tune the size and yield of nanoclusters by controlling the nanocluster source parameters. The produced nanoclusters are deposited on SiO2/Si substrate with pre-formed electrical electrodes to produce a nanocluster device. Those devices can be potentially used for gas sensor applications.

Keywords: tin, nanoclusters, inert-gas condensation, nanotechnology

Procedia PDF Downloads 349
3912 The Trauma Suffered by Left behind Children and Its Impact on Their Emotional Development: A Pilot Study with Brazilian Immigrants in the United States

Authors: Liliane Clark

Abstract:

Immigrating to a different country may imply having to handle many difficult exertions. There is a particular issue that has to be endured by some immigrants: the children they had to leave behind. It is a phenomenon that occurs with certain frequency. Surprisingly, despite the fact that immigration in the United States is such a large proceeding, there is not much research about the topic in America exploring the trauma of the abandonment caused by this separation and its consequences on the mental health of those children. The term “left behind children” is usually applied to children who were left behind by their parents in their original nation under the care of a noteworthy relative, frequently the grandparents, when they moved to another country. This preliminary research, which is a partial study projected for a doctoral thesis, investigated whether the trauma of abandonment experienced by ten left behind children had affected their emotional development. The Strengths and Difficulties Questionnaire (SDQ) and a brief interview were utilized to assess the information. The SDQ explored scales such as emotional symptoms, conduct problems, hyperactivity, peer problems and prosocial behavior. In this pilot study, the results indicated that all these issues had some sort of significant correlation between them. During the interviews, the participants or their parents identified a range of symptoms: anxiety disorder, eating disorders, panic attacks, psychotic-like experiences, drug use and depression. Hence, it seems that there is a connection between the trauma of abandonment suffered due to the separation and the children’s consequent symptomatic behavior. Further studies are indeed necessary to validate the initial results of this investigation.

Keywords: abandonment, parent migration, psychological problems, trauma

Procedia PDF Downloads 172
3911 Improvement of an Arm and Shoulder Exoskeleton Using Gyro Sensor

Authors: D. Maneetham

Abstract:

The developed exoskeleton device has to control joints between shoulder and arm. Exoskeleton device can help patients with hemiplegia upper so that the patient can help themselves in their daily life. Exoskeleton device includes a robot arm wear that looks like the movement is similar to the normal arm. Exoskeleton arm is powered by the motor through the cable with a control system that developed to control the movement of the joint of a robot arm. The arm will include the shoulder, the elbow, and the wrist. The control system is used Arduino Mega 2560 controller and the operation of the DC motor through the relay module. The control system can be divided into two modes such as the manual control with the joystick mode and automatically control with the movement of the head by Gyro sensor. The controller is also designed to move between the shoulder and the arm movement from their original location. Results have shown that the controller gave the best performance and all movements can be controlled.

Keywords: exoskeleton arm, hemiplegia upper, shoulder and arm, stroke

Procedia PDF Downloads 346
3910 Misdiagnosed Mammary Analogue Secretory Carcinoma of the Salivary Gland: A Case Report with a Review of the Literature

Authors: Yaya Gao, Jifeng Liu, Yafeng Liu

Abstract:

Objectives: This study aimed to improve clinicians' understanding and diagnosis of the Mammary analogue secretory carcinoma of the salivary gland(MASC). Methods: The clinical features of a MASC patient who was admitted to WestChina Hospital of Sichuan University in July 2020 were reviewed and analyzed. A 49-year-old woman with left upper neck pain for three months was admitted to the hospital. She underwent adenoma resection of the left submandibular gland 14 years ago and mucoepidermoid carcinoma resection surgery five years ago. Three months before admission, the patient developed pain in the left mandibular angle after "fatigue" and gradually developed radiation pain in the left ear, which could be relieved after rest. A mass of 1cm could be touched at the mandibular, with tenderness, poor mobility, and hard texture. No swelling, heat, pain, rupture, or pus was found on the surrounding skin. Color doppler ultrasonography of the salivary gland indicated a weak echo mass of 23*14*17mm in the left parotid gland. Results: Surgical excision was completed. Immunohistochemistry of the tumor samples after operation showed that P63(a few,+), CK7(+), S100(+), DOG1(-), Ki67(MIB-1)(+,5%),pan-TRK(+), PAS(+) . ETV-6 gene translocation was detected in FISH in postoperative pathology, which indicated MASC. After this diagnosis, the patient sent the postoperative specimen of the second submandibular tumor to our hospital for consultation. The morphology of the two was similar. FISH detected ETV-6 gene translocation, so the second pathological diagnosis was revised to MASC. Conclusion: MASC of the salivary gland is a rare salivary gland tumor whose diagnosis depends on the result of the ETV6-NTRK3 fusion gene.

Keywords: mammary analogue secretory carcinoma, ETV6-NTRK3, salivary gland, misdiagnosed

Procedia PDF Downloads 56
3909 Cadaveric Study of Lung Anatomy: A Surgical Overview

Authors: Arthi Ganapathy, Rati Tandon, Saroj Kaler

Abstract:

Introduction: A thorough knowledge of variations in lung anatomy is of prime significance during surgical procedures like lobectomy, pneumonectomy, and segmentectomy of lungs. The arrangement of structures in the lung hilum act as a guide in performing such procedures. The normal pattern of arrangement of hilar structures in the right lung is eparterial bronchus, pulmonary artery, hyparterial bronchus and pulmonary veins from above downwards. In the left lung, it is pulmonary artery, principal bronchus and pulmonary vein from above downwards. The arrangement of hilar structures from anterior to posterior in both the lungs is pulmonary vein, pulmonary artery, and principal bronchus. The bronchial arteries are very small and usually the posterior most structures in the hilum of lungs. Aim: The present study aims at reporting the variations in hilar anatomy (arrangement and number) of lungs. Methodology: 75 adult formalin fixed cadaveric lungs from the department of Anatomy AIIMS New Delhi were observed for variations in the lobar anatomy. Arrangement of pulmonary hilar structures was meticulously observed, and any deviation in the pattern of presentation was recorded. Results: Among the 75 adult lung specimens observed 36 specimens were of right lung and the rest of left lung. Seven right lung specimens showed only 2 lobes with an oblique fissure dividing them and one left lung showed 3 lobes. The normal pattern of arrangement of hilar structures was seen in 22 right lungs and 23 left lungs. Rest of the lung specimens (14 right and 16 left) showed a varied pattern of arrangement of hilar structures. Some of them showed alterations in the sequence of arrangement of pulmonary artery, pulmonary veins, bronchus, and others in the number of these structures. Conclusion: Alterations in the pattern of arrangement of structures in the lung hilum are quite frequent. A compromise in knowledge of such variations will result in inadvertent complications like intraoperative bleeding during surgical procedures.

Keywords: fissures, hilum, lobes, pulmonary

Procedia PDF Downloads 211
3908 Evaluation and Fault Classification for Healthcare Robot during Sit-To-Stand Performance through Center of Pressure

Authors: Tianyi Wang, Hieyong Jeong, An Guo, Yuko Ohno

Abstract:

Healthcare robot for assisting sit-to-stand (STS) performance had aroused numerous research interests. To author’s best knowledge, knowledge about how evaluating healthcare robot is still unknown. Robot should be labeled as fault if users feel demanding during STS when they are assisted by robot. In this research, we aim to propose a method to evaluate sit-to-stand assist robot through center of pressure (CoP), then classify different STS performance. Experiments were executed five times with ten healthy subjects under four conditions: two self-performed STSs with chair heights of 62 cm and 43 cm, and two robot-assisted STSs with chair heights of 43 cm and robot end-effect speed of 2 s and 5 s. CoP was measured using a Wii Balance Board (WBB). Bayesian classification was utilized to classify STS performance. The results showed that faults occurred when decreased the chair height and slowed robot assist speed. Proposed method for fault classification showed high probability of classifying fault classes form others. It was concluded that faults for STS assist robot could be detected by inspecting center of pressure and be classified through proposed classification algorithm.

Keywords: center of pressure, fault classification, healthcare robot, sit-to-stand movement

Procedia PDF Downloads 188
3907 Net-Trainer-ST: A Swiss Army Knife for Pentesting, Based on Single Board Computer, for Cybersecurity Professionals and Hobbyists

Authors: K. Hołda, D. Śliwa, K. Daniec, A. Nawrat

Abstract:

This article was created as part of the developed master's thesis. It attempts to present a newly developed device, which will support the work of specialists dealing with broadly understood cybersecurity terms. The device is contrived to automate security tests. In addition, it simulates potential cyberattacks in the most realistic way possible, without causing permanent damage to the network, in order to maximize the quality of the subsequent corrections to the tested network systems. The proposed solution is a fully operational prototype created from commonly available electronic components and a single board computer. The focus of the following article is not only put on the hardware part of the device but also on the theoretical and applicatory way in which implemented cybersecurity tests operate and examples of their results.

Keywords: Raspberry Pi, ethernet, automated cybersecurity tests, ARP, DNS, backdoor, TCP, password sniffing

Procedia PDF Downloads 109
3906 Pragmatic Analysis of the Effectiveness of a Power Conditioning Device (DC-DC Converters) in a Simple Photovoltaics System

Authors: Asowata Osamede

Abstract:

Solar radiation provides the largest renewable energy potential on earth and photovoltaics (PV) are considered a promising technological solution to support the global transformation to a low-carbon economy and reduce dependence on fossil fuels. The aim of this paper is to evaluate the efficiency of power conditioning devices with a focus on the Buck and Boost DC-DC converters (12 V, 24 V and 48 V) in a basic off grid PV system with a varying load profile. This would assist in harnessing more of the available solar energy. The practical setup consists of a PV panel that is set to an orientation angle of 0º N, with corresponding tilt angles. Preliminary results, which include data analysis showing the power loss in the system and efficiency, indicate that the 12V DC-DC converter coupled with the load profile had the highest efficiency for a latitude of 26º S throughout the year.

Keywords: poly-crystalline PV panels, DC-DC converters, tilt and orientation angles, direct solar radiation, load profile

Procedia PDF Downloads 148
3905 Vortex Separator for More Accurate Air Dry-Bulb Temperature Measurement

Authors: Ahmed N. Shmroukh, I. M. S. Taha, A. M. Abdel-Ghany, M. Attalla

Abstract:

Fog systems application for cooling and humidification is still limited, although these systems require less initial cost compared with that of other cooling systems such as pad-and-fan systems. The undesirable relative humidity and air temperature inside the space which have been cooled or humidified are the main reasons for its limited use, which results from the poor control of fog systems. Any accurate control system essentially needs air dry bulb temperature as an input parameter. Therefore, the air dry-bulb temperature in the space needs to be measured accurately. The Scope of the present work is the separation of the fog droplets from the air in a fogged space to measure the air dry bulb temperature accurately. The separation is to be done in a small device inside which the sensor of the temperature measuring instrument is positioned. Vortex separator will be designed and used. Another reference device will be used for measuring the air temperature without separation. A comparative study will be performed to reach at the best device which leads to the most accurate measurement of air dry bulb temperature. The results showed that the proposed devices improved the measured air dry bulb temperature toward the correct direction over that of the free junction. Vortex device was the best. It respectively increased the temperature measured by the free junction in the range from around 2 to around 6°C for different fog on-off duration.

Keywords: fog systems, measuring air dry bulb temperature, temperature measurement, vortex separator

Procedia PDF Downloads 283
3904 Seismic Assessment of Passive Control Steel Structure with Modified Parameter of Oil Damper

Authors: Ahmad Naqi

Abstract:

Today, the passively controlled buildings are extensively becoming popular due to its excellent lateral load resistance circumstance. Typically, these buildings are enhanced with a damping device that has high market demand. Some manufacturer falsified the damping device parameter during the production to achieve the market demand. Therefore, this paper evaluates the seismic performance of buildings equipped with damping devices, which their parameter modified to simulate the falsified devices, intentionally. For this purpose, three benchmark buildings of 4-, 10-, and 20-story were selected from JSSI (Japan Society of Seismic Isolation) manual. The buildings are special moment resisting steel frame with oil damper in the longitudinal direction only. For each benchmark buildings, two types of structural elements are designed to resist the lateral load with and without damping devices (hereafter, known as Trimmed & Conventional Building). The target building was modeled using STERA-3D, a finite element based software coded for study purpose. Practicing the software one can develop either three-dimensional Model (3DM) or Lumped Mass model (LMM). Firstly, the seismic performance of 3DM and LMM models was evaluated and found excellent coincide for the target buildings. The simplified model of LMM used in this study to produce 66 cases for both of the buildings. Then, the device parameters were modified by ± 40% and ±20% to predict many possible conditions of falsification. It is verified that the building which is design to sustain the lateral load with support of damping device (Trimmed Building) are much more under threat as a result of device falsification than those building strengthen by damping device (Conventional Building).

Keywords: passive control system, oil damper, seismic assessment, lumped mass model

Procedia PDF Downloads 106
3903 Evaluation Using a Bidirectional Microphone as a Pressure Pulse Wave Meter

Authors: Shunsuke Fujiwara, Takashi Kaburagi, Kazuyuki Kobayashi, Kajiro Watanabe, Yosuke Kurihara

Abstract:

This paper describes a novel sensor device, a pressure pulse wave meter, which uses a bidirectional condenser microphone. The microphone work as a microphone as well as a sensor with high gain over a wide frequency range; they are also highly reliable and economical. Currently aging is becoming a serious social issue in Japan causing increased medical expenses in the country. Hence, it is important for elderly citizens to check health condition at home, and to care the health conditions through daily monitoring. Given this circumstances, we developed a novel pressure pulse wave meter based on a bidirectional condenser microphone. This novel pressure pulse wave meter device is used as a measuring instrument of health conditions.

Keywords: bidirectional microphone, pressure pulse wave meter, health condition, novel sensor device

Procedia PDF Downloads 538
3902 Design and Analysis of an Electro Thermally Symmetrical Actuated Microgripper

Authors: Sh. Foroughi, V. Karamzadeh, M. Packirisamy

Abstract:

This paper presents design and analysis of an electrothermally symmetrical actuated microgripper applicable for performing micro assembly or biological cell manipulation. Integration of micro-optics with microdevice leads to achieve extremely precise control over the operation of the device. Geometry, material, actuation, control, accuracy in measurement and temperature distribution are important factors which have to be taken into account for designing the efficient microgripper device. In this work, analyses of four different geometries are performed by means of COMSOL Multiphysics 5.2 with implementing Finite Element Methods. Then, temperature distribution along the fingertip, displacement of gripper site as well as optical efficiency vs. displacement and electrical potential are illustrated. Results show in addition to the industrial application of this device, the usage of that as a cell manipulator is possible.

Keywords: electro thermal actuator, MEMS, microgripper, MOEMS

Procedia PDF Downloads 152
3901 A Biomechanical Model for the Idiopathic Scoliosis Using the Antalgic-Trak Technology

Authors: Joao Fialho

Abstract:

The mathematical modelling of idiopathic scoliosis has been studied throughout the years. The models presented on those papers are based on the orthotic stabilization of the idiopathic scoliosis, which are based on a transversal force being applied to the human spine on a continuous form. When considering the ATT (Antalgic-Trak Technology) device, the existent models cannot be used, as the type of forces applied are no longer transversal nor applied in a continuous manner. In this device, vertical traction is applied. In this study we propose to model the idiopathic scoliosis, using the ATT (Antalgic-Trak Technology) device, and with the parameters obtained from the mathematical modeling, set up a case-by-case individualized therapy plan, for each patient.

Keywords: idiopathic scoliosis, mathematical modelling, human spine, Antalgic-Trak technology

Procedia PDF Downloads 256
3900 Femoropatellar Groove: An Anatomical Study

Authors: Mamatha Hosapatna, Anne D. Souza, Vrinda Hari Ankolekar, Antony Sylvan D. Souza

Abstract:

Introduction: The lower extremity of the femur is characterized by an anterior groove in which patella is held during motion. This groove separates the two lips of the trochlea (medial and lateral), prolongation of the two condyles. In humans, the lateral trochlear lip is more developed than the medial one, creating an asymmetric groove that is also specific to the human body. Because of femoral obliquity, contraction of quadriceps leads to a lateral dislocation stress on the patella, and the more elevated lateral side of the patellar groove helps the patella stays in its correct place, acting as a wall against lateral dislocation. This specific shape fits an oblique femur. It is known that femoral obliquity is not genetically determined but comes with orthostatism and biped walking. Material and Methodology: To measure the various dimensions of the Femoropatellar groove (FPG) and femoral condyle using digital image analyser. 37 dried adult femora (22 right,15 left) were used for the study. End on images of the lower end of the femur was taken. Various dimensions of the Femoropatellar groove and FP angle were measured using image J software. Results were analyzed statistically. Results: Maximum of the altitude of medial condyle of the right femur is 4.98± 0.35 cm and of the left femur is 5.20±.16 cm. Maximum altitude of lateral condyle is 5.44±0.4 and 5.50±0.14 on the right and left side respectively. Medial length of the groove is 1.30±0.38 cm on the right side and on the left side is 1.88±0.16 cm. The lateral length of the groove on the right side is 1.900±.16 cm and left side is 1.88±0.16 cm. Femoropatellar angle is 136.38◦±2.59 on the right side and on the left side it is 142.38◦±7.0 Angle and dimensions of the femoropatellar groove on the medial and lateral sides were measured. Asymmetry in the patellar groove was observed. The lateral lip was found to be wider and bigger which correlated with the previous studies. An asymmetrical patellar groove with a protruding lateral side associated with an oblique femur is a specific mark of bipedal locomotion. Conclusion: Dimensions of FPG are important in maintaining the stability of patella and also in knee replacement surgeries. The implants used in to replace the patellofemoral compartment consist of a metal groove to fit on the femoral end and a plastic disc that attaches to the undersurface of the patella. The location and configuration of the patellofemoral groove of the distal femur are clinically significant in the mechanics and pathomechanics of the patellofemoral articulation.

Keywords: femoral patellar groove, femoro patellar angle, lateral condyle, medial condyle

Procedia PDF Downloads 383
3899 3D Scaffolds Fabricated by Microfluidic Device for Rat Cardiomyocytes Observation

Authors: Chih-Wei Chao, Jiashing Yu

Abstract:

Microfluidic devices have recently emerged as promising tools for the fabrication of scaffolds for cell culture. To mimic the natural circumstances of organism for cells to grow, here we present three-dimensional (3D) scaffolds fabricated by microfluidics for cells cultivation. This work aims at investigating the behavior in terms of the viability and the proliferation capability of rat H9c2 cardiomyocytes in the gelatin 3D scaffolds by fluorescent images.

Keywords: microfluidic device, H9c2, tissue engineering, 3D scaffolds

Procedia PDF Downloads 409
3898 Sodium-glucose Co-transporter-2 Inhibitors in Heart Failure with Mildly Reduced Reduced Ejection Fraction: Future Perspectives in Patients with Neoplasia

Authors: M. A. Munteanu, A. M. Lungu, A. I. Chivescu, V. Teodorescu, E. Tufanoiu, C. Nicolae, T. I. Nanea

Abstract:

Introduction: Sodium-glucose co-transporter 2 inhibitors (SGLT2i), which were first developed as antidiabetic medications, have demonstrated numerous positive benefits on the cardiovascular system, especially in the prevention of heart failure (HF). HF is a challenging, multifaceted disease that needs all-encompassing therapy. It should not be viewed as a limited form of heart illness but rather as a systemic disease that leads to multiple organ failure and death. SGLT2i is an extremely effective tool for treating HF by using its pleiotropic effects. In addition to its use in patients with diabetes mellitus who are at high cardiovascular risk or who have already experienced a cardiovascular event, SGLT2i administration has been shown to have positive effects on a variety of HF manifestations and stages, regardless of the patient's presence of diabetes mellitus. Material and Methods: According to the guide, 110 patients (83 males and 27 females) with heart failure with mildly reduced ejection fraction (HFmrEF), with T2D and neoplasia, were enrolled in the prospective study. The structural and functional state of the left ventricle myocardium and ejection fraction was assessed through echocardiography. Patients were randomized to receive once-daily dapagliflozin 10 mg. Results: Patients with HFmrEF were divided into 3 subgroups according to age. 7% (8) patients aged < 45 years, 35% (28) patients aged between 46-59 years, and 58% (74) patients aged> 60 years. The most prevalent comorbidities were hypertension (43.1%), coronary heart disease (40%), and obesity (33.2%). Study drug discontinuation and serious adverse events were not frequent in the subgroups, in either men or women, until now. Conclusions: SGLT-2 inhibitors are a novel class of antidiabetic agents that have demonstrated positive efficacy and safety outcomes in the setting of HFmrEF. Until now, in our study, dapagliflozin was safe and well-tolerated irrespective of sex.

Keywords: diabetes mellitus type 2, Sodium-glucose co-transporters-2 inhibitors, heart failure, neoplasia

Procedia PDF Downloads 72
3897 Development of an Optimization Method for Myoelectric Signal Processing by Active Matrix Sensing in Robot Rehabilitation

Authors: Noriyoshi Yamauchi, Etsuo Horikawa, Takunori Tsuji

Abstract:

Training by exoskeleton robot is drawing attention as a rehabilitation method for body paralysis seen in many cases, and there are many forms that assist with the myoelectric signal generated by exercise commands from the brain. Rehabilitation requires more frequent training, but it is one of the reasons that the technology is required for the identification of the myoelectric potential derivation site and attachment of the device is preventing the spread of paralysis. In this research, we focus on improving the efficiency of gait training by exoskeleton type robots, improvement of myoelectric acquisition and analysis method using active matrix sensing method, and improvement of walking rehabilitation and walking by optimization of robot control.

Keywords: active matrix sensing, brain machine interface (BMI), the central pattern generator (CPG), myoelectric signal processing, robot rehabilitation

Procedia PDF Downloads 377
3896 Left Posterior Pericardiotomy in the Prevention of Post-Operative Atrial Fibrillation and Cardiac Tamponade: A Retrospective Study of 2118 Isolated Coronary Artery Bypass Graft Patients

Authors: Ayeshmanthe Rathnayake, Siew Goh, Carmel Fenton, Ashutosh Hardikar

Abstract:

Post-Operative Atrial Fibrillation (POAF) is the most frequent complication of cardiac surgery and is associated with reduced survival, increased rates of cognitive changes and cerebrovascular accident, heart failure, renal dysfunction, infection and length of stay, and hospital costs. Cardiac tamponade, although less common, carries high morbidity and mortality. Shed mediastinal blood in the pericardial space is a major source of intrapericardial oxidative stress and inflammation that triggers POAF. The utilisation of a left posterior pericardiotomy aims to shunt blood from the pericardium into the pleural space and have a role in the prevention of POAF as well as cardiac tamponade. 2118 patients had undergone isolated Coronary Artery Bypass Graft (CABG) at Royal Hobart Hospital from 2008-2021. They were divided into pericardiotomy vs control group. Patient baseline demographics, intraoperative data, and post-operative outcomes were reviewed retrospectively. Total incidence of new POAF and cardiac tamponade was 26.1% and 0.75%, respectively. Primary outcome of both the incidence of POAF(22.9% vs27.8%OR 0.77 p<0.05) and Cardiac Tamponade (0% vs 1.1% OR 0.85 p<0.05) were less in the pericardiotomy group.Increasing age, BMI, poor left ventricular function (EF <30%), and return to theatre were independent predictors of developing POAF. There were similar rates of return to theatre for bleeding however, no cases of tamponade in the pericardiotomy group. There were no complications attributable to left posterior pericardiotomy and the time added to the duration of surgery was minimal. Left posterior pericardiotomy is associated with a significant reduction in the incidence of POAFand cardiac tamponade and issafe and efficient.

Keywords: cardiac surgery, pericardiotomy, post-operative atrial fibrillation, cardiac tamponade

Procedia PDF Downloads 81
3895 Effects of Monofin Training on Left Ventricular Performance in Elite Egyptian Children Athletes

Authors: Magdy Abouzeid

Abstract:

Objectives: The aim of this study was to examine the influence of Monofin training, 36 weeks, 6 times per week, 90 min/unit on left ventricular performance in elite Egyptian Monofin athletes. Background: The elite athletes are one who has superior athletic talent. Monofin swimming already provide the most efficient way of swimming for human being, it is an aquatics sport practice on the surface or under water. Methods :To study these effects,14 elite Monofin children(3 girls and 11boys) aged(11.95± 1.09yr) HT (153.07± 4.2 cm) , WT(52.4 ± 3.7 kg ) , body surface area (BSA.m2 1.48 ± 5.6 m2 ) took part in long-term Monofin Training(LTMT).All subjects underwent two-dimension and M-mode Echordiography at rest before and after(LTMT). Results: There was significant difference (P < 0.01) and percentage improvement for all echocardiography parameter after (LTMT). Inter ventricular septal thickness in diastole and in systole increased by 27.9 % and 42.75 %. Left ventricular end systolic dimension and diastole increased by 16.81 % and 42.7 % respectively. Posterior wall thickness in systole was very highly increased by 283.3 % and in diastole increased by 51.78 %. Left ventricular mass in diastole and in systole increased by 44.8 % and 40.1 % respectively. Stroke volume and resting heart rate (HR) significant changed (sv) 25 %, (HR) 14.7 %. Conclusion: Monofin training is an effective sport to enhance ‘Heart athlete's’ for children, because the unique swim fin tool and create propulsion and overcome resistance. Further researches are needed to determine the effects of Monofin training on right ventricular in child athletes.

Keywords: prepubertal, monofin training, heart athlete's, elite child athlete, echocardiography

Procedia PDF Downloads 306