65 A Comparative Study on the Dimensional Error of 3D CAD Model and SLS RP Model for Reconstruction of Cranial Defect

Authors: L. Siva Rama Krishna, Sriram Venkatesh, M. Sastish Kumar, M. Uma Maheswara Chary

Abstract:

Rapid Prototyping (RP) is a technology that produces models and prototype parts from 3D CAD model data, CT/MRI scan data, and model data created from 3D object digitizing systems. There are several RP process like Stereolithography (SLA), Solid Ground Curing (SGC), Selective Laser Sintering (SLS), Fused Deposition Modelling (FDM), 3D Printing (3DP) among them SLS and FDM RP processes are used to fabricate pattern of custom cranial implant. RP technology is useful in engineering and biomedical application. This is helpful in engineering for product design, tooling and manufacture etc. RP biomedical applications are design and development of medical devices, instruments, prosthetics and implantation; it is also helpful in planning complex surgical operation. The traditional approach limits the full appreciation of various bony structure movements and therefore the custom implants produced are difficult to measure the anatomy of parts and analyse the changes in facial appearances accurately. Cranioplasty surgery is a surgical correction of a defect in cranial bone by implanting a metal or plastic replacement to restore the missing part. This paper aims to do a comparative study on the dimensional error of CAD and SLS RP Models for reconstruction of cranial defect by comparing the virtual CAD with the physical RP model of a cranial defect.

Keywords: rapid prototyping, selective laser sintering, cranial defect, dimensional error

Procedia PDF Downloads 309
64 Graphene Reinforced Magnesium Metal Matrix Composites for Biomedical Applications

Authors: Khurram Munir, Cuie Wen, Yuncang Li

Abstract:

Magnesium (Mg) metal matrix composites (MMCs) reinforced with graphene nanoplatelets (GNPs) have been developed by powder metallurgy (PM). In this study, GNPs with different concentrations (0.1-0.3 wt.%) were dispersed into Mg powders by high-energy ball-milling processes. The microstructure and resultant mechanical properties of the fabricated nanocomposites were characterized using transmission electron microscopy (TEM), scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDX), X-ray diffraction (XRD), Raman spectroscopy (RS), compression and nano-wear tests. The corrosion resistance of the fabricated composites was evaluated by electrochemical tests and hydrogen evolution measurements. Finally, the biological response of Mg-GNPs composites was assessed using osteoblast-like SaOS2 cells. The results indicate that GNPs are excellent candidates as reinforcements in Mg matrices for the manufacture of biodegradable Mg-based composite implants. GNP addition improved the mechanical properties of Mg via synergetic strengthening modes. Moreover, retaining the structural integrity of GNPs during PM processing improved the ductility, compressive strength, and corrosion resistance of the Mg-GNP composites as compared to monolithic Mg. Cytotoxicity assessments did not reveal any significant toxicity with the addition of GNPs to Mg matrices. This study demonstrates that Mg-xGNPs with x < 0.3 wt.%, may constitute novel biodegradable implant materials for load-bearing applications.

Keywords: magnesium-graphene composites, strengthening mechanisms, In vitro cytotoxicity, biocorrosion

Procedia PDF Downloads 138
63 Manufacturing and Characterization of Bioresorbable Self-Reinforced PLA Composites for Bone Applications

Authors: Carolina Pereira Lobato Costa, Cristina Pascual-González, Monica Echeverry, Javier LLorca, Carlos Gonzáléz, Juan Pedro Fernández-Bláquez

Abstract:

Although the potential of PLA self-reinforced composites for bone applications, not much literature addresses optimal manufacturing conditions. In this regard, this paper describes the woven self-reinforced PLA composites manufacturing processes: the commingling of yarns, weaving, and hot pressing and characterizes the manufactured laminates. Different structures and properties can be achieved by varying the hot compaction process parameters (pressure, holding time, and temperature). The specimens manufactured were characterized in terms of thermal properties (DSC), microstructure (C-scan optical microscope and SEM), strength (tensile test), and biocompatibility (MTT assays). Considering the final device, 155 ℃ for 10 min at 2 MPa act as the more appropriate hot pressing parameters. The laminate produced with these conditions has few voids/porosity, a tensile strength of 30.39 ± 1.21 MPa, and a modulus of 4.09 ± 0.24 GPa. Subsequently to the tensile testing was possible to observe fiber pullout from the fracture surfaces, confirming that this material behaves as a composite. From the results, no single laminate can fulfill all the requirements, being necessary to compromise in function of the priority property. Further investigation is required to improve materials' mechanical performance. Subsequently, process parameters and materials configuration can be adjusted depending on the place and type of implant to suit its function.

Keywords: woven fabric, self-reinforced polymer composite, poly(lactic acid), biodegradable

Procedia PDF Downloads 176
62 Triple Modulation on Wound Healing in Glaucoma Surgery Using Mitomycin C and Ologen Augmented with Anti-Vascular Endothelial Growth Factor

Authors: Reetika Sharma, Lalit Tejwani, Himanshu Shekhar, Arun Singhvi

Abstract:

Purpose: To describe a novel technique of trabeculectomy targeting triple modulation on wound healing to increase the overall success rate. Method: Ten eyes of 10 patients underwent trabeculectomy with subconjunctival mitomycin C (0.4mg/ml for 4 minutes) application combined with Ologen implantation subconjunctivally and subsclerally. Five of these patients underwent additional phacoemulsification with intraocular lens implantation. The Ologen implant was wet with 0.1 ml Bevacizumab. Result: All the eyes achieved target intraocular pressure (IOP), which was maintained until one year of follow-up. Two patients needed anterior chamber reformation at day two post surgery. One patient needed cataract surgery after four months of surgery and achieved target intraocular pressure on two topical antiglaucoma medicines. Conclusion: Vascular endothelial growth factor (VEGF) concentration has been seen to increase in the aqueous humor after filtration surgery. Ologen implantation helps in collagen remodelling, antifibroblastic response, and acts as a spacer. Bevacizumab augmented Ologen, in addition, targets the increased VEGF and helps in decreasing scarring. Anti-VEGF augmented Ologen in trabeculectomy with mitomycin C (MMC) hence appears to have encouraging short-term intraocular pressure control.

Keywords: ologen, anti-VEGF, trabeculectomy, scarring

Procedia PDF Downloads 167
61 Finite Element Analysis and Design Optimization of Stent and Balloon System

Authors: V. Hashim, P. N. Dileep

Abstract:

Stent implantation is being seen as the most successful method to treat coronary artery diseases. Different types of stents are available in the market these days and the success of a stent implantation greatly depends on the proper selection of a suitable stent for a patient. Computer numerical simulation is the cost effective way to choose the compatible stent. Studies confirm that the design characteristics of stent do have great importance with regards to the pressure it can sustain, the maximum displacement it can produce, the developed stress concentration and so on. In this paper different designs of stent were analyzed together with balloon to optimize the stent and balloon system. Commercially available stent Palmaz-Schatz has been selected for analysis. Abaqus software is used to simulate the system. This work is the finite element analysis of the artery stent implant to find out the design factors affecting the stress and strain. The work consists of two phases. In the first phase, stress distribution of three models were compared - stent without balloon, stent with balloon of equal length and stent with balloon of extra length than stent. In second phase, three different design models of Palmaz-Schatz stent were compared by keeping the balloon length constant. The results obtained from analysis shows that, the design of the strut have strong effect on the stress distribution. A design with chamfered slots found better results. The length of the balloon also has influence on stress concentration of the stent. Increase in length of the balloon will reduce stress, but will increase dog boning effect.

Keywords: coronary stent, finite element analysis, restenosis, stress concentration

Procedia PDF Downloads 608
60 Adherence of Trauma and Orthopaedics Surgery Operative Notes to the RCS Good Surgical Practice Guidelines in Ashford and St. Peter's Hospital

Authors: Maryam Risla Shahul Hameed, Tharsiga Yogarajah, Fritzy Mathew, Tayyaba Syed, Shalin Shaunak

Abstract:

Aim: Auditing the adherence of Trauma and Orthopaedics Operative notes to the RCS Good Surgical Practice Guidelines. Method: Clinical audit conducted on 150 operative notes over a period of 2 months April- May 2023, including emergency and elective surgeries performed in Ashford and St. Peter’s Hospital. The RCS Good Practice Surgical Guidelines for an ideal operative note were used to compare.Results: Date of the procedure and signature of the surgeon were mentioned in all the notes by default in the electronic template being used. Title of the operation performed and whether elective or emergency were mentioned by 92% and 45%, respectively. Name of theatre anaesthetist and operating surgeons were mentioned by 73% and 93% respectively. Time of surgery mentioned by 26%. Operative findings and operative diagnosis mentioned by 83% and 53% respectively. Incision and complications of surgery mentioned in 80% and 53%, respectively. Details of tissue added/ altered/ removed mentioned by 46%. Information on prosthesis or implant used is mentioned by 54%. Details of closure and anticipated blood loss mentioned in 91% and 45% respectively. Antibiotic prophylaxis was mentioned by 63%, out of which only 23% mentioned the name and duration of the antibiotic. VTE prophylaxis was mentioned by 84%, out of which only 23% and 29% mentioned the name and duration of the prophylaxis, respectively. Conclusion: There is more for improvement in the operative notes for better continuity of care between the operating surgeons and other doctors in the wards taking care of the patients post operatively. We recommend to follow a standardized guidelines by all the nationwide and a standard template to be followed by all.

Keywords: surgery, notes, RCS, guidelines

Procedia PDF Downloads 143
59 The Effect of Tool Path Strategy on Surface and Dimension in High Speed Milling

Authors: A. Razavykia, A. Esmaeilzadeh, S. Iranmanesh

Abstract:

Many orthopedic implants like proximal humerus cases require lower surface roughness and almost immediate/short lead time surgery. Thus, rapid response from the manufacturer is very crucial. Tool path strategy of milling process has a direct influence on the surface roughness and lead time of medical implant. High-speed milling as promised process would improve the machined surface quality, but conventional or super-abrasive grinding still required which imposes some drawbacks such as additional costs and time. Currently, many CAD/CAM software offers some different tool path strategies to milling free form surfaces. Nevertheless, the users must identify how to choose the strategies according to cutting tool geometry, geometry complexity, and their effects on the machined surface. This study investigates the effect of different tool path strategies for milling a proximal humerus head during finishing operation on stainless steel 316L. Experiments have been performed using MAHO MH700 S vertical milling machine and four machining strategies, namely, spiral outward, spiral inward, and radial as well as zig-zag. In all cases, the obtained surfaces were analyzed in terms of roughness and dimension accuracy compared with those obtained by simulation. The findings provide evidence that surface roughness, dimensional accuracy, and machining time have been affected by the considered tool path strategy.

Keywords: CAD/CAM software, milling, orthopedic implants, tool path strategy

Procedia PDF Downloads 195
58 Mechanical Properties of Powder Metallurgy Processed Biodegradable Zn-Based Alloy for Biomedical Application

Authors: Maruf Yinka Kolawole, Jacob Olayiwola Aweda, Farasat Iqbal, Asif Ali, Sulaiman Abdulkareem

Abstract:

Zinc is a non-ferrous metal with potential application in orthopaedic implant materials. However, its poor mechanical properties were major challenge to its application. Therefore, this paper studies the mechanical properties of biodegradable Zn-based alloy for biomedical application. Pure zinc powder with varying (0, 1, 2, 3 & 6) wt% of magnesium powders were ball milled using ball-to-powder ratio (B:P) of 10:1 at 350 rpm for 4 hours. The resulting milled powders were compacted and sintered at 300 MPa and 350 °C respectively. Microstructural, phase and mechanical properties analyses were performed following American standard of testing and measurement. The results show that magnesium has influence on the mechanical properties of zinc. The compressive strength, hardness and elastic modulus of 210 ± 8.878 MPa, 76 ± 5.707 HV and 45 ± 11.616 GPa respectively as obtained in Zn-2Mg alloy were optimum and meet the minimum requirement of biodegradable metal for orthopaedics application. These results indicate an increase of 111, 93 and 93% in compressive strength, hardness and elastic modulus respectively as compared to pure zinc. The increase in mechanical properties was adduced to effectiveness of compaction pressure and intermetallic phase formation within the matrix resulting in high dislocation density for improving strength. The study concluded that, Zn-2Mg alloy with optimum mechanical properties can therefore be considered a potential candidate for orthopaedic application.

Keywords: Biodegradable metal, Biomedical application, Mechanical properties, Powder Metallurgy, Zinc

Procedia PDF Downloads 120
57 Comparative Analysis of Hybrid Dynamic Stabilization and Fusion for Degenerative Disease of the Lumbosacral Spine: Finite Element Analysis

Authors: Mohamed Bendoukha, Mustapha Mosbah

Abstract:

The Radiographic apparent assumed that the asymptomatic adjacent segment disease ASD is common after lumbar fusion, but this does not correlate with the functional outcomes while compensatory increased motion and stresses at the adjacent level of fusion is well-known to be associated to ASD. Newly developed, the hybrid stabilization are allocated to substituted for mostly the superior level of the fusion in an attempt to reduce the number of fusion levels and likelihood of degeneration process at the adjacent levels during the fusion with pedicle screws. Nevertheless, its biomechanical efficiencies still remain unknown and complications associated with failure of constructs such screw loosening and toggling should be elucidated In the current study, a finite element (FE) study was performed using a validated L2/S1 model subjected to a moment of 7.5 Nm and follower load of 400 N to assess the biomedical behavior of hybrid constructs based on dynamic topping off, semi rigid fusion. The residual range of motion (ROM), stress distribution at the fused and adjacent levels, stress distribution at the disc and the cage-endplate interface with respect to changes of bone quality were investigated. The hybrid instrumentation was associated with a reduction in compressive stresses compared to the fusion construct in the adjacent-level disc and showed high substantial axial force in the implant while fusion instrumentation increased the motion for both flexion and extension.

Keywords: intervertebral disc, lumbar spine, degenerative nuclesion, L4-L5, range of motion finite element model, hyperelasticy

Procedia PDF Downloads 161
56 Stem Cell Fate Decision Depending on TiO2 Nanotubular Geometry

Authors: Jung Park, Anca Mazare, Klaus Von Der Mark, Patrik Schmuki

Abstract:

In clinical application of TiO2 implants on tooth and hip replacement, migration, adhesion and differentiation of neighboring mesenchymal stem cells onto implant surfaces are critical steps for successful bone regeneration. In a recent decade, accumulated attention has been paid on nanoscale electrochemical surface modifications on TiO2 layer for improving bone-TiO2 surface integration. We generated, on titanium surfaces, self-assembled layers of vertically oriented TiO2 nanotubes with defined diameters between 15 and 100 nm and here we show that mesenchymal stem cells finely sense TiO2 nanotubular geometry and quickly decide their cell fate either to differentiation into osteoblasts or to programmed cell death (apoptosis) on TiO2 nanotube layers. These cell fate decisions are critically dependent on nanotube size differences (15-100nm in diameters) of TiO2 nanotubes sensing by integrin clustering. We further demonstrate that nanoscale topography-sensing is feasible not only in mesenchymal stem cells but rather seems as generalized nanoscale microenvironment-cell interaction mechanism in several cell types composing bone tissue network including osteoblasts, osteoclast, endothelial cells and hematopoietic stem cells. Additionally we discuss the synergistic effect of simultaneous stimulation by nanotube-bound growth factor and nanoscale topographic cues on enhanced bone regeneration.

Keywords: TiO2 nanotube, stem cell fate decision, nano-scale microenvironment, bone regeneration

Procedia PDF Downloads 413
55 Self-Organized TiO₂–Nb₂O₅–ZrO₂ Nanotubes on β-Ti Alloy by Anodization

Authors: Muhammad Qadir, Yuncang Li, Cuie Wen

Abstract:

Surface properties such as topography and physicochemistry of metallic implants determine the cell behavior. The surface of titanium (Ti)-based implant can be modified to enhance the bioactivity and biocompatibility. In this study, a self-organized titania–niobium pentoxide–zirconia (TiO₂–Nb₂O₅–ZrO₂) nanotubular layer on β phase Ti35Zr28Nb alloy was fabricated via electrochemical anodization. Energy-dispersive X-ray spectroscopy (EDX), scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS) and water contact angle measurement techniques were used to investigate the nanotubes dimensions (i.e., the inner and outer diameters, and wall thicknesses), microstructural features and evolution of the hydrophilic properties. The in vitro biocompatibility of the TiO₂–Nb₂O₅–ZrO₂ nanotubes (NTs) was assessed by using osteoblast cells (SaOS2). Influence of anodization parameters on the morphology of TiO₂–Nb₂O₅–ZrO₂ NTs has been studied. The results indicated that the average inner diameter, outer diameter and the wall thickness of the TiO₂–Nb₂O₅–ZrO₂ NTs were ranged from 25–70 nm, 45–90 nm and 5–13 nm, respectively, and were directly influenced by the applied voltage during anodization. The average inner and outer diameters of NTs increased with increasing applied voltage, and the length of NTs increased with increasing anodization time and water content of the electrolyte. In addition, the size distribution of the NTs noticeably affected the hydrophilic properties and enhanced the biocompatibility as compared with the uncoated substrate. The results of this study could be considered for developing nano-scale coatings for a wide range of biomedical applications.

Keywords: Titanium alloy, TiO₂–Nb₂O₅–ZrO₂ nanotubes, anodization, surface wettability, biocompatibility

Procedia PDF Downloads 133
54 Common Causes of Eye Removal Surgery in Turkish Patients: A Review of 226 Cases

Authors: Titap Yazicioglu

Abstract:

Purpose: To determine the etiological factors responsible for the eye removal surgery and to evaluate our surgical results. Material and Methods: Medical records of 226 patients, who underwent eye removal surgery, were analyzed retrospectively. Demographic information, clinical history, surgical procedure, and histopathological data were all collected. Evisceration surgery was performed under general anesthesia in all patients except tumor cases and one patient with rhino-orbital mucormycosis. The patients were followed for an average of 16.46±10.78 months and checked for the possible complications, cosmesis, and functional results.Results: 144 men, and 82 women,with a mean age of 41.78±22.6 years, were underwent enucleation (n=15) or evisceration (n=211) due to traumatic (n=169) and non-traumatic (n=57) causes. In the traumatic group, 79.8% of 169 patients were injured by penetrating and 14.2% by blunt trauma.3.6% of the patients were injured in a traffic accident, and 2.4% of them were injured by explosives. In the non-traumatic group, 40% of 25 patients had post-traumatic endophthalmitis, 32% had endophthalmitis due to corneal ulceration and melting, and 24% had endophthalmitis after cataract surgery. One patient had panophthalmitis due to rhino-orbital mucormycosis. Another cause in the non-traumatic group was glaucoma, of which 92.3% had neovascular glaucoma, and 8.7% had congenital glaucoma. Of the 14 patients who were enucleated for tumor, 35.7% had retinoblastoma, 14.3% had medulloepithelioma, 42.9% had uveal melanoma, and 7.1% had metastatic tumor from paranasal sinuses.The most common complaint in the follow-up period was discharging, seen in all prosthesis-wearing patients. 13.3% of the patients had itching due to ocular prosthesis. 4.4% of the patients were complaining about deep superior sulcus. 4.4% had pyogenic granuloma, and 17.8% had implant exposure. Conclusion: Etiological factors should be carefully evaluated, and precautions should be taken in order to reduce the devastating effect of the physical loss of the eye.

Keywords: enucleation, evisceration, ocular injury, etiology, frequency

Procedia PDF Downloads 88
53 Thresholding Approach for Automatic Detection of Pseudomonas aeruginosa Biofilms from Fluorescence in situ Hybridization Images

Authors: Zonglin Yang, Tatsuya Akiyama, Kerry S. Williamson, Michael J. Franklin, Thiruvarangan Ramaraj

Abstract:

Pseudomonas aeruginosa is an opportunistic pathogen that forms surface-associated microbial communities (biofilms) on artificial implant devices and on human tissue. Biofilm infections are difficult to treat with antibiotics, in part, because the bacteria in biofilms are physiologically heterogeneous. One measure of biological heterogeneity in a population of cells is to quantify the cellular concentrations of ribosomes, which can be probed with fluorescently labeled nucleic acids. The fluorescent signal intensity following fluorescence in situ hybridization (FISH) analysis correlates to the cellular level of ribosomes. The goals here are to provide computationally and statistically robust approaches to automatically quantify cellular heterogeneity in biofilms from a large library of epifluorescent microscopy FISH images. In this work, the initial steps were developed toward these goals by developing an automated biofilm detection approach for use with FISH images. The approach allows rapid identification of biofilm regions from FISH images that are counterstained with fluorescent dyes. This methodology provides advances over other computational methods, allowing subtraction of spurious signals and non-biological fluorescent substrata. This method will be a robust and user-friendly approach which will enable users to semi-automatically detect biofilm boundaries and extract intensity values from fluorescent images for quantitative analysis of biofilm heterogeneity.

Keywords: image informatics, Pseudomonas aeruginosa, biofilm, FISH, computer vision, data visualization

Procedia PDF Downloads 115
52 Impact of Obesity on Outcomes in Breast Reconstruction: A Systematic Review and Meta-Analysis

Authors: Adriana C. Panayi, Riaz A. Agha, Brady A. Sieber, Dennis P. Orgill

Abstract:

Background: Increased rates of both breast cancer and obesity have resulted in more women seeking breast reconstruction. These women may be at increased risk for perioperative complications. A systematic review was conducted to assess the outcomes in obese women who have undergone breast reconstruction following mastectomy. Methods: Cochrane, PUBMED and EMBASE electronic databases were screened and data was extracted from included studies. The clinical outcomes assessed were surgical complications, medical complications, length of postoperative hospital stay, reoperation rate and patient satisfaction. Results: 33 studies met the inclusion criteria for the review and 29 provided enough data to be included in the meta-analysis (71368 patients, 20061 of which were obese). Obese women were 2.3 times more likely to experience surgical complications (95 percent CI 2.19 to 2.39; P < 0.00001), 2.8 times more likely to have medical complications (95 percent CI 2.41 to 3.26; P < 0.00001) and had a 1.9 times higher risk of reoperation (95 percent CI 1.75 to 2.07; P < 0.00001). The most common complication, wound dehiscence, was 2.5 times more likely in obese women (95 percent CI 1.80 to 3.52; P < 0.00001). Sensitivity analysis confirmed that obese women were more likely to experience surgical complications (RR 2.36, 95% CI 2.22–2.52; P < 0.00001). Conclusions: This study provides evidence that obesity increases the risk of complications in both implant and autologous reconstruction. Additional prospective and observational studies are needed to determine if weight reduction prior to reconstruction reduces the perioperative risks associated with obesity.

Keywords: autologous reconstruction, breast cancer, breast reconstruction, literature review, obesity, oncology, prosthetic reconstruction

Procedia PDF Downloads 284
51 Determination of the Pull-Out/ Holding Strength at the Taper-Trunnion Junction of Hip Implants

Authors: Obinna K. Ihesiulor, Krishna Shankar, Paul Smith, Alan Fien

Abstract:

Excessive fretting wear at the taper-trunnion junction (trunnionosis) apparently contributes to the high failure rates of hip implants. Implant wear and corrosion lead to the release of metal particulate debris and subsequent release of metal ions at the taper-trunnion surface. This results in a type of metal poisoning referred to as metallosis. The consequences of metal poisoning include; osteolysis (bone loss), osteoarthritis (pain), aseptic loosening of the prosthesis and revision surgery. Follow up after revision surgery, metal debris particles are commonly found in numerous locations. Background: A stable connection between the femoral ball head (taper) and stem (trunnion) is necessary to prevent relative motions and corrosion at the taper junction. Hence, the importance of component assembly cannot be over-emphasized. Therefore, the aim of this study is to determine the influence of head-stem junction assembly by press fitting and the subsequent disengagement/disassembly on the connection strength between the taper ball head and stem. Methods: CoCr femoral heads were assembled with High stainless hydrogen steel stem (trunnion) by Push-in i.e. press fit; and disengaged by Pull-out test. The strength and stability of the two connections were evaluated by measuring the head pull-out forces according to ISO 7206-10 standards. Findings: The head-stem junction strength linearly increases with assembly forces.

Keywords: wear, modular hip prosthesis, taper head-stem, force assembly and disassembly

Procedia PDF Downloads 381
50 Osteoarthritis (OA): A Total Knee Replacement Surgery

Authors: Loveneet Kaur

Abstract:

Introduction: Osteoarthritis (OA) is one of the leading causes of disability, and the knee is the most commonly affected joint in the body. The last resort for treatment of knee OA is Total Knee Replacement (TKR) surgery. Despite numerous advances in prosthetic design, patients do not reach normal function after surgery. Current surgical decisions are made on 2D radiographs and patient interviews. Aims: The aim of this study was to compare knee kinematics pre and post-TKR surgery using computer-animated images of patient-specific models under everyday conditions. Methods: 7 subjects were recruited for the study. Subjects underwent 3D gait analysis during 4 everyday activities and medical imaging of the knee joint pre- and one-month post-surgery. A 3D model was created from each of the scans, and the kinematic gait analysis data was used to animate the images. Results: Improvements were seen in a range of motion in all 4 activities 1-year post-surgery. The preoperative 3D images provide detailed information on the anatomy of the osteoarthritic knee. The postoperative images demonstrate potential future problems associated with the implant. Although not accurate enough to be of clinical use, the animated data can provide valuable insight into what conditions cause damage to both the osteoarthritic and prosthetic knee joints. As the animated data does not require specialist training to view, the images can be utilized across the fields of health professionals and manufacturing in the assessment and treatment of patients pre and post-knee replacement surgery. Future improvements in the collection and processing of data may yield clinically useful data. Conclusion: Although not yet of clinical use, the potential application of 3D animations of the knee joint pre and post-surgery is widespread.

Keywords: Orthoporosis, Ortharthritis, knee replacement, TKR

Procedia PDF Downloads 22
49 3D Medical Printing the Key Component in Future of Medical Applications

Authors: Zahra Asgharpour, Eric Renteria, Sebastian De Boodt

Abstract:

There is a growing trend towards personalization of medical care, as evidenced by the emphasis on outcomes based medicine, the latest developments in CT and MR imaging and personalized treatment in a variety of surgical disciplines. 3D Printing has been introduced and applied in the medical field since 2000. The first applications were in the field of dental implants and custom prosthetics. According to recent publications, 3D printing in the medical field has been used in a wide range of applications which can be organized into several categories including implants, prosthetics, anatomical models and tissue bioprinting. Some of these categories are still in their infancy stage of the concept of proof while others are in application phase such as the design and manufacturing of customized implants and prosthesis. The approach of 3D printing in this category has been successfully used in the health care sector to make both standard and complex implants within a reasonable amount of time. In this study, some of the clinical applications of 3D printing in design and manufacturing of a patient-specific hip implant would be explained. In cases where patients have complex bone geometries or are undergoing a complex revision on hip replacement, the traditional surgical methods are not efficient, and hence these patients require patient-specific approaches. There are major advantages in using this new technology for medical applications, however, in order to get this technology widely accepted in medical device industry, there is a need for gaining more acceptance from the medical device regulatory offices. This is a challenge that is moving onward and will help the technology find its way at the end as an accepted manufacturing method for medical device industry in an international scale. The discussion will conclude with some examples describing the future directions of 3D Medical Printing.

Keywords: CT/MRI, image processing, 3D printing, medical devices, patient specific implants

Procedia PDF Downloads 279
48 Hip Resurfacing Makes for Easier Surgery with Better Functional Outcomes at Time of Revision: A Case Controlled Study

Authors: O. O. Onafowokan, K. Anderson, M. R. Norton, R. G. Middleton

Abstract:

Revision total hip arthroplasty (THA) is known to be a challenging procedure with potential for poor outcomes. Due to its lack of metaphyseal encroachment, hip resurfacing arthroplasty (HRA) is classified as a bone conserving procedure. Although the literature postulates that this is an advantage at time of revision surgery, there is no evidence to either support or refute this claim. We identified 129 hips that had undergone HRA and 129 controls undergoing first revision THA. We recorded the clinical assessment and survivorship of implants in a multi-surgeon, single centre, retrospective case control series for both arms. These were matched for age and sex. Data collected included demographics, indications for surgery, Oxford Hip Score (OHS), length of surgery, length of hospital stay, blood transfusion, implant complexity and further surgical procedures. Significance was taken as p < 0.05. Mean follow up was 7.5 years (1 to 15). There was a significant 6 point difference in postoperative OHS in favour of the revision resurfacing group (p=0.0001). The revision HRA group recorded 48 minutes less length of surgery (p<0.0001), 2 days less in length of hospital stay (p=0.018), a reduced need for blood transfusion (p=0.0001), a need for less complexity in revision implants (p=0.001) and a reduced probability of further surgery being required (P=0.003). Whilst we acknowledge the limitations of this study our results suggest that, in contrast to THA, the bone conservation element of HRA may make for a less traumatic revision procedure with better functional outcomes. Use of HRA has seen a dramatic decline as a result of concerns regarding metallosis. However, this information remains of relevance when counselling young active patients about their arthroplasty options and may become pertinent in the future if the promise of ceramic hip resurfacing is ever realized.

Keywords: hip resurfacing, metallosis, revision surgery, total hip arthroplasty

Procedia PDF Downloads 65
47 Influence of Loudness Compression on Hearing with Bone Anchored Hearing Implants

Authors: Anja Kurz, Marc Flynn, Tobias Good, Marco Caversaccio, Martin Kompis

Abstract:

Bone Anchored Hearing Implants (BAHI) are routinely used in patients with conductive or mixed hearing loss, e.g. if conventional air conduction hearing aids cannot be used. New sound processors and new fitting software now allow the adjustment of parameters such as loudness compression ratios or maximum power output separately. Today it is unclear, how the choice of these parameters influences aided speech understanding in BAHI users. In this prospective experimental study, the effect of varying the compression ratio and lowering the maximum power output in a BAHI were investigated. Twelve experienced adult subjects with a mixed hearing loss participated in this study. Four different compression ratios (1.0; 1.3; 1.6; 2.0) were tested along with two different maximum power output settings, resulting in a total of eight different programs. Each participant tested each program during two weeks. A blinded Latin square design was used to minimize bias. For each of the eight programs, speech understanding in quiet and in noise was assessed. For speech in quiet, the Freiburg number test and the Freiburg monosyllabic word test at 50, 65, and 80 dB SPL were used. For speech in noise, the Oldenburg sentence test was administered. Speech understanding in quiet and in noise was improved significantly in the aided condition in any program, when compared to the unaided condition. However, no significant differences were found between any of the eight programs. In contrast, on a subjective level there was a significant preference for medium compression ratios of 1.3 to 1.6 and higher maximum power output.

Keywords: Bone Anchored Hearing Implant, baha, compression, maximum power output, speech understanding

Procedia PDF Downloads 365
46 Efficacy of Collagen Matrix Implants in Phacotrabeculectomy with Mitomycin C at One Year

Authors: Lalit Tejwani, Reetika Sharma, Arun Singhvi, Himanshu Shekhar

Abstract:

Purpose: To assess the efficacy of collagen matrix implant (Ologen) in phacotrabeculectomy augmented with mitomycin C (MMC). Methods: A biodegradable collagen matrix (Ologen) was placed in the subconjunctival and subscleral space in twenty-two eyes of 22 patients with glaucoma and cataract who underwent combined phacoemulsification and trabeculectomy augmented with MMC. All of them were examined preoperatively and on the first postoperative day. They were followed for twelve months after surgery. Any intervention needed in follow-up period was noted. Any complication was recorded. The primary outcome measure was postoperative intraocular pressure at one year follow-up. Any additional postoperative treatments needed and adverse events were noted. Results: The mean age of patients included in the study was 57.77 ± 9.68 years (range=36 to 70 years). All the patients were followed for at least one year. Three patients had history of failed trabeculectomy. Fifteen patients had chronic angle closure glaucoma with cataract, five had primary open angle glaucoma with cataract, one had uveitic glaucoma with cataract, and one had juvenile open angle glaucoma with cataract. Mean preoperative IOP was 32.63 ± 8.29 mm Hg, eighteen patients were on oral antiglaucoma medicines. The mean postoperative IOP was 10.09 ± 2.65 mm Hg at three months, 10.36 ± 2.19 mm Hg at six months and 11.36 ± 2.72 mm Hg at one year follow up. No adverse effect related to Ologen was seen. Anterior chamber reformation was done in five patients, and three needed needling of bleb. Four patients needed additional antiglaucoma medications in the follow-up period. Conclusions: Combined phacotrabeculectomy with MMC with Ologen implantation appears to be a safe and effective option in glaucoma patients needing trabeculectomy with significant cataract. Comparative studies with longer duration of follow-up in larger number of patients are needed.

Keywords: combined surgery, ologen, phacotrabeculectomy, success

Procedia PDF Downloads 182
45 Tooth Fractures Following the Placement of Adjacent Dental Implants: A Case Series and a Systematic Review of the Literature

Authors: Eyal Rosen

Abstract:

This study is aimed to report a possible effect of the presence of dental implants on the development of crown or root fractures in adjacent natural teeth. A series of 26 cases of teeth diagnosed with crown or root fractures following the placement of adjacent dental implants is presented. In addition, a comprehensive systematic review of the literature was performed to detect other studies that evaluated this possible complication. The case series analysis revealed that all crown-fractured teeth were non-endodontically treated teeth (n=18), and all root fractured teeth were endodontically treated teeth (n=8). The time from implant loading to the diagnosis of a fracture in an adjacent tooth was longer than 1 year in 78% of cases. The majority of crown or root fractures occurred in female patients, over 50 years of age, with an average age of 59 in the crown fractures group, and 54 in the root fractures group. Most of the patients received 2 or more implants. Nine (50%) of the teeth with crown fracture were molars, 7 (39%) were mandibular premolars, and 2 (11%) were incisor teeth. The majority of teeth with root fracture were premolar or mandibular molar teeth (6 (75%)). The systematic review of the literature did not reveal additional studies that reported on this possible complication. To the best of the author’s knowledge this case series, although limited in its extent, is the first clinical report of a possible serious complication of implants, associated fractures in adjacent endodontically and non-endodontically treated natural teeth. The most common patient profile found in this series was a woman over 50 years of age, having a fractured premolar tooth, which was diagnosed more than 1 year after reconstruction that was based on multiple adjacent implants. Additional clinical studies are required in order to shed light on this potential serious complication.

Keywords: complications, dental implants, endodontics, fractured teeth

Procedia PDF Downloads 118
44 Acute Cartilage Defects of the Knee Treated With Chondral Restoration Procedures and Patellofemoral Stabilisation

Authors: John Scanlon, Antony Raymond, Randeep Aujla, Peter D’Alessandro, Satyen Gohil

Abstract:

Background: The incidence of significant acute chondral injuries with patella dislocation is around 10-15%. It is accepted that chondral procedures should only be performed in the presence of joint stability Methods:Patients were identified from surgeon/hospital logs. Patient demographics, lesion size and location, surgical procedure, patient reported outcome measures, post-operative MR imaging, and complications were recorded. PROMs and patient satisfaction was obtained. Results:20 knees (18 patients) were included. Mean age was 18.6 years (range; 11-39), and the mean follow-up was 16.6 months (range; 2-70). The defect locations were the lateral femoral condyle (9/20; 45%), patella (9/20; 45%), medial femoral condyle (1/20; 5%) and the trochlea (1/20; 5%). The mean defect size was 2.6cm2. Twelve knees were treated with cartilage fixation, 5 with microfracture, and 3 with OATS. At follow up, the overall mean Lysholm score was 77.4 (± 17.1), with no chondral regenerative procedure being statistically superior. There was no difference in Lysholm scores between those patients having acute medial patellofemoral ligament reconstruction versus medial soft tissue plication (p=0.59). Five (25%) knees required re-operation (one arthroscopic arthrolysis; one patella chondroplasty; two removal of loose bodies; one implant adjustment). Overall, 90% responded as being satisfied with surgery. Conclusion: Our aggressive pathway to identify and treat acute cartilage defects with early operative intervention and patella stabilisation has shown high rates of satisfaction and Lysholm scores. The full range of chondral restoration options should be considered by surgeons managing these patients.

Keywords: patella dislocation, chondral restoration, knee, patella stabilisation

Procedia PDF Downloads 106
43 Dosimetric Comparison of Conventional Optimization Methods with Inverse Planning Simulated Annealing Technique

Authors: Shraddha Srivastava, N. K. Painuly, S. P. Mishra, Navin Singh, Muhsin Punchankandy, Kirti Srivastava, M. L. B. Bhatt

Abstract:

Various optimization methods used in interstitial brachytherapy are based on dwell positions and dwell weights alteration to produce dose distribution based on the implant geometry. Since these optimization schemes are not anatomy based, they could lead to deviations from the desired plan. This study was henceforth carried out to compare anatomy-based Inverse Planning Simulated Annealing (IPSA) optimization technique with graphical and geometrical optimization methods in interstitial high dose rate brachytherapy planning of cervical carcinoma. Six patients with 12 CT data sets of MUPIT implants in HDR brachytherapy of cervical cancer were prospectively studied. HR-CTV and organs at risk (OARs) were contoured in Oncentra treatment planning system (TPS) using GYN GEC-ESTRO guidelines on cervical carcinoma. Three sets of plans were generated for each fraction using IPSA, graphical optimization (GrOPT) and geometrical optimization (GOPT) methods. All patients were treated to a dose of 20 Gy in 2 fractions. The main objective was to cover at least 95% of HR-CTV with 100% of the prescribed dose (V100 ≥ 95% of HR-CTV). IPSA, GrOPT, and GOPT based plans were compared in terms of target coverage, OAR doses, homogeneity index (HI) and conformity index (COIN) using dose-volume histogram (DVH). Target volume coverage (mean V100) was found to be 93.980.87%, 91.341.02% and 85.052.84% for IPSA, GrOPT and GOPT plans respectively. Mean D90 (minimum dose received by 90% of HR-CTV) values for IPSA, GrOPT and GOPT plans were 10.19 ± 1.07 Gy, 10.17 ± 0.12 Gy and 7.99 ± 1.0 Gy respectively, while D100 (minimum dose received by 100% volume of HR-CTV) for IPSA, GrOPT and GOPT plans was 6.55 ± 0.85 Gy, 6.55 ± 0.65 Gy, 4.73 ± 0.14 Gy respectively. IPSA plans resulted in lower doses to the bladder (D₂

Keywords: cervical cancer, HDR brachytherapy, IPSA, MUPIT

Procedia PDF Downloads 162
42 Finite Element Modelling for the Development of a Planar Ultrasonic Dental Scaler for Prophylactic and Periodontal Care

Authors: Martin Hofmann, Diego Stutzer, Thomas Niederhauser, Juergen Burger

Abstract:

Dental biofilm is the main etiologic factor for caries, periodontal and peri-implant infections. In addition to the risk of tooth loss, periodontitis is also associated with an increased risk of systemic diseases such as atherosclerotic cardiovascular disease and diabetes. For this reason, dental hygienists use ultrasonic scalers for prophylactic and periodontal care of the teeth. However, the current instruments are limited to their dimensions and operating frequencies. The innovative design of a planar ultrasonic transducer introduces a new type of dental scalers. The flat titanium-based design allows the mass to be significantly reduced compared to a conventional screw-mounted Langevin transducer, resulting in a more efficient and controllable scaler. For the development of the novel device, multi-physics finite element analysis was used to simulate and optimise various design concepts. This process was supported by prototyping and electromechanical characterisation. The feasibility and potential of a planar ultrasonic transducer have already been confirmed by our current prototypes, which achieve higher performance compared to commercial devices. Operating at the desired resonance frequency of 28 kHz with a driving voltage of 40 Vrms results in an in-plane tip oscillation with a displacement amplitude of up to 75 μm by having less than 8 % out-of-plane movement and an energy transformation factor of 1.07 μm/mA. In a further step, we will adapt the design to two additional resonance frequencies (20 and 40 kHz) to obtain information about the most suitable mode of operation. In addition to the already integrated characterization methods, we will evaluate the clinical efficiency of the different devices in an in vitro setup with an artificial biofilm pocket model.

Keywords: ultrasonic instrumentation, ultrasonic scaling, piezoelectric transducer, finite element simulation, dental biofilm, dental calculus

Procedia PDF Downloads 95
41 The Renewal of Chinese Urban Village on Cultural Ecology: Hubei Village as an Example

Authors: Shaojun Zheng, Lei Xu, Yunzi Wang

Abstract:

The main purpose of the research is to use the cultural ecology to analyze the renewal of Shenzhen urban village in the process of China's urbanization and to evaluate and guide the renewal, which will combine the society value and economic efficiency and activate urban villages. The urban village has a long history. There are also many old buildings, various residents, and a strong connection with the surrounding environment. Cultural ecology, which uses the knowledge of ecology to study culture, provides us a cultural perspective in the renewal. We take Hubei village in Shenzhen as our example. By using cultural ecology, we find a new way dealing with the relationship between culture and other factors. It helps us to give the buildings and space the culture meanings from different scales. It enables us to find a unique development pattern of urban village. After analyzing several famous cultural blocks cases, we find it is possible to connect the unique culture of urban village with the renovation of its buildings, community, and commerce. We propose the following strategies with specific target: 1. Building renovation: We repair and rebuild the origin buildings as little as possible, and retain the original urban space tissue as much as possible to keep the original sense of place and the cultural atmosphere. 2. Community upgrade: We reshape the village stream, fix the original function, add event which will activate people to complete the existing cultural circle 3. District commerce: We implant food and drink district, boutique commercial, and creative industries, to make full use of the historical atmosphere of the site to enhance the culture feelings For the renewal of a seemingly chaotic mixed urban village, it is important to break out from the conventional practices of building shopping malls or residential towers. Without creating those building landmarks, cultural ecology activates the urban village by exploiting its unique culture, which makes the old and new combine and becomes a new stream of energy, forming the new cultural, commercial and stylish landmark of the city.

Keywords: cultural ecology, urban village, renewal, combination

Procedia PDF Downloads 348
40 Auditory Function in Hypothyroidism as Compared to Controls

Authors: Mrunal Phatak

Abstract:

Introduction: Thyroid hormone is important for the normal function of the auditory system. Hearing impairment can occur insidiously in subclinical hypothyroidism. The present study was undertaken with the aim of evaluating audiological tests like tuning fork tests, pure tone audiometry, brainstem evoked auditory potentials (BAEPs), and auditory reaction time (ART) in hypothyroid women and in age and sex-matched controls to evaluate the effect of thyroid hormone on hearing. The objective of the study was to investigate hearing status by the audiological profile in hypothyroidism (group 1) and healthy controls (group 2) to compare the audiological profile between these groups and find the correlation of levels of TSH, T3 and T4 with the above parameters. Material and methods: A total sample size of 124 women in the age group of 30 to 50 years was recruited and divided into the Cases group comprising 62 newly diagnosed hypothyroid women and a Control group having 62 women with normal thyroid profiles. Otoscopic examination, tuning fork tests, Pure tone audiometry tests (PTA). Brain Stem Auditory Evoked Potential (BAEP) and Auditory Reaction Time (ART) were done in both ears, i.e., a total of 248 ears of all subjects. Results: By BAEPs, hearing impairment was detected in a total of 64 years (51.61%). A significant increase was seen in Wave V latency, IPL I-V and IPL III-V, and the decrease was seen in the amplitude of Wave I and V in both the ears cases. A positive correlation of Wave V latency of the Right and Left ears is seen with TSH levels (p < 0.001) and a negative correlation with T3 (>0.05) and with T4 (p < 0.01). The negative correlation of wave V amplitude of the Right and Left ears is seen with TSH levels (p < 0.001), and a significant positive correlation is seen with T3 and T4. Pure tone audiometry parameters showed hearing impairment of conductive (31.29%), sensorineural (36.29%), as well as mixed type (15.32%). Hearing loss was mild in 65.32% of ears and moderate in 17.74% of ears. Pure tone averages (PTA) were significantly increased in cases than in controls in both ears. A significant positive correlation of PTA of Right and Left ears is seen with TSH levels (p<0.05). A negative correlation between T3 and T4 is seen. A significant increase in HF ART and LF ART is seen in cases as compared to controls. A positive correlation between ART of high frequency and low frequency is seen with TSH levels and a negative correlation with T3 and T4 (p > 0.05). Conclusion: The abnormal BAEPs in hypothyroid women suggest an impaired central auditory pathway. BAEP abnormalities are indicative of a nonspecific injury in the bulbo-ponto-mesencephalic centers. The results of auditory investigations suggest a causal relationship between hypothyroidism and hearing loss. The site of lesion in the auditory pathway is probably at several levels, namely, in the middle ear and at cochlear and retrocochlear sites. Prolonged ART also suggests an impairment in central processing mechanisms. The results of the present study conclude that the probable reason for hearing impairment in hypothyroidism may be delayed impulse conduction in the acoustic nerve up to the level of the midbrain (IPL I-V, III-V), particularly the inferior colliculus (wave V). There is also impairment in central processing mechanisms, as shown by prolonged ART.

Keywords: hypothyroidism, deafness, pure tone audiometry, brain stem auditory evoked potential

Procedia PDF Downloads 13
39 Auditory Profile Function in Hypothyroidism

Authors: Mrunal Phatak, Suvarna Raut

Abstract:

Introduction: Thyroid hormone is important for the normal function of the auditory system. Hearing impairment can occur insidiously in subclinical hypothyroidism. The present study was undertaken with the aims of evaluating audiological tests like tuning fork tests, pure tone audiometry, brainstem evoked auditory potentials (BAEPs), and auditory reaction time (ART) in hypothyroid women and in age and sex matched controls so as to evaluate the effect of thyroid hormone on hearing. The objective of the study was to investigate hearing status by the audiological profile in hypothyroidism (group 1) and healthy controls ( group 2) to compare the audiological profile between these groups and find the correlation of levels of TSH, T3, and T4 with the above parameters. Material and methods: A total sample size of 124 women in the age group of 30 to 50 years was recruited and divided into the Cases group comprising of 62 newly diagnosed hypothyroid women and the Control group having 62 women with normal thyroid profile. Otoscopic examination, tuning fork tests, Pure tone audiometry tests (PTA). Brain Stem Auditory Evoked Potential (BAEP) and Auditory Reaction Time (ART) were done in both ears, i.e. total 248 ears of all subjects. Results: By BAEPs, hearing impairment was detected in total 64 ears (51.61%). A significant increase was seen in Wave V latency, IPL I-V, and IPL III-V, and the decrease was seen in the amplitude of Wave I and V in both the ears in cases. Positive correlation of Wave V latency of Right and Left ears is seen with TSH levels (p < 0.001) and a negative correlation with T3 (>0.05) and with T4 (p < 0.01). Negative correlation of wave V amplitude of Right and Left ears is seen with TSH levels (p < 0.001), and a significant positive correlation is seen with T3 and T4. Pure tone audiometry parameters showed hearing impairment of conductive (31.29%), sensorineural (36.29%), as well as the mixed type (15.32%). Hearing loss was mild in 65.32% of ears and moderate in 17.74% of ears. Pure tone averages (PTA) were significantly increased in cases than in controls in both the ears. Significant positive correlation of PTA of Right and Left ears is seen with TSH levels (p<0.05). Negative correlation with T3 and T4 is seen. A significant increase in HF ART and LF ART is seen in cases as compared to controls. Positive correlation of ART of high frequency and low frequency is seen with TSH levels and a negative correlation with T3 and T4 (p > 0.05). Conclusion: The abnormal BAEPs in hypothyroid women suggest an impaired central auditory pathway. BAEP abnormalities are indicative of a nonspecific injury in the bulbo-ponto-mesencephalic centres. The results of auditory investigations suggest a causal relationship between hypothyroidism and hearing loss. The site of lesion in the auditory pathway is probably at several levels, namely, in the middle ear and at cochlear and retrocochlear sites. Prolonged ART also suggests the impairment in central processing mechanisms. The results of the present study conclude that the probable reason for hearing impairment in hypothyroidism may be delayed impulse conduction in acoustic nerve up to the level of the midbrain (IPL I-V, III-V), particularly inferior colliculus (wave V). There is also impairment in central processing mechanisms, as shown by prolonged ART.

Keywords: deafness, pure tone audiometry, brain stem auditory evoked potential, hyopothyroidism

Procedia PDF Downloads 107
38 Identification of Genes Regulating Differentiation and Stemness of Human Mesenchymal Stem Cells for Gene Therapy in Regenerative Medicine

Authors: Tong Ming Liu

Abstract:

Human mesenchymal stem cells (MSCs) represent the most used stem cells for clinical application, which have been used in over 1000 clinical trials to treat over 30 diseases due to multilineage differentiation potential, secretome and immunosuppression. Gene therapies of MSCs hold great promise in the treatment of many diseases due to enhanced MSC-based clinical outcomes. To identify genes for gene therapy of MSCs, by comparing gene expression profile before and after MSC differentiation following by functional screening, we have identified ZNF145 that regulated MSC differentiation. Forced expression of ZNF145 resulted in enhanced in vitro chondrogenesis of MSCs as an upstream factor of SOX9 and improved osteochondral repair upon implant into osteochondral defects in rodents. By comparing gene expression profile during differentiation of iPSCs toward MSCs, we also identified gene HOX regulating MSC stemness, which was much downregulated in late-passaged MSCs. Knockdown of this gene greatly compromised MSC stemness including abolished proliferation, decreased CFU-F, promoted senescence and reduced expression of cell surface antigens linked to the MSC phenotype. In addition, multi-linage differentiation was also greatly impaired. Notably, HOX overexpression resulted in improved multi-lineage differentiation. In the mechanism, HOX expression significantly deceased in late passage of MSCs compared with early passage of MSCs, correlating with MSC important genes. ChIP-seq data shown that HOX binds to genes related to MSC self-renewal and differentiation. Most importantly, most HOX binding sites are lost in late passage of MSCs. HOX exerts its effects by directing binding Twist1, one important gene of MSCs. The identification of the genes regulating MSC differentiation and stemness will provide and promising strategies for gene therapy of MSCs in regenerative medicine.

Keywords: mesenchymal stem cell, novel transcription factor, stemness, gene therapy, cartilage repair, signaling pathway

Procedia PDF Downloads 32
37 Modification of Titanium Surfaces with Micro/Nanospheres for Local Antibiotic Release

Authors: Burcu Doymus, Fatma N. Kok, Sakip Onder

Abstract:

Titanium and titanium-based materials are commonly used to replace or regenerate the injured or lost tissues because of accidents or illnesses. Hospital infections and strong bond formation at the implant-tissue interface are directly affecting the success of the implantation as weak bonding with the native tissue and hospital infections lead to revision surgery. The purpose of the presented study is to modify the surface of the titanium substrates with nano/microspheres for local drug delivery and to prevent hospital infections. Firstly, titanium surfaces were silanized with APTES (3-Triethoxysilylpropylamine) following the negatively charged oxide layer formation. Then characterization studies using Scanning Electron Microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR) were done on the modified surfaces. Secondly, microspheres/nanospheres were prepared with chitosan that is a natural polymer and having valuable properties such as non-toxicity, high biocompatibility, low allergen city and biodegradability for biomedical applications. Antibiotic (ciprofloxacin) loaded micro/nanospheres have been fabricated using emulsion cross-linking method and have been immobilized onto the titanium surfaces with different immobilization techniques such as covalent bond and entrapment. Optimization studies on size and drug loading capacities of micro/nanospheres were conducted before the immobilization process. Light microscopy and SEM were used to visualize and measure the size of the produced micro/nanospheres. Loaded and released drug amounts were determined by using UV- spectrophotometer at 278 nm. Finally, SEM analysis and drug release studies on the micro/nanospheres coated Ti surfaces were done. As a conclusion, it was shown that micro/nanospheres were immobilized onto the surfaces successfully and drug release from these surfaces was in a controlled manner. Moreover, the density of the micro/nanospheres after the drug release studies was higher on the surfaces where the entrapment technique was used for immobilization. Acknowledgement: This work is financially supported by The Scientific and Technological Research Council Of Turkey (Project # 217M220)

Keywords: chitosan, controlled drug release, nanosphere, nosocomial infections, titanium

Procedia PDF Downloads 110
36 The Healing 'Touch' of Music: A Neuro-Acoustics Approach to Understand Its Therapeutic Effect

Authors: Jagmeet S. Kanwal, Julia F. Langley

Abstract:

Music can heal the body, but a mechanistic understanding of this phenomenon is lacking. This study explores the effects of music presentation on neurologic and physiologic responses leading to metabolic changes in the human body. The mind and body co-exist in a corporeal entity and within this framework, sickness ensues when the mind-body balance goes awry. It is further hypothesized that music has the capacity to directly reset this balance. Two lines of inquiry taken together can provide a mechanistic understanding of this phenomenon 1) Empirical evidence for a sound-sensitive pressure sensor system in the body, and 2) The notion of a “healing center” within the brain that is activated by specific patterns of sounds. From an acoustics perspective, music is spatially distributed as pressure waves ranging from a few cm to several meters in wavelength. These waves interact and propagate in three-dimensions in unique ways, depending on the wavelength. Furthermore, music creates dynamically changing wave-fronts. Frequencies between 200 Hz and 1 kHz generate wavelengths that range from 5'6" to 1 foot. These dimensions are in the range of the body size of most people making it plausible that these pressure waves can geometrically interact with the body surface and create distinct patterns of pressure stimulation across the skin surface. For humans, short wavelength, high frequency (> 200 Hz) sounds are best received via cochlear receptors. For low frequency (< 200 Hz), long wavelength sound vibrations, however, the whole body may act as an ideal receiver. A vast array of highly sensitive pressure receptors (Pacinian corpuscles) is present just beneath the skin surface, as well as in the tendons, bones, several organs in the abdomen, and the sexual organs. Per the available empirical evidence, these receptors contribute to music perception by allowing the whole body to function as a sound receiver, and knowledge of how they function is essential to fully understanding the therapeutic effect of music. Neuroscientific studies have established that music stimulates the limbic system that can trigger states of anxiety, arousal, fear, and other emotions. These emotional states of brain activity play a crucial role in filtering top-down feedback from thoughts and bottom-up sensory inputs to the autonomic system, which automatically regulates bodily functions. Music likely exerts its pleasurable and healing effects by enhancing functional and effective connectivity and feedback mechanisms between brain regions that mediate reward, autonomic, and cognitive processing. Stimulation of pressure receptors under the skin by low-frequency music-induced sensations can activate multiple centers in the brain, including the amygdala, the cingulate cortex, and nucleus accumbens. Melodies in music in the low (< 600 Hz) frequency range may augment auditory inputs after convergence of the pressure-sensitive inputs from the vagus nerve onto emotive processing regions within the limbic system. The integration of music-generated auditory and somato-visceral inputs may lead to a synergistic input to the brain that promotes healing. Thus, music can literally heal humans through “touch” as it energizes the brain’s autonomic system for restoring homeostasis.

Keywords: acoustics, brain, music healing, pressure receptors

Procedia PDF Downloads 143