Search results for: cone contrast sensitivity
3458 Evaluating the Effect of Nursing Ethics Education on Nursing Students' Sensitivity and Moral Judgments
Authors: Hsiao Lu Lee
Abstract:
This study was based Quasi-experimental design. The study explored the relationships of nursing ethics education, nursing students’ moral sensitivity and moral judgments in Taiwan. A total of 242 nursing students (NS) participated the study.The proposed teaching nursing ethics from 2 to 16 weeks. Three questionnaires were adopted in this study. First, Demographic of nursing students questionnaire; Second, the questionnaire is Taiwan’s Moral Sensitivity Questionnaire for Student Nurses (TMMSQ-SN); Third, Defining Issues Test (DIT). The pre-test data were collected during the first week, and the post-test data was collected during the 17ᵗʰ week of the semester. The purpose of the study is explored evaluating the effect of nursing ethics education on nursing students’ moral sensitivity and moral judgments. The results of the study showed that moral sensitivities and moral judgments have been significantly improved after 16 weeks (Pair-t=--11.10***; Pair-t=-7.393***). Moral sensitivities and moral judgments were significant in the pretest. There was a negative correlation, but there was no correlation between moral sensitivity and moral judgments in the post-test. There was a significant correlation between the moral judgments (DIT)and the hours of work and other ethical courses (r=.28**; r=.015*). Nursing ethics education is necessary for nursing students in Taiwan. The nursing ethics courses are necessary to improve nursing students’ moral sensitivity and moral judgment (DIT).Keywords: defining issues test, moral judgments, moral sensitivity, nursing ethics education, nursing students
Procedia PDF Downloads 2773457 The Design, Development, and Optimization of a Capacitive Pressure Sensor Utilizing an Existing 9DOF Platform
Authors: Andrew Randles, Ilker Ocak, Cheam Daw Don, Navab Singh, Alex Gu
Abstract:
Nine Degrees of Freedom (9 DOF) systems are already in development in many areas. In this paper, an integrated pressure sensor is proposed that will make use of an already existing monolithic 9 DOF inertial MEMS platform. Capacitive pressure sensors can suffer from limited sensitivity for a given size of membrane. This novel pressure sensor design increases the sensitivity by over 5 times compared to a traditional array of square diaphragms while still fitting within a 2 mm x 2 mm chip and maintaining a fixed static capacitance. The improved design uses one large diaphragm supported by pillars with fixed electrodes placed above the areas of maximum deflection. The design optimization increases the sensitivity from 0.22 fF/kPa to 1.16 fF/kPa. Temperature sensitivity was also examined through simulation.Keywords: capacitive pressure sensor, 9 DOF, 10 DOF, sensor, capacitive, inertial measurement unit, IMU, inertial navigation system, INS
Procedia PDF Downloads 5473456 Evaluation of Forming Properties on AA 5052 Aluminium Alloy by Incremental Forming
Authors: A. Anbu Raj, V. Mugendiren
Abstract:
Sheet metal forming is a vital manufacturing process used in automobile, aerospace, agricultural industries, etc. Incremental forming is a promising process providing a short and inexpensive way of forming complex three-dimensional parts without using die. The aim of this research is to study the forming behaviour of AA 5052, Aluminium Alloy, using incremental forming and also to study the FLD of cone shape AA 5052 Aluminium Alloy at room temperature and various annealing temperature. Initially the surface roughness and wall thickness through incremental forming on AA 5052 Aluminium Alloy sheet at room temperature is optimized by controlling the effects of forming parameters. The central composite design (CCD) was utilized to plan the experiment. The step depth, feed rate, and spindle speed were considered as input parameters in this study. The surface roughness and wall thickness were used as output response. The process performances such as average thickness and surface roughness were evaluated. The optimized results are taken for minimum surface roughness and maximum wall thickness. The optimal results are determined based on response surface methodology and the analysis of variance. Formability Limit Diagram is constructed on AA 5052 Aluminium Alloy at room temperature and various annealing temperature by using optimized process parameters from the response surface methodology. The cone has higher formability than the square pyramid and higher wall thickness distribution. Finally the FLD on cone shape and square pyramid shape at room temperature and the various annealing temperature is compared experimentally and simulated with Abaqus software.Keywords: incremental forming, response surface methodology, optimization, wall thickness, surface roughness
Procedia PDF Downloads 3383455 A Comparison Study of Different Methods Used in the Detection of Giardia lamblia on Fecal Specimen of Children
Authors: Muhammad Farooq Baig
Abstract:
Objective: The purpose of this study was to compare results obtained using a single fecal specimen for O&P examination, direct immunofluorescence assay (DFA), and two conventional staining methods. Design: Hundred and fifty children fecal specimens were collected and examined by each method. The O&P and the DFA were used as the reference method. Setting: The study was performed at the laboratory in the Basic Medical Science Institute JPMC Karachi. Patients or Other Participants: The fecal specimens were collected from children with a suspected Giardia lamblia infection. Main Outcome Measures: The amount of agreement and disagreement between methods.1) Presence of giardiasis in our population. 2) The sensitivity and specificity of each method. Results: There was 45(30%) positive 105 (70%) negative on DFA, 41 (27.4%) positive 109 (72.6%) negative on iodine and 34 (22.6%) positive 116(77.4%) on saline method. The sensitivity and specificity of DFA in comparision to iodine were 92.2%, 92.7% respectively. The sensitivity and specificity of DFA in comparisoin to saline method were 91.2%, 87.9% respectively. The sensitivity of iodine method and saline method in compariosn to DFA were 82.2%, 68.8% respectively. There is mark diffrence in sensitivity of DFA to conventional method. Conclusion: The study supported findings of other investigators who concluded that DFA method have the greater sensitivity. The immunologic methods were more efficient and quicker than the conventional O&P method.Keywords: direct immunofluorescence assay (DFA), ova and parasite (O&P), Giardia lamblia, children, medical science
Procedia PDF Downloads 4253454 Gadolinium-Based Polymer Nanostructures as Magnetic Resonance Imaging Contrast Agents
Authors: Franca De Sarno, Alfonso Maria Ponsiglione, Enza Torino
Abstract:
Recent advances in diagnostic imaging technology have significantly contributed to a better understanding of specific changes associated with diseases progression. Among different imaging modalities, Magnetic Resonance Imaging (MRI) represents a noninvasive medical diagnostic technique, which shows low sensitivity and long acquisition time and it can discriminate between healthy and diseased tissues by providing 3D data. In order to improve the enhancement of MRI signals, some imaging exams require intravenous administration of contrast agents (CAs). Recently, emerging research reports a progressive deposition of these drugs, in particular, gadolinium-based contrast agents (GBCAs), in the body many years after multiple MRI scans. These discoveries confirm the need to have a biocompatible system able to boost a clinical relevant Gd-chelate. To this aim, several approaches based on engineered nanostructures have been proposed to overcome the common limitations of conventional CAs, such as the insufficient signal-to-noise ratios due to relaxivity and poor safety profile. In particular, nanocarriers, labeling or loading with CAs, capable of carrying high payloads of CAs have been developed. Currently, there’s no a comprehensive understanding of the thermodynamic contributions enable of boosting the efficacy of conventional CAs by using biopolymers matrix. Thus, considering the importance of MRI in diagnosing diseases, here it is reported a successful example of the next generation of these drugs where the commercial gadolinium chelate is incorporate into a biopolymer nanostructure, formed by cross-linked hyaluronic acid (HA), with improved relaxation properties. In addition, they are highlighted the basic principles ruling biopolymer-CA interactions in the perspective of their influence on the relaxometric properties of the CA by adopting a multidisciplinary experimental approach. On the basis of these discoveries, it is clear that the main point consists in increasing the rigidification of readily-available Gd-CAs within the biopolymer matrix by controlling the water dynamics, the physicochemical interactions, and the polymer conformations. In the end, the acquired knowledge about polymer-CA systems has been applied to develop of Gd-based HA nanoparticles with enhanced relaxometric properties.Keywords: biopolymers, MRI, nanoparticles, contrast agent
Procedia PDF Downloads 1503453 Anxiety Sensitivity and Coping Motives Predict Substance Use Craving and Relapse
Authors: Ruhollah Heydari Sheikh Ahmad, Sara Alaie Khoraem
Abstract:
Introduction: Substance use disorder is conceptualized as a chronic relapsing condition where relapse is usually defined as the return to problematic substance use following treatment. An issue of great importance is the identification of the predictors of relapse and the development of treatments that may help prevent relapse. One of the strongest predictors of relapse is craving. The purpose of the present study was to study the effect of anxiety, anxiety sensitivity, and coping motives on craving. Materials and method: Participants (n=74) were male opiate users recruited from a semi-private clinic providing de-toxification and treatment services for substance users. Anxiety, anxiety sensitivity, coping motives and craving were assessed using relevant questionnaires. The addiction severity index was used to assess addiction severity. Results: All patients were methadone maintained and one year after detoxification, 36 patients (48.64%) relapsed. Stress and anxiety, anxiety sensitivity, addiction severity and coping motives predicted craving and relapse. Anxiety sensitivity specifically predicted early relapse. Conclusion: Substance use is a severe mental disorder, with high relapse rates. Substance users high in anxiety sensitivity are particularly prone to relapse during the first six months of treatment. Addiction severity and coping motives need to be taken into account when providing interventional services for substance users. Findings imply the significance of additional psychological attention to methadone maintained patients to prevent craving and relapse.Keywords: anxiety sensitivity, coping motives, relapse, substance use craving
Procedia PDF Downloads 2963452 Effect of Threshold Configuration on Accuracy in Upper Airway Analysis Using Cone Beam Computed Tomography
Authors: Saba Fahham, Supak Ngamsom, Suchaya Damrongsri
Abstract:
Objective: The objective is to determine the optimal threshold of Romexis software for the airway volume and minimum cross-section area (MCA) analysis using Image J as a gold standard. Materials and Methods: A total of ten cone-beam computed tomography (CBCT) images were collected. The airway volume and MCA of each patient were analyzed using the automatic airway segmentation function in the CBCT DICOM viewer (Romexis). Airway volume and MCA measurements were conducted on each CBCT sagittal view with fifteen different threshold values from the Romexis software, Ranging from 300 to 1000. Duplicate DICOM files, in axial view, were imported into Image J for concurrent airway volume and MCA analysis as the gold standard. The airway volume and MCA measured from Romexis and Image J were compared using a t-test with Bonferroni correction, and statistical significance was set at p<0.003. Results: Concerning airway volume, thresholds of 600 to 850 as well as 1000, exhibited results that were not significantly distinct from those obtained through Image J. Regarding MCA, employing thresholds from 400 to 850 within Romexis Viewer showed no variance from Image J. Notably, within the threshold range of 600 to 850, there were no statistically significant differences observed in both airway volume and MCA analyses, in comparison to Image J. Conclusion: This study demonstrated that the utilization of Planmeca Romexis Viewer 6.4.3.3 within threshold range of 600 to 850 yields airway volume and MCA measurements that exhibit no statistically significant variance in comparison to measurements obtained through Image J. This outcome holds implications for diagnosing upper airway obstructions and post-orthodontic surgical monitoring.Keywords: airway analysis, airway segmentation, cone beam computed tomography, threshold
Procedia PDF Downloads 453451 Approximation of Convex Set by Compactly Semidefinite Representable Set
Authors: Anusuya Ghosh, Vishnu Narayanan
Abstract:
The approximation of convex set by semidefinite representable set plays an important role in semidefinite programming, especially in modern convex optimization. To optimize a linear function over a convex set is a hard problem. But optimizing the linear function over the semidefinite representable set which approximates the convex set is easy to solve as there exists numerous efficient algorithms to solve semidefinite programming problems. So, our approximation technique is significant in optimization. We develop a technique to approximate any closed convex set, say K by compactly semidefinite representable set. Further we prove that there exists a sequence of compactly semidefinite representable sets which give tighter approximation of the closed convex set, K gradually. We discuss about the convergence of the sequence of compactly semidefinite representable sets to closed convex set K. The recession cone of K and the recession cone of the compactly semidefinite representable set are equal. So, we say that the sequence of compactly semidefinite representable sets converge strongly to the closed convex set. Thus, this approximation technique is very useful development in semidefinite programming.Keywords: semidefinite programming, semidefinite representable set, compactly semidefinite representable set, approximation
Procedia PDF Downloads 3883450 The Impact of Ionic Strength on the Adsorption Behavior of Anionic and Cationic Dyes on Low Cost Biosorbent
Authors: Abdallah Bouguettoucha, Derradji Chebli, Sara Aga, Agueniou Fazia
Abstract:
The objective of this study was to looking for alternative materials (low cost) for the adsorption of textile dyes and optimizes the type which gives optimum adsorption and provides an explanation of the mechanism involved in the adsorption process. Adsorption of Orange II and Methylene blue on H2SO4 traited cone of Pinus brutia, was carried out at different initial concentrations of the dye (20, 50 and 100 mg / L) and at tow initial pH, pH 1 and 10 respectively. The models of Langmuir, Freundlich and Sips were used in this study to analyze the obtained results of the adsorption isotherm. PCB-0M had high adsorption capacities namely 32.8967 mg/g and 128.1651 mg/g, respectively for orange II and methylene blue and further indicated that the removal of dyes increased with increase in the ionic strength of solution, this was attributed to aggregation of dyes in solution. The potential of H2SO4 traited cone of Pinus brutia, an easily available and low cost material, to be used as an alternative biosorbent material for the removal of a dyes, Orange II and Methylene Bleu, from aqueous solutions was therefore confirmed.Keywords: Methylene blue, orange II, cones of pinus brutia, adsorption
Procedia PDF Downloads 2893449 Hypersensitivity Reactions Following Intravenous Administration of Contrast Medium
Authors: Joanna Cydejko, Paulina Mika
Abstract:
Hypersensitivity reactions are side effects of medications that resemble an allergic reaction. Anaphylaxis is a generalized, severe allergic reaction of the body caused by exposure to a specific agent at a dose tolerated by a healthy body. The most common causes of anaphylaxis are food (about 70%), Hymenoptera venoms (22%), and medications (7%), despite detailed diagnostics in 1% of people, the cause of the anaphylactic reaction was not indicated. Contrast media are anaphylactic agents of unknown mechanism. Hypersensitivity reactions can occur with both immunological and non-immunological mechanisms. Symptoms of anaphylaxis occur within a few seconds to several minutes after exposure to the allergen. Contrast agents are chemical compounds that make it possible to visualize or improve the visibility of anatomical structures. In the diagnosis of computed tomography, the preparations currently used are derivatives of the triiodide benzene ring. Pharmacokinetic and pharmacodynamic properties, i.e., their osmolality, viscosity, low chemotoxicity and high hydrophilicity, have an impact on better tolerance of the substance by the patient's body. In MRI diagnostics, macrocyclic gadolinium contrast agents are administered during examinations. The aim of this study is to present the results of the number and severity of anaphylactic reactions that occurred in patients in all age groups undergoing diagnostic imaging with intravenous administration of contrast agents. In non-ionic iodine CT and in macrocyclic gadolinium MRI. A retrospective assessment of the number of adverse reactions after contrast administration was carried out on the basis of data from the Department of Radiology of the University Clinical Center in Gdańsk, and it was assessed whether their different physicochemical properties had an impact on the incidence of acute complications. Adverse reactions are divided according to the severity of the patient's condition and the diagnostic method used in a given patient. Complications following the administration of a contrast medium in the form of acute anaphylaxis accounted for less than 0.5% of all diagnostic procedures performed with the use of a contrast agent. In the analysis period from January to December 2022, 34,053 CT scans and 15,279 MRI examinations with the use of contrast medium were performed. The total number of acute complications was 21, of which 17 were complications of iodine-based contrast agents and 5 of gadolinium preparations. The introduction of state-of-the-art contrast formulations was an important step toward improving the safety and tolerability of contrast agents used in imaging. Currently, contrast agents administered to patients are considered to be one of the best-tolerated preparations used in medicine. However, like any drug, they can be responsible for the occurrence of adverse reactions resulting from their toxic effects. The increase in the number of imaging tests performed with the use of contrast agents has a direct impact on the number of adverse events associated with their administration. However, despite the low risk of anaphylaxis, this risk should not be marginalized. The growing threat associated with the mass performance of radiological procedures with the use of contrast agents forces the knowledge of the rules of conduct in the event of symptoms of hypersensitivity to these preparations.Keywords: anaphylactic, contrast medium, diagnostic, medical imagine
Procedia PDF Downloads 633448 In-situ and Laboratory Characterization of Fiji Lateritic Soils
Authors: Faijal Ali, Darga Kumar N., Ravikant Singh, Rajnil Lal
Abstract:
Fiji has three major landforms such as plains, low mountains, and hills. The low land soils are formed on beach sand. Fiji soils contain high concentration of iron (III), aluminum oxides and hydroxides. The soil possesses reddish or yellowish colour. The characterization of lateritic soils collected from different locations along the national highway in Viti Levu, Fiji Islands. The research has been carried out mainly to understand the physical and strength properties to assess their suitability for the highway and building construction. In this paper, the field tests such as dynamic cone penetrometer test, field vane shear, field density and laboratory tests such as unconfined compression stress, compaction, grain size analysis and Atterberg limits are conducted. The test results are analyzed and presented. From the results, it is revealed that the soils are having more percentage of silt and clay which is more than 80% and 5 to 15% of fine to medium sand is noticed. The dynamic cone penetrometer results up to 3m depth had similar penetration resistance. For the first 1m depth, the rate of penetration is found 300mm per 3 to 4 blows. In all the sites it is further noticed that the rate of penetration at depths beyond 1.5 m is decreasing for the same number of blows as compared to the top soil. From the penetration resistance measured through dynamic cone penetrometer test, the California bearing ratio and allowable bearing capacities are 4 to 5% and 50 to 100 kPa for the top 1m layer and below 1m these values are increasing. The California bearing ratio of these soils for below 1m depth is in the order of 10% to 20%. The safe bearing capacity of these soils below 1m and up to 3m depth is varying from 150 kPa to 250 kPa. The field vane shear was measured within a depth of 1m from the surface and the values were almost similar varying from 60 kPa to 120 kPa. The liquid limit and plastic limits of these soils are in the range of 40 to 60% and 20 to 25%. Overall it is found that the top 1m soil along the national highway in majority places possess a soft to medium stiff behavior with low to medium bearing capacity as well low California bearing ratio values. It is recommended to ascertain these soils behavior in terms of geotechnical parameters before taking up any construction activity.Keywords: California bearing ratio, dynamic cone penetrometer test, field vane shear, unconfined compression stress.
Procedia PDF Downloads 1893447 Influence of Convective Boundary Condition on Chemically Reacting Micropolar Fluid Flow over a Truncated Cone Embedded in Porous Medium
Authors: Pradeepa Teegala, Ramreddy Chitteti
Abstract:
This article analyzes the mixed convection flow of chemically reacting micropolar fluid over a truncated cone embedded in non-Darcy porous medium with convective boundary condition. In addition, heat generation/absorption and Joule heating effects are taken into consideration. The similarity solution does not exist for this complex fluid flow problem, and hence non-similarity transformations are used to convert the governing fluid flow equations along with related boundary conditions into a set of nondimensional partial differential equations. Many authors have been applied the spectral quasi-linearization method to solve the ordinary differential equations, but here the resulting nonlinear partial differential equations are solved for non-similarity solution by using a recently developed method called the spectral quasi-linearization method (SQLM). Comparison with previously published work on special cases of the problem is performed and found to be in excellent agreement. The effect of pertinent parameters namely, Biot number, mixed convection parameter, heat generation/absorption, Joule heating, Forchheimer number, chemical reaction, micropolar and magnetic field on physical quantities of the flow are displayed through graphs and the salient features are explored in detail. Further, the results are analyzed by comparing with two special cases, namely, vertical plate and full cone wherever possible.Keywords: chemical reaction, convective boundary condition, joule heating, micropolar fluid, mixed convection, spectral quasi-linearization method
Procedia PDF Downloads 2773446 Allopurinol Prophylactic Therapy in the Prevention of Contrast Induced Nephropathy in High Risk Patients Undergoing Coronary Angiography: A Prospective Randomized Controlled Trial
Authors: Seyed Fakhreddin Hejazi, Leili Iranirad, Mohammad Sadeghi, Mohsen Talebizadeh
Abstract:
Background: Contrast-induced nephropathy (CIN) remains to be a potentially serious complication of radiographic procedures. We performed this clinical trial to assess the preventive effect of allopurinol against CIN in high-risk patients undergoing coronary angiography. Methods: In this prospective randomized controlled trial, 140 patients with at least two risk factors for CIN undergoing coronary angiography were randomly assigned to either the allopurinol group or the control group. Patients in the allopurinol group received 300 mg allopurinol 24 hours before a procedure and intravenous hydration for 12 hours before and after coronary angiography, whereas patients in the control group received intravenous hydration. Serum creatinine (SCr), blood urea nitrogen (BUN) and uric acid were measured before contrast exposure and at 48 hours. CIN was defined as an increase of 25% in serum creatinine (SCr) or >0.5 mg/dl 48 hours after contrast administration. Results: CIN occurred in 11 out of 70 (7.9%) patients in the control group and in 8 out of 70 (5.7%) patients in the allopurinol group. There was no significant difference in the incidence of CIN between the two groups at 48 hours after administering the radiocontrast agent (p = 0.459). However, there were significant differences between the two groups in SCr, BUN, uric acid, and eGFR 48 hours after radiocontrast administration (p < 0.05). Conclusion: Our findings revealed that allopurinol had no substantial efficacy over hydration protocol in high-risk patients for the development of CIN.Keywords: contrast-induced nephropathy, allopurinol, coronary angiography, contrast agent
Procedia PDF Downloads 2473445 Study of Contrast Induced Nephropathy in Patients Undergoing Cardiac Catheterization: Upper Egypt Experience
Authors: Ali Kassem, Sharf Eldeen-Shazly, Alshemaa Lotfy
Abstract:
Introduction: Contrast-induced nephropathy (CIN) has been the third leading cause of hospital-acquired renal failure. Patients with cardiac diseases are particularly at risk especially with repeated injections of contrast media. CIN is generally defined as an increase in serum creatinine concentration of > 0.5 mg/dL or 25% above baseline within 48 hours after contrast administration. Aim of work: To examine the frequency of CIN for patients undergoing cardiac catheterization at Sohag University Hospital (Upper Egypt) and to identify possible risk factors for CIN in these patients. Material and methods: The study included 104 patients with mean age 56.11 ±10.03, 64(61.5%) are males while 40(38.5%) are females. 44(42.3%) patients are diabetics, 43(41%) patients are hypertensive, 6(5.7%) patients have congestive heart failure, 69(66.3%) patients on statins, 74 (71.2 %) are on ACEIs or ARBs, 19(15.4%) are on metformin, 6 (5.8%) are on NSAIDs, 30(28.8%) are on diuretics. RESULTS: Patients were classified at the end of the study into two groups: Group A: Included 91 patients who did not develop CIN. Group B: Included 13 patients who developed CIN, of which serum creatinine raised > 0.5mg/dl in 6 patients and raised > 25% from the baseline after the procedure in 13 patients. The overall incidence of CIN was 12.5%. CIN increased with older age. There was an increase in the incidence of CIN in diabetic versus non-diabetic patients (20.5% and 6.7%) respectively. (p< 0.03). There was a highly significant increase in the incidence of CIN in patients with CHF versus those without CHF (100% and 71%) respectively, (P<0001). Patients on diuretics showed a significant increase in the incidence of CIN representing 61.5% of all patients who developed CIN. Conclusion: Older patients, diabetic patients, patients with CHF and patients on diuretics have higher risk of developing CIN during coronary catheterization and should receive reno-protective measures before contrast exposure.Keywords: cardiac diseases, contrast-induced nephropathy, coronary catheterization, CIN
Procedia PDF Downloads 3133444 The Effect of Deformation Activation Volume, Strain Rate Sensitivity and Processing Temperature of Grain Size Variants
Authors: P. B. Sob, A. A. Alugongo, T. B. Tengen
Abstract:
The activation volume of 6082T6 aluminum is investigated at different temperatures on grain size variants. The deformation activation volume was computed on the basis of the relationship between the Boltzmann’s constant k, the testing temperatures, the material strain rate sensitivity and the material yield stress of grain size variants. The material strain rate sensitivity is computed as a function of yield stress and strain rate of grain size variants. The effect of the material strain rate sensitivity and the deformation activation volume of 6082T6 aluminum at different temperatures of 3-D grain are discussed. It is shown that the strain rate sensitivities and activation volume are negative for the grain size variants during the deformation of nanostructured materials. It is also observed that the activation volume vary in different ways with the equivalent radius, semi minor axis radius, semi major axis radius and major axis radius. From the obtained results it is shown that the variation of activation volume increased and decreased with the testing temperature. It was revealed that, increased in strain rate sensitivity led to decrease in activation volume whereas increased in activation volume led to decrease in strain rate sensitivity.Keywords: nanostructured materials, grain size variants, temperature, yield stress, strain rate sensitivity, activation volume
Procedia PDF Downloads 2513443 A CMOS-Integrated Hall Plate with High Sensitivity
Authors: Jin Sup Kim, Min Seo
Abstract:
An improved cross-shaped hall plate with high sensitivity is described in this paper. Among different geometries that have been simulated and measured using Helmholtz coil. The paper describes the physical hall plate design and implementation in a 0.18-µm CMOS technology. In this paper, the biasing is a constant voltage mode. In the voltage mode, magnetic field is converted into an output voltage. The output voltage is typically in the order of micro- to millivolt and therefore, it must be amplified before being transmitted to the outside world. The study, design and performance optimization of hall plate has been carried out with the COMSOL Multiphysics. It is used to estimate the voltage distribution in the hall plate with and without magnetic field and to optimize the geometry. The simulation uses the nominal bias current of 1mA. The applied magnetic field is in the range from 0 mT to 20 mT. Measured results of the one structure over the 10 available samples show for the best sensitivity of 2.5 %/T at 20mT.Keywords: cross-shaped hall plate, sensitivity, CMOS technology, Helmholtz coil
Procedia PDF Downloads 1973442 Contrast Enhanced Magnetic Resonance Angiography in Rats with Gadobenate Dimeglumine at 3T
Authors: Jao Jo-Chi, Chen Yen-Ku, Jaw Twei-Shiun, Chen Po-Chou
Abstract:
This study aimed to investigate the magnetic resonance (MR) signal enhancement ratio (ER) of contrast-enhanced MR angiography (CE-MRA) in normal rats with gadobenate dimeglumine (Gd-BOPTA) using a clinical 3T scanner and an extremity coil. The relaxivities of Gd-BOPTA with saline only and with 4.5 % human serum albumin (HSA) were also measured. Compared with Gadolinium diethylenetriamine pentaacetic acid (Gd-DTPA), Gd-BOPTA had higher relaxivities. The maximum ER of Aorta (ERa), kidney, liver and muscle with Gd-BOPTA were higher than those with Gd-DTPA. The maximum ERa appeared at 1.2 min and decayed to half at 10 min after Gd-BOPTA injection. This information is helpful for the design of CE-MRA study of rats.Keywords: contrast-enhanced magnetic resonance angiography, Gd-BOPTA, Gd-DTPA, rat
Procedia PDF Downloads 6283441 Managing Incomplete PSA Observations in Prostate Cancer Data: Key Strategies and Best Practices for Handling Loss to Follow-Up and Missing Data
Authors: Madiha Liaqat, Rehan Ahmed Khan, Shahid Kamal
Abstract:
Multiple imputation with delta adjustment is a versatile and transparent technique for addressing univariate missing data in the presence of various missing mechanisms. This approach allows for the exploration of sensitivity to the missing-at-random (MAR) assumption. In this review, we outline the delta-adjustment procedure and illustrate its application for assessing the sensitivity to deviations from the MAR assumption. By examining diverse missingness scenarios and conducting sensitivity analyses, we gain valuable insights into the implications of missing data on our analyses, enhancing the reliability of our study's conclusions. In our study, we focused on assessing logPSA, a continuous biomarker in incomplete prostate cancer data, to examine the robustness of conclusions against plausible departures from the MAR assumption. We introduced several approaches for conducting sensitivity analyses, illustrating their application within the pattern mixture model (PMM) under the delta adjustment framework. This proposed approach effectively handles missing data, particularly loss to follow-up.Keywords: loss to follow-up, incomplete response, multiple imputation, sensitivity analysis, prostate cancer
Procedia PDF Downloads 903440 Effect of Bulk Density and Fiber Blend Content of Nonwoven Textiles on Flammability Properties
Authors: Klara Masnicova, Jiri Chaloupek
Abstract:
Flammability plays an important role in applications such as thermal and acoustic insulation and other technical nonwoven textiles. The study was conducted in an attempt to investigate the flammability behavior of nonwoven textiles in relation to their structural and material characteristics, with emphasis given to the blending ratios of flammable and non-flammable fibers or fibers with reduced flammability. Nonwoven structures made of blends of viscose/oxidized polyacrylonitrile (VS/oxidized PAN fibers and polyethylene terephthalate/oxidized polyacrylonitrile (PET/oxidized PAN) fibers in several bulk densities are evaluated. The VS/oxidized PAN blend is model material. The flammability was studied using a cone calorimeter. Reaction to fire was observed using the small flame test method. Interestingly, the results show some of the blending ratios do not react to the heat in linear response to bulk density. This outcome can have a huge impact on future product development in fire safety and for the general understanding of flammability behavior of nonwovens made of staple fibers.Keywords: bulk density, cone calorimetry, flammability, nonwoven textiles
Procedia PDF Downloads 3083439 Safety Effect of Smart Right-Turn Design at Intersections
Authors: Upal Barua
Abstract:
The risk of severe crashes at high-speed right-turns at intersections is a major safety concern these days. The application of a smart right-turn at an intersection is increasing day by day to address is an issue. The design, ‘Smart Right-turn’ consists of a narrow-angle of channelization at approximately 70°. This design increases the cone of vision of the right-tuning drivers towards the crossing pedestrians as well as traffic on the cross-road. As part of the Safety Improvement Program in Austin Transportation Department, several smart right-turns were constructed at high crash intersections where high-speed right-turns were found to be a contributing factor. This paper features the state of the art techniques applied in planning, engineering, designing and construction of this smart right-turn, key factors driving the success, and lessons learned in the process. This paper also presents the significant crash reductions achieved from the application of this smart right-turn design using Empirical Bayes method. The result showed that smart right-turns can reduce overall right-turn crashes by 43% and severe right-turn crashes by 70%.Keywords: smart right-turn, intersection, cone of vision, empirical Bayes method
Procedia PDF Downloads 2663438 Effects of Flame Retardant Nano Bio-Filler on the Fire Behaviour of Thin Film Intumescent Coatings
Authors: Ming Chian Yew, Ming Kun Yew, Lip Huat Saw, Tan Ching Ng, Rajkumar Durairaj, Jing Han Beh
Abstract:
This paper analyzes the fire protection performance, char formation and heat release characteristics of the thin film intumescent coatings that incorporate waste eggshell (ES) as a nano bio-filler. In this study, the Bunsen burner and the fire propagation (BS 476: Part 6) tests of coatings were measured. Experiments on the samples were also tested to evaluate their fire behavior using a cone calorimeter according to ISO 5660-1 specifications. On exposure, the samples B, C and D had been certified to be Class 0 due to the fire propagation indexes of the samples were less than 12. Samples B and D showed a significant reduction in total heat rate (B=11.6 MJ/m² and D=12.0 MJ/m²) and uniform char structures with the addition of 3.30 wt.% and 2.75 wt.% ES nano bio-filler, respectively. As a result, ES nano bio-filler composition good to slow down the fire expanding and demonstrate better fire protection due to its positive synergistic effect with flame retardant ingredients on physical and chemical reactions in fire protection.Keywords: cone calorimeter, eggshell, fire protection, heat release rate, intumescent coating
Procedia PDF Downloads 2723437 Failure Localization of Bipolar Integrated Circuits by Implementing Active Voltage Contrast
Authors: Yiqiang Ni, Xuanlong Chen, Enliang Li, Linting Zheng, Shizheng Yang
Abstract:
Bipolar ICs are playing an important role in military applications, mainly used in logic gates, such as inverter and NAND gate. The defect of metal break located on the step is one of the main failure mechanisms of bipolar ICs, resulting in open-circuit or functional failure. In this situation, general failure localization methods like optical beam-induced resistance change (OBIRCH) and photon emission microscopy (PEM) might not be fully effective. However, active voltage contrast (AVC) can be used as a voltage probe, which may pinpoint the incorrect potential and thus locate the failure position. Two case studies will be present in this paper on how to implement AVC for failure localization, and the detailed failure mechanism will be discussed.Keywords: bipolar IC, failure localization, metal break, open failure, voltage contrast
Procedia PDF Downloads 2943436 Survivability of Maneuvering Aircraft against Air to Air Infrared Missile
Authors: Ji-Yeul Bae, Hyung Mo Bae, Jihyuk Kim, Hyung Hee Cho
Abstract:
An air to air infrared missile poses a significant threat to the survivability of an aircraft due to an advanced sensitivity of sensor and maneuverability of the missile. Therefore, recent military aircraft is equipped with MAW (Missile Approach Warning) to take an evasive maneuver and to deploy countermeasures like chaff and flare. In this research, an effect of MAW sensitivity and resulting evasive maneuver on the survivability of the fighter aircraft is studied. A single engine fighter jet with Mach 0.9 flying at an altitude of 5 km is modeled in the research and infrared signature of the aircraft is calculated by numerical simulation. The survivability is assessed in terms of lethal range. The MAW sensitivity and maneuverability of an aircraft is used as variables. The result showed that improvement in survivability mainly achieved when the missile approach from the side of the aircraft. And maximum 30% increase in survivability of the aircraft is achieved when existence of the missile is noticed at 7 km distance. As a conclusion, sensitivity of the MAW seems to be more important factor than the maneuverability of the aircraft in terms of the survivability.Keywords: air to air missile, missile approach warning, lethal range, survivability
Procedia PDF Downloads 5683435 Understanding Consumption Planning Behaviors
Authors: Gaosheng Ju
Abstract:
Our empirical evidence supports a model of consumption planning behaviors with the following two characteristics. First, households formulate a rational consumption target based on their desired target, displaying a diminishing sensitivity to the discrepancy between them. Second, the established target is a reference point for their planned consumption. The diminishing sensitivity leads to opposite reactions in higher and lower quantiles of both consumption targets and consumption growth to changes in economic conditions. This phenomenon accounts for the perplexingly low correlation between consumption and other macroeconomic variables. Furthermore, the opposing movements of consumption targets offer new insights into consumption-based asset pricing.Keywords: consumption planning, reference point, diminishing sensitivity, quantile regression, asset pricing puzzles
Procedia PDF Downloads 833434 PD Test in Gas Insulated Substation Using UHF Method
Authors: T. Prabakaran
Abstract:
Gas Insulated Substations (GIS) are widely used as important switchgear equipment because of its high reliability, low space requirement, low risk factor and easy maintenance, yet some failures have been reported. Some of the failures are due to presence of metallic particles inside the GIS compartment. The defect can be generated in GIS during production, maintenance, installation and can be due to ageing of the component. The Ultra-High Frequency (UHF) method is used to diagnose the insulation condition of GIS by detecting the PD signals in GIS. This paper identifies PD patterns for free moving particle defect and particle fixed on cone using UHF method. As insulation failure usually starts with PD activity, this paper investigates the differences in PD characteristics in SF6 gas with different types of defects. Experimental results show that correct identification of defects can be achieved based on considered PD characteristics. The method can be applied to prove the quality of assembly work at commissioning, also on a regular basis after many years in service to detect aged and conducting particles as a part of the condition based maintenance.Keywords: gas insulated substation, partial discharge, free moving particle defect, particle fixed on cone defect, ultra high frequency method
Procedia PDF Downloads 2473433 Breaking Sensitivity Barriers: Perovskite Based Gas Sensors With Dimethylacetamide-Dimethyl Sulfoxide Solvent Mixture Strategy
Authors: Endalamaw Ewnu Kassa, Ade Kurniawan, Ya-Fen Wu, Sajal Biring
Abstract:
Perovskite-based gas sensors represent a highly promising materials within the realm of gas sensing technology, with a particular focus on detecting ammonia (NH3) due to its potential hazards. Our work conducted thorough comparison of various solvents, including dimethylformamide (DMF), DMF-dimethyl sulfoxide (DMSO), dimethylacetamide (DMAC), and DMAC-DMSO, for the preparation of our perovskite solution (MAPbI3). Significantly, we achieved an exceptional response at 10 ppm of ammonia gas by employing a binary solvent mixture of DMAC-DMSO. In contrast to prior reports that relied on single solvents for MAPbI3 precursor preparation, our approach using mixed solvents demonstrated a marked improvement in gas sensing performance. We attained enhanced surface coverage, a reduction in pinhole occurrences, and precise control over grain size in our perovskite films through the careful selection and mixtures of appropriate solvents. This study shows a promising potential of employing binary and multi-solvent mixture strategies as a means to propel advancements in gas sensor technology, opening up new opportunities for practical applications in environmental monitoring and industrial safety.Keywords: sensors, binary solvents, ammonia, sensitivity, grain size, pinholes, surface coverage
Procedia PDF Downloads 1093432 Non Interferometric Quantitative Phase Imaging of Yeast Cells
Authors: P. Praveen Kumar, P. Vimal Prabhu, Renu John
Abstract:
In biology most microscopy specimens, in particular living cells are transparent. In cell imaging, it is hard to create an image of a cell which is transparent with a very small refractive index change with respect to the surrounding media. Various techniques like addition of staining and contrast agents, markers have been applied in the past for creating contrast. Many of the staining agents or markers are not applicable to live cell imaging as they are toxic. In this paper, we report theoretical and experimental results from quantitative phase imaging of yeast cells with a commercial bright field microscope. We reconstruct the phase of cells non-interferometrically based on the transport of intensity equations (TIE). This technique estimates the axial derivative from positive through-focus intensity measurements. This technique allows phase imaging using a regular microscope with white light illumination. We demonstrate nano-metric depth sensitivity in imaging live yeast cells using this technique. Experimental results will be shown in the paper demonstrating the capability of the technique in 3-D volume estimation of living cells. This real-time imaging technique would be highly promising in real-time digital pathology applications, screening of pathogens and staging of diseases like malaria as it does not need any pre-processing of samples.Keywords: axial derivative, non-interferometric imaging, quantitative phase imaging, transport of intensity equation
Procedia PDF Downloads 3853431 Automatic Early Breast Cancer Segmentation Enhancement by Image Analysis and Hough Transform
Authors: David Jurado, Carlos Ávila
Abstract:
Detection of early signs of breast cancer development is crucial to quickly diagnose the disease and to define adequate treatment to increase the survival probability of the patient. Computer Aided Detection systems (CADs), along with modern data techniques such as Machine Learning (ML) and Neural Networks (NN), have shown an overall improvement in digital mammography cancer diagnosis, reducing the false positive and false negative rates becoming important tools for the diagnostic evaluations performed by specialized radiologists. However, ML and NN-based algorithms rely on datasets that might bring issues to the segmentation tasks. In the present work, an automatic segmentation and detection algorithm is described. This algorithm uses image processing techniques along with the Hough transform to automatically identify microcalcifications that are highly correlated with breast cancer development in the early stages. Along with image processing, automatic segmentation of high-contrast objects is done using edge extraction and circle Hough transform. This provides the geometrical features needed for an automatic mask design which extracts statistical features of the regions of interest. The results shown in this study prove the potential of this tool for further diagnostics and classification of mammographic images due to the low sensitivity to noisy images and low contrast mammographies.Keywords: breast cancer, segmentation, X-ray imaging, hough transform, image analysis
Procedia PDF Downloads 843430 Biologically Inspired Small Infrared Target Detection Using Local Contrast Mechanisms
Authors: Tian Xia, Yuan Yan Tang
Abstract:
In order to obtain higher small target detection accuracy, this paper presents an effective algorithm inspired by the local contrast mechanism. The proposed method can enhance target signal and suppress background clutter simultaneously. In the first stage, a enhanced image is obtained using the proposed Weighted Laplacian of Gaussian. In the second stage, an adaptive threshold is adopted to segment the target. Experimental results on two changeling image sequences show that the proposed method can detect the bright and dark targets simultaneously, and is not sensitive to sea-sky line of the infrared image. So it is fit for IR small infrared target detection.Keywords: small target detection, local contrast, human vision system, Laplacian of Gaussian
Procedia PDF Downloads 4693429 Advances in Axonal Biomechanics and Mechanobiology: A Nanotechnology-Based Approach to the Study of Mechanotransduction of Axonal Growth
Authors: Alessandro Falconieri, Sara De Vincentiis, Vittoria Raffa
Abstract:
Mechanical force regulates axonal growth, elongation and maturation processes. This force is opening new frontiers in the field, contributing to a general understanding of the mechanisms of axon growth that, in the past, was thought to be governed exclusively by the growth cone and its ability to influence axonal growth in response to chemical signals. A method recently developed in our laboratory allows, through the labeling of neurons with magnetic nanoparticles (MNPs) and the use of permanent magnets, to apply extremely low mechanical forces, similar to those generated endogenously by the growth cone or by the increase of body mass during the organism growth. We found that these extremely low forces strongly enhance the spontaneous axonal elongation rate as well as neuronal sprouting. Data obtained don’t exclude that local phenomena, such as local transport and local translation, may be involved. These new advances could shed new light on what happens when the cell is subjected to external mechanical forces, opening new interesting scenarios in the field of mechanobiology.Keywords: axon, external mechanical forces, magnetic nanoparticles, mechanotransduction
Procedia PDF Downloads 124