Search results for: percutaneous pinning
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 79

Search results for: percutaneous pinning

49 Work-Related Risk Factors and Preventive Measures among Nurses and Dentists at Faculty of Oral and Dental Medicine

Authors: Marwa Mamdouh Shaban, Nagat Saied Habib, Shireen Ezz El-Din Taha, Eman Mahmoud Seif El-Naser

Abstract:

Background: Dental nurses and dentists were constantly exposed to a number of specific work related health risk factors which develop and intensify with years. Awareness regarding these work-related health risk factors and implementation of preventive health care measures could provide a safe work environment for all dental nurses and dentists. Aim of the study: to assess the work-related health risk factors among dental nurses and dentists and preventive health care measures applied among dental nurses and dentists. Research design: A descriptive design was utilized. Sample: Convenience sample of 50 dental nurses and 150 dentists were included in the current study. Setting: This study was conducted at the dental clinics at faculty of oral and dental medicine, Al-Kasr Al Ainy Hospital. Tools of data collection: Three tools were developed, tested for clarity, and feasibility: a-Socio-demographic data sheet, b-Work-related health risk factors questionnaire, and c-structured observational checklist. Results: The most common work risk factors prevailing among dental nurses were emotional exhaustion (82%), low back pain (76%) and latex allergy (62%) and the most common work risk factors prevailing among dentists were percutaneous exposure incident (100%), emotional exhaustion (100%) and low back pain (93.3%). Also, statistically significant negative correlation (r=-0.274, at p = 0.045) between the incidence of chemical health risk factors and application of chemical preventive measures among dental nurses. A statistically significant negative correlation (r=-0.177, at p = 0.030) between the incidences of mechanical health risk factors among dentists and application of mechanical preventive measures. Conclusion: The studied dental nurses and dentists exposed to many work related health risk factors as latex allergy, percutaneous exposure incidents, low back pain and emotional exhaustion related to inappropriate application of preventive health care measures. Recommendation: Raise awareness of dental nurses and dentists about work-related health risk factors, design and implement health education program for preventive health care measures.

Keywords: work-related risk factors, preventive measures, nurses, dentists

Procedia PDF Downloads 375
48 Impact of Diabetes Mellitus Type 2 on Clinical In-Stent Restenosis in First Elective Percutaneous Coronary Intervention Patients

Authors: Leonard Simoni, Ilir Alimehmeti, Ervina Shirka, Endri Hasimi, Ndricim Kallashi, Verona Beka, Suerta Kabili, Artan Goda

Abstract:

Background: Diabetes Mellitus type 2, small vessel calibre, stented length of vessel, complex lesion morphology, and prior bypass surgery have resulted risk factors for In-Stent Restenosis (ISR). However, there are some contradictory results about body mass index (BMI) as a risk factor for ISR. Purpose: We want to identify clinical, lesional and procedural factors that can predict clinical ISR in our patients. Methods: Were enrolled 759 patients who underwent first-time elective PCI with Bare Metal Stents (BMS) from September 2011 to December 2013 in our Department of Cardiology and followed them for at least 1.5 years with a median of 862 days (2 years and 4 months). Only the patients re-admitted with ischemic heart disease underwent control coronary angiography but no routine angiographic control was performed. Patients were categorized in ISR and non-ISR groups and compared between them. Multivariate analysis - Binary Logistic Regression: Forward Conditional Method was used to identify independent predictive risk factors. P was considered statistically significant when <0.05. Results: ISR compared to non-ISR individuals had a significantly lower BMI (25.7±3.3 vs. 26.9±3.7, p=0.004), higher risk anatomy (LM + 3-vessel CAD) (23% vs. 14%, p=0.03), higher number of stents/person used (2.1±1.1 vs. 1.75±0.96, p=0.004), greater length of stents/person used (39.3±21.6 vs. 33.3±18.5, p=0.01), and a lower use of clopidogrel and ASA (together) (95% vs. 99%, p=0.012). They also had a higher, although not statistically significant, prevalence of Diabetes Mellitus (42% vs. 32%, p=0.072) and a greater number of treated vessels (1.36±0.5 vs. 1.26±0.5, p=0.08). In the multivariate analysis, Diabetes Mellitus type 2 and multiple stents used were independent predictors risk factors for In-Stent Restenosis, OR 1.66 [1.03-2.68], p=0.039, and OR 1.44 [1.16-1.78,] p=0.001, respectively. On the other side higher BMI and use of clopidogrel and ASA together resulted protective factors OR 0.88 [0.81-0.95], p=0.001 and OR 0.2 [0.06-0.72] p=0.013, respectively. Conclusion: Diabetes Mellitus and multiple stents are strong predictive risk factors, whereas the use of clopidogrel and ASA together are protective factors for clinical In-Stent Restenosis. Paradoxically High BMI is a protective factor for In-stent Restenosis, probably related to a larger diameter of vessels and consequently a larger diameter of stents implanted in these patients. Further studies are needed to clarify this finding.

Keywords: body mass index, diabetes mellitus, in-stent restenosis, percutaneous coronary intervention

Procedia PDF Downloads 184
47 Semiconductor Nanofilm Based Schottky-Barrier Solar Cells

Authors: Mariyappan Shanmugam, Bin Yu

Abstract:

Schottky-barrier solar cells are demonstrated employing 2D-layered MoS2 and WS2 semiconductor nanofilms as photo-active material candidates synthesized by chemical vapor deposition method. Large area MoS2 and WS2 nanofilms are stacked by layer transfer process to achieve thicker photo-active material studied by atomic force microscopy showing a thickness in the range of ~200 nm. Two major vibrational active modes associated with 2D-layered MoS2 and WS2 are studied by Raman spectroscopic technique to estimate the quality of the nanofilms. Schottky-barrier solar cells employed MoS2 and WS2 active materials exhibited photoconversion efficiency of 1.8 % and 1.7 % respectively. Fermi-level pinning at metal/semiconductor interface, electronic transport and possible recombination mechanisms are studied in the Schottky-barrier solar cells.

Keywords: two-dimensional nanosheet, graphene, hexagonal boron nitride, solar cell, Schottky barrier

Procedia PDF Downloads 308
46 Endoscopic Stenting of the Main Pancreatic Duct in Patients With Pancreatic Fluid Collections After Pancreas Transplantation

Authors: Y. Teterin, S. Suleymanova, I. Dmitriev, P. Yartcev

Abstract:

Introduction: One of the most common complications after pancreas transplantation are pancreatic fluid collections (PFCs), which are often complicated not only by infection and subsequent disfunction of the pancreatoduodenal graft (PDG), but also with a rather high mortality rate of recipients. Drainage is not always effective and often requires repeated open surgical interventions, which worsens the outcome of the surgery. Percutaneous drainage of PFCs combined with endoscopic stenting of the main pancreatic duct of the pancreatoduodenal graft (MPDPDG) showed high efficiency in the treatment of PFCs. Aims & Methods: From 01.01.2012 to 31.12.2021 at the Sklifosovsky Research Institute for Emergency Medicine were performed 64 transplantations of PDG. In 11 cases (17.2%), the early postoperative period was complicated by the formation of PFCs. Of these, 7 patients underwent percutaneous drainage of pancreonecrosis with high efficiency and did not required additional methods of treatment. In the remaining 4 patients, drainage was ineffective and was an indication for endoscopic stenting of the MPDPDG. They were the ones who made up the study group. Among them were 3 men and 1 woman. The mean age of the patients was 36,4 years.PFCs in these patients formed on days 1, 12, 18, and 47 after PDG transplantation. We used a gastroscope to stent the MPDPDG, due to anatomical features of the location of the duodenoduodenal anastomosis after PDG transplantation. Through the endoscope channel was performed selective catheterization of the MPDPDG, using a catheter and a guidewire, followed by its contrasting with a water-soluble contrast agent. Due to the extravasation of the contrast, was determined the localization of the defect in the PDG duct system. After that, a plastic pancreatic stent with a diameter of 7 Fr. and a length of 7 cm. was installed along guidewire. The stent was installed in such a way that its proximal edge completely covered the defect zone, and the distal one was determined in the intestinal lumen. Results: In all patients PDG pancreaticography revealed extravasation of a contrast in the area of the isthmus and body of the pancreas, which required stenting of the MPDPDG. In 1 (25%) case, the patient had a dislocation of the stent into the intestinal lumen (III degree according to Clavien-Dindo (2009)). This patient underwent repeated endoscopic stenting of the MPDPDG. On average 23 days after endoscopic stenting of the MPDPDG, the drainage tubes were removed and after approximately 40 days all patients were discharged in a satisfactory condition with follow-up endocrinologist and surgeon consultation. Pancreatic stents were removed after 6 months ± 7 days. Conclusion: Endoscopic stenting of the main pancreatic duct of the donor pancreas is by far the most highly effective and minimally invasive method in the treatment of PFCs after transplantation of the pancreatoduodenal complex.

Keywords: pancreas transplantation, endoscopy surgery, diabetes, stenting, main pancreatic duct

Procedia PDF Downloads 68
45 A Hyperflexion Hallux Mallet Injury: A Case Report

Authors: Tan G. K. Y., Chew M. S. J., Sajeev S., Vellasamy A.

Abstract:

Injuries of the extensor hallucis longus (EHL) tendon are a rare phenomenon, with most occurring due to lacerations or penetrating injuries. Closed traumatic ruptures of the EHL are described as “Mallet injuries of the toe”. These can be classified as bony or soft mallet injuries depending on the presence or absence of a fracture at the insertion site of the EHL tendon in the distal phalanx. We present a case of a 33-year-old woman who presented with a hyperflexion injury to the left big toe with an inability to extend the big toe. Ultrasound showed a complete rupture of the EHL tendon with retraction proximal to the hallucal interphalangeal joint of the big toe. The patient was treated through transarticular pinning and repair using the Arthrex Mini Bio-Suture Tak with a 2-0 fibre wire. Six months postoperatively, the patient had symmetrical EHL power and full range of motion of the toe. The lessons to be drawn from this case report are that isolated hallux mallet injuries are rare and can be easily missed in the absence of penetrating wounds. Patients who have such injuries should be investigated early with the appropriate imaging techniques, such as ultrasound or MRI, and treated surgically.

Keywords: hallux mallet, extensor hallucis longus tendon, extensor hallucis longus

Procedia PDF Downloads 60
44 Lowering Error Floors by Concatenation of Low-Density Parity-Check and Array Code

Authors: Cinna Soltanpur, Mohammad Ghamari, Behzad Momahed Heravi, Fatemeh Zare

Abstract:

Low-density parity-check (LDPC) codes have been shown to deliver capacity approaching performance; however, problematic graphical structures (e.g. trapping sets) in the Tanner graph of some LDPC codes can cause high error floors in bit-error-ratio (BER) performance under conventional sum-product algorithm (SPA). This paper presents a serial concatenation scheme to avoid the trapping sets and to lower the error floors of LDPC code. The outer code in the proposed concatenation is the LDPC, and the inner code is a high rate array code. This approach applies an interactive hybrid process between the BCJR decoding for the array code and the SPA for the LDPC code together with bit-pinning and bit-flipping techniques. Margulis code of size (2640, 1320) has been used for the simulation and it has been shown that the proposed concatenation and decoding scheme can considerably improve the error floor performance with minimal rate loss.

Keywords: concatenated coding, low–density parity–check codes, array code, error floors

Procedia PDF Downloads 335
43 Xiaflex (Collagenase) Impact on the Management of Dupuytren's Disease: Making the Case for Treatment in a Public Healthcare System

Authors: Anthony Barker, Roland Jiang

Abstract:

Dupuytren’s contractures are a debilitating condition affecting the palmar fascia of the hand reducing its function. This case series looks at the minimally-invasive technique of Xiaflex injections and the outcome in a public health setting. 15 patients undertook collagenase injection (Xiaflex, C. histolyticum) injection over the period from September 2015 to May 2017 at Fairfield Hospital, NSW. Their reported outcome post injection and in follow-up was recorded as well as their satisfaction and likelihood to request the procedure in the future. Other treatment modalities include percutaneous needle aponeurotomy, limited palmar fasciotomy, and palmar fasciectomy. A literature review of cost-effectiveness was performed to compare Xiaflex suitability for waitlist reduction in a public setting given average waiting times in the public setting extend past 365 days.

Keywords: Dupuytrens Disease, xiaflex, collagenase, plastic surgery

Procedia PDF Downloads 165
42 The Effect of Choke on the Efficiency of Coaxial Antenna for Percutaneous Microwave Coagulation Therapy for Hepatic Tumor

Authors: Surita Maini

Abstract:

There are many perceived advantages of microwave ablation have driven researchers to develop innovative antennas to effectively treat deep-seated, non-resectable hepatic tumors. In this paper a coaxial antenna with a miniaturized sleeve choke has been discussed for microwave interstitial ablation therapy, in order to reduce backward heating effects irrespective of the insertion depth into the tissue. Two dimensional Finite Element Method (FEM) is used to simulate and measure the results of miniaturized sleeve choke antenna. This paper emphasizes the importance of factors that can affect simulation accuracy, which include mesh resolution, surface heating and reflection coefficient. Quarter wavelength choke effectiveness has been discussed by comparing it with the unchoked antenna with same dimensions.

Keywords: microwave ablation, tumor, finite element method, coaxial slot antenna, coaxial dipole antenna

Procedia PDF Downloads 336
41 A Crystal Plasticity Approach to Model Dynamic Strain Aging

Authors: Burak Bal, Demircan Canadinc

Abstract:

Dynamic strain aging (DSA), resulting from the reorientation of C-Mn clusters in the core of dislocations, can provide a strain hardening mechanism. In addition, in Hadfield steel, negative strain rate sensitivity is observed due to the DSA. In our study, we incorporated dynamic strain aging onto crystal plasticity computations to predict the local instabilities and corresponding negative strain rate sensitivity. Specifically, the material response of Hadfield steel was obtained from monotonic and strain-rate jump experiments under tensile loading. The strain rate range was adjusted from 10⁻⁴ to 10⁻¹s ⁻¹. The crystal plasticity modeling of the material response was carried out based on Voce-type hardening law and corresponding Voce hardening parameters were determined. The solute pinning effect of carbon atom was incorporated to crystal plasticity simulations at microscale level by computing the shear stress contribution imposed on an arrested dislocation by carbon atom. After crystal plasticity simulations with modifying hardening rule, which takes into account the contribution of DSA, it was seen that the model successfully predicts both the role of DSA and corresponding strain rate sensitivity.

Keywords: crystal plasticity, dynamic strain aging, Hadfield steel, negative strain rate sensitivity

Procedia PDF Downloads 240
40 Non-Invasive Evaluation of Patients After Percutaneous Coronary Revascularization. The Role of Cardiac Imaging

Authors: Abdou Elhendy

Abstract:

Numerous study have shown the efficacy of the percutaneous intervention (PCI) and coronary stenting in improving left ventricular function and relieving exertional angina. Furthermore, PCI remains the main line of therapy in acute myocardial infarction. Improvement of procedural techniques and new devices have resulted in an increased number of PCI in those with difficult and extensive lesions, multivessel disease as well as total occlusion. Immediate and late outcome may be compromised by acute thrombosis or the development of fibro-intimal hyperplasia. In addition, progression of coronary artery disease proximal or distal to the stent as well as in non-stented arteries is not uncommon. As a result, complications can occur, such as acute myocardial infarction, worsened heart failure or recurrence of angina. In a stent, restenosis can occur without symptoms or with atypical complaints rendering the clinical diagnosis difficult. Routine invasive angiography is not appropriate as a follow up tool due to associated risk and cost and the limited functional assessment. Exercise and pharmacologic stress testing are increasingly used to evaluate the myocardial function, perfusion and adequacy of revascularization. Information obtained by these techniques provide important clues regarding presence and severity of compromise in myocardial blood flow. Stress echocardiography can be performed in conjunction with exercise or dobutamine infusion. The diagnostic accuracy has been moderate, but the results provide excellent prognostic stratification. Adding myocardial contrast agents can improve imaging quality and allows assessment of both function and perfusion. Stress radionuclide myocardial perfusion imaging is an alternative to evaluate these patients. The extent and severity of wall motion and perfusion abnormalities observed during exercise or pharmacologic stress are predictors of survival and risk of cardiac events. According to current guidelines, stress echocardiography and radionuclide imaging are considered to have appropriate indication among patients after PCI who have cardiac symptoms and those who underwent incomplete revascularization. Stress testing is not recommended in asymptomatic patients, particularly early after revascularization, Coronary CT angiography is increasingly used and provides high sensitive for the diagnosis of coronary artery stenosis. Average sensitivity and specificity for the diagnosis of in stent stenosis in pooled data are 79% and 81%, respectively. Limitations include blooming artifacts and low feasibility in patients with small stents or thick struts. Anatomical and functional cardiac imaging modalities are corner stone for the assessment of patients after PCI and provide salient diagnostic and prognostic information. Current imaging techniques cans serve as gate keeper for coronary angiography, thus limiting the risk of invasive procedures to those who are likely to benefit from subsequent revascularization. The determination of which modality to apply requires careful identification of merits and limitation of each technique as well as the unique characteristic of each individual patient.

Keywords: coronary artery disease, stress testing, cardiac imaging, restenosis

Procedia PDF Downloads 139
39 Grape Seed Extract and Zinc Containing Multivitamin-Mineral Nutritional Food Supplement Protects Heart against Myocardial Ischemic-Reperfusion Injury in Wistar Rats

Authors: S. M. Satyam, K. L. Bairy, R. Pirasanthan, R. L. Vaishnav

Abstract:

Zincovit tablets have been used as nutritional food supplement over a prolonged period of time. The aim of the present study was to investigate the cardio-protective effect of combined formulation of grape seed extract and Zincovit tablets (40, 80 and 160 mg/kg) using a Langendorff model of ischemia-reperfusion in Wistar rats. Following 21 days of pre-treatment, combined formulation of grape seed extract and Zincovit tablets significantly attenuated ischemia-reperfusion induced cardiac injury in terms of increased coronary flow rate (p < 0.01), decreased creatine kinase activity in coronary effluent (p < 0.05), decreased MDA (p < 0.001), 4-HNE (p < 0.001) and increased protein thiol content (p < 0.01) in comparison with the untreated (control) group. This study opens an avenue to clinical studies to demonstrate the validity of this paradigm as a nutritional food supplement, which could improve the clinical outcome of patients subjected to percutaneous angioplasty.

Keywords: grape seed extract, myocardial ischemia-reperfusion injury, oxidative stress, Zincovit tablets

Procedia PDF Downloads 356
38 The Twelfth Rib as a Landmark for Surgery

Authors: Jake Tempo, Georgina Williams, Iain Robertson, Claire Pascoe, Darren Rama, Richard Cetti

Abstract:

Introduction: The twelfth rib is commonly used as a landmark for surgery; however, its variability in length has not been formally studied. The highly variable rib length provides a challenge for urologists seeking a consistent landmark for percutaneous nephrolithotomy and retroperitoneoscopic surgery. Methods and materials: We analysed CT scans of 100 adults who had imaging between 23rd March and twelfth April 2020 at an Australian Hospital. We measured the distance from the mid-sagittal line to the twelfth rib tip in the axial plane as a surrogate for true rib length. We also measured the distance from the twelfth rib tip to the kidney, spleen, and liver. Results: Length from the mid-sagittal line to the right twelfth rib tip varied from 46 (percentile 95%CI 40 to 57) to 136mm (percentile 95%CI 133 to 138). On the left, the distances varied from 55 (percentile 95%CI 50 to 64) to 134mm (percentile 95%CI 131 to 135). Twenty-three percent of people had an organ lying between the tip of the twelfth rib and the kidney on the right, and 11% of people had the same finding on the left. Conclusion: The twelfth rib is highly variable in its length. Similar variability was recorded in the distance from the tip to intra-abdominal organs. Due to the frequency of organs lying between the tip of the rib and the kidney, it should not be used as a landmark for accessing the kidney without prior knowledge of an individual patient’s anatomy, as seen on imaging.

Keywords: PCNL, rib, anatomy, nephrolithotomy

Procedia PDF Downloads 88
37 Influence of Aluminium on Grain Refinement in As-Rolled Vanadium-Microalloyed Steels

Authors: Kevin Mark Banks, Dannis Rorisang Nkarapa Maubane, Carel Coetzee

Abstract:

The influence of aluminium content, reheating temperature, and sizing (final) strain on the as-rolled microstructure was systematically investigated in vanadium-microalloyed and C-Mn plate steels. Reheating, followed by hot rolling and air cooling simulations were performed on steels containing a range of aluminium and nitrogen contents. Natural air cooling profiles, corresponding to 6 and 20mm thick plates, were applied. The austenite and ferrite/pearlite microstructures were examined using light optical microscopy. Precipitate species and volume fraction were determined on selected specimens. No influence of aluminium content was found below 0.08% on the as-rolled grain size in all steels studied. A low Al-V-steel produced the coarsest initial austenite grain size due to AlN dissolution at low temperatures leading to abnormal grain growth. An Al-free V-N steel had the finest initial microstructure. Although the as-rolled grain size for 20mm plate was similar in all steels tested, the grain distribution was relatively mixed. The final grain size in 6mm plate was similar for most compositions; the exception was an as-cast V low N steel, where the size of the second phase was inversely proportional to the sizing strain. This was attributed to both segregation and a low VN volume fraction available for effective pinning of austenite grain boundaries during cooling. Increasing the sizing strain refined the microstructure significantly in all steels.

Keywords: aluminium, grain size, nitrogen, reheating, sizing strain, steel, vanadium

Procedia PDF Downloads 124
36 Grain Growth Behavior of High Carbon Microalloyed Steels Containing Very Low Amounts of Niobium

Authors: Huseyin Zengin, Muhammet Emre Turan, Yunus Turen, Hayrettin Ahlatci, Yavuz Sun

Abstract:

This study aimed for understanding the effects of dilute Nb additions on the austenite microstructure of microalloyed steels at five different reheating temperatures from 950 °C to 1300 °C. Four microalloyed high-carbon steels having 0.8 %wt C were examined in which three of them had varying Nb concentrations from 0.005 wt% to 0.02 wt% and one of them had no Nb concentration. The quantitative metallographic techniques were used to measure the average prior austenite grain size in order to compare the grain growth pinning effects of Nb precipitates as a function of reheating temperature. Due to the higher stability of the precipitates with increasing Nb concentrations, the grain coarsening temperature that resulted in inefficient grain growth impediment and a bimodal grain distribution in the microstructure, showed an increase with increasing Nb concentration. The respective grain coarsening temperatures (T_GC) in an ascending order for the steels having 0.005 wt% Nb, 0.01 wt% Nb and 0.02 wt% Nb were 950 °C, 1050 °C and 1150 °C. According to these observed grain coarsening temperatures, an approximation was made considering the complete dissolution temperature (T_DISS) of second phase particles as T_GC=T_DISS-300. On the other hand, the plain carbon steel did not show abnormal grain growth behaviour due to the absence of second phase particles. It was also observed that the higher the Nb concentration, the smaller the average prior austenite grain size although the small increments in Nb concenration did not change the average grain size considerably.

Keywords: microalloyed steels, prior austenite grains, second phase particles, grain coarsening temperature

Procedia PDF Downloads 240
35 Strategy and Maze Surgery (Atrial fibrillation Surgery)

Authors: Shirin Jalili, Ramin Ghasemi Shayan

Abstract:

Atrial fibrillation is the foremost common arrhythmia around the world, with expanding recurrence famous with age. Thromboembolic occasions and strokes are the number one cause of mortality and morbidity. For patients who don't react to restorative treatment for rate and beat control, the maze method offers an elective treatment mediation. pharmaco-medical treatment for atrial fibrillation is pointed at the control of rate or cadence, intrusive treatment for atrial fibrillation is pointed at cadence control. An obtrusive approach may comprise of percutaneous catheter treatment, surgery, or a crossover approach. Since the maze method is recognized as the foremost successful way to dispense with AF, combining the maze strategy amid major cardiac surgeries has been received in clinical hone. the maze strategy, moreover known as Cox¬maze iii or the ‘cut¬and¬sew’ method, involves making different incisions within the atria to make an arrangement of scars that dispose of each potential zone of re¬entry. The electrical drive is constrained through a maze of scars that coordinates the electrical drive from the sinus node to the av node. By settling the headstrong period between ranges of scar, re¬entry is disposed of. in this article, we evaluate the Maze surgery method that's the surgical method of choice for the treatment of restorative atrial fibrillation.

Keywords: atrial fibrillation, congenital heart disease, procedure, maze surgery, treatment

Procedia PDF Downloads 122
34 Characteristics of Patients Undergoing Subclavian Artery Revascularization in Latvia: A Retrospective Analysis

Authors: Majid Shahbazi

Abstract:

Subclavian artery stenosis (SAS) is a common vascular disease that can cause a range of symptoms, from arm fatigue and weakness to ischemic stroke. Revascularization procedures, such as percutaneous transluminal angioplasty and stenting, are widely used to treat SAS and improve blood flow to the affected arm. However, the optimal management of patients with SAS is still unclear, and further research is needed to evaluate the safety and efficacy of different treatment options. This study aims to investigate the characteristics of patients with SAS who underwent revascularization procedures in Latvia (Specifically RAKUS). The research part of this paper aims to describe and analyze the demographics, comorbidities, diagnostic methods, types of revascularization procedures, and antiaggregant therapy used. The goal of this study is to provide insights into the current clinical practice in Latvia and help future treatment decision-makers. To achieve this aim, a retrospective study of 76 patients with SAS who underwent revascularization procedures was performed. After statistical analysis of the data, the study provided insights into the characteristics and management of patients with SAS in Latvia, highlighting the most observed comorbidities in these patients, the preferred diagnostic methods, and the most performed procedures. These findings can inform clinical decision-making and may have implications for the management of patients with subclavian artery stenosis in Latvia.

Keywords: subclavian artery stenosis, revascularization, characteristics of patients, comorbidities, retrospective analysis

Procedia PDF Downloads 76
33 Delamination Fracture Toughness Benefits of Inter-Woven Plies in Composite Laminates Produced through Automated Fibre Placement

Authors: Jayden Levy, Garth M. K. Pearce

Abstract:

An automated fibre placement method has been developed to build through-thickness reinforcement into carbon fibre reinforced plastic laminates during their production, with the goal of increasing delamination fracture toughness while circumventing the additional costs and defects imposed by post-layup stitching and z-pinning. Termed ‘inter-weaving’, the method uses custom placement sequences of thermoset prepreg tows to distribute regular fibre link regions in traditionally clean ply interfaces. Inter-weaving’s impact on mode I delamination fracture toughness was evaluated experimentally through double cantilever beam tests (ASTM standard D5528-13) on [±15°]9 laminates made from Park Electrochemical Corp. E-752-LT 1/4” carbon fibre prepreg tape. Unwoven and inter-woven automated fibre placement samples were compared to those of traditional laminates produced from standard uni-directional plies of the same material system. Unwoven automated fibre placement laminates were found to suffer a mostly constant 3.5% decrease in mode I delamination fracture toughness compared to flat uni-directional plies. Inter-weaving caused significant local fracture toughness increases (up to 50%), though these were offset by a matching overall reduction. These positive and negative behaviours of inter-woven laminates were respectively found to be caused by fibre breakage and matrix deformation at inter-weave sites, and the 3D layering of inter-woven ply interfaces providing numerous paths of least resistance for crack propagation.

Keywords: AFP, automated fibre placement, delamination, fracture toughness, inter-weaving

Procedia PDF Downloads 167
32 Using Audit Tools to Maintain Data Quality for ACC/NCDR PCI Registry Abstraction

Authors: Vikrum Malhotra, Manpreet Kaur, Ayesha Ghotto

Abstract:

Background: Cardiac registries such as ACC Percutaneous Coronary Intervention Registry require high quality data to be abstracted, including data elements such as nuclear cardiology, diagnostic coronary angiography, and PCI. Introduction: The audit tool created is used by data abstractors to provide data audits and assess the accuracy and inter-rater reliability of abstraction performed by the abstractors for a health system. This audit tool solution has been developed across 13 registries, including ACC/NCDR registries, PCI, STS, Get with the Guidelines. Methodology: The data audit tool was used to audit internal registry abstraction for all data elements, including stress test performed, type of stress test, data of stress test, results of stress test, risk/extent of ischemia, diagnostic catheterization detail, and PCI data elements for ACC/NCDR PCI registries. This is being used across 20 hospital systems internally and providing abstraction and audit services for them. Results: The data audit tool had inter-rater reliability and accuracy greater than 95% data accuracy and IRR score for the PCI registry in 50 PCI registry cases in 2021. Conclusion: The tool is being used internally for surgical societies and across hospital systems. The audit tool enables the abstractor to be assessed by an external abstractor and includes all of the data dictionary fields for each registry.

Keywords: abstraction, cardiac registry, cardiovascular registry, registry, data

Procedia PDF Downloads 83
31 Prospective Randomized Trial of Na/K Citrate for the Prevention of Contrast-Induced Nephropathy in High-Risk Patients

Authors: Leili Iranirad, Mohammad Saleh Sadeghi, Seyed Fakhreddin Hejazi, Negar Vakili Razlighi

Abstract:

Objective: Contrast-induced nephropathy (CIN) or contrast-induced acute kidney injury (CI-AKI) is an unknown acute kidney injury (AKI) occurring after exposure to contrast media (CM). Contrast agents are most often used for diagnostic procedures or therapeutic angiographic interventions. Recently, Na/K citrate as a urine alkalinization has been evaluated for the prevention of CIN. We conducted this experiment to evaluate the efficiency of Na/K citrate on CIN in high-risk patients treated with cardiac catheterization. Methods: A prospective randomized clinical trial was conducted on 400 patients having moderate to high-risk factors for CIN treated with elective percutaneous coronary intervention (PCI) and were assigned randomly to the control group or the Na/K citrate group. The Na/K citrate group (n=200) received 5 g Na/K citrate solution, which was diluted in 200 mL water two h before and four hours after the first administration and intravenous hydration for two h prior to and six h after the procedure, while the control group (n=200) only received intravenous hydration. Serum creatinine (SCr) was calculated prior to the contrast exposure and after 48 h. CIN was described as a 25% increase in creatinine of serum (SCr) or >0.5 mg/dl 48 h after contrast administration. Results: CIN was observed in 33 patients (16.5%) in the control group and in 6 patients (3%) in the Na/K citrate group. A significant variation was recorded in the CIN incidence between the two groups 48 h after the radiocontrast agent administration (p < 0.001). Conclusion: Our results show that Na/K citrate is useful and substantially reduces the incidence of CIN.

Keywords: contrast media, citrate, PCI

Procedia PDF Downloads 70
30 Useful Characteristics of Pleurotus Mushroom Hybrids

Authors: Suvalux Chaichuchote, Ratchadaporn Thonghem

Abstract:

Pleurotus mushroom is one of popular edible mushrooms in Thailand. It is much favored by consumers due to its delicious taste and high nutrition. It is commonly used as an ingredient in several dishes. The commercially cultivated strain grown in most farms is the Pleurotus sp., Hed Bhutan, that is widely distributed to mushroom farms throughout the country and can be cultivated almost all year round. However, it demands different cultivated strains from mushroom growers, therefore, the improving mushroom strains should be done to their benefits. In this study, we used a di-mon mating method to hybrid production from Hed Bhutan (P-3) as dikaryon material and monokaryotic mycelium were isolated from basidiospores of other three Pleurotus sp. by single spore isolation. The 3 hybrids: P-3XSA-6, P-3XSB-24 and P-3XSE-5 were recognized from the 12 hybridized successfully. They were appropriate hybridized in terms of fruiting body performance in the three time cycles of cultivation such as the number of days until growing, time for pinning, color and shape of fruiting bodies and yield. For genetic study, genomic DNAs of both Hed Bhutan (P-3) and three hybrids were extracted. A couple of primer ITS1 and ITS4 were used to amplify the gene coding for ITS1, ITS2 and 5.8S rRNA. The similarities between these amplified genes and databases of DNA revealed that Hed Bhutan (P-3) was the Pleurotus pulmonarius as well as P-3XSA-6, P-3XSB-24 and P-3XSE-5 hybrids. Furthermore, Hed Bhutan (P3) and three hybrids were distributed to 3 small-scale farms, with mushroom farming experience, in the countryside. To address this, one hundred and twenty mushroom bags of each strain were supplied to them. The findings, by interview, indicated two mushroom farmers were satisfied with P-3XSA-6 hybrid and P-3XSB-24 hybrid, thanks to their simultaneous fruiting time and good yield. While the other was satisfied with P-3XSB-24 hybrid due to its good yield and P-3XSE-5 hybrids thanks to its gradually fruiting body, benefiting in frequent harvest. Overall, farmers adopted all hybrids to grow as commercially cultivated strains as well as Hed Bhutan (P-3) strain.

Keywords: dikaryon, monokaryon, pleurotus, strain improvement

Procedia PDF Downloads 231
29 Thermomechanical Deformation Response in Cold Sprayed SiCp/Al Composites: Strengthening, Microstructure Characterization, and Thermomechanical Properties

Authors: L. Gyansah, Yanfang Shen, Jiqiang Wang, Tianying Xiong

Abstract:

SiCₚ/ pure Al composites with different SiC fractions (20 wt %, 30 wt %, and 40 wt %) were precisely cold sprayed, followed by hot axial-compression tests at deformation temperatures of 473 K to 673 K, leading to failure of specimens through routine crack propagation in their multiphase. The plastic deformation behaviour with respect to the SiCₚ contents and the deformation temperatures were studied at strain rate 1s-1.As-sprayed and post-failure specimens were analyzed by X-ray computed tomography (XCT), transmission electron microscopy (TEM), and scanning electron microscopy (SEM). Quasi-static thermomechanical testing results revealed that compressive strength (UTS = 228 MPa and 30.4 %) was the highest in the composites that was thermomechanically compressed at 473 K compared to those of the as-sprayed, while the as-sprayed exhibited a compressive strength of 182.8 MPa related to the increment in SiC fraction. Strength—plasticity synergy was promoted by dynamic recrystallization (DRX) through strengthening and refinement of the grains. The DRX degree depends relevantly on retainment of the uniformly ultrafine SiCₚ particulates, the pinning effects of the interfaces promoted by the ultrafine grain structures (UFG), and the higher deformation temperature. Reconstructed X-ray computed tomography data revealed different crack propagation mechanisms. A single-plane shear crack with multi-laminates fracture morphology yields relatively through the as-sprayed and as-deformed at 473 K deposits, while a multiphase plane shear cracks preeminently existed in high temperature deformed deposits resulting in multiphase-interface delaminations. Three pertinent strengthening mechanisms, videlicet, SiCp dispersed strengthening, refined grain strengthening, and dislocation strengthening, existed in the gradient microstructure, and their detailed contributions to the thermomechanical properties were discussed.

Keywords: cold spraying, hot deformation, deformation temperature, thermomechancal properties, SiC/Al composite

Procedia PDF Downloads 83
28 Ultrasound Guided Treatment of Carpal Tunnel Syndrome

Authors: Kazem Shakouri, Alireza Pishgahi, Homayoun Sadeghi-bBazargani, Shahla Dareshiri

Abstract:

Introduction: Carpal Tunnel Syndrome has numerous nonsurgical treatments including splint, physical therapy and corticosteroid injections. Aim: The purpose of this study was to evaluate the effectiveness of an ultrasound guided treatment procedure, for individuals with severe carpal tunnel syndrome. Materials and Method: 20 patients with an electrodiagnostic evidence of severe carpal tunnel syndrome were treated by an office-based ultrasound guided procedure (combination of percutaneous needle release of carpal tunnel and corticosteroid injection). Electrodiagnostic (nerve conduction study), clinical (Boston Carpal Tunnel Questionnaire, grip strength) and ultrasonic (median nerve and carpal tunnel cross-sectional area) measurements were recorded at baseline and one month after intervention. Results: Our preliminary data analysis showed that in one month follow up, patients had a significantly smaller cross-sectional area of the median nerve compared to pretreatment values (mean difference 0.06; 95%CI: 0.02-0.1; p < 0.001). In addition, patients had significantly less functional impairment (mean difference 35; 95% CI:28.7-43.4 ; p < 0.001), and an improved hand grip strength in one month follow up (mean difference 5.4; 95%CI: 3.1-7.8; p < 0.001;). There were no significant complications. Conclusion: Patients with severe carpal tunnel syndrome, who are candidates for surgical intervention, can consider office-based ultrasound guided needle release of carpal tunnel as an alternative safe treatment.

Keywords: Carpal Tunnel Syndrome, needle release, pain, ultrasound

Procedia PDF Downloads 223
27 Endoscopic Ultrasound-Guided Choledochoduodenostomy in an Advanced Extrahepatic Cholangiocarcinoma

Authors: Diego Carrasco, Catarina Freitas, Hugo Rio Tinto, Ricardo Rio Tinto, Nuno Couto, Joaquim Gago, Carlos Carvalho

Abstract:

Introduction: Endoscopic ultrasound-guided choledochoduodenostomy (EUS-CD) to drain the gallbladder can be a palliative care procedure for non-surgical oncologic patients with cholelithiasis and cholangitis process. Case description: A 59-years old Caucasian male diagnosed with extrahepatic cholangiocarcinoma with multiple liver, lung and peritoneum metastasis, unresponsive to treatment with gemcitabine/cisplatin, presented in the institution with fever, hypotension, and severe upper right abdominal pain secondary to cholelithiasis and cholangitis process. The patient was admitted and started on large spectrum antibiotics plus fluid-challenge. Afterward, a percutaneous transhepatic biliary drainage (PTBD) was performed to drain the gallbladder. This procedure temporarily stabilized the patient. However, the definitive solution required gallbladder removal. Since the patient exhibited an advanced oncologic disease and poor response to the chemotherapy, he was not a candidate for surgical intervention. Diagnostic Pathways: A self-expanding metal stent was placed from the duodenum into the bile duct by endoscopic ultrasound-guided. The stent allowed efficient drainage of the contrast from the gallbladder at the end of the endoscopic procedure. Conclusion and Discussion: The stent allowed efficient drainage of the contrast from the gallbladder at the end of the endoscopic procedure and successfully reversed the cholangitis process. EUS-CD is an effective and safe technique and can be used as a palliative care procedure for non-surgical oncologic patients.

Keywords: palliative care, cholangiocarcinoma, choledochoduodenostomy, endoscopic ultrasound-guided

Procedia PDF Downloads 160
26 Computed Tomography Guided Bone Biopsies: Experience at an Australian Metropolitan Hospital

Authors: K. Hinde, R. Bookun, P. Tran

Abstract:

Percutaneous CT guided biopsies provide a fast, minimally invasive, cost effective and safe method for obtaining tissue for histopathology and culture. Standards for diagnostic yield vary depending on whether the tissue is being obtained for histopathology or culture. We present a retrospective audit from Western Health in Melbourne Australia over a 12-month period which aimed to determine the diagnostic yield, technical success and complication rate for CT guided bone biopsies and identify factors affecting these results. The digital imaging storage program (Synapse Picture Archiving and Communication System – Fujifilm Australia) was analysed with key word searches from October 2015 to October 2016. Nineteen CT guided bone biopsies were performed during this time. The most common referring unit was oncology, work up imaging included CT, MRI, bone scan and PET scan. The complication rate was 0%, overall diagnostic yield was 74% with a technical success of 95%. When performing biopsies for histologic analysis diagnostic yield was 85% and when performing biopsies for bacterial culture diagnostic yield was 60%. There was no significant relationship identified between size of lesion, distance of lesion to skin, lesion appearance on CT, the number of samples taken or gauge of needle to diagnostic yield or technical success. CT guided bone biopsy at Western Health meets the standard reported at other major clinical centres for technical success and safety. It is a useful investigation in identification of primary malignancy in distal bone metastases.

Keywords: bone biopsy, computed tomography, core biopsy, histopathology

Procedia PDF Downloads 179
25 Endoscopic Treatment of Esophageal Injuries Using Vacuum Therapy

Authors: Murad Gasanov, Shagen Danielyan, Ali Gasanov, Yuri Teterin, Peter Yartsev

Abstract:

Background: Despite the advances made in modern surgery, the treatment of patients with esophageal injuries remains one of the most topical and complex issues. In recent years, high-technology minimally invasive methods, such as endoscopic vacuum therapy (EVT) in the treatment of esophageal injuries. The effectiveness of EVT has been sufficiently studied in case of failure of esophageal anastomoses, however the application of this method in case of mechanical esophageal injuries is limited by a small series of observations, indicating the necessity of additional study. Aim: The aim was to аnalyzed of own experience in the use of endoscopic vacuum therapy (EVT) in a comprehensive examination of patients with esophageal injuries. Methods: We analyzed the results of treatment of 24 patients with mechanical injuries of the esophagus for the period 2019-2021. Complex treatment of patients included the use of minimally invasive technologies, including percutaneous endoscopic gastrostomy (PEG), EVT and video-assisted thoracoscopic debridement. Evaluation of the effectiveness of treatment was carried out using multislice computed tomography (MSCT), endoscopy and laboratory tests. The duration of inpatient treatment and the duration of EVT, the number of system replacements, complications and mortality were taken into account. Result: EVT in patients with mechanical injuries of the esophagus allowed to achieve epithelialization of the esophageal defect in 21 patients (87.5%) in the form of linear scar on the site of perforation or pseudodiverticulum. Complications were noted in 4 patients (16.6%), including bleeding (2) and and esophageal stenosis in the perforation area (2). Lethal outcome was in one observation (4.2%). Conclusion. EVT may be the method of choice in complex treatment in patients with esophageal lesions.

Keywords: esophagus injuries, damage to the esophagus, perforation of the esophagus, spontaneous perforation of the esophagus, mediastinitis, endoscopic vacuum therapy

Procedia PDF Downloads 86
24 Quantification of Soft Tissue Artefacts Using Motion Capture Data and Ultrasound Depth Measurements

Authors: Azadeh Rouhandeh, Chris Joslin, Zhen Qu, Yuu Ono

Abstract:

The centre of rotation of the hip joint is needed for an accurate simulation of the joint performance in many applications such as pre-operative planning simulation, human gait analysis, and hip joint disorders. In human movement analysis, the hip joint center can be estimated using a functional method based on the relative motion of the femur to pelvis measured using reflective markers attached to the skin surface. The principal source of errors in estimation of hip joint centre location using functional methods is soft tissue artefacts due to the relative motion between the markers and bone. One of the main objectives in human movement analysis is the assessment of soft tissue artefact as the accuracy of functional methods depends upon it. Various studies have described the movement of soft tissue artefact invasively, such as intra-cortical pins, external fixators, percutaneous skeletal trackers, and Roentgen photogrammetry. The goal of this study is to present a non-invasive method to assess the displacements of the markers relative to the underlying bone using optical motion capture data and tissue thickness from ultrasound measurements during flexion, extension, and abduction (all with knee extended) of the hip joint. Results show that the artefact skin marker displacements are non-linear and larger in areas closer to the hip joint. Also marker displacements are dependent on the movement type and relatively larger in abduction movement. The quantification of soft tissue artefacts can be used as a basis for a correction procedure for hip joint kinematics.

Keywords: hip joint center, motion capture, soft tissue artefact, ultrasound depth measurement

Procedia PDF Downloads 258
23 Environmental, Social and Corporate Governance Reporting With Regard to Best Practices of Companies Listed on the Warsaw Stock Exchange - Selected Problems

Authors: Katarzyna Olejko

Abstract:

The need to redefine the goals and adapt the operational activities carried out in accordance with the concept of sustainable management to these goals results in the increasing importance of information on the company's activities perceived from the perspective of the effectiveness and efficiency of environmental goals implementation. The narrow scope of reporting data on a company's impact on the environment is not adequate to meet the information needs of modern investors. Reporting obligations are therefore imposed on companies in order to increase the effectiveness of corporate governance and to improve the process of assessing the achievement of environmental goals. The non-financial reporting obligations introduced in Polish legislation increased the scope of reported information. However, the lack of detailed guidelines on the method of reporting resulted in a large diversification of the scope of non-financial information, making it impossible to compare the data presented by companies. The source of information regarding the level of the implementation of standards in Environmental, social and corporate governance (ESG) is the report on compliance with best practices published by the Warsaw Stock Exchange. The document Best Practices of Warsaw Stock Exchange (WSE) Listed Companies (2021), amended by the WSE in 2021, includes the rules applicable to this area (ESG). The aim of this article is to present the level of compliance with good practices in the area of ESG by selected companies listed on the Warsaw Stock Exchange The research carried out as part of this study, which was based on information from reports on the compliance with good practices of companies listed on the Warsaw Stock Exchange that was made available in the good practice scanner, have revealed that good practices in the ESG area are implemented by companies to a limited extent. The level of their application in comparison with other rules is definitely lower. The lack of experience and clear guidelines on ESG reporting may cause some confusion, which is why conscious investors and reporting companies themselves are pinning their hopes on the Corporate Sustainability Reporting Directive (CSRD) adopted by European Parliament.

Keywords: reporting, ESG, corporate governance, best practices

Procedia PDF Downloads 55
22 Predictors and 3-Year Outcomes of Compromised Left Circumflex Coronary Artery After Left Main Crossover Stenting

Authors: Hameed Ullah, Karim Elakabawi, Han KE, Najeeb Ullah, Habib Ullah, Sardar Ali Shah, Hamad Haider Khan, Muhammad Asad Khan, Ning Guo, Zuyi Yuan

Abstract:

Background: Predictors of decreased fractional flow reserve at left circumflex coronary artery after left main (LM) crossover stenting are still lacking. The objectives of the present study were to provide the predictors for low Fractional flow reserve (FFR) at coronary artery (LCx) and the possible treatment strategies for the compromised LCx-together with their long term outcomes. Methods: A total of 563 included patients out of 1974 patients admitted to our hospital from February 2015 to November 2020 with significant distal LM-bifurcation lesions. The enrolled patients underwent single-stent cross-over PCI under IVUS guidance with further LCx intervention as indicated by measured FFR. Results: The included patients showed angiographic significant LCx ostial affection after LM-stenting, but only 116 (20.6%) patients had FFR <0.8. The 3-year composite MACE rates were comparable between the high and low FFR groups (16.8% vs. 15.5%, respectively; P=0.744). In a multivariable analysis, a low FFR in the LCx was associated with post-stenting MLA of the LCx (OR: 0.032, P <0.001), post-stenting LCx-plaque burden (OR: 1.166, P <0.001), post-stenting LM-MLA (OR: 0.821, P =0.038) and pre-stenting LCx-MLA (OR: 0.371, P =0.044). In patients with low FFR, management of compromised LCx with DEB had the lowest 3-year MACE rate (8.1%) as compared to either KBI (17.5%) or stenting group (20.5%), P =0.299. Conclusion: FFR-guided LCx intervention can avoid unnecessary LCx intervention. The post-stenting predictors of low FFR include post-stenting MLA and plaque burden of the LCx and MV stent length. The 3-year MACE rates were comparable between high FFR patients and patients who had low FFR and were adequately managed.

Keywords: fractional flow reserve, left main stem, percutaneous coronary interventions, intravascular ultrasound

Procedia PDF Downloads 20
21 Processing and Characterization of Oxide Dispersion Strengthened (ODS) Fe-14Cr-3W-0.5Ti-0.3Y₂O₃ (14YWT) Ferritic Steel

Authors: Farha Mizana Shamsudin, Shahidan Radiman, Yusof Abdullah, Nasri Abdul Hamid

Abstract:

Oxide dispersion strengthened (ODS) ferritic steels are amongst the most promising candidates for large scale structural materials to be applied in next generation fission and fusion nuclear power reactors. This kind of material is relatively stable at high temperature, possess remarkable mechanical properties and comparatively good resistance from neutron radiation damage. The superior performance of ODS ferritic steels over their conventional properties is attributed to the high number density of nano-sized dispersoids that act as nucleation sites and stable sinks for many small helium bubbles resulting from irradiation, and also as pinning points to dislocation movement and grain growth. ODS ferritic steels are usually produced by powder metallurgical routes involving mechanical alloying (MA) process of Y2O3 and pre-alloyed or elemental metallic powders, and then consolidated by hot isostatic pressing (HIP) or hot extrusion (HE) techniques. In this study, Fe-14Cr-3W-0.5Ti-0.3Y₂O₃ (designated as 14YWT) was produced by mechanical alloying process and followed by hot isostatic pressing (HIP) technique. Crystal structure and morphology of this sample were identified and characterized by using X-ray Diffraction (XRD) and field emission scanning electron microscope (FESEM) respectively. The magnetic measurement of this sample at room temperature was carried out by using a vibrating sample magnetometer (VSM). FESEM micrograph revealed a homogeneous microstructure constituted by fine grains of less than 650 nm in size. The ultra-fine dispersoids of size between 5 nm to 19 nm were observed homogeneously distributed within the BCC matrix. The EDS mapping reveals that the dispersoids contain Y-Ti-O nanoclusters and from the magnetization curve plotted by VSM, this sample approaches the behavior of soft ferromagnetic materials. In conclusion, ODS Fe-14Cr-3W-0.5Ti-0.3Y₂O₃ (14YWT) ferritic steel was successfully produced by HIP technique in this present study.

Keywords: hot isostatic pressing, magnetization, microstructure, ODS ferritic steel

Procedia PDF Downloads 295
20 Improved Non-Ideal Effects in AlGaN/GaN-Based Ion-Sensitive Field-Effect Transistors

Authors: Wei-Chou Hsu, Ching-Sung Lee, Han-Yin Liu

Abstract:

This work uses H2O2 oxidation technique to improve the pH sensitivity of the AlGaN/GaN-based ion-sensitive field-effect transistors (ISFETs). 10-nm-thick Al2O3 was grown on the surface of the AlGaN. It was found that the pH sensitivity was improved from 41.6 mV/pH to 55.2 mV/pH. Since the H2O2-grown Al2O3 was served as a passivation layer and the problem of Fermi-level pinning was suppressed for the ISFET with the H2O2 oxidation process. Hysteresis effect in the ISFET with the H2O2 treatment also became insignificant. The hysteresis effect was observed by dipping the ISFETs into different pH value solutions and comparing the voltage difference between the initial and final conditions. The hysteresis voltage (Vhys) of the ISFET with the H2O2 oxidation process was improved from 8.7 mV to 4.8 mV. The hysteresis effect is related to the buried binding sites which are related to the material defects like threading dislocations in the AlGaN/GaN heterostructure which was grown by the hetero-epitaxy technique. The H2O2-grown Al2O3 passivate these material defects and the Al2O3 has less material defects. The long-term stability of the ISFET is estimated by the drift effect measurement. The drift measurement was conducted by dipping the ISFETs into a specific pH value solution for 12 hours and the ISFETs were operating at a specific quiescent point. The drift rate is estimated by the drift voltage divided by the total measuring time. It was found that the drift rate of the ISFET was improved from 10.1 mV/hour to 1.91 mV/hour in the pH 7 solution, from 14.06 mV/hour to 6.38 mV/pH in the pH 2 solution, and from 12.8 mV/hour to 5.48 mV/hour in the pH 12 solution. The drift effect results from the capacitance variation in the electric double layer. The H2O2-grown Al2O3 provides an additional capacitance connection in series with the electric double layer. Therefore, the capacitance variation of the electric double layer became insignificant. Generally, the H2O2 oxidation process is a simple, fast, and cost-effective method for the AlGaN/GaN-based ISFET. Furthermore, the performance of the AlGaN/GaN ISFET was improved effectively and the non-ideal effects were suppressed.

Keywords: AlGaN/GaN, Al2O3, hysteresis effect, drift effect, reliability, passivation, pH sensors

Procedia PDF Downloads 300