Search results for: stenting
Commenced in January 2007
Frequency: Monthly
Edition: International
Paper Count: 18

Search results for: stenting

18 Post Coronary Artery Stenting Reflighting: Need for Change in Policy with Changing Antiplatelet Therapy

Authors: Keshavamurthy Ganapathy Bhat, Manvinderpal Singh Marwaha

Abstract:

Background: Coronary artery Disease (CAD) is a common cause of morbidity, mortality and reason for unfitness amongst aircrew. Coronary angioplasty and stenting are the standard of care for CAD. Antiplatelet drugs like Aspirin and Clopidogrel(Dual Antiplatelet therapy) are routinely prescribed post-stenting which are permitted for flying. However, in the recent past, Ticagrelor is being used in place of Clopidogrel as per ACC AHA and ESC guidelines. However Ticagrelor is not permitted for flying. Case Presentation: A 55-year-old pilot suffered Anterior Wall Myocardial Infarction. Angiography showed blockages in Left Anterior Descending Artery(LAD) and Right coronary artery (RCA). He underwent primary angioplasty and stenting LAD and subsequent stenting to RCA. Recovery was uneventful. One year later he was asymptomatic with normal Left ventricular function and no reversible perfusion defect on stress MPI. He had patent stents and coronaries on check angiogram. However, he was not allowed to fly since he was on Ticagrelor. He had to be switched over to Clopidogrel from Ticagrelor one year after stenting to permit him for flying. Similarly, switching had to be done in a 45-year-old pilot. Ticagrelor has been proven to be more effective than clopidogrel and as safe as Clopidogrel in preventing stent thrombosis. If Clopidogrel is being permitted, there is no need to restrict Ticagrelor. Hence "Policy" needs to be changed. Conclusions: Dual Antiplatelet therapy is the standard of care post coronary stenting which has been proved safe and effective. Policy needs to be changed to permit flying with Ticagrelor which is more effective than Clopidogrel and equally safe.

Keywords: antiplatelet drugs, coronary artery disease, stenting, ticagrelor

Procedia PDF Downloads 139
17 Endoscopic Stenting of the Main Pancreatic Duct in Patients With Pancreatic Fluid Collections After Pancreas Transplantation

Authors: Y. Teterin, S. Suleymanova, I. Dmitriev, P. Yartcev

Abstract:

Introduction: One of the most common complications after pancreas transplantation are pancreatic fluid collections (PFCs), which are often complicated not only by infection and subsequent disfunction of the pancreatoduodenal graft (PDG), but also with a rather high mortality rate of recipients. Drainage is not always effective and often requires repeated open surgical interventions, which worsens the outcome of the surgery. Percutaneous drainage of PFCs combined with endoscopic stenting of the main pancreatic duct of the pancreatoduodenal graft (MPDPDG) showed high efficiency in the treatment of PFCs. Aims & Methods: From 01.01.2012 to 31.12.2021 at the Sklifosovsky Research Institute for Emergency Medicine were performed 64 transplantations of PDG. In 11 cases (17.2%), the early postoperative period was complicated by the formation of PFCs. Of these, 7 patients underwent percutaneous drainage of pancreonecrosis with high efficiency and did not required additional methods of treatment. In the remaining 4 patients, drainage was ineffective and was an indication for endoscopic stenting of the MPDPDG. They were the ones who made up the study group. Among them were 3 men and 1 woman. The mean age of the patients was 36,4 years.PFCs in these patients formed on days 1, 12, 18, and 47 after PDG transplantation. We used a gastroscope to stent the MPDPDG, due to anatomical features of the location of the duodenoduodenal anastomosis after PDG transplantation. Through the endoscope channel was performed selective catheterization of the MPDPDG, using a catheter and a guidewire, followed by its contrasting with a water-soluble contrast agent. Due to the extravasation of the contrast, was determined the localization of the defect in the PDG duct system. After that, a plastic pancreatic stent with a diameter of 7 Fr. and a length of 7 cm. was installed along guidewire. The stent was installed in such a way that its proximal edge completely covered the defect zone, and the distal one was determined in the intestinal lumen. Results: In all patients PDG pancreaticography revealed extravasation of a contrast in the area of the isthmus and body of the pancreas, which required stenting of the MPDPDG. In 1 (25%) case, the patient had a dislocation of the stent into the intestinal lumen (III degree according to Clavien-Dindo (2009)). This patient underwent repeated endoscopic stenting of the MPDPDG. On average 23 days after endoscopic stenting of the MPDPDG, the drainage tubes were removed and after approximately 40 days all patients were discharged in a satisfactory condition with follow-up endocrinologist and surgeon consultation. Pancreatic stents were removed after 6 months ± 7 days. Conclusion: Endoscopic stenting of the main pancreatic duct of the donor pancreas is by far the most highly effective and minimally invasive method in the treatment of PFCs after transplantation of the pancreatoduodenal complex.

Keywords: pancreas transplantation, endoscopy surgery, diabetes, stenting, main pancreatic duct

Procedia PDF Downloads 56
16 Long-Term Results of Coronary Bifurcation Stenting with Drug Eluting Stents

Authors: Piotr Muzyk, Beata Morawiec, Mariusz Opara, Andrzej Tomasik, Brygida Przywara-Chowaniec, Wojciech Jachec, Ewa Nowalany-Kozielska, Damian Kawecki

Abstract:

Background: Coronary bifurcation is one of the most complex lesion in patients with coronary ar-tery disease. Provisional T-stenting is currently one of the recommended techniques. The aim was to assess optimal methods of treatment in the era of drug-eluting stents (DES). Methods: The regis-try consisted of data from 1916 patients treated with coronary percutaneous interventions (PCI) using either first- or second-generation DES. Patients with bifurcation lesion entered the analysis. Major adverse cardiac and cardiovascular events (MACCE) were assessed at one year of follow-up and comprised of death, acute myocardial infarction (AMI), repeated PCI (re-PCI) of target ves-sel and stroke. Results: Of 1916 registry patients, 204 patients (11%) were diagnosed with bifurcation lesion >50% and entered the analysis. The most commonly used technique was provi-sional T-stenting (141 patients, 69%). Optimization with kissing-balloons technique was performed in 45 patients (22%). In 59 patients (29%) second-generation DES was implanted, while in 112 pa-tients (55%), first-generation DES was used. In 33 patients (16%) both types of DES were used. The procedure success rate (TIMI 3 flow) was achieved in 98% of patients. In one-year follow-up, there were 39 MACCE (19%) (9 deaths, 17 AMI, 16 re-PCI and 5 strokes). Provisional T-stenting resulted in similar rate of MACCE to other techniques (16% vs. 5%, p=0.27) and similar occurrence of re-PCI (6% vs. 2%, p=0.78). The results of post-PCI kissing-balloon technique gave equal out-comes with 3% vs. 16% of MACCE in patients in whom no optimization technique was used (p=0.39). The type of implanted DES (second- vs. first-generation) had no influence on MACCE (4% vs 14%, respectively, p=0.12) and re-PCI (1.7% vs. 51% patients, respectively, p=0.28). Con-clusions: The treatment of bifurcation lesions with PCI represent high-risk procedures with high rate of MACCE. Stenting technique, optimization of PCI and the generation of implanted stent should be personalized for each case to balance risk of the procedure. In this setting, the operator experience might be the factor of better outcome, which should be further investigated.

Keywords: coronary bifurcation, drug eluting stents, long-term follow-up, percutaneous coronary interventions

Procedia PDF Downloads 170
15 Tracheal Stenting to Relieve Respiratory Distress in Patient with Advanced Esophageal Malignancy and Its Anaesthetic Management

Authors: Aarti Agarwal, Ajmal Khan

Abstract:

Background and Objective: Breathing difficulty is most distressing symptom for the patient and their caregivers providing palliative care to individuals with advanced malignancy. It needs to be tackled effectively and sometimes preemptively to provide relief from respiratory obstruction. Interventional procedures like tracheal stenting are becoming increasingly popular as a part of palliation for respiratory symptoms. We present a case of esophageal tumor earlier stented by Gastroenterologist to maintain esophageal patency, but the tumor outgrew to produce tracheal infiltration and thereby causing airway obstruction. Method and Result: 62-year-old man presented with unresectable Carcinoma oesophagus with inability to swallow. A metallic stent was placed by the gastroenterologist, to maintain esophageal patency and enable patient to swallow. Two months later, the patient returned to hospital in emergency with respiratory distress. CT neck and thorax revealed tumor infiltration through posterior tracheal wall. Lower extent of the tumor was till 1 cm above the carina. Airway stenting with Tracheo bronchial stent with Y configuration was planned under general anaesthesia with airway blocks. Superior Laryngeal Nerve Block, Glossopharyngeal block and Trans tracheal infiltration of local anaesthetics were performed. The patient was sedated with Fentanyl, Midazolam and propofol infusion but was breathing spontaneously. Once the rigid bronchoscope was placed inside trachea, breathing was supported with oxygen and sevoflurane. Initially, the trachea was cleared of tumor by coring. After creating space, tracheal stent was positioned and deployed. After stent placement patient was awakened, suctioned and nebulized. His respiratory stridor relieved instantaneously and was shifted to recovery. Conclusion: Airway blocks help in decreasing the incidence and severity of coughing during airway instrumentation thereby help in proper stent placement. They also reduce the requirement of general anaesthetics and hasten the post stenting recovery. Airway stent provided immediate relief to patient from symptoms of respiratory difficulty. Decision for early tracheal stenting may be taken for a select group of patients with high propensity for local spread, thereby avoiding respiratory complications and providing better quality of life in patients with inoperable malignancy.

Keywords: tracheal stent, respiratory difficulty, esophageal tumor, anaesthetic management

Procedia PDF Downloads 190
14 A 30 Year Audit of the Vascular Complications of Ports: Permanent Intravascular Access Devices

Authors: S. Kershaw, P. J. Barry, K. Webb

Abstract:

Background: Cystic Fibrosis (CF) is a chronic lung disease where patients have chronic lung infection punctuated by acute exacerbations that require intermittent intravenous (IV) antibiotics during their lives. With time, peripheral venous access can become difficult and limited. Accessing these veins can become arduous, traumatic, painful and unworkable. A permanent intravascular access device or Port is a small device that is inserted into the central venous system that allows the delivery of medicine eliminating the need for peripheral venous access. Ports represent a convenient and efficient method when venous access is required on a permanent basis however they are also associated with significant vascular complications. Superior Vena Cava Obstruction (SVCO) is a rare but significant vascular complication of ports in this setting. Objective: We aimed to look at a single CF centre’s experience of port-related SVCO over a thirty year period. Methods: Retrospective data was extracted using patient’s notes, electronic radiological reports and local databases over a period in excess of 30 years from 1982 to 2014. Results: 13 patients were identified with SVCO as a result of their port. 11 patients had CF (9 female, 2 male), one male patient had Primary Ciliary Dyskinesia and one female patient had severe Asthma. The mean port function was 1532 days (range 110 – 4049) and the mean age at SVCO was 24 years (range 11.1 to 36.5 years). The most common symptoms were facial oedema (n=8, 61.5%) and dilated veins (n=6, 46.2%). 7 patients had their Ports removed after SVCO. 6 patients underwent attempted stenting (46.2%) and 6 did not. 4 out of the 6 who underwent stenting required/had re-intervention. 3 of the 6 patients who underwent stenting had symptom resolution, however, 4 of the 6 patients who were not stented had symptom resolution also. Symptom resolution was not guaranteed with stenting and required re-intervention in two-thirds. Conclusion: This case series represents the experience of one of the longest established CF units in the UK and represents the largest cohort ever reported in the literature.

Keywords: ports, Superior Vena Cava Obstruction, cystic fibrosis, access devices

Procedia PDF Downloads 293
13 Left Atrial Appendage Occlusion vs Oral Anticoagulants in Atrial Fibrillation and Coronary Stenting. The DESAFIO Registry

Authors: José Ramón López-Mínguez, Estrella Suárez-Corchuelo, Sergio López-Tejero, Luis Nombela-Franco, Xavier Freixa-Rofastes, Guillermo Bastos-Fernández, Xavier Millán-Álvarez, Raúl Moreno-Gómez, José Antonio Fernández-Díaz, Ignacio Amat-Santos, Tomás Benito-González, Fernando Alfonso-Manterola, Pablo Salinas-Sanguino, Pedro Cepas-Guillén, Dabit Arzamendi, Ignacio Cruz-González, Juan Manuel Nogales-Asensio

Abstract:

Background and objectives: The treatment of patients with non-valvular atrial fibrillation (NVAF) who need coronary stenting is challenging. The objective of the study was to determine whether left atrial appendage occlusion (LAAO) could be a feasible option and benefit these patients. To this end, we studied the impact of LAAO plus antiplatelet drugs vs oral anticoagulants (OAC) (including direct OAC) plus antiplatelet drugs in these patients’ long-term outcomes. Methods: The results of 207 consecutive patients with NVAF who underwent coronary stenting were analyzed. A total of 146 patients were treated with OAC (75 with acenocoumarol, 71 with direct OAC) while 61 underwent LAAO. The median follow-up was 35 months. Patients also received antiplatelet therapy as prescribed by their cardiologist. The study received the proper ethical oversight. Results: Age (mean 75.7 years), and the past medical history of stroke were similar in both groups. However, the LAAO group had more unfavorable characteristics (history of coronary artery disease [CHA2DS2-VASc], and significant bleeding [BARC ≥ 2] and HAS-BLED). The occurrence of major adverse events (death, stroke/transient ischemic events, major bleeding) and major cardiovascular events (cardiac death, stroke/transient ischemic attack, and myocardial infarction) were significantly higher in the OAC group compared to the LAAO group: 19.75% vs 9.06% (HR, 2.18; P = .008) and 6.37% vs 1.91% (HR, 3.34; P = .037), respectively. Conclusions: In patients with NVAF undergoing coronary stenting, LAAO plus antiplatelet therapy produced better long-term outcomes compared to treatment with OAC plus antiplatelet therapy despite the unfavorable baseline characteristics of the LAAO group.

Keywords: stents, atrial fibrillation, anticoagulants, left atrial appendage occlusion

Procedia PDF Downloads 20
12 Interventional Radiology Perception among Medical Students

Authors: Shujon Mohammed Alazzam, Sarah Saad Alamer, Omar Hassan Kasule, Lama Suliman Aleid, Mohammad Abdulaziz Alakeel, Boshra Mosleh Alanazi, Abdullah Abdulelah Altowairqi, Yahya Ali Al-Asiri

Abstract:

Background: Interventional radiology (IR) is a specialized field within radiology that diagnose and treat several conditions through a minimally invasive surgical procedure that involves the use of various radiological techniques. In the last few years, the role of IR has expanded to include a variety of organ systems which have been led to an increase in demand for these Specialties. The level of knowledge regarding IR is relatively low in general. In this study, we aimed to investigate the perceptions of interventional radiology (IR) as a specialty among medical students and medical interns in Riyadh, Saudi Arabia. Methodology: This study was a cross section. The target population is medical students in January 2023 in Riyadh city, KSA. We used the questionnaire for face-to-face interviews with voluntary participants to assess their knowledge of Interventional radiology. Permission was taken from participants to use their information. Assuring them that the data in this study was used only for scientific purposes. Results: According to the inclusion criteria, a total of 314 students participated in the study. (49%) of the participants were in the preclinical years, and (51%) were in the clinical years. The findings indicate more than half of the students think that they had good information about IR (58%), while (42%) reported that they had poor information and knowledge about IR. Only (28%) of students were planning to take an elective and radiology rotation, (and 27%) said they would consider a career in IR. (73%) of the participants who would not consider a career in IR, the highest reasons in order were due to "I do not find it interesting" (45%), then "Radiation exposure" (14%). Around half (48%) thought that an IRs must complete a residency training program in both radiology and surgery, and just (36%) of the students believe that an IRs must finish training in radiology. Our data show the procedures performed by IRs that (66%) lower limb angioplasty and stenting (58%) Cardiac angioplasty or stenting. (68%) of the students were familiar with angioplasty. When asked about the source of exposure to angioplasty, the majority (46%) were from a cardiologist, (and 16%) were from the interventional radiologist. Regarding IR career prospects, (78%) of the students believe that IRs have good career prospects. In conclusion, our findings reveal that the perception and exposure to IR among medical students and interns are generally poor. This has a direct influence on the student's decision regarding IR as a career path. Recommendations to attract medical students and promote IR as a career should be increased knowledge among medical students and future physicians through early exposure to IR, and this will promote the specialty's growth; also, involvement of the Saudi Interventional Radiology Society and Radiological Society of Saudi Arabia is essential.

Keywords: knowledge, medical students, perceptions, radiology, interventional radiology, Saudi Arabia

Procedia PDF Downloads 51
11 Finite Element Analysis of the Anaconda Device: Efficiently Predicting the Location and Shape of a Deployed Stent

Authors: Faidon Kyriakou, William Dempster, David Nash

Abstract:

Abdominal Aortic Aneurysm (AAA) is a major life-threatening pathology for which modern approaches reduce the need for open surgery through the use of stenting. The success of stenting though is sometimes jeopardized by the final position of the stent graft inside the human artery which may result in migration, endoleaks or blood flow occlusion. Herein, a finite element (FE) model of the commercial medical device AnacondaTM (Vascutek, Terumo) has been developed and validated in order to create a numerical tool able to provide useful clinical insight before the surgical procedure takes place. The AnacondaTM device consists of a series of NiTi rings sewn onto woven polyester fabric, a structure that despite its column stiffness is flexible enough to be used in very tortuous geometries. For the purposes of this study, a FE model of the device was built in Abaqus® (version 6.13-2) with the combination of beam, shell and surface elements; the choice of these building blocks was made to keep the computational cost to a minimum. The validation of the numerical model was performed by comparing the deployed position of a full stent graft device inside a constructed AAA with a duplicate set-up in Abaqus®. Specifically, an AAA geometry was built in CAD software and included regions of both high and low tortuosity. Subsequently, the CAD model was 3D printed into a transparent aneurysm, and a stent was deployed in the lab following the steps of the clinical procedure. Images on the frontal and sagittal planes of the experiment allowed the comparison with the results of the numerical model. By overlapping the experimental and computational images, the mean and maximum distances between the rings of the two models were measured in the longitudinal, and the transverse direction and, a 5mm upper bound was set as a limit commonly used by clinicians when working with simulations. The two models showed very good agreement of their spatial positioning, especially in the less tortuous regions. As a result, and despite the inherent uncertainties of a surgical procedure, the FE model allows confidence that the final position of the stent graft, when deployed in vivo, can also be predicted with significant accuracy. Moreover, the numerical model run in just a few hours, an encouraging result for applications in the clinical routine. In conclusion, the efficient modelling of a complicated structure which combines thin scaffolding and fabric has been demonstrated to be feasible. Furthermore, the prediction capabilities of the location of each stent ring, as well as the global shape of the graft, has been shown. This can allow surgeons to better plan their procedures and medical device manufacturers to optimize their designs. The current model can further be used as a starting point for patient specific CFD analysis.

Keywords: AAA, efficiency, finite element analysis, stent deployment

Procedia PDF Downloads 162
10 An Unusual Presentation of Uveal Melanoma

Authors: Natasha Goh, Sebastian Brown

Abstract:

Purpose: This case report describes an unusual presentation of uveal melanoma. Method: Case notes, imaging, and histopathological specimen were reviewed for this case report. Result: The patient is a 62-year-old lady of Chinese heritage who had been receiving follow-up at the eye clinic of a tertiary hospital. She had a longstanding history of poor vision in her right eye after sustaining trauma to the eye at age 3. She was found to have a carotid-cavernous sinus fistula in the right eye in 2009 and underwent stenting in China. Unfortunately, this was unsuccessful and resulted in a painful blind eye. She had represented with headaches, worsening eye pain, and ptosis in Sydney in 2016. Her CT angiogram showed a calcified vascular structure in the orbit and globe, and she was offered a digital subtraction angiography by the neurosurgical team, which she ultimately declined. She had since been followed up at the eye clinic for the pthisical eye. Due to chronic ocular pain and recurrent conjunctivitis, the decision was made for an evisceration in 2021. The specimen was sent for routine histopathological examination and returned positive for uveal melanoma. The patient was subsequently referred to a melanoma center for further follow-up, which comprised serial imaging and radiotherapy treatment. Conclusion: Clinicians should bear in mind that uveal melanomas may present in a longstanding phthisical eye and in patients with no or little apparent risk factors.

Keywords: uveal melanoma, pthisical eye, carotid cavernous fistula, uveal melanoma risk factors

Procedia PDF Downloads 49
9 Characteristics of Patients Undergoing Subclavian Artery Revascularization in Latvia: A Retrospective Analysis

Authors: Majid Shahbazi

Abstract:

Subclavian artery stenosis (SAS) is a common vascular disease that can cause a range of symptoms, from arm fatigue and weakness to ischemic stroke. Revascularization procedures, such as percutaneous transluminal angioplasty and stenting, are widely used to treat SAS and improve blood flow to the affected arm. However, the optimal management of patients with SAS is still unclear, and further research is needed to evaluate the safety and efficacy of different treatment options. This study aims to investigate the characteristics of patients with SAS who underwent revascularization procedures in Latvia (Specifically RAKUS). The research part of this paper aims to describe and analyze the demographics, comorbidities, diagnostic methods, types of revascularization procedures, and antiaggregant therapy used. The goal of this study is to provide insights into the current clinical practice in Latvia and help future treatment decision-makers. To achieve this aim, a retrospective study of 76 patients with SAS who underwent revascularization procedures was performed. After statistical analysis of the data, the study provided insights into the characteristics and management of patients with SAS in Latvia, highlighting the most observed comorbidities in these patients, the preferred diagnostic methods, and the most performed procedures. These findings can inform clinical decision-making and may have implications for the management of patients with subclavian artery stenosis in Latvia.

Keywords: subclavian artery stenosis, revascularization, characteristics of patients, comorbidities, retrospective analysis

Procedia PDF Downloads 60
8 Traumatic Brachiocephalic Artery Pseudoaneurysm

Authors: Sally Shepherd, Jessica Wong, David Read

Abstract:

Traumatic brachiocephalic artery aneurysm is a rare injury that typically occurs as a result of a blunt chest injury. A 19-year-old female sustained a head-on, high speed motor vehicle crash into a tree. Upon release after 45 minutes of entrapment, she was tachycardic but normotensive, with a significant seatbelt sign across her chest and open deformed right thigh with weak pulses in bilateral lower limbs. A chest XR showed mild upper mediastinal widening. A CT trauma series plus gated CT chest revealed a grade 3a aortic arch transection with brachiocephalic pseudoaneurysm. Endovascular repair of the brachiocephalic artery was attempted post-presentation but was unsuccessful as the first stent migrated to the infrarenal abdominal aorta and the second stent across the brachiocephalic artery origin had a persistent leak at the base. She was transferred to Intensive Care for strict blood pressure control. She returned to theatre 5 hours later for a median sternotomy, aortic arch repair with an 8mm graft extraction, and excision of the innominate artery pseudoaneurysm. She had an uncomplicated post-operative recovery. This case highlights that brachiocephalic artery injury is a rare but potentially lethal injury as a result of blunt chest trauma. Safe management requires a combined Vascular and Cardiothoracic team approach, as stenting alone may be insufficient.

Keywords: blunt chest injury, Brachiocephalic aneurysm, innominate artery, trauma

Procedia PDF Downloads 200
7 An Assessment of Finite Element Computations in the Structural Analysis of Diverse Coronary Stent Types: Identifying Prerequisites for Advancement

Authors: Amir Reza Heydari, Yaser Jenab

Abstract:

Coronary artery disease, a common cardiovascular disease, is attributed to the accumulation of cholesterol-based plaques in the coronary arteries, leading to atherosclerosis. This disease is associated with risk factors such as smoking, hypertension, diabetes, and elevated cholesterol levels, contributing to severe clinical consequences, including acute coronary syndromes and myocardial infarction. Treatment approaches such as from lifestyle interventions to surgical procedures like percutaneous coronary intervention and coronary artery bypass surgery. These interventions often employ stents, including bare-metal stents (BMS), drug-eluting stents (DES), and bioresorbable vascular scaffolds (BVS), each with its advantages and limitations. Computational tools have emerged as critical in optimizing stent designs and assessing their performance. The aim of this study is to provide an overview of the computational methods of studies based on the finite element (FE) method in the field of coronary stenting and discuss the potential for development and clinical application of stent devices. Additionally, the importance of assessing the ability of computational models is emphasized to represent real-world phenomena, supported by recent guidelines from the American Society of Mechanical Engineers (ASME). Validation processes proposed include comparing model performance with in vivo, ex-vivo, or in vitro data, alongside uncertainty quantification and sensitivity analysis. These methods can enhance the credibility and reliability of in silico simulations, ultimately aiding in the assessment of coronary stent designs in various clinical contexts.

Keywords: atherosclerosis, materials, restenosis, review, validation

Procedia PDF Downloads 42
6 The Effect of Stent Coating on the Stent Flexibility: Comparison of Covered Stent and Bare Metal Stent

Authors: Keping Zuo, Foad Kabinejadian, Gideon Praveen Kumar Vijayakumar, Fangsen Cui, Pei Ho, Hwa Liang Leo

Abstract:

Carotid artery stenting (CAS) is the standard procedure for patients with severe carotid stenosis at high risk for carotid endarterectomy (CAE). A major drawback of CAS is the higher incidence of procedure-related stroke compared with traditional open surgical treatment for carotid stenosis - CEA, even with the use of the embolic protection devices (EPD). As the currently available bare metal stents cannot address this problem, our research group developed a novel preferential covered-stent for carotid artery aims to prevent friable fragments of atherosclerotic plaques from flowing into the cerebral circulation, and yet maintaining the flow of the external carotid artery. The preliminary animal studies have demonstrated the potential of this novel covered-stent design for the treatment of carotid atherosclerotic stenosis. The purpose of this study is to evaluate the effect of membrane coating on the stent flexibility in order to improve the clinical performance of our novel covered stents. A total of 21 stents were evaluated in this study: 15 self expanding bare nitinol stents and 6 PTFE-covered stents. 10 of the bare stents were coated with 11%, 16% and 22% Polyurethane(PU), 4%, 6.25% and 11% EE, as well as 22% PU plus 5 μm Parylene. Different laser cutting designs were performed on 4 of the PTFE covert stents. All the stents, with or without the covered membrane, were subjected to a three-point flexural test. The stents were placed on two supports that are 30 mm apart, and the actuator is applying a force in the exact middle of the two supports with a loading pin with radius 2.5 mm. The loading pin displacement change, the force and the variation in stent shape were recorded for analysis. The flexibility of the stents was evaluated by the lumen area preservation at three displacement bending levels: 5mm, 7mm, and 10mm. All the lumen areas in all stents decreased with the increase of the displacement from 0 to 10 mm. The bare stents were able to maintain 0.864 ± 0.015, 0.740 ± 0.025 and 0.597 ± 0.031of original lumen area at 5 mm, 7 mm and 10mm displacement respectively. For covered stents, the stents with EE coating membrane showed the best lumen area preservation (0.839 ± 0.005, 0.7334 ± 0.043 and 0.559 ± 0.014), whereas, the stents with PU and Parylene coating were only 0.662, 0.439 and 0.305. Bending stiffness was also calculated and compared. These results provided optimal material information and it was crucial for enhancing clinical performance of our novel covered stents.

Keywords: carotid artery, covered stent, nonlinear, hyperelastic, stress, strain

Procedia PDF Downloads 268
5 Polyurethane Membrane Mechanical Property Study for a Novel Carotid Covered Stent

Authors: Keping Zuo, Jia Yin Chia, Gideon Praveen Kumar Vijayakumar, Foad Kabinejadian, Fangsen Cui, Pei Ho, Hwa Liang Leo

Abstract:

Carotid artery is the major vessel supplying blood to the brain. Carotid artery stenosis is one of the three major causes of stroke and the stroke is the fourth leading cause of death and the first leading cause of disability in most developed countries. Although there is an increasing interest in carotid artery stenting for treatment of cervical carotid artery bifurcation therosclerotic disease, currently available bare metal stents cannot provide an adequate protection against the detachment of the plaque fragments over diseased carotid artery, which could result in the formation of micro-emboli and subsequent stroke. Our research group has recently developed a novel preferential covered-stent for carotid artery aims to prevent friable fragments of atherosclerotic plaques from flowing into the cerebral circulation, and yet retaining the ability to preserve the flow of the external carotid artery. The preliminary animal studies have demonstrated the potential of this novel covered-stent design for the treatment of carotid therosclerotic stenosis. The purpose of this study is to evaluate the biomechanical property of PU membrane of different concentration configurations in order to refine the stent coating technique and enhance the clinical performance of our novel carotid covered stent. Results from this study also provide necessary material property information crucial for accurate simulation analysis for our stents. Method: Medical grade Polyurethane (ChronoFlex AR) was used to prepare PU membrane specimens. Different PU membrane configurations were subjected to uniaxial test: 22%, 16%, and 11% PU solution were made by mixing the original solution with proper amount of the Dimethylacetamide (DMAC). The specimens were then immersed in physiological saline solution for 24 hours before test. All specimens were moistened with saline solution before mounting and subsequent uniaxial testing. The specimens were preconditioned by loading the PU membrane sample to a peak stress of 5.5 Mpa for 10 consecutive cycles at a rate of 50 mm/min. The specimens were then stretched to failure at the same loading rate. Result: The results showed that the stress-strain response curves of all PU membrane samples exhibited nonlinear characteristic. For the ultimate failure stress, 22% PU membrane was significantly higher than 16% (p<0.05). In general, our preliminary results showed that lower concentration PU membrane is stiffer than the higher concentration one. From the perspective of mechanical properties, 22% PU membrane is a better choice for the covered stent. Interestingly, the hyperelastic Ogden model is able to accurately capture the nonlinear, isotropic stress-strain behavior of PU membrane with R2 of 0.9977 ± 0.00172. This result will be useful for future biomechanical analysis of our stent designs and will play an important role for computational modeling of our covered stent fatigue study.

Keywords: carotid artery, covered stent, nonlinear, hyperelastic, stress, strain

Procedia PDF Downloads 278
4 The Role of Intraluminal Endoscopy in the Diagnosis and Treatment of Fluid Collections in Patients With Acute Pancreatitis

Authors: A. Askerov, Y. Teterin, P. Yartcev, S. Novikov

Abstract:

Introduction: Acute pancreatitis (AP) is a socially significant problem for public health and continues to be one of the most common causes of hospitalization of patients with pathology of the gastrointestinal tract. It is characterized by high mortality rates, which reaches 62-65% in infected pancreatic necrosis. Aims & Methods: The study group included 63 patients who underwent transluminal drainage (TLD) fluid collection (FC). All patients were performed transabdominal ultrasound, computer tomography of the abdominal cavity and retroperitoneal organs and endoscopic ultrasound (EUS) of the pancreatobiliary zone. The EUS was used as a final diagnostic method to determine the characteristics of FC. The indications for TLD were: the distance between the wall of the hollow organ and the FC was not more than 1 cm, the absence of large vessels on the puncture trajectory (more than 3 mm), and the size of the formation was more than 5 cm. When a homogeneous cavity with clear, even contours was detected, a plastic stent with rounded ends (“double pig tail”) was installed. The indication for the installation of a fully covered self-expanding stent was the detection of nonhomogeneous anechoic FC with hyperechoic inclusions and cloudy purulent contents. In patients with necrotic forms after drainage of the purulent cavity, a cystonasal drainage with a diameter of 7Fr was installed in its lumen under X-ray control to sanitize the cavity with a 0.05% aqueous solution of chlorhexidine. Endoscopic necrectomy was performed every 24-48 hours. The plastic stent was removed in 6 month, the fully covered self-expanding stent - in 1 month after the patient was discharged from the hospital. Results: Endoscopic TLD was performed in 63 patients. The FC corresponding to interstitial edematous pancreatitis was detected in 39 (62%) patients who underwent TLD with the installation of a plastic stent with rounded ends. In 24 (38%) patients with necrotic forms of FC, a fully covered self-expanding stent was placed. Communication with the ductal system of the pancreas was found in 5 (7.9%) patients. They underwent pancreaticoduodenal stenting. A complicated postoperative period was noted in 4 (6.3%) cases and was manifested by bleeding from the zone of pancreatogenic destruction. In 2 (3.1%) cases, this required angiography and endovascular embolization a. gastroduodenalis, in 1 (1.6%) case, endoscopic hemostasis was performed by filling the cavity with 4 ml of Hemoblock hemostatic solution. The combination of both methods was used in 1 (1.6%) patient. There was no evidence of recurrent bleeding in these patients. Lethal outcome occurred in 4 patients (6.3%). In 3 (4.7%) patients, the cause of death was multiple organ failure, in 1 (1.6%) - severe nosocomial pneumonia that developed on the 32nd day after drainage. Conclusions: 1. EUS is not only the most important method for diagnosing FC in AP, but also allows you to determine further tactics for their intraluminal drainage.2. Endoscopic intraluminal drainage of fluid zones in 45.8% of cases is the final minimally invasive method of surgical treatment of large-focal pancreatic necrosis. Disclosure: Nothing to disclose.

Keywords: acute pancreatitis, fluid collection, endoscopy surgery, necrectomy, transluminal drainage

Procedia PDF Downloads 74
3 Non-Invasive Evaluation of Patients After Percutaneous Coronary Revascularization. The Role of Cardiac Imaging

Authors: Abdou Elhendy

Abstract:

Numerous study have shown the efficacy of the percutaneous intervention (PCI) and coronary stenting in improving left ventricular function and relieving exertional angina. Furthermore, PCI remains the main line of therapy in acute myocardial infarction. Improvement of procedural techniques and new devices have resulted in an increased number of PCI in those with difficult and extensive lesions, multivessel disease as well as total occlusion. Immediate and late outcome may be compromised by acute thrombosis or the development of fibro-intimal hyperplasia. In addition, progression of coronary artery disease proximal or distal to the stent as well as in non-stented arteries is not uncommon. As a result, complications can occur, such as acute myocardial infarction, worsened heart failure or recurrence of angina. In a stent, restenosis can occur without symptoms or with atypical complaints rendering the clinical diagnosis difficult. Routine invasive angiography is not appropriate as a follow up tool due to associated risk and cost and the limited functional assessment. Exercise and pharmacologic stress testing are increasingly used to evaluate the myocardial function, perfusion and adequacy of revascularization. Information obtained by these techniques provide important clues regarding presence and severity of compromise in myocardial blood flow. Stress echocardiography can be performed in conjunction with exercise or dobutamine infusion. The diagnostic accuracy has been moderate, but the results provide excellent prognostic stratification. Adding myocardial contrast agents can improve imaging quality and allows assessment of both function and perfusion. Stress radionuclide myocardial perfusion imaging is an alternative to evaluate these patients. The extent and severity of wall motion and perfusion abnormalities observed during exercise or pharmacologic stress are predictors of survival and risk of cardiac events. According to current guidelines, stress echocardiography and radionuclide imaging are considered to have appropriate indication among patients after PCI who have cardiac symptoms and those who underwent incomplete revascularization. Stress testing is not recommended in asymptomatic patients, particularly early after revascularization, Coronary CT angiography is increasingly used and provides high sensitive for the diagnosis of coronary artery stenosis. Average sensitivity and specificity for the diagnosis of in stent stenosis in pooled data are 79% and 81%, respectively. Limitations include blooming artifacts and low feasibility in patients with small stents or thick struts. Anatomical and functional cardiac imaging modalities are corner stone for the assessment of patients after PCI and provide salient diagnostic and prognostic information. Current imaging techniques cans serve as gate keeper for coronary angiography, thus limiting the risk of invasive procedures to those who are likely to benefit from subsequent revascularization. The determination of which modality to apply requires careful identification of merits and limitation of each technique as well as the unique characteristic of each individual patient.

Keywords: coronary artery disease, stress testing, cardiac imaging, restenosis

Procedia PDF Downloads 130
2 Stent Surface Functionalisation via Plasma Treatment to Promote Fast Endothelialisation

Authors: Irene Carmagnola, Valeria Chiono, Sandra Pacharra, Jochen Salber, Sean McMahon, Chris Lovell, Pooja Basnett, Barbara Lukasiewicz, Ipsita Roy, Xiang Zhang, Gianluca Ciardelli

Abstract:

Thrombosis and restenosis after stenting procedure can be prevented by promoting fast stent wall endothelialisation. It is well known that surface functionalisation with antifouling molecules combining with extracellular matrix proteins is a promising strategy to design biomimetic surfaces able to promote fast endothelialization. In particular, REDV has gained much attention for the ability to enhance rapid endothelialization due to its specific affinity with endothelial cells (ECs). In this work, a two-step plasma treatment was performed to polymerize a thin layer of acrylic acid, used to subsequently graft PEGylated-REDV and polyethylene glycol (PEG) at different molar ratio with the aim to selectively promote endothelial cell adhesion avoiding platelet activation. PEGylate-REDV was provided by Biomatik and it is formed by 6 PEG monomer repetitions (Chempep Inc.), with an NH2 terminal group. PEG polymers were purchased from Chempep Inc. with two different chain lengths: m-PEG6-NH2 (295.4 Da) with 6 monomer repetitions and m-PEG12-NH2 (559.7 Da) with 12 monomer repetitions. Plasma activation was obtained by operating at 50W power, 5 min of treatment and at an Ar flow rate of 20 sccm. Pure acrylic acid (99%, AAc) vapors were diluted in Ar (flow = 20 sccm) and polymerized by a pulsed plasma discharge applying a discharge RF power of 200 W, a duty cycle of 10% (on time = 10 ms, off time = 90 ms) for 10 min. After plasma treatment, samples were dipped into an 1-(3-dimethylaminopropyl)-3- ethylcarbodiimide (EDC)/N-hydroxysuccinimide (NHS) solution (ratio 4:1, pH 5.5) for 1 h at 4°C and subsequently dipped in PEGylate-REDV and PEGylate-REDV:PEG solutions at different molar ratio (100 μg/mL in PBS) for 20 h at room temperature. Surface modification was characterized through physico-chemical analyses and in vitro cell tests. PEGylated-REDV peptide and PEG were successfully bound to the carboxylic groups that are formed on the polymer surface after plasma reaction. FTIR-ATR spectroscopy, X -ray Photoelectron Spectroscopy (XPS) and contact angle measurement gave a clear indication of the presence of the grafted molecules. The use of PEG as a spacer allowed for an increase in wettability of the surface, and the effect was more evident by increasing the amount of PEG. Endothelial cells adhered and spread well on the surfaces functionalized with the REDV sequence. In conclusion, a selective coating able to promote a new endothelial cell layer on polymeric stent surface was developed. In particular, a thin AAc film was polymerised on the polymeric surface in order to expose –COOH groups, and PEGylate-REDV and PEG were successful grafted on the polymeric substrates. The REDV peptide demonstrated to encourage cell adhesion with a consequent, expected improvement of the hemocompatibility of these polymeric surfaces in vivo. Acknowledgements— This work was funded by the European Commission 7th Framework Programme under grant agreement number 604251- ReBioStent (Reinforced Bioresorbable Biomaterials for Therapeutic Drug Eluting Stents). The authors thank all the ReBioStent partners for their support in this work.

Keywords: endothelialisation, plasma treatment, stent, surface functionalisation

Procedia PDF Downloads 274
1 A Rare Case of Dissection of Cervical Portion of Internal Carotid Artery, Diagnosed Postpartum

Authors: Bidisha Chatterjee, Sonal Grover, Rekha Gurung

Abstract:

Postpartum dissection of the internal carotid artery is a relatively rare condition and is considered as an underlying aetiology in 5% to 25% of strokes under the age of 30 to 45 years. However, 86% of these cases recover completely and 14% have mild focal neurological symptoms. Prognosis is generally good with early intervention. The risk quoted for a repeat carotid artery dissection in subsequent pregnancies is less than 2%. 36-year Caucasian primipara presented on postnatal day one of forceps delivery with tachycardia. In the intrapartum period she had a history of prolonged rupture of membranes and developed intrapartum sepsis and was treated with antibiotics. Postpartum ECG showed septal inferior T wave inversion and a troponin level of 19. Subsequently Echocardiogram ruled out post-partum cardiomyopathy. Repeat ECG showed improvement of the previous changes and in the absence of symptoms no intervention was warranted. On day 4 post-delivery, she had developed symptoms of droopy right eyelid, pain around the right eye and itching in the right ear. On examination, she had developed right sided ptosis, unequal pupils (Rt miotic pupil). Cranial nerve examination, reflexes, sensory examination and muscle power was normal. Apart from migraine, there was no medical or family history of note. In view of Horner’s on the right, she had a CT Angiogram and subsequently MR/MRA and was diagnosed with dissection of the cervical portion of the right internal carotid artery. She was discharged on a course of Aspirin 75mg. By 6 week post-natal follow up patient had recovered significantly with occasional episodes of unequal pupils and tingling of right toes which resolved spontaneously. Cervical artery dissection, including VAD and carotid artery dissection, are rare complications of pregnancy with an estimated annual incidence of 2.6–3 per 100,000 pregnancy hospitalizations. Aetiology remains unclear though trauma during straining at labour, underlying arterial disease and preeclampsia have been implicated. Hypercoagulable state during pregnancy and puerperium could also be an important factor. 60-90% cases present with severe headache and neck pain and generally precede neurological symptoms like ipsilateral Horner’s syndrome, retroorbital pain, tinnitus and cranial nerve palsy. Although rare, the consequences of delayed diagnosis and management can lead to severe and permanent neurological deficits. Patients with a strong index of suspicion should undergo an MRI or MRA of head and neck. Antithrombotic and antiplatelet therapy forms the mainstay of therapy with selected cases needing endovascular stenting. Long term prognosis is favourable with either complete resolution or minimal deficit if treatment is prompt. Patients should be counselled about the recurrence risk and possibility of stroke in future pregnancy. Coronary artery dissection is rare and treatable but needs early diagnosis and treatment. Post-partum headache and neck pain with neurological symptoms should prompt urgent imaging followed by antithrombotic and /or antiplatelet therapy. Most cases resolve completely or with minimal sequelae.

Keywords: postpartum, dissection of internal carotid artery, magnetic resonance angiogram, magnetic resonance imaging, antiplatelet, antithrombotic

Procedia PDF Downloads 70