8079 Antidiabetic Evaluation of Pig (Sus scrofa) Bile on Alloxan-Induced BALB/c Mice
Authors: John Lyndon C. Lunnay
Abstract:
This study discerns to evaluate the antidiabetic efficacy of pig bile on alloxan-induced BALB/c mice. The experimental animals were divided and selected using RCBD into 5 groups (n= 4): T1 (negative control), T2 (1ml/kg), T3 (2ml/kg), T4 (3ml/kg) and T5 (Glibenclamide). Hyperglycemia was induced by injecting 1% alloxan monohydrate intraperitoneally. A glucose tolerance test was performed using a 2g/kg glucose solution, and blood glucose levels were measured at different time intervals. 14 days of monitoring was also done to ensure effectivity and efficacy of the different treatments. Bodyweight was also determined. Results show that administration of treatments on test animals significantly reverted the blood glucose levels of mice in 60 minutes and 120 minutes using an oral glucose tolerance test. After 14 days of monitoring, normal blood glucose levels were seen significantly on T2 (1ml/kg), T3 (2ml/kg), T4 (3ml/kg), and T5 (Glibenclamide), which only suggests the efficacy of pig bile on lowering glucose levels on alloxan-induced diabetic mice. Bodyweight analysis shows no significant difference. Duncan’s multiple range test (DMRT) shows comparable efficacy and effectivity between T4 (3ml/kg) and T5 (Glibenclamide) on lowering BGL at different day and time intervals.Keywords: pig bile, BALB/c mice, blood glucose, Gllibenclamide
Procedia PDF Downloads 1488078 Effect of Radiation on Magnetohydrodynamic Two Phase Stenosed Arterial Blood Flow with Heat and Mass Transfer
Authors: Bhavya Tripathi, Bhupendra Kumar Sharma
Abstract:
In blood, the concentration of red blood cell varies with the arterial diameter. In the case of narrow arteries, red blood cells concentrate around the center of the artery and there exists a cell-free plasma layer near the arterial wall due to Fahraeus-Lindqvist effect. Due to non- uniformity of the fluid in the narrow arteries, it is preferable to consider the two-phase model of the blood flow. In the present article, coupled nonlinear differential equations have been developed for momentum, energy and concentration of two phase model of the blood flow assuming the Newtonian fluid in both central core and cell free plasma layer and the exact solutions have been found for the problem. For having an adequate insight into the stenosed arterial two-phase blood flow, major components of the flow as flow resistance, total flow rate, and wall shear stress have been estimated for different values of magnetic and radiation parameter. Results show that the increase in the effects of magnetic field decreases the velocity of both cores as well as plasma regions. This result can be helpful to control the blood flow in narrow arteries during surgical process. Temperature of core as well plasma regions decrease as value of radiation parameter increases. The present result is implemented in the form of radiation therapy which is very helpful for cancer patients.Keywords: two phase blood flow, radiation, magnetohydrodynamics (MHD), stenosis
Procedia PDF Downloads 2058077 Genetic Diversity of Cord Blood of the National Center of Blood Transfusion, Mexico (NCBT)
Authors: J. Manuel Bello-López, Julieta Rojo-Medina
Abstract:
Introduction: The transplant of Umbilical Cord Blood Units (UCBU) are a therapeutic possibility for patients with oncohaematological disorders, especially in children. In Mexico, 48.5% of oncological diseases in children 1-4 years old are leukemias; whereas in patients 5-14 and 15-24 years old, lymphomas and leukemias represent the second and third cause of death in these groups respectively. Therefore it is necessary to have more registries of UCBU in order to ensure genetic diversity in the country; the above because the search for appropriate a UCBU is increasingly difficult for patients of mixed ethnicity. Objective: To estimate the genetic diversity (polymorphisms) of Human Leucocyte Antigen (HLA) Class I (A, B) and Class II (DRB1) in UCBU cryopreserved for transplant at Cord Blood Bank of the NCBT. Material and Methods: HLA typing of 533 UCBU for transplant was performed from 2003-2012 at the Histocompatibility Laboratory from the Research Department (evaluated by Los Angeles Ca. Immunogenetics Center) of the NCBT. Class I HLA-A, HLA-B and Class II HLA-DRB1 typing was performed using medium resolution Sequence-Specific Primer (SSP). In cases of an ambiguity detected by SSP; Sequence-Specific Oligonucleotide (SSO) method was carried out. A strict analysis of populations genetic parameters were done in 5 representative UCBU populations. Results: 46.5% of UCBU were collected from Mexico City, State of Mexico (30.95%), Puebla (8.06%), Morelos (6.37%) and Veracruz (3.37%). The remaining UCBU (4.75%) are represented by other states. The identified genotypes correspond to Amerindian origins (HLA-A*02, 31; HLA-B*39, 15, 48), Caucasian (HLA-A*02, 68, 01, 30, 31; HLA-B*35, 15, 40, 44, 07 y HLA-DRB1*04, 08, 07, 15, 03, 14), Oriental (HLA-A*02, 30, 01, 31; HLA-B* 35, 39, 15, 40, 44, 07,48 y HLA-DRB1*04, 07,15, 03) and African (HLA-A*30 y HLA-DRB1*03). The genetic distances obtained by Cavalli-Sforza analysis of the five states showed significant genetic differences by comparing genetic frequencies. The shortest genetic distance exists between Mexico City and the state of Puebla (0.0039) and the largest between Veracruz and Morelos (0.0084). In order to identify significant differences between this states, the ANOVA test was performed. This demonstrates that UCBU is significantly different according to their origin (P <0.05). This is shown by the divergence between arms at the Dendogram of Neighbor-Joining. Conclusions: The NCBT provides UCBU in patients with oncohaematological disorders in all the country. There is a group of patients for which not compatible UCBU can be find due to the mixed ethnic origin. For example, the population of northern Mexico is mostly Caucasian. Most of the NCBT donors are of various ethnic origins, predominantly Amerindians and Caucasians; although some ethnic minorities like Oriental, African and pure Indian ethnics are not represented. The NCBT is, therefore, establishing agreements with different states of Mexico to promote the altruistic donation of Umbilical Cord Blood in order to enrich the genetic diversity in its files.Keywords: cord blood, genetic diversity, human leucocyte antigen, transplant
Procedia PDF Downloads 3828076 Comparison of Early Post-operative Outcomes of Cardiac Surgery Patients Who Have Had Blood Transfusion Based on Fixed Cut-off Point versus of Change in Percentage of Basic Hematocrit Levels
Authors: Khosro Barkhordari, Fateme Sadr, Mina Pashang
Abstract:
Back ground: Blood transfusion is one of the major issues in cardiac surgery patients. Transfusing patients based on fixed cut-off points of hemoglobin is the current protocol in most institutions. The hemoglobin level of 7- 10 has been suggested for blood transfusion in cardiac surgery patients. We aimed to evaluate if blood transfusion based on change in percentage of hematocrit has different outcomes. Methods: In this retrospective cohort study, we investigated the early postoperative outcome of cardiac surgery patients who received blood transfusions at Tehran Heart Center Hospital, IRAN. We reviewed and analyzed the basic characteristics and clinical data of 700 patients who met our exclusion and inclusion criteria. The two groups of blood transfused patients were compared, those who have 30-50 percent decrease in basal hematocrit versus those with 10 -29 percent decrease. Results: This is ongoing study, and the results would be completed in two weeks after analysis of the date. Conclusion: Early analysis has shown no difference in early post-operative outcomes between the two groups, but final analysis will be completed in two weeks. 1-Department of Anesthesiology and Critical Care, Tehran Heart Center, Tehran University of Medical Sciences, Tehran, IRAN 2- Department of Research, Tehran Heart Center, Tehran, IRAN Quantitative variables were compared using the Student t-test or the Mann‐Whitney U test, as appropriate, while categorical variables were compared using the χ2 or the Fisher exact test, as required. Our intention was to compare the early postoperative outcomes between the two groups, which include 30 days mortality, Length of ICU stay, Length of hospital stay, Intubation time, Infection rate, acute kidney injury, and respiratory complications. The main goal was to find if transfusing blood based on changes in hematocrit from a basal level was better than to fixed cut-off point regarding early post-operative outcomes. This has not been studied enough and may need randomized control trials.Keywords: post-operative, cardiac surgery, outcomes, blood transfusion
Procedia PDF Downloads 868075 The Study about the New Monitoring System of Signal Equipment of Railways Using Radio Communication
Authors: Masahiko Suzuki, Takashi Kato , Masahiro Kobayashi
Abstract:
In our company, the monitoring system for signal equipment has already implemented. So, we can know the state of signal equipment, sitting in the control room or the maintenance center. But this system was installed over 20 years ago, so it cannot stand the needs such as 'more stable operation', 'broadband data transfer', 'easy construction and easy maintenance'. To satisfy these needs, we studied the monitoring system using radio communication as a new method which can realize the operation in the terrible environment along railroads. In these studies, we have developed the terminals and repeaters based on the ZigBee protocol and have implemented the application using two different radio bands simultaneously. At last, we got the good results from the fundamental examinations using the developed equipment.Keywords: monitoring, radio communication, 2 bands, ZigBee
Procedia PDF Downloads 5888074 A Portable Device for Pulse Wave Velocity Measurements
Authors: Chien-Lin Wang, Cha-Ling Ko, Tainsong Chen
Abstract:
Pulse wave velocity (PWV) of blood flow provides important information of vessel property and blood pressure which can be used to assess cardiovascular disease. However, the above measurements need expensive equipment, such as Doppler ultrasound, MRI, angiography etc. The photoplethysmograph (PPG) signals are commonly utilized to detect blood volume changes. In this study, two infrared (IR) probes are designed and placed at a fixed distance from finger base and fingertip. An analog circuit with automatic gain adjustment is implemented to get the stable original PPG signals from above two IR probes. In order to obtain the time delay precisely between two PPG signals, we obtain the pulse transit time from the second derivative of the original PPG signals. To get a portable, wireless and low power consumption PWV measurement device, the low energy Bluetooth 4.0 (BLE) and the microprocessor (Cortex™-M3) are used in this study. The PWV is highly correlated with blood pressure. This portable device has potential to be used for continuous blood pressure monitoring.Keywords: pulse wave velocity, photoplethysmography, portable device, biomedical engineering
Procedia PDF Downloads 5278073 Impact of Financial Technology Growth on Bank Performance in Gulf Cooperation Council Region
Authors: Ahmed BenSaïda
Abstract:
This paper investigates the association between financial technology (FinTech) growth and bank performance in the Gulf Cooperation Council (GCC) region. Application is conducted on a panel dataset containing the annual observations of banks covering the period from 2012 to 2021. FinTech growth is set as an explanatory variable on three proxies of bank performance. These proxies are the return on assets (ROA), return on equity (ROE), and net interest margin (NIM). Moreover, several control variables are added to the model, including bank-specific and macroeconomic variables. The results are significant as all the proxies of the bank performance are negatively affected by the growth of FinTech startups. Consequently, banks are urged to proactively invest in FinTech startups and engage in partnerships to avoid the risk of disruption.Keywords: financial technology, bank performance, GCC countries, panel regression
Procedia PDF Downloads 788072 Evaluation of Knowledge and Acceptance of Food Irradiated by Individual from Food Bank of Brazil
Authors: Juliana Altavista Sagretti Gallo, Susy Frey Sabato
Abstract:
Despite the poverty in the world, a third of all food produced in the world is wasted. FAO, the United Nations Organization of Agriculture and Food, points out the need to combine actions and new technologies to combat hunger and waste in contrast to the high production of food in the world. The energy of ionizing radiation in food brought many positive results, such as increased validity and insect infestation control. The food banks are organizations that act at various points of the food chain to collect and distribute food to the needy. So, the aim of this study was to initiate a partnership between irradiation and the food bank through the development of a questionnaire to evaluate and disseminate the knowledge and acceptance of individuals in the food bank in Brazil. Also, this study aimed to standardize a basis questionnaire for future research assessment of irradiated foods. For the construction of the questionnaire as a measuring instrument, a comprehensive and rigorous literature review was made. It's covered qualitative research, questionnaires, sensory evaluation, and food irradiated. Three stages of pre - tests were necessary, and related fields of experts were consulted. As a result, the questionnaire has three parts, personal issues, assertive issues and questions of multiple choices and finally an informative question. The questionnaire was applied in Ceagesp food bank in the biggest center of food in Brazil. Conclusions. 30 % of participants of Ceagesp bank had already heard of the Food irradiation but did not know about the mechanism, so they rejected the idea to associate with radioactivity and danger. The video showed in the last question and application of the questionnaire disseminated the idea of security. All individuals declare understand the goal of treatment and accept buy and consume irradiated food after them.Keywords: bank of food, questionary, irradiated food, acceptance of irradiated food
Procedia PDF Downloads 3238071 An Examination of Business Ethics and Corporate Social Responsibility: A Case Study of Zenith Bank PLC Jalingo
Authors: Abubakar Mohammed Bakoji
Abstract:
The paper examine business ethics through it pursuit for corporate social responsibility to the society in which the business long existed, Zenith bank PLC was selected as case study for it longer period of its business in the state, in order to achieve the research objective of the paper which sought the following: i. To examine relationship between business ethics and corporate social responsibility in Zenith bank PLC Jalingo; ii. To establish whether or not such ethics statement that acclaim corporate social responsibility are adhere to by the Zenith bank PLC Jalingo; iii. To determine the benefit drive by the society on the corporate social responsibility of Zenith bank PLC Jalingo to the people of the state of their operation. The research was conducted using qualitative research design approach, where convenience sampling technique was adopted using semi structured interview to one of the key staff of Zenith bank PLC Jalingo and five other beneficiaries of Zenith bank PLC corporate social responsibility projects served as respondents. The data obtained was analyze using content analysis and the result of the findings revealed that Zenith bank PLC has a Good business ethics and they adhere to the ethics, that they have completed several viable projects to the state as their corporate social responsibility and the beneficiaries and the respondents beneficiaries has confirmed and have produced evidence of how the projects has assisted in stifle their hardship. Hence, business ethics has a significant relationship with corporate social responsibility in Zenith bank PLC Jalingo.Keywords: business ethics, Corporate Social Responsibility, Zenith Bank PLC, business ethics
Procedia PDF Downloads 4788070 E-Service and the Nigerian Banking Sector: A Review of ATM Architecture and Operations
Authors: Bashir Aliyu Yauri, Rufai Aliyu Yauri
Abstract:
With the introduction of cash-less society policy by the Central Bank of Nigeria, the concept of e-banking services has experienced a significant improvement over the years. Today quite a number of people are embracing e-banking activities especially ATM, thereby moving away from the conventional banking system. This paper presents a review of the underlying Architectural Layout of Intra-Bank and Inter-Bank ATM connectivity in Nigeria. The paper further investigates and discusses factors affecting the Intra-Bank and Inter-Bank ATM connectivity in Nigeria. And as well possible solutions to these factors affecting ATM Connectivity and Operations are proposed.Keywords: architectural layout, automated teller machine, e-services, postilion
Procedia PDF Downloads 6338069 Improving the Design of Blood Pressure and Blood Saturation Monitors
Authors: L. Parisi
Abstract:
A blood pressure monitor or sphygmomanometer can be either manual or automatic, employing respectively either the auscultatory method or the oscillometric method. The manual version of the sphygmomanometer involves an inflatable cuff with a stethoscope adopted to detect the sounds generated by the arterial walls to measure blood pressure in an artery. An automatic sphygmomanometer can be effectively used to monitor blood pressure through a pressure sensor, which detects vibrations provoked by oscillations of the arterial walls. The pressure sensor implemented in this device improves the accuracy of the measurements taken.Keywords: blood pressure, blood saturation, sensors, actuators, design improvement
Procedia PDF Downloads 4558068 Application of GPRS in Water Quality Monitoring System
Authors: V. Ayishwarya Bharathi, S. M. Hasker, J. Indhu, M. Mohamed Azarudeen, G. Gowthami, R. Vinoth Rajan, N. Vijayarangan
Abstract:
Identification of water quality conditions in a river system based on limited observations is an essential task for meeting the goals of environmental management. The traditional method of water quality testing is to collect samples manually and then send to laboratory for analysis. However, it has been unable to meet the demands of water quality monitoring today. So a set of automatic measurement and reporting system of water quality has been developed. In this project specifies Water quality parameters collected by multi-parameter water quality probe are transmitted to data processing and monitoring center through GPRS wireless communication network of mobile. The multi parameter sensor is directly placed above the water level. The monitoring center consists of GPRS and micro-controller which monitor the data. The collected data can be monitor at any instant of time. In the pollution control board they will monitor the water quality sensor data in computer using Visual Basic Software. The system collects, transmits and processes water quality parameters automatically, so production efficiency and economy benefit are improved greatly. GPRS technology can achieve well within the complex environment of poor water quality non-monitored, and more specifically applicable to the collection point, data transmission automatically generate the field of water analysis equipment data transmission and monitoring.Keywords: multiparameter sensor, GPRS, visual basic software, RS232
Procedia PDF Downloads 4128067 Dynamic Shock Bank Liquidity Analysis
Authors: C. Recommandé, J. C. Blind, A. Clavel, R. Gourichon, V. Le Gal
Abstract:
Simulations are developed in this paper with usual DSGE model equations. The model is based on simplified version of Smets-Wouters equations in use at European Central Bank which implies 10 macro-economic variables: consumption, investment, wages, inflation, capital stock, interest rates, production, capital accumulation, labour and credit rate, and allows take into consideration the banking system. Throughout the simulations, this model will be used to evaluate the impact of rate shocks recounting the actions of the European Central Bank during 2008.Keywords: CC-LM, Central Bank, DSGE, liquidity shock, non-standard intervention
Procedia PDF Downloads 4588066 Analysis on the Effectiveness of the "Three-Exemption" Policy Aimed at Promoting Unpaid Blood Donation in Zhejiang
Authors: Ni Tang, Jinping Zhang
Abstract:
An effective and sustainable volunteer team is needed to create a more available blood supply system. In order to promote the sustainable development of blood donation in Zhejiang Province, China, a “three-exemption” policy was proposed in 2014: blood donors who received the National Award for unpaid blood donation may government-invested and funded parks, scenic spots and other places for free, visit non-profit medical institutions for free outpatient fees, and be exempted from urban public transportation fees. As the policy has been in place for seven years, this study evaluated the effectiveness of the policy by comparing the increasing rate of blood donation in Hangzhou (capital city of Zhejiang) before and after the policy using the intermittent time series analysis. The blood donation in Anhui, a Province near Zhejiang, was also compared as a negative control. Blood donation data from 2012 to 2018 were obtained from the donation center's official websites. The increasing rate of blood donation volume since 2012 in Hangzhou is 34.37 units/month, and after 2014, the increasing rate additionally increases 71.69 (p=0.1442), which indicating a statistically non-significant change after the policy. While as a negative control, in Anhui, the increasing rate of blood donation volume since 2012 is -163.3 unit/month, and the increasing rate additionally increases 167.2 (p=5.63e-07) after 2014. The result shows that the three-exemption policy had a certain level of impact on encouraging volunteers to donate blood, but the effect was not substantial. One possible reason for the ineffectiveness of the policy might be a lack of public awareness of the policy. On the other hand, this policy mainly waived unnecessary life expenses, such as fares and scenic entrance fees, and requires a certain number of blood donations, registration procedures, and blood donation certificates. Perhaps, reducing life-related expenses such as oil, water and electricity, could better attract people to participate in blood donation. This current study on the three-exemption policy provides a new direction for promoting people's blood donation. Incentive policies may require greater publicity and incentives. In order to better ensure the operation of the blood donation system, other policies, especially incentive policies, should be further explored.Keywords: blood donation, policy, Zhejiang, unpaid blood donation, three-exemption policy
Procedia PDF Downloads 2098065 Impacts of Financial Development and Operational Scale on Bank Efficiencies in Taiwan
Authors: Ying-Hsiu Chen, Pao-Peng Hsu
Abstract:
This paper adopts a two-stage data envelopment analysis to explore the impacts of financial development and bank operational scale on bank efficiencies. The sample comprises of unbalanced panel data of 32 Taiwanese enlisted in domestic commercial banks over the period 1998 to 2013. Empirical results show that technical efficiency is positively related to financial development, whereas the effect of financial development on scale efficiency is insignificant. The effect of operational scale exerts a significantly positive effect on bank efficiencies, but the gain of efficiency is decreased gradually when operational scale increases. Furthermore, increase in capital adequacy ratio and market power of banks leads to a growth of bank efficiencies.Keywords: financial development, operational scale, efficiency, DEA
Procedia PDF Downloads 5258064 Engaging the World Bank: Good Governance and Human Rights-Based Approaches
Authors: Lottie Lane
Abstract:
It is habitually assumed and stated that the World Bank should engage and comply with international human rights standards. However, the basis for holding the Bank to such standards is unclear. Most advocates of the idea invoke aspects of international law to argue that the Bank has existing obligations to act in compliance with human rights standards. The Bank itself, however, does not appear to accept such arguments, despite having endorsed the importance of human rights for a considerable length of time. A substantial challenge is that under the current international human rights law framework, the World Bank is considered a non-state actor, and as such, has no direct human rights obligations. In the absence of clear legal duties for the Bank, it is necessary to look at the tools available beyond the international human rights framework to encourage the Bank to comply with human rights standards. This article critically examines several bases for arguing that the Bank should comply and engage with human rights through its policies and practices. Drawing on the Bank’s own ‘good governance’ approach as well as the United Nations’ ‘human rights-based-approach’ to development, a new basis is suggested. First, the relationship between the World Bank and human rights is examined. Three perspectives are considered: (1) the legal position – what the status of the World Bank is under international human rights law, and whether it can be said to have existing legal human rights obligations; (2) the Bank’s own official position – how the Bank envisages its relationship with and role in the protection of human rights; and (3) the relationship between the Bank’s policies and practices and human rights (including how its attitudes are reflected in its policies and how the Bank’s operations impact human rights enjoyment in practice). Here, the article focuses on two examples – the (revised) 2016 Environmental and Social Safeguard Policies and the 2012 case-study regarding Gambella, Ethiopia. Both examples are widely considered missed opportunities for the Bank to actively engage with human rights. The analysis shows that however much pressure is placed on the Bank to improve its human rights footprint, it is extremely reluctant to do so explicitly, and the legal bases available are insufficient for requiring concrete, ex ante action by the Bank. Instead, the Bank’s own ‘good governance’ approach to development – which it has been advocating since the 1990s – can be relied upon. ‘Good governance’ has been used and applied by many actors in many contexts, receiving numerous different definitions. This article argues that human rights protection can now be considered a crucial component of good governance, at least in the context of development. In doing so, the article explains the relationship and interdependence between the two concepts, and provides three rationales for the Bank to take a ‘human rights-based approach’ to good governance. Ultimately, this article seeks to look beyond international human rights law and take a governance approach to provide a convincing basis upon which to argue that the World Bank should comply with human rights standards.Keywords: World Bank, international human rights law, good governance, human rights-based approach
Procedia PDF Downloads 3598063 The Performance of Saudi Banking Industry 2000 -2011: Have the Banks Distinguished Themselves from One Another?
Authors: Bukhari M. S. Sillah, Imran Khokhar, Muhammad Nauman Khan
Abstract:
This paper studies the technical efficiency of Saudi banking sector using stochastic frontier model. A sample of 12 banks over the period 2000-2011 is selected to investigate their technical efficiencies in mobilizing deposits, producing investment and generating income. The banks are categorized as Saudi-owned banks, Saudi-foreign-owned banks and Islamic banks. The findings show some consistent pattern of these bank types; and there exist significant disparities among the banks in term of technical efficiency. The Banque Saudi Fransi stands out as a benchmark bank for the industry, and it is a Saudi-foreign owned bank type. The Saudi owned bank types have shown fluctuating performance during the period; and the Islamic bank types are no significantly different from Saudi-owned bank types.Keywords: technical efficiency, production frontier model, Islamic banking
Procedia PDF Downloads 4918062 Food Irradiation in the Third Sector Development and Validation of Questionnaire to Standard Measuring Instrument for Evaluation of Acceptance and Sensory Analysis of Irradiated Foods
Authors: Juliana Sagretti, Susy Sabato
Abstract:
Despite the poverty in the world, a third of all food produced in the world is wasted. FAO, the United Nations Organization of Agriculture and Food, points out the need to combine actions and new technologies to combat hunger and waste in contrast to the high production of food in the world. The energy of ionizing radiation in food brought many positive results, such as increased validity and insect infestation control. The food banks are organizations that act at various points of food chain to collect and distribute food to the needy. So, the aim of this study was to initiate a partnership between irradiation and the food bank through the development of a questionnaire to evaluate and disseminate the knowledge and acceptance of individuals in the food bank in Brazil. In addition, this study aimed to standardize a basis questionnaire for future research assessment of irradiated foods. For the construction of the questionnaire as a measuring instrument, a comprehensive and rigorous literature review was made. Its covered qualitative research, questionnaires, sensory evaluation and food irradiated. Three stages of pre - tests were necessary and related fields of experts were consulted. As a result, the questionnaire has three parts, personal issues, assertive issues and questions of multiple choices and finally an informative question. The questionnaire was applied in Ceagesp food bank in the biggest center of food in Brazil (data not shown).Keywords: food bank, food irradiation, food waste, sustainability
Procedia PDF Downloads 3278061 Expansion of Cord Blood Cells Using a Mix of Neurotrophic Factors
Authors: Francisco Dos Santos, Diogo Fonseca-Pereira, Sílvia Arroz-Madeira, Henrique Veiga-Fernandes
Abstract:
Haematopoiesis is a developmental process that generates all blood cell lineages in health and disease. This relies on quiescent haematopoietic stem cells (HSCs) that are able to differentiate, self renew and expand upon physiological demand. HSCs have great interest in regenerative medicine, including haematological malignancies, immunodeficiencies and metabolic disorders. However, the limited yield from existing HSC sources drives the global need for reliable techniques to expand harvested HSCs at high quality and sufficient quantities. With the extensive use of cord blood progenitors for clinical applications, there is a demand for a safe and efficient expansion protocol that is able to overcome the limitations of the cord blood as a source of HSC. StemCell2MAXTM developed a technology that enhances the survival, proliferation and transplantation efficiency of HSC, leading the way to a more widespread use of HSC for research and clinical purposes. StemCell2MAXTM MIX is a solution that improves HSC expansion up to 20x, while preserving stemness, when compared to state-of-the-art. In a recent study by a leading cord blood bank, StemCell2MAX MIX was shown to support a selective 100-fold expansion of CD34+ Hematopoietic Stem and Progenitor Cells (when compared to a 10-fold expansion of Total Nucleated Cells), while maintaining their multipotent differentiative potential as assessed by CFU assays. The technology developed by StemCell2MAXTM opens new horizons for the usage of expanded hematopoietic progenitors for both research purposes (including quality and functional assays in Cord Blood Banks) and clinical applications.Keywords: cord blood, expansion, hematopoietic stem cell, transplantation
Procedia PDF Downloads 2678060 The Amount of Organic Phosphates (Like DPG) Existing in Blood is Determining Factor of Mammal’s Bulk
Authors: Ramin Amirmardfar
Abstract:
Throughout Necessary oxygen should be supplied for all cells of a mammal at any moment through blood to make it possible remain alive all cells the mammal’s body. In case a mammal’s bulk is large, there is a farther distance between cells in different tissues and mammals’ heart. Therefore red blood cells in bulky mammal’s body should be capable of conveying oxygen to farther distances. To make it practical, oxygen should be glued red blood cells tenaciously. In other words, cohesion strength of oxygen to red blood cell of bulky mammal’s blood should be much more than the same of small mammal’s blood. In mammal’s bodies, the controlling factor of amount of cohesion of oxygen to red blood cell, are organic phosphates (like DPG). The less DPG in red blood cells of a mammal, the more cohesion of oxygen to red blood cell (at the same rate). As much as oxygen is glued more tenacious to red blood cells, oxygen could been carried to farther distance and as much as oxygen could be conveyed to farther points of heart, bulk of mammal could be larger at the same rate.Keywords: mammals size, animals size, organic phosphates, DPG, red blood cell, metabolism
Procedia PDF Downloads 3558059 Myomectomy and Blood Loss: A Quality Improvement Project
Authors: Ena Arora, Rong Fan, Aleksandr Fuks, Kolawole Felix Akinnawonu
Abstract:
Introduction: Leiomyomas are benign tumors that are derived from the overgrowth of uterine smooth muscle cells. Women with symptomatic leiomyomas who desire future fertility, myomectomy should be the standard surgical treatment. Perioperative hemorrhage is a common complication in myomectomy. We performed the study to investigate blood transfusion rate in abdominal myomectomies, risk factors influencing blood loss and modalities to improve perioperative blood loss. Methods: Retrospective chart review was done for patients who underwent myomectomy from 2016 to 2022 at Queens hospital center, New York. We looked at preoperative patient demographics, clinical characteristics, intraoperative variables, and postoperative outcomes. Mann-Whitney U test were used for parametric and non-parametric continuous variable comparisons, respectively. Results: A total of 159 myomectomies were performed between 2016 and 2022, including 1 laparoscopic, 65 vaginal and 93 abdominal. 44 patients received blood transfusion during or within 72 hours of abdominal myomectomy. The blood transfusion rate was 47.3%. Blood transfusion rate was found to be twice higher than the average documented rate in literature which is 20%. Risk factors identified were black race, preoperative hematocrit<30%, preoperative blood transfusion within 72 hours, large fibroid burden, prolonged surgical time, and abdominal approach. Conclusion: Preoperative optimization with iron supplements or GnRH agonists is important for patients undergoing myomectomy. Interventions to decrease intra operative blood loss should include cell saver, tourniquet, vasopressin, misoprostol, tranexamic acid and gelatin-thrombin matrix hemostatic sealant.Keywords: myomectomy, perioperative blood loss, cell saver, tranexamic acid
Procedia PDF Downloads 858058 Accounting as Economic and Religious Reality: Reveal Religious Values Through the Photographs in Annual Report of Islamic Bank
Authors: Rahasanica Nariswari Pratiwi, Maulana Syaiful Haq
Abstract:
The role of accounting in Islamic Banking is not only as economic reality but also as religious reality. Religious reality constructed by religious value in annual report of Islamic Bank. Thus, the purpose of this paper is to understand and analyze the existence of religious values by form of photographs in annual report, and to analyze the reason of religious values disclosure in annual report. Ontologically, this study is build on a belief that annual report is a communication media to show the ways Islamic Banks express adherence to sharia principle. The research has done by analyzing the photographs in annual report of Bank Syariah Mandiri (BSM), Bank Muamalat Indonesia (BMI), Bank Nasional Indonesia (BNI) Syariah, Bank Rakyat Indonesia (BRI) Syariah, and Bank Central Asia (BCA) Syariah in Indonesia. This study is qualitative research, was carried out within interpretive paradigm using semiotic approach. By employing semiotic analysis, this research showed that annual report of Islamic Bank in Indonesia contained religious value by the form of its photographs. The results of this study also show that photographs in annual report of Islamic Banks in this research contained religious values. Furthermore, this study concludes that Islamic banks actually expressed religious reality and make them different from the other bank’s annual report which focuses only on economic reality. This indicates Islamic Banks obidience existence about responsibility, not only to the stakeholders but also to the society and Allah.Keywords: Islamic banking, semiotics, accounting, annual report
Procedia PDF Downloads 4948057 The Impact of Access to Microcredit Programme on Women Empowerment: A Case Study of Cowries Microfinance Bank in Lagos State, Nigeria
Authors: Adijat Olubukola Olateju
Abstract:
Women empowerment is an essential developmental tool in every economy especially in less developed countries; as it helps to enhance women's socio-economic well-being. Some empirical evidence has shown that microcredit has been an effective tool in enhancing women empowerment, especially in developing countries. This paper therefore, investigates the impact of microcredit programme on women empowerment in Lagos State, Nigeria. The study used Cowries Microfinance Bank (CMB) as a case study bank, and a total of 359 women entrepreneurs were selected by simple random sampling technique from the list of Cowries Microfinance Bank. Selection bias which could arise from non-random selection of participants or non-random placement of programme, was adjusted for by dividing the data into participant women entrepreneurs and non-participant women entrepreneurs. The data were analyzed with a Propensity Score Matching (PSM) technique. The result of the Average Treatment Effect on the Treated (ATT) obtained from the PSM indicates that the credit programme has a significant effect on the empowerment of women in the study area. It is therefore, recommended that microfinance banks should be encouraged to give loan to women and for more impact of the loan to be felt by the beneficiaries the loan programme should be complemented with other programmes such as training, grant, and periodic monitoring of programme should be encouraged.Keywords: empowerment, microcredit, socio-economic wellbeing, development
Procedia PDF Downloads 3048056 Subcutan Isosulfan Blue Administration May Interfere with Pulse Oximetry
Authors: Esra Yuksel, Dilek Duman, Levent Yeniay, Sezgin Ulukaya
Abstract:
Sentinel lymph node biopsy (SLNB) is a minimal invasive technique with lower morbidity in axillary staging of breast cancer. Isosulfan blue stain is frequently used in SLNB and regarded as safe. The present case report aimed to report severe decrement in SpO2 following isosulfan blue administration, as well as skin and urine signs and inconsistency with clinical picture in a 67-year-old ,77 kg, ASA II female case that underwent SLNB under general anesthesia. Ten minutes after subcutaneous administration of 10 ml 1% isosulfan blue by the surgeons into the patient, who were hemodynamically stable, SpO2 first reduced to 87% from 99%, and then to 75% in minutes despite 100% oxygen support. Meanwhile, blood pressure and EtCO2 monitoring was unremarkable. After specifying that anesthesia device worked normally, airway pressure did not increase and the endotracheal tube has been placed accurately, the blood sample was taken from the patient for arterial gas analysis. A severe increase was thought in MetHb concentration since SpO2 persisted to be 75% although the concentration of inspired oxygen was 100%, and solution of 2500 mg ascorbic acid in 500 ml 5% Dextrose was given to the patient via intravenous route until the results of arterial blood gas were obtained. However, arterial blood gas results were as follows: pH: 7.54, PaCO2: 23.3 mmHg, PaO2: 281 mmHg, SaO2: %99, and MetHb: %2.7. Biochemical analysis revealed a blood MetHb concentration of 2%.However, since arterial blood gas parameters were good, hemodynamics of the patient was stable and methemoglobin concentration was not so high, the patient was extubated after surgery when she was relaxed, cooperated and had adequate respiration. Despite the absence of respiratory or neurological distress, SpO2 value was increased only up to 85% within 2 hours with 5 L/min oxygen support via face mask in the surgery room as the patient was extubated. At that time, the skin of particularly the upper part of her body has turned into blue, more remarkable on the face. The color of plasma of the blood taken from the patient for biochemical analysis was blue. The color of urine coming throughout the urinary catheter placed in intensive care unit was also blue. Twelve hours after 5 L/min. oxygen inhalation via a mask, the SpO2 reached to 90%. During monitoring in intensive care unit on the postoperative 1st day, facial color and urine color of the patient was still blue, SpO2 was 92%, and arterial blood gas levels were as follows: pH: 7.44, PaO2: 76.1 mmHg, PaCO2: 38.2 mmHg, SaO2: 99%, and MetHb 1%. During monitoring in clinic on the postoperative 2nd day, SpO2 was 95% without oxygen support and her facial and urine color turned into normal. The patient was discharged on the 3rd day without any problem.In conclusion, SLNB is a less invasive alternative to axillary dissection. However, false pulse oximeter reading due to pigment interference is a rare complication of this procedure. Arterial blood gas analysis should be used to confirm any fall in SpO2 reading during monitoring.Keywords: isosulfan blue, pulse oximetry, SLNB, methemoglobinemia
Procedia PDF Downloads 3158055 Evaluation of the Safety and Performance of Blood Culture Practices Using BD Safety-Lokᵀᴹ Blood Collection Sets in the Emergency Room
Authors: Jeonghyun Chang, Taegeun Lee, Heungsup Sung, Yoon-Seon Lee, Youn-Jung Kim, Mi-Na Kim
Abstract:
Background: Safety device has been applied to improve safety and performance of blood culture practice. BD vacutainer® Safety-Lokᵀᴹ blood collection sets with pre-attached holder (Safety-Lok) (BD, USA) was evaluated in the emergency room (ER) of a tertiary care hospital. Methods: From April to June 2017, interns and nurses in ER were surveyed for blood culture practices with a questionnaire before and after 2 or 3 weeks of experience of Safety-Lok. All of them participated in exercise workshop for 1 hour combined with video education prior to the initial survey. The blood volume, positive and contamination rates of Safety-Lok-drawn (SD) blood cultures were compared to those of overall blood cultures. Results: Eighteen interns and 30 nurses were enrolled. As a result of the initial survey, interns had higher rates of needlestick incidence (27.8%), carriage of the blood-filled syringe with needle (88.9%) and lower rates of vacutainer use (38.9%) than nurses (13.3%, 53.3%, and 60.0%). Interns preferred to use safety devices (88.9%) rather than nurses (40.0%). The number of overall blood cultures and SD blood cultures was 9,053 and 555, respectively. While the overall blood volume of aerobic bottles was 2.6±2.1 mL, those of SD blood cultures were 5.0±3.0 mL in aerobic bottles and 6.0±3.0 mL in anaerobic bottles. Positive and contamination rates were 6.5% and 0.72% with SD blood cultures and 6.2% and 0.3% with overall blood cultures. Conclusions: The introduction of the safety device would encourage healthcare workers to collect adequate blood volume as well as lead to safer practices in the ER.Keywords: blood culture, needlestick, safety device, volume
Procedia PDF Downloads 2078054 Microfluidic Method for Measuring Blood Viscosity
Authors: Eunseop Yeom
Abstract:
Many cardiovascular diseases, such as thrombosis and atherosclerosis, can change biochemical molecules in plasma and red blood cell. These alterations lead to excessive increase of blood viscosity contributing to peripheral vascular diseases. In this study, a simple microfluidic-based method is used to measure blood viscosity. Microfluidic device is composed of two parallel side channels and a bridge channel. To estimate blood viscosity, blood samples and reference fluid are separately delivered into each inlet of two parallel side channels using pumps. An interfacial line between blood samples and reference fluid occurs by blocking the outlet of one side-channel. Since width for this interfacial line is determined by pressure ratio between blood and reference flows, blood viscosity can be estimated by measuring width for this interfacial line. This microfluidic-based method can be used for evaluating variations in the viscosity of animal models with cardiovascular diseases under flow conditions.Keywords: blood viscosity, microfluidic chip, pressure, shear rate
Procedia PDF Downloads 3718053 Numerical Analysis of Core-Annular Blood Flow in Microvessels at Low Reynolds Numbers
Authors: L. Achab, F. Iachachene
Abstract:
In microvessels, red blood cells (RBCs) exhibit a tendency to migrate towards the vessel center, establishing a core-annular flow pattern. The core region, marked by a high concentration of RBCs, is governed by significantly non-Newtonian viscosity. Conversely, the annular layer, composed of cell-free plasma, is characterized by Newtonian low viscosity. This property enables the plasma layer to act as a lubricant for the vessel walls, efficiently reducing resistance to the movement of blood cells. In this study, we investigate the factors influencing blood flow in microvessels and the thickness of the annular plasma layer using a non-miscible fluids approach in a 2D axisymmetric geometry. The governing equations of an incompressible unsteady flow are solved numerically through the Volume of Fluid (VOF) method to track the interface between the two immiscible fluids. To model blood viscosity in the core region, we adopt the Quemada constitutive law which is accurately captures the shear-thinning blood rheology over a wide range of shear rates. Our results are then compared to an established theoretical approach under identical flow conditions, particularly concerning the radial velocity profile and the thickness of the annular plasma layer. The simulation findings for low Reynolds numbers, demonstrate a notable agreement with the theoretical solution, emphasizing the pivotal role of blood’s rheological properties in the core region in determining the thickness of the annular plasma layer.Keywords: core-annular flows, microvessels, Quemada model, plasma layer thickness, volume of fluid method
Procedia PDF Downloads 568052 Corporate Governance and Bank Performance: A Study on Indian Banks
Authors: Arjun S.
Abstract:
This study examines the impact of corporate governance on financial performance of Indian banks during five years (from 2010 to 2015). Based on 218 observations, a quantitative method of data analysis was employed to investigate the relevance of corporate governance mechanisms. The first finding reveals a significant and negative impact of board size on the performance of Indian banks. The research also finds a significant and negative relationship between CEO duality and bank performance. Finally, the correlation results reveal that there is a significant and negative correlation of Bank size and bank performance.Keywords: Indian banks, financial performance, corporate governance, banksize
Procedia PDF Downloads 3568051 The Foundation of Islamic Center of Thailand Made Valuable Contributions to Thai Society
Authors: Tosaporn Mahamud
Abstract:
The foundation of the Islamic center of Thailand plays a vital role in order to bring diverse Muslim communities in a common place. The center itself is a bridge between Muslims in Thailand and Islamic world. The operational task of the center runs by many organizations through the funds and funds use for different activities for empowerment of Thai society in general and Muslim community in particular. This paper aims to focus on the role of the foundation of the Islamic center of Thailand to the Thai society. This paper also finds out the historical background of the center in term of building structure and design and functions.Keywords: design, empowerment, islamic, society
Procedia PDF Downloads 3728050 Performance Evaluation of the CSAN Pronto Point-of-Care Whole Blood Analyzer for Regular Hematological Monitoring During Clozapine Treatment
Authors: Farzana Esmailkassam, Usakorn Kunanuvat, Zahraa Mohammed Ali
Abstract:
Objective: The key barrier in Clozapine treatment of treatment-resistant schizophrenia (TRS) includes frequent bloods draws to monitor neutropenia, the main drug side effect. WBC and ANC monitoring must occur throughout treatment. Accurate WBC and ANC counts are necessary for clinical decisions to halt, modify or continue clozapine treatment. The CSAN Pronto point-of-care (POC) analyzer generates white blood cells (WBC) and absolute neutrophils (ANC) through image analysis of capillary blood. POC monitoring offers significant advantages over central laboratory testing. This study evaluated the performance of the CSAN Pronto against the Beckman DxH900 Hematology laboratory analyzer. Methods: Forty venous samples (EDTA whole blood) with varying concentrations of WBC and ANC as established on the DxH900 analyzer were tested in duplicates on three CSAN Pronto analyzers. Additionally, both venous and capillary samples were concomitantly collected from 20 volunteers and assessed on the CSAN Pronto and the DxH900 analyzer. The analytical performance including precision using liquid quality controls (QCs) as well as patient samples near the medical decision points, and linearity using a mix of high and low patient samples to create five concentrations was also evaluated. Results: In the precision study for QCs and whole blood, WBC and ANC showed CV inside the limits established according to manufacturer and laboratory acceptability standards. WBC and ANC were found to be linear across the measurement range with a correlation of 0.99. WBC and ANC from all analyzers correlated well in venous samples on the DxH900 across the tested sample ranges with a correlation of > 0.95. Mean bias in ANC obtained on the CSAN pronto versus the DxH900 was 0.07× 109 cells/L (95% L.O.A -0.25 to 0.49) for concentrations <4.0 × 109 cells/L, which includes decision-making cut-offs for continuing clozapine treatment. Mean bias in WBC obtained on the CSAN pronto versus the DxH900 was 0.34× 109 cells/L (95% L.O.A -0.13 to 0.72) for concentrations <5.0 × 109 cells/L. The mean bias was higher (-11% for ANC, 5% for WBC) at higher concentrations. The correlations between capillary and venous samples showed more variability with mean bias of 0.20 × 109 cells/L for the ANC. Conclusions: The CSAN pronto showed acceptable performance in WBC and ANC measurements from venous and capillary samples and was approved for clinical use. This testing will facilitate treatment decisions and improve clozapine uptake and compliance.Keywords: absolute neutrophil counts, clozapine, point of care, white blood cells
Procedia PDF Downloads 94